You are on page 1of 12

Software Release Notes

Software Versions: 3.2.41


3.2.325 Embedded Software Portal Software

P/N 260-668060-001 Rev 021 20 January 2006

Copyright 2006 by Stratex Networks. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Stratex Networks.

DISCLAIMER Stratex Networks makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties or merchantability or fitness for any particular purpose. Further, Stratex Networks reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Stratex Networks to notify any person of such revision or changes.

TECHNICAL SUPPORT If you require technical assistance or if you have discovered a product issue, please contact the Technical Help Desk nearest to you as soon as possible. Their contact details are shown below:

Hamilton, Scotland

San Jose, USA Clark, Philippines

San Jose, CA Stratex Networks 120 Rose Orchard Way San Jose, California 95134 -1358 U.S.A.
1800 3629 283 (US Based) +1 408 944 3602 (English) +1 408 944 3564 (Spanish)
Americas_Help@stratexnet.com

United Kingdom Stratex Networks 4 Bell Drive Hamilton International Technology Park Blantyre, Scotland, G72 0FB UNITED KINGDOM
+44 1698 717 230
EMEA_Help@stratexnet.com

Philippines Stratex Networks Bldg 10 Unit B, Philexcel Industrial Park Clark Special Economic Zone Clark Field Pampanga PHILIPPINES
+63 45 599 5192
Asia_Help@stratexnet.com

ii

Table of Contents
Scope and Purpose .......................................................................................................................................................1 Software Introduction .....................................................................................................................................................1 Supported Functionality .................................................................................................................................................2 Compatibility ..................................................................................................................................................................4
Eclipse Hardware Supported ..............................................................................................................................4 Operating Systems Supported............................................................................................................................6 Computer Hardware Supported ..........................................................................................................................6 Regional Settings Supported ..............................................................................................................................7

Closed Field Issues........................................................................................................................................................7 Closed Significant Issues ...............................................................................................................................................8 Portal and Embedded Compatibility History...................................................................................................................8 Important Notes .............................................................................................................................................................8

iii

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Scope and Purpose


This document provides software release information on supported functionality, compatibility, and known customer affecting issues, relating to the released software versions. The intended users of this document are: Stratex Networks (SN) Customers SN Value Added Resellers SN Value Added Service Providers SN Product Support staff SN Field Service staff

Software Introduction
This software has been made available for customer release. In addition to previously supported hardware and functionality it now provides additional support for: IDU 300 155o 1+1 DAC 3xE3/DS3M ODU 300 SP Additional ODU 300 HP frequencies Additional RAC 40, RAC 3X, IDU 300 ES +8xE1 capacities DAC ES/GE priority mapping, transport channel and VLAN tagging Customer naming of system functions Software rollback and reset Network time protocol Event Log and Link History clear down Improved Protection Diagnostics diagram Alarm action severity thresholds Default gateway support

The following table lists the software details for this release. Product Eclipse Embedded Software Eclipse Portal Software Part Number 275-250219-030241 280-200010-0302325 Version Number 3.2.41 3.2.325 Stratex Reference Number 1341-063 0184-069

This release is supported by ProVision Element Manager System software version 5.6.1 with the following exceptions: Some IDU300 155o 1+1 or DAC 3xE3/DS3M events will not be processed ODU 300 SP bulk software download is not supported and RF values are not displayed in the configuration viewer

P/N 260-668060-001 Rev 021, 20 January 2006

Page 1

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Supported Functionality
The following headings list functionality that is currently supported by 3.2.41 embedded and 3.2.325 Portal software. New functionality is highlighted in bold italics.

Configuration
Populate information fields such as terminal name, site name, etc View expected plug-in layout Configure frequency, power, modulation and capacity Configure tributary interface parameters Configure DAC ES ports Configure circuits Configure IP routing Set radio date and time Manage software versions and download View active license and download license Configure ring protection Configure dynamic routing View equipment part numbers and serial numbers Configure custom T/R splits Configure trap destinations Configure XP4 compatibility mode Configure ring wrap and unwrap criteria Configure system function names

Performance and Monitoring


View RSL View G.826 15-minute and daily registers View history graphs and reports View Real time G.826 View event log and view event history View temperature values View forward power data View available supply voltages View DAC ES Ethernet performance statistics Estimated BER (G.821) performance monitor for link history reports

Diagnostics
Activate tributary/AUX line facing loop back Activate tributary/AUX radio facing loop back Activate digital loop back Activate IF loop back Activate circuit loopbacks Transmit AIS on individual tributaries Enable TX PA mute View system summary View problem and severity indicators Disable ATPC Enable DAC PRBS Configure safety timers View and control ring status PRBS tester reset control Perform software rollback and reset Clear event log
P/N 260-668060-001 Rev 021, 20 January 2006 Page 2

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Protection Support
Equipment protection supported Hitless path protection supported Unidirectional ring protection supported Optical tributary protection supported

Communications & Networking


Serial interface supported SNMPv2 interface supported Ethernet interface support NMS overhead channel supported Static routing supported OSPF routing supported RIP II routing supported Configure default gateway

Miscellaneous Features
Manufacturing details supported Watch dog supported ATPC supported Portal auto-version supported (upload Portal from radio) Soft reset without interrupting traffic As-built report supported Data file to send to Stratex Help Desk

Alarms
Alarm hierarchy supported User configurable alarm thresholds Alarm I/O supported

Logs
Event log operational Informational event log entries Event log notes

Security
Features controlled by license key Portal user security Auto-login support for ProVision

Software Loading
Software loading internal users only Software loading customer usable

Portal Help
Customer support details About Eclipse Portal Eclipse Help integration with alarm troubleshooting entries

P/N 260-668060-001 Rev 021, 20 January 2006

Page 3

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Compatibility
Eclipse Hardware Supported
The following table details the hardware that is supported by this software and corresponding part numbers. Hardware Type
IDC NCC FAN INU INUe NPC IDU 100 8x IDU 100 16x IDU 100 20x IDU 300 8x IDU 300 20x IDU 300 ES AUX DAC 4x DAC 16x DAC 155o DAC 155oM DAC ES DAC GE DAC 2x155e DAC 3xE3/DS3 RAC 10 RAC 10 v2 RAC 30 RAC 40 RAC 3X

Part Number
EXC-001, EXC-002 EXN-001, EXN-002 EXF-001, EXF-002 EXX-000-001, EXX-000-002 EXX-000-201 EXS-001 EXB-081-001 EXB-161-001 EXB-201-001 EXG-081-001 EXG-201-001 EXG-211-001 EXA-001 EXD-040-001 EXD-160-001 EXD-152-001 EXD-153-001 EXD-171-001 EXD-180-001 EXD-254-001 EXD-330-001 EXR-011-001 EXR-011-002 EXR-999-001, EXR-999-002 EXR-966-001 EXR-900-001

Description
Indoor Chassis, 1RU Node Controller Card Fan Card Intelligent Node Unit, 1RU Intelligent Node Unit, Extended Node Protection Card Indoor Unit, 8xE1, QPSK Indoor Unit, 16xE1, QPSK Indoor Unit, 20xE1, Hot Standby Indoor Unit, 8xE1/DS1 Indoor Unit, 20xE1/DS1, Hot Standby Indoor Unit, Fast Ethernet + 8xE1/DS1 Auxiliary and alarm I/O card Data Access Card, 4xE1/DS1 Data Access Card, 16xE1/DS1 Data Access Card, 1xSTM-1/OC3, Optical Data Access Card, 1xSTM-1/OC3 Multiplexed to 63E1/84DS1, Optical Data Access Card, 10/100baseT Fast Ethernet Data Access Card, Gigabit Ethernet Data Access Card, 2xSTM-1/OC3, Electrical Data Access Card, 3xE3/DS3, tributary protection Radio Access Card, ODU 100 Radio Access Card, ODU 100 version 2 Radio Access Card, ODU 300 Radio Access Card, ODU 300, 64xE1, 1xSTM-1/OC3, XPIC Radio Access Card, ODU 300, 1xSTM1/OC3 and 2xSTM1/OC3

P/N 260-668060-001 Rev 021, 20 January 2006

Page 4

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Hardware Type
ODU 100

Part Number
ECS-07-0154-* ECS-08-0119-* ECS-08-0266-* ECS-11-0490-* ECS-13-0266-* ECS-15-0490-* ECS-18-0340-* ECS-23-0600-* ECS-23-1232-* ECS-31-0410-* ECS-31-1008-* ECS-38-1260-* E**-05-0300-* E**-06-0160-* E**-07-0154-* E**-07-0196-* E**-08-0126-* E**-08-0266-* E**-08-0311-* E**-11-0530-* E**-15-0420-* E**-15-0644-* E**-18-1008-* E**-18-1120-* E**-23-1008-* E**-26-0800-* E**-28-0450-* E**-31-1975-* E**-38-1000-* EAH-06-0252-* EAH-06-0180-* EAH-07-0161-* EAH-08-0126-* EAH-08-0266-* EAH-08-0311-* EAH-11-0530-* EAH-15-0475-* EAH-15-0728-* EAH-18-1092-* EAH-23-0600-* EAH-23-1232-* ECS-07-0161-* ECS-08-0126-* ECS-08-0311-* ECS-11-0500-* ECS-15-0315-* ECS-15-0644-* ECS-18-1010-* ECS-23-1008-* ECS-26-1008-* ECS-31-0450-* ECS-31-1975-* E**-05-0312-* E**-06-0170-* E**-07-0161-* E**-07-0245-* E**-08-0151-* E**-08-0305-* E**-11-0490-* E**-13-0266-* E**-15-0475-* E**-15-0728-* E**-18-1010-* E**-18-1560-* E**-23-1200-* E**-26-0855-* E**-28-1008-* E**-32-0812-* E**-38-1260-* EAH-06-0160-* EAH-06-0340-* EAH-07-0245-* EAH-08-0152-* EAH-08-0306-* EAH-11-0490-* EAH-15-0315-* EAH-15-0490-* EAH-18-0340-* EAH-18-1120-* EAH-23-1008-* ECS-07-0245-* ECS-08-0151-* ECS-08-0305-* ECS-11-0530-* ECS-15-0420-* ECS-15-0728-* ECS-18-1092-* ECS-23-1200-* ECS-31-0225-* ECS-31-0490-* ECS-32-0812-* E**-06-0252-* E**-06-0340-* E**-07-0168-* E**-08-0119-* E**-08-0208-* E**-08-0310-* E**-11-0500-* E**-15-0315-* E**-15-0490-* E**-18-0340-* E**-18-1092-* E**-23-0600-* E**-23-1232-* E**-26-1008-* E**-31-0225-* E**-38-0700-* EAH-06-0170-* EAH-07-0154-* EAH-08-0119-* EAH-08-0208-* EAH-08-0310-* EAH-11-0500-* EAH-15-0420-* EAH-15-0644-* EAH-18-1010-* EAH-18-1560-* EAH-23-1200-*

Description
Frequency bands supported are: 7, 8, 11, 13, 15, 18, 23, 26, 31, 32, 38 GHz
Note: the software supports these frequency bands/splits however the hardware option may not exist.

* All numbers supported

ODU 300 EP & SP

Frequency bands supported are: 5, 6, 7, 8, 11, 13, 15, 18, 23, 26, 28, 31, 32, 38 GHz
Note: the software supports these frequency bands/splits however the hardware option may not exist.

* All numbers & letters supported

ODU 300 HP

Frequency bands supported are: 6, 7, 8, 11, 15, 18, 23 GHz


Note: the software supports these frequency bands/splits however the hardware option may not exist.

* All numbers supported

P/N 260-668060-001 Rev 021, 20 January 2006

Page 5

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Operating Systems Supported


The following table details the supported Operating Systems. Operating System Windows XP Pro (SP1) Windows 2000 Pro (SP3) Windows NT 4.0 Windows 98 Notes Refer to Eclipse User Manual for XP support information -

Computer Hardware Supported


The following table details the minimum hardware specifications required to operate Portal. Attributes Processor RAM HD space (install and operate) Monitor adaptor Monitor display resolution Monitor colours Mouse Minimum Specifications P3, 500 MHz 256 MB 80 MB SVGA 800 x 600 256 Yes

Note: ATI video cards installed with a Catalyst driver set earlier than 4.9 will cause the Portal performance page to stop working if the screen-saver activates. The workaround is to install the latest video drivers from the video card manufacturer.

P/N 260-668060-001 Rev 021, 20 January 2006

Page 6

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Regional Settings Supported


Portal supports the following locales and there are no known limitations: Albanian, Belorussian, Bulgarian, Catalan, Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hebrew, Hungarian, Icelandic, Italian, Japanese, Korean, Latvian, Lithuanian, Macedonian, Norwegian, Polish, Portuguese, Romanian, Russian, Serbian, Serbo-Croatian, Slovak, Slovenian, Spanish, Ukrainien. The following table details known regional settings limitations. Locales Arabic Chinese Known Limitations The calendar does not display the day of the week correctly The date format is not consistent in event browser, the calendar does not display the day of the week correctly, and the alarms page is larger than 800 x 600 resolution The alarms page is larger than 800 x 600 resolution Commas are displayed instead of decimal points when entering the TR/RX spacing and TX/RX frequency. Portal will accept commas when the user enters TX/RX frequency, however it will not accept commas for the TX/RX spacing. The workaround is to use decimal points. Thai Turkish Alarms page is larger than 800 x 600 resolution Some event log entries in the event browser and link history pages may not be displayed

Hindi Swedish

Closed Field Issues


The following table lists field issues that have been fixed by this release. Trouble Ticket # C-00093901 C-00092767 C-00090704 C-00089917 Issue Description A RAC 40 would not reliably lock all demodulators following a power cycle or following a software download. Programming a default route into the static routing did not appear to work correctly. Portal allowed the user to change the TX Power outside of the actual ODU 100 power range. Offline ODU 300 faults were not being displayed in Portal.

P/N 260-668060-001 Rev 021, 20 January 2006

Page 7

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

Closed Significant Issues


The following table lists significant issues that were discovered during development/testing and have been fixed by this release. Software Type Embedded Issue Description Portal was unable to detect hardware changes when a ODU300, ODU300 SP, or ODU 300 HP was interchanged between a single IDU or INU. The workaround was to refresh Portal. Portal notes fields in the event log displayed misleading text. An example was Ring0 SECONDARY path wrapped because of TX path failure, where the Ring0 displayed radio context information and not user defined information.

Portal

Portal and Embedded Compatibility History


Embedded Software Version 2.1.18 and later (Portal auto-version supported) 2.0.44 1.0.29 0.10.31 0.10.20 0.9.32 Matching Portal Software Version 2.1.1, Build 2112 and later 2.0.1, Build 2018 1.0.1, Build 1923 0.10.1, Build 1660 0.10.1, Build 1660 or 1722 0.9.2, Build 1358

Important Notes
1. Traffic may be affected when upgrading software between two specific versions of software. Contact a Stratex Networks Technical Help desk for details, contact details are on page ii of these release notes. 2. Static routes should not be entered when using OSPF. 3. When upgrading from version 2.5.63 or earlier to version 3.0.73 or later, an interim version of software must be loaded first. The interim versions that can be used are 2.6.58, 2.8.5, 2.8.6, 2.9.51, 2.9.66, or 2.9.69. 4. Portal Help integration requires Stratex Help revision 014 or higher. Stratex Help is a standalone help program that is installed separately to Portal, it can be found on the Eclipse Setup installation CD. 5. A license upgrade requires a power cycle if the backplane type changes.

P/N 260-668060-001 Rev 021, 20 January 2006

Page 8

Eclipse Software Release Notes, 3.2.41 Embedded, 3.2.325 Portal

6. A power cycle or a RAC reinsertion is required if a capacity change exceeds the license capacity size. 7. To reduce the traffic outage time during a software load of a IDU 100 1+1 protected radio the following steps should be observed:
a. b. c. d. e. f. Lock all units to TX/RX on the Primary and load only to the high band Secondary IDU/ODU pair Keeping all units TX/RX locked on the Primary, load only to the low band Secondary IDU/ODU pair Switch all units to TX/RX on the Secondary and lock them there. Keeping all units TX/RX locked on the Secondary, load only to the high band Primary IDU/ODU pair. Keeping all units TX/RX locked on the Secondary, load only to the low band Primary IDU/ODU pair Switch all units back to TX/RX auto

Stratex Networks encourages its customers to report problems so we can resolve them as quickly as possible. If you encounter a technical issue please contact us using the information on page ii of these Release Notes

P/N 260-668060-001 Rev 021, 20 January 2006