List of Corrections in IS 800:2007 Submitted for consideration at the meeting of BIS committee CED:7 on 1st October, 2010, at BIS,

, Chennai No Page Clause/Table/Fig Currently reads as Change to Section 17 Fabrication (17.15 missing) 17.15 Bedding requirement 1 iii and Erection 21st symbol Cmy, Cmz moment Kz, Ky, KLT moment 2 6 explanation amplification factors amplification factors (Cl. 4.4 about respective axes and Cl. 9.3.2.2) Table 2: Web of an I, H or box section but 42 3 18 but 42 Generally (under Class 1, Class 2 and Class 3) Table 2 Ratio for stem 4 18 D/tf d/t of a T-section 5 18 Table 2 Last line overll overall Figure for ROLLED 6 19 Depth is marked as h Should be d CHANNELS 7 24 Cl 4.4.2, Cl 4.4.3.1 Cy,Cz Ky,Kz 8 24 Cl 4.4.3.3 Cmy, Cmz Ky,Kz 9 25 Cl.4.5.2 b) 12th line IS 2062 shall not be than IS 2062 shall not be less than Cl 5.6.1 Deflection. 2nd Table 6 gives Table 6 gives recommended column 6th line recommended limits of limits of deflections for deflections for certain certain structural members structural members and and systems. In Table 6, Live 10 31 systems. Circumstances load should include all post may arise. construction loads including super imposed dead loads (SIDL). Circumstances may arise. Cl. 6.3.3 (max. value of fu mo/fy m1 0.9 fu mo/fy m1 11 33 beta) Cl. 7.1.2 First line The design compressive The factored design strength Pd ,of a member compression, P, in the 12 34 is given by : members shall satisfy the following requirement: 13 34 Cl: 7.1.2.1 last line m0 m0 14 35 Fig.8 Abscissa (X- axis) title Table 10 Limits for 15 44 40 mm < tf 100mm 40 mm < tf 100mm Rolled I- sections Table 11, Boundary at I Column II column I Column II column 16 45 one end 2nd Case Free Restrained Restrained Free 17 48 Cl. 7.5.1.2 end of the first para e as given below e as given below, in place of in 7.1.2.1 and use curve c (=0.49)

Cl. 7.5.1.2

Rewrite the equations for vv = =

18

48

19 20 21

49 53 57

Top figure in Fig.10 Cl. 8.2.1.1 3rd line Table 14 Heading 1st para 3rd and 4th line

22

58 1st para last three lines

23

58

24 25 26 27

58 58 59 60

28 29 30 31 32 33 34

60 60 60 60 61 62 62

Cl. 8.3.2 9th line Table 15 Case iii) under warping restraint Cl 8.4.2.1 Cl. 8.4.2.2 a) Definition of cr,e = the elastic tcr,e critical shear stress of the web Second column second b buckling strength as line obtained from 8.4.2.2.(a) rd Cl.8.5.1 3 line Carried in accordance Definition for )

Correct the horizontal axis as z-z and vertical axis as y-y. d/tw 67 d/tw > 67 KL/r LLT/ry h/tf hf/tf length for lateral length for lateral torsional torsional buckling to be buckling, LLT, to be used in used in 8.2.2.1 LLT shall 8.2.2.1 shall be be The effective length shall In the case of intermediate be equal to 1.2 times the partial lateral restraints, the length of the relevant effective length, LLT, shall be segment in between the taken as equal to 1.2 times the lateral restraints length of the relevant segment in between the partial lateral restraints at the shear and is at the shear centre and is Both flanges fully Both flanges partially restrained restrained and fy Read all as w and fy as fyw cr,e Repeated and hence treat that as deleted. Carried out in accordance = nearly equal to

Cl 8.4.4.2(b) Table 16 (last row under top restraint conditions) Fig. 12 NOTES Item no 2 for

wtf=dcos+(c-sc-st)sin i) Free

wtf=dcos-(c-sc-st)sin The figure should be without top flange restraint The dimension is c Panel B is designed using

Dimension arrow Panel B is designed

Figure 12

without utilizing the tension field action as given in 8.4.2.2.(a) All occurrences of When c < d f = yield stress ratio of web for n 0.2 Mndy=Mdy for n > 0.2 Mndy=1.56 Mdy (1-n)(n+0.6) Mndz=1.11Mdz(1-n) Mdz

simple post critical method as given in 8.4.2.2.(a) Treat item 2 as deleted and item 3 becomes item 2 w When c < 0.74d f = yield stress ratio of flange Mndz=1.11 Mdz (1-n) Mdz for n 0.2 Mndy=Mdy for n > 0.2 Mndy=1.56 Mdy (1n)(n+0.6) 0.2 (-)-0.8s 0.4 h 0.95 0.90+0.1 h(1+2 ) Vsb Vdb Design for friction type bolting where slip resistance is required at factored design force Vsf shall satify the following f 0.55 Vnsf 0.9fubAnfybAsb(m1/m0) fbr2 E250B steel of IS:2062 or steel meeting the requirement of Charpy E>27 J. 690 si = (ui Li )/ hi (LLT)2

35 36 37 38

63 63 63 64

NOTES item no 2 for Figure 13 Cl.8.6.1.1 a) and b) Cl.8.6.1.1 b) 3) Cl. 8.6.1.2 last line Cl. 9.3.1.2 c) for standard I or H sections

39

70

40 41 42 43 44

72 72 72 72 75

45

76

46 47 48 49

76 76 77 80

50 51 52 53

89 106 121 128

Table 18(4th column, 0.2(1- )-0.8s 0.4 th 6 row) Table 18(2nd column,6th s th & 7 rows) Table 18(4th column, 0.095 th th 7 & 8 row) Table 18 (5th column, 0.90+0.05 h(1+2 ) th 9 row) Cl.10.3.2 Vsb = Vdb Cl 10.4.3 Slip Design for friction type Resistance bolting in which slip is required to be limited, a bolt subjected only to a factored.. Cl 10.4.3 definition of f=0.55 f Cl.10.4.3 NOTE: Vns th Page 77 6 line 0.9fubAnfybAsb(m1/m) Cl. 10.5.10.2.2 second term in the equation fbf2 under the square root sign Cl.12.8.2.1 E250B steel of IS:2062 only 12.11.1 Cl.16.4.1 value in denominator B-3.2 equation and definitions of terms (add suffix i) E-1.2 equation for Mcr 905 s = (u L) / h (LLT)

54 55 56 57 58

128 129 130 130 130

E-1.2 equation for yj Definition It Table 42 6th column 5th row Table 42 6th column 7th row Table 42 6th column 10th row

(z2-y2) It = torsion constant 1.780 1.257 1.390

(z2+y2) It = St. Venants torsion constant 1.730 1.267 1.890