VALVULA DE ESTRANGULAMIENTO

Ing. M. EDUARDO SOTO S.

VLVULA DE ESTRANGULAMIENTO

p
p1

p1 - p2

p2

Qe
Qe=Qs

Qs

VLVULAS DE CONTROL DE CAUDAL

CADA DE PRESIN EN UN ESTRANGULAMIENTO

125

p
p k Q 2

40

8 1
5

Q
8

F = 1 ton

p
150 135 130

bar

A = 100 cm 2 p 2 = F / A = 10 bar

10

Q ( l/min ) 2 l/min

8 l/min

p = p1 - p 2 p = 135 - 10 = 125 bar

150 bar

p 1 = 135 bar

Q = 10 l/min

F = 10 ton

p 150 140 130

bar A = 100 cm
2

p 2 = F / A = 100 bar

5 150 bar

10

Q ( l/min )

p = p1 - p2 5 l/min p = 140 - 100 = 40 bar

5 l/min p 1 = 140 bar

Q = 10 l/min

F = 14 ton

p
150 148 130

bar

A = 100 cm p
2

= F / A = 140 bar

10

Q ( l/min )

1 l/min

p=p1- p

150 bar

p = 148 - 140 = 8 bar 9 l/min p


1

= 148 bar

Q = 10 l/min

EL PISTN SALE LENTO

REGULACION PRIMARIA

REGULACION SECUNDARIA

EL PISTN ENTRA LENTO

REGULACION PRIMARIA

REGULACION SECUNDARIA

VALVULA DE ESTRANGULAMIENTO CON CHECK