You are on page 1of 3

STS Rail Ltd

Doulton Road, Cradley Heath, West Midlands, B64 5QB



Tel: +44 (0) 1384 567755
Fax: +44 (0) 1384 567710
Email: rail@sts-international.co.uk
11/10
2010 - STS Rail Ltd
Page 1 of 2
TY160/GRP01-06 - BRB966 F6
AC IMMUNE DC NEUTRAL LINE RELAY
Web: www.sts-rail.com
SNNA
S
T
S

R
a
i
I

C
a
t
a
I
o
g
u
e

N
u
m
b
e
r

S
T
S

R
e
f
e
r
e
n
c
e

(
W
e
s
t
i
n
g
h
o
u
s
e

R
e
f
e
r
e
n
c
e
)

R
a
t
e
d

V
o
I
t
a
g
e

C
o
n
t
a
c
t
s

P
i
n

C
o
d
e

(
P
i
n
s
)

S
p
e
c
i
f
i
c
a
t
i
o
n

TY160/GRP01 SNNA1
(QNNA1)
50 V DC 6F 2B x 2 209 (C, E, F ,H, J) BRB966 F6
TY160/GRP02 SNNA1
(QNNA1)
50 V DC 4F 4B x 2 210 (C, E, G, H, J) BRB966 F6
TY160/GRP03 SNNA1
(QNNA1)
50 V DC 2F 2B x 2 210 (C, E, G, H, J) BRB966 F6
TY160/GRP04 SNNA1
(N/A)
24 V DC 6F 2B x 2 962 (C, F, K ,L, M) (BRB966 F6)
|

TY160/GRP05 SNNA1
(N/A)
24 V DC 4F 4B x 2 963 (C, G, H, J, M) (BRB966 F6)
|

TY160/GRP06 SNNA1
(N/A)
24 V DC 2F 2B x 2 963 (C, G, H, J, M) (BRB966 F6)
|

N
e
t
w
o
r
k

R
a
i
I

A
c
c
e
p
t
a
n
c
e

N
u
m
b
e
r

PA05/3896
PA05/3896
PA05/3896
N/A
N/A
N/A
ReIay Description.

The twin relays covered by this data sheet are for use in line
circuits where alternating current at industrial frequency may be
present in the circuit.
STS RaiI ReIays.

Modular plug in design.
Non weld contacts.
Silver and carbon impregnated with silver contact tips.
Proven reliability.
Low life cycle cost.
(FORMERLY FELD AND GRANT)
NOTE:
|
Specification in brackets where the relay is nominally to that specification but with specific characteristics
modified to suit special applications.
A B C D
1
F F F F
1
2 2
3
F F F F
3
4 4
5
B F F B
5
6 6
7
B F F B
7
8 8
R1
COIL
1

COIL
2
R2
R3
COIL
1

COIL
2
R4
6F 2B x 2
TY160/GRP01 & TY160/GRP04
REAR VEW OF RELAY
2010 - STS Rail Ltd
Page 2 of 2
TY160/GRP01-06 - BRB966 F6
AC IMMUNE DC NEUTRAL LINE RELAY
F = Front contact, which is
made when the relay is energised.
This is a normally open
contact.
B = Back contact, which is
made when the relay is
de-energised and the armature
has completed its maximum travel.
This is a normally closed contact.
SNNA
A B C D
1
F F F F
1
2 2
3
F F F F
3
4 4
5
B B B B
5
6 6
7
B B B B
7
8 8
R1
COIL
1

COIL
2
R2
R3
COIL
1

COIL
2
R4
4F 4B x 2
TY160/GRP02 & TY160/GRP05
REAR VEW OF RELAY
A B C D
1
F F
1
2 2
3
F F
3
4 4
5
B B
5
6 6
7
B B
7
8 8
R1
COIL
1

COIL
2
R2
R3
COIL
1

COIL
2
R4
2F 2B x 2
TY160/GRP03 & TY160/GRP06
REAR VEW OF RELAY
Contact Arrangements.
S
T
S

R
a
i
I

C
a
t
a
I
o
g
u
e

N
u
m
b
e
r

C
o
i
I

R
e
s
i
s
t
a
n
c
e

P
o
w
e
r

C
o
n
s
u
m
p
t
i
o
n

F
u
I
I

O
p
e
r
a
t
e

R
e
I
e
a
s
e

F
u
I
I

R
e
I
e
a
s
e

C
o
n
t
a
c
t

R
a
t
i
n
g

C
o
n
t
a
c
t

R
e
s
i
s
t
a
n
c
e

W
e
i
g
h
t

TY160/GRP01
TY160/GRP02
TY160/GRP03
935 C 2.7 W 40.0 V 7.5 V 4.0 V 3 A 0.2 C 1.3 kg
TY160/GRP04
TY160/GRP05
TY160/GRP06
250 C 2.3 W 19.2 V 3.6 V 2.0 V 3 A 0.2 C 1.3 kg


P
r
e
l
i
m
i
n
a
r
y
P
r
e
l
i
m
i
n
a
r
y































Australian Distributor



Relay Monitoring Systems Pty Ltd
6 Anzed Court
Mulgrave, Victoria, 3170, Australia

Phone: +61 3 8544 1200
Fax: +61 3 8544 1201
Email: rms@rmspl.com.au
Web: www.rmspl.com.au