Opvaskemaskine LF 019SX

PV IMPORT a/s GRSDALSVEJ 20 8800 VIBORG

S A T

Sec.
Length

PJ1 - 2.5 colour N BLACK 1 BLUE 2 GREEN 3 0.35 1710 0.35 1710 0.35 1710

PJ2 Colour N BROWN 4 BLUE 5 BLUE 6

Sec.

Length

1.5 1.5 1.5 BROWN 1.5 7 RED 0.5 8 9 WHITE(SN) 1.5 10 WHITE (SN) 1.5

220 220 170 160 160 130 130

STOCKO CONNECTOR

PJ3 Colour N 11 RED 12 BROWN WHITE 13 WTHIE 14 15 PINK PINK 16 BLUE 17 BLUE 18

Sec.

Length

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

190 190 1690 1690 1880 1880 500 500

STOCKO CONNECTOR

STOCKO CONNEC.

STOCKO CONNECTOR

CONNECS.

STOCKO CONNEC.

STOCKO CONNECTOR

ELBI CONNEC.

DISPLAY CARD

STOCKO CONNECTOR

C Fagor Electrodomesticos, S. Coop.


Sec.
Length

STOCKO CONNECTOR

STOCKO CONNECTOR STOCKO CONNECTOR

PJ4 Colour N 19 WHITE 20 WHITE 21 BROWN 22 BROWN 23 ORANGE 24 ORANGE 25 GREEN 26 GREEN

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

785 785 1055 1055 605 605 665 665

2006
SIGNAL COMMUN MOTEUR
VISIBLE SIDE TRANSPARENT P.V.C

Sec.

Length

PJ5 - 2.5 Colour N 27 BLACK BLACK 28 29 GREEN GREEN 30 BLUE 31 BLUE 32

0.35 0.35 0.35 0.35 0.35 0.35

880 880 1280 1280 180 180 PJ6 Sec. Length Colour N ORANGE 33 0.5 480 WHITE 0.5 485 34 YELLOW 0.5 490 35

Colour

Sec.

Length

BLUE BLUE

www.fagor.com

PJ7 N 36 37

0.5 0.5

540 540
Sec.
Length

PJ8 - 2.5 Colour N RED 38 GREEN 39 WHITE 40

0.35 570 0.35 570 0.35 570

Colour

Sec.

Length

WHITE WHITE

VJ2 N 41 42

0.5 0.5

350 350

CLOUDINESS SENSOR FAN ALTERNATIVE VALVE DETERGENT/RINSE AID DISPENSER FILL VALVE LOCKING CLAMPS FOR 4 mm. DIAM. HOLE REGENERATION VALVE SAFETY MICRO STANDARD MICRO SWITCH DOOR MICRO SWITCH WATER PRESSURE MICRO SWITCH MICRO SWITCH NUMBERING HEATING ELEMENT DRAIN PUMP CONDENSER WASH PUMP CONNECTOR SALT INDICATOR STOCKO CONNECTOR RINSE AID INDICATOR SAFETY THERMOSTAT CONNECTOR BLOCK TANK EARTH FLOW THROUGH HEATER DOOR EARTH WASH PUMP EARTH SUPPLY EARTH

N9886

S A T

S A T

www.fagor.com

N9882

FAGOR INNOVATION 2006 ECO - ALTA


PROGRAMMES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 7 6 5

VERSION:

??

DATE :

11/01/2006

FUNCTIONS
4 3 2 1 0

USER

FAGOR

OUTPUTS

CONDITION FOR STEP

PROGRAMME STEP

OTHERS

MOTOR DISTIRBUTOR CYCLE

PROGRAMME STEP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92

DOUBLE INTENSIVE 7 0C

DETERGENTE - RINSE AID

REGENERATION VALVE

NORMAL 65 AUTOMATIC 55C-65C

AUTOMATIC 55C-65C

HEATING ELEMENT

CHECK 55C

DRAIN PUMP

RELIABILITY

RUNNING

PREWASH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

TEMP [C]

TIME (seg) 30

ACT MNV TF DS2 TF TF MNI TIME_TEMP TF MNV TF TF TF MNI TF TF TF TIME_TEMP TEMP TF TF DS2 MNV TF TF DS2 TF TF MNI TF TEMP TIME_TEMP TIME_TEMP TIME_TEMP TIME_TEMP TIME_TEMP TIME_TEMP TIME_TEMP TF TIME_TEMP TF TF TF TF TF DS2 MNV TF TF TF DS2 TF TF MNI TF DS2 MNV TF TF DS2 TF TF MNI TF DS2 MNV TF TF DS2 TF TF MNI TEMP TIME_TEMP TF TIME_TEMP TIME_TEMP TIME_TEMP TF TF TEMP TEMP TEMP TEMP TF DS2 MNV TF TF TF TF TF TF DS2 MNV TF TF REIN IO STOP DRAIN

RFT

RFT

RFT

RFT

RFT

RFT

25 15 40 480 30 30 25 15 300 180 720 600 60 15

TIME ADJUSTMENT

HIGYENIZER 75C

INTENSIVE 70C

DELICATE 45C

EXPRESS 40C

ENDURANCE

WASH PUMP

MOTOR FAN

MIXED 50C

FILL VALVE

PREWASH

ECO

FILL

55 75 TUR AS AS AS AS TUR AS AS AS AS AS AS AS AS TUR AS AS AS AS AS AS AS AS TUR AS AS AS AS AS AS AS AS TUR AS AS AS AS TUR AS AS AS AS

V V V V V V

C C C C C C

WASH

10 20

DRAIN

WASH 1
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 AS AS AS AS AS AS AS AS

WASH 1
AS AS AS AS 75 68 65 55 52 55 45 40 52 25 15 60 720 1020 720 900 600 300 300 120 1320 900 300 1200 600 180 FILL

AS | NE+ AL | E+

AS AL

RE

RE

RE

RE

RE

RE

RE

RE

RE

RE

RE

RE

RT

RT

RT

RT

RT

RT

V V V V V V V V V V V V V V V V

C C C C C C C C C C C C C C C

WASH

RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1

RE? 4:1 RE? 4:1 RE? 4:1 RE? 4:1

10 40 20

DRAIN

RINSE I
50 51 52 53 54 55 56 57 58

RINSE I
25 15 360 FILL WASH DRAIN

10 20

RINSE II
59 60 61 62 63 64 65 66 67

RINSE II
25 15 360 FILL WASH DRAIN

10 20

RINSE III
68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87

RINSE III
25 15 75 40 4:1 4:1 4:1 4:1 NE+ 4:1 4:1 4:1 4:1 4:1 65 55 45 FILL

240 60 480 360 240 240 120

E+ NE+

E+ NE+

55 65 68 73 30

V V V V V V V V V V V V V

C C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1

DRAIN

20

DRY
88 89 90 91 92 93 94 95 96 97 98 RT RT RT RT RT

DRY
600 1800 840 120 60 DRY

END OF PROGRAMME

END OF PROGRAMME
20 1800 93 DRAIN 94 95 96 97 END PROGR 98

Si

Notes on PROGRAMMES: R Temperature mantained at -3C C Alternate wash 10s/50s C1 RE Electronic regeneration RT Short wash AS Dirty water AL Clean water RFT Water cloudiness TUR Water cloudiness 4:1 4-in-1 option activated E+ ECO PLUS option activated NE+ ECO PLUS option not activated

Programme Express 40. Alter loading it only washes with the upper distributor, DS3 Notes on STEP CONDITIONS DS1, DS2, DS3 and DS4 are the four preset stopping positions for the distributor. They are all set as the position the distributor reaches 0,1 seconds after a single micro switch contact has opened, and they are differentiated by the time this contact remains closed. The nominal contact closing times preceding each stopping position are as follows : : The motor distributor completes a full turn in 15 seconds F=50Hz TDS1 = 0,62 - 0,93 se TDS2 = 1,00 - 1,35 se TDS3 = 1,45 - 1,80 se TDS4 = 1,85 - 2,20 se Lower Open Closed 1/2 Open Closed F=60Hz TDS1 = 0,51 - 0,77 sec TDS2 = 0,83 - 1,12 secc TDS3 = 1,21 - 1,50 sec TDS4 = 1,54 - 1,83 sec C 50s 50s 10s 10s

SALT REGENERATION (Regeneration EV) When Option 4 EN 1 is activated: .- Subtract 1 from the Regeneration value entered by the User (and store on Power Board-M) .- The value entered by the User will appear on the Interface Board (Slave).

BASIC FUNCTION

ia-M

4-in-1:
When this option is activated:
- Skips the RINSE III step - On WASH 1 phase .- THE NON-REGENERATION MODELSskip this step .-THE REGENERATION MODEL ...performs the step according to the SALT REGENERATION note.

CHECK COMPILE

DS2 DS3 DS4 DS1

Closed Open Closed 1/2 Open

Fill/drain posit.

Lower DS2 Open DS3 Closed DS4 1/2 Open DS1 Closed

Upper Closed Open Closed 1/2 Open

C1 60s 120s 0s 0s

MN full means the level micro switch is indicating full (contact closed) V ( Monitoring ) : When the MN is full, if this signal is lost , the fill valve is activated until the contact closes again MMN empty means the micro switch level is indicating empty (contact open)

Strictly speaking, STOP is not a step condition. It means that the step counter is place Strictly speaking, RESTART is not a step condition. It means the step counter goes to 0

FOR SUPER INTENSIVE, INTENSIVE, AUTOMATIC AND MIXED PROGRAMMES THE CLOUDINESS SENSOR MUST BE READ ON PREWASH, TO DECIDE WHETHER TO USE THE SAME WATER FOR WASHING ON AUTOMATIC IT WOULD ALSO WASH AT 55 OR 65 IF IT DOES NOT HAVE A SENSOR, THE AS STEPS ARE PERFORMED HEATING ELEMENT The heating element is connected until the step condition temperature setting is reached. It is then switched off. If the step condition includes another type of condition (e.g. time) apart from a temperature setting: .- When the temperature setting is reached, the heating element switches off .- Except when R is indicated, in which case the temperature regulation is done with hysteresis

C Fagor Electrodomesticos, S. Coop.

2004

S A T

S A T

www.fagor.com

N9893

C Fagor Electrodomesticos, S. Coop.

2004

S A T

S A T

PJ2

1 2 3 4 5

NEUTRAL LINE

HEATER PRESSURE-SW

RAST-516A

PJ3

WASHING_ PUMP

DOOR

LINE

1 2 3 4 5 6

DETERGENT

C Fagor Electrodomesticos, S. Coop.


IC2 1 2 3 4 5 7 9 DIS-DRV FAN-DRV EVF-DRV EVR-DRV DET-DRV WP-DRV 16 15 14 13 12 11 10 1C 2C 3C 4C 5C 6C 7C GND ULN200A4 COM 1B 2B 3B 4B 5B 6B 7B 8

EDGE

PJ4

LINE DRAIN-PUMP SAFETY SWICH NEUTRAL

EV-FILL

2006

1 2 3 4 5 6 7 8

EV-REG

EDGE

PJ6

DISTR_POS

www.fagor.com

1 2 3 4

DISTRIBUTOR LINE

EDGE

PJ7

1 2

LINE DRYING_FAN

EDGE

N12372

S A T

906012941 [1LF-019SX] - FAGOR - 02-04-2007 Pos. 1 2 2 3 3 4 5 7 8 10 11 11 14 16 16 17 18 19 20 21 23 24 25 26 29 32 33 38 41 42 43 43 44 45 49 51 55 56 57 59 60 61 62 69 70 72 73 77 80 81 82 83 86 90 91 92 93 95 96 97 98 99 100 103 105 106 111 112 113 Reference LV0861000 V53B000T0 V53B000U6 VF9B000A5 VF9B000B1 LV0860500 V87B000C0 V66B000B5 VA9B000D3 VA9B000H7 VA9B000E9 VA9B000G1 V19C000D7 V53B000G5 V53B000L4 V19C000B6 V21B000A7 VE8A000M5 VC5A000E3 VC5A000F9 VE5A001F8 VE5A001G4 V09A000P9 V67A002F6 VF8A000N6 V70R146R8 V58X000R5 V72B000G9 V87A000E5 VF6A000G0 VC4B000A9 VC4B000B5 VF0000026 V64I000H5 VB3B000B1 LQ1A000A1 VH7A000I1 V77I000E6 VL4S000E2 VH2A000F5 VH2A000E9 VH2B000B8 VC5A000G5 LV0655100 LV0860300 V87A000S6 VG8A000U3 Z02K039A4 VH2B000G7 VH2B000F1 LV0655900 LV0655200 V24A000Z0 VI8I000F3 V36H000P3 V35A002A3 V23A000E0 VJ7A000N1 LV0861200 VC6A000D5 LV0656700 V87B000E1 VH6I000D0 V23I000C5 V12B001C9 VJ1A000J1 V99I000H1 VC8B000F9 VC8B003A4 Description HOTPLATE EXTENSION EXTENSION GUIDE RAIL GUIDE RAIL MOTOR UNIT SEAL CATCH BEARING RACK GUIDE RAIL END STOP END STOP COVER SIDE PANEL SIDE PANEL EXTENSION ADJUSTABLE FOOT PAN SEAL FIXING FILTER FILTER UNIT CLOSURE UNIT DOOR PLINTH CONTROL PANEL KEY DOOR SEAL SEAL SPRING MOVING HINGE MOVING HINGE INSIDE DOOR FEEDER LOWER DOOR SEAL BENDER DRAIN PIPE WATER INTAKE HOSE DISTRIBUTOR CAP NUT DECALCIFIER SEAL SEAL NON-RETURN UNIT SEAL INNER PIPE SCREW AIR BREAK NUT REED SEAL PAN PIPE FILTER SWITCH POWER CABLE MICRO LEVELLING UNIT PUMP UNIT SUPPORT WOBBLER SEAL CONDENSER MICRO HEATER UNIT CUTLERY DRAIN PUMP UPPER BASKET FOLDING ADJUSTABLE From Until

20-03-2006 20-03-2006

Pos. 115 116 117 118 119 120 122 123 124 125 126 128 130 132 134 142 144 154 156 161 162 166 167 168 169 170 172 176 176 177 184 187 188 190 190 191 191 192 193 195 196 198 200 228 229 230 231 232 233 235 236 239 240 241 243 244 245 247 248 250 251 254 255 262 263 264 265 266 268 269

Reference VH1A000N3 VE2A000J0 VH5A000B5 VD9A000L1 V58X000E9 VJ7A000L0 LV0655300 LV0656100 V23I000E6 VL1A000A1 VK9A000A8 LV0162600 V03E000D5 VJ7A000P3 V54M006A9 VE7B000A3 LV0861300 V92B000C7 Z02K037A8 Z02K042A5 LV0656200 LV0654800 LV0653800 VE4A000G9 VE4A000H5 VA5A000K6 VJ1A000E2 V92B000A5 V92B000B1 VA5A000M8 V19C000F9 V19C000A0 LV0656300 VA5A000E1 VF2B000B6 VJ8A000N9 VJ8A000P1 VJ8A000M4 VC8A000M4 LV0655600 VC4B000C1 VF9B000C7 V28F013A5 VE8A000N0 VJ1A000K7 VC4B000F8 VL8A000B2 VC4B000E2 V87B000B4 VK2A000C5 Z02K038A6 V21B000C9 V19C000C2 VC8B002A6 V87B000D5 V21B000I3 V21B000H8 VH2B000E5 VG8A000X0 LV0858700 VB3B000C7 V72C000A0 V72C000B6 V02A000C9 V58X000F5 V58X000G1 V54M000A2 V81A000E8 V10J000A9 V10J001J9

Description LOWER BASKET WHEEL FUNNEL CUTLERY KEY LEVER O-RING SUPPORT MICRO GRILLE SUPPORT SEAL COVER FLOAT CONTROL CIRCUIT FIXING LEVER SPACER SCREW SCREW THERMOSTAT ELECTROVALVE REED SHAFT SUPPORT PIPE SUPPORT HINGE HINGE DISTRIBUTOR COVER BASE SUPPORT DISTRIBUTOR UNIT SPRINKLER LIFTING UNIT LIFTING UNIT WHEEL SUPPORT THERMOACTUATOR SPACER REGULATOR USER MANUAL SUPPORT ROD CORD PROTECTOR FASTENING SEAL COVER SCREW MECHANISME COVER HANDLE SEAL NUT SHAFT FAN COVER SEAL SUPPORT EXTENSION EXTENSION COUNTERWEIGHT KEY KEY POWER CIRCUIT GUIDE RAIL CONNECTOR ELECTRICAL INSTALLA