You are on page 1of 3

Airmaster

DIRECT DRIVE AIR BLASTERS - 115/230V & 230/460V


FEATURES
Cast Aluminum Non-Sparking Propellers
Front & Rear Guards Meet OSHA Standards
Adjustable Tilt Drum on High & Medium Models
Non-Tipping Heavy Base
PERFORMANCE 115/230V & 230/460V
Decibals
@ 10'

HP

CFM

RPM

18"

74
80
80
82
87
86
92
94

1/4
1/4
1/2
1
3
1/2
1-1/2
3

3450
5200
6500
7400
10500
8000
11000
16000

1725
1725
1725
1725
1725
1725
1725
1725

30"

IN
MADE USA

EDP ends in 0

USE
COLUMN
AT RIGHT
FOR LAST
DIGIT OF
Prop EDP NO.

Dia.

18"
24"

30"
36"
42"
48"

2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2160
2141
2162
2163

Prop
Dia.

Decibals
@ 10'

HP

CFM

RPM

88
90
84
86
86
105

1-1/2
2
3
2
5
7-1/2

14850
16800
20000
18000
28000
37000

1725
1725
1150
1150
1150
1150

36"
42"
48"

Actual Propeller 3/4" less.

HIGH STAND MODEL - 360 TILT

EDP
Number

High Stand

PERFORMANCE 115/230V & 230/460V

Prop
Dia.

24"

Welded Steel Construction


Portable or Stationary Mount
115/230V and 230/460V, Totally Enclosed
and Explosion Proof, Ball Bearing Motors

EDP ends in 1

HP

Wt.

TOTALLY ENCLOSED MOTOR


1 Phase
3 Phase
115/230V
230/460V
Cat.
List
Cat.
List
Number
Price
Number
Price

1
3

1
3
1
2
3
2
5
7

228
255
260
270
300
281
340
360
415
420
445
565
590
875

18M-
24M-
24M-
24M-1
24M-3
30M-
30M-1
30M-3
36M-1
36M-2
42M-2
-

$3905
$4068
$4424
$4876
$6325
$4862
$5561
$6629
$6364
$6869
$11,863
-

18MP-
24MP-
24MP-
24MP-1
24MP-3
30MP-
30MP-1
30MP-3
36MP-1
36MP-2
36MP-3
42MP-2
42MP-5
48MP-7

$3858
$4011
$4398
$4709
$5234
$4847
$5272
$5612
$6099
$6152
$7282
$7559
$8631
$14,216

EDP ends in 2

EDP ends in 3

EXPLOSION PROOF MOTOR


1 Phase
3 Phase
115/230V
230/460V
Cat.
List
Cat.
List
Number
Price
Number
Price

18M-X
24M-X
24M-X
24M-1X
30M-X
30M-1X
36M-1X
36M-2X
-

$4557
$4671
$5226
$5711
$5682
$8154
$9056
$9937
-

18MP-X
24MP-X
24MP-X
24MP-1X
24MP-3X
30MP-X
30MP-1X
30MP-3X
36MP-1X

42MP-5X
48MP-7X

$4664
$4769
$5359
$5714
$6384
$5823
$6266
$6818
$7094
$7330
$9015
$8611
$10,591
$15,843

18M-MX
24M-MX
24M-MX
24M-1MX
30M-MX
30M-1MX
36M-1MX
36M-2MX
-

$4059
$4142
$4670
$5187
$5088
$6802
$8493
$9350
-

18MP-MX
24MP-MX
24MP-MX
24MP-1MX
24MP-3MX
30MP-MX
30MP-1MX
30MP-3MX
36MP-1MX
36MP-2MX
36MP-3MX
42MP-2MX
42MP-5MX
48MP-7MX

$4161
$4394
$4847
$5173
$5862
$5231
$5666
$6203
$6680
$6749
$8434
$7901
$9974
$14,814

18M-LX
24M-LX
24M-LX
24M-1LX
30M-LX
30M-1LX
36M-1LX
36M-2LX
-

$3500
$3566
$4095
$4612
$4473
$6936
$7710
$8551
-

18MP-LX $3587
24MP-LX $3675
24MP-LX $4267
24MP-1LX $4592
24MP-3LX $5272
30MP-LX $4601
30MP-1LX $5173
30MP-3LX $5567
36MP-1LX $5728
$5951
36MP-2LX
$7636
36MP-3LX
$7074
42MP-2LX
42MP-5LX $9065
48MP-7LX $13,843

36MP-2X
36MP-3X
42MP-2X

MEDIUM STAND MODEL - 360 TILT


18"
24"

Medium Stand

30"
36"
42"
48"

2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2200
2181
2202
2203
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2240
2221
2242
2243

1
3
1
2
3
2
5
7

160
165
180
190
260
220
260
277
320
325
350
415
440
745

18M-M
24M-M
24M-M
24M-1M
24M-3M
30M-M
30M-1M
30M-3M
36M-1M
36M-2M
42M-2M
-

$3399
$3689
$3902
$4345
$5951
$4267
$4977
$6030
$5803
$6285
$11,173
-

1
3

1
3
1
2
3
2
5
7

87
115
120
130
160
141
200
220
250
255
280
315
340
685

18M-L
24M-L
24M-L
24M-1L
24M-3L
30M-L
30M-1L
30M-3L
36M-1L
36M-2L
42M-2L
-

$2837
$2956
$3334
$3774
$6749
$3655
$4351
$5403
$5018
$5488
$10,365
-

1
3

18MP-M
24MP-M
24MP-M
24MP-1M
24MP-3M
30MP-M
30MP-1M
30MP-3M
36MP-1M
36MP-2M
36MP-3M
42MP-2M
42MP-5M
48MP-7M

$3350
$3492
$3882
$4167
$4690
$4253
$4660
$5010
$5509
$5567
$6696
$6847
$7925
$11,646

LOW STAND MODEL


18"
24"

30"
36"
Low Stand

42"
48"

18MP-L
24MP-L
24MP-L
24MP-1L
24MP-3L
30MP-L

30MP-1L
30MP-3L
36MP-1L
36MP-2L
36MP-3L
42MP-2L
42MP-5L
48MP-7L

$2788
$2916
$3311
$3576
$4098
$3626
$4022
$4374
$4716
$4769
$5902
$6020
$7094
$10,681

NOTES: Fans are pre-assembled, tested and ready to install. 3PECIFYVOLTAGEREQUIREDWHENORDERING

Submittal sheets available at www.airmasterfan.com

- 29 -

Airmaster

DIRECT DRIVE AIR BLASTERS - 115/230V & 230/460V


ACCESSORIES & MODIFICATIONS

Prop
Dia.

EDP
Number

18"
24"
30"
36"

22440
22450
22460
22470

Description

Wt.

List

YOKE MOUNT - TILT ONLY


For wall or ceiling mounting.

45
50
55
70

Add the following


to low stand prices:

$778
$870
$890
$1084

45
50
55
70

Add the following


to low stand prices:

$1901
$1980
$2217
$2468

YOKE MOUNT - TILT & SWIVEL


18"
24"
30"
36"

22441
22451
22461
22471

For wall or ceiling mounting.

CASTERS (For Low & Medium Models)


18"-30"
36"-48"

Two fixed / two swivel (with locking device)

22480
22490

12
16

Tilt Mount

OPTIONAL PREWIRED STARTER SWITCHES


EDP
Number

Motor
HP

1 Phase
Standard

3 Phase
Standard

91901
91902
91903

1/4, 1/2, 1
1 1/2
1/4, 1/2, 1,
1 1/2, 2,3
5

$669
$1571
-

$1579

$1797

91904

$611
$857

Add the following to low


or medium stand prices:

D
SQUARE

(4) HOLES
9/16 TYP
MOUNTING BASE
1
TYP

1 TYP

SPIRAL GUARDS
FRONT & REAR

3 X 3 X 3/16
SQUARE TUBING

E
3 CHANNEL

C
A
B
CAST ALUMINUM
PROPELLER

T IL
TC

ON ST RUCT IO

AIR BLASTER YOKE MOUNT DIMENSIONS


SIZE
A
B
C*
C**
D
E
F
18
18
20
17
15
15
20
17
24
24
26
21
15
15
20
21
30
30
32
25
15
15
20
25
29
36
36
38
29
18
18
24
* Dimension for Tilt Only; ** Dimension for Tilt and Swivel Only

D
42
42
42
42
42
42

E
20
26
32
38
44
51

PROP DIA
18
24
30
36
42
48

G
23
29
35
41
47
53

H
28
28
28
28
28
36

J
21
27
33
39
45
52

K
18
24
30
36
42
48

W
20
20
20
24
24
28

F
32
32
32
32
32
32

D
SQUARE

(4) HOLES
9/16 TYP

SWIVEL MOUNTING BASE

1
TYP

1 TYP

SPIRAL GUARDS
FRONT & REAR

3 X 3 X 3/16
SQUARE TUBING

TI L

3 CHANNEL

C
A
B
CAST ALUMINUM
PROPELLER

TIL

T&

Tilt & Swivel Mount


W

TUBE
HANDLE

IO
N

C
25
25
25
25
25
25

T
UC
WI V
EL CONS TR

B
30
30
30
30
30
30

&S

A
23
29
35
41
47
53

PROP DIA
18
24
30
36
42
48

IO
N

AIR BLASTER DIMENSIONS

CT
SW
I VEL CONST RU

GUARD (2) SIDES


HANDLES

SWITCH
PLATE

GUARD (2) SIDES

HANDLES

GUARD (2 ) SIDE S
HANDL E S

3 CHANNEL
IRON STAND

1 x 1 x .125
ANGLE IRON STAND

HIGH STAND

MEDIUM STAND

- 30 -

LOW STAND

517.764.2300

Airmaster

TERMINOLOGY & PRINCIPLES


BASIC TERMINOLOGY

VENTILATION - Moving air from one area to another.


CIRCULATION - The moving of air within a given area.
CFM - The volume of air moved by a fan expressed in cubic feet per minute.
SP / STATIC PRESSURE - The resistance to flow in any air moving system, expressed in inches of water column (IN. W.G.). Fans are
rated in CFM at various static pressures.
HP / HORSEPOWER - The most common measurement of mechanical power of a motor.
BHP - The horsepower required to drive the fan at a given RPM and Performance Point.
VELOCITY - The speed, expressed in FPM (feet per minute), of air moving through a given area such as a duct, face area of a hood,
air intake opening or cross section of a room or booth, or from an air circulator.
AIR CHANGES - The time required for a complete air change in given space. Normally expressed in minutes per change.

VENTILATION PRINCIPLES
AIR CHANGE METHOD - Probably the most common form of ventilation. Normally used for general ventilation of a building or an area
in a building. Determine the volume of the area by multiplying the LENGTH X WIDTH X HEIGHT of the area, then divide the volume by the
frequency of air change to determine the required CFM airflow. Determine the frequency of air change from the table below.
Several factors will affect your selection of air change frequency, a warmer climate will require a more frequent change than a more
temperate one. Larger rooms often require less frequent air changes.
CAUTION - When ventilating an area that contains hazardous (explosive) fumes or dust in the air, specify a fan with an explosion proof
motor and spark resistant construction.
INTAKE AIR - You cannot exhaust air without an intake air source, the air you exhaust from a building has to be replaced, a source of
intake air located on the end of the building opposite the fan provides the best ventilation. Intake air velocity should be kept below
500-FPM velocity. Divide the CFM rating of the fan by the required velocity to determine the minimum square feet of face area for proper
intake air (CFM / Velocity = Area). Bird screen in an air intake has a negligible effect on the open area, but insect screen reduces the
open area by 50%. Louvers will also reduce the actual open area, see the louver data for actual open area.
AVERAGE AIR CHANGES REQUIRED
MINUTES/CHANGE
FOR GOOD VENTILATION
ASSEMBLY HALLS
AUDITORIUMS
BAKERIES
BANKS
BARNS
BARS
BOILER ROOMS
BOWLING ALLEYS
CHURCHES
CLUBS
DAIRIES
DANCE HALLS
DINING ROOMS
DRY CLEANERS
ENGINE ROOMS
FACTORIES
FORGE SHOPS
FOUNDRIES
GARAGES
GENERATOR ROOMS
GYMNASIUMS
KITCHENS-HOSPITALS
KITCHENS-RESTAURANTS
LABORATORIES
LAVATORIES
LAUNDRIES
MARKETS
OFFICES
PACKING HOUSES
PLATING ROOMS
POOL ROOMS
PROJECTION ROOMS
RECREATION ROOMS
RESIDENCES
SALES ROOMS
THEATERS
TRANSFORMER ROOMS
WAREHOUSES

Submittal sheets available at www.airmasterfan.com

- 31 -

2-10
2-10
2-3
3-10
10-20
2-5
1-5
2-10
5-10
2-10
2-5
2-10
3-10
1-5
1-3
2-5
2-5
1-5
2-10
2-5
2-10
2-5
1-3
1-5
2-5
1-3
2-10
2-10
2-5
1-5
2-5
1-3
2-10
2-5
2-10
2-8
1-5
2-10

You might also like