N302

N304

N308

T302

T304

T305

T307

T308

D2000 D2000 D2000

3 3 3

D2000 D2000 D2000

3 3 3

D30 D30 D30

D30 D30 D30

D40 D40 D40

1 1 1

UCONNMODETIMER

T309
5 5 5

N312

N313

N315

T312

T313

T314

T315

T316

6 6 6

D1 D1 D1

10 10 10

D100 D100 D100

D0 D0 D0

D0 D0 D0

D1 D1 D1

D30 D30 D30

D600 D600 D600

T381

D1 D1 D1

N381

INVALID INVALID INVALID

T323

1 2 3 5 5 5 2 2 2 5 5 5 180 180 180 1 2 3 UCOIFTIMER

MML_RNCID

CHANNELRETRYTIMERLEN

CHANNELRETRYHOTIMERLEN

RABMODIFYTIMERLEN

ZERORATEUPFAILTORELTIMERLEN

MML_RNCID

MML_RNCID

D2000 D2000 D2000

3 3 3

6 6 6

D1 D1 D1

1 2 3

UIDLEMODETIMER

1 3 1 2 1 3

UIUTIMERANDNUM

CNOPINDEX
0 0 0 0 0 0

CNID

N300

N312

T300

T312

2 2 2 2 2 2

30000 30000 30000 30000 30000 30000

120000 120000 120000 120000 120000 120000

20000 20000 20000 20000 20000 20000

20000 20000 20000 20000 20000 20000

60000 60000 60000 60000 60000 60000

1 1 2 2 3 3

20 20 20

UPSINACTTIMER

PSINACTTMRFORCON

STATEINDTMR

RSTRSNDNUM

MML_RNCID

RAFCTMR

RATCTMR

IGORTMR

INTRTMR

UPSINACTTIMER 20 20 20

PROTECTTMRFORCON

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

PSINACTTMRFORSTR

PROTECTTMRFORSTR

PSINACTTMRFORINT

PROTECTTMRFORINT

PSINACTTMRFORBAC

PROTECTTMRFORBAC

PSINACTTMRFORIMSSIG

PROTECTTMRFORIMSSIG

360 360 360

PSINACTTMRFORPREFSTDRM

4 4 4 10 10 10 1 2 3 5000 5000 5000

PSINACTTMRFORFSTDRMDCH

PSINACTTMRFORFSTDRMFACH

MML_RNCID

USTATETIMER

RRCUERSPTMR

5000 5000 5000 350 350 350 5000 5000 5000

RRCIURELCMDTMR

RRCRELRETRANTMR

RRCPAINGTYPE1TMR

5000 5000 5000

RRCINITDTTMR

1000 1000 1000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000

RRCRLCACKCMPTMR

RBSETUPRSPTMR

UECAPENQRSPTMR

RBRECFGRSPTMR

RBRELRSPTMR

RLSETUPRSPTMR

RLRECFGREADYTMR

RLRELRSPTMR

11000 11000 11000

RLRSTRTMR

5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000

DRLAAL2ESTINDTMR

DRLRECFGCMITTMR

HOCELLUPDATERSPTMR

HORELOCREQTMR

HOPAGINGRSPTMR

HOASUTMR

HOWTTRCHRECFGRSPTMR

HOPHYCHRECFGTMR

10000 10000 10000

RELOCCMDTMR

45000 45000 45000 20000 20000 20000 5000 5000 5000 15000 15000 15000 5000 5000 5000 5000 5000 5000 10000 10000 10000 5000 5000 5000

RELOCIURELCMDTMR

RELOCDATAFWDTMR

RELOCANOTHERTMR

RELOCCOMMITTMR

RELOCMOBILCONFTMR

RELOCPHYCHRECFGTMR

RELOCUTRANHOCMPTMR

RELOCFAILIURELCMDTMR

10 10 10

SYSHOPSRESUMETMR

5000 5000 5000 5000 5000 5000 5000 5000 5000 300 300 300 300 300 300 4 4 4 1 2 3

RRCSECRTMODECMPTMR

UECNTCHECKRSPTMR

CMCHRSRCRSPTMR

IUCSRELNORABTMR

IUPSRELNORABTMR

RRCCONNREJWAITTMR

MML_RNCID

CELLRESELECTTIMER

180 180 180

CELLRESELECTTIMER

65535 65535 65535 5 5 5 5 5 5 180 180 180 2 2 2 5 5 5 180 180 180 5 5 5

UUESTATETRANSTIMER

BEF2PSTATETRANSTIMER

BED2FSTATETRANSTIMER

BEH2FSTATETRANSTIMER

RTDH2FSTATETRANSTIMER

BEE2FSTATETRANSTIMER

BECPC2FSTATETRANSTIMER

RTCPC2FSTATETRANSTIMER

BED2EFACHSTATETRANSTIMER

5 5 5 180 180 180 5 5 5 180 180 180 1 2 3

BEH2EFACHSTATETRANSTIMER

RTDH2EFACHSTATETRANSTIMER

BECPC2EFACHSTATETRANSTIMER

RTCPC2EFACHSTATETRANSTIMER

MML_RNCID

TIMER T302 N302 T304 N304 T305 T307 T308 N308 T309 T312 N312 T313 N313 T314

T315

N315

T316

T381 N381

T323

Details T302 is started after the UE transmits the CELL UPDATE/URA UPDATE message and stopped after the UE receives the CELL UPDATE CONFIRM/URA UPDATE CONFIRM message. CELL UPDATE/URA UPDATE will be resent upon Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 3. T304 is started after the UE sends the UE CAPABILITY INFORMATION message and stopped after the UE receives the UE CAPABILITY INFORMATION CONFIRM message. UE CAPABILITY INFORMATION will be resent upon the expiry of the timer if V304 less than or equal N304; otherwise the cell update procedure will be initiated. Maximum number of retransmissions of UE CAPABILITY INFORMATION. Protocol default value is 3 T305 is started after the UE receives CELL UPDATE CONFIRM/URA UPDATE CONFIRM in CELL_FACH, URA_PCH or CELL_PCH state. It is stopped after the UE enters another state. CELL UPDATE will be transmitted upon the expiry T307 is started after T305 has expired and the UE detects "out of service area". It is stopped after the UE detects "in service area". The UE will enter idle mode upon expiry. T308 is started after the UE transmits RRC CONNECTION RELEASE COMPLETE. This message will be sent upon the expiry of the Timer if V308 less than or equal to N308, otherwise, the UE will enter idle mode. Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 1 T309 is started after the UE is reselected to a cell belonging to another radio access system in connected mode, or the CELL CHANGE ORDER FROM UTRAN message is received. It is stopped after the UE is successfully connected in the new cell. The UE will continue the connection to UTRAN upon expiry. Protocol default value is T312 is started when UE starts to establish a DCH, and stopped when UE detects consecutive N312 "in sync" indications from L1. It indicates physical channel setup failure upon the expiry of the timer. Maximum number of successive "in sync" indications received from L1. T313 is started after the UE detects consecutive N313 "out of sync" indications from L1. T313 is stopped after the UE detects consecutive N315 "in sync" indications from L1.It indicates Radio Link (RL) failure upon expiry. Maximum number of successive "out of sync" indications received from L1. T314 is started when the criteria for radio link failure are fulfilled and only radio bearers (RBs) associated with T314 exist.T314 is stopped after the Cell Update procedure has been completed. In case of the RL failure when the UE is in CELL_DCH state, If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T314 (or T315), CELL UPDATE will be resent for RL reconfiguration (this operation T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer associated with T315 exists.T315 is stopped after the Cell Update procedure has been completed. In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE is sent. If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T315 should be set greater than T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer associated with T315 exists.T315 is stopped after the Cell Update procedure has been completed.In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE is sent. If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T315 should be set greater than T316 is started after the UE detects "out of service area" in URA_PCH or CELL_PCH state.T316 is stopped after the UE detects "in service area".The cell update procedure will be initiated upon the expiry of the timer if "in service area" is detected; otherwise, T317 will be started. The UE will enter CELL_FACH state and initiate cell T381 is started after the RNC send message "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM"). If T381 expire and RNC does not receive "RRC CONNECTION SETUP COMPLETE"(or the response of "CELL UPDATE CONFIRM") and V381 is smaller than N381, RNC resend "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM") and restart timer T381 and increase V381. If RNC receive "RRC CONNECTION SETUP COMPLETE"(or the response Maximum number of resend times of message "RRC CONNECTION SETUP" or "CELL UPDATE CONFIRM". default

If the UE checks that no PS/CS data is transmitted, the UE will send the SIGNALLING CONNECTION RELEASE INDICATION message to the RNC, informing the RNC to terminate the PS data session. Meanwhile, the UE starts T323. The UE shall be inhibited from sending the SIGNALLING CONNECTION RELEASE INDICATION message with the IE "Signalling Connection Release Indication Cause" set to "UE Requested PS Data session end" whilst timer

Default Value Recommended D2000 3 D2000 3 D30 D30 D40 1 5 6 D1 10 D100 D0

D0

D1

D30

D600 D1

INVALID