You are on page 1of 3

1900MHz Dual Mode Digital Wireless Repeater

RX-1939
Features
Support GSM and WCDMA HSPA simultaneously Total 4 pass band segments, for GSM or WCDMA with independent ON/OFF for maximum flexibility. 10W total output power. Utilise linear and high efficiency MCPA that support multi-protocol operation Integrated wireless modem for remote configuration, monitoring and control. Internal backup battery keeps the alarm unit running for up to two hours after power failure. Compatible to Comba generic OMT and OMC platform. Designed for all weather outdoor installation waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

DL LNA

DL CHANNEL 1 DL CHANNEL 2 DL CHANNEL 3 DL CHANNEL 4

DL PA

BTS

Donor Ant DT
UL PA

Digital Frequency Selective Module


UL CHANNEL 1 UL CHANNEL 2 UL CHANNEL 3 UL CHANNEL 4

Mobile Ant MT
Mobile
UL LNA

OMT Computer with Data card Modem

Alarm Indicator

Main Control Unit

Power Supply

Li- ion BATT

Wireless Modem

OMC

OMT

External Power

GSM 1 (0.8-25MHz) or WCDMA1 (1~3carriers) Adjustable

GSM 2 (0.8-25MHz) or WCDMA2 (1~3carriers) Adjustable

GSM3 (0.8-25MHz) or WCDMA3 (1~3carriers) Adjustable

GSM4 (0.8-25MHz) or WCDMA4 (1~3carriers) Adjustable

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued: 19Apr12 Control: 0-0-2 1/3

1900MHz Dual Mode Digital Wireless Repeater


RX-1939
Preliminary Technical Specifications Electrical
Operating Frequency, Uplink Operation Frequency, Downlink Operating Bandwidth Per Sub-band Carriers Per Sub-band Sub-bands Output Power, Uplink Total Output Power, Downlink System Gain Downlink System Gain Uplink Gain Adjustment Range (1dB step) Pass Band Ripple, p-p Uplink Noise Figure System Group Delay Out-of-Band Gain @ maximum bandwidth Intermodulation Spurious Emission EVM ACRR PCDE Spurious Emission Mask* 600kHz Out-of-Band Rejection Input VSWR Absolute Maximum RF Input Power, Downlink Impedance dBm 1MHz 5MHz dBc dBm dBm dB dB dB dB dB sec dB dBm dBm / dB dB / / FCC / / / / -50 -55 -65 1.5 +10 50 / Compliance with 3GPP TS 25 106 6 5 6.5 MHz MHz MHz / 4 30 1.5 40 1.5 90 2 90 2 0 30 2/3.84MHz GSM 1850 - 1910 1930 - 1990 0.8-25MHz adjustable / 1~3 adjustable WCDMA

Power, Mechanical & Environmental


Dimensions, H x W x D Weight (approx.) Power Supply Power Consumption (approx.) Power Up Waiting Time (approx.) MCU Battery Backup Time (approx.) Enclosure Cooling RF Connectors Operating Temperature Operating Humidity Environmental Class MTBF hr C mm 492 x 372 x 228 35 100-240 / 47-63Hz 300 60 2 Fan N-Female -33 to +55 95% IP65 50,000 Note: Typical specification at room temperature *: Uplink test at 23dBm output

kg
VAC W sec hr

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued: 19Apr12 Control: 0-0-2 2/3

1900MHz Dual Mode Digital Wireless Repeater


RX-1939
Operation and Maintenance
Using a direct connection to a PC by RJ45, installation and commissioning of the RX-1939 is accomplished by the OMT. Using the integrated wireless modem (data or SMS mode), the equipment parameters can be monitored and controlled remotely. Controlled equipment parameters include: Equipment ID, Phone Number, Sampling Time, Operating Band Switch, Channel No. Range, ATT, PA Switch, Over-Temp Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report Enable. Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Chassis Lock, DL Output Power Low, DL Input power Overload, Over Temp, DL VSWR, DL/UL ALC Trigger, Battery Low), DL Output Power and DL Input Power. The RX-1939 has been developed to take advantage of advanced network operation, where the OMC (optional) provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued: 19Apr12 Control: 0-0-2 3/3