NATIONAL BUILDING CODE 2005

INDUS Enviro Confidential 1

Topics Covered

National Building Code 2005

Fire Safety and Emergency Exit Requirements

Lift and Staircase Enclosures


Electrical Safety

INDUS Enviro Confidential 2

Relevant Regulations

National Building Code 2005

National Building Code 2005

INDUS Enviro Confidential 3

Definitions
Building Any structure for whatsoever purpose and of whatsoever materials constructed and every part thereof whether used as human habitation or not and includes foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms, VERANDAH, balcony, cornice or projection, part of a building or anything affixed thereto or any wall enclosing or intended to enclose any land or space and signs and outdoor display structures. Tents, SHAMIANAHS, tarpaulin shelters, etc, erected for temporary and ceremonial occasions with the permission of the Authority shall not be considered as building Fire Lift The lift installed to enable fire services personnel to reach different floors with minimum delay, having such features as required in accordance with this Part

Refuge Areas are such areas in a building where people can take shelter in case of a fire
INDUS Enviro Confidential 4

Definitions
Escape Lighting: That part of emergency lighting which is provided to ensure that the escape route is illuminated at all material times, for example, at all times when persons are on the premises, or at times the main lighting is not available, either for the whole building or for the escape routes Fire Exit Away out leading to an escape route having panic bar hardware provided on the door Lightning Arrestor means a device which has the property of diverting to earth any electrical surge of excessively high amplitude applied to its terminals and is capable of interrupting flow current if present and restoring itself thereafter to its original operating conditions

INDUS Enviro Confidential 5

Fire Safety
Fire-Fighting Equipment
Fire fighting equipment shall be distributed all over the building in proportion to the area & occupancy on every floor, basement, lift room, etc. in accordance with IS: 2217 & IS: 2190 specifications

Portable extinguishers should be so located, that the base of these should be 75 Cm above the floor level
Premises shall be protected by wet riser/wet riser-cum- down comer, automatic sprinkler/high pressure water spray or foam generating system

Wet riser in the building should be arranged by means of vertical rising mains with hydrant & hose reel on each floor landing connected to an overhead water storage tank for fire fighting purpose should be present
Water in the fire tanks shall exclusively be used for fire fighting & is not to be utilized for domestic or any other use.
INDUS Enviro Confidential 6

Fire Safety
Fire-Fighting Equipment
Water capacity of terrace and underground storage tank should be as per Table 23. For ex. A business building above 30m ht. shall have 2,00,00L water in underground storage tank at a pressure of 3.5 Kg/cm2. OR water capacity of 20,000L at the terrace level with pressure of 2.5 Kg/cm2.

IS: 3644 specifications, Code of practice for installations, of internal fire hydrants in multi storied high rise buildings should be adhered to
All first-aid fire fighting equipment shall be placed in a conspicuous position and shall be readily and easily accessible for immediate use All water buckets and pump type extinguishers shall be filled with clean water. All sand buckets shall be filled with clean, dry and fine sand. All water and sand buckets shall be painted red Each first-aid fire-fighting equipment shall be allotted a serial number by which it shall be referred to in the records
INDUS Enviro Confidential 7

Fire Safety
Fire-Fighting Equipment

INDUS Enviro Confidential 8

striving for excellence in sustainability services


INDUS Enviro Confidential 9