You are on page 1of 4

DYNAMO AMPERE CHECK REPORT

PT.KOLON INA MAKER : DINAMO AMPERE V, ) MANDO KOREA

DATE INSPECTOR

6/11/2012 HASAN DJ

ITEM NAME

( NEW______, REPAIR______ )

1. SPEC' & CAPACITY : __2,5_____KW ( at DC 12 2. CONNECTION DWG


1) TERMINAL CABLE CONNECTION

B E

3. RESISTANCE ( )
L(+)R(-) OL L(-)R(+) B(-)E(+) B(+)E(-) 6,0 M 1,8 M OL REMARK

4. DIODE TEST
B(-) E(+) B(+) OL E(-) REMARK

0,81 V DIGITAL MULTITESTER : KYORITSU 1009

4. INSULATION RESISTANCE TEST


B -E REMARK E: earth parts, 500M _________NOT GOOD

MAGGER TESTER : YOKOGAWA 3213A

5. CABLE LEAD LINE & TERMINAL CONDITION ? : __________GOOD, 6. ATTACHED SHEET


1) SUPPLIER CHECK SHEET ? ________________________ 2) KOLON INA DOCUMENTS ? ________________________ 3) OTHERS ? ______________

6. NOTE

FINAL RESULT
ACCEPT NOT ACCEPT
ISSUED AGREED ACCEPTED

DYNAMO STARTER CHECK REPORT


PT.KOLON INA MAKER : DINAMO AMPERE V, ) MANDO KOREA

DATE INSPECTOR

6/11/2012 HASAN DJ

ITEM NAME

( NEW______, REPAIR______ )

1. SPEC' & CAPACITY : __2,5_____KW ( at DC 12 2. CONNECTION DWG


1) TERMINAL CABLE CONNECTION

B E

3. RESISTANCE ( )
L(+)R(-) OL L(-)R(+) B(-)E(+) B(+)E(-) 6,0 M 1,8 M OL REMARK

4. DIODE TEST
B(-) E(+) B(+) OL E(-) REMARK

0,81 V DIGITAL MULTITESTER : KYORITSU 1009

4. INSULATION RESISTANCE TEST


B -E REMARK E: earth parts, 500M _________NOT GOOD

MAGGER TESTER : YOKOGAWA 3213A

5. CABLE LEAD LINE & TERMINAL CONDITION ? : __________GOOD, 6. ATTACHED SHEET


1) SUPPLIER CHECK SHEET ? ________________________ 2) KOLON INA DOCUMENTS ? ________________________ 3) OTHERS ? ______________

6. NOTE

FINAL RESULT
ACCEPT NOT ACCEPT
ISSUED AGREED ACCEPTED