GE Consumer & Industrial Power Protection

New

Entelliguard G
Power Circuit Breaker Uncompromising, Fast & Selective
GE imagination at work

EntelliGuard G

Performance Ratings

2 6 7 13

Performance Ratings Product Identication Features Total Solution

The breaker Order Codes Electronic Trip Units Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

Intro A B C D E F X

EntelliGuard G
EN 60947-2 standard
Power Circuit Breaker type Air Circuit Breaker Denomination Poles Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Ue Category of use Suitable for use as an isolator Rated current In Ultimate breaking capacity Icu [kA] Number of Ui (Volts) Uimp [Kilovolt] Volts AC Volts DC Positive ON & OFF A at 50C 230/240V-440V AC 500V AC 690V AC 1000V AC (4) 230/240V-440V AC 500V AC 690V AC 1000V AC (4) 1 second 3 seconds kA Peak With Maintenance Without Maintenance Without Maintenance 250V DC 1 pole 500V DC 2 poles 750V DC 3 poles GG04 H E M S N 3.4 1000 1250 1000 1250 1000 12 690 1000 690 1000 690 750 750 B YES 400 50 65 85 85 100 50 65 50 65 65 85 100 50 65 40 50 65 85 85 40 50 35 50 50 65 85 85 100 50 65 50 65 65 85 100 50 65 40 50 65 85 85 40 50 35 50 50 65 65 85 85 50 65 40 50 50 50 50 40 50 105 143 187 187 220 105 143 20000 20000 10000 20000 12500 10000 5000 12500 10000 10000 5000 10000 50 65 35 50 20 35 S N GG07 H E M S N 3.4 1250 1000 1250 1000 12 1000 690 1000 690 750 750 B YES 630 85 85 100 50 65 65 85 100 50 65 65 85 85 40 50 35 50 85 85 100 50 65 65 85 100 50 65 65 85 85 40 50 35 50 65 85 85 50 65 50 50 50 40 50 187 187 220 105 143 20000 10000 20000 10000 5000 12500 10000 5000 10000 50 65 35 50 20 35 GG08 H E M 3.4 1250 1000 1250 12 1000 690 1000 750 750 B YES 800 85 85 100 65 85 100 65 85 85 35 50 85 85 100 65 85 100 65 85 85 35 50 65 85 85 50 50 50 187 187 220 20000 10000 10000 5000 10000 5000 50 65 35 50 20 35

EntelliGuard G

Service breaking capacity Ics [kA]

Short-circuit Withstand Icw (kA) Short-circuit Making current Icm 220-500V AC Mechanical Endurance (CO operations at 440V AC) Electrical Endurance (CO operations at 440V AC) Ultimate breaking capacity Icu [kA] = Service breaking capacity Ics (kA) DC L/R = 15ms (nr. of poles in series) (1)

EntelliGuard G Electronic Trip Units (1)

Intro A B C D E F X

GT -E type with Ammeter GT -S type with Ammeter, optional communication GT -N type with Measurement, optional communication GT -H type with Measurement & Relaying, optional communication

LT & ST, - GF LT, ST, I or HI - GF LT, ST, I or HI, RELT GF, ZSI LT or LT+, ST, I or HI, RELT GFsum or GFct., ZSI

X X X X

X X X X

X X X X

EN 60947-3 standard
Power Circuit Breaker type Isolator Denomination Poles Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Ue Category of use Suitable for use as a isolator Rated current In Short-circuit Withstand Icw (kA) Short-circuit Making current Icm 220-500V AC Mechanical Endurance (CO operations at 440V AC) Electrical Endurance (CO operations at 440V AC) N 3.4 1000 1000 12 690 690 B YES 400 50 65 40 50 88.2 143 20000 12500 10000 S GJ04 Non Auto Number of Ui (Volts) Uimp [Kilovolt] Volts AC Volts DC Positive ON & OFF A at 50C 1 second 3 seconds kA Peak With Maintenance Without Maintenance Without Maintenance M 3.4 1250 12 1000 750 B YES 400 85 50 187 20000 10000 10000 N 3.4 1000 1000 12 690 690 B YES 630 50 65 40 50 105 105 20000 12500 10000 S GJ07 Non Auto M 3.4 1250 12 1000 750 B YES 630 85 50 187 20000 10000 10000 N 3.4 1000 1000 12 690 690 B YES 800 50 65 40 50 105 105 20000 12500 10000 S GJ08 Non Auto M 3.4 1250 12 1000 750 B YES 800 85 50 187 20000 10000 10000

Installation
Fixed Pattern Dimensions in mm Height Width 3 pole Width 4 pole Depth (2) Rear Horizontal Rear Vertical Front 3 pole 4 pole Height Width 3 pole Width 4 pole Depth (2) Rear Universal (3) Front 3 pole 4 pole 442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100 442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164 442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100 442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164 442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100 442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164

Available Connection modes Weights in Kg Draw out Pattern Dimensions in mm

Available Connection modes Weights in Kg (1) (2) (3) (4)

For dc applications a special Trip Unit is required With Horizontal Rear Connections; Indicated depth value is the required panel dimension T stubs can be rotated and used for both Vertical & Horizontal Rear Connection For use at 1000V phase seperators are required

EntelliGuard G
S 1000 690 N GG10 H 3.4 1250 12 1000 750 B YES 1000 85 65 65 35 85 65 65 35 65 50 187 E 1000 690 M 1250 1000 750 S 1000 690 N GG13 H 3.4 1250 12 1000 750 B YES 1250 85 65 65 35 85 65 65 35 65 50 187 E 1000 690 M 1250 1000 750 S 1000 690 N GG16 H 3.4 1250 12 1000 750 B YES 1600 85 65 65 35 85 65 65 35 65 50 187 E 1000 690 M 1250 1000 750 S 1000 690 N GG20 H 3.4 1250 12 1000 750 B YES 2000 85 65 65 35 85 65 65 35 65 50 187 E 1000 690 M 1250 1000 750

50 50 40 50 50 40 50 40 105

65 65 50 65 65 50 65 50 143 20000 12500 10000

85 85 85 85 85 85 85 50 187 20000 10000 10000

50 35 20

100 100 85 50 100 100 85 50 85 50 220 10000 5000 5000 65 50 35

50 50 40 50 50 40 50 40 105

65 65 50 65 65 50 65 50 143 20000 12500 10000

85 85 85 85 85 85 85 50 187 20000 10000 10000

50 35 20

100 100 85 50 100 100 85 50 85 50 220 10000 5000 5000 65 50 35

50 50 40 50 50 40 50 40 105

65 65 50 65 65 50 65 50 143 20000 12500 10000

85 85 85 85 85 85 85 50 187 20000 10000 10000

50 35 20

100 100 85 50 100 100 85 50 85 50 220 10000 5000 5000 65 50 35

50 50 40 50 50 40 50 40 105

65 65 50 65 65 50 65 50 143 20000 12500 8000

85 85 85 85 85 85 85 50 187 20000 10000 6000

50 35 20

100 100 85 50 100 100 85 50 85 50 220 10000 5000 5000 65 50 35

Performance Ratings

X X X X

X X X X

X X X X

X X X X

Intro A
M 3.4 1250 12 1000 750 B YES 2000 85 50 187 10000 5000 5000

GJ10 Non Auto S 3.4 1000 12 690 B YES 1000 50 65 40 50 88.2 143 20000 12500 10000 690 1000 N M 3.4 1250 12 1000 750 B YES 1000 85 50 187 20000 10000 10000 S 3.4 1000 12 690 B YES 1250 50 65 40 50 105 105 20000 12500 10000 690 1000 N

GJ13 Non Auto M 3.4 1250 12 1000 750 B YES 1250 85 50 187 20000 10000 10000 S 3.4 1000 12 690 B YES 1600 50 65 40 50 105 105 20000 12500 10000 690 1000 N

GJ16 Non Auto M 3.4 1250 12 1000 750 B YES 1600 85 50 187 20000 10000 10000 S 3.4 1000 12 690 B YES 2000 50 65 40 50 88.2 143 20000 12500 8000 690 1000 N

GJ20 Non Auto

B C D E

442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100

442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164

442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100

442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164

442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100

442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164

442 342 442 328 X X X 43 54 444 343 443 453 X X 82 100

442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164

F X

EntelliGuard G
GG25 GG32 & GH32 (4) H M N H M G Number of 3.4 3.4 Ui (Volts) 1000 1250 1000 1250 1000 Uimp [Kilovolt] 12 12 Volts AC 690 1000 690 1000 690 Rated operational voltage Ue Volts DC 750 750 B B Category of use Positive ON & OFF YES YES Suitable for use as an isolator A at 50C 2500 3200 Rated current In 230/240V-440V AC 65 85 100 65 85 100 100 500V AC 65 85 100 65 85 100 100 Ultimate breaking capacity Icu [kA] 690V AC 50 85 85 50 85 85 100 1000V AC (6) 50 50 230/240V-440V AC 65 85 100 65 85 100 100 500V AC 65 85 100 65 85 100 100 Service breaking capacity Ics [kA] 690V AC 50 85 85 50 85 85 100 50 50 1000V AC (6) 65 85 85 65 85 85 100 1 second Short-circuit Withstand Icw (kA) 3 seconds 50 50 50 50 50 50 85 143 187 220 143 187 220 220 Short-circuit Making current Icm 220-500V AC kA Peak With Maintenance 20000 10000 20000 10000 10000 Mechanical Endurance (CO operations at 440V AC) Without Maintenance 10000 5000 10000 5000 5000 Electrical Endurance Without Maintenance 6000 5000 5000 5000 2500 (CO operations at 440V AC) 250V DC 1 pole 50 65 Ultimate breaking capacity Icu [kA] 35 50 = Service breaking capacity Ics (kA) DC L/R 500V DC 2 poles = 15ms (nr. of poles in series) (1) 750V DC 3 poles 20 35 Power Circuit Breaker type Air Circuit Breaker Denomination Poles Rated insulation voltage Rated impulse withstand voltage N

EN 60947-2 standard

EntelliGuard G

GG40 & GH40 (4) H M G 3.4 1250 1000 1250 1000 12 1000 690 1000 690 750 750 B YES 4000 150 65 85 100 100 130 65 85 100 100 100 50 85 85 100 80 50 150 65 85 100 100 130 65 85 100 100 100 50 85 85 100 80 50 100 65 85 85 100 85 50 50 50 85 330 143 187 220 220 10000 20000 10000 10000 5000 10000 5000 5000 L N 2500 65 50 35 5000 65 50 35

L 1250 1000 750

150 130 100 80 150 130 100 80 100 85 330 10000 5000 65 50 35

GG50 M L 3.4 1000 1250 12 690 1000 750 B YES 5000 100 150 100 130 100 100 80 100 150 100 130 100 100 80 100 100 85 85 220 330 10000 10000 5000 5000 65 50 35

GG64 M L 3.4 1000 1250 12 690 1000 750 B YES 6400 100 150 100 130 100 100 80 100 150 100 130 100 100 80 100 100 85 85 220 330 10000 10000 5000 5000 65 50 35

5000 2500 2500 1500 1500 1500 1500

EntelliGuard G Electronic Trip Units (1)

Intro A B C D E F X

GT -E type with Ammeter GT -S type with Ammeter, optional communication GT -N type with Measurement, optional communication GT -H type with Measurement & Relaying, optional communication

LT & ST, - GF LT, ST, I or HI - GF LT, ST, I or HI, RELT GF, ZSI LT or LT+, ST, I or HI, RELT GFsum or GFct., ZSI

X X X X

X X X X

X X X X

X X X X

X X X X

EN 60947-3 standard
Power Circuit Breaker type Isolator Denomination Poles Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Ue Category of use Suitable for use as a isolator Rated current In N 3.4 1000 12 690 B YES 2500 65 50 143 20000 10000 6000 GJ25 Non Auto Number of Ui (Volts) Uimp [Kilovolt] Volts AC Volts DC M 3.4 1250 12 1000 750 B YES 2500 85 50 187 10000 5000 5000

Positive ON & OFF A at 50C 1 second Short-circuit Withstand Icw (kA) 3 seconds Short-circuit Making current Icm 220-500V AC kA Peak With Maintenance Mechanical Endurance (CO operations at 440V AC) Without Maintenance Electrical Endurance Without Maintenance (CO operations at 440V AC)

GJ32 & GK32 (4) Non Auto N M 3.4 3.4 1000 1250 12 12 690 1000 750 B B YES YES 3200 3200 65 85 50 50 143 187 20000 10000 10000 5000 5000 5000

GJ40 & GK40 (4) Non Auto N M 3.4 3.4 1000 1250 12 12 690 1000 750 B B YES YES 4000 4000 65 85 50 50 143 187 20000 10000 10000 5000 5000 5000

GJ50 Non Auto L 3.4 1250 12 1000 750 B YES 5000 100 85 220 10000 5000 1500

GJ64 Non Auto L 3.4 1250 12 1000 750 B YES 6400 100 85 220 10000 5000 1500

Installation
Fixed Pattern Dimensions in mm Height Width 3 pole Width 4 pole Depth (2) Rear Horizontal Rear Vertical Front 3 pole 4 pole Height Width 3 pole Width 4 pole Depth (2) Rear Universal(3) Front 3 pole 4 pole 442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164 (3) (4) (5) (6) 442 432 562 328 X X X 53 68 444 443 573 453 X X 131 164 442 737 967 328 X X 90 115 444 743 973 488 X 220 275 442 432 562 328 X X 53 68 444 443 573 488 X (5) X 131 164 442 737 967 328 X X 90 115 444 743 973 488 X 220 275 442 737 967 328 X X 90 115 444 743 973 488 X 220 275 442 737 967 328 X 90 115 444 743 973 488 X (5) 220 275

Available Connection modes Weights in Kg Draw out Pattern Dimensions in mm

Available Connection modes Weights in Kg

(1) For dc applications a special Trip Unit is required (2) With Horizontal Rear Connections; Indicated depth value is the required panel dimension

T stubs can be rotated and used for both Vertical & Horizontal Rear Connection GH and GK types (100% rated types) are only available in draw out pattern in vertical connection mode T stubs can only be used for vertical Rear Connections For use at 1000V phase seperators are required

EntelliGuard G
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5

Intro A B C D E F X

Performance Ratings

EntelliGuard G
Product Identication
Power Circuit Breaker Front Facia
1 2 3 4 5 6 7

EntelliGuard G

8 9 10

Installed Accessory Indicators Electronic Trip Unit Manual Charging Handle ON and OFF Buttons Contact Position Indicatior Ready to Close Indicator Spring charged Indicator Operation Counter Prevision for Key Lock Global Catalogue Number

Intro A B C D E F X

SET UP METER STATUS EVENTS

EntelliGuard G G GG20H1XXGXXX2XX03

Power Circuit Breaker label


1 2 3 4 5 6 7 8

Product Type Bar code with Manufacturing data Colour Code indicating Interruption Tier Voltage Ratings Current Ratings Certication & Standards Short-circuit Interruption data Manufacturing Date

Advanced Electronic Trip Unit


1

2 3 4

Main Screen with the Following choices: Setup Allows adjustment of values and setting of all Parameters Meter Full measurement values are displayed Status Breaker and Trip Unit position Events History of Trips with indication of fault reason and level and access to the Waveform Capture function Cursor driven setting system Manual or Automatic Reset Choice Full Range Rating Plug

EntelliGuard G
Power Circuit breakers Uncompromising Fast & Selective

Intro A B
EntelliGuard G Power Circuit Breakers are a new line of Air Circuit Breakers evolved from the existing M-PACT & ME07 types to offer a truly global product platform meeting IEC, ANSI and UL standards. A line of Three and Four pole devices ranging from 400 to 6400Amp in three basic envelopes with fault interruption ratings of up to 150kAmps. A design offering a unique combination of High Fault current withstand ratings, short fault interruption time and selectivity. The device includes the new state-of-the-art EntelliGuard G trip unit that enables the circuit breaker with the latest technology for system safety, reliability, measurement, relaying and communications using the Modbus or Probus Protocol.

Features C
Contents
Hi-Performance Complete Line Selective and fast Uncompromising State of the Art Protection The Global Trip Unit Easy to use & Flexible Installation options Common, Field Mountable Accessories A Full Solution for Low Voltage Distribution

D E F X

Catalogue Content This catalogue only refers to the IEC versions of the EntelliGuard G Power Circuit Breaker. For the ANSI and UL variants of the same design please contact GE Consumer & Industrial Plainville CT U.S.A.

EntelliGuard G
Hi-Performance: Complete Line
Hi-Performance: Complete Line The EntelliGuard G range of Power Circuit breakers encompasses a line of Three and Four pole Air Circuit Breakers with Nominal Currents ranging from 400 to 6400Amp in three basic envelopes. All Power Circuit Breakers are designed to allow multiple interruptions of fault currents. Here the tested and certied Service Breaking capacity value is in all cases equal to the stated Ultimate Breaking Capacity.

EntelliGuard G

Envelope 1 can be used in networks with voltages up to 1000V and can be acquired with current ratings from 400 to 2000Amps at 50C. This type is available in interruption ratings (Ics=Icu) of 50, and 65kA. A version suitable for DC applications is available. Envelope 2 can be used in networks with voltages up to 1000V and can be acquired with current ratings from 400 to 4000Amps at 50C. This type is available in interruption ratings (Ics=Icu) of 50, 65, 85 and 100kA. A version suitable for DC applications is available.
150 150 140 140 130 130 120 120 110 110 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0

Intro A B C D E

Available Interruption tiers

Envelope 3 can be used in networks with voltages up to 1000V and can be acquired with current ratings from 3200 to 6400Amps at 50C. This type is available in interruption ratings (Ics=Icu) of 100 and 150kA. A version suitable for DC applications is available.

Envelope 2000A lcu=lcs


S N

Envelope 4000A lcu=lcs


H

Envelope 6400A lcu=lcs


M L

8000 7000 6000 5000 4000 3000 2000 1000 40C 50C Ambient temperature 55C 60C 65C 70C

Hi-Performance: Current Ratings in Enclosures One of the most important user parameters is not the nominal rating of an Air Circuit Breaker in free air but its current Rating within a panel or enclosure. Breakers enclosed ratings are determined by the heat dissipation produced by the device and its ability to carry current at the temperature within the enclosure. EntelliGuard G Power Circuit breakers have been designed with low Power dissipation values and allow relatively high currents at high ambient temperatures. This is applicable for breakers in the xed and Draw out Pattern as indicated in the graph insert. For extreme cases a special dual cluster draw out version of an Envelope 2 breaker is available allowing a very limited derating when the breaker is used at high ambient temperatures within an enclosure.

F X

Current

Envelope 3 Envelope 2 dual cluster

Envelope 2 single cluster Envelope 1

Standard Draw out Construction Single Cluster

Limited de-rating Draw out Construction Dual Cluster

EntelliGuard G
Selective, Fast & Uncompromising
10000 2h

EntelliGuard GT Electronic Trip Unit


Time Current Curve Breaker In =2500A Ir =2160A LT - Device ST - Device I - Device HSIOC -Device

Selective & Fast EntelliGuard G has been designed to offer an uncompromising combination of a fast interruption at high fault levels attaining values of 40 Milliseconds or less whilst maintaining selectivity. Power Circuit Breakers are designed to remain closed on a fault. This for at a user settable time value when the fault level lies within the range of the Short Time Delayed protection device AND for 15 Milliseconds when the fault level attains the Instantaneous protection range value.

1000

100

10

Tripping Time In Seconds (s)

This Instantaneous device includes programming that in normal circumstances waits until the downstream breaker trips.

Features

0,1

Speed WHEN needed ... Warrantied selectivity elsewhere The simplest, standard, Electronic Trip Unit, has a broad range of timed bands at all overcurrent levels. Thus attaining selectivity between closely rated devices and across multiple distribution levels. This strongly simplies and economizes installation design.

0,01

The depicted curves only indicate the Full Clearing time 10000 100000
]

1000

Current in Amps

1. 2. 3. 4.

Overload Protection (LT) with 44 bands Timed Short-circuit Protection (STD) with 17 bands Selective Instantaneous Protection (I) Hi-Speed trip (HSIOC)

Intro A B C D E F

Uncompromising ... Reliability EntelliGuard G has been designed as a Modern Power Circuit Breaker without neglecting its and GEs heritage of more than 50 years in building Air Circuit Breakers. These Power Circuit Breakers uncompromisingly combine the properties of the older Mpact 1 and 2, ME07 and Wavepro lines with modern state of the art technology. The result: a device that with a proven Electrical and Mechanical life span independent of its operation mode. Be it manual, electrical or by means of the installed Shunt and/or Undervoltage releases.

Uncompromising ... Safety In order to protect Service Personnel against the hazards of Short Circuits whilst working on a Power Distribution system EntelliGuard G Power Circuit breakers can be equipped with a so called RELT switch input. This allows the breaker to be switched to its lowest Short-circuit settings on service, thus limiting the hazards concerned. The RELT switch input (with feedback) is available on the breaker auxiliary terminals or can be accessed through the communication bus.
STDB 17 timing options from 90 to 1000 Milliseconds 0,1 Iselective Trips within 50-60 Milliseconds

Seconds (s)

IRELT Trips within 40-50 Milliseconds

IHI Speed Trips within 40 Milliseconds

0,01 1000 10000 Amps 100000

EntelliGuard G
Protection with State of the Art Trip Units
State of the Art Electronic Trip Unit All EntelliGuard G Power Circuit Breakers are equipped with a digital electronic trip unit, available in four basic versions: E, S, N and H. Each has a common design that comes with a screen providing an ammeter and allowing a simple and accurate menu-driven adjustment of the breaker parameters across a broad current range. All functionality is menu-driven accessed by using 4 setting and one enter key thus allowing a fast and accurate setting of the device. The user can set the device to an automatic or manual reset after a fault. After inserting the rating plug, the device can be adjusted and the installed options set. As this normally occurs when the installation is not powered up, the use of the separately available TESTER with Power Pack is advised.
EntelliGuard GT Electronic Trip Unit
10000

EntelliGuard G

Main adjustment Options LT-LTD protection Each device has an overload of settings or LT setting range of 0.2 to 1 times with a choice of more than 60 setting points. The Overload device has 44 time band settings allowing one to congure this device for almost any perceivable application. ST-STD protection A time delayed Short-circuit protection is installed with an adjustment range of 2 to 12 times the set LT current values. The Short-circuit interruption time can be set, at one of 17 bands ranging from 90 Milliseconds to 1 second. I protection A switchable instantaneous protection can be optionally installed. This device is adjustable from 2 to 15 or 30 times the rating of the breaker and is programmed to wait for downstream devices to trip before reacting. Other protection features A host of other protection devices as LT-B & LT-C, RELT, GF sum & GF source return plus the optional use of energy curves are available (See section B of this catalogue).

LT Protection 0.2 -1 x In

Intro A B

1000

100

LTD 44 bands

10

ST Protection 2- 12 x Ir STD 17 bands With/Without I2T I Protection 2-15 x In

C D E F X
SET UP METER SET UP VOLTAGE STATUS L1L2EVENTS L3Tripping Time In Seconds (s)
0,1

0,01

0,001 1000 10000 100000


]

x Current in Amps

Measurement, Relaying & Communication The EntelliGuard G Trip Unit has been envisaged to provide the user with more. Optionally a full network measurement device can be installed on the device. Relays can be included to trip the breaker on Voltage Unbalance, Current Unbalance, Power reversal etc. The device can be equipped with Communication for use with the Modbus or Probus protocol whilst events as Overload, Short-circuit and Groundfaults can be tracked. Optionally the user can portray a Shortcircuit event through the Wave Form Capture option. Plug n Play Electronic Trip Units are normally supplied factory tted. However spares are available that plug into the breaker, automatically read the main breaker data and adjust themselves automatically to the breaker type. This option can be used to allow Field replacement or Upgrades of existing Trip Units OR can allow the user to acquire Breakers in kit form and customize them locally.

REAL SET UP POWER PHA/L1 SET UP CURRENT 700kW PHA/L1PHB/L2APPR 350A SET UP POWER 300A PHB/L2PHA/L1 PHC/L3300A 750kVA 320A PHC/L3PHB/L2 320A 480kVA PHC/L3 220kVA

10

EntelliGuard G
Power Circuit Breakers Easy to Install & Versatile
Easy to Install
Stan ard Depd th

EntelliGuard G Power Circuit Breakers are available in a Fixed and Draw out Pattern. Each pattern offering the highest possible current rating when enclosed in a panel or equipment. Independent of the number of poles, rated current or interruption rating, each of the two patterns has a common height, depth and cut out dimension. This strongly simplifying the design of panels and equipment in which these devices are used(1). The basic breaker width has been optimized to allow for space to connect in- and outgoing bus bars and cables. Both Fixed and Draw Out Power Circuit Breaker types are supplied with rear connections suitable for Rear Access Horizontal busbar connection. The breakers are installed by using easily accessible mounting brackets, the drilling pattern of which exactly matches that of the previous Mpact line(2). All accessories are wired out to an easy to access 39 or 78 pole terminal strip mounted on the breaker top. These terminals are amply sized to allow the use of up to 2.5mm2 cabling and can be used with standard connection materials or AMP type plug connectors.

Standard Heigth

Intro A

Features B C D

Flexible ... Kit Form A Power Circuit Breaker is normally supplied completely tted OFF works. However the unique modular construction and eld mountable Trip Unit and Accessories option can be used to acquire a breaker in kit form and to customize the device locally(3).

Flexible ... Connections Besides the standard horizontal connection options multiple other options are available. B Power Circuit Breakers supplied in a xed pattern can be optionally supplied with Rear Vertical connections or Front access connections(4). The Cassettes of the Breakers in Draw out pattern are supplied with T or L stubs suitable for Horizontal Bubar connection. However these stubs can be rotated 90 degrees allowing the user to change the cassette connection option from Horizontal to Vertical Busbars. A 2nd cassette version is available allowing Front access Connection(4).

E F X

A Standard Horizontal Rear Connections B Mounting Bracket C Terminal strip

(1) (2)

The width does vary Except the new reduced size Envelope 3 type (3) With GE training (4) Maximum 4000Amps

11

EntelliGuard G
Common Field Mountable Accessories
Common Internal Accessories A large range of internal accessories as Electrical Operators (1), up to four Shunt Releases, Closing Coils or Undervoltage releases, Interlock Coils, Auxiliary and Alarm contacts, Carriage switches, Coil indication contacts and Breaker status switches are available. The Power Circuit Breaker front Facia includes Pop up indicators that provide the user with an overview as to which accessories are installed in the device.

EntelliGuard G

Each of these devices can be acquired factory tted or is available in a eld mountable execution. The design is common to all three envelopes.

Intro A
1

2 3 4 5 6

B C D E F X

Electrical Operator Bell Alarm Switch A max of 4 Closing Coils, Shunt or Undervoltage releases Electronic Trip Unit A maximum of 8 Auxiliary Switches Ready to close or Spring Charged contact

Common External Accessories Multiple common external accessories are available, a full overview of which can be found in section C of this catalogue. On the left the Key lock and breaker interlock options are portrayed. Here up to four Ronis, Profalux or Castell locks can be used to lock the breaker, and up to two Ronis or Profalux locks to lock the draw out breaker in its cassette. Optionally groups of two or three Power Circuit Breakers in Fixed or Draw out pattern can be interlocked. This in several different congurations, allowing the user to build an incoming power supply of multiple breakers to his own requirements. All Interlocks and Locking devices are only supplied factory tted, the associated locks and cables are Field mountable.

(1)

Electrical Operator design is equivalent, however 1 type exists for Envelope 1 and 1 for Envelope 2 & 3.

12

EntelliGuard G
Power Circuit Breakers Part of a total solution
Using w world class design and development tools like Six Sigma, Computer Simulation and Lean Manufacturing, the EntelliGuard G is intended to Simula and exceed the most stringent quality and safety standards. meet a At GE we w are proud to offer a product that will offer years of reliable and dependable protection. depend name is synonymous with a broad range of products designed to GEs na our customers changing and competitive environment. Our drive to meet o exceed our customers expectations is the foundation for continual renewal of our commitment to provide innovative low voltage solutions. renewa

Total Solution

The new ne EntelliGuard G and the existing Elfa Plus, Record Plus and Surion Breaker and starter lines offer a full line of high-performance protection devices. protec Provide a fully co-ordinated approach to circuit and device They P protection for use in the Domestic, Commercial and Industrial protec environment. environ new lines meet the latest technical standards and regulations and GEs ne been certied by authorities as Lovag, the KEMA and Lloyds. have b in these lines have been designed to be an integral The components co part of a solution. A complete low voltage distribution and control range including components, accessories and the distribution and controls includi equipment they t into. equipm

Intro A B C D E F X

13

EntelliGuard G

EntelliGuard G

Intro A B C D E F X

Application Software The new HD 384 (1) and R064-03 standards require that the design of a low voltage distribution system includes the determination of all prospective short-circuit and fault currents levels. GE Power Controls has developed a windows based software package to do this Procera Plus: A multi-standard and multi-lingual software package to accompany our new product line.

Design Software GE provides a software package PowerDesign to congure the widely used & well known GE system enclosure ranges Modula630K, ModulaPlus and SEN Plus, and to use them with components as Electrical Distribution panels. The software provides the user with a varied and simple range of user friendly tools and features to design and congure devices and enclosures following an electrical component mounting logic. The Power Design package also includes a tool that allows the user to congure the new EntelliGuard G Power Circuit Breaker, its catalogue code and denes the subcomponents of which it is built.
(1)

Also available in IEC 60364 version.

14

EntelliGuard G
Power Circuit Breakers A.2 A.4 A.5 A.6 A.8 A.10 A.11 A.12 EntelliGuard G: How to order in 8 steps Basic breakers executed in a xed mounting pattern Isolators or Non Automatic Breakers in a xed mounting pattern Termination sets for Breakers & Isolators in xed mounting pattern Basic breakers: Draw out Breakers; Moving Portion only Isolators or Non Automatic Breakers: Draw out Patterns; Moving Portion only Cassettes for use with Breakers & Isolators in Draw out Pattern; Factory mounted Trip Units for EntelliGuard G Power Circuit Breakers; Factory mounted

Internal Accessories A.17 A.20 Factory mounted Field mountable

A.23 A.24

Installation Accessories Sensors for Trip Units

The breaker Order Codes

Intro A B C D E F X

A.25 A.26 A.28

Cassettes for use with Breakers & Isolators in Draw out Pattern; Field mountable Field Mounted (spare) Trip Units For EntelliGuard G Air Circuit Breakers Spare Parts for EntelliGuard G Power Circuit Breakers

Electronic Trip Units Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

Global Catalogue number structure A.30 A.33 Breaker Cassette

Valid Catalogue number combinations A.34 A.35 A.36 A.38 Factory mounted: Available standard Breaker & Cassette types Factory mounted: Available standard Breaker, Cassette and Trip Unit types Factory mounted: Available standard Isolator & Cassette types Accessories; Factory and Field mountable

A.1

EntelliGuard G

How to order
Step 1 Step 2 Step 3 Step 4
Choose Current rating Choose required Interruption Rating Dene if a Breaker or Isolator is needed Proceed to establish the rst 5 digits of the Catalogue Number as indicated here Select the required product A - Breaker or Isolator In Fixed Pattern B - Breaker or Isolator As Draw out, Moving Portion C - Cassette for Draw out Breaker or Isolator

Order codes

In

} } }
Icu = Ics
440V AC 400A 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 50kA 65kA 85kA 85kA 100kA 65kA 85kA 100kA 65kA 85kA 100kA 100kA 150kA 65kA 85kA 100kA 100kA 150kA 100kA 150kA 100kA 150kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 50kA 65kA 65kA 85kA 85kA 65kA 85kA 85kA 65kA 85kA 85kA 100kA 100kA 65kA 85kA 85kA 100kA 100kA 100kA 100kA 100kA 100kA 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 2 2 2 2 2 2 3 3 2 2 2 3 3 3 3 3 3

Icw

Envelope

Standard
Breaker GG04S GG04N GG04H GG04E GG04M GG07S GG07N GG07H GG07E GG07M GG08S GG08N GG08H GG08E GG08M GG10S GG10N GG10H GG10E GG10M GG13S GG13N GG13H GG13E GG13M GG16S GG16N GG16H GG16E GG16M GG20S GG20N GG20H GG20E GG20M GG25N GG25H GG25M GG32N GG32H GG32M GG32G GG32L GG40N GG40H GG40M GG40G GG40L GG50M GG50L GG64M GG64L Isolator* GJ04S GW04N GW04M GJ07S GW07N GW07M GJ08S GW08N GW08M GJ10S GW10N GW10M GJ13S GW13N GW13M GJ16S GW16N GJ16M GJ20S GW20N GW20M GJ25N GW25H GJ32N GW32M GJ32L GJ40N GW40M GJ40L GJ50L GJ64L

100% Rated
Breaker Isolator*

Denes the 6th digit In catalogue number

630A

Intro
800A

4 = Breaker / Isolator In Fixed Pattern 3 pole 6 = Breaker / Isolator In Fixed Pattern 4 pole*

A
1000A

B
1250A

C
1600A

1 = Breaker / Isolator Moving Portion Only 3 pole 3 = Breaker / Isolator Moving Portion Only 4 pole**

D
2000A

E
2500A

F X

3200A

GH32N GH32H GH32M GH40N GH40H GH40M

GK32N GZ32H

2 = Cassette for Draw out Pattern = Fixed Portion Only 3 pole 5 = Cassette for Draw out Pattern = Fixed Portion Only 4 pole**

4000A

GK40N GZ40H

5000A 6400A

* On Isolators Icu and Ics values do not apply

** 4 pole Neutral Left

Examples Breaker 4p 1600A- Draw-out Portion only- Icu=85kA, Ics=Icw=65kA:

GG16H3
Breaker 3p 3200A Fixed Pattern -Horizontal Rear Connections - Icu=Ics=Icw=65kA:

GG32N4

A.2

EntelliGuard G

in 8 steps
Step 5 Step 6 Step 7 Step 8
Finalize the basic Catalogue number see catalogue pages: A.4-A.5 - Fixed Pattern A.8-A.10 - Draw out Portion A.6 - Connections xed pattern A.11 - Cassettes, draw out Basic Catalogue number is a Manually operated device If a Motor Operated device is requested? Please order Motor and closing coils as Indicated here *** If Universal internal Accessories*** are needed? Options UVR or SHT release (s) Network Interlocks Auxiliary contacts Alarm & signal contacts Full Catalogue number denes: A Breaker without Trip Unit For all Breakers ADD Trip Unit

How to order in 8 steps

completing the basic catalogue number


No addition Indicates Breaker / Isolator In Fixed Pattern has set of 3NO/3NC aux. Contacts included Breaker in xed Pattern Are equipped with Rear Connection (Horizontal) Other options include Rear (Vertical) and Front (Flat) See page A 6 to order Field mountable Adaptation Kits See pages A.4, 5 & 6

Add Catalogue number (s)

Add Catalogue number (s)

Add Catalogue number (s)

If chosen device is a Breaker or Isolator Envelope 1 See page A.17 Order a Motor Type1 and 1 Closing Coil or 1 Command closing coil Based on voltage Requirements and specications If chosen device is a Breaker or Isolator Envelope 2 or 3 See page A.17 Order a Motor type 2 and 1 Closing Coil or 1 Command closing coil Based on voltage Requirements and specications

If chosen device is a Breaker or Isolator See page A.17 To add up to 3 SHT or UVR Releases Or 1 Network Interlock Coils and 1 SHT or UVR Release

If chosen device is a Breaker See pages A.12 to A.16 Choose and Add a Trip Unit out of the the four basic types and 39 different options. Offering An Extremely Large setting range covering Overload, Delayed and Instantaneous Short-circuit Protection Groundfault Protection in Single or Dual mode suited for applications as UEF, REF & SEF or combinations thereof Complete and sophisticated Network measurement options, Including Wave Form Capture Multiple relaying options as Zone Selective Interlock, Undervoltage, Overvoltage, Reverse Power etc.

Intro A B C D E F

No addition Indicates Breaker / Isolator Moving Portion Only has set of 3NO/3NC aux. Contacts included See pages A.7, 8 & 9

If chosen device is a Breaker or Isolator See page A.17 To extend on the installed 3 NO + 3NC contacts Maximum of 8 possible If chosen device is a Breaker or Isolator See page A.17 To add Bell Alarm and/or Coils signalling contacts If chosen device is a Cassette See page A.17 & A.18 To Add Position indication Contacts in Cassette Or provisions for key interlocks

U = Cassette with Universal 'T stabs' suited for use as Horizontal or Vertical rear connections Safety Shutters Supplied with Cassette *** V = Cassette with Vertical Rear Connections Safety Shutters Supplied with Cassette *** F = Cassette with Front Flat connections Safety Shutters Supplied with Cassette *** See page A.11

- Or A 2nd ordering method can be used in which the fully congured breaker or cassette is dened in one character string. This string comprises 19 digits when used for the breaker and 12 for when used for the cassette. This global ordering code is referred to within GE as the: Catalogue Number It is used on all relevant ordering documents and printed on each EntelliGuard G breaker front facia. An explanation of this code and its use can be found on page A.30 of this catalogue. When ordering with the method indicated here our CRC department will dene and conrm the mentioned individual Catalogue Number.
*** Devices ordered here are supplied factory tted Remark: For Field Mountable Accessories see page A.21 to A.25

A.3

EntelliGuard G
Basic breakers executed in a xed mounting pattern
With Horizontal Rear Connection (For other options, please refer to page A.6)(1) With Aux.contact block equipped with 3 NO and 3 NC contacts Basic Breaker MUST be equipped with a Trip Unit (For options, please refer to page A.12 to A.16) For 1000V applications (M and L types) phase seperators are required (see page A.23)

Fixed Mounting Pattern


3 pole Rating (A) Cat. No. GG04S4 GG07S4 GG08S4 GG10S4 GG13S4 GG16S4 GG20S4 GG04N4 GG07N4 GG08N4 GG10N4 GG13N4 GG16N4 GG20N4 GG25N4 GG32N4 GG40N4 GG04H4 GG07H4 GG08H4 GG10H4 GG13H4 GG16H4 GG20H4 GG04E4 GG07E4 GG08E4 GG10E4 GG13E4 GG16E4 GG20E4 GG25H4 GG32H4 GG40H4 GG04M4 GG07M4 GG08M4 GG10M4 GG13M4 GG16M4 GG20M4 GG25M4 GG32M4 GG40M4 GG32G4 GG40G4 GG50M4 GG44M4 GG32L4 GG40L4 GG50L4 GG64L4 Ref. No. 407019 407048 407078 407108 407138 407168 407208 407015 407044 407074 407104 407134 407164 407204 407240 407266 407292 407007 407036 407066 407096 407126 407156 407196 407003 407032 407062 407092 407122 407152 407192 407232 407244 407280 407011 407040 407070 407100 407130 407160 407200 407236 407262 407288 407252 407270 407306 407326 407254 407284 407302 407322 Cat. No. GG04S6 GG07S6 GG08S6 GG10S6 GG13S6 GG16S6 GG20S6 GG04N6 GG07N6 GG08N6 GG10N6 GG13N6 GG16N6 GG20N6 GG25N6 GG32N6 GG40N6 GG04H6 GG07H6 GG08H6 GG10H6 GG13H6 GG16H6 GG20H6 GG04E6 GG07E6 GG08E6 GG10E6 GG13E6 GG16E6 GG20E6 GG25H6 GG32H6 GG40H6 GG04M6 GG07M6 GG08M6 GG10M6 GG13M6 GG16M6 GG20M6 GG25M6 GG32M6 GG40M6 GG32G6 GG40G6 GG50M6 GG64M6 GG32L6 GG40L6 GG50L6 GG64L6 4 pole* Ref. No. 407020 407049 407079 407109 407139 407169 407209 407016 407045 407075 407105 407135 407165 407205 407241 407267 407293 407008 407037 407067 407097 407127 407157 407197 407004 407033 407063 407093 407123 407153 407193 407233 407245 407281 407012 407041 407071 407101 407131 407161 407201 407237 407263 407289 407253 407271 407307 407327 407255 407285 407303 407323

Order codes

S type
Icu = Ics = Icw 50kA

400 630 800 1000 1250 1600 2000 400 630 800 1000 1250 1600 2000 2500 3200 4000 400 630 800 1000 1250 1600 2000 400 630 800 1000 1250 1600 2000 2500 3200 4000(1) 400 630 800 1000 1250 1600 2000 2500 3200 4000(1) 3200 4000 5000 6400 3200 4000 5000 6400

N type

Intro A

Icu = Ics = lcw 65kA

H type

B C

Icu = Ics = 85kA lcw = 65kA

E-H type

D E F X

Icu = Ics = Icw 85kA

M type
Icu = Ics = 100kA Icw = 85kA

G-M type
Icu = Ics = Icw 100kA

L type
Icu = Ics = 150kA Icw = 100kA

* 4th pole on Left, Trip Unit Field Congurable at 0, 50 or 100% of phase rating (1) Rear Vertical Connection for Indicated 4000A types

A.4

EntelliGuard G
Isolators or Non Automatic Breakers executed in a xed mounting pattern
- With Horizontal Rear Connection (For other options, please refer to page A.6)(1) - With Aux. contact block equipped with 3 NO and 3 NC contacts - For 1000V applications (M and L types) phase seperators are required (see page A.23)

Fixed Mounting Pattern

Fixed Mounting Pattern


3 pole Rating (A) Cat. No. GJ04S4 GJ07S4 GJ08S4 GJ10S4 GJ13S4 GJ16S4 GJ20S4 GW04N4 GW07N4 GW08N4 GW10N4 GW13N4 GW16N4 GW20N4 GJ25N4 GJ32N4 GJ40N4 GW04M4 GW07M4 GW08M4 GW10M4 GW13M4 GW16M4 GW20M4 GW25M4 GW32M4 GW40M4 GJ32L4 GJ40L4 GJ50L4 GJ64L4 Ref. No. 407380 407400 407420 407440 407460 407480 407500 407376 407396 407416 407436 407456 407476 407496 407520 407539 407560 408350 408352 408354 408356 408358 408360 408362 408364 408366 408368 407535 407556 407567 407577 Cat. No. GJ04S6 GJ07S6 GJ08S6 GJ10S6 GJ13S6 GJ16S6 GJ20S6 GW04N6 GW07N6 GW08N6 GW10N6 GW13N6 GW16N6 GW20N6 GJ25N6 GJ32N6 GJ40N6 GW04M6 GW07M6 GW08M6 GW10M6 GW13M6 GW16M6 GW20M6 GW25M6 GW32M6 GW40M6 GJ32L6 GJ40L6 GJ50L6 GJ64L6 4 pole* Ref. No. 407381 407401 407421 407441 407461 407481 407501 407377 407397 407417 407437 407457 407477 407497 407521 407540 407561 408351 408353 408355 408357 408359 408361 408363 408365 408367 408369 407536 407557 407568 407578

S type
Non Automatic Icw 50kA

400 630 800 1000 1250 1600 2000 400 630 800 1000 1250 1600 2000 2500 3200 4000 (1) 400 630 800 1000 1250 1600 2000 2500 3200 4000(1) 3200 4000 5000 6400

N type
Non Automatic Icw 65kA

Intro A B C D E

M type
Non Automatic Icw 85kA

L type
Non Automatic Icw 100kA

* 4th pole on Left (1) Rear Vertical Connection for Indicated 4000A types

F X

A.5

EntelliGuard G
Termination sets for Breakers & Isolators in Fixed pattern
To modify Standard connection (Horizontal Rear) to: Vertical Rear Front at connection Sets containing terminals and hardware for the line & load side of the breaker

Termination sets for Breakers & Isolators in xed Pattern


Vertical Rear Connections Suited for use with EntelliGuard G types Rating (A) Cat. No. G20H4RVI G32M4RVI G40M4RVI G64L4RVI Terminations for Envelope 1 400 - 2000A GG, GJ & GW type S, N & H Terminations for Envelope 2 400 - 3200A GG, GJ & GW type E, N, H & M 4000A(2) GG, GJ & GW type N, H & M Terminations for Envelope 3 3200 - 6400A GG & GJ type G, M & L 3 pole Ref. No. 408064 408070 408072 408073 Cat. No. G20H6RVI G32M6RVI G40M6RVI G64L6RVI 4 pole Ref. No. 408065 408071 408074 408075

Order codes

Front access Connections

Intro A B C D E F X
Wall mounting Brackets **

Terminations for Envelope 1 400 - 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H Terminations for Envelope 2 400 - 3200A GG, GJ & GW type E, N, H & M 4000A GG, GJ & GW type N, H & M

G16H4FFI G20H4FFI G32M4FFI G40M4FFI

408060 408061 408066 408067

G16H6FFI G20H6FFI G32M6FFI G40M6FFI

408062 408063 408068 408069

Wall Mounting Brackets for Env. 1 & 2

GFMTG

408085

GFMTG

408085

** Recommended for use with Front access Connections (2) For the 4000A types are supplied with the standard xed breaker

A.6

EntelliGuard G
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Intro A B C D E F X

A.7

Terminations; Fixed Pattern

EntelliGuard G
Basic breakers: Draw out Breakers; Moving Portion only
- With Aux. contact block equipped with 3 NO and 3 NC contacts - Basic Breaker MUST be equipped with a Trip Unit (please refer to page A.12 to A.16 for options) - A cassette is needed, please refer to page A.11 for options - For 1000V applications (M and L types) phase seperators are required (see page A.23)

Draw out Pattern; moving portion only


3 pole Rating (A) Cat. No. GG04S1 GG07S1 GG08S1 GG10S1 GG13S1 GG16S1 GG20S1 GG04N1 GG07N1 GG08N1 GG10N1 GG13N1 GG16N1 GG20N1 GG25N1 GG32N1 GG40N1 GG04H1 GG07H1 GG08H1 GG10H1 GG13H1 GG16H1 GG20H1 GG04E1 GG07E1 GG08E1 GG10E1 GG13E1 GG16E1 GG20E1 GG25H1 GG32H1 GG40H1 GG04M1 GG07M1 GG08M1 GG10M1 GG13M1 GG16M1 GG20M1 GG25M1 GG32M1 GG40M1 GG32G1 GG40G1 GG50M1 GG64M1 GG32L1 GG40L1 GG50L1 GG64L1 Ref. No. 407017 407046 407076 407106 407136 407166 407206 407013 407042 407072 407102 407132 407162 407202 407238 407264 407290 407005 407034 407064 407094 407124 407154 407194 407001 407030 407060 407090 407120 407150 407190 407230 407242 407278 407009 407038 407068 407098 407128 407158 407198 407234 407260 407286 407250 407268 407304 407324 407248 407282 407300 407320 Cat. No. GG04S3 GG07S3 GG08S3 GG10S3 GG13S3 GG16S3 GG20S3 GG04N3 GG07N3 GG08N3 GG10N3 GG13N3 GG16N3 GG20N3 GG25N3 GG32N3 GG40N3 GG04H3 GG07H3 GG08H3 GG10H3 GG13H3 GG16H3 GG20H3 GG04E3 GG07E3 GG08E3 GG10E3 GG13E3 GG16E3 GG20E3 GG25H3 GG32H3 GG40H3 GG04M3 GG07M3 GG08M3 GG10M3 GG13M3 GG16M3 GG20M3 GG25M3 GGM3M3 GG40M3 GG32G3 GG40G3 GG50M3 GG64M3 GG32L3 GG40L3 GG50L3 GG64L3 4 pole* Ref. No. 407018 407047 407077 407107 407137 407167 407207 407014 407043 407073 407103 407133 407163 407203 407239 407265 407291 407006 407035 407065 407095 407125 407155 407195 407002 407031 407061 407091 407121 407151 407191 407231 407273 407279 407010 407039 407069 407099 407129 407159 407199 407235 407261 407287 407251 407269 407305 407325 407249 407283 407301 407321

S type

Order codes

Icu = Ics = Icw 50kA

400 630 800 1000 1250 1600 2000 400 630 800 1000 1250 1600 2000 2500 3200 4000 400 630 800 1000 1250 1600 2000 400 630 800 1000 1250 1600 2000 2500 3200 4000 400 630 800 1000 1250 1600 2000 2500 3200 4000 3200 4000 5000 6400 3200 4000 5000 6400

N type

Intro A

Icu = Ics = Icw 65kA

H type

B C

Icu = Ics = 85kA Icw = 65kA

E-H type

D E F X

Icu = Ics = Icw 85kA

M type
Icu = Ics = 100kA Icw = 85kA

G-M type
Icu = Ics = Icw 100kA

L type
Icu = Ics = 150kA Icw = 100kA

* 4th pole on Left, Trip Unit Field Congurable at 0, 50 or 100% of phase rating

A.8

EntelliGuard G
Draw out Breakers with vertical dual clusters; Moving Portion only
Draw out Breaker with no or very limited de-rating when used enclosed With Aux. contact block equipped with 3 NO and 3 NC contacts Basic Breaker MUST be equipped with a Trip Unit (please refer to page A.12 to A.16 for options) A cassette with vertical clusters is needed, please refer to page A.11 for options

Draw out Pattern; moving portion

Draw out Pattern, vertical clusters; moving portion only


3 pole Rating (A) Cat. No. GH32N1 GH40N1 Ref. No. 407350 407356 Cat. No. GH32N3 GH40N3 4 pole* Ref. No. 407351 407357

N type
Icu = Ics = Icw 65kA

3200 4000

H type
Icu = Ics = Icw 85kA

3200 4000 3200 4000

GH32H1 GH40H1 GH32M1 GH40M1

407346 407352 407348 407354

GH32H3 GH40H3 GH32M3 GH40M3

407347 407353 407349 407355

M type
Icu = Ics = 100kA Icw = 85kA

* 4th pole on Left, Trip Unit Congurable at 0, 50 or 100% of phase rating

Intro A B C D E F X

A.9

EntelliGuard G
Isolators or Non Automatic Breakers: Draw out Patterns; Moving Portion only
- With Aux. contact block equipped with 3 NO and 3 NC contacts - A cassette is needed, please refer to page A.11 for options - For 1000V applications (M and L types) phase seperators are required (see page A.23)

Draw out Pattern; moving portion only


3 pole Rating (A) Cat. No. GJ04S1 GJ07S1 GJ08S1 GJ10S1 GJ13S1 GJ16S1 GJ20S1 GW04N1 GW07N1 GW08N1 GW10N1 GW13N1 GW16N1 GW20N1 GJ25N1 GJ32N1 GJ40N1 GW04M1 GW07M1 GW08M1 GW10M1 GW13M1 GW16M1 GW20M1 GW25M1 GW32M1 GW40M1 GJ32L1 GJ40L1 GJ50L1 GJ64L1 Ref. No. 407378 407398 407418 407438 407458 407478 407498 407374 407394 407414 407434 407454 407474 407494 407518 407537 407558 408400 408402 408404 408406 408408 408410 408412 408414 408416 408418 407533 407554 407565 407575 Cat. No. GJ04S3 GJ07S3 GJ08S3 GJ10S3 GJ13S3 GJ16S3 GJ20S3 GW04N3 GW07N3 GW08N3 GW10N3 GW13N3 GW16N3 GW20N3 GJ25N3 GJ32N3 GJ40N3 GW04M3 GW07M3 GW08M3 GW10M3 GW13M3 GW16M3 GW20M3 GW25M3 GW32M3 GW40M3 GJ32L3 GJ40L3 GJ50L3 GJ64L3 4 pole* Ref. No. 407379 407399 407419 407439 407459 407479 407499 407375 407395 407415 407435 407455 407475 407495 407519 407538 407559 408401 408403 408405 408407 408409 408411 408413 408415 408417 408419 407534 407555 407566 407576

S type

Order codes

Non Automatic Icw 50kA

400 630 800 1000 1250 1600 2000 400 630 800 1000 1250 1600 2000 2500 3200 4000 400 630 800 1000 1250 1600 2000 2500 3200 4000 3200 4000 5000 6400

N type

Intro A B C D E F X

Non Automatic Icw 65kA

M type
Non Automatic Icw 85kA

L type
Non Automatic Icw 100kA

Power Circuit Breakers types with Vertical Cluster system


Isolators or Non Automatic Breakers with dual vertical clusters; Moving Portion only - Draw out Patterns with no or very limited de-rating when used enclosed - With Aux. contact block equipped with 3 NO and 3 NC contacts - A cassette with vertical clusters is needed, please refer to page A.11 for options

Draw out Pattern, vertical clusters; moving portion only


3 pole 4 pole* Ref. No. 407591 407595 407589 407593 Cat. No. GK32N3 GK40N3 GZ32H3 GZ40H3 Ref. No. 407592 407596 407590 407594

N type
Non Automatic Icw 65kA

Rating (A) 3200 4000 3200 4000

Cat. No. GK32N1 GK40N1 GZ32H1 GZ40H1

H type
Non Automatic Icw 85kA * 4th pole on Left

A.10

EntelliGuard G
Cassettes for use with Breakers & Isolators in Draw out Pattern; Factory mounted
- References apply for Cassettes supplied in one Packaging with Breakers or Isolators (For Separate Cassettes see page A.25) - With Connection modes as indicated in left column - Each cassette is supplied with safety shutters

Draw out Pattern: cassettes

Cassettes for Draw out Pattern; xed portion only


Universal Rear Connections 3 pole Rating (A) Suited for use with EntelliGuard G -G types Cat. No. GG13H2UM GG16H2UM GG20H2UM GG20M2UM GG25M2UM GG32M2UM GG40M2UM Ref. No. 407692 408202 408212 408224 408236 408247 408259 Cat. No. GG13H5UM GG16H5UM GG20H5UM GG20M5UM GG25M5UM GG32M5UM GG40M5UM 4 pole Ref. No. 407695 408205 408215 408227 408239 408251 408263

Cassette for envelope 1 400 - 1250A GG, GJ & GW type S, N & H 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H Cassette for envelope 2 400 - 2000A GG, GJ & GW type N, E & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M(1) 4000A GG, GJ & GW type N, H & M(1) Remark: Each cassette is supplied with connection pads that can be rotated and used for Vertical or Horizontal connections. Cassette for envelope 3 (2) 3200 - 6400A** GG & GJ type G, M & L

Intro
GG64L2UM 408281 GG64L5UM 408283

A
Vertical rear Connections Cassette with dual vertical clusters and connection pads for limited derating envelope 2 3200A GH, GK, GJ & GZ type N.H & M 4000A GH, GK, GJ & GZ type N.H & M(1) GH32M2VM GH40M2VM 408292 408294 GH32M5VM GH40M5VM 408293 408295

B C

Front access Connections Cassette for envelope 1 400 - 1250A GG, GJ & GW type S, N & H 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H GG13H2FM GG16H2FM GG20H2FM 407690 408200 408210 GG13H5FM GG16H5FM GG20H5FM 407693 408203 408213

D E

Cassette for envelope 2 400 - 2000A GG, GJ & GW type E, N, H & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M 4000A GG, GJ & GW type N, H & M

GG20M2FM GG25M2FM GG32M2FM GG40M2FM

408222 408234 408245 408257

GG20M5FM GG25M5FM GG32M5FM GG40M5FM

408225 408237 408249 408261

F X

* 4th pole on Left (1) Cassettes for envelope 2 are limited to a current of 3200A when connected in horizontal mode. Connected in vertical mode a 4000A rating is achieved (2) The Cassette for envelope 3 is limited to a current of 5000A when connected in horizontal mode. Connected in vertical mode it has a rating of 6400A. This cassette type is NOT depicted here

A.11

EntelliGuard G
Trip Units - Factory mounted

GT- E
LT-C

Basic functionality

Designation GT-E Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB GT-Rating Plug

Extended functionality None

Cat. No. GTG00K1-SF

Ref. No. 408800

LTDB

Required for all types

GTPUNI

408860

ST

I t on STDB

Order codes

LT-C

LTDB

GT-E Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB GF IT ON or OFF GFDB
I2 t on STDB

None

GTG00K2-SF

408801

ST

Intro A B C D
GT- S

GT-Rating Plug

Required for all types

GTPUNI

408860

GF I2 t on GFDB

L T-C

LTDB

GT-S Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB I GT-Rating Plug
I2 t on STDB I

None

GTG00K9-SF

408803

ST

Required for all types

GTPUNI

408860

LT-C

E F X
LT-C GF

LTDB

GT-S Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB GF IT ON or OFF GFDB I
I2 t on STDB

None + Modbus Communication

GTG00K3-SF GTG00K3-2SF

408805 408807

ST

GT-Rating Plug
I

Required for all types

GTPUNI

408860

I t on GFDB

LTDB

ST GF I2 t on GFDB

I2 t on STDB
l ext.

GT-S Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB GF IT ON or OFF GFDB I ext. GT-Rating Plug

None + Modbus Communication

GTG00K4-SF GTG00K4-2SF

408806 408808

Required for all types

GTPUNI

408860

A.12

EntelliGuard G
Trip Units - Factory mounted

GT- N
LT-C

Basic functionality

Designation GT-N Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB I RELT

Extended functionality Measurement unit (1) RELT Instantaneous

Cat. No. GTG00K9-4SF

Ref. No. 408813

LTDB

Electronic Trip Units

ST

I2 t on STDB I

GT-Rating Plug

Required for all types

GTPUNI

408860

Extended functionality

RELT

Basic functionality
LT-C

LTDB

ST GF I2 t on GFDB

I2 t on STDB I

GT-N Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB GF IT ON or OFF GFDB I RELT GT-Rating Plug

Measurement unit (1) RELT Instantaneous + Modbus Communication + Zone Selective Interlock on I, ST & GF functions

GTG00K3-4SF GTG00K3T6SF

408815 408817

Intro A

Required for all types

GTPUNI

408860

B C D

Extended functionality

RELT

Basic functionality
LT-C

LTDB

I t on Basic functionality GF I2 t on GFDB STDB

ST

GT-N Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST IT ON or OFF STDB GF IT ON or OFF GFDB I ext. RELT GT-Rating Plug

Measurement unit (1) RELT Instantaneous + Modbus Communication + Zone Selective Interlock on I, ST & GF functions

GTG00K4-4SF GTG00K4T6SF

408816 408818

E F

Required for all types

GTPUNI

408860

I ext.

Extended functionality Extended functionality


RELT

(1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22

A.13

EntelliGuard G
Trip Units - Factory mounted

GT- H
LT-C

Basic functionality

Designation GT-H Trip Unit with: LT-C 0.2- 1 x In =Ir -ORLT-F 0.2- 1 x in =Ir LTDB ST I2T ON or OFF STDB I RELT

Extended functionality

Cat. No.

Ref. No. 408823

LTDB

LT Band shape Choice (LTC or LTF) GTG00N9-5SF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous LT Band shape Choice (LTC or LTF) GTG00N9-8SF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication LT Band shape Choice (LTC or LTF) GTG00N9-9SF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication

408863

ST

I2 t on STDB I

Order codes

408865

Extended functionality
LT-F

GT-Rating Plug
LTDB

Required for all types

GTPUNI

408860

Intro A B
ST LT-C

RELTi

Basic functionality GT-H Trip Unit with: LT-C 0.2- 1 x In =Ir -ORLT-F 0.2- 1 x in =Ir LTDB ST I2T ON or OFF STDB GF sum. I2T ON or OFF -AND/ORGF CT I2T ON or OFF GFDB I RELT LT Band shape Choice (LTC or LTF) GTG00N5-5SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous LT Band shape Choice (LTC or LTF) GTG00N5-8SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication LT Band shape Choice (LTC or LTF) GTG00N5-9SF Dual GF Protection (Res./Sum or CT) (1) Measurement Unit Data aquisition & Relay functionality RELT Instantaneous Probus Communication LT Band shape Choice (LTC or LTF) GTG00N5T5SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous LT Band shape Choice (LTC or LTF) GTG00N5T8SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication GTG00N5T9SF LT Band shape Choice (LTC or LTF) Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication GT-Rating Plug Required for all types GTPUNI 408825

LTDB

408833

I2 t on STDB

GF

C D E F X
LT-F

I2 t on GFDB

408841

Extended functionality

LTDB

408829

RELTi

408837

408845

408860

(1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22

A.14

EntelliGuard G
Trip Units - Factory mounted

GT- H
LT-C

Basic functionality

Designation GT-H Trip Unit with: LT-C 0.2- 1 x In =Ir -ORLT-F 0.2- 1 x In =Ir LTDB ST I2T ON or OFF STDB GF sum. I2T ON or OFF -AND/ORGF CT I2T ON or OFF GFDB I ext. RELT

Extended functionality

Cat. No.

Ref. No. 408827

LTDB

LT Band shape Choice (LTC or LTF) GTG00N7-5SF Dual GF Protection (Res./Sum or CT) (1) Measurement Unit Data aquisition & Relay functionality RELT Instantaneous LT Band shape Choice (LTC or LTF) GTG00N7-8SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication LT Band shape Choice (LTC or LTF) GTG00N7-9SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication LT Band shape Choice (LTC or LTF) GTG00N7T5SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous LT Band shape Choice (LTC or LTF) GTG00N7T8SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication GTG00N7T9SF LT Band shape Choice (LTC or LTF) Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication

Electronic Trip Units

408835

ST

I2 t on STDB

GF I t on GFDB
2

l ext.

408843

Extended functionality
LT-F

LTDB

408831

RELTi

408839

Intro A

408847

B C

GT-Rating Plug

Required for all types

GTPUNI

408860

(1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22

D E F X

A.15

EntelliGuard G
Trip Units - Factory mounted

GT- H
LT-C

Basic functionality

Designation GT-H Trip Unit with: LT-C 0.2- 1 x In =Ir -ORLT-F 0.2- 1 x In =Ir LTDB ST I2T ON or OFF STDB GFA(2) sum. I2T ON or OFF -AND/ORGFA(2) sum. I2T ON or OFF GFDB I or I ext. RELT

Extended functionality

Cat. No.

Ref. No. 408826

LTDB

LT Band shape Choice (LTC or LTF) GTG00N6-5SF Dual GF Protection (Res./Sum or CT) (1) Measurement Unit Data aquisition & Relay functionality RELT Instantaneous With standard Instaneous Idem with Extended Instananeous GTG00N8-5SF LT Band shape Choice (LTC or LTF) GTG00N6-8SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8-8SF LT Band shape Choice (LTC or LTF) GTG00N6-9SF Dual GF Protection (Res./Sum or CT) Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8-9SF

408828 408834

ST

I2 t on STDB

GF I t on
2

l ext.

Order codes

GFDB

Extended functionality
LT-F

408836 408842

LTDB

408844 408830

Intro A B C D E F X

RELTi

LT Band shape Choice (LTC or LTF) GTG00N6T5SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous With standard Instaneous Idem with Extended Instananeous GTG00N8T5SF LT Band shape Choice (LTC or LTF) GTG00N6T8SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T8SF LT Band shape Choice (LTC or LTF) GTG00N6T9SF Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T9SF GT-Rating Plug Required for all types GTPUNI

408832 408838

408840 408846

408848 408860

(1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 (2) Does NOT trip the associated EntelliGuard G Breaker, BUT produces an Alarm signal

A.16

EntelliGuard G
Internal Accessories; Factory mounted
Internal Accessories - Factory mounted
For eld mounted variants see page A.20 & A.21

Motor Operators and Closing Coils(4) Motor Operator Type 1 Cat. No. 24-30V DC 48V DC 60V DC 110-130V DC 250V DC 48V AC 110-130V AC 220-240V AC 380-400V AC 440V AC GM01024D GM01048D GM01060D GM01110D GM01250D GM01048A GM01120A GM01240A GM01400A GM01440A Ref. No. 407700 407702 407704 407706 407708 407710 407712 407714 407716 407718 Motor Operator Type 2 & 3 Cat. No. GM02024D GM02048D GM02060D GM02110D GM02250D GM02048A GM02120A GM02240A GM02400A GM02440A Ref. No. 407725 407727 407729 407731 407733 407735 407737 407739 407741 407743 Comm. Closing Coil(1) GCCC024D GCCC048 GCCC060D GCCC120 GCCC240 GCCC277 GCCC400A GCCC440A Shunt GSTR024D GSTR048 GSTR060D GSTR120 GSTR240 GSTR277 GSTR400A GSTR440A 407770 407772 407774 407776 407778 407780 407782 407784 407836 407838 407840 407842 407844 407849 407852 407853 Cat. No. Ref. No.

Closing Coil 2V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC Releases Undervoltage 24V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC Auxiliary Contacts Power Rated 3NO & 3NC Power Rated 8NO & 8NC Power Rated 3NO & 3NC + signal rated 2NO & 2NC Power Rated 4NO & 4NC + signal rated 4NO & 4NC Bell Alarm Contacts 1 Changeover GBAT1 407891 GUVT024D GUVT048 GUVT060D GUVT120 GUVT240 GUVT277 GUVT400A GUVT440A 407795 407797 407799 407801 407803 407805 407807 407809 GCCN024D GCCN048 GCCN060D GCCN120 GCCN240 GCCN277 GCCN400A GCCN440A 407861 407863 407865 407867 407869 407870 407877 407878

Network Interlock(3)

Intro A B C D E

GNTK120 GNTK240

407753 407754

Delivered as standard option in all EntelliGuard G breakers & Isolators GAUX6 407887 GAUX5 407886 GAUX8 407888

Indication Contacts Power rated wired through sec. Discon. CC/CCC/UVT/STR Release indicator 1NO Breaker Ready to Close indic.(2) 1NO GCSP1 GRTC1 407895 407897 GRTC2 407899 Signal rated wired through sec. Discon. Signal rated wired Trip Unit (comm.) GCSP2 GRTC3 407896 407894

F X

Position Indication Contacts Cassette Power rated on Cassette 1 Changeover per position 2 Changeovers per position GCPS1 GCPS2 407922 407923

(1) Command closing coil allows breaker closure by means of a push-button located on the breaker front facia that is included in the kit Optionally the Command close coil can be accessed via the Trip Unit (communication bus) (2) Not available as eld mountable accessory (3) Please contact us for availability (4) Motor Spring charged indication contact supplied with Motor Operator

A.17

EntelliGuard G
Internal Accessories - Factory mounted
For eld mounted variants see page A.20 & A.21

Locking Mechanisms (5) Ronis Cat. No. Mounted on Breaker The Ronis and Profalux devices allow 1 to 4 Locks to be placed. The Castell device 1 Mounted on Cassette. (2 devices for 2 locks are possible) Operation Front Fascia of Breaker Counter; number of Operations GBRON Ref. No. 407971 Castell Cat. No. GBCAS Ref. No. 407970 Profalux Cat. No. GBPRO Ref. No. 407978

GCRON

407976

GCPRO

407980

Order codes

GMCN

408035

Mounted Interlocks for Cables(6) Interlock Scheme Type A Brk. 1 OFF ON OFF OFF ON OFF OFF OFF ON OFF OFF ON OFF ON OFF ON OFF ON OFF Brk. 2 OFF OFF ON OFF OFF ON OFF OFF OFF OFF ON ON ON OFF OFF OFF OFF OFF ON Brk. 3 Fixed Pattern Cat. No. Ref. No. For Each Breaker GI2FAD 407900 OFF OFF OFF ON OFF OFF ON OFF OFF ON ON OFF OFF ON ON OFF For Each Breaker GI3FB 407902 Draw out Cat. No. Ref. No. For Each Breaker GI2WAD 407901 For Each Breaker GI3WB 407903

Intro A B

For Each Breaker GI3FC 407904

For Each Breaker GI3WC 407905

For Brk.1 & 3 GI2FAD 407900 For Brk. 2 GI3FDT 407906

For Brk.1 & 3 GI2WAD 407901 For Brk. 2 GI3WDT 407907

C D

(5) For the separately available locks see page A.19, Kirk Lock version available on request (6) These kits are only available FACTORY MOUNTED: On the a draw out breaker or isolator the mechanisms are mounted on the breaker cassette need to be ordered in combination with a breaker and mounted Cassette. For the associated, separately available cables see page A.22

Internal Accessories - Factory mounted

E F X

Maximum amount of installable internal accessories - See page A.21.

A.18

EntelliGuard G
Internal Accessories; Factory mounted
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Intro A B C D E F X

A.19

EntelliGuard G
Internal Accessories - Field mountable
For factory mounted variants see page A.17 & A.18

Motor Operators and Closing Coils Motor Operator Envelope 1 Motor Operator Envelope 2 & 3 Cat. No. 24-30V DC 48V DC 60V DC 110-130V DC 250V DC 48V AC 110-130V AC 220-240V AC 380-400V AC 440V AC GM01024DR GM01048DR GM01060DR GM01110DR GM01250DR GM01048AR GM01120AR GM01240AR GM01400AR GM01440AR Ref. No. 407701 407703 407705 407707 407709 407711 407713 407715 407717 407719 Cat. No. GM02024DR GM02048DR GM02060DR GM02110DR GM02250DR GM02048AR GM02120AR GM02240AR GM02400AR GM02440AR Ref. No. 407726 407728 407730 407732 407734 407736 407738 407740 407742 407744 Comm. Closing Coil (1) GCCC024DR GCCC048R GCCC060DR GCCC120R GCCC240R GCCC277R GCCC400AR GCCC440AR Shunt GSTR024DR GSTR048R GSTR060DR GSTR120R GSTR240R GSTR277R GSTR400AR GSTR440AR 407771 407773 407775 407777 407779 407781 407783 407785 407835 407837 407839 407841 407843 407850 407851 407854 Cat. No. Ref. No.

Order codes

Closing Coil 2V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC Releases Undervoltage 2V DC 48V AC-DC 60V DC 110-130V AC-DC 220-240V AC-DC 277V AC; 250V DC 380- 415V AC 440V AC Auxiliary Contacts Power Rated 3NO & 3NC (Delivered as standard option in all EntelliGuard G breakers & Isolators) Power Rated 8NO & 8NC Power Rated 3NO & 3NC + Signal Rated 2NO & 2NC Power Rated 4NO & 4NC + Signal Rated 4NO & 4NC Bell Alarm Contacts 1 Changeover GBAT1R 407889 GAUX3R 407880 GUVT024DR GUVT048R GUVT060DR GUVT120R GUVT240R GUVT277R GUVT400AR GUVT440AR 407796 407798 407800 407802 407804 407806 407808 407810 GCCN024DR GCCN048R GCCN060DR GCCN120R GCCN240R GCCN277R GCCN400AR GCCN440AR 407860 407862 407864 407866 407868 407871 407876 407879

Intro A B C D E

GAUX6R GAUX5R GAUX8R

407882 407881 407883

Indication Contacts

F
CC/CCC/UVT/STR Release indicator

Power rated wired through sec. Discon. GCSP1R 407915

Signal rated wired Trip Unit (comm.) GCSP2R 407916

X
Position Indication Contacts Cassette Power rated on Cassette 1 Changeover per position 2 Changeovers per position GCPS1R GCPS2R 407924 407925

(1) Command closing coil allows breaker closure by means of a push-button located on the breaker front facia that is included in the kit. Optionally the Command close coil can be accessed via the Trip Unit (communication bus).

A.20

EntelliGuard G
Internal Accessories - Field mountable
Internal Accessories - Field mountable
For factory mounted variants see page A.17 & A.18

Locking Mechanisms (3) Ronis Cat. No. Mounted on Breaker The Ronis and Profalux devices allow 1 to 4 Locks to be placed. The Castell device 1 Mounted on Cassette (2 devices for 2 locks are possible) Associated Locks (2) Ronis 1104 B Lock (2) Profalux B204Y Lock (2) Castell FS1 lock/K4 key (2) GRON 407985 GPRO GCAS 407986 407987 GBRONR Ref. No. 407968 Castell Cat. No. GBCASR Ref. No. 407967 Profalux Cat. No. GBPROR Ref. No. 407979

GCRONR

407974

GCPROR

407981

Operation Front Fascia of Breaker Counter; number of Operations GMCNR 408033

(2) Not available as Factory Mounted accessory (3) Kirk Lock version available on request

Intro A B
Locking Mechanism Breaker Locking Mechanism Cassette Position Indication Contacts (per Pos.) Earthing Device

Internal Accessories - Field mountable


Maximum amount of installable internal accessories
Closing Coil or Command Closing Coil Auxiliary Contacts Power NO + NC Breaker Spring Charged indication Undervoltage Release* Breaker ready to close indication

Signaling Contacts Releases indic. HI.Fid.

Signaling Contacts Releases indic. Power

Bell Alarm contacts

Auxiliary Contacts Hi-Fidelity NO+NC

Network Interlock Release

Motor Operator type 1 or 2

Shunt Release

C D E F X

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0 2 1 1 0

1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1 1 2 0 1

0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 6 6 6 6 4 4 4 4 3 3 3 3 2 2 2 2

0 0 0 0 0 0 0 0 4 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 3 3 3 3 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 2 2 2 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 2 2 2 2 1 1 1 1 2 2 2 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

* TDM module (Time delay module) is mounted externally to the breaker.

A.21

EntelliGuard G
Internal Accessories - Field mountable
Not available in a factory mounted variant

Field mountable cables for interlocking of breakers (1) Interlock Type A B C

Interlock Scheme No. of Cables Needed 1 cable per breaker, choose length as indicated 1 cable per breaker, choose length as indicated 1 cable per breaker, choose length as indicated Brk's 1 and 3: 1 cable per breaker, choose length as indicated Brk. 2: 2 cables per breaker, choose length as indicated Cat. No. 60V DC 110-130V DC 220-240V DC 250V DC 48V AC 110-130V AC 220-240V AC 250-277V AC 380- 415V AC 440V AC GTDM060D GTDM120D GTDM240D GTDM250D GTDM048A GTDM120A GTDM240A GTDM277A GTDM400A GTDM440A 3 pole Ref. No. 407817 407819 407821 407823 407816 407818 407820 407822 407824 407825 4 pole 407930 407932 407934 407936 G16H6ED G20H6ED G40M6ED G64M6ED 407931 407933 407935 407937 Cat. No. Ref. No.

Cable length 1 metre Cable length 1.6 metre Cable length 2 metre Cable length 2.5 metre Cable length 3 metre Cable length 3.5 metre Cable length 4 metre

GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7

407990 407991 407992 407993 407994 407995 407996

Order codes

Time delay module for UVR release TDM

Cat. No.

Ref. No.

Intro
Breaker Earthing Device for Service

A B
GT- Accessories

EntelliGuard G type 1 Maximum 1600A Maximum 2000A EntelliGuard G type 2 Maximum 4000A EntelliGuard G type 3 Maximum 6400A Designation

G16H4ED G20H4ED G40M4ED G64M4ED

C D

Conditioning Power Supply 1 phase 220-230V(2) Conditioning Power Supply 1 phase 380-400V(2) Conditioning Power Supply 1 phase 240-250/277-290/415V(2) Power supply 222-265V AC-24VDC 0.22Amps(3)

GMPU1 GMPU2 GMPU3 GAPU

408790 408791 408792 408789

Trip unit, sealable transparent front cover

GTUS

408046

E F
Trip Unit Battery Tester and Set up unit GTUTK20 407999

Wall mounting Brackets Wall Mounting Brackets for Env. 1 & 2 GFMTG 408085

(1) See for associated breaker and or cassette mounted kits page A.18 (2) Obligatory when a fully functioning measurement unit is required (3) For GF settings below 0,2 x In this aux. supply is needed

A.22

EntelliGuard G
Installation Accessories
Not available in a factory mounted variant

Operation Front Fascia of Breaker Padlocking device for Pushbuttons

Cat. No.

Ref. No.

GPBD

408040

Installation Accessories

Operation Indicators Contact Wear Indicator env. 1-3

GCNTW

408036

Cassette Mis insertion device

GREPM

408041

Door Flanges & Interlocks Door Flange xed all types (1) Door Flange draw out all types (1) GDPRF GDPRW 408025 408026

Door Escutcheon IP54

G54DR

408038

Intro A B

Door Interlock on LEFT Door Interlock on RIGHT

GLHD GRHD

408039 408042

Lifting Breakers Lifting Truck for size EG-1 and EG-2 GLTK 408045

C
Adaptor for size EG-3 GLTA 408049

D
Phase seperators Set of 12 phase seperators for 1000V applications GJP 408057

E F

(1) is a spare, these devices are always supplied with the standard devices.

A.23

EntelliGuard G
Sensors for Trip Units
For use with Ground fault Residual (sum) protection Rogowski coils:
Envelope 1 Cat. No. 400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A G04HNRC G07HNRC G08HNRC G10HNRC G13HNRC G16HNRC G20HNRC Ref. No. 408000 408001 408002 408003 408004 408005 408006 Envelope 2 Cat. No. G04HNRC G07HNRC G08HNRC G10HNRC G13HNRC G16HNRC G20HNRC G25MNRC G32LNRC G40LNRC Ref. No. 408000 408001 408002 408003 408004 408005 408006 408162 408186 408187 Envelope 3 Cat. No. Ref. No.

Order codes

G32LNRC G40LNRC G50LNRC G64LNRC

408186 408187 408188 408189

Sensors for Trip Units


For use with Ground fault protection, Source Ground Return method Earth leg Current Transformers - Kits include 1 current transformer and 1 Interposing current transformer.
Envelope 1 Cat. No. Ref. No. 408300 408301 408302 408303 408304 408305 408006 400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6400A G04HNCT G07HNCT G08HNCT G10HNCT G13HNCT G16HNCT G20HNCT Envelope 2 Cat. No. G04HNCT G07HNCT G08HNCT G10HNCT G13HNCT G16HNCT G20HNCT G25MNCT G32LNCT G40LNCT Ref. No. 408300 408301 408302 408303 408304 408305 408006 408322 408331 408332 Envelope 3 Cat. No. Ref. No.

Intro A B C D E F X

G32LNCT G40LNCT G50LNCT G64LNCT

408331 408332 408333 408334

A.24

EntelliGuard G
Cassettes for use with Breakers & Isolators in Draw out Pattern; Field mountable
- References apply for Cassettes separately supplied for use with Breakers or Isolator - With Connection modes as indicated in left column - Each cassette is supplied with safety shutters

Cassettes for Draw out Pattern; xed portion only


Universal Rear Connections Rating (A) Suited for use with EntelliGuard G -G types 3 pole Cat. No. GG13H2UR GG16H2UR GG20H2UR GG20M2UR GG25M2UR GG32M2UR GG40M2UR Ref. No. 407602 407612 407622 407632 407642 407652 407666 Cat. No. GG13H5UR GG16H5UR GG20H5UR GG20M5UR GG25M5UR GG32M5UR GG40M5UR 4 pole* Ref. No. 407605 407615 407625 407635 407645 407656 407670

Sensors & Cassettes

Cassette for envelope 1 400 - 1250A GG, GJ & GW type S, N & H 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H Cassette for envelope 2 (1) 400 - 2000A GG, GJ & GW type N, E & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M 4000A GG, GJ & GW type N, H & M Remark: Each cassette is supplied with connection pads that can be rotated and used for Vertical or Horizontal connections. Cassette for envelope 3 (2) 3200 - 6400A* GG & GJ type G, M & L

GG64L2UR

407686

GG64L5UR

407688

Intro
Vertical rear Connections Cassette with dual vertical clusters and connection pads for limited de-rating envelope 2 3200A GH, GK, GJ & GZ type N.H & M 4000A GH, GK, GJ & GZ type N.H & M GH32M2VR GH40M2VR 408254 408267 GH32M5VR GH40M5VR 408255 408268

A B

Front access Connections Cassette for envelope 1 400 - 1250A GG, GJ & GW type S, N & H 1600A GG, GJ & GW type S, N & H 2000A GG, GJ & GW type S, N & H GG13H2FR GG16H2FR GG20H2FR 407600 407610 407620 GG13H5FR GG16H5FR GG20H5FR 407603 407613 407623

C D

Cassette for envelope 2 400 - 2000A GG, GJ & GW type E, N, H & M 2500A GG, GJ & GW type N, H & M 3200A GG, GJ & GW type N, H & M 4000A GG, GJ & GW type N, H & M

GG20M2FR GG25M2FR GG32M2FR GG40M2FR

407630 407640 407650 407658

GG20M5FR GG25M5FR GG32M5FR GG40M5FR

407633 407643 407654 407668

E F X

* 4th pole on Left. (1) Cassettes for envelope 2 are limited to a current of 3200A when connected in horizontal mode. Connected in vertical mode a 4000A rating is achieved (2) The Cassette for envelope 3 is limited to a current of 5000A when connected in horizontal mode. Connected in vertical mode it has a rating of 6400A. This cassette type is NOT depicted here

A.25

EntelliGuard G
Field Mounted (spare) Trip Units
Always specify Nominal current and Breaker serial Number on Ordering

GT- E
LT-C

Basic functionality

Designation GT-E Trip Unit with: LT-C 0.2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF I2T ON or OFF GFDB

Extended functionality None

Cat. No. GTG00K2-SR

Ref. No. 408802

LTDB

ST GF
2 I t on

I2 t on STDB

GT-Rating Plug

Required for all T types

GTPUNI

408860

Order codes

GFDB

GT- S
LT-C

LTDB

Intro
ST GF I2 t on STDB

GT-S Trip Unit LT-C 0.2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF I2T ON or OFF GFDB I GT-Rating Plug
Ii

Modbus Communication

GTG00K4-2SR

408809

Required for all types

GTPUNI

408860

A B
GT- N

I2 t on GFDB

C D

LT-C

LTDB

ST GF

GT-N Trip Unit LT-C 0.2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GF I2T ON or OFF GFDB I ext.
I2t on STDB Ihi

Measurement unit(1) Modbus Communication Zone Selective Interlock on ST, I & GF

GTG00K4T6SR

408819

GT-Rating Plug

Required for all types

GTPUNI

408860

E F

I2t on GFDB

(1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22

A.26

EntelliGuard G
Field Mounted (spare) Trip Units
Always specify Nominal current and Breaker serial Number on Ordering

GT- H

Basic functionality

Designation GT-H Trip Unit with: LT-C 0.2 -1 x In = Ir -ORLT-F 0.2 -1 x In = Ir LTDB ST I2T ON or OFF STDB GForGFA(2) sum.I2TONorOFF -AND/ORGForGFA(2) sum.I2TONorOFF GFDB I or I ext. RELT

Extended functionality

Cat. No.

Ref. No. 408849

LTDB

ST

I t on STDB Ihi GFDB

LT Band shape Choice (LTC or LTF) GTG00N5T8SR Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N7T8SR LT Band shape Choice (LTC or LTF) GTG00N5T9SR Dual GF Protection (Res./Sum or CT) Zone Selective Interlock on ST, I & GF Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication With standard Instaneous Idem with Extended Instananeous GTG00N7T9SR LT Band shape Choice (LTC or LTF) GTG00N6T8SR Dual GF Alarm (Res./Sum or CT) Zone Selective Interlock on ST, I & GFA Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Modbus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T8SR LT Band shape Choice (LTC or LTF) GTG00N6T9SR Dual GF Alarm (Res./Sum or CT) Zone Selective Interlock on ST, I & GFA Measurement Unit(1) Data aquisition & Relay functionality RELT Instantaneous Probus Communication With standard Instaneous Idem with Extended Instananeous GTG00N8T9SR

Electronic Trip Units

408851 408853

GF I t on
2

Extended functionality
LT-F

LTDB

408855 408850

RELTi

Intro
408852 408854

A B

408856 408860 408796

GT-Rating Plug GT Trip Unit with NO protection

Required for all types (For Non Automatic types)

GTPUNI G3G00KA-SR

C D E F X

(1) An auxiliary Power Conditioner is obligatory when a fully functioning measurement is required see page A.22 (2) Does NOT trip the associated EntelliGuard G Breaker, BUT produces an Alarm signal

A.27

EntelliGuard G
Spare Parts

Breaker Arc Chutes Envelope 1 Cat. No. Arc Chute for 1 pole G20HCHT Ref. No. 408102 Envelope 2 Cat. No. G40MCHT Ref. No. 408131 Envelope 3 Cat. No. G64LCHT Ref. No. 408144

Breaker Fixed Arcing Contacts Set for 1pole S & N types Set for 1pole H type Set for 1pole E & N types Set for 1pole H & M types Set for 1pole L type Cassette Shutters System with Interlock 3 pole System with Interlock 4 pole G20H2SSL G20H5SSL 407606 407607 G40M2SSL G40M5SSL 407636 407637 G64L2SSL G64L5SSL 407679 407680 G20NARC G20HARC 408104 408098 G40NARC G40MARC 408172 408169 G64LARC 408193

Order codes

Cassette Racking Handle

Intro A B C D E F X
Breakers and Cassette Spare Auxiliary Disconnect plugs Cassette Cluster Contacts Breaker front facia part *

Spare Racking Handle

GRHN

408043

GRHN

408043

GRHN

408043

Front Facia Set of 4 spare Lock cams for use with Ronis 1104 locks

GFA4 GRONCS

408028 407984

GFA4 GRONCS

408028 407984

GFA4 GRONCS

408028 407984

Sets per pole Current Rating 400-1250A Current Rating 1600A Current Rating 2000A Current Rating 2000A Current Rating 2500A Current Rating 3200A Current Rating 4000A Current Rating 5000A Current Rating 6400A Set of Universal Cluster Pliers

G13HCLS G16HCLS G20HCLS

408097 408100 408103 G20MCLS G25MCLS G32MCLS G40MCLS 408106 408109 408117 408120 G50LCLS G64LCLS 408145 408148 408047

GUNI

408047

GUNI

408047

GUNI

For Fixed Breaker 1 39 pole set For Fixed Breaker 1 78 pole set For Draw out Breaker 1 39 pole set (two can be mounted)

GSDFTR1 GSFDTR2 GSDWTR

408052 408029 408054

GSDFTR1 GSFDTR2 GSDWTR

408052 408029 408054

GSDFTR1 GSFDTR2 GSDWTR

408052 408029 408054

GT Trip Unit with NO protection (Suited for Non Automatic type) * The original breaker serial number must be indicated on ordering

G3G00KA-SR

408796

A.28

EntelliGuard G
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Intro A B C D E F X

A.29

Spare Parts

EntelliGuard G
Global Catalogue number structure - Breaker
- Codes built in the indicated manner can be used as an alternative ordering method - The breaker and its operation mode (Manual or Electrical)

1st digit
A product belonging to the EntelliGuard G breaker line

3rd & 4th digit


Nominal current rating of the product 400A 630A 04 07 08 10 13 16 20 25 32 40 50 64

6th digit
Fixed Pattern or Draw out Pattern moving portion and Number of Poles 3 Pole Fixed Pattern 3 pole Draw-out Moving Portion 4 Pole Fixed Pattern 4 pole Draw-out Moving Portion 4 1 6 3

7th digit
Electrically or Hand Operated Electrical at: 24V DC 48V DC 60V DC 110-130V DC 250V DC 48V AC 110-130V AC 230-240V AC 277V AC 380-415V AC 440V AC Manual A B C E F G H J K M N X

Order codes

800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A

Intro A B C
Product Type

5000A 6400A

D E F X

Circuit Breaker Circuit Breaker with reduced de-rating Non Automatic (Switch) no MCR Non Automatic (Switch) with MCR Non Automatic (Switch) 100% rated no MCR Non Automatic (Switch) 100% rated with MCR

G H J W K Z

Interruption / short-circuit withstand rating of the product Icu = Ics 50kA 65kA 85kA 85kA 100kA 100kA 150kA Icw 50kA 65kA 65kA 85kA 85kA 100kA 100kA Code S N H E M G L

Voltage Rating 24V DC 40-48VDC 48V AC 60V DC 110-130V AC-DC 220-240V AC-DC 250V DC 277V AC 380-415V AC 440V AC Manual

Standard Closing Coil A B D E G H K L X

Command Closing Coil(1) M P Q R T U W Y X

For an overview of the valid combinations indicating the available options see page A.34

If Electrically Operated add 1 Closing Coil by indicating voltage rating code. If manual use an X as indicated

2nd digit

5th digit

8th digit

(1) Is supplied with a Push Button for Local Breaker operation (ts on breaker front facia)

A.30

EntelliGuard G
Global Catalogue number structure - Breaker
- Codes built in the indicated manner can be used as an alternative ordering method - Breaker mounted accessories and Trip Unit

Global Catalogue number structure

9th digit
Shunt Release Voltage Rating 24V DC 40-48VDC 48V AC 60V DC 110-130V AC-DC 220-240V AC-DC 250V DC 277V AC 380-415V AC 440V AC Network Interlock None Code A B D E G H K L 1 X

11th digit
2nd Shunt or UVR Release Voltage Rating 24V DC 40-48VDC 48V AC 60V DC 110-130V AC-DC 220-240V AC-DC 250V DC 277V AC 380-415V AC 440V AC None Shunt code A C D E G H K L X UVR code 1 3 4 5 7 8 W Y

13th digit
Bell Alarm Switch & Operations Counter Bell Alarm 1 NO Mechanical Operations Counter Bell Alarm 1NO & Mechanical Operations counter Ready to Close contact 1 NO Power Rated on Secondary terminals Ready to Close contact 1 NO Signal Rated on Secondary terminals Ready to Close contact 1 NO Signal Rated connected through Trip Unit None A B C 1 2 3 X X Ready to Close contact 1 NO Power Rated on Secondary terminals X Ready to Close contact 1 NO SIgnal Rated on Secondary terminals X Ready to Close contact 1 NO SIgnal Rated connected Through Trip Unit Code to be added D K G E L H F M J

X No other contacts installed

Add 1st Shunt Release by indicating voltage rating code. if not needed use an X as indicated, or '1' for a network Interlock

Add a 2nd or UVR Shunt Release by indicating the voltage rating code. if not needed use an X as indicated.

Intro A B C

Undervoltage Release Voltage Rating 24V DC 40-48VDC 48V AC 60V DC 110-130V AC-DC 220-240V AC-DC 250V DC 277V AC 380-415V AC 440V AC None Code 1 3 4 5 7 8 W

Auxiliary Switches & Conguration 3NO+3NC (Power Rated)(2) 8NO+8NC (Power Rated) 3NO/3NC (Power Rated) + 2NO/2NC (Signal) 4NO/4NC (Power Rated) + 4NO/4NC Signal) 2 4 6 8 J K L A B C

Code to be added D E F

(2)

D E F X

Add 1st UVR release by using the indicated code. If a 1 is chosen as a 9th digit the use of a Network Interlock with equivalent voltage is assumed. The use of an X indicates no Release installed.

Add one of the chosen combinations by using one of the indicated codes.

10th digit

12th digit

(2) Each standard breaker or Isolator is normally supplied with 3 NO+3NC Aux.contacts (option 2)

No other contacts installed

Coil Signaling Contact Power (1 NO on Secondary Disconnect) - Close Coil or command close coil Coil Signaling Contact High Fidelity through Trip Unit Close Coil or command close coil Coil Signaling Contact Power (1 NO on Secondary Disconnect) - 1st Shunt Coil Signaling Contact High Fidelity through Trip Unit - 1st Shunt Coil Signaling Contact Power (1 NO on Secondary Disconnect) - 1st UVR Coil Signaling Contact High Fidelity through Trip Unit - 1st UVR Coil Signaling Contact Power (1 NO on Secondary Disconnect) - 2nd ST or 2nd UVR through Trip Unit - 2nd ST or 2nd UVR Coil Signaling Contact High Fidelity Coil Signaling Contact Power (1 NO on Secondary Disconnect) - All installed devices CC/CCC, ST, or UVR Coil Signaling Contact Hight Fidelity (1 NO - Through Trip Unit) - All installed devices. CC/CCC, ST, or UVR

A.31

EntelliGuard G
Global Catalogue number structure - Breaker
- Codes built in the indicated manner can be used as an alternative ordering method - Breaker mounted accessories and Trip Unit

14th digit
Factory Installed prevision to mount a Key lock on the breakers For Ronis or Profalux Key lock For Kirk Key lock For Castell type Key lock No prevision for Key lock R

16th, 17th & 18th digit


Denes Installed GT type Electronic Trip Unit Basic type GT-E with Ammeter GT-S with Ammeter Optional Communication S Code E Functionality LT, LTDB. ST, STDB LT, LTDB. ST, STDB, GF, GFDB LT, LTDB. ST, STDB, I LT, LTDB. ST, STDB, I, GF, GFDB LT, LTDB. ST, STDB, I, GF, GFDB * Modbus communication LT, LTDB. ST, STDB, HI, GF, GFDB LT, LTDB. ST, STDB, HI, GF, GFDB * Modbus communication LT, LTDB. ST, STDB, I LT, LTDB. ST, STDB, I, GF, GFDB LT, LTDB. ST, STDB, I, GF, GFDB + ZSI on ST and GF + Modbus communication LT, LTDB. ST, STDB, HI, GF, GFDB LT, LTDB. ST, STDB, HI, GF, GFDB + ZSI on ST and GF + Modbus communication Code 01 02 06 07 09 03 05 08 10 11 04 12

19th digit
Denes instruction manual language English German Polish English Dutch French Spanish Portuguese Italian Russian Rumanian Bulgarian A

Order codes

K C X

GT-N with Measurement Optional Communication N

Intro A B C D E F X
Factory Installed prevision to mount a Cable interlock between breakers Mechanical Interlock Type A Mechanical Interlock Type B Mechanical Interlock Type C Mechanical Interlock Type D No prevision for Breaker interlock 1 With Measurement, Relaying and Wave form capture Optional, Modbus or Probus Communication

23

Denes Installed GT type Electronic Trip Unit Basic type GT-H Code Functionality LT+ (C+F),LTDB,ST,STDB.GF+EF,HI LT+ (C+F),LTDB,ST,STDB.GF+EF,HI + Modbus Communication LT+ (C+F),LTDB,ST,STDB.GF+EF,HI + Probus Communication H LT+ (C+F),LTDB,ST,STDB.GF+EF,HI ZSI on ST, GF & HI LT+ (C+F),LTDB,ST,STDB.GF+EF,HI ZSHI on ST, GF & HI + Modbus Communication LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI Code 13 14 15 16 Functionality LT+ (C+F),LTDB,ST,STDB.GF+EF,I ZSI on ST, GF & I + Modbus Communication LT+ (C+F),LTDB,ST,STDB.GF+EF,I ZSI on ST, GF & I + Probus Communication LT+(C+F),LTDB,ST,STDB.GFA+EFA,& I LT+(C+F),LTDB,ST,STDB.GFA+EFA, I + Modbus Communication + Modbus Communication LT+(C+F),LTDB,ST,STDB.GFA+EFA, I + Probus Communication LT+C+F),LTDB,ST,STDB. GFA+EFA,IZSI on ST, GFA & I LT+(C+F),LTDB,ST,STDB. GFA+EFA,IZSI on ST, GFA & I + Modbus Communication LT+(C+F),LTDB,ST,STDB.GFA+EFA, I, ZSI on ST, GFA & I + Probus Communication LT+ (C+F),LTDB,ST,STDB.I + Modbus Communication LT+ (C+F),LTDB,ST,STDB.I + Probus Communication LT+(C+F),LTDB,ST,STDB.GF+EF,HI + Probus Communication LT+C+F),LTDB,ST,STDB.GFA+EFA,HI ZSI on ST, GFA & HI + Probus Communication Code 28

29 30 31 32 33

17 18 19 20 21 22 23 24 25 26 27

LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI + Modbus Communication LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI + Probus Communication LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI ZSI on ST, GFA & HI LT+ (C+F),LTDB,ST,STDB.GFA+EFA,HI ZSI on ST, GFA & HI + Modbus Communication LT+ (C+F),LTDB,ST,STDB.I LT+ (C+F),LTDB,ST,STDB.GF+EF,I LT+ (C+F),LTDB,ST,STDB.GF+EF,I + Modbus Communication LT+ (C+F),LTDB,ST,STDB.GF+EF,I + Probus Communication LT+ (C+F),LTDB,ST,STDB.GF+EF,I ZSI on ST, GF & I

34

35

15th digit

36 37 38

39

A.32

EntelliGuard G
Global Catalogue number structure - Cassette

Global Catalogue number structure

- Codes built in the indicated manner can be used as an alternative ordering method - Cassettes supplied together with the breaker

1st digit
A product belonging to the EntelliGuard G breaker line

3rd & 4th digit


Nominal current rating of the product 1250A 1600A 2000A 2500A 3200A 4000A 6400A 13 16 20 25 32 40 64

6th digit
Number of Poles of the Cassette 3 Pole 4 pole 2 5

7th digit
Connection Mode Rear Universal, T stubs rotatable -Horizontal or Vertical busbars Front Flat access Rear Horizontal busbars Rear Vertical busbars

9th digit
Position Indication switches in Cassette U F H V Set of 1 NO and 1NC contacts per Position Set of 2 NO and 2NC contacts per Position No Switches Mounted 2 4

Intro A
G G 13 H 2 U X X X

B C

Suitable for: Standard Circuit Breaker or standard Non Automatic type Circuit Breaker or standard Non Automatic type with reduced derating

Maximum interruption / short-circuit withstand rating of the Breaker used with the Cassette G Icu = Ics 85kA 100kA H 150kA Icw 65kA 85kA 100kA Code H M L

Delivered mounted with breaker or separately** Mounted with breaker Delivered as separate component M R

Factory Installed prevision to mount a Key lock on the cassette For 1 Ronis Key lock For 2 Ronis Key locks For 1 Profalux Key lock For 2 Profalux Key locks No Lock Prevision mounted R S P Q X

D E F

2nd digit

5th digit

8th digit

10th digit*

For an overview of the valid combinations indicating the available options see page A.34
* 11 and 12th digit reserved for future use ** The 10th and 11th digit are reserved for future expansion of the ordering code system (An X or - is used as temporary ller)

A.33

EntelliGuard G
Valid Catalogue number combinations
Factory mounted: Available standard Breaker & Cassette types

3 pole Breakers in Fixed Pattern Cat. No GG04E4 GG04H4 GG04M4 GG04N4 GG04S4 GG07E4 GG07H4 GG07M4 GG07N4 GG07S4 GG08E4 GG08H4 GG08M4 GG08N4 GG08S4 GG10E4 GG10H4 GG10M4 GG10N4 GG10S4 GG13E4 GG13H4 GG13M4 GG13N4 GG13S4 GG16E4 GG16H4 GG16M4 GG16N4 GG16S4 GG20E4 GG20H4 GG20M4 GG20N4 GG20S4 GG25H4 GG25M4 GG25N4 GG32G4 GG32H4 GG32L4 GG32M4 GG32N4 GG40G4 GG40H4 GG40L4 GG40M4 GG40N4 GG44L4 GG44M4 GG50L4 GG50M4 Ref. No. 407003 407007 407011 407015 407019 407032 407036 407040 407044 407048 407062 407066 407070 407074 407078 407092 407096 407100 407104 407108 407122 407126 407130 407134 407138 407152 407156 407160 407164 407168 407192 407196 407200 407204 407208 407232 407236 407240 407252 407244 407254 407262 407266 407270 407280 407284 407288 407292 407322 407326 407302 407306 Page A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4

4 pole Breakers in Fixed Pattern Cat. No GG04E6 GG04H6 GG04M6 GG04N6 GG04S6 GG07E6 GG07H6 GG07M6 GG07N6 GG07S6 GG08E6 GG08H6 GG08M6 GG08N6 GG08S6 GG10E6 GG10H6 GG10M6 GG10N6 GG10S6 GG13E6 GG13H6 GG13M6 GG13N6 GG13S6 GG16E6 GG16H6 GG16M6 GG16N6 GG16S6 GG20E6 GG20H6 GG20M6 GG20N6 GG20S6 GG25H6 GG25M6 GG25N6 GG32H6 GG32G6 GG32L6 GG32M6 GG32N6 GG40G6 GG40H6 GG40L6 GG40M6 GG40N6 GG50L6 GG50M6 GG64L6 GG64M6 Ref. No. 407004 407008 407012 407016 407020 407033 407037 407041 407045 407049 407063 407067 407071 407075 407079 407093 407097 407101 407105 407109 407123 407127 407131 407135 407139 407153 407157 407161 407165 407169 407193 407197 407201 407205 407209 407233 407237 407241 407245 407253 407255 407263 407267 407271 407281 407285 407289 407293 407303 407307 407323 407327 Page A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4 A.4

3 pole Breakers; Draw out Portion only Cat. No GG04E1 GG04H1 GG04M1 GG04N1 GG04S1 GG07E1 GG07H1 GG07M1 GG07N1 GG07S1 GG08E1 GG08H1 GG08M1 GG08N1 GG08S1 GG10E1 GG10H1 GG10M1 GG10N1 GG10S1 GG13E1 GG13H1 GG13M1 GG13N1 GG13S1 GG16E1 GG16H1 GG16M1 GG16N1 GG16S1 GG20E1 GG20H1 GG20M1 GG20N1 GG20S1 GG25H1 GG25M1 GG25N1 GG32G1 GG32H1 GG32L1 GG32M1 GG32N1 GG40G1 GG40H1 GG40L1 GG40M1 GG40N1 GG50L1 GG50M1 GG64L1 GG64M1 GH32H1 GH32M1 GH32N1 GH40H1 GH40M1 GH40N1 Ref. No. 407001 407005 407009 407013 407017 407030 407034 407038 407042 407046 407060 407064 407068 407072 407076 407090 407094 407098 407102 407106 407120 407124 407128 407132 407136 407150 407154 407158 407162 407166 407190 407194 407198 407202 407206 407230 407234 407238 407250 407242 407248 407260 407264 407268 407278 407282 407286 407290 407300 407304 407320 407324 407346 407348 407350 407352 407354 407356 Page A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.9 A.9 A.9 A.9 A.9 A.9

3 pole Breakers; Standard Cassette for Draw out portion Cat. No GG13H2FM GG13H2UM GG16H2FM GG16H2UM GG20H2FM GG20H2UM GG20M2FM GG20M2UM GG25M2FM GG25M2UM GG32M2FM GG32M2UM GG40M2FM GG40M2UM GG64L2UM GH32M2VM GH40M2VM Ref. No. 407690 407692 408200 408202 408210 408212 408222 408224 408234 408236 408245 408247 408257 408259 408281 408292 408294 Page A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11

Intro A B C D E F X

Order codes
A.34

EntelliGuard G
Valid Catalogue number combinations
Factory mounted: Available standard Breaker, Cassette and Trip Unit types

Catalogue number combinations

4 pole Breakers; Draw out Portion only Cat. No GG04E3 GG04H3 GG04M3 GG04N3 GG04S3 GG07E3 GG07H3 GG07M3 GG07N3 GG07S3 GG08E3 GG08H3 GG08M3 GG08N3 GG08S3 GG10E3 GG10H3 GG10M3 GG10N3 GG10S3 GG13E3 GG13H3 GG13M3 GG13N3 GG13S3 GG16E3 GG16H3 GG16M3 GG16N3 GG16S3 GG20E3 GG20H3 GG20M3 GG20N3 GG20S3 GG25H3 GG25M3 GG25N3 GG32G3 GG32H3 GG32L3 GG32N3 GG40G3 GG40H3 GG40L3 GG40M3 GG40N3 GG50L3 GG50M3 GG64L3 GG64M3 GGM3M3 GH32H3 GH32M3 GH32N3 GH40H3 GH40M3 GH40N3 Ref. No. 407002 407006 407010 407014 407018 407031 407035 407039 407043 407047 407061 407065 407069 407073 407077 407091 407095 407099 407103 407107 407121 407125 407129 407133 407137 407151 407155 407159 407163 407167 407191 407195 407199 407203 407207 407231 407235 407239 407251 407273 407249 407265 407269 407279 407283 407287 407291 407301 407305 407321 407325 407261 407347 407349 407351 407353 407355 407357 Page A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.8 A.9 A.9 A.9 A.9 A.9 A.9

4 pole Breakers; Standard Cassette for Draw out portion Cat. No GG13H5FM GG13H5UM GG16H5FM GG16H5UM GG20H5FM GG20H5UM GG20M5FM GG20M5UM GG25M5FM GG25M5UM GG32M5FM GG32M5UM GG40M5FM GG40M5UM GG64L5UM GH32M5VM GH40M5VM Ref. No. 407693 407695 408203 408205 408213 408215 408225 408227 408237 408239 408249 408251 408261 408263 408283 408293 408295 Page A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 Cat. No

Global Trip Units Ref. No. 408800 408801 408807 408815 408805 408817 408808 408816 408806 408818 408813 408803 408825 408833 408841 408829 408837 408845 408826 408834 408842 408830 408838 408846 408827 408835 408843 408831 408839 408847 408828 408836 408844 408832 408840 408848 408823 408863 408865 408860 408860 408860 408860 408860 408860 408860 408860 408860 408860 408860 408860 Page A.12 A.12 A.12 A.13 A.12 A.13 A.12 A.13 A.12 A.13 A.13 A.12 A.14 A.14 A.14 A.14 A.14 A.14 A.16 A.16 A.16 A.16 A.16 A.16 A.15 A.15 A.15 A.15 A.15 A.15 A.16 A.16 A.16 A.16 A.16 A.16 A.14 A.14 A.14 A.12 A.12 A.12 A.12 A.12 A.13 A.13 A.13 A.14 A.14 A.15 A.16

GTG00K1-SF GTG00K2-SF GTG00K3-2SF GTG00K3-4SF GTG00K3-SF GTG00K3T6SF GTG00K4-2SF GTG00K4-4SF GTG00K4-SF GTG00K4T6SF GTG00K9-4SF GTG00K9-SF GTG00N5-5SF GTG00N5-8SF GTG00N5-9SF GTG00N5T5SF GTG00N5T8SF GTG00N5T9SF GTG00N6-5SF GTG00N6-8SF GTG00N6-9SF GTG00N6T5SF GTG00N6T8SF GTG00N6T9SF GTG00N7-5SF GTG00N7-8SF GTG00N7-9SF GTG00N7T5SF GTG00N7T8SF GTG00N7T9SF GTG00N8-5SF GTG00N8-8SF GTG00N8-9SF GTG00N8T5SF GTG00N8T8SF GTG00N8T9SF GTG00N9-5SF GTG00N9-8SF GTG00N9-9SF GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI GTPUNI

Intro A B C D E F X

A.35

EntelliGuard G
Valid Catalogue number combinations
Factory mounted: Available standard Isolator & Cassette types

3 pole Isolators in Fixed Pattern Cat. No GJ04S4 GJ07S4 GJ08S4 GJ10S4 GJ13S4 GJ16S4 GJ20S4 GJ25N4 GJ32L4 GJ32N4 GJ40L4 GJ40N4 GJ50L4 GJ64L4 GW04M4 GW04N4 GW07M4 GW07N4 GW08M4 GW08N4 GW10M4 GW10N4 GW13M4 GW13N4 GW16M4 GW16N4 GW20M4 GW20N4 GW25M4 GW32M4 GW40M4 Ref. No. 407380 407400 407420 407440 407460 407480 407500 407520 407535 407539 407556 407560 407567 407577 408350 407376 408352 407396 408354 407416 408356 407436 408358 407456 408360 407476 408362 407496 408364 408366 408368 Page A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5

4 pole Isolators in Fixed Pattern Cat. No GJ04S6 GJ07S6 GJ08S6 GJ10S6 GJ13S6 GJ16S6 GJ20S6 GJ25N6 GJ32L6 GJ32N6 GJ40L6 GJ40N6 GJ50L6 GJ64L6 GW04M6 GW04N6 GW07M6 GW07N6 GW08M6 GW08N6 GW10M6 GW10N6 GW13M6 GW13N6 GW16M6 GW16N6 GW20M6 GW20N6 GW25M6 GW32M6 GW40M6 Ref. No. 407381 407401 407421 407441 407461 407481 407501 407521 407536 407540 407557 407561 407568 407578 408351 407377 408353 407397 408355 407417 408357 407437 408359 407457 408361 407477 408363 407497 408365 408367 408369 Page A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5

3 pole Isolators; Draw out Portion only Cat. No GJ04S1 GJ07S1 GJ08S1 GJ10S1 GJ13S1 GJ16S1 GJ20S1 GJ25N1 GJ32L1 GJ32N1 GJ40L1 GJ40N1 GJ50L1 GJ64L1 GK32N1 GK40N1 GW04M1 GW04N1 GW07M1 GW07N1 GW08M1 GW08N1 GW10M1 GW10N1 GW13M1 GW13N1 GW16M1 GW16N1 GW20M1 GW20N1 GW25M1 GW32M1 GW40M1 GZ32H1 GZ40H1 Ref. No. 407378 407398 407418 407438 407458 407478 407498 407518 407533 407537 407554 407558 407565 407575 407591 407595 408400 407374 408402 407394 408404 407414 408406 407434 408408 407454 408410 407474 408412 407494 408414 408416 408418 407589 407593 Page A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10

3 pole Isolators; Standard Cassette for Draw out portion Cat. No GG13H2FM GG13H2UM GG16H2FM GG16H2UM GG20H2FM GG20H2UM GG20M2FM GG20M2UM GG25M2FM GG25M2UM GG32M2FM GG32M2UM GG40M2FM GG40M2UM GG64L2UM GH32M2VM GH40M2VM Ref. No. 407690 407692 408200 408202 408210 408212 408222 408224 408234 408236 408245 408247 408257 408259 408281 408292 408294 Page A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11

Intro A B C D E F X

Order codes
A.36

EntelliGuard G
Valid Catalogue number combinations
Factory mounted: Available standard Isolator & Cassette types

Catalogue number combinations

4 pole Isolators; Draw out Portion only Cat. No GJ04S3 GJ07S3 GJ08S3 GJ10S3 GJ13S3 GJ16S3 GJ20S3 GJ25N3 GJ32L3 GJ32N3 GJ40L3 GJ40N3 GJ50L3 GJ64L3 GK32N3 GK40N3 GW04M3 GW04N3 GW07M3 GW07N3 GW08M3 GW08N3 GW10M3 GW10N3 GW13M3 GW13N3 GW16M3 GW16N3 GW20M3 GW20N3 GW25M3 GW32M3 GW40M1 GZ32H3 GZ40H3 Ref. No. 407379 407399 407419 407439 407459 407479 407499 407519 407534 407538 407555 407559 407566 407576 407592 407596 408401 407375 408403 407395 408405 407415 408407 407435 408409 407455 408411 407475 408413 407495 408415 408417 408418 407590 407594 Page A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10

4 pole Isolators; Standard Cassette for Draw out portion Cat. No GG13H5FM GG13H5UM GG16H5FM GG16H5UM GG20H5FM GG20H5UM GG20M5FM GG20M5UM GG25M5FM GG25M5UM GG32M5FM GG32M5UM GG40M5FM GG40M5UM GG64L5UM GH32M5VM GH40M5VM Ref. No. 407693 407695 408203 408205 408213 408215 408225 408227 408237 408239 408249 408251 408261 408263 408283 408293 408295 Page A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11

Intro A B C D E F X

A.37

EntelliGuard G
Valid Catalogue number combinations
Accessories; Factory and Field mountable

Factory Mounted Accessories Cat. No GAUX5 GAUX6 GAUX8 GBAT1 GBCAS GBPRO GBRON GCCC024D GCCC048 GCCC060D GCCC120 GCCC240 GCCC277 GCCC400A GCCC440A GCCN024D GCCN048 GCCN060D GCCN120 GCCN240 GCCN277 GCCN400A GCCN440A GCPRO GCPS1 GCPS2 GCRON GCSP1 GCSP2 GM01024D GM01048A GM01048D GM01060D GM01110D GM01120A GM01240A GM01250D GM01400A GM01440A GM02024D GM02048A GM02048D GM02060D GM02110D GM02120A GM02240A GM02250D GM02400A GM02440A GMCN GSTR024D GSTR048 GSTR060D GSTR120 GSTR240 GSTR277 GSTR400A GSTR440A GUVT024D GUVT048 GUVT060D GUVT120 GUVT240 GUVT277 GUVT400A GUVT440A Ref. No. 407886 407887 407888 407891 407970 407978 407971 407836 407838 407840 407842 407844 407849 407852 407853 407861 407863 407865 407867 407869 407870 407877 407878 407980 407922 407923 407976 407895 407896 407700 407710 407702 407704 407706 407712 407714 407708 407716 407718 407725 407735 407727 407729 407731 407737 407739 407733 407741 407743 408035 407770 407772 407774 407776 407778 407780 407782 407784 407795 407797 407799 407801 407803 407805 407807 407809 Page A.17 A.17 A.17 A.17 A.18 A.18 A.18 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.18 A.17 A.17 A.18 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.18 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17 A.17

Field Mountable Alternative versions Cat. No GAUX5R GAUX6R GAUX8R GBAT1R GBCASR GBPROR GBRONR GCCC024DR GCCC048R GCCC060DR GCCC120R GCCC240R GCCC277R GCCC400AR GCCC440AR GCCN024DR GCCN048R GCCN060DR GCCN120R GCCN240R GCCN277R GCCN400AR GCCN440AR GCPROR GCPS1R GCPS2R GCRONR GCSP1R GCSP2R GM01024DR GM01048AR GM01048DR GM01060DR GM01110DR GM01120AR GM01240AR GM01250DR GM01400AR GM01440AR GM02024DR GM02048AR GM02048DR GM02060DR GM02110DR GM02120AR GM02240AR GM02250DR GM02400AR GM02440AR GMCNR GSTR024DR GSTR048R GSTR060DR GSTR120R GSTR240R GSTR277R GSTR400AR GSTR440AR GUVT024DR GUVT048R GUVT060DR GUVT120R GUVT240R GUVT277R GUVT400AR GUVT440AR Ref. No. 407881 407882 407883 407889 407967 407979 407968 407835 407837 407839 407841 407843 407850 407851 407854 407860 407862 407864 407866 407868 407871 407876 407879 407981 407924 407925 407974 407915 407916 407701 407711 407703 407705 407707 407713 407715 407709 407717 407719 407726 407736 407728 407730 407732 407738 407740 407734 407742 407744 408033 407771 407773 407775 407777 407779 407781 407783 407785 407796 407798 407800 407802 407804 407806 407808 407810 Page A.20 A.20 A.20 A.20 A.21 A.21 A.21 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.21 A.20 A.20 A.21 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.21 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20 A.20

Accessories only available as Factory Mounted types Cat. No GI2FAD GI2WAD GI3FB GI3FC GI3FDT GI3WB GI3WC GI3WDT GNTK120 GNTK240 GRTC1 GRTC2 GRTC3 Ref. No. 407900 407901 407902 407904 407906 407903 407905 407907 407753 407754 407897 407899 407894 Page A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.17 A.17 A.17 A.17 A.17

Accessories only available in Field Mountable versions Cat. No G16H4ED G16H4FFI G16H6ED G16H6FFI G20H4ED G20H4FFI G20H4RVI G20H6ED G20H6FFI G20H6RVI G32M4FFI G32M4RVI G32M6FFI G32M6RVI G40M4ED G40M4FFI G40M4RVI G40M6ED G40M6FFI G40M6RVI G54DR G64L4RVI G64L6RVI G64M4ED G64M6ED GAPU GAUX3R GCAS GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 GCNTW GDPRF GDPRW GFMTG GJP GLHD GLTA GLTK GMPU1 GMPU2 GMPU3 GPBD GPRO GREPM GRHD GRON GRONCS GTDM048A GTDM060D GTDM120A GTDM120D GTDM240A GTDM240D GTDM250D GTDM277A GTDM400A GTDM440A GTUS GTUTK20 Ref. No. 407930 408060 407931 408062 407932 408061 408064 407933 408063 408065 408066 408070 408068 408071 407934 408067 408072 407935 408069 408074 408038 408073 408075 407936 407937 408789 407880 407986 407990 407991 407992 407993 407994 407995 407996 408036 408025 408026 408085 408057 408039 408049 408045 408790 408791 408792 408040 407987 408041 408042 407985 407984 407816 407817 407818 407819 407820 407821 407823 407822 407824 407825 408046 407999 Page A.22 A.6 A.22 A.6 A.22 A.6 A.6 A.22 A.6 A.6 A.6 A.6 A.6 A.6 A.22 A.6 A.6 A.22 A.6 A.6 A.23 A.6 A.6 A.22 A.22 A.22 A.20 A.21 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.23 A.23 A.23 A.6 A.23 A.23 A.23 A.23 A.22 A.22 A.22 A.23 A.21 A.23 A.23 A.21 A.28 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22

Intro A B C D E F X

Order codes
A.38

EntelliGuard G
Valid Catalogue number combinations
Accessories, Sensors, Cassettes, Trip Units ans Spares

Catalogue number combinations

Sensors (CT & Rogowski) for Ground & Earth fault options Cat. No G04HNCT G04HNRC G07HNCT G07HNRC G08HNCT G08HNRC G10HNCT G10HNRC G13HNCT G13HNRC G16HNCT G16HNRC G20HNCT G20HNRC G25MNCT G25MNRC G32LNCT G32LNRC G40LNCT G40LNRC G50LNCT G50LNRC G64LNCT G64LNRC Ref. No. 408300 408000 408301 408001 408302 408002 408303 408003 408304 408004 408305 408005 408306 408006 408322 408162 408331 408186 408332 408187 408333 408188 408334 408189 Page A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24

Separately available Standard Cassette for Draw out portion Cat. No GG13H2F-R GG13H2U-R GG13H5F-R GG13H5U-R GG16H2F-R GG16H2U-R GG16H5F-R GG16H5U-R GG20H2F-R GG20H2U-R GG20H5F-R GG20H5U-R GG20M2F-R GG20M2U-R GG20M5F-R GG20M5U-R GG25M2F-R GG25M2U-R GG25M5F-R GG25M5U-R GG32M2F-R GG32M2U-R GG32M5F-R GG32M5U-R GG40M2F-R GG40M2U-R GG40M5F-R GG40M5U-R GG64L2U-R GG64L5U-R GH32M2V-R GH32M5V-R GH40M2V-R GH40M5V-R Ref. No. 407600 407602 407603 407605 407610 407612 407613 407615 407620 407622 407623 407625 407630 407632 407633 407635 407640 407642 407643 407645 407650 407652 407654 407656 407658 407666 407668 407670 407686 407688 408254 408255 408267 408268 Page A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25

Separately available Plug & Play Trip Units Cat. No GTG00K2-SR GTG00K4-2SR GTG00K4T6SR GTG00N5T8SR GTG00N5T9SR GTG00N6T8SR GTG00N6T9SR GTG00N7T8SR GTG00N7T9SR GTG00N8T8SR GTG00N8T9SR GTPUNI Ref. No. 408802 408809 408819 408849 408853 408850 408854 408851 408855 408852 408856 408860 Page A.26 A.26 A.26 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.12

Separately available Spare Parts Cat. No G13HCLS G16HCLS G20H2SSL G20H5SSL G20HARC G20HCHT G20HCLS G20MCLS G20NARC G25MCLS G32MCLS G40M2SSL G40M5SSL G40MARC G40MCHT G40MCLS G40NARC G50LCLS G64L2SSL G64L5SSL G64LARC G64LCHT G64LCLS GFA4 GFA6 GRHN GSDFTR GSDWTR GUNI Ref. No. 408097 408100 407606 407607 408098 408102 408103 408106 408104 408109 408117 407636 407637 408169 408131 408120 408172 408145 407679 407680 408193 408144 408148 408028 408029 408043 408052 408054 408047 Page A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28

Intro A B C D E F X

A.39

EntelliGuard G
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Intro A B C D E F X

EntelliGuard G
Electronic Trip Units B.2 B.3 B.4 B.5 B.6 B.7 B.8 B.9 B.10 B.11 B.12 B.13 B.14 B.15 B.16 B.17 B.18 Electronic Trip Units layout & Main menu Overload Protection LT-C and LTD Overload Protection LT-F and LTD Table indicating available Long Time settings Short-circuit Protection ST and STDB Short-circuit Protection ST and I2T slope Short-circuit Protection; Instantaneous (I) Overcurrent Protection Against Short-circuit: Extended Range Short-circuit Protection temporary reduced I (RELT) Setting limitations of Short-circuit devices - Short-circuit Protection: HSIOC, MCR Ground fault Protection: GF and GFD (Residual Type) Ground fault Protection: GF and I2t slope Ground Fault Protection Zone Selective Interlock, Load Shedding and Trip Indication Measurement Functions and Power Supplies Protective Relaying Functions; Relay and Trip Unit Inputs Wave Form Capture Option Communications Neutral protection, Reset Choice Rating Plug and Test Kit

The breaker Order Codes

Intro A B C D E F X

Electronic Trip Units


B.19 Overview of GT Electronic Trip Unit Functionality

Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

Time Current Curves (cold state) B.20 B.21 B.22 B.23 B.24 B.25 B.26 B.27 B.28 LT Protection Device LT Protection Device LT & ST Protection Device ST Protection Device ST and I Protection Device HSIOC & GF Protection Device GF Protection Device Terminology Example of Full Time Current Curve

B.1

EntelliGuard G
Electronic Trip Units layout & Main menu
State of the Art Electronic Trip Unit All EntelliGuard G Power Circuit Breakers are equipped with a digital electronic trip unit, available in four basic versions E, S, N and H. Each has a common design that comes with a screen providing an ammeter and allowing a simple and accurate menu driven adjustment of the breaker parameters across a broad current range. All functionality is menu driven accessed by using 4 setting and one enter key thus allowing a fast and accurate setting of the device. These have the following functionality: UP: Scroll up, Increment Value DOWN: Scroll down, Decrement value NEXT function, next page PREVIOUS function, previous page SAVE setting into memory After inserting the Universal rating plug, the device can be adjusted and the installed options set. In situations where the installation is not yet connected to the power supply, the use of the separately available TESTER with Power Pack is advised (Cat No. GTUTK20). Alternatively the internal Trip Unit Battery power pack can be used. Depressing any key on the face of the trip unit powers the unit from its internal battery. Battery power is maintained for 20 seconds after the last key is pressed. All normal setup, meter, and status functions can be performed with battery power. In Power On situations the Trip Unit display is only functional when the breaker is carrying at least 20% of its nominal current value (Single phase). SET UP MENU To enter this option begin the process by pressing the UP or DOWN key until SETUP is selected on the screen. Pressing the NEXT or PREVIOUS key allows one to enter the setup mode. After selecting this mode, all functions can be chosen by depressing the NEXT or PREVIOUS key. Within the setup menu all breaker protection values, trip unit parameters, relaying functions in and outputs, communication and trip unit access codes are set Each EntelliGuard G Electronic trip units provides long-time over-current protection (LT), longtime delay (LTD) and some form of Short-circuit over-current protection (ST and/or I, H, RELT). Depending on the chosen Trip Unit Tier or Type and the selected options a, host of other protection, metering relaying functions and a wave form capture option are available. In the following pages each of these functions are described in detail. A set of tabs placed below each description indicate in which Trip Unit Tier the described function is present. METER To enter this option begin the process by pressing the UP or DOWN key until to METER is selected on the screen. Pressing the NEXT or PREVIOUS key allows one to view various groups of measurements as Current, Voltage, real, apparent and reactive Power for the electrical system protected by the device. Both currents and voltages are computed as true rms values. All EntelliGuard G Trip Units are equipped with an Ammeter. The full measurement package is offered in the GT-N and GT-H variants. The ammeter and other measurement options are only available when the trip unit is powered by the distribution system, the internal Trip Unit batteries or the external Test/battery pack. The full measurement package requires the use of a separately available 3 phase instrument transformer and Power Conditioner pack. STATUS To enter this option begin the process by pressing the UP or DOWN key until STATUS is selected on the screen. The Status option indicates the present status and settings of the trip unit and circuit breaker. EVENTS To enter this option begin the process by pressing the UP or DOWN key until EVENTS is selected on the screen. Pressing the NEXT or PREVIOUS key allows one to access events. Here a total of 10 events with data as event type and event magnitude are stored. The connection of a 24V DC auxiliary supply to the Trip Unit will expand this option to include a time stamp of each event. Tripping events as LT, ST, I GF, Overload Trip imminent (pre alarm) or any other, release or relay trip event are visualized with the associated levels. It is possible to clear this so called trip register locally. If the Trip Unit is equipped with this option, a history of up to 256 Tripping occurrences with data as event type and event magnitude are stored.

Intro A B C D E F X

Electronic Trip Units

SET UP METER STATUS EVENTS

SET UP METER STATUS EVENTS

SET UP METER STATUS EVENTS

SET UP METER STATUS EVENT LOG EVENTS

B.2

EntelliGuard G
Overload Protection LT-C and LTD

Overload (LT-C) Protection The EntelliGuard G Electronic Trip has an extremely accurate and easy to set overload or Long Time (LT-C) Protection. It is designed to pick up overloads that exceed 112% of the set value within two hours with a tolerance of 10%(1). The available 66 different current adjustments (see page B.4) result in an extremely broad setting range of 0.2 to 1 times the chosen breaker rating (In). The LT-C type is designed to be used in association with down- and upstream circuit breakers and has a so called I2t shape producing a curve form similar to standard industrial thermal magnetic protection devices. The Time-Current protection curve depicted here is drawn in cold state. A thermal model in the device corrects for the heating of the connected lines and equipment. This device continues to track cooling even when disconnected in Thermal Memory. The reconnection of power to over-heated lines and equipment thus being prevented. Thermal Memory tracks events after power disconnection for up to 12 minutes. In order to allow an accurate adjustment to the thermal properties of the protected equipment and to nely match the curve with those of Upstream & Downstream devices 22 LTD time bands are available. The table indicates the minimum delay time and maximum total interruption times for 3 frequently used reference points on the curve of each band. The graph portrays the LT behaviour for the time-current bands C-4, C- 8, C-13 & C-22.

Overload Protection

SET UP METER STATUS EVENTS

SET CURRENT 1000A Ie

LONG TIME pickup 0.5 BAND C5 Ir = 500A

EntelliGuard GT Electronic Trip Unit


10000 2h

- Time Current Curve LT- Protection Device C bands

Intro
1000

A B C
10

100

D E

Tripping Time In Seconds (s)

F
0,1 1,00 10,00 7,2 x
]

X
100,00

x Breaker Rating In

Overload Tripping times at indicated overload levels per selected LTD band, in Seconds x Ir Cmin C-2 C-3 C-4 Max. 7.8 23.4 46.7 62.3 1.5 Min. 4.0 12.0 24.0 32.0 Max. 1.3 3.86 7.73 10.3 3 Min. 0.80 2.41 4.82 6.43 Max. 0.21 0.62 1.24 1.66 7.2 Min. 0.13 0.40 0.81 1.07 Motor Protection Class to IEC 947-4 Standard on C-5 93.4 48.0 15.5 9.64 2.49 1.61 C-6 125 64.1 20.6 12.9 3.32 2.15 C-7 C-8 156 187 80.1 96.1 25.8 30.9 16.1 19.3 4.15 4.98 2.69 3.22 10b C-9 218 112 36.1 22.5 5.81 3.76 C-10 249 128 41.2 25.7 6.64 4.30 C-11 280 144 46.4 28.9 7.47 4.83 10 C-12 311 160 51.5 32.1 8.30 5.37 C-13 374 192 61.8 38.6 9.96 6.45 C-14 436 224 72.1 45.0 11.6 7.52 20 C-15 498 256 82.4 51.4 13.3 8.60 C-16 560 288 92.7 57.8 14.9 9.67 C-17 623 320 103 64.3 16.6 10.7 30 C-18 685 352 113 70.7 18.3 11.8 C-19 747 384 124 77.1 19.9 12.9 C-20 C-21 810 872 416 448 134 144 83.6 90.0 21.6 23.2 14.0 15.0 40 Cmax 934 480 155 96.4 24.9 16.1

GT-E

GT-S

GT-N

GT-H

(1) Meeting the requirements of IEC 90647-2 and IEC 90647-4

B.3

EntelliGuard G
Overload Protection LT-F and LTD

Intro A B C D

Overload (LT-F) Protection Optionally a second type of overload protection is available. Designed to pick up overloads that exceed 112% of the set value within two hours, with a tolerance of 10%(1), it has the same 66 different current adjustments as the standard type thus offering a extremely broad setting range of 0.2 to 1 times the chosen breaker rating. The Time-Current protection curve depicted here is drawn in cold state. A thermal model in the device corrects for the heating of the connected lines and equipment. This device continues to track cooling even when disconnected in Thermal Memory. The reconnection of power to over- heated lines and equipment thus being prevented. Thermal Memory tracks events after power disconnection for up to 12 minutes. The LT-F device is designed to be used in association with down- and upstream Fuses and produces a curve form similar to those of standard industrial fuses. A total of 22 LTD time bands are available, thus extending the total number of bands to 44. The table indicates the minimum delay time and maximum total interruption times for 3 frequently used reference points on the curve of each band. The graph portrays the LT behaviour for the time-current bands F-4, F-9, F-15 and F-22.

Electronic Trip Units

SET UP METER STATUS EVENTS

SET CURRENT 1000A Ie

LONG TIME pickup 0.5 BAND F2 Ir = 500A

EntelliGuard GT Electronic Trip Unit


10000 2h

- Time Current Curve LT- Protection Device - F Bands

1000

100

10

Tripping Time In Seconds (s)

E F X

0,1 1,00 10,00 100,00

x Breaker Rating In
]

Overload Tripping times at indicated overload levels per selected LTD band. in Seconds x Ir Max. Min. Max. 3 Min. Max. 7.2 Min. 1.5 Fmin 1.44 0.64 0.09 0.04 F-2 4.19 1.87 0.26 0.12 F-3 7.62 3.39 0.48 0.21 F-4 11.9 5.30 0.74 0.33 F-5 17.2 7.67 1.08 0.48 0.03 0.01 F-6 23.9 10.7 1.50 0.67 0.05 0.02 F-7 32.3 14.4 2.01 0.90 0.06 0.03 F-8 42.8 19.0 2.67 1.19 0.08 0.04 F-9 56 25 3.49 1.55 0.11 0.05 F-10 72 32 4.51 2.01 0.14 0.06 F-11 93 41 5.80 2.57 0.18 0.08 F-12 118 53 7.39 3.29 0.22 0.10 F-13 150 67 9.39 4.18 0.28 0.13 F-14 190 85 11.9 5.29 0.36 0.16 F-15 239 107 15.0 6.68 0.45 0.20 F-16 302 135 18.9 8.41 0.57 0.25 F-17 380 169 23.8 10.6 0.72 0.32 GT-H F-18 477 213 29.9 13.3 0.90 0.40 F-19 600 267 37.5 16.7 1.13 0.50 F-20 752 335 47.0 20.9 1.42 0. 63 F-21 942 419 58.9 26.2 1.78 0.79 Fmax 1153 514 72.1 32.1 2.18 1.03

Standard on

B.4

EntelliGuard G
Table indicating available Long Time settings
Per chosen Breaker Rating (In) 66 Current values (Ir) can be set
Breaker Multip. Rating 400 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 630 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 800 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 1000 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 1250 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 1600 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 Primary Setting Ie values in Amps Secundary Setting Ir values in Amps 390 385 380 180 371 366 361 171 351 347 342 162 332 327 323 153 312 308 304 144 293 289 285 135 273 270 266 126 254 250 247 117 234 231 228 108 215 212 209 99 195 193 190 90 615 610 605 280 584 580 575 266 554 549 545 252 523 519 514 238 492 488 484 224 461 458 454 210 431 427 424 196 400 397 393 182 369 366 363 168 338 336 333 154 308 305 303 140 784 776 768 350 745 737 730 333 706 698 691 315 666 660 653 298 627 621 614 280 588 582 576 263 549 543 538 245 510 504 499 228 470 466 461 210 431 427 422 193 392 388 384 175 980 970 960 450 931 922 912 428 882 873 864 405 833 825 816 383 784 776 768 360 735 728 720 338 686 679 672 315 637 631 624 293 588 582 576 270 539 534 528 248 490 485 480 225 1225 1210 1196 560 1164 1150 1136 532 1103 1089 1076 504 1041 1029 1017 476 980 968 957 448 919 908 897 420 858 847 837 392 796 787 777 364 735 726 718 336 674 666 658 308 613 605 598 280 1568 1552 1536 720 1490 1474 1459 684 1411 1397 1382 648 1333 1319 1306 612 1254 1242 1229 576 1176 1164 1152 540 1098 1086 1075 504 1019 1009 998 468 941 931 922 432 862 854 845 396 784 776 768 360 Breaker Multip. Rating 2000 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 2500 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 3200 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 4000 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 5000 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 6400 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 Primary Setting Ie values in Amps Secundary Setting Ir values in Amps 1960 1940 1920 900 1862 1843 1824 855 1764 1746 1728 810 1666 1649 1632 765 1568 1552 1536 720 1470 1455 1440 675 1372 1358 1344 630 1274 1261 1248 585 1176 1164 1152 540 1078 1067 1056 495 980 970 960 450 2450 2425 2400 1125 2328 2304 2280 1069 2205 2183 2160 1013 2083 2061 2040 956 1960 1940 1920 900 1838 1819 1800 844 1715 1698 1680 788 1593 1576 1560 731 1470 1455 1440 675 1348 1334 1320 619 1225 1213 1200 563 3136 3104 3072 1440 2979 2949 2918 1368 2822 2794 2765 1296 2666 2638 2611 1224 2509 2483 2458 1152 2352 2328 2304 1080 2195 2173 2150 1008 2038 2018 1997 936 1882 1862 1843 864 1725 1707 1690 792 1568 1552 1536 720 3920 3880 3840 1800 3724 3686 3648 1710 3528 3492 3456 1620 3332 3298 3264 1530 3136 3104 3072 1440 2940 2910 2880 1350 2744 2716 2688 1260 2548 2522 2496 1170 2352 2328 2304 1080 2156 2134 2112 990 1960 1940 1920 900 4900 4850 4800 2250 4655 4608 4560 2138 4410 4365 4320 2025 4165 4123 4080 1913 3920 3880 3840 1800 3675 3638 3600 1688 3430 3395 3360 1575 3185 3153 3120 1463 2940 2910 2880 1350 2695 2668 2640 1238 2450 2425 2400 1125 6272 6208 6144 2880 5958 5898 5837 2736 5645 5587 5530 2592 5331 5277 5222 2448 5018 4966 4915 2304 4704 4656 4608 2160 4390 4346 4301 2016 4077 4035 3994 1872 3763 3725 3686 1728 3450 3414 3379 1584 3136 3104 3072 1440

400 380 360 340 320 300 280 260 240 220 200 630 599 567 536 504 473 441 410 378 347 315 800 760 720 680 640 600 560 520 480 440 400 1000 950 900 850 800 750 700 650 600 550 500 1250 1188 1125 1063 1000 938 875 813 750 688 625 1600 1520 1440 1360 1280 1200 1120 1040 960 880 800

160 152 144 136 128 120 112 104 96 88 80 250 238 225 213 200 188 175 163 150 138 125 315 299 284 268 252 236 221 205 189 173 158 400 380 360 340 320 300 280 260 240 220 200 500 475 450 425 400 375 350 325 300 275 250 630 599 567 536 504 473 441 410 378 347 315

2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 2500 2375 2250 2125 2000 1875 1750 1625 1500 1375 1250 3200 3040 2880 2720 2560 2400 2240 2080 1920 1760 1600 4000 3800 3600 3400 3200 3000 2800 2600 2400 2200 2000 5000 4750 4500 4250 4000 3750 3500 3250 3000 2750 2500 6400 6080 5760 5440 5120 4800 4480 4160 3840 3520 3200

800 760 720 680 640 600 560 520 480 440 400 1000 950 900 850 800 750 700 650 600 550 500 1280 1216 1152 1088 1024 960 896 832 768 704 640 1600 1520 1440 1360 1280 1200 1120 1040 960 880 800 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 2560 2432 2304 2176 2048 1920 1792 1664 1536 1408 1280

Intro A B C D E F X

B.5

Overload Protection

EntelliGuard G
Short-circuit Protection ST and STDB

Electronic Trip Units

Overcurrent Protection Against Short-circuit: ST, STDB The EntelliGuard G Electronic Trip Unit and breaker combination can be equipped with a number of different Short-circuit protection devices each with their own distinctive properties and eld of application. The Timed Short-circuit Protection Device is designed to offer selectivity over a dened current range and offers a unique combination of multiple time bands and current settings. To allow selectivity with a wide range of different downstream devices whilst not unnecessarily sacricing clearing time, 17 different time bands are available. The device has an adjustment range of 1.5 to 12(1) (+-10%) times the chosen Long Time current value (Ir) in steps of 0.5 (pick up setting). The graph indicates 6 of the available 17 time bands across the full adjustment range. The table contains the minimum delay time and the maximum total interruption times for all time band settings.

SET UP METER STATUS EVENTS

SET CURRENT 1000A Ie

SHORT TIME PICKUP 3 x lr ST BAND 2 SLOPE OFF

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve ST- Protection Device I2t OFF- STDB bands

Intro A B C D

1 0,8 0,6 0,4

0,2

0,1

Tripping Time In Seconds (s)

E F X

0,01

0,001 1,00 10,00 100,00

x Breaker Rating In
]

Short Time tripping times at indicated levels per selected STDB band - I2t OFF, in Milliseconds (2) 1,5 x 10% 12 x 10% x Ir Tripping Non Tripping Tripping Non Tripping Min 90 30 90 30 2 100 40 100 40 3 110 50 110 50 4 120 60 120 60 5 170 110 170 110 6 190 130 190 130 7 240 180 240 180 GT-S 8 270 210 270 210 9 300 240 300 240 10 340 280 340 280 11 400 340 400 340 12 450 390 450 390 13 600 540 600 540 GT-H 14 700 640 700 640 15 800 740 800 740 16 900 840 900 840 Max 1000 940 1000 940

Standard on

GT-E

GT-N

(1) Is limited to lower values in certain cases, please refer to page B.11 (2) Timings in Red meet the requirements of the IEC 60479-1 and IEC 60364 standards at a frequency of 50 cycles

B.6

EntelliGuard G
Short-circuit Protection ST and I2T slope
EntelliGuard GT Electronic Trip Unit
10

- Time Current Curve - Time Current Curve ST- Protection Device ST- Protection Device

- STDB bands

I2t ON "low" K = 2 I2t -ON "low" K = 2 STDB bands

1 0,8 0,6 0,4

0,2

Timed Short-circuit (ST) Protection I2T Bands (slope) (3) The ST device can also be set to a I2T slope value. The available multiple I2t slopes are normally used to achieve selectivity with downstream fuses or to improve selectivity with downstream circuit breakers. The device has an adjustment range of 1.5 to 12 (1) (10%) times the chosen Long Time current value (Ir) in steps of 0.5 (pick up setting) and 17 time bands. The three graphs depict the available I2t slopes (Low, Med. or High) and their intersection with a selection of the available 17 time bands across the full adjustment range.

Electronic Trip Units Short-circuit Protection

0,1

Tripping Time In Seconds (s)

0,01

SET UP METER STATUS


10,00 100,00

SHORT TIME PICKUP 3 x lr ST BAND 2 SLOPE OFF

Intro A B

0,001 1,00

x Breaker Rating In
]

EVENTS

EntelliGuard GT Electronic Trip Unit


10

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve - Time Current Curve ST- Protection Device ST- Protection Device

- Time Current Curve - Time Current Curve ST- Protection Device ST- Protection Device

"med." K = 8 I2t -ON STDB Bands - STDB Bands

I2t ON "med." K = 8

I2t - ON "max." K = 18 STDB Bands - STDB Bands

I2t ON "max." K = 18

C D

1 0,8 0,6 0,4

1 0,8 0,6 0,4

E F X

0,2

0,2

0,1

0,1

Tripping Time In Seconds (s)

0,01

Tripping Time In Seconds (s)


10,00 100,00

0,01

0,001 1,00

0,001 1,00 10,00 100,00

x Breaker Rating In
]

x Breaker Rating In
]

Standard on

GT-E
2

GT-S

GT-N

GT-H

(3) When the LT Fuse band option is selected (22 F Bands) the I T slope functions of this device are disabled

B.7

EntelliGuard G
Short-circuit Protection; Instantaneous (I)

Instantaneous Short-circuit (I) Protection A user settable device that allows a high speed fault interruption at a pre-determined current level. This device can be used with the short time delayed (ST) Short-circuit protection device or as replacement thereof. The device has a current adjustment of 2 to 15 (10%) times the chosen Primary Current Value (Ie) in steps of 0.5 (pick up setting). On breakers with a rating of more than 4000A the maximum setting of 15 x is in some cases limited to a lower value due to the breaker current rating and its Short-circuit withstand value (see page B.11). The Instantaneous tripping system used in the EntelliGuard G Electronic Trip Unit has a unique programming feature that waits for the downstream device to trip before reacting to an overcurrent fault. This providing the user with a unique combination of Speed and Selectivity.
The graph indicates the Maximum interruption time and non tripping time across the full current setting band and the transition to the HSIOC protection device (see page B.11).

Electronic Trip Units

SET UP METER STATUS EVENTS

BREAKER RATING 1000A

INST PICKUP 2 x le

- Time Current Curve I - Protection Device

Intro A B C D

0,1

0,01

F X

Tripping Time in Seconds (S)

0,001 1,00 10,00 100,00

x Breaker Rating (In)

Standard on

GT-S

GT-N

GT-H

B.8

EntelliGuard G
Short-circuit Protection; Instantaneous (I)

Extended Range Instantaneous Protection Derived from, and based on the same principles as the standard Instantaneous protection but with and extended current adjustment range. This high-level instantaneous device extends the standard range from 2 - 15 to 2 - 30 (10%) times the chosen Primary Current Value (Ie). Until 15 x Ie in steps of 0.5 and for the extended setting (above 15 x Ie) in steps of 1. On breakers with a rating of more than 2000A the maximum setting of 30 x is in some cases limited to a lower value due to the breaker current rating and its Short-circuit withstand value (see page B.11). As with the standard Instantaneous tripping system the device has a unique programming feature that waits for the downstream device to trip before reacting to an overcurrent fault. This providing the user with a unique combination of Speed and Selectivity.
The graph indicates the Maximum interruption time and non tripping time across the full current setting band and the transition to the HSIOC protection device (see page B.11).

Short-circuit Protection

SET UP METER STATUS EVENTS

BREAKER RATING 1000A

INST PICKUP 16 x le

- Time Current Curve Ext. I - Protection Device

Intro A
0,1

B C D
0,01

Tripping Time in Seconds (S)

E F
0,001 1,00 10,00 100,00

x Breaker Rating (In)

Optional on

GT-S

GT-N

GT-H

B.9

EntelliGuard G
Short-circuit Protection temporary reduced I (RELT)

Intro A B C D

Temporary reduced setting of Instantaneous Short-circuit Device (RELT) When a Short-circuit event takes place, large amount of electrical energy is released that can be hazardous to users in the direct vicinity of such an occurrence. In order to limit the current levels during such events and to reduce their time span, the EntelliGuard G Electronic Trip Unit can be equipped with a temporary Reduced Instantaneous Device. This so called RELT device can be set via a hard contact input, communication signal to the Electronic Trip Unit or manually be switched on by using the LCD screen. When set, a signal output is provided (REL ON). On removal of the signal the Trip Unit reverts to its previous settings.(1) The RELT device can be adjusted from 1.5 to 15 (10%) times the Chosen Primary Current Value (Ie) in steps of 0.5 (pick up setting). The device will trip the breaker within 50 Milliseconds.
The graph indicates the Maximum interruption time and non tripping time across the full current setting band and the transition to the HSIOC protection device (see page B.11). Information on how to set this device can be found in IEEE standard 1548.

Electronic Trip Units

SET UP METER STATUS EVENTS

BREAKER RATING 1000A

RELT PICKUP 3 x le

- Time Current Curve RELT - Protection Device

0,1

(1) See section on Relay ouputs on Page B.17

0,01

F X

Tripping Time in Seconds (S)

0,001 1,00 10,00 100,00

x Breaker Rating (In)

Standard on

GT-N

GT-H

B.10

EntelliGuard G
Setting limitations of Short-circuit devices Short-circuit Protection: HSIOC, MCR
Setting Limitations of Short-circuit devices. To prevent damage to the EntelliGuard G breaker due to currents that exceed its design parameters, the maximum setting values of the ST & I devices are in some cases limited to a lower level. These values are indicated in the adjacent table.

Breaker Primary Rating setting In current Ie 5000A 5000A 6400A 6400A 2000A 2500A 3200A 4000A 5000A 6400A 2000A 2500A 3200A 4000A 5000A 6400A

50kA

Breaker Icw rating 65kA 85kA 100kA Maximum ST setting (x Ir) 10x 10x 10x 10x Maximum I or Ext. I setting (x Ie)(2) 24x 30x 30x 30x 25x 30x 30x 19x 25x 30x 15x 20x 24x 15x 19x 13x 15x

Short-circuit Protection

Breaker type is not available

HSIOC Protection device To prevent very high level Short-circuit currents causing damage to their electrical installation and their components EntelliGuard G Power Circuit Breaker are equipped with a HSIOC protection device. This high-level Short-circuit device is installed in all EntelliGuard G Breakers and is designed to trip the breaker at the specied Icw value of the device(3). The device interrupts and thus limits the duration of these high level Short-circuits to 40 Milliseconds. The HSIOC device is normally set at a value that is slightly higher than the specied 1 second Icw of the breaker in which it is installed. This to warranty selectivity at the specied 1 second level taking system tolerances into account(3).

Overview of installed HSIOC devices in Automatic types: Envelope 1 GG04S to GG20S GG04N to GG20N Envelope 2 GG25N to GG40N GG04E to GG20E GG25H to GG40H GG25M to GG40M Envelope 3 GG32G to GG40G GG40M to GG64M GG40L to GG64L

Set value (rms) 50000 A 65000 A 65000 A 85000 A 85000 A 85000 A 100000 A 100000 A 100000 A

Intro A B

Making Current (MCR) Protection device If a breaker is closed onto a Short-circuit current it is mandatory that the device interrupts before the electrical installation and its components incur any damage. An MCR device is present in all EntelliGuard G Power Circuit Breakers(4) specically designed to trip the breaker when closing onto a fault.

Overview of installed MCR devices in Automatic types: Envelope 1 GG04S to GG20S GG04N to GG20N GG04H to GG20H Envelope 2 GG25N to GG40N GG04E to GG20E GG25H to GG40H GG25M to GG40M Envelope 3 GG32G to GG40G GG40M to GG64M GG40L to GG64L

Set value (rms) 42000 A 50000 A 65000 A 65000 A 85000 A 85000 A 85000 A 100000 A 100000 A 100000 A

C D E F X

Overview of installed MCR devices in Non Automatic types: Envelope 1 GW04N to GW20N Envelope 2 GW04M to GW40M

Set value (rms) 65000 A 85000 A

(2) If the Short Time Device (ST) is turned OFF the highest instantaneous or extended instantaneous setting is reduced to 15 x Ie for all types 4000A and to 10 x Ie for the 5000 and 6400A types (3) If the breaker is not equipped with an Instantaneous protection device (I or Hi) or in cases where device is set to off the HSIOC device current threshold is automatically reduced by 10% (4) Only included in selected NON Automatic types

B.11

EntelliGuard G
Ground fault Protection: GF and GFD (Residual Type)

Intro A B C D E F X

Tripping Time In Seconds (s)

Ground Fault (GF) Protection To protect an installation or a part thereof against indirect contact, Protection Devices can be used to automatically disconnect the power supply when a fault to earth is detected. The HD384 installation standard requires that the mentioned device senses the fault and then interrupts the supply within a specied time frame. A Short-circuit device as an EntelliGuard G Power Circuit Breaker can be used to meet this requirement. However these Short-circuit Protection devices are normally set at values that are too high to detect normally occurring faults to Earth. The optionally available Ground Fault protection feature is specically designed to detect lower currents than a standard Short-circuit Device and operate by residually summing the current in the Phases and Neutral. When a fault to Earth creates an unbalance in the system the resulting Fault Current is detected by the device that produces an alarm signal or trips the associated Circuit breaker thus disconnecting the circuit. The EntelliGuard G Ground fault device has an adjustment range of 0.2 to 1(1) (+-15%) times the chosen breaker rating (In) and can be set in steps of 0.01 (pick up setting). To allow selectivity with other downstream Protection Devices there are 14 different time band settings available. The graph indicates a number of the available 14 time bands across the full adjustment range. The table contains the minimum delay time and the maximum total interruption times for all time band settings. The Ground fault device must monitor the current in all Phases and the Neutral. When a 3 pole device is used in a 4 wire (3phase + Neutral) system a 4th sensor must be placed in the Neutral(3). On use of a 4 pole EntelliGuard G breaker the sensor is already present in the Neutral pole.

Electronic Trip Units

SET UP METER STATUS EVENTS

BREAKER RATING 1000A

GF SUM PICKUP 0.3 x CT BAND 2 Slope OFF

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve GF- Protection Device I2t slope -OFF- GFDB Band

1 0,8 0,6 0,4

0,2

0,1

0,01 0,10 1,00 10,00

x Breaker Rating In
]

Ground Fault tripping times at indicated levels per selected GFDB band -I2t slope OFF, in Milliseconds (2) 0.2 x 10% 0.6 x 10% x Ir Tripping Non Tripping Tripping Non Tripping 1 110 50 110 50 2 120 60 120 60 3 140 80 140 80 4 170 110 170 110 5 190 130 190 130 6 240 180 240 180 7 270 210 270 210 8 340 280 340 280 9 400 340 400 340 10 450 390 450 390 11 600 540 600 540 12 700 640 700 640 13 800 740 800 740 14 900 840 900 840

(1) When an auxiliary supply is connected (24V DC) an extra setting range of 0.1 to 0.2 becomes available (2) Timings in Red meet the requirements of the IEC 60479-1 and IEC 60364 standards at a frequency of 50 cycles (3) Use a Rogowksi coil of the appropriate rating

B.12

EntelliGuard G
Ground fault Protection: GF and I2t slope
EntelliGuard GT Electronic Trip Unit - Time Current Curve - Time Current Curve Protection Device GF- GFProtection Device

10

I2t -'low' -ONGFDB Bands - GFDB Bands

I2t 'low' -ON-

1 0,8 0,6 0,4

Ground Fault Protection I2T Bands (slope) The GF device can also be set to a slope value. The available multiple I2t slopes are normally used to achieve selectivity with downstream fuses or to improve selectivity with downstream circuit breakers. The user has the possibility to choose a current adjustment of 0.2 to 1(1) times the chosen breaker rating (In) in steps of 0.01 (pick up setting) and one of 14 time bands. The three graphs depict the available I2t slopes (Set at positon Low, Med. or High) and their intersection with several of the available 14 time bands across the full adjustment range.

Ground/Fault Protection

0,2

0,1

Tripping Time In Seconds (s)

GF SUM PICKUP 0.3 x CT BAND 2 Slope Med.


]

Intro A B

0,01 0,10 1,00 10,00

x Breaker Rating In

EntelliGuard GT Electronic Trip Unit


10

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve - Time Current Curve Protection Device GF- GFProtection Device

- Time Current Curve - Time Current Curve Protection Device GF- GFProtection Device

-ONI2t - 'med' GFDB Bands - GFDB Bands

I t 'med' -ON-

I4t -max -ONGFDB Bands - GFDB Bands

I4t max -ON-

C D

1 0,8 0,6 0,4

1 0,8 0,6 0,4

E F X

0,2

0,2

0,1

0,1

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

0,01 0,10 1,00 10,00

0,01 0,10 1,00 10,00

x Breaker Rating In
]

x Breaker Rating In
]

Optional on

GT-E

GT-S

GT-N

GT-H

(1) When an auxiliary supply is connected (24V DC) an extra setting range of 0.1 to 0.2 becomes available

B.13

EntelliGuard G
Ground Fault Protection
Ground Return Method, Source Ground Return Method Restricted Earth Fault Applications (REF)

Electronic Trip Units

Ground Fault Protection (EGF) Source Ground Return method Optionally the EntelliGuard G Electronic Trip unit can be used with an alternative groundfault protection scheme in which the Neutral to Earth Current is measured by an Earthleakage Leg Sensor placed in the Neutral and Earth link of the system. This option requires the use of an auxiliary supply of 24VDC and the Electronic Trip Unit needs to be set to the option CT input. An Earth leg C needs to be placed in the near vicinity of the break(1) and an interposing CT needs to be mounted in breaker. When the sensor detects a fault current the EntelliGuard G trip trips the associated Circuit breaker thus disconnecting the circuit or optionally, produces an alarm signal. The EntelliGuard G device has an adjustment range of 0.2 to 1(2) (+-15%) times the chosen breaker rating (In) and can be set in steps of 0.01 (pick up setting). To allow selectivity with other downstream Protection Devices there are 14 different time band settings available and three I2T slope settings (Same setting data and curves apply as on the standard GF residual (sum) protection).
Optional on

SET UP METER STATUS EVENTS

BREAKER RATING 1000A

GF CT PICKUP 0.3 x CT BAND 2 Slope Med.

4 Wire system

4 Wire system

3 polig

4 polig

Intro A B C D E F X

= CT

= CT

GT-H

Dual Groundfault Protection (Residual or Sum & Source Ground Return or CT) The EntelliGuard G Electronic Trip Unit allows the user to combine the functionality of both the GF sum and GF CT systems thus creating a sophisticated Dual Ground Fault protection system. Based on the chosen breaker conguration and the network conguration in which the device is used devices as indicated in the adjacent table are required. A breaker mounted interposing Current Transformer (Int. CT) is required. This device is always supplied when a Earth Leg Transformer is ordered.

GF CT PICKUP 0.3 x CT BAND 2 Slope OFF

GF SUM PICKUP 0.3 x CT BAND 2 Slope Med.

Network 3 wire (3 phase) 4 wire (3 phase + Neutral)

EntelliGuard G nr. of Poles 3 3 3

GF Residual (SUM)

GF Source Return (CT) 4th CT Int. CT 4th CT Int. CT 4th CT Int. CT

GF sum PLUS GF CT 4th CT 4th CT Int. CT 4th Rg 4th CT

4th Rg

Optional on (1) Limited to 10 metres (2) When an auxiliary supply is connected (24V DC) an extra setting range of 0.1 to 0.2 becomes available

GT-H

B.14

EntelliGuard G
Zone Selective Interlock, Load Shedding and Trip Indication
Zone Selective Interlock Zone Selective Interlock Load Shedding Function Load Shedding Function Trip Reason Indicators (Event Logging) & Trip Trip Reason Indicators (Event Logging) & Trip Operation counter (Data acquisition package) Operation counter (Data acquisition package)
SET UP METER STATUS ZONE SEL/ INT. TLK EVENTS OFF

The EntelliGuard G Electronic Trip Unit uniquely offers this function on the following protection devices: Time delayed Short-circuit Protection (ST..STDB) Standard and Source Return Ground Fault protection (GF, GFDB) Instantaneous (Ii and Ihi) When a ZSI input is received the breaker changes its time band from the standard device setting to the ZSI setting. Both of these settings are user denable and can be set independently.

ST ZSI PICKUP 3 x lr ST BAND 2 Slope OFF

Zone selective Interlock (ZSI) This optional device has been specically designed to combine Speed and Selectivity. It requires one or two simple 2 core wire to connect the ZSI in and output between two or more Electronic Trip Units(1). If a breaker detects a fault it will send a signal to the upstream breaker to move its present time setting to another predened higher level. If the Short-circuit protection device has NO time setting GF ZSI band (Instantaneous), it simply gets a signal to wait another PICKUP 0.3 5 half cycles before tripping. x CT The breaker that originally BAND detects the faults only trips 2 Slope after transmitting the indicated Med. signals.

Ground Fault Protection

ZSI input sent

ZSI input sent

Fault occurs

Intro
GT-H

Optional on

GT-S

GT-N

Load shedding alarm output The load shedding device has been designed to allow the user to switch off NON priority loads before the LT functions trips the breaker due to an overload.
SET UP METER STATUS Alarm 1 ON EVENTS PICKUP 0.55 x ln

It can also be used to verify the current consumption in the circuit which the EntelliGuard G breaker protects. This to verify that the Alarm 2 current running in the circuit ON does not exceed a certain prePICKUP determined value. 0.7
x ln

load in one phase of the protected circuit exceeds a pre-dened value. The value can be set for two channels both having congurable ON and OFF current values adjustable from 0.5 to 1 x the breaker rating (In) in steps of 0.05. When the highest measured phase current exceeds the ON value set in one of the channels for longer than 60 seconds an output is provided to indicate that load shedding may prevent an overload tripping event. When the highest measured phase current drops below the OFF setting in one of the channels for longer than 60 seconds, the output is stopped(2). This function is part of the data acquisition and relaying package available on the GT-H trip unit type.
GT-H

A B C D E F X

The device monitors the current in the circuit and provides an alarm signal if the
Optional on

SET UP METER STATUS EVENTS

SET UP METER STATUS EVENTS Optional on

Trip Reason Indicators (event logging) Trip Operations counter The Electronic Trip Unit keeps track of data indicating why the associated breaker has tripped and on how may occurrences have taken place. Accessible under the EVENTS menu the Trip Reason Indicator keeps track of a maximum of 10 events that have caused the EntelliGuard G breaker to trip. The device stores the voltage, the phases involved, the current value, the reason of the trip and the trip number (see counter). When an auxiliary voltage is connected, the time and date of the event are also stored. The Trip Reason Indicator registers events for the following devices.

Overcurrent (LT, ST, I GF) Relaying Functions (se Page B13) Shunt or Undervoltage Release (If the associated contacts are connected via the trip unit) Accessible under the STATUS menu the Trip Operations Counter registers a maximum of 255 overcurrent faults with their reason (LT, ST, I or GFEF). The data can be viewed and reset through the STATUS menu Pickup Status option.

GT-E (1) See schematics on page E.4 (2) See section on Relay Outputs on page B.17

GT-S

GT-N

GT-H

B.15

EntelliGuard G
Measurement Functions and Power Supplies

SETUP METER METER

Ammeter An Ammeter is supplied with each EntelliGuard G Electronic Trip Unit. The current in each of the three phases and the Neutral can be viewed.
REAL POWER PHA/L1 700kW A Current APPR POWER PHB/L2 A PHA/L1 300A A PHA/L1 350A PHC/L3750kVA PHB/L2 320A PHB/L2 300A 480kVA PHC/L3 PHC/L3 320A 220kVA GT-E

Electronic Trip Units

STATUS Voltage EVENTS L1-N L1-N L1-N

The device has an accuracy of 2% when viewed at the nominal current of the breaker and an accuracy of 5% when viewed when the breaker is running at 50 - 85% of its full load.

Parameter Measured Current L1, L2, L3, N

Units A

Resolution 0000

Accuracy at 100% of breaker rating 2%

Standard on

GT-S

GT-N

GT-H

SETUP

Intro A B C D E F X

METER METER STATUS EVENTS

Full Measurement Package GT-N & GT-H type Electronic Trip Units have an advanced measurement facility that provides the user with a comprehensive overview of all relevant electrical parameters and their values. The adjacent table indicates the available parameters, the units used and their accuracy. When the option for display (Meter) is opened, a calculation is initiated that calculates each value based on a one second time frame. The device also calculates the sum of the used power in kWh, KVAh and KVArh as a total for all 3 phases. These values are kept and re-calculated every second. The Electronic Trip Unit has an option to allow these summations to be reset. Based on the same one second calculation method, a Power demand value is determined for Real (KW), Apparent (KVA) and Reactive (KVAR) power. If the Power supply has a neutral the values are calculated per phase and as a total of all three phases.

A Peak Power Demand calculation is available for Real Power(KW) only. Here the data is stored and when necessary renewed at a user denable pre-set time interval. When the new Peak Demand value exceeds the previous stored value the new value replaces the old in Memory. The Electronic Trip Unit has an option to reset this value.
Parameter Current Measured Units Resolution L1, L2, L3, N A 0000 0000 00 00 000.000 000.000 000.000 000.000 000.000 000.000 000.000 000.000 Accuracy at 100% of breaker rating 2% 2% 4% 1 cycle 4% 4% 4% 4% 4% 4% 4% 4%

Voltage L1, L2, L3 V Power Factor L1, L2, L3 % Frequency L1, L2, L3, N Hz Apparent Power L1, L2, L3 kVA Real Power L1, L2, L3 kW Reactive Power L1, L2, L3 KVAr Average Power demand Energy Peak Power Demand

L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3 L1, L2, L3

kVA kW KVAr KWh KW

Standard on

GT-N

GT-H

Power Conditioners and Auxiliary Power Supply To use the above mentioned comprehensive measurement facilities, it is necessary to track the 3phase and Neutral network voltages and to input these values into the Electronic Trip Unit. For this purpose the EntelliGuard G line includes a number of Power Conditioners that transform and condition a standard network power supply to a signal that the trip unit can safely use and read. When optioning the measurement facility for the 1st time, the Electronic Trip Unit will require the user to set the primary voltage values.
Accessory for

A number of advanced Trip Unit options require an auxiliary supply of 24V DC. A unit that transforms and conditions a standard network power supply to 24V DC is available for this purpose. The auxiliary supply also improves the speed of the trip unit setup function at low circuit loads (<20%) and when no standard power supply is present. A separately available Test Box Kit can also be used as a temporary power supply. This device has a battery pack and includes a 24 V DC auxiliary power supply.
GT-S GT-N GT-H

B.16

EntelliGuard G
Protective Relaying Functions; Relay and Trip Unit Inputs Wave Form Capture Option
SET UP METER STATUS EVENTS

Protective Relaying Functions The GT-H Electronic trip unit has ve protective relay functions. These can be switched ON or OFF and when active produce an alarm signal that is added to the Event Log and transmitted through the communication bus. Each relay function can be congured to trip the breaker or/and to send an alarm signal via a Relay Output
Adjustability 110% -115% of line voltage 1 to 15 seconds 30% - 85% of line voltage 1 to 15 seconds 10% -50% difference between highest & lowest phase when compared to average 1 to 15 seconds Line- to-Load OR Load to Line From 10 to 990kW 10% -50% difference between highest & lowest phase when compared to average 1 to 15 seconds Steps 1% 1sec 1% 1sec 1% 1sec 10kW 1% 1sec Accuracy 2% 0.1 sec. 2% 0.1 sec. 2% 0.1 sec. 2% 2% 0.1 sec. Trips Breaker ON or OFF ON or OFF ON or OFF ON or OFF ON or OFF

Advanced Features

Protective Relay
Overvoltage Overvoltage Delay Undervoltage Undervoltage Delay Voltage Unbalance Voltage Unbal. Delay Power Direction Reversal Power Reversal setting Current Unbalance Current Unbal. Delay

Standard on

GT-H

Intro A

SET UP METER STATUS EVENTS

Relay Outputs There are two programmable relay outputs available rated at 1A 24V AC or DC. These can be used for the Reduced Instantaneous Signal output or can be assigned to single functions or a group of functions to the protective relays functions mentioned above. Accessible under the SETUP the outputs are wired out through the secondary terminals of the breaker as indicated on page E4. The following settings are possible.

Function GF Alarm Over-current trip (GF, INST, LT, ST) Reduced Instantaneous Active Protective Relays Current Alarm 1 Current Alarm 2 Health status output number

Group Assigned to group 1 Assigned to group 2 Assigned to group 7 Assigned to group 4 Assigned to group 4 Assigned to group 5 Assigned to group 6

B C D E F X

Standard on

GT-N

GT-H

SET UP METER STATUS EVENTS

Electronic Trip unit INPUTS There is a total of 2 programmable inputs available. These can be used to switch the Reduced Instantaneous ON, or can be used as input to trip the breaker. The inputs are suitable for voltages up to 24V AC or 30V DC. Accessible under the SETUP the outputs are wired out through the secondary terminals of the breaker as indicated on page E4.

Standard on

GT-N

GT-H

SET UP METER STATUS EVENTS

Wave Form Capture option When a fault has taken place, it can be of importance to visualize the event. The Wave form Capture option included in the GT-H type Electronic Trip Unit can track and visualize any fault event. The device tracks 8 cycles, 4 before and 4 after the event with resolution of 48 samples per cycle at 50Hz and stores the results in memory. It registers

events in all three phases and the Neutral. After the event, the waveform event is stored and can be accessed by using the waveform client module of the Enervitsa software. When the upload into this software is complete, the Trip Unit will reset this function and be available to register the next event.

Standard on

GT-H

B.17

EntelliGuard G
Communications Neutral protection, Reset Choice Rating Plug and Test Kit
SET UP METER

Electronic Trip Units

STATUS EVENTS

Communications A number of the GT Electronic trip unit types can be optioned to allow the Breaker & Trip Unit combination to communicate data bi-directionally through Modbus or Probus. The communication option needs a 24 V auxiliary voltage input capable of supplying 90mA for the Modbus option and 240mA for the Probus option. All Trip Unit parameters can be programmed through communications (or the Keyboard). These parameters include over current settings, protective relay functions, alarms settings etc. The

Electronic trip unit has a locking password that prevents an unauthorized change of settings by the keypad or over communications. The Electronic Trip Unit is fully compliant with the Modbus Protocol and 2 wire Modbus 485 is supported. The device is congured to stay on one xed baud rate or, to cycle through the baud rates until communications are established. The link Host can operate at 300, 600, 1200, 2400, 4800, 9600 and 19200-baud rates. Probus DP over RS485 type II and Multidrop networks is supported.

Optional on

GT-S

GT-N

GT-H

Intro A B C D E F X

SET UP METER STATUS EVENTS

Neutral Protection When inserted into a 4 pole breaker the EntelliGuard G Electronic Trip Unit senses that the breaker in which the device is installed has a Neutral Pole. Via the set Up menu, a Neutral Setting option then becomes available in which the LT, ST and I protection device can be jointly set to one of
GT-E GT-S

the following values: 0%, 50% or 100%. x the values set for the phase protection device.

Standard on

GT-N

GT-H

Reset Choice Function When a fault has occurred the Trip Unit trips the associated breaker. It is then deemed normal installation practise to verify the reason of the fault before reconnecting power by resetting and switching the breaker on. The advanced options included in the EntelliGuard G Trip Unit provide the user with the fault reason, magnitude and location, thus allowing the user to easily establish the
Standard on GT-E GT-S

required corrective actions. To follow this procedure Trip Unit reset function should be set to MANUAL. However, in some cases it is required that the breaker resets itself automatically. If this functionality is required, the reset function should be set to AUTOMATIC. A selector switch on the Trip Unit front face allows the user this choice.

GT-N

GT-H

Full Range Rating Plug Each EntelliGuard G Electronic Trip Unit must be equipped with a separately available Rating Plug to allow it to function correctly. The Full Range Rating Plug is plugged in to a jack on the trip Unit Front Face. When this device is not installed, the Trip Unit

will revert to its minimum setting, which has as value of 16-18% of the breaker rating In.

Accessory for

GT-E

GT-S

GT-N

GT-H

Test Kit To verify that the Electronic Trip Unit is interfacing correctly with the Breaker and to establish if the circuitry in the Trip Unit is functioning correctly, a test kit is available. The device has a battery pack

and a 24V auxiliary supply to allow its use in a secondary function as power supply of the Trip unit when no network power supply is available. The device can be plugged into a jack on the trip Unit Front face.

Accessory for

GT-E

GT-S

GT-N

GT-H

B.18

EntelliGuard G
Overview of GT Electronic Trip Unit Functionality
GT-E X X X X X X X X X X X X X X X X O O O O O O X X X X X O O GT-S X X X X X X X X X X X X X X X X X X X O O O O X O O O O O O X X X X X O O O O O GT-N X X X X X X X X X X X X X X X X X X X O O O O X X X X X O O O O O O X X X X X X X X X X X X X X O X O O O O GT-H X X X X X X X X X X X X X X X X X X X X X X O O O O X X X X X O O O O O O O O O O X X X X X X X X X X X X X X X X X X X X X X X O O O X X O O O O Remarks --------

Short Time Long Time or Overload Setting Short-circuit CurCurrent Protection Interface rent Protection

LCD Screen allowing access to 4 distinct Menus Touch pad adjustments Multilingual Adjustable Manual or Automatic RESET option 6 primary current settings with FULL RANGE Rating Plug 1, 0.975, 0.9625, 0.95, 0.45 & 0.4 x Breaker rating In 11 secondary current settings Ir 1, 0.95, 0.9, 0.85, 0.8, 0.75, 0.7, 0.65, 0.6, 0.55, 0.5 x Primary setting Ie Resulting setting Range 0.2 to 1 with 66 set points 22 Thermal Protection (C type) time bands available Ranging from class 0.5 to 40 (bands at 7.2 x Ir) 22 F type (fuse) time bands available Neutral Protection 0-50%-63%-100% Cooling function and Thermal memory Setting RANGE from 1.5 to 12 x Ir (LT setting) Steps of 0.5 (A total of 22 settings) Possibility to Switch OFF 17 Time delay settings (STDB) ranging from 30 to 940 Milliseconds delay setting result in a 90 to 1000 Milliseconds Clearing time Clearance times to IEC 40979-1 and IEC 60364 3 It Protection time bands available Ii Setting RANGE from 2 to 15 x Ie (Primary Setting) Steps of 0.5 (A total of 28 settings) Possibility to Switch OFF Selective Execution Fixed Instantaneous or HSIOC protection Ihi Setting RANGE from 2 to 30 x Ie (Primary Setting) 2-15 Steps of 0.5; 15-30x steps of 1 (A total of 43 settings) Possibility to Switch OFF Selective Execution Fixed Instantaneous or HSIOC protection Ii Setting RANGE from 1.5 to 15 x Ie (Primary Setting) Steps of 0.5 (A total of 29 settings) Possibility to Switch OFF Remote and Local ON and OFF with position indication signal Setting RANGE from 0.1 to 1 x In (Breaker Rating) (1) Steps of 0.01 (A total of 92 settings) Possibility to Switch OFF 14 Time delay settings (GFDB) ranging from 50 to 840 Milliseconds delay setting resulting in a 110 to 900 Milliseconds Clearing time Clearance times to IEC 40979-1 and IEC 60364 3 It Protection time bands available Residual Principle Source Ground Return Principle UEF, REF and SEF applications possible Combinations of UEF, REF and SEF applications possible Current (L1, L2, L3, N) Voltage (L1, L2, L3) Energy (kWh) Total Real Real Power (L1, L2, L3, total) Apparent Power (L1, L2, L3, total) Reactive Power (L1, L2, L3, Total) Total Power (L1, L2, L3, total) Power (kW) Peak (total) Demand Power (kW) (total) Frequency (L1, L2, L3) Voltage Unbalance Undervoltage Overvoltage Current Unbalance Power Reversal Trip Target (trip reason indication) Trip Info (Magnitude / Phase) Waveform capture Trip Counter Event Logger (trip events) Relay based on current level (load shedding) Good & Bad Health Indicator Watchdog Zone Selective Interlock on ST, GF and I Shunt trip status input (2 inputs) UVR trip status input (2 inputs) General relay outputs (2) and electronic inputs (2) Communication 2 way Modbus Probus 24V DC Auxiliary Power supply Text kit with Power support function

Function Overview

-------------------------------N N N -C C C C C C C C -N N N N N --N ---------N N N ---

Instantaneous Short-circuit Current Protection

Extended range

Standard

Intro A B C D E F X

Key X - Present; O = Optional, - = Not Possible Remarks N indicates that a 24V auxiliary power supply is required, a C indicates the need of a Power Conditioner (1) Without a 24V auxiliary power supply, the lowest setting is 0.2

Other

Data Acquisition & Protective Diagnostics Relaying

Measurement package

Ground or Earth Fault Protection

Reduced

B.19

EntelliGuard G
Time Current Curves (cold state)
LT Protection Device
EntelliGuard GT Electronic Trip Unit
10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

Electronic Trip Units

- Time Current Curve LT- Protection Device - Band C-06 - Band C-11 - Band C-16 - Band C-22

- Time Current Curve LT- Protection Device - Band C-02 - Band C-07 - Band C-12 - Band C-17

1000

1000

100

100

ST protection - OFF 10 I protection set to 15 x Ie(1) 10

ST protection - OFF I protection set to 15 x Ie(1)

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

Intro A B C D

0,1 1,00 10,00 7,2 x 100,00

0,1 1,00 10,00 7,2 x 100,00

x Breaker Rating In

x Breaker Rating In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

- Time Current Curve LT- Protection Device - Band C-03 - Band C-08 - Band C-13 - Band C-19

- Time Current Curve LT- Protection Device - Band C-04 - Band C-09 - Band C-14 - Band C-20

1000

1000

E F X
10 100 100

ST protection - OFF I protection set to 15 x Ie(1) 10

ST protection - OFF I protection set to 15 x Ie(1)

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)


10,00 7,2 x 100,00

0,1 1,00

0,1 1,00 10,00 7,2 x 100,00

x Breaker Rating In

x Breaker Rating In

B.20

EntelliGuard G
Time Current Curves (cold state)
LT Protection Device
EntelliGuard GT Electronic Trip Unit
10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

- Time Current Curve LT- Protection Device - Band C-05 - Band C-10 - Band C-15 - Band C-21

- Time Current Curve LT- Protection Device - Band C-01 - Band C-18

Time Current Curves

1000

1000

100

100

ST protection - OFF 10 I protection set to 15 x Ie(1) 10

ST protection - OFF I protection set to 15 x Ie(1)

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

Intro
1

A
0,1 1,00 10,00 7,2 x 100,00

0,1 1,00 10,00 7,2 x 100,00

B C D E

x Breaker Rating In

x Breaker Rating In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

1000

- Time Current Curve LT- Protection Device - Band F-01 - Band F-05 - Band F-09 - Band F-13 - Band F-17 - Band F-21

1000

- Time Current Curve LT- Protection Device - Band F-02 - Band F-06 - Band F-10 - Band F-14 - Band F-18 - Band F-22

100

100

F X

10

10

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

ST protection - OFF I protection set to 15 x Ie(1)

ST protection - OFF I protection set to 15 x Ie(1)

0,1 1,00 10,00 100,00

0,1 1,00 10,00 100,00

x Breaker Rating In

x Breaker Rating In

B.21

EntelliGuard G
Time Current Curves (cold state)
LT & ST Protection Device
EntelliGuard GT Electronic Trip Unit
10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

EntelliGuard GT Electronic Trip Unit


10000 2h
LT set at Breaker Rating In Setting Range Ie = 0,975, 0,9625, 0,95, 0,45 or 0,4 x In Ir = 0,5 to 1 x Ie in steps of 0,25 Total Setting Range 0,2 - 1 x In

Electronic Trip Units

1000

- Time Current Curve LT- Protection Device - Band F-03 - Band F-07 - Band F-12 - Band F-15 - Band F-19

1000

- Time Current Curve LT- Protection Device - Band F-04 - Band F-08 - Band F-13 - Band F-16 - Band F-20

100

100

10

10

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

Intro A B C D E F X

ST protection - OFF I protection set to 15 x Ie(1)

ST protection - OFF I protection set to 15 x Ie(1)

0,1 1,00 10,00 100,00

0,1 1,00 10,00 100,00

x Breaker Rating In

x Breaker Rating In

EntelliGuard GT Electronic Trip Unit


10

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve ST- Protection Device I t -OFFBand STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17
2

- Time Current Curve ST- Protection Device I2t -OFFBand STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 19 Band STDB 12 Band STDB 14 Band STDB 16

LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

1 0,8 0,6 0,4

17 15 13 11 9

17 15 13 11 9 7 5 3 1

1 0,8 0,6 0,4

16 14 12 10 8

16 14 12 10 8 6

0,2

7 5

0,2
6

4 2

0,1

0,1
4

3 2 1

Green line = Full Clearing time Red Line = Non Tripping time

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

0,01

0,01

I protection set to 15 x Ie(1)

I protection set to 15 x Ie(1)

0,001 1,00 10,00 100,00

0,001 1,00 10,00 100,00

x Breaker Rating In

x Breaker Rating In

B.22

EntelliGuard G
Time Current Curves (cold state)
ST Protection Device
EntelliGuard GT Electronic Trip Unit
10

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve ST- Protection Device I2t ON "low" Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17

- Time Current Curve ST- Protection Device I2t ON "low" Band STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16

LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

Time Current Curves

1 0,8 0,6 0,4

17 15 13

17 15 13 11

1 0,8 0,6 0,4

16 14 12 10 8

16 14 12 10 8 6 4 2

11 9

9 7 5 3 1

0,2

7 5

0,2
6

0,1

0,1
4

3 2 1

Green line = Full Clearing time Red Line = Non Tripping time

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

0,01

Tripping Time In Seconds (s)

0,01

Intro
I protection set to 15 x Ie(1)

I protection set to 15 x Ie(1)

A
0,001 1,00 10,00 100,00

0,001 1,00 10,00 100,00

B C D E F X

x Breaker Rating In

x Breaker Rating In

EntelliGuard GT Electronic Trip Unit


10
LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

EntelliGuard GT Electronic Trip Unit


10
LT set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

- Time Current Curve ST- Protection Device I2t ON "med." Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17

- Time Current Curve ST- Protection Device I2t ON "med." Band STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16

1 0,8 0,6 0,4

17 15 13

17 15 13 11

1 0,8 0,6 0,4

16 14 12 10 8

16 14 12 10 8 6 4 2

11 9

9 7 5 3 1

0,2

7 5

0,2
6

0,1

0,1
4 2

3 1

Green line = Full Clearing time Red Line = Non Tripping time

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

0,01

Tripping Time In Seconds (s)

0,01

I protection set to 15 x Ie(1)

I protection set to 15 x Ie(1)

0,001 1,00 10,00 100,00

0,001 1,00 10,00 100,00

x Breaker Rating In

x Breaker Rating In

B.23

EntelliGuard G
Time Current Curves (cold state)
ST and I Protection Device
EntelliGuard GT Electronic Trip Unit
10
ST set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

EntelliGuard GT Electronic Trip Unit


10
ST set at Breaker Rating In Setting Range 1,5 to 12 x Ir in steps of 0,5

- Time Current Curve ST- Protection Device I2t ON "max." Band STDB 01 Band STDB 03 Band STDB 05 Band STDB 07 Band STDB 09 Band STDB 11 Band STDB 13 Band STDB 15 Band STDB 17

- Time Current Curve ST- Protection Device I2t ON "max." Band STDB 02 Band STDB 04 Band STDB 06 Band STDB 08 Band STDB 10 Band STDB 12 Band STDB 14 Band STDB 16

Electronic Trip Units

1 0,8 0,6 0,4

17 15 13

17 15 13 11

1 0,8 0,6 0,4

16 14 12 10 8

16 14 12 10 8 6 4 2 4 2

11 9

9 7 5 3 1 3 1

0,2

7 5

0,2
6

0,1

0,1

Green line = Full Clearing time Red Line = Non Tripping time

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

Intro A B C D E

0,01

0,01

I protection set to 15 x Ie(1)

I protection set to 15 x Ie(1)

0,001 1,00 10,00 100,00

0,001 1,00 10,00 100,00

x Breaker Rating In

x Breaker Rating In

1
LT set Breaker Rating In HI Setting Range 2 to 15 x Ie in steps of 0,5

- Time Current Curve I - Protection Device RELT - Protection Device

1
LT set Breaker Rating In HI Setting Range 2 to 30 x Ie in steps of 0,5 i f

- Time Current Curve Ext.I - protection device RELT - Protection Device

0,1

HSIOC device

0,1

HSIOC device

F X
0,01 Green line = Full Clearing time Red Line = Non Tripping time Green line = Full Clearing time Red Line = Non Tripping time

0,01

Tripping Time in Seconds (S)

Tripping Time in Seconds (S)

LT set Breaker Rating In RELT Setting Range 1,5 to 15 x Ie in steps of 0,5

LT protection set Breaker Rating In RELT Setting Range 1,5 to 15 x Ie in steps of 0,5

0,001 1,00 10,00 100,00

0,001 1,00 10,00 100,00

x Breaker Rating (In)

x Breaker Rating (In)

B.24

EntelliGuard G
Time Current Curves (cold state)
HSIOC & GF Protection Device

I Setting On set at 15kA

- Time Current Curve HSIOC - Protection Device I - Present & ON

ST Set at 12,5kA STDB 1

- Time Current Curve HSIOC - Protection Device I - NOT PRESENT OR OFF ON

Time Current Curves

100kA 85kA 65kA 0,1 0,1 50kA

Green line = Full Clearing time Red Line = Non Tripping time

Green line = Full Clearing time Red Line = Non Tripping time 0,01 0,01

Tripping Time in Seconds (S)

50kA 65kA 85kA 100kA

Tripping Time in Seconds (S)

Intro A
0,001 1000 10000 100000 1000000

0,001 1000 10000 100000 1000000

B C D E F X

Amps

Amps

EntelliGuard GT Electronic Trip Unit


10

EntelliGuard GT Electronic Trip Unit


10

- Time Current Curve GF- Protection Device I2t -OFFBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13

- Time Current Curve GF- Protection Device I2t -OFFBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 08 Band GFDB 10 Band GFDB 12 Band GFDB 14

LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

1 0,8 0,6 0,4


13 11 9 9 7 7 5 13 11

1 0,8

14 12

14 12

0,6
10

0,4

10 8 8 6 6

0,2

0,2
4

0,1

0,1 Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

0,01 0,10 1,00 10,00

0,01 0,10 1,00 10,00

x Breaker Rating In

x Breaker Rating In

B.25

EntelliGuard G
Time Current Curves (cold state)
GF Protection Device
EntelliGuard GT Electronic Trip Unit
10
LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

EntelliGuard GT Electronic Trip Unit


10
LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

- Time Current Curve GF- Protection Device I2t 'low' -ONBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13

- Time Current Curve GF- Protection Device I2t 'low' -ONBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 07 Band GFDB 10 Band GFDB 12 Band GFDB 14

Electronic Trip Units

1 0,8 0,6 0,4


13 11 9 9 7 7 5 13

1 0,8
11

14 12

14 12

0,6
10

0,4

10 8 8 6 6 4

0,2

0,2
4

0,1

0,1 Green line = Full Clearing time Red Line = Non Tripping time
1 2

Tripping Time In Seconds (s)

A B C D E

0,01 0,10 1,00 10,00

Tripping Time In Seconds (s)

Intro

Green line = Full Clearing time Red Line = Non Tripping time

0,01 0,10 1,00 10,00

x Breaker Rating In

x Breaker Rating In

EntelliGuard GT Electronic Trip Unit


10
LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

EntelliGuard GT Electronic Trip Unit


10
LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

- Time Current Curve GF- Protection Device I2t 'med' -ONBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13

- Time Current Curve GF- Protection Device I2t ''med' -ONBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 07 Band GFDB 10 Band GFDB 12 Band GFDB 14

1
13 11 9 9 7 7 5 13 11

14 12

14 12

F X

0,8 0,6 0,4

0,8 0,6

10

0,4

10 8 8 6 6 4

0,2

0,2
4

0,1 Green line = Full Clearing time Red Line = Non Tripping time
1

0,1
2

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

0,01 0,10 1,00 10,00

Tripping Time In Seconds (s)

0,01 0,10 1,00 10,00

x Breaker Rating In

x Breaker Rating In

B.26

EntelliGuard G
Time Current Curves and Terminology
Time Current Curves (cold state)
Terminology
EntelliGuard GT Electronic Trip Unit
10
LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01 i f

EntelliGuard GT Electronic Trip Unit


10
LT set at Breaker Rating In Setting Range 0,2 to 1 x In in steps of 0,01

- Time Current Curve GF- Protection Device I2t max.-ONBand GFDB 01 Band GFDB 03 Band GFDB 05 Band GFDB 07 Band GFDB 09 Band GFDB 11 Band GFDB 13

- Time Current Curve GF- Protection Device I2t max.-ONBand GFDB 02 Band GFDB 04 Band GFDB 06 Band GFDB 07 Band GFDB 10 Band GFDB 12 Band GFDB 14

1 0,8 0,6 0,4


13 11 9 9 7 7 5 13 11

1 0,8

14 12

14 12

0,6
10

0,4

10 8 8 6 6 4

0,2

0,2
3 4

0,1 Green line = Full Clearing time Red Line = Non Tripping time
1

0,1
2

Green line = Full Clearing time Red Line = Non Tripping time

Tripping Time In Seconds (s)

Tripping Time In Seconds (s)

Intro A

0,01 0,10 1,00 10,00

0,01 0,10 1,00 10,00

B C D E F X

x Breaker Rating In

x Breaker Rating In

Denonimation In Ie Iu LT ST I GF EF Ir Ist Ii Ig LTDB STDB I2t x LT x Ie x In x CT RELT MCR HSIOC

Description Current rating of Breaker Primary Current setting Maximum Breaker User current (see section D) Long Time or Overload protection Short Time or Timed Short-circuit Current setting Standard or Extended Instantaneous setting Groundfault Earthfault LT or overload Current setting ST or Timed Short-circuit Current setting Instantaneous Short-circuit Current setting Ground, or Earthfault Current setting LT or overload time delay band (C = breaker type, F = fuse type) ST or Short-circuit time delay band 'Slope' setting on ST or GF device Multiple of LT or overload Current setting Multiple of ST or Timed Short-circuit Current setting Multiple of Breaker Current rating Multiple of installed sensor rating (In IEC EntelliGuard G types =In) Reduced Instantaneous Making Current Release Hi set Instantaneous protection

B.27

EntelliGuard G
Time Current Curves (cold state)
Example of Full Time Current Curve Time Current Curve The EntelliGuard G Electronic trip unit has many sophisticated setting features and an extremely broad setting range. On request we can provide complete Time Current Curves covering all installed protection devices. The curves can be produced for any current setting within the range of the installed protection devices, for one or for a combination of two breakers. Please contact your local GE Sales Ofce for more information.

Electronic Trip Units

EntelliGuard GT Electronic Trip Unit


10000 2h

Time Current Curve Breaker In =2500A


LT- Protection Device Set at Ie = 2400A Ir at 0.9 =2160A Band C-10 ST- Protection Device Set at 6 x Ir of 2160A (Ist =12960A) Band STDB 10 I2t ON & Max. I- Protection Device Set at 12 x Ie of 2400A Ii = 28800A GF- Protection Device Set at 0.6 x Ie of 2500A (Ig = 1500A ) Band GFDB 6 I2t ON & M d

1000

Intro A B C D
1 10 GF Band 100

LT Band

ST Band

E F X
Tripping Time In Seconds (s)
0,1 I Band

0,01 HSIOC Band

0,001

Green & Light Blue Linel = Full Clearing time Red Line & Dark Blue Line = Non Tripping time

1000

10000 7,2 x

100000

x Current in Amps

B.28

EntelliGuard G

Breaker Accessories C.2 C.3 C.4 C.5 C.6 C.7 C.8 C.9 C.10 C.11 Breaker Use & Operation Electrical Operation of Breaker (Motor Operator) Shunt & Undervoltage Releases; Time Delay Module for Undervoltage Release Interlock Devices, Indication Contacts and Number of devices Auxiliary Contacts Bell Alarm, Cassette position, Spring charged and Ready to Close indication contacts Mechanical Interlocking of Multiple Breakers Locking previsions for Breaker and Cassette Door-Interlock systems; Mis insertion device Installation Accessories Earthing device (maintenance accessory) Spare Parts

The breaker Order Codes Electronic Trip Units Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

Intro A B C D E F X

C.1

EntelliGuard G
Breaker Use & Operation
A Power Circuit Breaker EntelliGuard G is operated by a stored energy mechanism that can be charged either manually or electrically. To charge manually a handle 1 is used to load the springs in the mechanism, 10 pumping movements being required. During charging a spring status indicator 2 clearly indicates if the breaker is CHARGED (Red), Indicated Breaker is of a Fixed CHARGING (Yellow), or Pattern and equipped with Trip Unit DIS-CHARGED (Green). After charging is complete, the ready to close indicator 3 indicates that the device can be turned ON and OFF (1) by the ON/ OFF buttons ( 4 & 5 ) on the breaker front facia. A padlocking mechanism 6 is present for up to three locks that can prevent un-authorized pushbutton operation. An electrical charging mechanism negates the need for loading the springs manually and allows remotely located pushbuttons to be used to switch ON & OFF (see page C.3). The contact position indicator 7 on the Breaker front provides the user with the correct status of the breaker be it OFF or ON. This indicator is linked to the mechanism and contact system in a manner that allows the device to be used as a Disconnector and to meet the Positive Contact Indication requirements. The Breaker Mechanism is of the trip free type and has an integrated anti-pumping system. The front facia also includes room for an optional key interlock device 8 that prevents the breaker from being closed if the key is not inserted and the keylock turned to free. The interlock device allows a maximum of 4 keylocks to be placed. The breaker can be equipped with up to four factory or eldMountable releases, 1 x closing coil and a combination of shunt and undervoltage releases being possible. The presence of these releases is made visible on the facia by the use of 4 indicator windows 9 . EntelliGuard G Power Circuit Breakers are available in two patterns, Fixed and Draw out. A Fixed device is bolted to a substructure or wall and the power connections are directly xed to the breaker. A draw out device has a cassette that is mounted and connected separately. A xed breaker requires the connection and xation to be removed to replace the breaker. A breaker in draw out pattern is supplied as a moving portion, that easily slides in and out of the separately xed and connected cassette. Each standard device is supplied with 3 NO and 3 NC potential free auxiliary contacts. A IP31 front panel with door escutcheon seal and a IP20 terminal strip or plug 10 with 39 connection points to wire out accessories.

Intro A B

Breaker Accessories

Draw out Pattern Cassette

C D E F X

To dismount a EntelliGuard G in the Fixed pattern it is required that the power supply is turned off and the connections are removed. A breaker in the Draw out pattern can be quickly and efciently removed from the system without disconnecting the Power Supply or removing the connections. The Draw out system allows easy and simple access to the breaker and its components and enables the user to fully disconnect the power from the installation for maintenance purposes. Access to the breaker being required for periodic checks and some very limited maintenance allowing the device to be used over its full life span. The cassette 1 is mounted and connected separately and the EntelliGuard G breaker is supplied as a moving portion that is easily inserted into the cassette. A racking handle 2 is stored within an aperture 3 in the cassette. After removing and unfolding the racking handle and disengaging the blocking mechanism 4 , the handle can be inserted into the racking aperture 5 .

By rotating the racking handle clockwise to move the moving portion inwards (connect) and anti-clockwise to move outwards, (disconnect) the breaker can be racked into one of three positions: Breaker and cassette are fully operational all contacts are connected. TEST The maincontacts are not connected. The Auxiliary contacts are connected. DISCONNECTED The main and auxilary contacts are not connected. The breaker is still inside the cassette. To remove the breaker from the cassette, the racking handle must be removed from the racking aperature. A Position indicator 6 provides a positive mechanical indication of the indicated Connected, Test and Disconnected positions. Each EntelliGuard G cassette has integrated Safety Shutters 7 that automatically isolate the user from live parts when the moving portion is in disconnect or test position. Multiple accessories as carriage position switches, mechanical interlocks, a miss-insertion device, IP54 front protection covers and key lock devices are available (please refer to the relevant sections in this chapter). Each standard cassette is supplied with standard main connections, racking handle, safety shutters and a IP20 terminal socket system with 39 connection points to wire out accessories. CONNECTED

(1) Independent of the breaker position (tripped or ON) the device always provides sufcient energy to switch the breaker OFF

C.2

EntelliGuard G
Electrical Operation of Breaker
Electrical Charging mechanism (motor) In order to charge the stored energy mechanism electrically a motor mechanism is available. The design allows factory or eld mounting and is available for the full range of EntelliGuard G breakers. It is easily tted with just three bolts. When the circuit breaker is opened, the mechanism automatically recharges the springs and prepares the breaker for an almost instantaneous reclosure should the need arise. High speed recharging ensures that the springs are fully charged within four seconds. A Spring Charged contact that indicates the status of this device is always present. A 2nd ready to close contact is available that indicates that the springs have been recharged and that the breaker can be closed. The device is available in multiple AC & DC voltages and can be used in a operating frequency of up to two operations per minute. it has a life span equivelant to that of the breaker without maintenance. To switch the EntelliGuard G Breaker ON & OFF remotely a Closing Coil and Shunt Release is also necessary. Closing Coil To switch the Power Circuit Breaker ON remotely a closing coil is available that when energized releases the spring charged closing mechanism. The device is available as a factory mounted component or as a eld mountable device. It is an extremely easy-to-t, clip-on unit, with simple plug-in connectors. The coils have a life span equivalent to that of the full breaker life span.

Breaker Use and Operation

Command Closing Coil A second closing coil type is available replacing the standard type. This device offers an extended functionality with all the features of the standard device. Additional connections allow this type to be wired out through the trip unit and to be accessed electrically through the communications bus. It is supplied with an extra ON push button that ts onto the breaker front facia. Fitting between the two existing ON and OFF buttons gives the user an extra electrical ON option locally. The coils can be used in an operating frequency of up to two operations per minute and have a life span equivalent to that of the full breaker life span. Connnections The Closing coils & Command closing coils connection points can be found on terminal A of both the Fixed Pattern & Draw out Breaker types.
A10 A11 A10 A11
PH PH
Command CC

Intro A B C D E F

Connnections The Charging mechanism connection points can be found on terminal A of both the Fixed Pattern & Draw out Breaker types.
A1
SPRING CHARGE MOTOR

A3
SPRING CHARGED

A3
READY TO CLOSE

CC

OR
N

OR
A4

A9

A9

A2

A4

Electrical characteristics Electrical characteristics


Control Voltage Motor Operator Envelope 1 Motor Operator Envelope 2 & 3 AC -48V -110-130V 220-240V 277V 380-415V 440V DC 24V 48V 60V 110-130V 220-240V 250V --Power Consumption

X
350 VA Inrush

Power Consumption 24-30V DC, 48V DC, 60V DC, 110-130V DC, 220 - 250V DC 48V AC, 110-130V AC, 220-240V AC, 380-400V AC, 440V AC 300W 350VA 480W 560VA

C.3

EntelliGuard G
Shunt & Undervoltage Releases
Shunt Release A device designed to switch the Power Circuit Breaker OFF remotely. When energized a Shunt Release instantaneously activates the circuit breaker mechanism thus ensuring a rapid disconnection of the main contacts (50msec). All EntelliGuard G Shunt Release are suitable for a continuous power supply and are designed to be used as a closure prevention device when energized. Two Shunt Releases can be mounted in each Power Circuit Breaker. The device is available as a factory mounted component or as a eld mountable device. It is an extremely easy-to-t, clip-on unit, with simple plug-in connectors. The individual devices have a wide voltage range, thus limiting the number of devices needed and have a life span equivalent to that of the full breaker life span. Connnections The connection points of both releases can be found on terminal A of both the Fixed Pattern & Draw out Breaker types. As it is possible to mount a total of three of these releases, the connection scheme also includes a 2nd optional UVR or Shunt release.
A7 A12 A5 A5

Breaker Accessories

UV1

OR
A6

A8

A13

A6

Electrical characteristics releases


AC -48V -110-130V 220-240V 277V 380-415V 440V DC 24V 48V 60V 110-130V 220-240V 250V --Power Consumption

Intro A B C D E F X
Undervoltage Release A device designed to open the breaker contacts and to prevent the breaker from closing when in a No volt condition. On a de-energization the Undervoltage release activates the circuit breaker mechanism and ensures a rapid disconnection of the main contacts (50 Milliseconds). When not re-energized in accordance to the conditions stated in the IEC 60947 the device prevents the Power Circuit Breaker from closing. The EntelliGuard G Undervoltage releases are designed to react within a pre-dened Voltage band, only reacting when the voltage supplying drops below the limits of this band. To prevent nuisance tripping due to short power interruptions or Brown Outs the device has a built in delay of 50 Milliseconds. Two Undervoltage Releases can be mounted in each Power Circuit Breaker. The device is available as a factory mounted component or as a eld mountable device. It is an extremely easy-to-t, clip-on unit, with simple plug-in connectors. The individual devices have a wide voltage range, thus limiting the number of devices needed and can be used in a operating frequency of up to two operations per minute. The releases can have a life span equivalent to that of the full breakers life span.

350 VA / 350 W Inrush 60 VA / 50W Holding

Time Delay Module The de-energizing operation of the Undervoltage release can be delayed. This optional, externally mounted module has an adjustable time delay of zero to three seconds. The device can be implemented to prevent undesired Breaker tripping due to momentary voltage interruptions and is connected in series with the Undervoltage release. Optionally, the EntelliGuard G Trip Unit can be supplied with a three phase plus neutral Undervoltage protection device that can provide a power interruption alarm and/or initiate a breaker trip.

Electrical characteristics releases


AC 48V --110-130V -220-240V -250-277V 380-415V 440V DC -48V 60V -110-130V -250V ---Power Consumption

C.4

UV2 350 VA Inrush 60 VA Hold

ST1

ST2

EntelliGuard G
Interlock Devices, Indication Contacts and Number of devices

Releases, Interlocks and Contacts

Network Interlock Device When devices as the EntelliGuard G Power Circuit Breaker are used in Automatic or Manaul Power Transfer systems, local access and operation of the device can be undesirable. The Network Interlock Device is an optional mechanical lockout device that can be added to electrically operated circuit breakers. It is a logic driven interlock with two positions, LOCKOUT and RESET. The Network Interlock is locked out and reset by means of voltage pulse applied across respective terminals. Setting the Network Interlock to LOCKOUT when the breaker is closed causes the breaker to trip. In the LOCKOUT position, the Network Interlock holds the breaker mechanically trip free and also inhibits electrical closing. A command to reset the Network Interlock must be provided before the breaker can be closed manually or by control logic. Loss of control power does not cause the Network Interlock to reset. The Network Interlock can also RESET by pushing the reset button provided on the front face of accessory. The device is available as a factory mounted component and has the volume of two releases (Shunt/Undervoltage).

Release Indication Contacts To indicate, if a Shunt or an Undervoltage release initiation has resulted in a breaker, OFF or TRIP, a contact can be tted to the releases. The contacts are available in two versions; one power rated for use in standard Circuits and a second signal rated type for use with the Electronic Trip Unit communication option. The contacts are available as a factory mounted component or as a eld mountable device. They are extremely easy-tot, clip-on units, with simple plug-in connectors.

Connnections The connection points of the power rated contacts can be found on terminal B of both the Fixed Pattern & Draw out Breaker types (1). The Signal rated types are connected to the Electronic Trip Unit and are only accessible through the optional Communication option.
B4 B17
ST1 STATUS CONTACT CC STATUS CONTACT

Intro A B C D

B6
UV1 STATUS CONTACT

B19
ST2/UV2 STATUS CONTACT

Connnections The device replaces 1 Shunt and 1 Undervoltage release and is wired out to the same connection points located on terminal A of both the Fixed Pattern & Draw out Breaker types. Number of devices The EntelliGuard G Power Circuit Breaker can be equipped with up to 4 of the releases mentioned on pages C2 and C3. Shunt Release (Shunt), Closing & Command closing coils (CC/CCC) and Undervoltage Releases (UVR) can be mounted in the following combinations. The Network Interlock device as described above takes 2 of the indicated 4 spaces.
Coil position on front facia, from left Combination A B C D 1 Network Shunt Shunt Network 2 Interlock Shunt UVR Interlock 3 CC/CCC CC/CCC CC/CCC CC/CCC 4 UVR UVR UVR Shunt

OR

B5

B18

B7

B20

Electrical characteristics Power Rated types


AC Ratings Voltage 250V Amps AC21-6A DC Ratings Voltage 125V 250V Amps DC21-0.4A DC21-0.2A

E F X

Minimum Operating Current 0.16 A at 5V DC

Signal Rated, gold plated contact types


AC Ratings Voltage 125V Amps AC21-0.1A DC Ratings Voltage 8-30V Amps DC21-0.1A

Minimum Operating Current 1mA at 5V DC

(1) The use of these devices limits the wiring out of some auxiliary contacts (see section E for full schematics)

C.5

EntelliGuard G
Auxiliary Contacts
Auxiliary Contacts Auxiliary contacts are designed to indicate the position of the Power Circuit Breaker main contacts. Each EntelliGuard G device is supplied with a standard package of 3 Normaly open (NO) and 3 normally closed (NC) contacts that operate simultaneously with the breakers main contacts. Optionally other packages are available that can be used to increase the number of available contacts by replacing the standard auxiliary contact block. Auxiliary Contact packages - Power rated contacts 8 NO & 8 NC(1) - Power rated contacts 3 NO & 3 NC plus Signal rated contacts 2 NO & 2 NC - Power rated contacts 4 NO & 4 NC plus Signal rated contacts 4 NO & 4 NC(1) The devices are available as factory mounted components or as a eld mountable device. Auxiliary contact packages are easy-to-t, and have simple plug-in connectors.
B22

Connnections (1) The connection points of the Auxiliary contacts can be found on terminal A and of both the Fixed Pattern & Draw out Breaker types. When the standard 3 NO & 3 NC is required only the standard terminal A is used.

Breaker Accessories

B8

B10

B12

A14

A16

A18

NC6

NC5

NC4

NC3

NC2

B9

B11

B13

A15

A17

A19

B21

B23

B25

A20

A22

A24

NO6

NO5

NO4

NO3

NO2

Intro A B C D E F X
Connnections The connection points of the auxiliary contacts can be found on the two terminals (A & B) of both the Fixed Pattern & Draw out Breaker types. Electrical characteristics Auxiliary Contacts Power Rated types
AC Ratings Voltage 110-130V 220-240V 380-440V Amps AC21 - 15A AC23 - 10A AC21 - 10A AC23 - 5A AC21 - 5A AC23 - 2,5A DC Ratings Voltage 24V 110-130V 250V (3)
(2)

B24

B26

A21

A23

A25

B17

B19

B6

B4

NO8

NO7

NC7

B18

B20

B7

B5

Amps DC21 -15A DC21 -10A DC21 -5A

Minimum Operating Current 0.1 A at 8V DC

Signal Rated, gold plated contact types


AC Ratings Voltage 250V Amps AC21-0.1A DC Ratings Voltage 8-30V Amps DC21-0.1A

Minimum Operating Current 10 mA at 5V DC

(1) The use of these devices limits the wiring out of some auxiliary contacts (see section E for full schematics) (2) Three contacts in series (3) Six contacts in series

C.6

NC8

NO1

NC1

EntelliGuard G
Bell Alarm, Cassette position indication, Spring Charged & Ready to close contacts
Bell Alarm Contact When an EntelliGuard G Power Circuit Breaker has tripped due to a fault detected by the tripunit, a Bell Alarm Changeover contact is available to indicate this. The Electronic Trip Units trip reason indicators and the optional release indication contacts providing the reason of the trip. The device is available as a factory mounted component or as a eld mountable device. The Bell Alarm contact is easy-to-t, and has simple plug-in connectors. The contact can only be used when the breaker is adjusted to manual reset. Connnections The connection points of the Bell Alarm contact can be found on terminal A of both the Fixed Pattern & Draw out Breaker types.
A34 A33
BA CONTACTS

Connnections The device is located in the left side of the cassette substructure and can be accessed and connected directly.

Auxiliary, Bell Alarm & indication contacts

Electrical characteristics Position Indication Contacts


AC Ratings Voltage 250V Amps AC21-10A DC Ratings Voltage 125V 250V Amps DC21-0.5A DC21-0.25A

Spring Charged and Ready to Close Contacts A breaker with electrical charging mechanism can be optionally equipped with one or two indication contacts. The rst the Spring Charged Contact simply does as indicated and is supplied with the standard Motor Operating Mechanism. The second, the ready to close indication, optionally replaces the Spring Charged Contact. It only moves position when the following conditions are met: -> The circuit breaker is open -> The closing springs are charged -> The circuit breaker is not locked/interlocked in open position -> There is no standing closing order -> There is no standing opening order Both contacts are availble in a 1NO conguration. Connnections The connection points of these contacts can be found on terminal A of both the Fixed Pattern & Draw out Breaker types
A3
SPRINGS CHARGED

Intro A B C D E F

A35

Electrical characteristics Bell Alarm Contact


AC Ratings Voltage 250V Amps AC21-6A DC Ratings Voltage 125V 250V Amps DC21-0.4A DC21-0.2A

A3
READY TO CLOSE

Minimum Operating Current 0.1 A at 8V DC

Cassette Position Indication Contacts A breaker in draw out mode has a cassette that is used for mounting and connecting. The breaker, in its moving portion mode, can be inserted into the cassette and by use of the racking handle and it can be moved to one of three positions: Connected, Test, Disconnected or Withdrawn To indicate in which position the EntelliGuard G Breaker is located within the Cassette position is Indication contacts are available. The disconnected position is only being indicated when minimum isolating distances between contacts on both the main and auxiliary circuits have been achieved. The devices are available in two packages with 1 or 2 changeover contacts per position. Commonly referred to as Carriage switches they are available as a factory mounted component or as a eld mountable device.

OR

A4

A4

Electrical characteristics Power Rated types


AC Ratings Voltage 250V Amps AC21-6A DC Ratings Voltage 125V 250V Amps DC21-0.4A DC21-0.2A

Minimum Operating Current 0.16A at 5V DC

Signal Rated, gold plated contact types (4)


AC Ratings Voltage 125V Amps AC21-0.1A DC Ratings Voltage 8-30V Amps DC21-0.1A

Minimum Operating Current 1mA at 5V DC (4) Spring Charged contact NOT available in signal rated version

C.7

EntelliGuard G
Mechanical Interlocking of Multiple Breakers
Mechanically Interlocked Breakers Many Low Voltage Installations have multiple power sources that are used in many different congurations. The power sources are required to supply the installation simultaneously, alternatively or in a certain logical combinations of both. Three Breaker Interlock type B Interlock type B in which one of the three breakers (B1, B2 or B3) can be switched ON. Each breaker must be equipped with a factory mounted interlock type B. Six cables are needed.

Breaker Accessories

The EntelliGuard G Power Circuit Breaker can be used to protect these Power supplies and be electrically and mechanically interlocked to provide the necessary logic. The mechanical interlocks are available for xed and draw out circuit breakers, enabling the direct interlocking of the breakers, mounted side by side or stacked. The device has two parts; the rst a factory mounted component tted to the breaker when in Fixed Pattern or the cassette when used in draw out mode. Two or more specially designed eld mountable cables available in lengths of 1.0, 1.6, 2.0, 2.5, 3.0, 3.5 and 4.0 metres being the second. Any combination mode (xed or draw out), current rating, number of poles or envelope size can be interlocked. The interlocking systems are available in one conguration for 2 breakers and in three others for 3 breakers.

B1

B2

B3

Intro A B C D E F X
B1

Three Breaker Interlock type C Interlock type C in which one or two of the three breakers can be switched ON in accordance with the inserted diagram. Each breaker must be equipped with a factory mounted interlock type C. Six cables are needed.

B1 0 I 0 0 I 0 I

B2 0 0 0 I I I 0

B3 0 0 I 0 0 I I

Two Breaker Interlock Interlock type A in which one of the two breakers (B1 or B2) can be switched ON. Each breaker must be equipped with a factory mounted interlock type A. Two cables are needed.

Three Breaker Interlock type D Interlock type D in which one or two of the three breakers can be switched ON in accordance with the inserted diagram. Breakers B1 & B3 must be equipped with a factory mounted interlock type A and B2 with a interlock type D. Four cables are needed.

B2

B1 0 I 0 I 0

B2 0 0 0 0 I

B3 0 0 I I 0

C.8

EntelliGuard G
Locking previsions for Breaker and Cassette Door-Interlock systems; Mis insertion device
Standard Padlocking Facilities Breaker & Cassette EntelliGuard G Power Circuit Breakers are supplied with two standard padlocking devices. The breaker in Fixed and Draw out pattern have a padlocking facility for one padlock of 3-8mm allowing the breaker to be locked in its OFF position. Cassette Key lock facilities The Cassette of a Power Circuit breaker can be equipped with up to two Ronis or Profalux key locks. The key lock system encompasses a device tted to the cassette allowing the locks and the separate locks to be tted. The device ensures that a draw out circuit breaker cannot be moved from the TEST or DISCONNECT position unless the key has been inserted and secured within the lock. The locks also prevent the breaker from (all positions) being switched on. The device allows up to 2 Ronis 1104 or Profalux locks. The locks must be purchased as separate items. Door Interlock A device designed to prevent the door of the equipment in which the breaker is installed to be opened when the Power Circuit breaker is in connected position. It is available in two executions; one for a door opening to the left and one to the right.

Mechanical Interlocking and Locking

The cassette supplied with the breakers in draw out mode has three facilities for up to 3 padlocks(1) of 3-8mm. Two of these can be found on the cassette euchenon and can be used for locking the shutters in closed position or closing and locking the racking handle aperture. The third option is located on the breaker draw out support slides and can be used to lock breaker & chassis combination in disconnected position. Facia Pushbutton Padlocking Facilities To prevent un-authorized access to both the ON and OFF push buttons on the breakers front facia, a padlockable push button cover can be xed to the breaker front facia. 1 padlock of 3-8mm can be used.

Intro A B C

Mis Insertion Device By incorporating this optional security interlock device into the draw out cassette, an inadvertent insertion of an incorrect rated moving portion is prevented. Before using the interlocking system, the misinsertion logic needs to be set on both the breaker and the device.

D E F X

Breaker Key lock facilities A Power Circuit breaker can be equipped with up to four key locks. The key lock system encompasses a device tted in the front facia allowing the locks to be tted and the separate locks. These devices ensure that a circuit breaker cannot be closed unless the key has been inserted and secured within the lock. Devices are available for 1 Castell or Kirk lock and 4 Ronis 1104 or Profalux locks. The separate Ronis and ProAux.locks are part of the EntelliGuard G product offering the Castell and Kirk locks must be acquired elsewhere.

(1) Shutter lock, maximum 1 padlock of 3-8 mm.

C.9

EntelliGuard G
Installation Accessories
Operations Counter A simple and easy to install mechanical device that displays an accurate and cumulative record of the number of closing operation of the EntelliGuard G Power Circuit Breaker in which it is installed. The mechnical and electrical life span of the breaker can be extended by limited periodic maintenance. The counter contains information that can assist in determening when. Wall Mounting Brackets EntelliGuard G Power Circuit Breakers are designed to be mounted within a frame inside a low voltage Distribution or Control panel. In some cases, specically when the front connection option is used, wall mounting can be more expedient. For this purpose wall mounting brackets are available for the breakers in Fixed Pattern, envelope 1 and 2.

Breaker Accessories

Intro A B C D E F X

Contact Wear Indicator A second simple and easy to install mechanical device that can be used to ascertain when breaker maintenance is needed. Mounted above the contacts of a breaker in draw out mode it allows the user to physically see the contacts and contains markers to determine their wear.

Sensors, Rogowski coils If the EntelliGuard G Electronic Trip Unit is congured to allow Earth/Ground fault protection an external Neutral sensor can be required. Rogowski coils for this application are available as separate items and are supplied with a mounting kit. For the correct sensor choice and application details see page B.14 of this catalogue.

Terminal Block Breakers in Fixed Patter, cassettes and breakers in Draw out mode are always supplied with an auxiliary connection block suitable for 39 connection points (terminal A). When the number of factory installed accessories exceeds the available number of connection points needed, a 2nd connection block is automatically added (terminal B). For cases where the accessories are mounted in the eld, separate auxiliary connection block are available; two types suited for the breakers in xed pattern (39 or 78 pole) and one for breakers in draw out mode (adding 39 poles). IP54 Cover All Power Circuit Breakers are supplied with a door ange/door frame that allows the user to nish the door cut out professionally, simultaneously providing a protection degree of IP31. If a higher protection degree is required, an additional cover is available allowing IP54.

Sensors, Current transformers If the EntelliGuard G Electronic Trip Unit is congured to allow Earth/Ground fault protection an external Neutral sensor can be required. In most standard applications a Rogowski coil sufces, however in some cases other Sensors are needed. Current Transformer are used for Source Ground return Earthfault applications. If combinations of earthfault options as UEF, REF & SEF are required multiple sensors could be required. Current Transformers for these application are available as separate item and are supplied with a mounting kit and an extra interposing Current Transformer needed in some specic cases. For the correct sensor(s) choice and application details see page B.14 of this catalogue.

Lifting Truck Specically designed for use with the EntelliGuard G range, this dedicated handling truck is a useful accessory when faced with the task of inserting, removing or transporting the circuit breaker. The device is designed for use with envelope 1 and envelope 2 moving portions. For envelope 3 an adapter kit is available. The high location of some breakers installed in low voltage distribution panels and the weight and volume of these devices make this accessory particularly valuable.

C.10

EntelliGuard G
Installation Accessories and Spare Parts
Earthing device (maintenance accessory) Spare Parts
Earthing Device To allow either the incoming cables or the busbar to be safely held at earthed potential and locked during system maintenance, all EntelliGuard G Power Circuit Breakers can be tted with an earthing device. The device is available as a separate eld mountable accessory and has a Short-circuit rating equal to the short time withstand (Icw) of the breaker.

Spare parts for general use The EntelliGuard G Power Circuit breaker uses components that are designed to last the full life span of the device. However, certain components can be damaged or break during operational use. For these specic cases, the following spare parts are available: Cassette: moving portion Racking Handle (A) Shutters (B) Breaker (C): Front cover Locking devices: Set of 4 Ronis key interlock cams (A) (B) (C)

Intro A B

Spare part for maintenace purposes Air Circuit Breakers as the Entellliguard Power Circuit Breakers require periodic maintenance. Here, in some cases certain components critical to the devices functionality could need replacement. Please contact our service department for specialist assistance in establishing which components need replacement and the physical replacement activities. The following items are available: Arc Chutes (A) Fixed arcing Contacts (B) Cassette cluster contacts (C) Pliers to remove Cassette cluster contacts (D) (A) (B)

C D E F X

(C)

(D)

C.11

EntelliGuard G
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Intro A B C D E F X

EntelliGuard G

Application Guide D.2 D.3 D.5 D.6 D.7 D.8 D.9 Handling, Mounting and Connecting Heat Dissipation, Watt loss & Current Ratings at temperatures > 50C Selectivity/Discrimination Selectivity with downstream devices, tables Protection of standard Circuits Applications Environmental Considerations

The breaker Order Codes Electronic Trip Units Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

Intro A B C D E F X

D.1

EntelliGuard G
Handling, Mounting and Connecting
Clearance distances A modern circuiit breaker is designed to interrupt high Short-circuit currents in a very limted time frame. In doing so the breaker vents gas and a limited amount of conductive fragments. EntelliGuard G Power Circuit Breakers have been designed to limit the venting phenomenon to a minimum, but certain clearances do need to be taken into account as indicated in the front and side views. The maintenance of the xed pattern devices requires access to the contacts and the removal of the Arc Chutes. A certain distance needs to be left above the breaker to allow for this as indicated in the front and side views. Front View Fixed or Draw out Pattern

A B1 B2

Application Guide

Minimum Clearance distances on Fixed Pattern breaker from housing to: Metal Parts A(1) B1 B2 160 30 30 Insulated parts 160 30 30

Side View Fixed Pattern

Minimum Clearance distances from Draw out cassette housing to: Metal Parts Insulated parts 0 30 30
B1

182mm min to remove Arc Chute

Intro A B C D E F X

A B1 B2

0 30 30

(1) Dimension allows for eld Arc Chute replacements

Handling EntelliGuard G Breakers in the xed pattern & as draw out portion have two retractable lifting eyes. One of these is located on the breaker right hand side and a 2nd on the left (see sketch). The cassettes have four re-enforced tilting points with M10 screw thread. Recommended Connection Cross sections The adjacent table indicates the recommended bus bar dimensions to be used in connecting the EntelliGuard G Power Circuit Breaker. The current ratings of the devices with these recommended bus bar connection sizes are indicated on page D3 & D4.

Side View Fixed or Draw out Type


Dia 26 Hole

Breaker type Automatic GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GH32N, H & M GG32G & L GG40N, H & M GH40N, H & M GG40G & L GG50M & L GG64M & L

Switch Type Envelope In in A Non Automatic GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GK32N & GZ32H GJ32G GJ40N & GW40H GK40N & GZ40H GJ40G CJ50L CJ64L

1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 2 1 2 2 2 or 3 2 3 3 3

400 630 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6400

Recommended Copper Bus Bar sizes 1 x 40 x 10 or 1 x 80 x 5 or 2 x 40 x 5 1 x 50 x 10 or 1 x 100 x 5 or 2 x 50 x 5 1 x 50 x 10 or 1 x 100 x 5 or 2 x 50 x 5 1 x 60 x 10 or 2 x 60 x 5 2 x 40 x 10 or 2 x 80 x 5 2 x 50 x 10 or 2 x 100 x 5 3 x 50 x 10 or 3 x 100 x 5 4 x 50 x 10 or 4 x 100 x 5 4 x 100 x 10 4 x 100 x 10 Plus 1 x 100 x 5 4 x 100 x 10 5 x 120 x 10 or 6 x 100 x 10 7 x 120 x 10 or 8 x 100 x 10

D.2

EntelliGuard G
Heat Dissipation, Watt loss & Current Ratings at temperatures >50C
Standards The standard for low voltage equipment is dened in the EN 60439-1, the EN 50298 and the IEC 60890. These provide a theoretical method to calculate the temperature rise within an enclosure. The main element in these calculations is the power dissipation of the equipment installed. By totalizing this value for all the installed devices, connections, cables and busbars it is possible to calculate the temperature rise within the enclosure. For normal applications a temperature rise within the enclosure of 50 Kelvin is assumed. Use An enclosure manufacturer can provide the exact data on the allowable power dissipation within a certain enclosure. The values depend on the enclosure type, the ventilation it offers and where the components are located within this enclosure. EntelliGuard G Power Circuit breakers The devices have been designed to offer the lowest, feasible heat dissipation value and the highest possible current ratings when enclosed. The tables here indicate the heat dissipation values and current ratings at temperatures within the direct vicinty of the breaker in free air. The values apply for breakers used with rear connections and the preferred vertical busbars. The recommended connection cross sections and busbar sizes can be found on page D.2.

Breaker type Automatic

Switch Type Non Automatic

Envelope

In in A

Power loss at In per pole (W) 2.29 1.66 5.68 4.13 9.15 6.66 14.3 10.4 22.3 16.3 36.6 26.6 57.2 41.6 65.0 106 66.6 166 104 163 266

Temperature in the direct environment of the EntelliGuard 50C 55C 60C 65C 70C Maximum user Current Ie in A Vertical connection mode: Fixed pattern 400 400 400 400 400 400 400 400 400 400 630 630 630 630 630 630 630 630 630 630 800 800 800 800 800 800 800 800 800 800 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2500 2500 2500 2500 2500 3200 3200 3200 3150 3100 3200 3200 3200 3200 3200 4000 3750 3500 3350 3200 4000 4000 4000 4000 4000 5000 5000 5000 4900 4800 6400 6300 6200 6100 6000 Maximum user Current Ie in A Vertical connection mode: Draw out types

Intro A B C D E F X

Watt Loss & De-rating

GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GG32G & L GG40N, H & M GG40G & L GG50M & L GG64M & L

GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GJ32G GJ40N & GW40H GJ40G GJ50L GJ64L

1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 3 2 3 3 3

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 4000 4000 5000 6400

GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GH32N, H & M GG32G & L GG40N, H & M GH40N, H & M GG40G & L GG50M & L GG64M & L

GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GK32N & GZ32H GJ32G GJ40N & GW40H GK40N & GZ40H GJ40G GJ50L GJ64L

1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 2 3 2 2 3 3 3

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 4000 4000 4000 5000 6400

4.78 3.74 11.9 9.29 19.1 15.0 29.9 23.4 46.7 36.6 76.5 59.9 120 93.6 146 240 186 106 374 291 166 260 426

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3800 4000 4000 5000 6400

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3650 3950 4000 5000 6300

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3500 3900 4000 5000 6200

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200 3350 3835 4000 4900 6100

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3000 3200 3200 3100 3750 4000 4800 6000

D.3

EntelliGuard G
Heat Dissipation, Watt loss & Current Ratings at temperatures >50C
EntelliGuard G Power Circuit breakers Other connection modes as rear connection with horizontal busbars and connection from the breaker front are possible. The tables here indicate the heat dissipation values and current ratings at temperatures within the direct vicinty of the breaker in free air. The values apply for breakers used in rear connection mode with horizontal busbar connection and for devices with front connection. The recommended connection cross sections and busbar sizes can be found on page D.2.

Application Guide

Breaker type Automatic

Switch Type Non Automatic

Envelope

In in A Power loss at In per pole (W)

Temperature in the direct environment of the EntelliGuard 50C 55C 60C 65C 70C Maximum user Current Ie in A (2) Horizontal or Front connection mode: Fixed pattern 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200
(1)

Intro A B C D E F X

GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GG32G & L GG40N, H & M -RH GG40N, H & M-FC GG40G & L GG50M & L GG64M & L

GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GJ32G GJ40N & GW40H-RH GJ40N & GW40H-FC GJ40G GJ50L GJ64L

1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 3 2 2 3 3 3

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200
(1)

2.29 1.66 5.68 4.13 9.15 6.66 14.3 10.4 22.3 16.3 36.6 26.6 57.2 41.6 65.0 106 66.6
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3100 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3050 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3000 3200
(1)

4000 4000 5000


(1)

166 104 163


(1)

4000 4000 5000


(1)

3700 4000 5000


(1)

3400 4000 5000


(1)

3200 4000 4875


(1)

3000 4000 4750


(1)

Maximum user Current Ie in A Horizontal or Front(2) connection mode: Draw out types GG04, S N & H GG04 E and M GG07, S N & H GG07 E and M GG08, S N & H GG08 E and M GG10, S N & H GG10 E and M GG13, S N & H GG13 E and M GG16, S N & H GG16 E and M GG20, S N & H GG20 E and M GG25N, H & M GG32N, H & M GH32N, H & M GG32G & L GG40N, H & M -RH GG40N, H & M-FC GH40N, H & M GG40G & L GG50M & L GG64M & L GJ04S & GW04N GJ04H GJ07S & GW07N GJ07H GJ08S & GW08N GJ08H GJ10S & GW10N GJ10H GJ13S & GW13N GJ13H GJ16S & GW16N GJ16H GJ20S & GW20N GJ20H GJ25N & GW25H GJ32N & GW32H GK32N & GZ32H GJ32G GJ40N & GW40H-RH GJ40N & GW40H-FC GK40N & GZ40H GJ40G GJ50L GJ64L 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 2 2 3 2 2 2 3 3 3 400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200
(1)

4.8 3.74 11.9 9.3 19.1 15.0 29.9 23.4 47 36.6 77 60 120 94 146 240 186 106
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3200 3200
(1)

400 400 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 2900 3000 3200
(1)

4000
(1)

374
(1)

4000
(1)

3700
(1)

3400
(1)

3200
(1)

3000
(1)

4000 5000
(1)

166 260
(1)

4000 5000
(1)

4000 5000
(1)

4000 5000
(1)

4000 4850
(1)

4000 4700
(1)

(1) Rear horizontal connections cannot be used at this current rating (2) Front connections are available for the standard envelope 1 and envelope 2 types (not available for GH,GK and GZ types)

D.4

EntelliGuard G
Watt-Loss, Current Ratings, Selectivity
Selectivity/Discrimination
Selectivity - Discrimination In a low voltage distribution network it is necessary that on a fault the protection device nearest to the fault reacts whilst all others remain closed. This capability is called discrimination (UK) or Selectivity (USA and Europe). If this requirement is not met a fault in one arm of the distribution system could cause a number of upstream protection devices to react and open. A relatively minor fault in one arm of a complete distribution will then cause a power interruption across a major part of the installation. EntelliGuard G Power Circuit breakers A combination of the high precision and multiple bands of the EntelliGuard G Electronic Trip Unit allow full selectivity to be achieved between closely rated devices over multiple levels. The table included here indicates the recommended settings of the downstream protection devices and the upstream EntelliGuard G breaker. A second table on page D.6 indicates the discrimination / selectivity that can be achieved with these settings. The tables can replace the Complex and Time consuming method of comparing multiple Time Current curves across many levels.

Downstream Device Record Plus

Trip Unit

Setting Denomination

Settings determining selectivity

Recommended EntelliGuard G settings Ir or Ie setting Ratio 1.6 x 1.6 x 1.3 x C8 C14 1.35 x 1.3 x C8 C14 1.35 x 1.3 x C3 C5 C8 C12 C16 C18 1.35 x Band 13 Band 11 Band 9 Band 6 Band 3 1.4 x C8 1.35 x Band 7 1.4 x C8 C12 C19 C22 Band 12 Band 10 Band 7 1.25 x 2 higher 1.25 x 2 higher 1 higher 1.25 x 2 higher 1.25 x 2 higher 1 higher 2x F20 ST = 8 x Ir, STDB band 5 and I = 12 x Ie Use ZSI or I = OFF Minimum setting 16kA -FK800, 20kA - FK1000 20kA - FK1250 28kA - FK1600 or use ZSI or I = OFF Minimum setting 12.5kA -FG400, 14kA - FG630 or use ZSI or I = OFF Band 3 Band 2 LTDB setting band C22 1.6 x C22 1.6 x Band 2 Band 2 Minimum setting 5kA -FD160, 7kA - FE160, 9kA - FE250 or I = OFF Ist setting Ratio STDB setting band I setting

Ir Im Ir FD& FE frame GTM Im Ir LTD line FE frame SMR1 LTD Motor Ist Ir LTD line FG frame SMR1 LTD Motor Ist Ir LTD cl.1.25 LTD cl. 2.5 LTD cl. 5 LTD cl.10 LTD cl.20 FG frame SMR2 LTD cl.30 Ist STD=420ms STD=310ms STD=210ms STD=120ms STD=40ms Ir FK frame SMR1e Ist STD Ir LTD cl. 5 LTD cl.10 LTD cl.20 FK frame SMR1s LTD cl.30 Ist STD=300ms STD=200ms STD=100ms Ir LTD class EnteliGuard GT-E Ist STD band min. until 11 STD band 12 Ir LTD class EnteliGuard GT-S, N & H Ist STD band min. until 11 STD band 12 Industrial fuses ---Current rating GL/Gg type FD& FE frame LTMD

Ratio & Band Ratio & Band Ratio & Band Ratio & Band Ratio & Band Band Band Ratio & Band Ratio & Band Band Band Ratio & Band Ratio Band Band Band Band Band Band Ratio Band Band Band Band Band Ratio & Band Ratio Band Ratio Band Band Band Band Ratio Band Band Band Ratio Band Ratio Band Ratio Band Ratio Band Ratio & Band

Intro A B C D E F X

D.5

EntelliGuard G
Selectivity with downstream devices, tables
Upstream EntelliGuard G device and Selectivity limit Is (1) Downstream Device Trip Unit GG04S to GG20S T GG04N to GG20N T GG25N to GG40N T GG04E to GG20E T GG(H)25H to GG(H)40H T GG(H)25M to GG(H)40M T GG32G to GG40G T GG40M to GG64M T GG40L to GG64L T

Intro A B C D E F X

Elfa Plus MCBs EP30,45, 60,100&250, CP30,45&60, DME60, DPE100, DP(A)60, DP(A)100 & DPT100 Elfa Plus MCBs HTI & S90 C curve Surion Manual Motor starters GPS1BS 10A GPS1MH 12.5A GPS2BS 10A, GPS2MH 10A Surion Manual Motor starters GPS1BS, GPS1MS 12.5kA, GPS1MH > 12.5A GPS2MH >10A Surion Manual Motor starters GPS1BS, GPS1MS 16A, GPS2BS >10A Record Plus FD& FE frame C, E, V, S tiers FD& FE frame N tier FD& FE frame H tier FD& FE frame L tier FG frame N tier FG frame H tier FG frame L tier FK frame N tier FK frame H tier FK frame L tier EntelliGuard GG04S to GG20S GG04N to GG20N GG04E to GG20E GG(H)25H to GG(H)40H GG(H)25M to GG(H)40M GG(H)40M to GG(H)64M GG(H)40L to GG(H)64L Industrial fuses GL/Gg type

All

All

Application Guide

All

All

All

All All All All All All All All All All All All All All All All All ----

T T T T T T T T T T 50kA (2) 50kA (2) 50kA (2) ----T

T T T T T T T T T T T 65kA (2) 65kA (2) ----T

T T T T T T T T T T T 65kA (2) 65kA (2) 65kA (2) 65kA (2) --T

T T T T T T T T T T T T 85kA (2) ----T

T T T T T T T T T T T T 85kA (2) 85kA (2) 85kA (2) --T

T T T T T T T T T T T T 85kA (2) 85kA (2) 85kA (2) --T

T T T T T T T T T T T T T T T --T

T T T T T T T T T T T T T T T 100kA (2) 100kA (2) T

T T T T T T T T T T T T T T T 100kA (2) 100kA (2) T

(1) T = Full selectivity until the Icu of the downstream or upstream device (the lowest of the two) (2) Indicated values apply with I (Instantaneous) ON, If Off reduce by 10%

D.6

EntelliGuard G
Protection of standard Circuits
Protection of Standard Circuits Protection devices as the EntelliGuard G Power Circuit breaker are used in a wide variety of environments to protect conductors, equipment and devices in low voltage distribution circuits. To use this product to its full potential it is necessary to verify that it functions correctly in the environment in which it is used, and that it meets the Electrotechnical requirements of the circuit it protects. Environment EntelliGuard G will function well in almost any industrial environment and fully complies with the environmental requirements of the relevant EN 60 947-2 standard. For conditions other than the above mentioned, please refer to page D.9 of this section. Maximum Short-Circuit Current Each protective device must be capable of interrupting the maximum Short-circuit current at the point where it is installed (See HD 384 standard). The interruption ratings (Breaking Capacities) of the EntelliGuard G circuit breaker can be found on pages 2, 3 & 4 of this catalogue. Design Current of a circuit The equipment and devices in an electrical circuit determine its current load or design current Ib. A circuit breakers overload or Ir setting is normally adjusted to a value equal to the design current. Weakest Short-circuit current in a circuit On a Short-circuit event the total circuit impedance determines both the MAXIMUM and WEAKEST Short-circuit current that can ow in the circuit. It is therefor also necessary to verify that the device protecting the circuit reacts to the lowest possible Short-circuit current BEFORE the electrical conductors within the circuit exceed their maximum temperature. Fault Currents On a fault to Earth a current owing in the circuit must be interrupted before inadvertent contact to normally non-conductive parts can cause damage. In the commonly used TN system the following disconnection times apply (See HD 384 standard). EntelliGuard G Power Breakers are capable of interrupting the circuit within these times. EntelliGuard G Power Circuit breakers To protect standard circuits, the breakers are equipped with a number of protection devices. Overload Protection device The rst is a highly accurate menu driven overload protection device that has an adjustment range of 0.2 to 1 x the breaker rating. Six main current ratings (Ie) are available. Each have a sub setting (Ir) of 0.5 to 1 times the chosen Ie rating. This device is normally set to a value that is equal or closely matches the design current (Ib). Timed Short-circuit Protection Device Set as a multiple of the overload adjustment. this device offers a broad adjustment range of 2 to 12. The setting of this device depends on several parameters as the inrush characteristics of the protected devices. a protection against the weakest Short-circuit current and in some cases against fault currents to earth. 17 narrow and accurate time bands allow the EntelliGuard G Power Circuit Breaker to interrupt a fault within the timing required by the standards. to offer selectivity across multiple levels and allow the user to take inrush currents into account. Ground Fault Protection It is possible to combine two devices in one. both designed to detect Fault Currents to earth. They can be set as a multiple of the value of the Current Sensors mounted in the breaker and have a broad adjustment range of 0.2 to 1 (0.1 -1 with an auxiliary power supply). The rst is a residual device that takes the sum of the current in the three phases and neutral. If this is no longer equal to zero it sends an alarm or trips the breaker. The second allows the user to measure the return current running between the Earth leg and neutral. On detecting a fault to earth the device sends an alarm, or trips the breaker. 14 narrow and accurate time bands allow the EntelliGuard G Power Circuit Breaker to interrupt a fault within the timing required by the standards and offer selectivity across multiple levels. Instantaneous Short-circuit Protection Set as a multiple of the primary overload adjustment Ie this device offers a broad adjustment range of 2 to 15 (2-30 on request). This device is normally used to limit the time that higher Short-circuit currents can run in the protected circuit. Whilst the timed Short-circuit protection device waits for a set time, the instantaneous device immediately trips the breaker once the set value is reached. The device used in the EntelliGuard G Power Circuit Breaker maintains selectivity by only reacting to the 2nd half wave of a Short-circuit current and uniquely allows the use of the Zone Selective Interlock feature (see section B )

Intro A B C D E F X

Protection of Standard Circuits

Network voltage Phase-Neutral U0 127V 230V 400V > 400V

Maximum disconnecting time (AC system) 0.8 sec. 0.4 sec. 0.2 sec. 0.1 sec.

D.7

EntelliGuard G
Applications
Protection of Generator sets, Motors, Capacitor banks and Transformers Use of EntelliGuard G Breakers in Automatic Power Transfer Systems (ATS) Introduction The Electronic Trip Unit used in the EntelliGuard G Power circuit breaker offers many additional protection devices, a full description of which can be found in section B. Here a number of the possible applications of these devices is described briey. Protection of Generator sets The overload and Short-circuit devices used to protect a generator need to react quicker and at lower current levels than those used to protect other devices. After establishing the capabilities of the generator set under overload and Short-circuit conditions, the protection devices need to be adjusted accordingly. On a Power Circuit breaker use of the faster overload protection bands (LTDB set between Minimum and the C6 band) and a low setting of the timed Short-circuit protection (2.5 x Ir) is recommended. The optional 3 phase Undervoltage protection available in the GT-H trip unit can also be considered. Protection of Motors On starting electrical Motors draw more current than when running under normal conditions. These starting currents differ strongly per type and should not cause tripping of the device protecting the circuit. The IEC 60947-4 has dened four different operational or Trip classes:
Required tripping times at

Remark For an overview of the used abbreviations (as LTDB and STDB) see page B.22. Furthermore, the prevention of anomalies as the motor losing a phase or a motor with blocked rotor need to be prevented and require additional protection devices. Next to the standard protection devices the EntelliGuard G Electronic Trip Unit has a thermal memory function, an optional 3phase Undervoltage relay and current unbalance device thus providing comprehensive motor protection. Protection of Capacitor banks Power Circuit breakers are designed to offer high making and breaking capacities under adverse conditions: The switching of capacitor banks has little to no effect on the breaker, its characteristics as a protective device or on its lifespan. However the current owing in the circuit can trip a circuit breaker and a capacitor load does display certain anomalies. Here the current owing in the circuit cannot be assumed to be the calculated capacitor current only. The effective current value is higher due to harmonic content (normally assumed as 30%) and an allowance must be made for tolerances in the capacitance of the units (10%). The protection devices of the Power Circuit Breaker must be set accordingly. Protection of LV/LV Transformers. Transformers generally produce a very high inrush current. The crest values of the rst half cycle may reach values of 15 to 25 time the normal rated current. Manufactures data and tests have indicated that a protection device feeding a transformer must be capable of carrying the following current values without tripping.
imum crest inrush values 1st period 25 x In 15 x In 2nd period 12 x In 8 x In After 3 periods 5 x In 3.5 x In

Intro A B C D E F X

Application Guide

Transformer value 7.2 x In < 50 kvA 50 kvA

Trip class 10A 10 20 30

1.2 x In t < 2 hours t < 2 hours t < 2 hours t < 2 hours

1.5 x In t < 2 min. t < 4 min. t < 8 min. t < 12 min.

2 t < 10 sec. 4 t 10 sec. 6 t 20 sec. 9 t 30 sec.

This table is in some cases extended to include a trip class 40 (assumed to be a 15-40 second band at 7.2 x In). On a Power Circuit breaker, use of the slower protection bands that closely match the indicated classes is recommended (LTDB set between the C8 to the C22 band). Switching on a Motor also produces a high but very short inrush peak current which could activate the Short-circuit protection of a breaker and cause unexpected tripping. Here the timed Short-circuit device of a Power Circuit Breaker must be set to at least 12 x Ir with a time delay of 50 Milliseconds (STDB band 3). If an instantaneous protection device is present and switched on, a setting of at least 12 x Ie is recommended. After an overload event the Motor and wiring are still warm, immediate re-energization of the electrical circuit could result in damage of the electrical circuit and the motor. The overload protection device must incorporate a thermal memory device that prevents re-energization before a certain cooling time has elapsed.

It is recommended that the timed Short-circuit device of a Power Circuit Breaker is set to at least 8 x Ir with a time delay of 30 Milliseconds (STDB band 1). If an instantaneous protection device is present, the use of the extended adjustment range with setting of 20 x Ie is advisable (=15 x In plus tolerances). Automatic Transfer Systems EntelliGuard G Power Circuit breakers are available with mechanical interlocks for 2 to 3 breakers and have a unique electrical network interlocking system allowing the user to completely lock out one of more breakers. The logical transfer of power from one source to another is thus strongly simplied whilst the high speed electrical closing and opening of the device allows their use in synchronization applications. Here, numerous other EntelliGuard G protection features can be used, one of which being the Electronic Trip units 3 phase Undervoltage release. This to establish if voltage on a certain power source is present and if a generator set has reached its nominal voltage.

D.8

EntelliGuard G
Environmental Considerations
Ambient temperature EntelliGuard G Power Circuit Breakers are designed to operate normally at temperatures of -5 degrees to + 70 C. They can be used at temperatures down to -20C with a reduced electrical and mechanical life span. To prevent materials from reaching temperatures that have an adverse effect on their electrical and/or mechanical properties, de-rating factors must be applied when the device is used in ambient temperatures higher than 50 C. Storage temperature Power Circuit Breakers can be stored at non operational temperatures of -40 degrees up to + 70C. Electromagnetic compatibility The EntelliGuard G Power Circuit Breaker and its electronic trip unit meet the most stringent requirements off the EN60947-2 and IEC 1004 standard. The following tests have been successfully completed.

Application - Environment

Harmonics, current dips, interruptions and power frequency variations All EN 60947 Annex F, Sub-clause F4.1 through 3 requirements covering non sinusoidal currents resulting from harmonics are met. Testing covering the following elements: - Wave forms consisting of a fundamental + 3rd harmonic component at 50 and 60Hz - Wave forms consisting of a fundamental + 5th harmonic component at 50 and 60Hz - Composite wave forms with a fundamental component + a 3rd, 5th and 7th harmonic at 50 and 60Hz - Current dips and current interruptions - Frequency variations from 45 to 65Hz in 1 Hz steps Electrostatic discharge En 60947 Annex F, Sub-clause F and the IEC 1004-2 - Passed level 4, air discharge 15kV Radiated, radio frequency, electromagnetic eld immunity test EN 60947-2 Annex F, Sub-clause F7 and the IEC 1000-4-3 (basic standard) - Passed higher than level 4 . Field strength 30V/m Electrical fast transient/burst EN 60947-2 Annex F, Sub-clause F5 and the IEC 1000-4-4 (basic standard) - Passed level 4 burst peak voltage 4kV Surge immunity test EN 60947-2 Annex F, Sub-clause F5 and the IEC 1000-4-5 (basic standard) - Passed level 4 Voltage 1.2s/50s 6kV; current 8s/20s 3kA Dry heat test EN 60947-2 Annex F, Sub-clause F8 - Passed all test requirements Thermal shock test EN 60947-2 Annex F, Sub-clause F9 - No nuisance tripping within the 28-day temperature cycles

Inuence of Altitude Up to an altitude of 2000m above sea level no de-rating of breaker current or rated voltage is applicable. For altitudes above 2000m the following de-rating factors apply:
Altitude Correction factors Alttitude Voltage (Ue) Current (In) 2000M 1 1 2500M 0.95 0.99 4000M 0.8 0.96

Intro A B C D E F X

Other atmospheric conditions The EntelliGuard G breaker line has been designed to operate at the temperatures and relative humidities dened in the EN 60947 clause 6.1.3.1. They also meet the requirements of the following standards:

EC 68-2-1 EC 68-2-2 EC 68-2-3 EC 68-2-11 EC 68-2-14 EC 68-2-30 IEC 721

Cold Dry Heat Damp Heat Salt Change of Temperature Damp Heat cyclic Climatic

Shock and Vibration Power Circuit Breakers meet the shock and vibration requirements of the Lloyds Register of Shipping, the Germanische Lloyds and the American Board of shipping. They also meet the requirements of the following standards:

EC 68-2-6 EC 68-2-27 EC 68-2-29 EC 68-2-31

Vibration Shock test Bump Drop test

Other All EntelliGuard G devices meet the existing European ROHS directive and carry the CE mark.

D.9

EntelliGuard G
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Intro A B C E E F X

EntelliGuard G

The breaker Order Codes Electronic Trip Units


Wiring Diagrams E.2 E.4 E.6 E.7 Breaker Connection Schemes Terminal A Breaker Connection Schemes Terminal B Cassette & Trip Unit Connection Schemes Trip Unit Connection Schemes

Intro A B C D E F X

Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

E.1

EntelliGuard G
Breaker Connection Schemes
Standard use of Terminal block A
One Terminal block A is supplied with each breaker

LP1

LP4

Users designated circuits A34

Wiring Diagrams

A1

A3

A5

A7

A9

A12

A14

A16

A18

A20

A22

A24

A33

31 57 SPR M1

21

11

33

23

13 96 98 BAT

C1

D1

C3

D1 32 22 12 34 24 14 95 T A15 A17 A19 A21 A23 A25 A35 LP2 LP3

ML M2 58 C2 ST1 D2 UVR1 C4 CC D2 UVR2

A2

A4

A6

A8

A10

A13

Intro A B C D E
A10 A11 Users designated circuits A12

Users designated circuits

Optional use of Terminal block A


Optional use of Terminal block A Used with a Commmand Closing Coil (CCC) Used with a 2nd Shunt Release (Replacing 2nd UVR release) Used with a RTC contact (Replacing SPR contact)

Users designated circuits

LP5 A3

Users designated circuits

F
57

C3 C5 C4 CCC

RTC C1 C2 ST2

58

A9

A13

A4

Users designated circuits

Users designated circuits

Users designated circuits

E.2

EntelliGuard G

Optional use of Terminal block A

Breaker Connection Schemes

Used with a Network Interlock (NI) (Replacing 1 UVR and 1 ST)

Users designated circuits A5 A7

User designated circuits; indicators LP1: Spring charge status LP2: Breaker open LP3: Breaker closed LP4: Fault LP5: Breaker ready to close Terminology CC: Close coil ST: Shunt release UVR: Undervoltage release SPR: Spring change status RTC: Ready to close status M: Motor operator BAT: Bell alarm trip CCC: Comand close coil NI: Network interlock

E1 E3 E2 NI TRIP E4 NI RESET

A6

A8

Intro
Users designated circuits

A B C D E F X

E.3

EntelliGuard G
Breaker Connection Schemes
Standard use of Terminal block B
Terminal block B is supplied with factory mounted breakers, when needed.

Optional use of Terminal block


Used with a Network Interlock (NI) (Replacing 2 NO Aux. Contacts)

Wiring Diagrams

Users designated circuits B1 B6 B8 B10 B12 B17 B19 B21 B23 B25

LP10 B4 B5

Users designated circuits

81

71

61

51

41

83

73

63

53

43 66 68 NI

82

72

62

52

42

84

74

64

54

44

65

B5

B7

B9

B11

B13

B18

B20

B22

B24

B26

B6

Intro A B C D E F X
LP6 B4 LP7 B6 LP8 B17

Users designated circuits

Users designated circuits

Optional use of Terminal block B


Used with Coil indication contacts (Replacing 2 NC and 1 NO Aux. contact) Used with Coil Indication contact (Replacing 1NO Aux. contact)

Users designated circuits

LP9 B19

Users designated circuits

17

27

37

47

CC 18

UVR 28

ST1 38

ST2 48

B5

B7

B18

B20

Users designated circuits

Users designated circuits

E.4

EntelliGuard G

Optional use of Terminal block B

Breaker Connection Schemes

Used with Coil Indication contact (Replacing 1 NO Aux. Contact)

LP9 B19

Users designated circuits

User designated circuits; indicators LP6: CC powered LP7: UVR not powered LP8: ST powered LP9: ST2 powered/UVR2 not powered LP10: Network interlock lockout Terminology CC: Close coil ST: Shunt release UVR: Undervoltage release SPR: Spring change status NI: Network interlock

47

UVR2 48

B20

Intro
Users designated circuits

A B C D E F X

E.5

EntelliGuard G
Cassette & Trip Unit Connection Schemes
Optional Cassette Position Indication Switches

Users designated circuits

Wiring Diagrams

D11

D21

D31

D41

D51 51

D61 61

User designated circuits; indicators LP11: Breaker in disconnected position LP12: Breaker in test position LP13: Breaker in connected position

52 54 31 32 34 11 12 14 22 24 21 42 44 41

62 64 CONNECTED

TEST

DISCONNECTED

D14

D24

D34

D44

D54

D64

Intro A B C D E F X

D12

D22 LP11

D32

D42 LP12

D52

D62 LP13 Users designated circuits

Trip Unit - Type GT-E

A31

A32

A36

A37

24V+

24V-

N - RC -

N - RC +

+24VVDC N

Terminology 24V+/24V-: N-RC: RXD: TXD: TX_EN_I: 5V ISO: ISO GND: ELCT: RELAY O/P: RELAY I/P: V-A/V - B/V-C: GND: ZSI OUT: ZSI IN:

Auxiliary power supply to trip unit Neutral Rogowski coil Modbus/Probus communication Modbus/Probus communication Probus communication Probus communication Probus communication Earth leg ct Relay OUT PUT Relay IN PUT Signal input from voltage conditioner Ground for voltage Zone selective interlock OUT Zone selective interlock IN

E.6

EntelliGuard G
Trip Unit Connection Schemes
Trip Unit - Type GT-S

Trip Unit Connection Schemes

A31

A32

A36

A37

B27

B28

B29

B30

24+

24-

N-RC -

N-RC +

ZSI OUT+

ZSI OUT-

ZSI IN+

ZSI IN-

+24VDC N

ZSI

ZSI

COMMUNICATION TX RX

TX

RX

Intro A

B35

B34

B
Trip Unit - Type GT-N

C
A37 A27 A28 A29 A30 B1 B2 B3 B27 B28 B29 B30

A31

A32

A36

D E

24V+

24V-

N-RC -

N-RC +

RELAY TU 97

P 1

RELAY TU

O/P 2

RELAY I1

IP I2 TU ICOM

ZSI OUT+ + ZSI

ZSI OUT-

ZSI IN+ + ZSI

ZSI IN-

F X

+24VVDC N

98

07

08

SIGNAL INPUT FROM VOLTAGE CONDITIONER V-C V-B V-A GND

COMMUNICATION TX RX

U3

U2

U1

UCOM

TX

RX

B39

B38

B37

B36

B35

B34

E.7

EntelliGuard G
Trip Unit Connection Schemes
Trip Unit - Type GT-H

A27

A28

A29

A30

A31

A32

A36

A37

A38

A39

Wiring DIagrams

RELAY

P 1

RELAY

O/P 2

24V+

24V-

N-RC -

N-RC

ELCT N

TU 97 98 07

TU 08

2+4VVDC N

Intro A B C D
U3

B1

B2

B3

B27

B28

B29

B30

RELAY I1 TU

I/P I2 ICOM

ZSI OUT+

ZSI OUT-

ZSI IN+

ZSI IN-

ZSI

ZSI

SIGNAL INPUT FROM VOLTAGE CONDITIONER V-C V-B V-A GND TX RX

COMMUNICATION TX_EN_I 5V ISO ISO GND

U2

U1

UCOM

TX

RX

EN

5V

E E X
B39 B38 B37 B36 B35 B34 B33 B32 B31

Terminology 24V+/24V-: N-RC: RXD: TXD: TX_EN_I: 5V ISO: ISO GND: ELCT: RELAY O/P: RELAY I/P: V-A/V - B/V-C: GND: ZSI OUT: ZSI IN:

Auxiliary power supply to trip unit Neutral Rogowski coil Modbus/Probus communication Modbus/Probus communication Probus communication Probus communication Probus communication Earth leg CT Relay OUT PUT Relay IN PUT Signal input from voltage conditioner Ground for voltage Zone selective interlock OUT Zone selective interlock IN

E.8

EntelliGuard G

Dimensions F.2 F.3 F.4 F.5 F.6 F.7 F.8 F.10 F.12 F.13 F.14 F.15 Envelope 1 - Fixed Type Envelope 1 - Draw out Type Envelope 2 - Fixed Type Envelope 2 - Draw out Type Envelope 2 - 100% rated type Draw out Type Envelope 1 & 2 - Optional Connection Modes Envelope 3 - Fixed Type Envelope 3 - Draw out Type IP54 Flange, Time Delay Module UVR, 24V Power Supply

The breaker Order Codes Electronic Trip Units Breaker Accessories Application Guide Wiring Diagrams Dimensions Numerical index

Intro A B C D E F X

Rogowskis, Current Transformers, Door Interlock system & wall mounting brackets Interlocking with Cable systems, 2 way Interlocking with Cable systems, 3 way

F.1

EntelliGuard G
Envelope 1 - Fixed Pattern

Front view 4pole


Centre Line of operating panel
423 260

Front view 3pole


Centre Line of operating panel
160

Side view

323

door

Dimensions

Centre Line of operating panel Centre Line of operating panel


50 261 443 131.5 162 172 343 131.5 161 175 211 100 to door 355 91 14

213

213

131.5 162 172

131.5

127

Intro A B
61 100 100 100

Top view 4pole

Top view 3pole

Door Cut Out


308 283

Centre Line of operating panel

183.5

C
A

61

100

100 4 219 150 367

D
100 door

100

door

E F X
20
11

Standard Connection pads

65 22 22
12

Remarks
17

123

A - 6 mounting holes of 9.5mm B - Please refer to section D for clearance distances


35

F.2

107

392

38

348 442

EntelliGuard G
Envelope 1 - Draw out Pattern

Front view 4pole

Front view 3pole

Side view

443

343 172

387 to door

172

Centre Line of operating panel

Centre Line of operating panel

124

173.5

235.5

Centre Line of operating panel


194 194

Centre Line of operating panel

443

Envelope 1

53 131.5 131.5 131.5 131.5

32 Test 52 Disconnected 422 Connected 350 Fully withdrawn

Top view 4pole

Top view 3pole

Door Cut Out

Intro A
Centre Line of operating panel

368

268

308 283

55 31

Centre Line of operating 233.5 panel

Centre Line of operating panel 133.5

55 31

C
183.5
4

B C D

247

267

247

247

150 150

300

6 holes 9.6 58 71.5 58 100 100 100

90

A
58 71.5 100 58 100

90

430

405

E F
Remarks A - 6 mounting holes of 9.5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing

Universal Connection pads Mounted Horizontally or Vertically

Universal Connection pads Details


22.5 20

123

4 holes 12 43

65

2 holes 12

123

15 31 17 8 58

84.5

107

61

61

11

11

43

65

F.3

EntelliGuard G
Envelope 2 - Fixed Pattern

Front view 4pole

Front view 3pole

Side view

540

410

Centre Line of operating panel

319

Centre Line of operating panel

B
190

door

Centre Line of operating panel

Centre Line of operating panel


213

Dimensions

213

50
131.5 222 234 131.5 321 566
131.5 222 234 436 131.5 191

175 211 100 to door 355

91 14

127

Intro A B
76 130 130 130 76 130 130 308 283

Top view 4pole

Top view 3pole

Door Cut Out

C
A A 183.5
4

Centre Line of operating panel

150 150

300

E F
Standard Connection pads

X
20 10 123

95 25 25 25 13 17

Remarks A - 6 mounting holes of 9.5mm B - Please refer to section D for clearance distances

107

35

F.4

430

405

door

door

38

348 442

EntelliGuard G
Envelope 2 - Draw out Pattern

Front view 4pole


573 237

Front view 3pole


443 237

Side view

Centre Line of operating panel

Centre Line of operating panel


D

387 to door

124

194

173.5

235.5

194

443

Centre Line of operating panel

Centre Line of operating panel

Envelope 2

131.5

131.5

131.5

131.5

53

32 Test 52 Disconnected 422 Connected 350 Fully withdrawn

Top view 4pole


488

Top view 3pole


358

Door Cut Out


308 283

55 31

55 31

Centre Line of operating panel

293.5 C

Centre Line of operating 163.5 panel


C 183.5
4

Centre Line of operating panel

Intro A

247

247

267

267

150

300

430

405

B C

90

A 58 91.5 58 130 130 130

A 58 91.5 130 130 58

90

150

D
Universal Connection pads Vertical or Horizontal max. 3200A Universal Connection pads Only Vertical max. 4000A

E F

123

123

107

84.5

64 14 13 25 25 25

61

29 21 21 10 11

62

133

95

Remarks A - 6 mounting holes of 9.5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing

4 holes 13 11 11 100 78 4 holes 11 100 4 holes 13

13 13 25 25 25 15 90

100

78

45

20

4 holes 11

10 59

11

11

78

100

78

F.5

EntelliGuard G
Envelope 2 - 100% rated Draw out Pattern

Front view 4pole

Front view 3pole


443 237

Side view

573 237

Centre Line of operating panel

Centre Line of operating panel


D

387 to door

124

Dimensions

174 236

194

194

131.5

131.5

131.5

131.5

53

32 Test 52 Disconnected 422 350 Fully withdrawn

Top view 4pole

Top view 3pole


358

Door Cut Out


308 283

Intro
55 31

488

A
247

55 31

Centre Line of operating panel

293.5

Centre Line of operating 163.5 panel

Centre Line of operating panel

C 183.5
4

267

247

B C D E F
10 133 11 112 A 90

267

150

300

90

430

58 92

58 130 130 130

150 58 92 58 130 130

Universal Connection pads Vertical max. 4000A

32 21 21

Remarks
100 13 4 holes 11 105 4 holes 13 13

11

11

84

12 58

F.6

25 25 25

A - 6 mounting holes of 9.5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing

105

84

405

443

Centre Line of operating panel

Centre Line of operating panel

EntelliGuard G
Envelope 1 & 2 - Alternate Connection Modes

Fixed Vertical Rear Connection Envelope 1


20

Fixed Front Connection Envelope 1


10 10 10

Draw out Front Connection Envelope 1


10 10 10

100

Envelope 1 and 2

157

453

71

13

63
34.5 31

65 30 25 17

.5 R6

68

96

565

33 10.5 20

65 22 22 12

15 50

13

Intro
Fixed Front Connection Envelope 2 Draw out Front Connection Envelope 2

Fixed Vertical Rear Connection Envelope 2


MAX. 3200A 4000A

A B

12.5 12.5 12.5

12.5 12.5 12.5

100

100

C
453 566

157

157

D E
67.5 100.5 100 12.5 20 25 25 25 12

70.5

70.5

91 130 20 10 10 10

95

13

96 100 12.5 25 25 25 13 17

68.5

F X

130

13 100 25 25 25 25 25 25 100

13

12.5

15

12.5

13

F.7

EntelliGuard G
Envelope 3 - Fixed Type

Front view 4pole

Front view 3pole

945

715 465

Centre Line of operating panel

Centre Line of operating panel

350

Dimensions

Centre Line of operating panel

Centre Line of operating panel

213

213

131.5 479 491 966

131.5 464

131.5 364 376 736

131.5 348

Intro A
Top view 4pole Top view 3pole

B
68.5 115 115 115 115 115 115 115 69 115 115 115 115 115

C
A A 100 100

D E F X

door

door

F.8

EntelliGuard G
Envelope 3 - Fixed Type

Side view

Door Cut Out

308 283

Centre Line of operating panel

348 442

183.5

Envelope 3

219 150

50 175 211 100 to door 355

91 14

127

38

392

367

Intro A
Standard Connection pads Horizontal maximum 5000A Standard Connection pads Vertictal maximum 6400A

B C D

20

120

230 90 20

123

157 60.5

107

E
35

165
88 14 30 30 13
25 25 25

13

F X

17

120

18

Remarks A - 6 mounting holes of 9.5mm B - Please refer to section D for clearance distances

F.9

EntelliGuard G
Envelope 3 - Draw out Pattern

Front view 4pole


973

Front view 3pole


743

Centre Line of operating panel

479

Centre Line of operating panel

364

Centre Line of operating panel

Centre Line of operating panel

Dimensions

194

131.5

131.5

194

131.5

131.5

Top view 4pole

Top view 3pole


654

Intro A
247 55 31

884 639.5

Centre Line of operating panel

434.5 31 244.5 C

524.5

Centre Line of operating panel

319.5 129.5

267

247

55

B C

120

58

58 230 230 230

58 141.5 230 230

58

D E F X

141.5

F.10

120

267

EntelliGuard G
Envelope 3 - Draw out Pattern

Side view

Door Cut Out


308 283

419 to door

Centre Line of operating panel

183.5

D 124

150

300

235.5

430

443

405

Envelope 3

173.5

85

32 Test 52 Disconnected 454 Connected 350 Fully withdrawn

150

Intro A
Standard Connection pads Horizontal maximum 5000A Standard Connection pads Vertictal maximum 6400A
90

B C D E
51

20

55 20

169.5

104

68
12.5 18 102.5 25 25 25 13

70.5

157

100

18

68
25 25 25

F X

13

Remarks A - 6 mounting holes of 9.5mm C - Please leave unobstructed; Required for ventilation D - 1 hole M6 Left & Right for earthing

F.11

EntelliGuard G
IP54 Flange, Time Delay Module UVR, 24V Power Supply

IP54 Flange
5.3 4-Places

IP54 Flange drilling

140

30

474

295.5

Dimensions

22.5

30

283 35.5

386

Centre Line of operating panel

Time delay Module (UVR)

Intro A

Mtg to suit 35mm DIN Rail 79.5

35

90

2 holes 4.5 5.15

B C

42

12

67

5.75

69.5 81

External 24V DC Power Supply

D
4

E
62

Mtg to suit 35mm DIN Rail

F
62 2 holes 5

35

36

73 101

71

F.12

72

405

EntelliGuard G
Rogowskis, Current Transformers, Door Interlock system and Mounting Brackets
Rogowski Coil external Current Transformer external

Arrow to face ACB connection

1D (min) 0D (min) Fix coil to clamp with cable ties (position coil centrally on clamp) HT (max)

Accessories

Rating 400A 630A 2000A 3200A 4000A

1D 94 85 87 84 81 85 85

0D 144 135 151 154 154 198 210

HT 24 30 31 34 57 58 65

58

500A 6400

110

Remark: for ratings > 4000A two coils are used

Intro A B

Door Interlock system


283

183.5

Centre of operating panel B 405

Frame F1-3P F1-4p F2-3P

A 33.5 33.5 98.5 98.5 240.5 355.5

B 32.5 132.5 67.5 197.5 225.5 340.5

C D E F
A B C D E F G H 3 pole 320 159.5 158.5 344 410 189.5 190 437 4 pole 420 259.5 258.5 444 540 319.5 320 567

20

198

4 holes 6.4

F2-4P F3-3P F3-4P

Front mounting brackets (xed pattern, drawings include front connection option)

A F

Centre Line of operating panel

Centre Line of operating panel


B

Centre Line of operating panel


4 holes 12.2 4 holes 12.2

Centre Line of operating panel

131.5 221 234 H

131.5 G

17 102

131.5 159.5 172.5 D

131.5 C

F.13

EntelliGuard G
Interlocking with Cable systems; 2 way

Fixed pattern 2-way cable interlock / Fixed pattern - Front/rear access

2000 max. Envelope 1-3P=320 Envelope 1-4P=420 Envelope 2-3P=410 Envelope 2-4P=540 Envelope 3-3P=715 Envelope 3-4P=945

55

Dimensions

Intro A B C D E F X
Min. bend radius 120

50

50

140 min.

30

30

Min. bend radius 120

Draw out 2-way cable interlock / Withdrawable pattern - Front/rear access

2000 max. Envelope 1-3P=343 Envelope 1-4P=443 Envelope 2-3P=443 Envelope 2-4P=573 Envelope 3-3P=743 Envelope 3-4P=973

60 900 max. vertical base to base 30 30

Min. clearance below cassette 34

Min. clearance below cassette 34 140 min.

40

Min. bend radius 120

Min. bend radius 120

F.14

900 max. vertical base to base

35

EntelliGuard G
Interlocking with Cable systems; 3 way

Fixed pattern 3-way cable interlock / Fixed pattern - Front/rear access

1250 max. Envelope 1-3P=320 Envelope 1-4P=420 Envelope 2-3P=410 Envelope 2-4P=540 Envelope 3-3P=715 Envelope 3-4P=945

55

55

55

900 max. vertical base to base

Accessories

140 min.

Intro A B

Min. bend radius 120

Draw out 3-way cable interlock / Withdrawable pattern - Front/rear access

C D

65

1250 max. Envelope 1-3P=343 Envelope 1-4P=443 Envelope 2-3P=443 Envelope 2-4P=573 Envelope 3-3P=743 Envelope 3-4P=973

65

E F X
140 min. clearence below cassette

30

Min. bend radius 120

F.15

EntelliGuard G
Ref. No. 407 407001 407002 407003 407004 407005 407006 407007 407008 407009 407010 407011 407012 407013 407014 407015 407016 407017 407018 407019 407020 407030 407031 407032 407033 407034 407035 407036 407037 407038 407039 407040 407041 407042 407043 407044 407045 407046 407047 407048 407049 407060 407061 407062 407063 407064 407065 407066 407067 407068 407069 407070 407071 407072 407073 407074 407075 407076 407077 407078 407079 407090 407091 407092 407093 407094 407095 407096 407097 407098 407099 407100 407101 407102 407103 407104 407105 407106 407107 407108 407109 407120 407121 407122 407123 407124 407125 407126 407127 407128 407129 407130 Cat. No. GG04E1 GG04E3 GG04E4 GG04E6 GG04H1 GG04H3 GG04H4 GG04H6 GG04M1 GG04M3 GG04M4 GG04M6 GG04N1 GG04N3 GG04N4 GG04N6 GG04S1 GG04S3 GG04S4 GG04S6 GG07E1 GG07E3 GG07E4 GG07E6 GG07H1 GG07H3 GG07H4 GG07H6 GG07M1 GG07M3 GG07M4 GG07M6 GG07N1 GG07N3 GG07N4 GG07N6 GG07S1 GG07S3 GG07S4 GG07S6 GG08E1 GG08E3 GG08E4 GG08E6 GG08H1 GG08H3 GG08H4 GG08H6 GG08M1 GG08M3 GG08M4 GG08M6 GG08N1 GG08N3 GG08N4 GG08N6 GG08S1 GG08S3 GG08S4 GG08S6 GG10E1 GG10E3 GG10E4 GG10E6 GG10H1 GG10H3 GG10H4 GG10H6 GG10M1 GG10M3 GG10M4 GG10M6 GG10N1 GG10N3 GG10N4 GG10N6 GG10S1 GG10S3 GG10S4 GG10S6 GG13E1 GG13E3 GG13E4 GG13E6 GG13H1 GG13H3 GG13H4 GG13H6 GG13M1 GG13M3 GG13M4 Page A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 Ref. No. 407131 407132 407133 407134 407135 407136 407137 407138 407139 407150 407151 407152 407153 407154 407155 407156 407157 407158 407159 407160 407161 407162 407163 407164 407165 407166 407167 407168 407169 407190 407191 407192 407193 407194 407195 407196 407197 407198 407199 407200 407201 407202 407203 407204 407205 407206 407207 407208 407209 407230 407231 407232 407233 407234 407235 407236 407237 407238 407239 407240 407241 407242 407244 407245 407248 407249 407250 407251 407252 407253 407254 407255 407260 407261 407262 407263 407264 407265 407266 407267 407268 407269 407270 407271 407273 407278 407279 407280 407281 407282 407283 407284 Cat. No. GG13M6 GG13N1 GG13N3 GG13N4 GG13N6 GG13S1 GG13S3 GG13S4 GG13S6 GG16E1 GG16E3 GG16E4 GG16E6 GG16H1 GG16H3 GG16H4 GG16H6 GG16M1 GG16M3 GG16M4 GG16M6 GG16N1 GG16N3 GG16N4 GG16N6 GG16S1 GG16S3 GG16S4 GG16S6 GG20E1 GG20E3 GG20E4 GG20E6 GG20H1 GG20H3 GG20H4 GG20H6 GG20M1 GG20M3 GG20M4 GG20M6 GG20N1 GG20N3 GG20N4 GG20N6 GG20S1 GG20S3 GG20S4 GG20S6 GG25H1 GG25H3 GG25H4 GG25H6 GG25M1 GG25M3 GG25M4 GG25M6 GG25N1 GG25N3 GG25N4 GG25N6 GG32H1 GG32H4 GG32H6 GG32L1 GG32L3 GG32G1 GG32G3 GG32G4 GG32G6 GG32L4 GG32L6 GG32M1 GG32M3 GG32M4 GG32M6 GG32N1 GG32N3 GG32N4 GG32N6 GG40G1 GG40G3 GG40G4 GG40G6 GG32H3 GG40H1 GG40H3 GG40H4 GG40H6 GG40L1 GG40L3 GG40L4 Page A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.4 A.4 A.8 A.8 A.8 A.8 A.4 A.4 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.8 A.4 A.4 A.8 A.8 A.4 Ref. No. 407285 407286 407287 407288 407289 407290 407291 407292 407293 407300 407301 407302 407303 407304 407305 407306 407307 407320 407321 407322 407323 407324 407325 407326 407327 407346 407347 407348 407349 407350 407351 407352 407353 407354 407355 407356 407357 407374 407375 407376 407377 407378 407379 407380 407381 407394 407395 407396 407397 407398 407399 407400 407401 407414 407415 407416 407417 407418 407419 407420 407421 407434 407435 407436 407437 407438 407439 407440 407441 407454 407455 407456 407457 407458 407459 407460 407461 407474 407475 407476 407477 407478 407479 407480 407481 407494 407495 407496 407497 407498 407499 407500 Cat. No. GG40L6 GG40M1 GG40M3 GG40M4 GG40M6 GG40N1 GG40N3 GG40N4 GG40N6 GG50L1 GG50L3 GG50L4 GG50L6 GG50M1 GG50M3 GG50M4 GG50M6 GG64L1 GG64L3 GG44L4 GG64L6 GG64M1 GG64M3 GG44M4 GG64M6 GH32H1 GH32H3 GH32M1 GH32M3 GH32N1 GH32N3 GH40H1 GH40H3 GH40M1 GH40M3 GH40N1 GH40N3 GW04N1 GW04N3 GW04N4 GW04N6 GJ04S1 GJ04S3 GJ04S4 GJ04S6 GW07N1 GW07N3 GW07N4 GW07N6 GJ07S1 GJ07S3 GJ07S4 GJ07S6 GW08N1 GW08N3 GW08N4 GW08N6 GJ08S1 GJ08S3 GJ08S4 GJ08S6 GW10N1 GW10N3 GW10N4 GW10N6 GJ10S1 GJ10S3 GJ10S4 GJ10S6 GW13N1 GW13N3 GW13N4 GW13N6 GJ13S1 GJ13S3 GJ13S4 GJ13S6 GW16N1 GW16N3 GW16N4 GW16N6 GJ16S1 GJ16S3 GJ16S4 GJ16S6 GW20N1 GW20N3 GW20N4 GW20N6 GJ20S1 GJ20S3 GJ20S4

By reference number
Page A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.9 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 Ref. No. 407501 407518 407519 407520 407521 407533 407534 407535 407536 407537 407538 407539 407540 407554 407555 407556 407557 407558 407559 407560 407561 407565 407566 407567 407568 407575 407576 407577 407578 407589 407590 407591 407592 407593 407594 407595 407596 407600 407602 407603 407605 407606 407607 407610 407612 407613 407615 407620 407622 407623 407625 407630 407633 407635 407636 407637 407640 407642 407643 407645 407650 407652 407654 407656 407658 407668 407670 407679 407680 407686 407688 407690 407692 407693 407695 407700 407701 407702 407703 407704 407705 407706 407707 407708 407709 407710 407711 407712 407713 407714 407715 407716 Cat. No. GJ20S6 GJ25N1 GJ25N3 GJ25N4 GJ25N6 GJ32L1 GJ32L3 GJ32L4 GJ32L6 GJ32N1 GJ32N3 GJ32N4 GJ32N6 GJ40L1 GJ40L3 GJ40L4 GJ40L6 GJ40N1 GJ40N3 GJ40N4 GJ40N6 GJ50L1 GJ50L3 GJ50L4 GJ50L6 GJ64L1 GJ64L3 GJ64L4 GJ64L6 GZ32H1 GZ32H3 GK32N1 GK32N3 GZ40H1 GZ40H3 GK40N1 GK40N3 GG13H2F-R GG13H2U-R GG13H5F-R GG13H5U-R G20H2SSL G20H5SSL GG16H2F-R GG16H2U-R GG16H5F-R GG16H5U-R GG20H2F-R GG20H2U-R GG20H5F-R GG20H5U-R GG20M2F-R GG20M5F-R GG20M5U-R G40M2SSL G40M5SSL GG25M2F-R GG25M2U-R GG25M5F-R GG25M5U-R GG32M2F-R GG32M2U-R GG32M5F-R GG32M5U-R GG40M2F-R GG40M5F-R GG40M5U-R G64L2SSL G64L5SSL GG64L2U-R GG64L5U-R GG13H2FM GG13H2UM GG13H5F_M GG13H5UM GM01024D GM01024DR GM01048D GM01048DR GM01060D GM01060DR GM01110D GM01110DR GM01250D GM01250DR GM01048A GM01048AR GM01120A GM01120AR GM01240A GM01240AR GM01400A Page A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.25 A.25 A.25 A.25 A.28 A.28 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.28 A.28 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.25 A.28 A.28 A.25 A.25 A.11 A.11 A.11 A.11 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17

Intro A B C D E F X

Numerical index
X.1

EntelliGuard G
Ref. No. 407717 407718 407719 407725 407726 407727 407728 407729 407730 407731 407732 407733 407734 407735 407736 407737 407738 407739 407740 407741 407742 407743 407744 407753 407754 407770 407771 407772 407773 407774 407775 407776 407777 407778 407779 407780 407781 407782 407783 407784 407785 407795 407796 407797 407798 407799 407800 407801 407802 407803 407804 407805 407806 407807 407808 407809 407810 407816 407817 407818 407819 407820 407821 407822 407823 407824 407825 407835 407836 407837 407838 407839 407840 407841 407842 407843 407844 407849 407850 407851 407852 407853 407854 407860 407861 407862 407863 407864 407865 407866 407867 407868 Cat. No. GM01400AR GM01440A GM01440AR GM02024D GM02024DR GM02048D GM02048DR GM02060D GM02060DR GM02110D GM02110DR GM02250D GM02250DR GM02048A GM02048AR GM02120A GM02120AR GM02240A GM02240AR GM02400A GM02400AR GM02440A GM02440AR GNTK120 GNTK240 GSTR024D GSTR024DR GSTR048 GSTR048R GSTR060D GSTR060DR GSTR120 GSTR120R GSTR240 GSTR240R GSTR277 GSTR277R GSTR400A GSTR400AR GSTR440A GSTR440AR GUVT024D GUVT024DR GUVT048 GUVT048R GUVT060D GUVT060DR GUVT120 GUVT120R GUVT240 GUVT240R GUVT277 GUVT277R GUVT400A GUVT400AR GUVT440A GUVT440AR GTDM048A GTDM060D GTDM120A GTDM120D GTDM240A GTDM240D GTDM277A GTDM250D GTDM400A GTDM440A GCCC024DR GCCC024D GCCC048R GCCC048 GCCC060DR GCCC060D GCCC120R GCCC120 GCCC240R GCCC240 GCCC277 GCCC277R GCCC400AR GCCC400A GCCC440A GCCC440AR GCCN024DR GCCN024D GCCN048R GCCN048 GCCN060DR GCCN060D GCCN120R GCCN120 GCCN240R Page A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.17 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.17 A.20 A.20 A.17 A.17 A.20 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 Ref. No. 407869 407870 407871 407876 407877 407878 407879 407880 407881 407882 407883 407886 407887 407888 407889 407891 407894 407895 407896 407897 407899 407900 407901 407902 407903 407904 407905 407906 407907 407915 407916 407922 407923 407924 407925 407930 407931 407932 407933 407934 407935 407936 407937 407967 407968 407970 407971 407974 407976 407978 407979 407980 407981 407984 407985 407986 407987 407990 407991 407992 407993 407994 407995 407996 407999 408 408000 408001 408002 408003 408004 408005 408006 408025 408026 408028 408029 408033 408035 408036 408038 408039 408040 408041 408042 408043 408045 408046 408047 408049 408052 408054 Cat. No. GCCN240 GCCN277 GCCN277R GCCN400AR GCCN400A GCCN440A GCCN440AR GAUX3R GAUX5R GAUX6R GAUX8R GAUX5 GAUX6 GAUX8 GBAT1R GBAT1 GRTC3 GCSP1 GCSP2 GRTC1 GRTC2 GI2FAD GI2WAD GI3FB GI3WB GI3FC GI3WC GI3FDT GI3WDT GCSP1R GCSP2R GCPS1 GCPS2 GCPS1R GCPS2R G16H4ED G16H6ED G20H4ED G20H6ED G40M4ED G40M6ED G64M4ED G64M6ED GBCASR GBRONR GBCAS GBRON GCRONR GCRON GBPRO GBPROR GCPRO GCPROR GRONCS GRON GCAS GPRO GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 GTUTK20 G04HNRC G07HNRC G08HNRC G10HNRC G13HNRC G16HNRC G20HNRC GDPRF GDPRW GFA4 GFA6 GMCNR GMCN GCNTW G54DR GLHD GPBD GREPM GRHD GRHN GLTK GTUS GUNI GLTA GSDFTR GSDWTR Page A.17 A.17 A.20 A.20 A.17 A.17 A.20 A.20 A.20 A.20 A.20 A.17 A.17 A.17 A.20 A.17 A.17 A.17 A.17 A.17 A.17 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.20 A.20 A.17 A.17 A.20 A.20 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.21 A.21 A.18 A.18 A.21 A.18 A.18 A.21 A.18 A.21 A.28 A.21 A.21 A.21 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.23 A.23 A.28 A.28 A.21 A.18 A.23 A.23 A.23 A.23 A.23 A.23 A.28 A.23 A.22 A.28 A.23 A.28 A.28 Ref. No. 408057 408060 408061 408062 408063 408064 408065 408066 408067 408068 408069 408070 408071 408072 408073 408074 408075 408085 408097 408098 408100 408102 408103 408104 408106 408109 408117 408120 408131 408144 408145 408148 408162 408169 408172 408186 408187 408188 408189 408193 408200 408202 408203 408205 408210 408212 408213 408215 408222 408224 408225 408227 408234 408236 408237 408239 408245 408247 408249 408251 408254 408255 408257 408259 408261 408263 408267 408268 408281 408283 408292 408293 408294 408295 408300 408301 408302 408303 408304 408305 408306 408322 408331 408332 408333 408334 408350 408351 408352 408353 408354 408355 Cat. No. GJP G16H4FFI G20H4FFI G16H6FFI G20H6FFI G20H4RVI G20H6RVI G32M4FFI G40M4FFI G32M6FFI G40M6FFI G32M4RVI G32M6RVI G40M4RVI G64L4RVI G40M6RVI G64L6RVI GFMTG G13HCLS G20HARC G16HCLS G20HCHT G20HCLS G20NARC G20MCLS G25MCLS G32MCLS G40MCLS G40MCHT G64LCHT G50LCLS G64LCLS G25MNRC G40MARC G40NARC G32LNRC G40LNRC G50LNRC G64LNRC G64LARC GG16H2FM GG16H2UM GG16H5FM GG16H5UM GG20H2FM GG20H2UM GG20H5FM GG20H5UM GG20M2FM GG20M2UM GG20M5FM GG20M5UM GG25M2FM GG25M2UM GG25M5FM GG25M5UM GG32M2FM GG32M2UM GG32M5FM GG32M5UM GH32M2VRM GH32M5VR.M GG40M2FM GG40M2UM GG40M5FM GG40M5UM GH40M2VRM GH40M5VRM GG64L2UM GG64L5UM GH32M2VM GH32M5VM GH40M2VM GH40M5VM G04HNCT G07HNCT G08HNCT G10HNCT G13HNCT G16HNCT G20HNCT G25MNCT G32LNCT G40LNCT G50LNCT G64LNCT GW04M4 GW04M6 GW07M4 GW07M6 GW08M4 GW08M6 Page A.23 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.6 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.28 A.24 A.28 A.28 A.24 A.24 A.24 A.24 A.28 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.11 A.25 A.25 A.11 A.11 A.11 A.11 A.25 A.25 A.11 A.11 A.11 A.11 A.11 A.11 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.5 A.5 A.5 A.5 A.5 A.5 Ref. No. 408356 408357 408358 408359 408360 408361 408362 408363 408364 408365 408366 408367 408368 408369 408400 408401 408402 408403 408404 408405 408406 408407 408408 408409 408410 408411 408412 408413 408414 408415 408416 408417 408418 408419 408789 408790 408791 408792 408796 408800 408801 408802 408803 408805 408806 408807 408808 408809 408813 408815 408816 408817 408818 408819 408823 408825 408826 408827 408828 408829 408830 408831 408832 408833 408834 408835 408836 408837 408838 408839 408840 408841 408842 408843 408844 408845 408846 408847 408848 408849 408850 408851 408852 408853 408854 408855 408856 408860 408863 408865 Cat. No. GW10M4 GW10M6 GW13M4 GW13M6 GW16M4 GW16M6 GW20M4 GW20M6 GW25M4 GW25M6 GW32M4 GW32M6 GW40M4 GW40M6 GW04M1 GW04M3 GW07M1 GW07M3 GW08M1 GW08M3 GW10M1 GW10M3 GW13M1 GW13M3 GW16M1 GW16M3 GW20M1 GW20M3 GW25M1 GW25M3 GW32M1 GW32M3 GW40M1 GW40M3 GAPU GMPU1 GMPU2 GMPU3 G3G00KA-SR GTG00K1-SF GTG00K2-SF GTG00K2-SR GTG00K9-SR GTG00K3-SF GTG00K4-SF GTG00K3-2SF GTG00K4-2SF GTG00K4-2SR GTG00K9-4SF GTG00K3-4SF GTG00K4-4SF GTG00K3T6SF GTG00K4T6SF GTG00K4T6SR GTG00N9-5SF GTG00N5-5SF GTG00N6-5SF GTG00N7-5SF GTG00N8-5SF GTG00N5T5SF GTG00N6T5SF GTG00N7T5SF GTG00N8T5SF GTG00N5-8SF GTG00N6-8SF GTG00N7-8SF GTG00N8-8SF GTG00N5T8SF GTG00N6T8SF GTG00N7T8SF GTG00N8T8SF GTG00N5-9SF GTG00N6-9SF GTG00N7-9SF GTG00N8-9SF GTG00N5T9SF GTG00N6T9SF GTG00N7T9SF GTG00N8T9SF GTG00N5T8SR GTG00N6T8SR GTG00N7T8SR GTG00N8T8SR GTG00N5T9SR GTG00N6T9SR GTG00N7T9SR GTG00N8T9SR GTPUNI GTG00N9-8SF GTG00N9-9SF Page A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.5 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.10 A.22 A.22 A.22 A.22 A.27 A.12 A.12 A.26 A.12 A.12 A.12 A.12 A.12 A.26 A.13 A.13 A.13 A.13 A.13 A.26 A.14 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.14 A.16 A.15 A.16 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.27 A.12 A.14 A.14

Intro A B C D E F X

X.2

By reference number

EntelliGuard G
Cat. No. G G04HNCT G04HNRC G07HNCT G07HNRC G08HNCT G08HNRC G10HNCT G10HNRC G13HCLS G13HNCT G13HNRC G16H4ED G16H4FFI G16H6ED G16H6FFI G16HCLS G16HNCT G16HNRC G20H2SSL G20H4ED G20H4FFI G20H4RVI G20H5SSL G20H6ED G20H6FFI G20H6RVI G20HARC G20HCHT G20HCLS G20HNCT G20HNRC G20MCLS G20NARC G25MCLS G25MNCT G25MNRC G32LNCT G32LNRC G32M4FFI G32M4RVI G32M6FFI G32M6RVI G32MCLS G3G00KA-SR G40LNCT G40LNRC G40M2SSL G40M4ED G40M4FFI G40M4RVI G40M5SSL G40M6ED G40M6FFI G40M6RVI G40MARC G40MCHT G40MCLS G40NARC G50LCLS G50LNCT G50LNRC G54DR G64L2SSL G64L4RVI G64L5SSL G64L6RVI G64LARC G64LCHT G64LCLS G64LNCT G64LNRC G64M4ED G64M6ED GA GAPU GAUX3R GAUX5 GAUX5R GAUX6 GAUX6R GAUX8 GAUX8R GB GBAT1 GBAT1R GBCAS GBCASR GBPRO GBPROR GBRON Ref. No. 408300 408000 408301 408001 408302 408002 408303 408003 408097 408304 408004 407930 408060 407931 408062 408100 408305 408005 407606 407932 408061 408064 407607 407933 408063 408065 408098 408102 408103 408306 408006 408106 408104 408109 408322 408162 408331 408186 408066 408070 408068 408071 408117 408796 408332 408187 407636 407934 408067 408072 407637 407935 408069 408074 408169 408131 408120 408172 408145 408333 408188 408038 407679 408073 407680 408075 408193 408144 408148 408334 408189 407936 407937 408789 407880 407886 407881 407887 407882 407888 407883 407891 407889 407970 407967 407978 407979 407971 Page A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.24 A.28 A.24 A.24 A.22 A.6 A.22 A.6 A.28 A.24 A.24 A.28 A.22 A.6 A.6 A.28 A.22 A.6 A.6 A.28 A.28 A.28 A.24 A.24 A.28 A.28 A.28 A.24 A.24 A.24 A.24 A.6 A.6 A.6 A.6 A.28 A.27 A.24 A.24 A.28 A.22 A.6 A.6 A.28 A.22 A.6 A.6 A.28 A.28 A.28 A.28 A.28 A.24 A.24 A.23 A.28 A.6 A.28 A.6 A.28 A.28 A.28 A.24 A.24 A.22 A.22 A.22 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.18 A.21 A.18 A.21 A.18 Cat. No. GBRONR GC GCAS GCB1 GCB2 GCB3 GCB4 GCB5 GCB6 GCB7 GCCC024D GCCC024DR GCCC048 GCCC048R GCCC060D GCCC060DR GCCC120 GCCC120R GCCC240 GCCC240R GCCC277 GCCC277R GCCC400A GCCC400AR GCCC440A GCCC440AR GCCN024D GCCN024DR GCCN048 GCCN048R GCCN060D GCCN060DR GCCN120 GCCN120R GCCN240 GCCN240R GCCN277 GCCN277R GCCN400A GCCN400AR GCCN440A GCCN440AR GCNTW GCPRO GCPROR GCPS1 GCPS1R GCPS2 GCPS2R GCRON GCRONR GCSP1 GCSP1R GCSP2 GCSP2R GD GDPRF GDPRW GF GFA4 GFA6 GFMTG GG GG04E1 GG04E3 GG04E4 GG04E6 GG04H1 GG04H3 GG04H4 GG04H6 GG04M1 GG04M3 GG04M4 GG04M6 GG04N1 GG04N3 GG04N4 GG04N6 GG04S1 GG04S3 GG04S4 GG04S6 GG07E1 GG07E3 GG07E4 GG07E6 GG07H1 GG07H3 GG07H4 GG07H6 Ref. No. 407968 407986 407990 407991 407992 407993 407994 407995 407996 407836 407835 407838 407837 407840 407839 407842 407841 407844 407843 407849 407850 407852 407851 407853 407854 407861 407860 407863 407862 407865 407864 407867 407866 407869 407868 407870 407871 407877 407876 407878 407879 408036 407980 407981 407922 407924 407923 407925 407976 407974 407895 407915 407896 407916 408025 408026 408028 408029 408085 407001 407002 407003 407004 407005 407006 407007 407008 407009 407010 407011 407012 407013 407014 407015 407016 407017 407018 407019 407020 407030 407031 407032 407033 407034 407035 407036 407037 Page A.21 A.21 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.23 A.18 A.21 A.17 A.20 A.17 A.20 A.18 A.21 A.17 A.20 A.17 A.20 A.23 A.23 A.28 A.28 A.6 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 Cat. No. GG07M1 GG07M3 GG07M4 GG07M6 GG07N1 GG07N3 GG07N4 GG07N6 GG07S1 GG07S3 GG07S4 GG07S6 GG08E1 GG08E3 GG08E4 GG08E6 GG08H1 GG08H3 GG08H4 GG08H6 GG08M1 GG08M3 GG08M4 GG08M6 GG08N1 GG08N3 GG08N4 GG08N6 GG08S1 GG08S3 GG08S4 GG08S6 GG10E1 GG10E3 GG10E4 GG10E6 GG10H1 GG10H3 GG10H4 GG10H6 GG10M1 GG10M3 GG10M4 GG10M6 GG10N1 GG10N3 GG10N4 GG10N6 GG10S1 GG10S3 GG10S4 GG10S6 GG13E1 GG13E3 GG13E4 GG13E6 GG13H1 GG13H2F-R GG13H2FM GG13H2U-R GG13H2UM GG13H3 GG13H4 GG13H5F_M GG13H5F-R GG13H5U-R GG13H5UM GG13H6 GG13M1 GG13M3 GG13M4 GG13M6 GG13N1 GG13N3 GG13N4 GG13N6 GG13S1 GG13S3 GG13S4 GG13S6 GG16E1 GG16E3 GG16E4 GG16E6 GG16H1 GG16H2F-R GG16H2FM GG16H2U-R GG16H2UM GG16H3 GG16H4 Ref. No. 407038 407039 407040 407041 407042 407043 407044 407045 407046 407047 407048 407049 407060 407061 407062 407063 407064 407065 407066 407067 407068 407069 407070 407071 407072 407073 407074 407075 407076 407077 407078 407079 407090 407091 407092 407093 407094 407095 407096 407097 407098 407099 407100 407101 407102 407103 407104 407105 407106 407107 407108 407109 407120 407121 407122 407123 407124 407600 407690 407602 407692 407125 407126 407693 407603 407605 407695 407127 407128 407129 407130 407131 407132 407133 407134 407135 407136 407137 407138 407139 407150 407151 407152 407153 407154 407610 408200 407612 408202 407155 407156

By catalogue number
Page A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.25 A.11 A.8 A.4 A.11 A.25 A.25 A.11 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.25 A.11 A.8 A.4 Cat. No. GG16H5F-R GG16H5FM GG16H5U-R GG16H5UM GG16H6 GG16M1 GG16M3 GG16M4 GG16M6 GG16N1 GG16N3 GG16N4 GG16N6 GG16S1 GG16S3 GG16S4 GG16S6 GG20E1 GG20E3 GG20E4 GG20E6 GG20H1 GG20H2F-R GG20H2FM GG20H2U-R GG20H2UM GG20H3 GG20H4 GG20H5F-R GG20H5FM GG20H5U-R GG20H5UM GG20H6 GG20M1 GG20M2F-R GG20M2FM GG20M2UM GG20M3 GG20M4 GG20M5F-R GG20M5FM GG20M5U-R GG20M5UM GG20M6 GG20N1 GG20N3 GG20N4 GG20N6 GG20S1 GG20S3 GG20S4 GG20S6 GG25H1 GG25H3 GG25H4 GG25H6 GG25M1 GG25M2F-R GG25M2FM GG25M2U-R GG25M2UM GG25M3 GG25M4 GG25M5F-R GG25M5FM GG25M5U-R GG25M5UM GG25M6 GG25N1 GG25N3 GG25N4 GG25N6 GG32G1 GG32G3 GG32G4 GG32G6 GG32H1 GG32H3 GG32H4 GG32H6 GG32L1 GG32L3 GG32L4 GG32L6 GG32M1 GG32M2F-R GG32M2FM GG32M2U-R GG32M2UM GG32M3 GG32M4 Ref. No. 407613 408203 407615 408205 407157 407158 407159 407160 407161 407162 407163 407164 407165 407166 407167 407168 407169 407190 407191 407192 407193 407194 407620 408210 407622 408212 407195 407196 407623 408213 407625 408215 407197 407198 407630 408222 408224 407199 407200 407633 408225 407635 408227 407201 407202 407203 407204 407205 407206 407207 407208 407209 407230 407231 407232 407233 407234 407640 408234 407642 408236 407235 407236 407643 408237 407645 408239 407237 407238 407239 407240 407241 407250 407251 407252 407253 407242 407273 407244 407245 407248 407249 407254 407255 407260 407650 408245 407652 408247 407261 407262 Page A.25 A.11 A.25 A.11 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.25 A.11 A.8 A.4 A.25 A.11 A.25 A.11 A.4 A.8 A.25 A.11 A.11 A.8 A.4 A.25 A.11 A.25 A.11 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.25 A.11 A.8 A.4 A.25 A.11 A.25 A.11 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.25 A.11 A.8 A.4

Intro A B C D E F X

Numerical index
X.3

EntelliGuard G
Cat. No. GG32M5F-R GG32M5FM GG32M5U-R GG32M5UM GG32M6 GG32N1 GG32N3 GG32N4 GG32N6 GG40G1 GG40G3 GG40G4 GG40G6 GG40H1 GG40H3 GG40H4 GG40H6 GG40L1 GG40L3 GG40L4 GG40L6 GG40M1 GG40M2F-R GG40M2FM GG40M2UM GG40M3 GG40M4 GG40M5F-R GG40M5FM GG40M5U-R GG40M5UM GG40M6 GG40N1 GG40N3 GG40N4 GG40N6 GG44L4 GG44M4 GG50L1 GG50L3 GG50L4 GG50L6 GG50M1 GG50M3 GG50M4 GG50M6 GG64L1 GG64L2U-R GG64L2UM GG64L3 GG64L5U-R GG64L5UM GG64L6 GG64M1 GG64M3 GG64M6 GH GH32H1 GH32H3 GH32M1 GH32M2VM GH32M2VRM GH32M3 GH32M5VM GH32M5VR.M GH32N1 GH32N3 GH40H1 GH40H3 GH40M1 GH40M2VM GH40M2VRM GH40M3 GH40M5VM GH40M5VRM GH40N1 GH40N3 GI GI2FAD GI2WAD GI3FB GI3FC GI3FDT GI3WB GI3WC GI3WDT GJ GJ04S1 GJ04S3 GJ04S4 GJ04S6 Ref. No. 407654 408249 407656 408251 407263 407264 407265 407266 407267 407268 407269 407270 407271 407278 407279 407280 407281 407282 407283 407284 407285 407286 407658 408257 408259 407287 407288 407668 408261 407670 408263 407289 407290 407291 407292 407293 407322 407326 407300 407301 407302 407303 407304 407305 407306 407307 407320 407686 408281 407321 407688 408283 407323 407324 407325 407327 407346 407347 407348 408292 408254 407349 408293 408255 407350 407351 407352 407353 407354 408294 408267 407355 408295 408268 407356 407357 407900 407901 407902 407904 407906 407903 407905 407907 407378 407379 407380 407381 Page A.25 A.11 A.25 A.11 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.11 A.8 A.4 A.25 A.11 A.25 A.11 A.4 A.8 A.8 A.4 A.4 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.8 A.4 A.4 A.8 A.25 A.11 A.8 A.25 A.11 A.4 A.8 A.8 A.4 A.9 A.9 A.9 A.11 A.25 A.9 A.11 A.25 A.9 A.9 A.9 A.9 A.9 A.11 A.25 A.9 A.11 A.25 A.9 A.9 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.18 A.10 A.10 A.5 A.5 Cat. No. GJ07S1 GJ07S3 GJ07S4 GJ07S6 GJ08S1 GJ08S3 GJ08S4 GJ08S6 GJ10S1 GJ10S3 GJ10S4 GJ10S6 GJ13S1 GJ13S3 GJ13S4 GJ13S6 GJ16S1 GJ16S3 GJ16S4 GJ16S6 GJ20S1 GJ20S3 GJ20S4 GJ20S6 GJ25N1 GJ25N3 GJ25N4 GJ25N6 GJ32L1 GJ32L3 GJ32L4 GJ32L6 GJ32N1 GJ32N3 GJ32N4 GJ32N6 GJ40L1 GJ40L3 GJ40L4 GJ40L6 GJ40N1 GJ40N3 GJ40N4 GJ40N6 GJ50L1 GJ50L3 GJ50L4 GJ50L6 GJ64L1 GJ64L3 GJ64L4 GJ64L6 GJP GK GK32N1 GK32N3 GK40N1 GK40N3 GL GLHD GLTA GLTK GM GM01024D GM01024DR GM01048A GM01048AR GM01048D GM01048DR GM01060D GM01060DR GM01110D GM01110DR GM01120A GM01120AR GM01240A GM01240AR GM01250D GM01250DR GM01400A GM01400AR GM01440A GM01440AR GM02024D GM02024DR GM02048A GM02048AR GM02048D GM02048DR GM02060D GM02060DR Ref. No. 407398 407399 407400 407401 407418 407419 407420 407421 407438 407439 407440 407441 407458 407459 407460 407461 407478 407479 407480 407481 407498 407499 407500 407501 407518 407519 407520 407521 407533 407534 407535 407536 407537 407538 407539 407540 407554 407555 407556 407557 407558 407559 407560 407561 407565 407566 407567 407568 407575 407576 407577 407578 408057 407591 407592 407595 407596 408039 408049 408045 407700 407701 407710 407711 407702 407703 407704 407705 407706 407707 407712 407713 407714 407715 407708 407709 407716 407717 407718 407719 407725 407726 407735 407736 407727 407728 407729 407730 Page A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.23 A.10 A.10 A.10 A.10 A.23 A.23 A.23 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 Cat. No. GM02110D GM02110DR GM02120A GM02120AR GM02240A GM02240AR GM02250D GM02250DR GM02400A GM02400AR GM02440A GM02440AR GMCN GMCNR GMPU1 GMPU2 GMPU3 GN GNTK120 GNTK240 GP GPBD GPRO GR GREPM GRHD GRHN GRON GRONCS GRTC1 GRTC2 GRTC3 GS GSDFTR GSDWTR GSTR024D GSTR024DR GSTR048 GSTR048R GSTR060D GSTR060DR GSTR120 GSTR120R GSTR240 GSTR240R GSTR277 GSTR277R GSTR400A GSTR400AR GSTR440A GSTR440AR GT GTDM048A GTDM060D GTDM120A GTDM120D GTDM240A GTDM240D GTDM250D GTDM277A GTDM400A GTDM440A GTG00K1-SF GTG00K2-SF GTG00K2-SR GTG00K3-2SF GTG00K3-4SF GTG00K3-SF GTG00K3T6SF GTG00K4-2SF GTG00K4-2SR GTG00K4-4SF GTG00K4-SF GTG00K4T6SF GTG00K4T6SR GTG00K9-4SF GTG00K9-SR GTG00N5-5SF GTG00N5-8SF GTG00N5-9SF GTG00N5T5SF GTG00N5T8SF GTG00N5T8SR GTG00N5T9SF GTG00N5T9SR GTG00N6-5SF GTG00N6-8SF GTG00N6-9SF GTG00N6T5SF GTG00N6T8SF GTG00N6T8SR Ref. No. 407731 407732 407737 407738 407739 407740 407733 407734 407741 407742 407743 407744 408035 408033 408790 408791 408792 407753 407754 408040 407987 408041 408042 408043 407985 407984 407897 407899 407894 408052 408054 407770 407771 407772 407773 407774 407775 407776 407777 407778 407779 407780 407781 407782 407783 407784 407785 407816 407817 407818 407819 407820 407821 407823 407822 407824 407825 408800 408801 408802 408807 408815 408805 408817 408808 408809 408816 408806 408818 408819 408813 408803 408825 408833 408841 408829 408837 408849 408845 408853 408826 408834 408842 408830 408838 408850 Page A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.18 A.21 A.22 A.22 A.22 A.17 A.17 A.23 A.21 A.23 A.23 A.28 A.21 A.28 A.17 A.17 A.17 A.28 A.28 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.22 A.12 A.12 A.26 A.12 A.13 A.12 A.13 A.12 A.26 A.13 A.12 A.13 A.26 A.13 A.12 A.14 A.14 A.14 A.14 A.14 A.27 A.14 A.27 A.16 A.16 A.16 A.16 A.16 A.27 Cat. No. GTG00N6T9SF GTG00N6T9SR GTG00N7-5SF GTG00N7-8SF GTG00N7-9SF GTG00N7T5SF GTG00N7T8SF GTG00N7T8SR GTG00N7T9SF GTG00N7T9SR GTG00N8-5SF GTG00N8-8SF GTG00N8-9SF GTG00N8T5SF GTG00N8T8SF GTG00N8T8SR GTG00N8T9SF GTG00N8T9SR GTG00N9-5SF GTG00N9-8SF GTG00N9-9SF GTPUNI GTUS GTUTK20 GU GUNI GUVT024D GUVT024DR GUVT048 GUVT048R GUVT060D GUVT060DR GUVT120 GUVT120R GUVT240 GUVT240R GUVT277 GUVT277R GUVT400A GUVT400AR GUVT440A GUVT440AR GW GW04M1 GW04M3 GW04M4 GW04M6 GW04N1 GW04N3 GW04N4 GW04N6 GW07M1 GW07M3 GW07M4 GW07M6 GW07N1 GW07N3 GW07N4 GW07N6 GW08M1 GW08M3 GW08M4 GW08M6 GW08N1 GW08N3 GW08N4 GW08N6 GW10M1 GW10M3 GW10M4 GW10M6 GW10N1 GW10N3 GW10N4 GW10N6 GW13M1 GW13M3 GW13M4 GW13M6 GW13N1 GW13N3 GW13N4 GW13N6 GW16M1 GW16M3 GW16M4 GW16M6 GW16N1 GW16N3 GW16N4 GW16N6 Ref. No. 408846 408854 408827 408835 408843 408831 408839 408851 408847 408855 408828 408836 408844 408832 408840 408852 408848 408856 408823 408863 408865 408860 408046 407999 408047 407795 407796 407797 407798 407799 407800 407801 407802 407803 407804 407805 407806 407807 407808 407809 407810 408400 408401 408350 408351 407374 407375 407376 407377 408402 408403 408352 408353 407394 407395 407396 407397 408404 408405 408354 408355 407414 407415 407416 407417 408406 408407 408356 408357 407434 407435 407436 407437 408408 408409 408358 408359 407454 407455 407456 407457 408410 408411 408360 408361 407474 407475 407476 407477 Page A.16 A.27 A.15 A.15 A.15 A.15 A.15 A.27 A.15 A.27 A.16 A.16 A.16 A.16 A.16 A.27 A.16 A.27 A.14 A.14 A.14 A.12 A.22 A.22 A.28 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.17 A.20 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5

Intro A B C D E F X

X.4

By catalogue number

EntelliGuard G
Cat. No. GW20M1 GW20M3 GW20M4 GW20M6 GW20N1 GW20N3 GW20N4 GW20N6 GW25M1 GW25M3 GW25M4 GW25M6 GW32M1 GW32M3 GW32M4 GW32M6 GW40M1 GW40M3 GW40M4 GW40M6 GZ GZ32H1 GZ32H3 GZ40H1 GZ40H3 Ref. No. 408412 408413 408362 408363 407494 407495 407496 407497 408414 408415 408364 408365 408416 408417 408366 408367 408418 408419 408368 408369 407589 407590 407593 407594 Page A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.5 A.5 A.10 A.10 A.10 A.10

Intro A B C D E F X

Numerical index

The policy of GE Consumer & Industrial is one of continuous improvement. The right is reserved to alter the design or any structural details of the products at any time without giving notice. February 2009 GE Consumer & Industrial

X.5

GE Consumer & Industrial Power Protection

Power Protection (formerly GE Power Controls), a division of GE Consumer & Industrial, is a rst class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the companys products comes from wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide.

www.ge.com/eu/powerprotection www.ge.com/ex/powerprotection

GE POWER CONTROLS Ltd 129-135 Camp Road St Albans Herts AL1 5HL United Kingdom Customer Service Tel. 0800 587 1251 Fax 0800 587 1239 E-mail: gepcuk@gepc.ge.com

GE CONSUMER & INDUSTRIAL HUNGARY Vci t 77 H-1340 Budapest Hungary Customer Service Tel. +361 447 6046 Fax +361 447 5060 E-mail: mea.export .consind@ge.com Net: www.gepowershop.com

GE CONSUMER & INDUSTRIAL POWER PROTECTION Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 00 E-mail: gepcbel@gepc.ge.com

GE imagination at work
680867 Ref. I/3253/E/EX 5.0 Ed.02/09 Copyright GE Power Controls 2009