Caps & Bases

LCB/CB Column Bases


MATERIAL: See table FINISH: LCB, CB44, CB46, CB48, CB66, CB68, CB610, CB86galvanized; all other CBSimpson Strong-Tie gray paint or HDG. Some models available in HDG or stainless steel INSTALLATION: Use all specified fasteners. See General Notes. For full loads, minimum side cover required is 3" for CB, 2" for LCB. Install all models with bottom of base plate flush with concrete. Post bases do not provide adequate resistance to prevent members from rotating about the base and therefore are not recommended for non top-supported installations (such as fences or unbraced carports). OPTIONS: LCB and CB are available in rough size. Other sizes available for CB specify W1 and W2 dimensions. Consult Simpson Strong-Tie for bolt sizes and allowable loads. CODES: See page 20 for Code Reference Key Chart.
1" for " Bolts 1" for " Bolts
For " Bo For lts " Bo lts

Caps & Bases

CB44 (CB46, CB48, CB64, CB66, CB68, CB86, CB88, CB610 similar)

Configuration of all other CB sizes

These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.

Model No. LCB44 CB44 LCB46 CB46 CB48 CB5-4.5 CB5-6 LCB66 CB64 CB66 CB6-7
C-2011 2011 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/10

Material Dimensions Nominal Column Strap Base D Size (Ga x Width) (Ga) W1 W2 4x4 4x4 4x6 4x6 4x8 GLULAM GLULAM 6x6 6x4 6x6 6x PSL PSL PSL 6x8 6x8 GLULAM GLULAM GLULAM 8x6 8x8 GLULAM GLULAM GLULAM 10x10 10x12 12x12 12 ga x 2 7 ga x 2 12 ga x 2 7 ga x 2 7 ga x 2 7 ga x 3 7 ga x 3 12 ga x 2 7 ga x 3 7 ga x 3 7 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 7 ga x 3 7 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 3 ga x 3 16 7 16 7 7 7 7 16 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 3 3 3 3 916 3 916 3 16 3 916 412 6 512 512 512 512 718 718 718 512 512 6 712 9116 712 712 6 712 9 9 2
1 9

Column Fasteners Allowable Uplift Loads Nails Machine Bolts Qty. Dia. 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
1

Nails (160) 2705 2705 2705

Bolts (160) 4250 4200 4240 4200 4200 4200 4200 4230 4200 4200 4200 6650 6650 6650 4200 4200 6650 6650 6650 6650 6650 6650 6650 6650 6650 6650 6650 6650 6650

Code Ref.

312 512 5 2 712 518 518 512 3 916 512 7 312 512 7 712 912 634 634 634 512 712 834 834 8 4 9 2
1 3 1

612 12-16d 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 612 12-16d

2 2

3 916 3 916

5 1

8 8 8 8 8 2 8 8 8 4 4 4

5 5 5 5 1

IL8

512 12-16d

5 5 5

170 IL8

CB7 18 -4 CB7 18 -6 CB7 18 -7 CB68 CB610 CB7-6 CB7-7.5 CB7-9 CB86 CB88 CB9-6 CB9-7.5 CB9-9 CB1010 CB1012 CB1212

3 3 3 5 5

LCB
170
For " B o For lts " B olts

8 8 4 4 4 4 4 4 4 4 4 4 4 4 4

3 3 3 3 3 3 3 3 3 3 3 3 3

IL8

CB7-10.5 GLULAM

10 916 634

170
3" Min. Side Cover 3" Min. Side Cover

CB9-10.5 GLULAM

1012 834 912 1112 1112 1112

IL8

CB9
(CB5, CB7 similar) for Glulam Column

1. Uplift loads have been increased for wind or earthquake with no further increase allowed; reduce where other loads govern. 2. PSL is parallel strand lumber. 3. LCB products may be installed with either bolts OR nails (not both) to achieve table loads. 4. Structural composite lumber columns have sides that show either the wide face or the edges of the lumber strands/veneers. Values in the tables reflect installation into the wide face. See technical bulletin T-SCLCOLUMN for values on the narrow face (edge) (see page 215 for details). LCB bases installed with nails must be installed into the wide face. 5. Designer is responsible for concrete design. 6. See pages 210-211 for common post allowable loads. 7. NAILS: 16d = 0.162" dia. x 312" long. See page 24-25 for other nail sizes and information.

63