Doulton Road, Cradley Heath, West Midlands, B64 5QB
Tel: +44 (0) 1384 567755 Fax: +44 (0) 1384 567710 Email: rail@sts-international.co.uk 11/10 2010 - STS Rail Ltd Page 1 of 2 TY160/GRP01-06 - BRB966 F6 AC IMMUNE DC NEUTRAL LINE RELAY Web: www.sts-rail.com SNNA S T S
R a i I
C a t a I o g u e
N u m b e r
S T S
R e f e r e n c e
( W e s t i n g h o u s e
R e f e r e n c e )
R a t e d
V o I t a g e
C o n t a c t s
P i n
C o d e
( P i n s )
S p e c i f i c a t i o n
TY160/GRP01 SNNA1 (QNNA1) 50 V DC 6F 2B x 2 209 (C, E, F ,H, J) BRB966 F6 TY160/GRP02 SNNA1 (QNNA1) 50 V DC 4F 4B x 2 210 (C, E, G, H, J) BRB966 F6 TY160/GRP03 SNNA1 (QNNA1) 50 V DC 2F 2B x 2 210 (C, E, G, H, J) BRB966 F6 TY160/GRP04 SNNA1 (N/A) 24 V DC 6F 2B x 2 962 (C, F, K ,L, M) (BRB966 F6) |
TY160/GRP05 SNNA1 (N/A) 24 V DC 4F 4B x 2 963 (C, G, H, J, M) (BRB966 F6) |
TY160/GRP06 SNNA1 (N/A) 24 V DC 2F 2B x 2 963 (C, G, H, J, M) (BRB966 F6) |
The twin relays covered by this data sheet are for use in line circuits where alternating current at industrial frequency may be present in the circuit. STS RaiI ReIays.
Modular plug in design. Non weld contacts. Silver and carbon impregnated with silver contact tips. Proven reliability. Low life cycle cost. (FORMERLY FELD AND GRANT) NOTE: | Specification in brackets where the relay is nominally to that specification but with specific characteristics modified to suit special applications. A B C D 1 F F F F 1 2 2 3 F F F F 3 4 4 5 B F F B 5 6 6 7 B F F B 7 8 8 R1 COIL 1
COIL 2 R2 R3 COIL 1
COIL 2 R4 6F 2B x 2 TY160/GRP01 & TY160/GRP04 REAR VEW OF RELAY 2010 - STS Rail Ltd Page 2 of 2 TY160/GRP01-06 - BRB966 F6 AC IMMUNE DC NEUTRAL LINE RELAY F = Front contact, which is made when the relay is energised. This is a normally open contact. B = Back contact, which is made when the relay is de-energised and the armature has completed its maximum travel. This is a normally closed contact. SNNA A B C D 1 F F F F 1 2 2 3 F F F F 3 4 4 5 B B B B 5 6 6 7 B B B B 7 8 8 R1 COIL 1
COIL 2 R2 R3 COIL 1
COIL 2 R4 4F 4B x 2 TY160/GRP02 & TY160/GRP05 REAR VEW OF RELAY A B C D 1 F F 1 2 2 3 F F 3 4 4 5 B B 5 6 6 7 B B 7 8 8 R1 COIL 1
COIL 2 R2 R3 COIL 1
COIL 2 R4 2F 2B x 2 TY160/GRP03 & TY160/GRP06 REAR VEW OF RELAY Contact Arrangements. S T S
R a i I
C a t a I o g u e
N u m b e r
C o i I
R e s i s t a n c e
P o w e r
C o n s u m p t i o n
F u I I
O p e r a t e
R e I e a s e
F u I I
R e I e a s e
C o n t a c t
R a t i n g
C o n t a c t
R e s i s t a n c e
W e i g h t
TY160/GRP01 TY160/GRP02 TY160/GRP03 935 C 2.7 W 40.0 V 7.5 V 4.0 V 3 A 0.2 C 1.3 kg TY160/GRP04 TY160/GRP05 TY160/GRP06 250 C 2.3 W 19.2 V 3.6 V 2.0 V 3 A 0.2 C 1.3 kg
P r e l i m i n a r y P r e l i m i n a r y
Australian Distributor
Relay Monitoring Systems Pty Ltd 6 Anzed Court Mulgrave, Victoria, 3170, Australia