You are on page 1of 22

Shipwiring and Marine Cables

Shipwiring and Marine Cables


We offer shipwiring and marine cables with approvals of the Germanischer Lloyd, Lloyds Register of Shipping, American Bureau of Shipping, Det Norske Veritas, Bureau Veritas, USSR Register of Shipping, Verband Deutscher Elektrotechniker. Great parts of the programm are available within short time from our stock. Cutting lengths are available for additional charge. On request we send with each order a corresponding production or company certificate.

Contents
Description P Ship and Marine Cables
MYY-J, MYY-O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MGH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MGCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MGSG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MGSGO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LMKK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LFMKK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XLFMKK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LMGSG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LMGSGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMGCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMGSGO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMSGSGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LFMGSSGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LFMSGSSGO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MPRXCX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P 1 P 2 P 3 P 4 P 5 P 6 P 7 P 8 P 9 P 10 P 11 P 12 P 13 P 14 P 15 P 16 P 17 P 18 P 19

Type

Page

Ships power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ships power cables 0,6/1 kV, halogen-free . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ships power cables 0,6/1 kV, halogen-free . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marine power cables halogen-free, copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marine power cables halogen-free, copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Light marine power cables copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marine telephone cables 250 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Light marine telephone cables copper screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marine power cables halogen-free, copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marine power cables halogen-free, copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Telephone ship cables 250 V, halogen-free. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Telephone marine cables halogen-free, copper screen . . . . . . . . . . . . . . . . . . . . . . Telephone marine cables with good crosstalk attenuation . . . . . . . . . . . . . . . . Light marine telephone cables halogen-free, 2 x copper screen. . . . . . . . . Light marine telephone cables halogen-free, 2 x copper screen. . . . . . . . . Single core ship control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multi core ship control cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ships power cables 0,6/1 kV, halogen-free . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ships power cables 0,6/1 kV, halogen-free . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ships Power cables MYY-J and MYY-O

Technical data
According to IEC 92-3 Nominal voltage 250 V Approved by Germanischer Lloyd, Lloyds Register of Shipping, Bureau Veritas and other approvals available (Det Norske Veritas etc.)

Cable structure
Plain copper conductors, stranded type PVC core insulation 2 to 5 cores laid up Elastic filling compound PVC outer sheath, colour light grey O-Types black/blue black/blue/ brown black/blue/ brown/black black/blue/ brown/black/ black

Application
Ships power cables for all uses recommended in IEC 92-3.

Colour code J-Types 2 cores: 3 cores: green-yellow/ black/blue 4 cores: green-yellow/ black/blue/brown 5 cores: green-yellow/ black/blue/ brown/black

Part No. MYY-J 59201 59202 59203 59204 59205

No. cores x cross-sec. mm2 3G 1,5 4G 1,5 5G 1,5 3G 2,5 4G 2,5

Outer 1 ca. mm

Cop. weight kg / km 43 58 72 72 96

Weight ca. kg / km

AWGno.*)

Part No. MYY-O 59206 59207 59208 59209 59210 59211

No. cores x cross-sec. mm2 2 x 1,5 3 x 1,5 4 x 1,5 5 x 1,5 3 x 2,5 4 x 2,5

Outer 1 ca. mm

Cop. weight kg / km 29 43 58 72 72 96

Weight ca. kg / km

AWGno.*)

9,5 10,0 11,0 11,0 12,0

140 176 210 224 227

16 16 16 14 14

9,0 9,5 10,0 11,0 11,0 12,0

128 140 176 210 224 227

16 16 16 16 14 14

G = with green-yellow earth core X = without green-yellow earth core (OZ) *) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P1

Ships Power Cables MGH 0,6/1 kV (MGG*)


halogen-free, according to DIN 89160/98

Technical data
As per DIN 89160 edition 1998 and IEC 600292-353 Temperature range max. +858 C conductor temperature Min. installation temperature 108 C Nominal voltage U0/U 0,6/1 kV Bending radius approx. 4 x cable 1 Approved by Germanischer Lloyd, Lloyds Register of Shipping, American Bureau of Shipping, Det Norske Veritas, Bureau Veritas, Verband Deutscher Elektrotechniker. Russian Maritime Register of Shipping and Registro Italiano Navale are in preparation Flame retardant according to SOLAS definition (according to IEC 60332-3 category A)

Cable structure
Stranded, bare copper conductors to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 HEPR core insulation (Hard grade EPR) Cores stranded in layers with optimal lay-length Overall filled inner sheath, covered by filling compound Outer sheath, Polyolefin basiscompound, flame retardant, sheath colour black up to 5 cores grey 7 and more cores Colour code1) 1 core: natural colour 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/black 5 cores: black/blue/brown/black/ black 6 cores and more: all cores natural coloured, printed with numbers, starting in center with number 1

Application
For stationary installation beneath the first metal deck level.

Part No. 59060 59061 59062 59063 59064 59065 59066 59067 59068 59069 59070 59071 59072 59073 59074 59075 59076 59077 59078 59079 59080 59081 59082 59083 59084 59085 59086

No. cores x cross-sec. mm2 1 x 1,5 1 x 2,5 1x4 1x6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 2 x 25 3 x 1,5 3 x 2,5 3x4 3x6

Outer 1 ca. mm 4,5 5,0 6,0 7,5 8,5 9,5 11,0 12,0 13,5 15,5 17,5 19,5 21,5 23,5 26,5 29,5 10,0 11,0 12,0 13,0 15,5 17,5 21,0 10,5 11,5 12,5 14,0

Cop. weight kg / km 14 24 38 58 96 154 240 336 480 672 912 1152 1440 1776 2304 2880 29 48 77 115 192 307 480 43 72 115 173

Weight ca. kg / km 60 70 80 110 150 220 320 420 560 780 1030 1290 1590 1960 2560 3200 130 170 220 280 410 590 880 160 210 270 350

AWGno.*) 16 14 12 10 8 6 4 2 1 2/0 3/0 4/0 kcmil kcmil kcmil kcmil 16 14 12 10 8 6 4 16 14 12 10

Part No. 59087 59088 59089 59090 59091 59092 59093 59094 59095 59096 59097 59098 59099 59100 59101 59102 59103 59104 59105 59106 59107 59108 59109 59110 59111 59112 59113

No. cores x cross-sec. mm2 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 4 x 1,5 4 x 2,5 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 5 x 1,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5 19 x 1,5 24 x 1,5

Outer 1 ca. mm 16,5 18,5 22,0 24,5 28,0 33,0 37,0 41,0 11,0 12,0 13,5 15,5 18,0 21,0 24,5 27,0 31,0 36,5 41,0 12,0 13,0 15,5 16,0 17,0 18,0 19,5 22,0

Cop. weight kg / km 288 461 720 1008 1440 2016 2736 3456 58 96 154 230 384 614 960 1344 1920 2688 3648 72 101 144 173 202 230 274 346

Weight ca. kg / km 510 750 1130 1500 1970 2770 3680 4580 200 250 330 440 660 950 1460 1920 2520 3530 4730 230 290 360 410 470 535 610 760

AWGno.*) 8 6 4 2 1 2/0 3/0 4/0 16 14 12 10 8 6 4 2 1 2/0 3/0 16 16 16 16 16 16 16 16

300 350 500 600

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

) Halogeneted type MGG will be substituted according to DIN, edition 1998 through the halogen-free type MGH.

P2

Ships Power Cables MGCH 0,6/1 kV (MGCG*)


halogen-free, according to DIN 89158/98

Technical data
As per DIN 89160 edition 1998 and IEC 600292-353 Temperature range max. +858 C conductor temperature Min. installation temperature 108 C Nominal voltage U0/U 0,6/1 kV Bending radius approx. 6 x cable 1 Approved by Germanischer Lloyd, Lloyds Register of Shipping, American Bureau of Shipping, Det Norske Veritas, Bureau Veritas, Verband Deutscher Elektrotechniker. Russian Maritime Register of Shipping and Registro Italiano Navale are in preparation Flame retardant according to SOLAS definition (according to IEC 60332-3 category A)

Cable structure
Stranded, bare copper conductors to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 HEPR core insulation (Hard grade EPR) Cores stranded in layers with optimal lay-length Overall filled inner sheath, covered by filling compound Separator-foil Bare copper braided screen Separator-foil Outer sheath, Polyolefin basiscompound sheath colour black up to 5 cores grey 7 and more cores Colour code1) 1 core: natural colour 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/black 5 cores: black/blue/brown/black/ black 6 cores and more: all cores natural coloured, printed with numbers, starting in center with number 1

Application
For stationary installation beneath the first metal deck level.

Part No. 59000 59001 59002 59003 59004 59005 59006 59007 59008 59009 59010 59011 59012 59013 59014 59015 59016 59017 59018 59019 59020 59021 59022 59023 59024 59025 59026

No. cores x cross-sec. mm2 1 x 1,5 1 x 2,5 1x4 1x6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 2 x 25 3 x 1,5 3 x 2,5 3x4 3x6

Outer 1 ca. mm 6,5 7,0 7,5 8,5 9,5 10,0 12,0 13,0 15,0 17,0 19,0 21,0 23,0 25,5 28,5 31,0 11,0 12,0 13,0 14,5 17,0 19,5 22,5 12,0 12,5 13,5 15,5

Cop. weight kg / km 48 60 81 104 149 214 311 416 572 779 1034 1316 1615 1968 2506 3186 105 132 170 217 307 471 670 125 161 215 282

Weight ca. kg / km 85 90 110 140 190 270 380 480 660 900 1170 1410 1750 2160 2770 3440 180 220 280 380 500 710 1020 210 260 330 450

AWGno.*) 16 14 12 10 8 6 4 2 1 2/0 3/0 4/0 kcmil kcmil kcmil kcmil 16 14 12 10 8 6 4 16 14 12 10

Part No. 59027 59030 59031 59032 59033 59034 59035 59036 59037 59038 59039 59040 59041 59042 59043 59044 59045 59046 59047 59048 59049 59050 59051 59052 59053 59054 59055

No. cores x cross-sec. mm2 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 4 x 1,5 4 x 2,5 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 5 x 1,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5 19 x 1,5 24 x 1,5

Outer 1 ca. mm 17,5 19,5 23,5 26,0 29,0 34,5 39,0 43,0 12,5 13,5 15,0 16,5 19,0 21,0 26,0 28,5 32,5 38,5 44,0 13,5 14,0 16,5 18,0 18,5 19,5 20,5 23,5

Cop. weight kg / km 417 636 924 1233 1703 2413 3192 3975 147 190 284 371 545 796 1170 1578 2278 3090 4110 171 209 318 353 392 432 486 601

Weight ca. kg / km 620 870 1280 1680 2180 3020 4050 5000 240 300 430 540 780 1090 1630 2120 2750 3900 5160 290 380 450 500 560 630 710 880

AWGno.*) 8 6 4 2 1 2/0 3/0 4/0 16 14 12 10 8 6 4 2 1 2/0 3/0 16 16 16 16 16 16 16 16

300 350 500 600

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

) Halogeneted type MGG will be substituted according to DIN, edition 1998 through the halogen-free type MGCH.

P3

Ships Power Cables MGSG

halogen-free, copper screened

Technical data
According to VG 95 218 part 50, screened. Insulation remains operational for 20 min. under directly exposed to open flame according to DIN VDE 0472, part 814 and IEC 60331 Conductor operating temperature approx. +858 C Min. installation temperature 108 C Nominal voltage U0/U 0,6/1 kV Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductor to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 Heat-resistant EPR-insulation 3GI3, to DIN VDE 0207 part 20 Cores stranded in layers with optimal lay-length Filling compound covering all cores Flame-proof foil Plain copper braided overall screening Polyester tape Outer sheath of halogen-free, flameretardant elastomer compound based on olefin coplymers jacket colour black Colour code 1 core: black 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/black

Application
Halogen-free power cables for marine craft are used for permanent installation on ships in all rooms and open decks as control and power cables.

Part No. 59220 59221 59222 59223 59224 59225 59226 59227 59228 59229 59230 59231 59232 59233 59234 59235 59236 59237 59238 59239 59240

No. cores x cross-sec. mm2 1x4 1x6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 2 x 25

Outer 1 ca. mm 9,0 9,6 10,7 11,8 13,8 15,1 17,0 18,9 21,5 23,3 25,5 27,9 31,2 34,4 15,5 16,5 17,5 19,0 20,5 23,0 27,0

Cop. weight kg / km 81 104 149 214 311 416 572 779 1034 1316 1615 1968 2506 3345 105 132 170 217 307 471 670

Weight ca. kg / km 170 200 260 340 490 610 770 1000 1350 1600 1900 2350 3000 3650 370 420 490 600 750 980 1350

AWGno.*) 12 10 8 6 4 2 1 2/0 3/0 4/0 kcmil kcmil kcmil kcmil 16 14 12 10 8 6 4

Part No. 59241 59242 59243 59244 59245 59246 59247 59248 59249 59250 59251 59252 59253 59254 59255 59256 59257 59258 59259 59260 59261

No. cores x cross-sec. mm2 3 x 1,5 3 x 2,5 3x4 3x6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95

Outer 1 ca. mm 16,5 17,0 18,5 19,5 22,0 24,5 28,5 31,5 35,5 40,0 46,0 50,0 19,5 21,0 23,5 26,5 31,0 34,5 39,0 44,5 51,0

Cop. weight kg / km 125 161 215 282 417 636 924 1233 1703 2413 3192 3975 284 371 545 796 1170 1578 2278 3090 4110

Weight ca. kg / km 400 470 550 680 880 1160 1660 2070 2660 3510 4780 5770 650 780 1050 1450 2050 2600 3360 4530 6030

AWGno.*) 16 14 12 10 8 6 4 2 1 2/0 3/0 4/0 12 10 8 6 4 2 1 2/0 3/0

300 350 500 600

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P4

Ships Power Cables MGSGO

halogen-free, copper screened

Technical data
According to VG 95 218 part 60, screened. The core insulation continues to function during a fire without the need for extra flame-proof taping Conductor operating temperature max. +858 C Nominal voltage U0/U 0,6/1 kV Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductors Heat-resistant EPR-insulation 3GI3, to DIN VDE 0207 part 20 Cores stranded in layers with optimal lay-length Filling compound covering all cores Foil screen Plain copper braided screen Polyester tape Chloroprene based outer sheath 5GM3, to DIN VDE 0207 part 21, flame retardant and oil resistant jacket colour black Colour code 1 core: black 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/black

Application
Halogen-free power cables for marine craft are used for permanent installation on ships in all rooms and open decks as control and power cables.

Part No. 59270 59271 59272 59273 59274 59275 59276 59277 59278 59279 59280 59281 59282 59283 59284 59285 59286 59287 59288 59289 59290

No. cores x cross-sec. mm2 1x4 1x6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 2 x 25

Outer 1 ca. mm 9,0 10,0 11,0 12,0 14,0 15,5 17,5 19,5 22,0 23,5 26,0 28,5 31,5 34,4 15,0 16,0 17,0 18,5 20,0 22,5 26,5

Cop. weight kg / km 81 104 149 214 311 416 572 779 1034 1316 1615 1968 2506 3345 105 132 170 217 307 471 670

Weight ca. kg / km 170 200 260 340 480 590 760 980 1300 1550 1850 2300 2950 3600 340 400 460 570 720 940 1300

AWGno.*) 12 10 8 6 4 2 1 2/0 3/0 4/0 kcmil kcmil kcmil kcmil 16 14 12 10 8 6 4

Part No. 59291 59292 59293 59294 59295 59296 59297 59298 59299 59300 59301 59302 59303 59304 59305 59306 59307 59308 59309 59310 59311

No. cores x cross-sec. mm2 3 x 1,5 3 x 2,5 3x4 3x6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95

Outer 1 ca. mm 15,5 16,5 18,0 19,0 21,5 24,0 28,0 31,0 35,0 39,0 45,5 49,5 19,0 20,5 23,0 26,0 30,5 34,0 38,5 44,0 50,5

Cop. weight kg / km 125 161 215 282 417 636 924 1233 1703 2413 3192 3975 284 371 545 796 1170 1578 2278 3090 4110

Weight ca. kg / km 380 440 520 640 840 1110 1610 2020 2610 3450 4710 5680 620 750 1010 1400 2000 2530 3280 4450 5930

AWGno.*) 16 14 12 10 8 6 4 2 1 2/0 3/0 4/0 12 10 8 6 4 2 1 2/0 3/0

300 350 500 600

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P5

Light Marine Power Cables LMKK

copper screened

Technical data
According to VG 88 775/66 Conductor operating temperature max. +858 C Min. installation temperature 108 C Nominal voltage 500 V Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductor to DIN VDE 0295 cl. 2 and IEC 60228 cl. 2, BS 6360 cl. 2, water tight PVC insulation with PA protective coating Core stranded in layers with optimal lay-length PVC inner sheath Waterproofed plain copper braided screen PVC outer sheath, colour green Colour code 2 cores: grey/black 3 cores: grey/black/red 4 cores: grey/black/red/blue 5 cores: grey/black/red/blue/black 7 33 cores: all cores black with white numbering, core 1 placed centrally.

Application
For fixed installation on marine craft above and below deck.

Part No. 59320 59321 59322 59323 59324 59325 59326 59327 59328

No. cores x cross-sec. mm2 2 x 1,5 3 x 1,5 4 x 1,5 5 x 1,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5

Outer 1 ca. mm 10,0 10,4 11,3 12,1 13,2 15,7 16,5 17,1 17,9

Cop. weight kg / km 89 105 131 146 180 244 276 310 342

Weight ca. kg / km 160 180 210 240 300 400 440 490 550

AWGno.*) 16 16 16 16 16 16 16 16 16

Part No. 59329 59330 59331 59332 59333 59334 59335

No. cores x cross-sec. mm2 19 x 1,5 24 x 1,5 27 x 1,5 33 x 1,5 2 x 2,5 3 x 2,5 4 x 2,5

Outer 1 ca. mm 18,6 21,1 21,5 22,9 11,2 11,7 12,4

Cop. weight kg / km 401 494 539 633 114 144 171

Weight ca. kg / km 620 760 820 970 210 240 280

AWGno.*) 16 16 16 16 14 14 14

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P6

Light Marine Telephone Cables LFMKK 250 V

Technical data
According to VG 88 777 Conductor operating temperature max. +858 C Min. installation temperature 108 C Nominal voltage 250 V Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductor to DIN VDE 0295 cl. 2 and IEC 60228 cl. 2 PVC insulation sleeve to DIN VDE 0207 part 4 PA protective covering to VDE 0253 Four cores formed into a star-quad, two diagonally opposite cores make up a telecommunications pair, star-quads laid up concentrically PVC inner jacket Plain copper wire braided screen Outer jacket made of green, heat resistant PVC Colour code 2 pairs: grey/black-blue/yellow 4 pairs: 1. pair red/black 2. pair green/yellow 3. pair blue/yellow 4. pair blue/yellow 6 10 pairs: 1 twist/group red/black-blue/yellow 2 twist/group green/black-blue/yellow 3 and following groups grey/black-blue/yellow 14 and 16 pairs: 1st layer group grey/black-blue/yellow 2nd layer 1. group red/black-blue/yellow 2. group green/black-blue/yellow 3. group and above grey/black-blue/yellow

Application
This cable type can be installed above or below deck and is designed for radio and radar units.

Part No. 59120 59121 59122

No. cores x cross-sec. mm2 2 x 2 x 0,75 4 x 2 x 0,75 6 x 2 x 0,75

Outer 1 ca. mm 9,0 13,0 15,0

Cop. weight kg / km 89 142 189

Weight ca. kg / km 155 270 360

AWGno.*) 18 18 18

Part No. 59123 59124 59125

No. cores x cross-sec. mm2 8 x 2 x 0,75 10 x 2 x 0,75 14 x 2 x 0,75

Outer 1 ca. mm 16,5 18,0 19,0

Cop. weight kg / km 225 272 338

Weight ca. kg / km 415 505 570

AWGno.*) 18 18 18

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P7

Light Marine Telephone Cables XLFMKK copper screened

Technical data
According to VG 88 778/66 Conductor operating temperature max. +858 C Min. installation temperature 108 C Nominal voltage 250 V Minimum bending radius approx. 5 x cable 1 Approved by german ministry of defense

Cable structure
Stranded copper conductors to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and ICE 60228 cl. 2 PVC core insulation with polyamid coating Cores laid up in pairs Pairs copper screened Separating foil PVC inner sheath Plain copper braided screen, waterproofed PVC outer sheath, colour green Colour code All sizes are colour coded.

Application
For fixed installation on marine craft above and below deck.

Part No. 59336 59337 59338

No. cores x cross-sec. mm2 2 x 2 x 0,75 4 x 2 x 0,75 11 x 2 x 0,75

Outer 1 ca. mm 16,0 18,1 26,2

Cop. weight kg / km 160 277 658

Weight ca. kg / km 370 490 1080

AWGno.*) 18 18 18

Works photo: Jos. L. Meyer GmbH &; Co.

P8

Marine Power Cables LMGSG

halogen-free, copper screened

Technical data
According to VG 95 281 part 51 screened. No loss of insulation if under exposure to flame Conductor operating temperature max. +858 C Min. installation temperature 108 C Nominal voltage 500 V Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductor to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 Heat resistant EPR-insulation 3GI3, to DIN VDE 0207 part 20 with flame resistant taping Core stranded in layers with optimal lay-length Filling compound covering all cores Flame resistant foil taping Plain copper braided screening Polyester foil taping Chloroprene based outer sheath, flame retardant and halogen-free sheath colour black Colour code 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/black 5 cores: black/blue/brown/black/black 7 33 cores: all cores black, number coded, core 1 placed centrally.

Application
For fixed installation on marine craft above and below deck.

Part No. 59340 59341 59342 59343 59344 59345 59346 59347 59348

No. cores x cross-sec. mm2 2 x 1,5 3 x 1,5 4 x 1,5 5 x 1,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5

Outer 1 ca. mm 10,0 10,5 11,5 13,0 14,0 17,0 17,5 18,0 19,0

Cop. weight kg / km 89 105 131 146 180 244 276 310 342

Weight ca. kg / km 135 160 190 220 280 360 400 450 500

AWGno.*) 16 16 16 16 16 16 16 16 16

Part No. 59349 59350 59351 59352 59353 59354 59355 59356

No. cores x cross-sec. mm2 19 x 1,5 24 x 1,5 27 x 1,5 33 x 1,5 2 x 2,5 3 x 2,5 4 x 2,5 7 x 2,5

Outer 1 ca. mm 20,0 23,0 23,5 25,5 11,5 12,0 13,0 15,4

Cop. weight kg / km 401 494 539 633 114 144 171 266

Weight ca. kg / km 550 700 750 880 190 220 260 380

AWGno.*) 16 16 16 16 14 14 14 14

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P9

Marine Power Cables LMGSGO

halogen-free, screened

Technical data
According to VG 95 281 part 61 screened. No loss of insulation if directly exposed to fire. No special fire-proofed layer necessary Conductor operating temperature max. +858 C Nominal voltage 500 V Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductor Heat resistant EPR-insulation 3GI3, to DIN VDE 0207 part 20 Core stranded in layers with optimal lay-length Halogen-free inner filling sheath Copper braided screening Polyester foil taping Chloroprene based outer sheath, flame retardant and halogen-free sheath colour black Colour code 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/black 5 cores: black/blue/brown/black/black 7 33 cores: all cores black, number coded, core 1 placed centrally.

Application
For fixed installation on marine craft above and below deck.

Part No. 59360 59361 59362 59363 59364 59365 59366 59367 59368 59369

No. cores x cross-sec. mm2 2 x 1,5 3 x 1,5 4 x 1,5 5 x 1,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5 19 x 1,5

Outer 1 ca. mm 9,0 9,5 10,5 10,5 11,5 14,0 14,5 15,0 16,0 16,5

Cop. weight kg / km 89 105 131 146 180 244 276 310 342 401

Weight ca. kg / km 110 140 170 180 230 310 350 400 450 510

AWGno.*) 16 16 16 16 16 16 16 16 16 16

Part No. 59370 59371 59372 59373 59374 59375 59376 59377

No. cores x cross-sec. mm2 24 x 1,5 27 x 1,5 33 x 1,5 2 x 2,5 3 x 2,5 4 x 2,5 6 x 2,5 7 x 2,5

Outer 1 ca. mm 19,0 19,5 21,0 10,0 10,5 11,5 13,0 13,0

Cop. weight kg / km 494 539 633 114 144 171 242 266

Weight ca. kg / km 620 680 810 160 190 230 300 320

AWGno.*) 16 16 16 14 14 14 14 14

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P 10

Ships Telephone Cables FMGCH 250 V (FMGCG*)


halogen-free, according to DIN 89159/98

Technical data
As per DIN 89160 edition 1998 and IEC 60092-375 Temperature range max. +858 C conductor temperature Nominal voltage 250 V Insulation resistance 14000 MOhm x km Bending radius approx. 5 x cable 1 Approved by Germanischer Lloyd, Lloyds Register of Shipping, American Bureau of Shipping, Det Norske Veritas, Bureau Veritas, Verband Deutscher Elektrotechniker. Russian Maritime Register of Shipping and Registro Italiano Navale are in preparation Flame retardant according to SOLAS definition (according to IEC 60332-3 category A)

Cable structure
Stranded, bare copper conductors to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 HEPR core insulation (Hard grade EPR) All cores natural coloured, printed with numbers, starting in center with number 1 Cores stranded in pairs with optimal lay-length Pairs stranded in layers with optimal lay-length Separator-foil Bare copper braided screen Separator-foil Outher sheath, Polyolefin basiscompound sheath colour, green

Application
This cable type is used as a measuring, control and communication cable in radio, radar and information systems. For use above and below decks.

Part No. 59138 59139 59140 59141

No. cores x cross-sec. mm2 1 x 2 x 0,75 2 x 2 x 0,75 4 x 2 x 0,75 7 x 2 x 0,75

Outer 1 ca. mm 8,5 9,0 13,0 15,5

Cop. weight kg / km 62 87 153 230

Weight ca. kg / km 90 130 230 340

AWGno.*) 18 18 18 18

Part No. 59142 59143 59144 59145

No. cores x cross-sec. mm2 10 x 2 x 0,75 14 x 2 x 0,75 19 x 2 x 0,75 24 x 2 x 0,75

Outer 1 ca. mm 18,5 21,0 24,0 27,0

Cop. weight kg / km 319 445 525 663

Weight ca. kg / km 470 610 770 950

AWGno.*) 18 18 18 18

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.
1 ) Halogenated type FMGCG will be substituted according to DIN, edition 1998 through the halogen-free type FMGCH. FMGCH-F with functionallity according to IEC 60331 available on request.

P 11

Marine Telecommunications Cables FMSGSGO


halogen-free, copper screened

Technical data
According to VG 95 218 part 62, screened. No loss of insulation if directly exposed to open flame. No special flame proof layer necessary Conductor operating temperature max. +858 C Nominal voltage 250 V Minimum bending radius approx. 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded copper conductors Heat resistant EPR-insulation 3GI3, to DIN VDE 0207 part 20 Cores quad twisted Filling compound covering all cores Overall copper braided screen Polyester foil taping Chloroprene based outer sheath 5GM3, to DIN VDE 0207 part 21, flame retardant and halogen-free sheath colour black Colour code All sizes and dimensions are colour coded.

Application
For fixed installation on marine craft above and below decks.

Part No. 59380 59381 59382 59383

No. cores x cross-sec. mm2 2 x 2 x 0,75 4 x 2 x 0,75 6 x 2 x 0,75 8 x 2 x 0,75

Outer 1 ca. mm 9,0 12,5 14,5 15,5

Cop. weight kg / km 89 142 189 225

Weight ca. kg / km 110 190 260 310

AWGno.*) 18 18 18 18

Part No. 59384 59385 59386

No. cores x cross-sec. mm2 10 x 2 x 0,75 14 x 2 x 0,75 16 x 2 x 0,75

Outer 1 ca. mm 17,0 18,5 20,0

Cop. weight kg / km 272 338 373

Weight ca. kg / km 380 465 520

AWGno.*) 18 18 18

Ferry line to Scandinavia

P 12

Marine Telecommunications Cables FMSGSGO 250V


with a single screen, higher cross-talk attenuation, halogen-free

Technical data
According to VG 95 218 part 63 Conductor operating temperature max. +858 C min. installation temperature 108 C Nominal voltage 250 V Minimum bending radius approx. 3 5 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Plain copper, stranded conductor Cross-linked polyolefin-insulation Cores laid up in pairs Separation foil Each pair plain copper wire screened Each pair with separation foil Pairs laid up concentrically Separation foil Overall foil wrap Plain, copper wire, braided screen Separation foil Elastomere based outer sheath, flame retardant and oil resistant sheath colour black

Application
For fixed installation on marine craft above and below deck.

Colour code for cores Pair/counting pair: black/blue Pair/counting direction pair: black/brown Subsequent pairs: black/grey

Part No. 59150 59151 59152 59153

No. cores x cross-sec. mm2 2 x 2 x 0,75 4 x 2 x 0,75 7 x 2 x 0,75 11 x 2 x 0,75

Outer 1 ca. mm 14 17 20 27

Cop. weight kg / km 149 277 489 658

Weight ca. kg / km 220 340 500 780

AWGno.*) 18 18 18 18

Part No. 59154 59155 59156

No. cores x cross-sec. mm2 14 x 2 x 0,75 19 x 2 x 0,75 24 x 2 x 0,75

Outer 1 ca. mm 28 32 37

Cop. weight kg / km 731 951 1181

Weight ca. kg / km 950 1300 1600

AWGno.*) 18 18 18

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P 13

Light Marine Telecommunications Cables LFMGSSGO


halogen-free, 2xcopper screened

Technical data
According to VG 95 218 part 64, 2 x copper screening. No loss of insulation if directly exposed to open flame. No special flame proof layer neccessary Conductor operating temperature max. +858 C min. installation temperature 108 C Nominal voltage 250 V Minimum bending radius approx. 6 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded (7) tinned copper conductor to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 Cross-linked polyolefin-insulation Core stranded to pairs with optimal laylength Overall halogen-free inner filling Tinned copper, braided double screening Polyester foil taping Elastomere based outer sheath, flame retardant and oil resistant sheath colour black Colour code for cores Pair/counting pair: black/blue Pair/counting direction pair: black/brown Subsequent pairs: black/grey

Application
For fixed installation on marine craft above and below decks.

Part No. 59390 59391 59392

No. cores x cross-sec. mm2 2 x 2 x 0,4 4 x 2 x 0,4 7 x 2 x 0,4

Outer 1 ca. mm 8,0 10,5 12,5

Cop. weight kg / km 60 95 146

Weight ca. kg / km 95 145 220

Part No. 59393 59394 59395

No. cores x cross-sec. mm2 12 x 2 x 0,4 19 x 2 x 0,4 27 x 2 x 0,4

Outer 1 ca. mm 15,5 18,0 20,0

Cop. weight kg / km 235 320 414

Weight ca. kg / km 320 415 540

P 14

Light Marine Telecommunications Cables LFMSGSSGO


halogen-free, 2xcopper screened

Technical data
According to VG 95 218 part 66, 2 x copper screening with improved cross-talk protection. No loss of insulation if directly exposed to open flame. No special flame proof layer necessary Conductor operating temperature max. +858 C min. installation temperature 108 C Nominal voltage 250 V Minimum bending radius approx. 6 x cable 1 Approved by r Wehrtechnik und BWB (Bundesamt fu Beschaffung), i.e. German Federal Office for Defence and Procurement

Cable structure
Stranded (7) tinned copper conductor Cross-linked polyolefin-insulation Core stranded to pairs with optimal laylength Tinned copper, braided screening over each pair Polyester foil seperator Overall polyester taped inner covering Tinned copper, braided overall screen Halogen-free insulating layer Overall tinned copper, braided screen Polyester foil separator Elastomere based outer sheath, flame retardant and oil resistant sheath colour black Colour code All sizes and dimensions are colour coded.

Application
For fixed installation on marine craft above and below decks.

Part No. 59396 59397

No. cores x cross-sec. mm2 5 x 3 x 0,4 12 x 3 x 0,4

Outer 1 ca. mm 16 23

Cop. weight kg / km 248 500

Weight ca. kg / km 420 740

P 15

Ships Wiring Cables - SY single cores

Technical data
special PVC single cores according to DIN VDE 0250 Temperature range flexing + 58 C to +708 C fixed installation 408 C to +708 C Nominal voltage 250 V Test voltage 1500 V Minimum bending radius approx. 7,5 x cable 1 Approved by Germanischer Lloyd

Cable structure
Fine wire stranded, plain copper conductors according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5 PVC core insulation Tinned steel-wire braided screening PVC outer sheath (RAL 7001) Sheath colour black Flame resistant and self-extinguishing as per VDE 0472, part 804, test B and IEC 60332-1 Oil resistant according DIN VDE 0250

Application
For installation in measuring and control units, for communication systems, production lines and conveyor belts. For fixed or mobile installation in dry, damp or wet areas. These PVC single cores are also suitable for use in ship building.

Part No. 59450 59451 59452 59453

No. cores x cross-sec mm2 1x6 1 x 10 1 x 16 1 x 25

Outer 1 ca. mm 8,3 10,3 10,3 13,7

Cop. weight kg / km 57,4 95,8 153,4 239,5

Weight ca. kg / km 148 221 293 447

AWGno.*) 10 8 6 4

Part No. 59454 59455 59456 59457

No. cores x cross-sec mm2 1 x 35 1 x 50 1 x 70 1 x 95

Outer 1 ca. mm 15,2 18,1 21,1 22,8

Cop. weight kg / km 335,0 479,5 671,0 910,0

Weight ca. kg / km 565 788 1061 1355

AWGno.*) 2 1 2/0 3/0

PVC cables will be changed to lead free PVC successively.

Container loading with bridge crane

P 16

Ships Wiring Cables - SY stranded type

Technical data
Special PVC cables Temperature range flexing + 58 C to +708 C fixed installation 408 C to +708 C Nominal voltage 250 V Test voltage 3000 V Minimum bending radius approx. 7,5 x cable 1 Approved by Germanischer Lloyd

Cable structure
Fine stranded, plain copper conductors according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5 PVC-based core insulation YI2 according to DIN VDE 0207 Cores colour coded to DIN VDE 0293 or black cores with continuous white numbering Core stranded in layers with optimal lay-length PVC inner sheath Galvanized steel-wire braided overall screening Outer sheath according to DIN VDE 0207 part 5 Sheath colour grey (RAL 7001) Conditionally oil-resistant Flame resistant and self-extinguishing as per VDE 0472, part 804, test B and IEC 60332-1

Application
The ideal cable for all fixed installations. These SY cables are also suited for use in production lines, conveyor systems, automatic assembly lines, etc. as well as in ship building. The tinned copper wire braiding offers excellent protection against both mechanical and electronic interference to the cable function.

Part No. 59460 59461 59462 59463 59464 59465 59466 59467

No. cores x cross-sec mm2 2 x 1,5 3 x 1,5 4 x 1,5 5 x 1,5 7 x 1,5 3 x 2,5 4 x 2,5 5 x 2,5

Outer 1 ca. mm 9,7 10,1 10,8 11,6 13,3 11,6 13,3 14,3

Cop. weight kg / km 28,7 43,1 57,5 71,9 100,6 72,1 95,8 120,0

Weight ca. kg / km 146 166 198 230 299 231 298 355

AWGno.*) 16 16 16 16 16 14 14 14

Part No. 59468 59469 59470 59471

No. cores x cross-sec mm2 4x4 5x4 4x6 5x6

Outer 1 ca. mm 16,2 17,5 18,4 19,7

Cop. weight kg / km 153,5 193,0 230,3 288,0

Weight ca. kg / km 358 535 595 714

AWGno.*) 12 12 10 10

PVC cables will be changed to lead free PVC successively.

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P 17

Ships Power Cables MPRX 0,6/1 kV


according to IEC 60092-353, halogen-free

Technical data
As per IEC 60092-353 Temperature range max. +858 C conductor temperature Min. installation temperature 108 C Nominal voltage U0/U 0,6/1 kV Bending radius approx. 4 x cable 1 Approved by Germanischer Lloyd, Lloyds Register of Shipping, American Bureau of Shipping, Det Norske Veritas, Bureau Veritas, Russian Maritime Register of Shipping and Registro Italiano Navale Flame retardant according to SOLAS definition (according to IEC 60332-3 category A and IEEE 45-18.13)

Cable structure
Stranded, bare copper conductors to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 Core insulation of cross-linked polyethylene Cores stranded in layers with optimal lay-length Outer sheath, Polyolefin basiscompound, jacket colour black Colour code 1 core: black 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/white 5 to 24 core cable: all cores black coloured, printed with numbers, starting in center with number 1

Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck. Therefore, these cables are especially suitable for the installation on passenger ships. Tests Flame-test to VDE 0472 part 804, test method C, IEC 60332-3 cat. A and IEEE 45-18.13 Smoke density to IEC 61034 Halogen-free to 60754-1 Corrosiveness of combustion gases to IEC 60754-2

Part No. 59654 59655 59656 59657 59658 59659 59660 59661 59662 59663 59664 59665 59666 59667 59668 59669 59670 59671 59672 59673 59674 59675 59676 59677 59678 59679 59680

No. cores x cross-sec. mm2 1x4 1x6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 2 x 25 3 x 1,5 3 x 2,5 3x4 3x6 3 x 10 3 x 16

Outer 1 ca. mm 5,9 6,4 7,3 8,2 10,1 11,1 12,8 14,9 16,7 18,6 20,7 22,9 25,7 28,4 7,8 8,9 9,9 10,9 13,0 15,1 17,6 8,3 9,4 10,4 11,8 13,8 16,1

Cop. weight kg / km 38 58 96 154 240 336 480 672 912 1152 1440 1776 2304 2880 29 48 77 115 192 307 480 43 72 115 173 288 461

Weight ca. kg / km 70 95 140 200 320 420 560 780 1030 1290 1590 1960 2560 3200 80 105 145 190 290 430 680 100 140 190 260 410 600

AWGno.*) 12 10 8 6 4 2 1 2/0 3/0 4/0 kcmil kcmil kcmil kcmil 16 14 12 10 8 6 4 16 14 12 10 8 6

Part No. 59681 59682 59683 59684 59685 59686 59687 59688 59689 59690 59691 59692 59693 59694 59695 59696 59697 59698 59699 59700 59701 59702 59703 59704 59705 59706

No. cores x cross-sec. mm2 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 4 x 1,5 4 x 2,5 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 5 x 1,5 5 x 2,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5 19 x 1,5 24 x 1,5

Outer 1 ca. mm 19,8 21,3 24,7 27,3 31,1 34,5 9,2 10,3 11,6 12,6 15,4 17,9 22,0 23,9 27,8 32,9 36,1 10,1 11,2 11,0 14,1 14,7 15,5 16,3 17,4 20,5

Cop. weight kg / km 720 1008 1440 2016 2736 3456 58 96 154 230 384 614 960 1344 1920 2688 3648 72 120 101 144 173 202 230 274 346

Weight ca. kg / km 970 1290 1720 2450 3305 4140 130 180 245 345 535 795 1300 1725 2310 3275 4445 165 225 205 290 330 375 440 500 630

AWGno.*) 4 2 1 2/0 3/0 4/0 16 14 12 10 8 6 4 2 1 2/0 3/0 16 14 16 16 16 16 16 16 16

300 350 500 600

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P 18

Ships Power Cables MPRXCX 0,6/1 kV


according to IEC 60092-353, halogen-free, screened

Technical data
As per IEC 60092-353 Temperature range max. +858 C conductor temperature Min. installation temperature 108 C Nominal voltage U0/U 0,6/1 kV Bending radius approx. 4 x cable 1 Approved by Germanischer Lloyd, Lloyds Register of Shipping, American Bureau of Shipping, Det Norske Veritas, Bureau Veritas, Russian Maritime Register of Shipping and Registro Italiano Navale Flame retardant according to SOLAS definition (according to IEC 60332-3 category A and IEEE 45-18.13)

Cable structure
Stranded, bare copper conductors to DIN VDE 0295 cl. 2, BS 6360 cl. 2 and IEC 60228 cl. 2 Core insulation of cross-linked polyethylene Cores stranded in layers with optimal lay-length Cores wrapping with fail Copper screened braiding Outer sheath, Polyolefin basiscompound, jacket colour black Colour code 1 core: black 2 cores: black/blue 3 cores: black/blue/brown 4 cores: black/blue/brown/white 5- to 24 core cable: all cores black coloured, printed with numbers, starting in center with number 1

Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck. Therefore, these cables are especially suitable for the installation on passenger ships. The good screening qualities of the copper braid also reduce radio interferences and electrical influences to electronic installations. Tests Flame-test to VDE 0472 part 804, test method C, IEC 60332-3 cat. A and IEEE 45-18.13 Smoke density to IEC 61034 Halogen-free to 60754-1 Corrosiveness of combustion gases to IEC 60754-2

Part No. 59707 59708 59709 59710 59711 59712 59713 59714 59715 59716 59717 59718 59719 59720 59721 59722 59723 59724 59725 59726 59727 59728 59729 59730 59731 59732 59733

No. cores x cross-sec. mm2 1x4 1x6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10 2 x 16 2 x 25 3 x 1,5 3 x 2,5 3x4 3x6 3 x 10 3 x 16

Outer 1 ca. mm 7,3 7,8 8,9 9,8 11,7 12,7 14,8 16,9 18,7 20,6 22,7 24,9 27,2 30,4 3,9 10,2 11,4 12,6 14,8 16,9 20,4 9,9 10,8 12,0 13,2 15,7 18,0

Cop. weight kg / km 81 104 149 214 311 416 572 779 1034 1316 1615 1968 2506 3345 105 132 170 217 307 471 670 125 161 215 282 417 636

Weight ca. kg / km 105 130 180 250 380 480 660 900 1170 1410 1750 2160 2770 3440 130 160 205 290 400 560 840 160 200 250 360 520 750

AWGno.*) 12 10 8 6 4 2 1 2/0 3/0 4/0 kcmil kcmil kcmil kcmil 16 14 12 10 8 8 4 16 14 12 10 8 6

Part No. 59734 59735 59736 59737 59738 59739 59740 59741 59742 59743 59744 59745 59746 59747 59748 59749 59750 59751 59752 59753 59754 59755 59756 59757 59758 59759

No. cores x cross-sec. mm2 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 3 x 120 4 x 1,5 4 x 2,5 4x4 4x6 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 5 x 1,5 5 x 2,5 7 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5 19 x 1,5 24 x 1,5

Outer 1 ca. mm 21,7 23,1 26,5 29,1 32,9 36,7 10,6 11,9 13,0 14,6 17,3 19,8 23,9 25,7 29,6 33,7 38,3 11,7 12,8 12,5 16,0 16,6 17,4 18,2 19,3 22,4

Cop. weight kg / km 924 1233 1703 2413 3192 3975 147 190 284 371 545 796 1170 1578 2278 3090 4110 171 220 209 318 353 394 432 486 601

Weight ca. kg / km 950 1470 1870 2650 3500 4300 200 240 350 450 670 950 1470 1930 2500 3550 4600 225 330 310 400 440 500 550 620 770

AWGno.*) 4 2 1 2/0 3/0 4/0 16 14 12 10 8 6 4 2 1 2/0 3/0 16 14 16 16 16 16 16 16 16

300 350 500 600

*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 see page T 15.

P 19

You might also like