VENTURI SCRUBBER SYSTEM


MODEL: AP 02

HIS Venturi Scrubber System (Model: AP 02) has been manufactured to a high standard with emphasis on ease of use and operational safety. It consists of mainly a transparent cylindrical venturi, a separation chamber, a water re-circulation system, a dust feeding system, and a variable speed air blower. Instruments for the measurement of the incoming air flow and pressure drops across the convergence and divergence sections of the venturi are provided. The unit has been designed for student demonstration on dust pollution control using a venturi scrubber.

The venturi section is made of durable clear PVC with throat diameter of 32 mm and both convergence and divergence diameter of 101.6 mm. The separation chamber is also made of durable clear PVC measuring approximately 0.6 m diameter and 2 m tall. The chamber has a rectangular tangential inlet at the bottom that is connected to divergence section of the venturi. A mist eliminator at the top section of the chamber prevents any water droplets from escaping. The water re-circulation system consists of a water tank, a water pump, a liquid flow meter, a pressure gauge and a pressure regulator.

An air blower installed at the outlet is capable of drawing 280 m3/hr of air through the system. The air inlet velocity can be varied by means of adjusting the air blower speed. A dust feeding system is provided for introducing a desired amount of dust particles into the air stream before entering the separation chamber. A differential pressure instrument is provided for the purpose of measuring pressure drop, P, across the venturi.

SOLTEQ

Equipment for Engineering Education & Research

EXPERIMENTAL CAPABILITIES To study the effect of liquid-to-gas (L/G) ratio upon separation efficiency. To verify the theoretical relationship between total pressure drop, P and inlet velocity, vi. SPECIFICATIONS A skid-mounted venturi scrubber unit for demonstration on dust pollution control consisting of a transparent venturi and a separation chamber vertically mounted on sturdy frames. The frames are epoxy painted for good look, durability and ease of maintenance. The unit comes complete with a water re-circulation system, a high-pressure blower, an air flow meter, and a feeding system. Process pipings are made of PVC and stainless steel. VENTURI: cylindrical shape made of durable clear PVC; total length: 0.62 m; throat dia. (ID): 32 mm; convergence/divergence dia. (ID): 101.6 mm; convergence angle: 10.5; divergence angle: 5; pressure drop tappings at the convergence and divergence sections. SEPARATION CHAMBER: cylindrical chamber made of durable clear PVC. Size: 0.6 m (dia.) x 2 m (H). Comes with tangentially mounted rectangular inlet and stainless steel mist eliminator. WATER RE-CIRCULATION SYSTEM: 55-L rectangular tank made of stainless steel fitted with level switch; centrifugal pump with 25 LPM capacity; liquid flow meter with 0 to 10 LPM range. AIR BLOWER: 1 unit of 5 hp high-pressure blower; maximum capacity @ 3,400 rpm: 280 m3/hr; withstand a static pressure of 80 inches of water; electrical: 415V/ 3-phase/50Hz; comes with inverter for regulating the blower speed.

FEEDING SYSTEM: 1 unit of clear PVC cylinder with conical bottom and flow regulating valve. DIFFERENTIAL PRESSURE: 2 units of analog differential pressure gauges. Panel mounted type. Range: 0 to 100 cm of water and 0 to 25 cm of water. OPTIONAL ITEMS

- EI DIGITAL INSTRUMENTATIONS i) 2 units of Digital Indicators with selector switch ii) 3 units of Differential Pressure Transmitter iii) 1 unit of Liquid Flow meter - DAS SOLDAS DATA ACQUISITION SYSTEM i) A PC with Pentium processor ii) A signal conditioning unit iii) A stand alone data acquisition modules iv) A Windows based software Data Logging Signal Analysis Process Control Real-Time Display Tabulated Results Graph of Experimental Results - CAL SOLCAL COMPUTER AIDED LEARNING SOFTWARE i) Interactive Multimedia Features ii) Graphical Simulation iii) Typical Experiment Results iv) Full Experiment Manuals

REQUIREMENTS

Dust particles sample. Digital balance: 5,000 g; accuracy: 0.01g. Ventilated working area: approx. 10 m2. Electrical: 415V/3-phase/50Hz.

SOLTEQ

Student will demonstrate dust pollution control using a venturi scrubber and study the effect of liquid-to-gas (L/G) ratio upon separation efficiency.

AIR FLOW METER: A venturi type flow meter with differential pressure gauge. DP range: max 16 inch of water.

SOLTEQ
OVERALL DIMENSIONS Height Width Depth

Equipment for Engineering Education & Research MANUAL The unit is supplied with Operating and Experiment manuals in English.

: 2.75 m : 2.45 m : 1.22 m

SCHEMATIC DIAGRAM

SOLTEQ

Equipment for Engineering Education & Research

SOFTWARE & E - LEARNING Our range of teaching equipment can be complemented with our SOLDAS and SOLCAL software.

SOLDAS - Supervisory Control & Data Acquisition - Data Logging - Signal Analysis - Process Control - Real-Time Display - Tabulated Results - Graph of Experimental Results

SOLCAL - Computer Aided Learning - Multimedia Features - Interactive - Graphic Simulation - Experiment Result Samples - Full Experiment Manuals

Contact us for a catalog CD SOLUTION ENGINEERING SDN. BHD.


(Co. No. 174876-M) Sales Office : No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara, 47100 Puchong, Selangor Darul Ehsan, Malaysia. Tel. No. : +(603) 80758000 Fax. No. : +(603) 80755784 R&D Office : G-2A, Incubator 3, Technology Park Malaysia, Bukit Jalil, 57000 Kuala Lumpur, Malaysia. Tel. No. : +(603) 8996 0023 Email : solution@solution.com.my Web site : http//www.solution.com.my/ MSC- Status