This training report is a part of course curriculum of B.Tech degree program. This training is made essential part of us so as to familiarize ourselves to the environment of the industry. This training report is based on the training done at BSNL, Gorakhpur. The report consists of the general study of the various devices and component. I feel proud to present the training report before General Manager (G.M.) of BSNL, Gorakhpur.
ABOUT BSNL
On October 1, 2000 the Department of Telecom Operations, Government of India became a corporation and was christened Bharat Sanchar Nigam Limited (BSNL). Today, BSNL is the largest Public Sector Undertaking of India and its responsibilities include improvement of the already impeccable quality of telecom services, expansion of telecom network introduction of new telecom services in all villages and instilling confidence among its customers. At present the BSNL is the World's Largest Seventh and India's First Telecommunication Company. Responsibilities that BSNL has managed to shoulder remarkably, definitely. BSNL is the largest telecom operator in India and is known to everybody for Basic Telephony Services for over 100 years. Presently the plain old, countrywide telephone service is being provided through 32,000 electronic exchanges, 326 Digital Trunk Automatic Exchanges(TAX), Digitalized Public Switched Telephone Network (PSTN) all interlinked by over 2.4 lakhs km of Optical Fiber Cable, with a host of Phone Plus value additions to our valued Customers. BSNL's telephony network expands throughout the vast expanses of the country reaching to the remotest part of the country. Driven by the very best of telecom technology from chosen global leaders, it connects each inch of the nation to the infinite corners of the globe, to enable you to step into tomorrow. Along with its vast customer base, BSNL's financial and asset bases too are vast and strong. The telephone infrastructure along is worth about Rs. 1, 00,000 crore (US $ 21.2 billion). Turnover of Rs. 22,000 crore (US $ 4.6 billion). Now from latest news BSNL records a net profit of Rs. 6,312 crore on revenues of Rs.24, 300 crore for the financial year 2001-02. BSNL is working round the clock to take India into the future by providing world class telecom services for the people of India.
HISTORY:
The use of visible optical carrier waves or light for communication has been common for many years. Simple systems such as signal fires, reflecting mirrors and, more recently signaling lamps have provided successful, if limited, information transfer. Moreover as early as 1880 Alexander Graham Bell reported the transmission of speech using a light beam. The photo phone proposed by Bell just for years after the invention of the telephone modulated sunlight with a diaphragm giving speech transmission over a distance of 200m. However, although some investigation of the optical communication continued in the early part of the 20th century its use was limited to mobile, low capacity communication links. This was due to both the lack of suitable light sources and the problem that light transmission in the atmosphere is restricted to line of sight and severely affected by disturbances such as rain, snow, fog dust and atmospheric turbulence. A renewed interest in optical communication was stimulated in the early 1960s with the invention of the laser. This device provided a coherent light source, together with the possibility of the modulation at high frequency. The proposals for optical communication via optical fibers fabricated from glass to avoid degradation of the optical signal by the atmosphere were made almost simultaneously in 966 by Kao and Hock ham and Wert. Such systems were viewed as a replacement for coaxial cable system; initially the optical fibers exhibited very high attenuation and were therefore not comparable with the coaxial cable they were to replace. There were also problems involved in jointing the fiber cables in a satisfactory manner to achieve low loss and to enable the process to be performed relatively easily and repeatedly in the field. In coaxial system the channel capacity is 300 to 10800 and the disadvantages of the coaxial system are digging, electrical disturbance, in winter cable contracts and breaks mutual induction. The coaxial cable loss is 0.3db per every km.
3
In microwave system if we double the distance the loss will be increased by 6db. For the shorter distance the loss is higher. In OFC system Optical wire is small size, light weight, high strength and flexibility. Its transmission benefits include wide band width, low loss and low cost. They are suitable for both analog and digital transmission. It is not suffered by digging, electrical interference etc. problems.
For optical fiber communication system shown in fig b. information source provides an electrical signal to a transmitter comprising an electrical stage which drives an optical source to give modulation of the light wave carrier. The optical source which provides the electrical, optical conversion may be either a semiconductor laser or light emitting diode (LED). The transmission medium consist of an optical fiber and the receiver consist of an optical detector which drives a further electrical stage hence provide demodulation of optical carrier. Photodiodes and in some instances, photransistor and photoconductors are utilized for the detection of the optical signal and the optical electrical conversion. The optical carrier may be modulated either an analog or digital information signal. In the system shown in fig b. analog modulation involves the variation of the light emitted from the optical source in a continuous manner. With digital modulation, however, discrete changes in the light intensity are obtained (on/off pulses). Although often simpler to implement, analog modulation with an optical fiber communication system is less efficient, requiring a far higher s/n ratio at than digital modulation. Also, the linearity needed for analog modulation is not always provided by semiconductor optical sources, especially at high modulation frequencies. For this reasons, analog optical fiber communication links are generally limited to shorter distances and lower bandwidths than digital links.
At the receiving end of fiber, a light detector senses the light. Thus, the communication medium is the fiber, and the energy used is light energy. The typical fiber communication system.
FEATURES:
The fiber optics has become a preferred medium due to its some important features like: The bandwidth of the fiber and light beam is extremely wide. It is possible to handle signals which turn on and off at gigabit per second rates (1 gigabit, gbit =1000 Mbitts). The fiber itself is very thin and not expensive. The thinness means that it is easy to handle, and many fibers can be put in the trenches or narrow conduits. The light signal is absolutely immune to electrical noise from any sources. Even if there are sources of electrical noise directly touching the cable, the electric fields of the noise source cannot affect the light beam in the fiber. The signal in the cable is secure from unauthorized listeners. It is relatively hard to tap into the cable without being noticed, and the entire light signal is confined within the fiber. No light escapes to the outside where someone else could see it. Since there is no electricity or electrical energy in the fiber, it can be run in hazardous atmospheres where the danger of explosion from spark may exist. Also, the fiber itself is immune to many types of poisonous gases, chemicals, and water.
ESSENTIAL FEATURES OF AN OPTICAL FIBER: 1) Optical fibers may be produced with good stable transmission characteristics in long
lengths at a minimum cost and with maximum reproducibility. 2) A range of optical fiber types with regard to size, refractive indices and index profiles, operating wavelengths, materials etc. be available in order to fulfill many different system applications. 3) The fibers may be converted into practical cables which can be handled in a similar manner to conventional electrical transmission cables without problems associated with the degradation of their characteristics or damage.
4) The fibers and fiber cables may be terminated and connected together without
excessive [practical difficulties and in ways which limit the effect of this process on the fiber transmission characteristics to keep them within acceptable operating levels. It is important that these jointing techniques may be applied with ease in the field location where cable connection takes place.
7
JOINT OF FIBER:
Optical fiber links, in common with any line communication system, have requirement for both jointing and termination of the transmission medium. The number of intermediate fiber connections or joints is dependent upon the link length, the continuous length of the fiber cable that may be produced by the preparation methods and the length of the fiber cable that may be practically installed as a continuous section on the link. It is therefore apparent that fiber to fiber connection with low loss and minimum distortion (i.e. modal noise) remains an important aspect of optical fiber communication system. Before optical fibers splicing and joining are done certain preparations are made with fiber or fiber cables as case may be to achieve best results at the end surface. First of all the protective plastic that covers the glass cladding is stripped from each fiber end, which is then cleaved with a special tool, producing a smooth and flat end. 1) Fiber splices: these are semi permanent or permanent joints which find major use in most optical fiber telecommunication system (analogous to electrical soldered joints). 2) Demountable fiber connectors or simple connectors: these are removable joints which allow easy, fast, manual coupling and uncoupling of fibers (analogous to electrical plugs and sockets). The above fiber to fiber joints are designed ideally to couple all the light propagating in one fiber into the adjoining fiber. By contrast fiber couplers are branching devices that split all the light from main fiber into two or more fibers or, alternatively, couple a proportion of the light propagating in the main fiber into main fiber.
FIBER SPLICES:
A permanent joint formed between two individual optical fibers in the field or factory is known as a fiber splice. Fiber splicing is frequently used to establish long haul optical fiber links where smaller fiber lengths need to be joined, and there is no requirement for repeated connection and disconnection. Splices may be divided into two
broad categories depending upon the splicing technique utilized. These are fusion splicing or welding and mechanical splicing. Fusion splicing is accomplished by applying localized heating(e.g. by a flame or an electric are ) at the interface between two butted, prealigned fiber ends causing them to soften and fuse. Mechanical splicing, in which the fibers are held in alignment by some mechanical means, may be achieved by various methods including the use of tubes around the fiber ends (groove splices). A requirement with fibers intended for splicing is that they have smooth and square end faces. In general this end preparation may be achieved using a suitable tool which cleaves the fiber as illustrated.
FUSION SPLICES:
The fusion splicing of single fibers involves the heating of the two prepared fiber ends to their fusing point with the application of sufficient axial pressure between the two optical fibers. It is therefore essential that the stripped (of cabling and buffer coating) fiber ends are adequately positioned and aligned in order to achieve good continuity of the transmission medium at the junction point. Hence the fiber are usually positioned and clamped with the aid of an inspection microscope. Flame heating sources such as micro plasma torches (argon and hydrogen) and oxhydric micro burners (oxygen, hydrogen and alcohol vapour) have been utilized with some success. However, the most widely used heating source is an electric arc. This technique offers advantages of consistent, easily controlled heat with adaptability for use under field conditions. A schematic diagram of the basic two fibers is welded together. Shows a development of the basic are fusion process which involves the rounding of the fiber ends with a low energy discharge before pressing the fibers together and fusing with a stronger arc. This technique, known as perfusion, removes the requirement for fiber end preparation which has a distinct advantage in the field environment. A possible drawback with fusion splicing is that the heat necessary to fuse the fibers may weaken the fiber in the vicinity of the splice. It has been found that even with careful handling; the tensile strength of the fused fiber may be as low as 30 % of that of the uncoated fiber before fusion.
10
2) Fiber cutter. y It converts irregular shaped fiber end into smooth & flat end.
3) Chemicals used in OFC joint. y y y HAXENE : To remove jelly from the fiber ACETONE : For cleaning the OFC ISO PROPENOT: For smoothness of optical glass.
4) Sleeve: - To enclose fiber joint. 5) Tool Kit 6) Joint kit. y y y Joint enclose Buffer Adhesive tape.
11
A block schematic of the backscatter measurement method. A light pulse is launched into the fiber in the forward direction from an injection laser using either a directional coupler or a system of external lenses with a beam splitter (usually only in the laboratory). The backscattered light is detected using an avalanche photodiode receiver which drives an integrator in order to improve the received signal to noise ratio by giving an arithmetic average over a number of measurements taken at one point within the fiber. This provides location dependent attenuation values which give an overall picture of the optical loss down the link.
Although the usable fiber bandwidth will be extended further towards the optical carrier frequency, it is clear that this parameter is limited by the use of a signal optical carrier signal. Hence much enhanced bandwidth utilization for an optical fiber can be achieved by transmitting several optical signals, each at different centre wavelengths, in parallel on the same fiber. This wavelength division multiplexed operation, particularly with dense packing of the optical wavelengths (or, essentially, fine frequency spacing), offers the potential for a fiber information carrying capacity which is many orders of magnitude in excess of that obtained using copper cables or a wideband radio system. y Small Size and Weight: - Optical fibers have very small diameters which are often no greater than the diameter of a human hair. Hence, even when such fibers are covered with protective coatings they are far smaller and much lighter than corresponding copper cables. This is a tremendous boon towards the alleviation of duct congestion in cities, as well as allowing for an expansion of signal transmission within mobiles such as aircraft, satellites and even ships. y Electrical Isolation: - Optical fibers which are fabricated from glass, or sometimes a plastic polymer, are electrical insulators and therefore, unlike their metallic counterparts, they do not exhibit earth loop and interface problems. Furthermore, this property makes optical fiber transmission ideally suited for communication in electrically hazardous environments as the fibers create no arching or spark hazard at abrasions or short circuits. y Immunity To Interference And Crosstalk: - Optical fibers form a dielectric waveguide and are therefore free from electromagnetic interference (EMI), radiofrequency interference (RFI), or switching transients giving electromagnetic pulses (EMP). Hence the operation of an optical fiber communication system is unaffected by transmission through an electrically noisy environment and the fiber cable requires no shielding from EMI. The fiber cable is also not susceptible to lightning strikes if used overhead rather than underground. Moreover, it is fairly easy to ensure that there is no optical interference between fibers and hence, unlike communication using electrical conductors, crosstalk is negligible, even when many fibers are cabled together. y Signal Security: - The light from optical fibers does not radiate significantly and therefore they provide a high degree of signal security. Unlike the situation with copper cables, a transmitted optical signal cannot be obtained from a fiber in a noninvasive
13
manner (i.e. without drawing optical power from the fiber). Therefore, in theory, any attempt to acquire a message signal transmitted optically may be detected. This feature is obviously attractive for military, banking and general data transmission (i.e. computer network) application. y Low Transmission Loss: - The development of optical fibers over the last twenty years has resulted in the production of optical fiber cables which exhibit very low attenuation or transmission loss in comparison with the best copper conductors. Fibers have been fabricated with losses as low as 0.2 dB km-1 (see Section 3.3.2) and this feature has become a major advantage of optical fiber communications. It facilitates the implementation of communication links with extremely wide repeater spacing ( long transmission distances without intermediate electronics), thus reducing both system cost and complexity. Together with the already proven modulation bandwidth capability of fiber cable this property provides a totally compelling case for the adoption of optical fiber communication in the majority of long-haul telecommunication applications. y Ruggedness and Flexibility: - Although protective coatings are essential, optical fibers may be manufactured with very high tensile strengths. Perhaps surprisingly for a glassy substance, the fibers may also be bent to quite small radii or twisted without damage. Furthermore cable structures have been developed which have proved flexible, compact and extremely rugged. Taking the size and weight advantage into account, these optical fiber cables are generally superior in terms of storage, transportation, handling and installation to corresponding copper cables, whilst exhibiting at least comparable strength and durability. y System Reliability and Ease Of Maintenance: - These features primarily stem from the low loss property of optical fiber cables which reduces the requirement for intermediate repeaters or line amplifiers to boost the transmitted signal strength. Hence with fewer repeaters, system furthermore, the reliability of the optical components is no longer a problem with predicted lifetimes of 20 to 30 years now quite common. Both these factors also tend to reduce maintenance time and costs. y Potential Low Cost: - The glass which generally provides the optical fiber transmission medium is made from sand not a scarce resource. So, in comparison with copper conductors, optical fibers offer the potential for low cost line communication. Although
14
over recent years this potential has largely been realized in the costs of the optical fiber transmission medium which for bulk purchases is now becoming competitive with copper wires (i.e. twisted pairs), it has not yet been achieved in all the other component areas associated with optical fiber communication. For example, the costs of high performance semiconductor lasers and detector photodiodes are still relatively high, as well as some of those concerned with the connection technology (demountable connectors, couplers, etc.).
JUNCTION NETWORK: The junction or interoffice network usually consists of routes within major conurbations over distances of typically 5 to 20 km. However, the distribution of distances between switching centers (telephone exchanges ) or offices in the junction network of large urban areas varies considerably for various countries. MILITARY APPLICATION: In these applications, although economics are important, there are usually other, possibly overriding, considerations such as size, weight, deployability, survivability (in both conventional and nuclear attack and security. The special attributes of optical fiber communication system therefore often lend themselves to military use. y MOBILES: One of the most promising areas of milita5ry application for optical fiber communication is within military mobiles such as aircraft, ships and tanks. The small size and weight of optical fibers provide and attractive solution to space problems in these mobiles which are increasingly equipped with sophisticated electronics. Also the wideband nature of optical fiber transmission will allow the multiplexing of a number of signals on to a common bus. Furthermore, the immunity of optical transmission to electromagnetic interference (EMI) in the often noisy environment of military mobiles is a tremendous advantage. This also applies to the immunity of optical fiber to lighting and electromagnetic pulses (EMP) especially within avionics. The electrical isolation, and therefore safety, aspect of optical fiber communication also proves invaluable in these applications, allowing routing through both fuel tanks and magazines. y COMMUNICATION LINKS: The other major area for the application of optical fiber communication in the military sphere includes both short and long distance communication links. Short distance optical fiber systems may be utilized to connect closely spaced items of electronics equipment in such areas as operations rooms and computer installations. A large number of this system has already been installed in military installations in the United Kingdom. These operate over distances from several centimeters to a few hundred meters at transmission rates between 50 bauds and 4.8 kbits-1. In addition a small number of 7 MHz video links operating over distances of up to 10 m are in operation. There is also a
16
requirement for long distance communication between military installations which could benefit from the use of optical fibers. In both these advantages may be gained in terms of bandwidth, security and immunity to electrical interference and earth loop problems over conventional copper systems. y CIVIL APPLICATION: The introduction of optical fiber communication systems into the public network has stimulated investigation and application of these transmission techniques by public utility organizations which provide their own communication facilities over moderately long distances. For example these transmission techniques may be utilized on the railways and along pipe and electrical power lines. In these applications, although high capacity transmission is not usually required, optical fibers may provide a relatively low cost solution, also giving enhanced protection in harsh environment, especially in relation to EMI and EMP. Experimental optical fiber communication systems have been investigated within a number of organizations in Europe, North America and Japan. For instance, British Rail has successfully demonstrated a 2 Mbits-1 system suspended between the electrical power line gantries over a 6 km route in Cheshire. Also, the major electric power companies have shown a great deal of interest with regard to the incorporation of optical fibers within the metallic earth of overhead electric power lines.
TELEPHONE EXCHANGE:
INTRODUCTION: The main function of an exchange is to process call from a calling subscriber and make the connection to the called subscriber. This connection can be direct or via another exchange. This requires all parts of the exchange to work as a unit to ensure the call is properly handled. CALL PROCESSING ARCHITECTURE: The main function of the exchange is to process subscriber calls. The exchange does this by connecting an incoming line or trunk to another line or trunk. However call processing involves much more than simply connecting subscribers. In order to process the calls the exchange must perform four basic switching functions.
17
y y
Supervision: Detects and reports service requests, acknowledgements and requests to terminate service.
y y
Signaling: Transmits information about lines and trunks and information about other aspects of call handling to control switching equipment.
y y
Routing: Converts address information to the location of the corresponding call line or to the location of a trunk on the way to that line.
y y
BASIC CALL TYPES: Subscriber calls are grouped in to categories that distinguish one call from another. These categories are referred to as call types. The basic call types are:y Intra exchange calls: - these are calls between two subscribers served by the same exchange. These calls are normally line to line calls. y Inter exchange calls: - these are calls that involve two or more exchanges. Within a given exchange there are different types of inter exchange calls. An outgoing call is a call that goes out of the exchange via a trunk. If the call originated in the same exchange, it is called an originating outgoing call. An incoming call is a call that comes into the exchange via a trunk. A tandem call is a call that comes into the exchange on one trunk and leaves the exchange on another trunk. Thus a tandem call is both incoming and outgoing.
18
CALL PROCESSING STAGES:An intra exchange call which is the simplest of the call types mentioned above, progresses through four basic stages:
y y y y
Idle Digit reception and analysis Ringing talking Inter exchange calls are more complex, and their call processing stages are somewhat different.
19
SERVICE CATEGORY: y
Residence and business subscriber services: - Example of this category are individual, 2-party and multiparty lines, abbreviated dialing, call waiting, 3-way calling all diversion, call barring and multi line hunting. y Extended business services: - Examples of these services are PBX, indirect inward dialing and toll diversion. y Public safety services: - Examples of this category are basic emergency service, out going call trace, and in-progress call trace and in progress call trace. y Miscellaneous local system services: - it like loop-range services, integrated and universal pair gain interface and line signaling. y y Inter exchange services: - Various inter exchange signaling types. Call processing services: - Generalized screening, digit interpretation timing, routing and remote switching modules. y Toll services: - Toll exchange trunks, auxiliary service trunks, and operator trunks. Of termination: trunk and line. The trunk termination involves selecting an
20
idle member in the trunk group and out pulsing the received digits. For a trunk, the particular selected trunk group, the no. of members in the trunk group and the digits to be out pulsed and the way the trunk group is selected, are of utmost importance. y The line termination involves checking to find whether the line is busy and applying rin2ging to the line.
21
MDF (Main Distribution frame) The Subscriber's lines enter an exchange through a number of large capacity U/G cables, each of which serves a different part of the exchange area. The numbers given to the subscriber's lines do not bear any relationship to the geographical location of the subscriber. Hence, the exchange numbers included in any one cable are entirely haphazard. Moreover, as subscribers cease to have telephones and new subscribers are connected, the exchange numbering of the external cable pairs is constantly changing. On the other hand, all lines within the exchange are in strict numerical order. It is, therefore, necessary that some means must be provided for temporary connection between the two. This conversion from the geographical order of the external pairs to the numerical order within the exchange is carried out on a main distribution frame. MDF is separately explained in another section. Exchange Card is a basic functional unit of the exchange. Various cards are utilized for various purposes e.g. Subscriber cards are utilized for termination of subscriber's cables coming from MDF. PCM Various subscriber's cables coming out from the subscriber's cards (After processing) are terminated into the DDF (Digital Distribution Frame) located inside PCM in between these two PCM tag block is there, which provide connectivity between these two. Various DDF's cables combine together and terminated into the OFC module (which is combination of electrical to light converter (Multiplexer and Demultiplexer). PCM is separately explained in another section.
MAIN DISTRIBUTION FRAME (M.D.F.):The subscribers line enter an exchange through a number of large capacity cables, each of which serves a different part of the exchange area. The numbers given to the subscribers lines do not bear any relationship to the geographical location of the subscriber. Hence the exchange numbers include in any one cable are entirely haphazard. Moreover, as subscribers cease to have telephones and new subscribers are connected, the exchange numbering of the external cable pairs is constantly changing. On the other hand, all lines within the exchange are in strict numerical order. It is, therefore, necessary that some means must be provided for temporary connection between the two. This conversion from the geographical order of the external pairs to the numerical order within the exchange is carried out on a main distribution frame.
FACILITIES PROVIDED BY M.D.F.:The M.D.F. provides for the following requirements: y y y A means for permanently terminating the external cables. For mounting the protective devices connected to the incoming circuits. Providing the connection between the exchange side and the line side by the jumpers. y An interception point for use in connection with fault locating tests.
Main distribution frame is mainly divided in two parts. (1) Vertical Side or Line side (2) LEN side or Exchange side
23
VERTICAL SIDE:-
y y y y y
All the part from vertical side to the subscriber are generally called outdoor section. 1 vertical has 10 tag block. Each tag block has 10 rows and each row has 10 tags. So each tag block has 100 tags. Connection between vertical side & subscribers are provided by jelly filled cables. This wires are first terminated in cabinet box, then according to requirements the group of the wires (e.g. 200 wires, 100 wires etc.) are terminated in pillar box & from here connections are given to the subscribers via DP box. LEN SIDE:-
24
y y y
All the parts from LEN to the exchange is called indoor section. The connection of subscriber from exchange is terminated on this side of MDF. In 1 tag block there are 128 tags. Each tag block is divided in 4 segments. That is 0, 1, 2 & 3 and in each segments. There are sixteen tags.
On the vertical side there is 100 tag in one vertical tag block where as on the LEN side there is 128 tags on each LEN block. The reason for this difference is that there is always a reserve of spare capacity in the external cables to cover fluctuations in the distribution of the subscribers lines as between the different localities served by the cables.
DIFFERENT TYPES OF FAULTS:The faults are given below which are established in communication of subscriber with exchange. LOOP FAULT:If two wires are joined together because of improper connection, storming air etc. then this type of fault occurs. EARTH FAULT:If two wires get scrape at some places and if this wire comes in contact with tree, pillar or any metal objects then this type of fault occurs. CABLE FAULT:For outdoor connections, jelly filled wires are used which are affected by natural causes such as rain, earthquake etc. At such time this fault occurs. DISCONNECT FAULT:This type of fault occurs due to the breaking of wires between the vertical side & LEN side. LOCATION OF FAULTS:This can be determined by putting pack up. If pack up is put in one of the tag of LEN side and if dial tone is received only upto the LEN side then fault is in the outdoor side and if tone is received from the subscriber only upto the vertical side then fault is in the indoor side. This fault are also identify by either subscriber line tester or by using the computerized programmed.
25
PROTECTIVE DEVICE USED ON M.D.F. Fuses These are the devices used to protect apparatus and wiring from excessive currents. A fuse is a small length of thin wire which melts if there is an excess of current and disconnect the equipment before possible damage. The rated current of fuse is the maximum current which it can carry without melting or fusing. The types of fuses used for connecting line to equipment are: (1) Glass type (2) Gate type GAS DISCHARGE TUBE (GD TUBE):In case of heavy lighting discharges or induction of high voltages, gas discharge protectors are used as protective device to protect the communication lines and equipments from damages due to high voltages. The gas discharge protector essentially consists of two of three tungsten electrodes sealed in a special glass envelope or ceramic envelope containing a mixture of inert gases , mainly neon. In case of three pin G.D. tube, two of the electrodes are for connections to the lines and third is the earth electrode and in case of two pin device, one electrode is connected to a limb of a line and other electrode is connected to earth. If the potential difference across the electrodes rises to a certain critical value, the gas is ionized and becomes conducting. This condition will continue till the potential difference across the electrodes falls to the extinction voltage value. For voltages less than striking value, it will not conduct. For normal operating voltage on the lines, it offers extremely high impedance and thus does not introduce any transmission loss. APPLICATIONS:y y y MDF mainly provide connection between outdoor and indoor. MDF is basically the protection system for exchange. It uses Fuse as a protection device which prevents to reach the high current from outside to exchange.
y It uses Gas Discharge Tube (GD Tube) which provide protection against high excessive
voltage.
26
C-DOT EXCHANGE:
INTRODUCTION Center development of telemetric was formed in year 1985 by an act of parliament under ministry of telecommunication with prime objective to develop indigenous state of art electronics switch suitable for Indian network condition. Various products proposed to be developed by C-DOT include small RAX exchange of 128 ports for rural network to big C-DOT MAX-XL exchange for metropolitan applications. C-DOT DSS MAX is a universal switch and can be used as local, transmit or integrated local and transmit switch. It can have minimum capacity of 512 ports. And can grow up to 16000 ports without concentration. It has digital switching based on basic 64kpbs basic rate and 2mbps primary rate multiplexing structure. The development of C-DOT DSS MAX has taken place in family concept. It is fully integrated switch starting from smaller switches, bigger switches and can be built in a modular fashion by configuring hardware and software modules in variety of ways. The C-DOT DSS system can be used in telecommunication network at the various switching nodes for different type of services. Some of them are C-DOT DSS as MAX:This can be used as main automatic exchange which is expandable to large capacity of order of 2000 lines or beyond. The MAX may be here remote module (RM) and remote line concentrators (RLC) connected to it. C-DOT DSS as RAX:This can be used as rural automatic exchange and is expandable up to 2000 lines capacity. Single base module configuration comes under the RAX category. Thus it is universal switch which can be configured as local, transit and integrated local and transit switch. It provides both local and centralized operation and maintenance. SYSTEM ARCHITECTURE:It can serve metropolitan, urban, rural environments. Its architecture is such that it is possible to upgrade a working C-DOT SBM( single base module) or MBM ( multi base module) exchange to provide ISDN service through RSU ( remote switching unit). RSU can provide switching facility locally even in case of failure of communication path to parent exchange. In uses TST (time space switching).
27
C-DOT DSS MAX exchange can be configured from the following basic modules: 1. Base Module (BM) 2. Central Module (CM) 3. Administrative Module (AM) 4. Input Output Processor (IOP) 5. Alarm Display Panel (ADP)
BASE MODULE (BM):Depending upon the capacity of the exchange either single BM or more BMs are used. In case of 512 ports, only one BM is used. However under low traffic condition, the capacity of the ports can be increased up to 2048 ports by using two line modules and adopting concentration mode. In multi module working of BMs will range from 2 to 32.
Frames of BM:One BM consists of 6frames inside it. The top four frames are called terminal units (TU). TU houses various types of cards in them e.g. Power Supply Card (PSU), Subscriber Line Card (SLC), Trunk Cards (TWT), Announcement Card (ANNC), Conference Card (CONF), Terminal Test Controller Card (TTC).The fifth frame of BM is called Base Processor Unit (BPU) which is the heart of the system. It consists controller and memory cards. The sixth frame of the BM is called Time Switch Unit (TSU). Power Supply:To energize various cards in the BM, different DC Voltages are required. They are 48V, +5V, +12V, -12V and 9V.for this purpose two types of power supply cards is employed. a) PSU-1: It caters various supplies to the four terminal units of the BM. In each TU, two PSU-1cards are there which work in load sharing mode i.e. in case of PSU-1card goes faulty, and the other is capable of taking the full load of the terminal unit. b) PSU-2: Two cards are used each in BPU and TSU. PSU-1differs from PSU-2 in one respect i.e. PSU-1besides supplying various D.C. supplies, generates 75V AC ringing current.
28
CENTRAL MODULE (CM):When in the system the number of BMs exceeds one ,the CM is used. The purpose of CM is to provide setting up of calls between a subscriber of one BM and a subscriber of the other BM. For this purpose one CM is sufficient up to 32 BMs.
ADMINISTRATIVE MOFULE (AM):Like CM, AM also used when the number of BMs in the system exceeds one. The AM is housed along with CM in one cabinet called CM.AM performs administrative and maintenance function.
INPUT OUTPUT PROCESSOR (IOP):The IOP performs following function: 1) Serves as a media for man machine communication. 2) Keeps the data concerning system. 3) Does system initialization. IOP is connected to the following peripheral units for the purpose noted against each, Visual Display Unit: This is used for giving command to establish communication with the system. VDU gives the display of the reports as a result of the command execution. Printer: For the printed reports.
ALARM DISPLAY UNIT (ADP):This is basically used for displaying the alarms raised in the system. The alarm gives both audio and visual indication. However, the audio alarm can be stopped by pressing acknowledge button on the ADP. The alarms raised are of three types, Critical: indicated by red LED. Urgent: indicated by orange LED. Non-urgent: indicated by green LED.
29
SYSTEM FEATURES:y y The C-DOT is a fully digital system with stored program control. In non-concentration mode of working, the switch is non-blocking i.e. calling party gets the called party if it is free. y y y System environment Relative Humidity = 45% to 65% The application of C-DOT can be either new exchange or a replacement of the existing exchange. y y The C-DOT can be used as a local or transmit exchange. The system has a modular growth i.e. for expanding the capacity of the exchange additional modules is to be installed. y The system provides for detailed billing in case of STD and ISD calls. However billing for local calls can also be arranged.
y The C-DOT employs distributed control system. SUBSCRIBER FEATURES:y y The subscriber can make local, national and international calls. The system provides for automatic selection of a free line from a group of lines serving a subscriber i.e. PBX hunting. y The system enables the subscriber to make a call to a fixed destination just by lifting his hand set. y When a subscriber is busy, there is a possibility of losing incoming calls. With the queue service system such call are not lost and on the contrary these calls are placed in the queue with appropriate announcement to the caller. y y y The subscriber can lock his outgoing calls. The subscriber can divert his calls. The trunk offer service enables the operator to interrupt a call in progress so that another incoming call could be offered to the concerned subscriber if he agrees to accept the call.
A subscriber can make local, national and international calls. These calls can be made using push button telephone sets employing dual-tone multi-frequency ( DTMF ) signals or dial pulses. PBX facilities: Facilities available on PBX lines include Direct inward dialing (DID) : Calls can be dialed from a telephone line connected to the public network directly to extensions of a PBX using the CDOT exchange Line hunting: The CDOT exchage provides for automatic selection of a free line from a group of line serving a subscriber on receipt of a call to that subscribers general directory number. RAPID CALL SET-SERVICES:Hot line The system provides the possibility for a subscriber to make a call to a fixed destination by just lifting his handset.
CALL BOOKING SERVICES:Alarm call The possibility for a subscriber to cause an alarm call or calls to be made to his line at a time or times specified in advance by him and to hear APPROPRIATRE announcement when the call answered. The alarm call service may be offered on a manual, semi-automatic or automatic basis.
CALL RESTRICTION SERVICE:A subscriber can have his incoming/outgoing calls barred. These includes denying all calls to a line, While allowing it to originate call denying various category of originations from a line while allowing incoming calls to terminate normally on it.
31
CALL COMPLETION SERVICES:AUTOMATIC CALL BACK It provides the the subscriber to be rung and get connected to the wanted subscriber if an earlier attempt was not successful on account of called subscriber being busy. Automatic call back is possible for An intra exchange call and An inter exchange call DIVERSION ON BUSY It provides the po0ssibility for a subscriber, who cannot receive a call because he is busy, to have the call diverted to another subscribers number. CALL WAITING A subscriber engaged on an existing call is given an indication that a caller is that a caller is attempting to obtain connection to his number. When the warning tone is fed to the engaged subscriber, he must respond either by flashing the hook switch or by terminating the call within t seconds. Otherwise the calling party is fed busy tone. PRIORITY LINES It provides the possibility of having some line in the exchange which get preference in being served in case abnormal condition like, overload or route congestion developed in the exchange. TRUNK OFFER It makes it possible for the operator to interrupt a call in progress, in order to allow another incoming call to be offered. CALL CHARGE SERVICES These facilities can be grouped into two charging information services charging debiting services charging information services Subscribers home meter or check meter Printed record on duration Coin collection boxes non metered lines
32
DIGITAL SWICHING:In Digital switching system signals are switched in digital form. These signals can be speech or data. For this Time Division multiplexing and pulse code modulation (PCM) techniques are used. Time Division multiplexer involves sharing of same transmission medium by a number of circuits or channels during a sequence of time periods. Thus the medium is periodically available to each channel.
The principle of T.D.M is illustrated in fig.1. The channels are connected to individual gates which are opened one by one in fixed sequence. At the receiving end also. Similar gates are opened in unison with the transmitting g end. Before transmitting these samples of individual channel signals are coded in binary form and pulses corresponding to the digits are transmitted. This is called pulse code modulation. These pulses are decoded at receiving end and combines to reproduce the original signal. In Digital switching the digital signals of several speech signals are multiplexed on common media. Therefore same path is shared by different calls for fraction of time. This process is repeated periodically at a suitably high rate. This type of path is called PCM highway. To connect any two subscribers, it is necessary to interconnect the time slots of the two speech samples which may be same or different PCM highway. For e.g. PCM samples appearing in TS3 of incoming PCM Highway 1 are transferred to TS6 0f outgoing PCM Highway 2 via a digital switch as shown in fig.2
33
The in connection of time slots i.e. switching of digital signal is normally achieved using a combination of two different modes of operation. These modes are (1) Space switching (2) Time switching In space switching mode, corresponding time slots of I/C and O/G PCM highways are interconnected. A sample in given time slot in an incoming highway is connected (switched) to same time slot of an outgoing highway. For e.g. in fig.2 the time slot 5 of incoming highway 2 is switched to time slot 5 of outgoing highway say highway 3. In this case there is no delay in switching of the sample from one highway to another highway. Since the sample transfer takes place in the same time slot of the PCM frame. In Time switching different time slots on the incoming and outgoing highways are interconnected by re-assigning the channel sequence. For e.g in fig,2 the time slot TS5 of incoming Highway2 can be connected to a different time slot TS6 of the O/G Highway2. In other words, a time switch is basically a time slot changer.
TWO DIMENSIONAL SWITCHING:Using one type of switch for large network is uneconomical. Hence to build a large network a number of stages are employed using small switches as building blocks. Such a network requires changing both the time slot and highway. Therefore the switching network usually employs both types of switches. Viz.space and time switch. This type of network is known as two dimensional networks. These networks can have various combinations of the two types of switches and denoted as TS. TST. TSST etc.
34
TST Network:As the name suggests .in a TST network there are two time stages separated by a space stage. The function of time slot changing where as the latter performs highway jumping. Let us consider a network having 4 input and 4 output highways. Each of the input and output time stages will have n time switches and the space stage will consist of an nxn cross point matrix. Thus it is possible to connect any time slot in incoming PCM to any time slot in outgoing PCM. For example let us take only four I/C and outgoing PCM highways as shown below. There will be four time switches in each T-stages and space switch will consist of 4x4 matrixes. Let us consider connecting two subscribers through this network. Let us assume central processor assigns TS4 on Hwy0 to the calling party and TS6 on Hwy3 to the called party. The central controller establishes the paths in 3 steps. To introduce greater flexibility it uses an intermediate time slot. TSX which is also known as internal timeslot. The three switching steps for transfer of speech sample of the calling party to the called party are as under:Step1 Input Time Stage (IT) TS4 Hwy0 to TSx Hwy0 Step2 Space Stage(S) TSx Hwy0 to TSx Hwy3 Step3 Output Time Stage (OT) TSx Hwy3 to TS6 Hwy3
35
As the message can be conveyed only in one direction through this path another independent path to carry the message in other direction is also established as shown in fig.3. The internal time slot for other direction is Tsy.
CONCLUSION: Digital switching has become a synonym for time division multiplex digital switching system. Digital signals are switched in two modes. Viz. time switching and space switching. In a practical digital switch a combination of both is employed to increase the traffic handling capacity of the switch at minimum cost. Among the various possible combinations TST structure is most commonly used.
SERVICES:
INTELLIGENT NETWORK (IN) SERVICES What is "IN" Services? Bhavnagar Telecom network includes "Intelligent Network" or "IN" SERVICES for its valued subscribers. This services is so intelligent in giving instant solutions to the needs of the customers, that it is called "INTELLIGENT NETWORK" (a) Free Phone Service (FPH) (b) India Telecom Card (ITC) (c) Account Card Calling (ACC) (d) Premium Rate Service (PRM) (e) Virtual Private Number (VPN) Free Phone Service (FPH) As the name suggests, the caller can make toll free calls by dialing and advertised Free phone Number. The called number pays full cost of the call. Variously known as "Green Number Services" and "Toll Free Service", it is probably the most popular IN service. It is widely used by business enterprises around the world for providing free product information and help lines. This service becomes all the more powerful when features such as Origin Dependent Routing and Time Dependent Routing are utilized. This means that the calls can be routed to different numbers depending upon the caller's location, calling time. Free phone service is provided to the IN subscriber on existing telephone connection.
36
India Telephone Card (ITC) The service allows the subscriber to place calls from any DTMF telephone (presently) to any destination number. Local / STD / ISD calls be made from a STD barred telephone also. The cost of these calls is charged to the account specified by ITC number. The telephone number from which the call originated is not charge. The user invokes the service by dialing Account Number after authentication, the allows to dial any destination local or national or international.
Account Card Calling (ACC) The customer, who may be a normal telephone subscriber, is given an account number to which all the calls made are credited to a pre determined "credit limit". Call can be made from any telephone after passing the authentication check. The caller is warned of the impending expiry of the credit limit. As opposed to the India Telephone Card Calling Service, which is a debit: Card: service, this is a "Credit" service.
Premium Rate Service (PRM) Value added professional information or advice can be accessed by any telephone subscriber but the calls are charged according to a pre determined premium rate. This service can be used by stock analysts, doctors, astrologers, NGO's help lines and certain government agencies in Jamnagar Telecom District. This number can be accessed from any point in the network. For the same PRM service, the subscriber can opt for multiple destination numbers. Virtual Private Network (VPN) This service allows the subscriber to have his own private network by utilizing the pubic network resources. It is like having PABX with Closed Groups (CUG) and class of service restrictions. A VPN subscriber can define his own dialling and routing plan between all his destination locations and configure them as if they were on a PABX, using the PSTN resources. The VPN locations (PSTN Numbers) can be a part of a CUG or outside it. The CUG members call each other by short codes which are defined in the VPN's Private Numbering Plan. VPN user can originate calls to other members of their own group (On net to on net) and calls to external public numbers (On net to off net).
37
They can also make calls into the VPN from external public numbers (Off net to On net) and also use VPN resources from any external public number in the network to call any other external public number (Off net to Off net). Authorization when be required for all the above cases except on net to on net calls. The service allows online modification of authorization code by the user.
PHONE PLUS FACILITIES Phone plus Facilities are the value added conveniences that electronic exchange offers over and above plain vanilla telephone service. No more unaccounted calls at your expense. Prevent misuse and excess billing by locking the STD / ISD / Local facility in yo8ur phone through a number code of choice. Steps for registering the code, opening and closing the STD / ISD local are given below. Use Dynamic Lock to Avoid Misuse of Your Telephone e.g. : For an E-10B Exchange at Ahmadabad ;
HOT LINE This facility provides instant calling, especially for the aged, young, or infirm. Call a preset number without dialing. Just lifting the handset and waiting for 5 seconds gets you automatically connected to the number. Within those 5 seconds, you can dial any number of choices. Hot Line calls are charged at local call rates only. You can choose to have either a one way or both ways Hot Line between any to numbers.
38
Short cut to important Numbers Now, up to 16 digit numbers can be dialed using just 2 digits. Assign 2 digit short codes for frequently called numbers, and then get connected by dialing just these. Up to 20 numbers can be called this way. Activate and use the facility in the following manner:y To enter a phone number in the short code list, dial 110 xx yyyy (xx is the 2 digit numeric of choice for phone number yyyyy). y y To call the phone number using your short code, dial 111-xx. To delete a phone number and enter a new one in the list, dial 110-xx-zzzzz (zzzzz is the new number in place of the old yyyyy).
Be away from your phone, not from your calls While away from your phone, all incoming calls on it can be directed to another local phone where you can be reached. Bring this facility into operation by dialing 114yyyyy (yyyyy: phone number where you wish to divert your calls). Dialing 115 cancels the facility. Handle up to two calls at a time If another call happens to come through while you are already busy with a call, a typical pip-pip tone will alert you to it. You can then choose to put the first caller on hold by lightly tapping the phone hook switch or pressing flash button. This brings on the dial tone, whereupon you have to dial 2 to connect the second caller. Switching back to the first caller requires you to dial 1. This facility is activated by dialling 118, and deactivated by 119.
Make sure you don't forget important moments This service helps you wake up at down, or at any other time, and remember important schedules, appointments, engagements, etc. Dial 116, and subsequently, the hours and minutes of the desired time. E.g. 116-0417 for 4:17 a. m. or 116-2115 for 9:15 p.m. at the time entered by you, the phone rings and delivers a recorded message of the time on being lifted. If there is no reply, the phone rings again after 5 minutes, and if no one picks it up the second time, the entry gets automatically cancelled. Dialling 117 also cancels the entry. Each activation of his facility is charged at the rate of two local calls.
39
SUBSCRIBER LINE MANAGEMENT:The term subscriber management in E 10B EXCHANGE define four main functions. a> Creation of subscriber number and factices. b> Interrogation of the status and facilities. c> Modification of the status and facilities. d> Deletion of or suppression of subscriber number and facilities it includes testing subscriber line also. All the above activities are carried out by means of software operation through T.TYS. So it becomes essential to know various commands and parameter used for executing the same. Each electronic subscriber connection unit (CSE) has a theoretical capacity of 1024 subscriber line equipment. These are distributed in 64 line equipment cords (XEJ). Provide in four shelves of 16 cords each. Each shelf is divided in two parts, therefore there are 8 parts numbered 0-7. On the distribution frame each part is terminated in a terminal block and hence can accommodate 128 equipments. Block 1: connection unit Block 2: Time division switching network Block 3: Control Unit Block 4: Operation & Maintenance Centre (OMC). This unit is able to handle several exchanges.
Connection Units:
The connection unit comprise basically of equipment directly connected to external interfaces of the system, subscriber lines and equipment which sends and receives audio frequency signaling samples. These units are following types: (i) (ii) (iii) (iv) (v) Local subscriber connection unit (URAL or CSEL). Remote subscriber connection unit (URAD or CSED). Multiplex connection unit (URAM). Frequency sender/receiver unit (FTA). Auxiliary equipment back (BDA).
40
located in the same premises as the exchange. The equipment number zero is how ever not used because of difficulty in addressing Zero equipment and as such a maximum of 1023 lines can be connected to this unit. It is linked to the switching network through PCM links. It provides electronic space concentration of 1024 subscriber lines on to
60, 90, or 120 digital junctions carried by 2.3 or 4 PCM links of 20.18 M bit/sec. It enables connection of dial telephones and P.B. telephones. A general structure of URAL is shown in figure below.
It provides local security communication i.e. in the event of the failure of active PCM links between the URAD and the main exchange, the E 10B system switches over this unit to security call mode. The subscriber line is alerted by a short text recorded announcement followed by a special dial done (400 Hz continuous non-modulated). This dial tone is provided by the URAD (CSED) itself. The CSED subscribers can obtain to access to the emergency service like police, ambulance, and fire by dialing two digits. Out of the 1024 equipments provided in the CSED. 6 equipments are used for these emergency services. A general schematic of URAD is shown in the figure.
The main functions of subscriber unit connection unit are: (i) (ii) Connection and power feed on subscriber lines and sending of ringing current. Transmission of loop state change indication to the control units, transmission of dialed digits and transmission of battery reversals or remote metering pulses to appropriate units. (iii) (iv) Cyclic units of equipment to identify calling subscriber. Search for free out going routes (physical path within) when the URA between the subscriber line equipment and the time slot allotted to this subscriber. (v) (vi) Analogue to digital conversion. Traffic observation counters.
42
(vii)
(viii) A subscriber connection unit is housed in a single rack. There are two types of
PCBs for the subscriber equipment,--PCBs for the sixteen ordinary subscriber and PCBs for eight discriminated subscriber (home metering battery reveal). These PCBs are housed in four shelves. The maximum number of the boards in a rack is 64.
43
An automatic exchange (E-10 B) comprises of at least two ETAs operating on load sharing basis, the maximum number of ETAs being sixteen.
Switching Network:SThe time division switching network is a three stage system (time, space, time).
It provides a 4W switching between the time slot allocated to the calling party and the time slot allocated to the called party. For one call two samples connecting (4W) in the switching network is shown in figure:-
(i)
Speech samples (a) from the time slot T of the incoming network line (LRE) associated with the calling subscriber are switched to the time slot J of the outgoing network lines (LRS) associated with the called subscriber.
45
(ii)
Speech samples (b) from the time slot J of the incoming network (LRE) associated with the called subscriber are switched to the time slot I of the outgoing network line (LRS) associated.
Each time switch handles 16 PCM links (LRE+LRS) and four time switches catering 4*16= 64 PCMs are contained in one switching network rack. A complete switching network comprises six identical rack for connecting 384 PCMs. A diagram showing the structure of a switching network is shown in figure below:-
Controls unit:
The control unit are partly based on dedicated mini-computers and used to carry out all the switching operations required to set up and release the connection between subscribers and/or circuits. These units can be classified as follows:46
Marker (MQ) Switching network control unit (UGCX) Multi register (MR) Charging unit (TX) To ensure uninterrupted telephone service, these units are duplicated and operate on load sharing basis.
Management unit:
Standby charge recording unit (DSF)
47
Multi-register (MR): The multi-registers is charging of the setting up and releasing of calls. It is as the heart of the system and is the only control unit which can take initiative and sends orders to other units in real time. It has access to all data from subscriber and trunk circuits (E&M wires) and to all units in the exchange. The main function of multi-registers involves: Servicing new call and on hook conditions on subscribers lines and circuits, detected by connections unit. Releasing subscriber lines and circuits. Receiving and forwarding address information. Receiving and sending signals from/to connection units. Ordering the switch network to connect or disconnect the two parties. Ordering the transmission of various tones. Requesting the translator to determine the connection address of the subscriber line or circuit at the exchange, on the basis of the directory number.
48
Translator (TR): The transistor provides the multi-registers on request, with data on subscribers and trunks required to set up and release of calls. Data (categories, correspondence between directory numbers and subscriber or trunk equipment in the exchange) are held in TR lines. This data may be written, detected or modified from the operating requirements. The translator executes the following operations:y Seeking subscriber lines or circuit class of service when a new call or on hook condition is detected. y y Translating prefixes or the first digits dialed by the calling party. Translating called party directory number in to equipment are circuit number. y Handling translation operations for chaining and overflow routing functions. y Managing additional services.
It sends detailed billing manages and observation messages to stand by charge recording unit DSF where the OMC is down or unavailable. It sends subs. Meter readings (periodically demand from OMC), detailed billing message and traffic observation message to OMC. It stores traffic observation data. Each charging unit can be configured as follows: * 1000 charging register of 512 bits, or 2000 charging register of 256 bit, or combination of 256 and 512 bit charging registers. Each charging unit can, therefore handle upto 2000 calls simultaneously. Each exchange has two charging units operating on load-sharing basis. Charging registers compute the charge for given telephone call. At the end of the calls, the subscriber meter is incremented simultaneously in both charging units and these two values (which should be identical) are read periodically by the OMC.
50
Message from OMC exchange units: Operating message (subscriber, line creation, circuit creation, etc.). Unit, positioning message. Maintenance message. Control message addressed to test modules. Message from exchange units to OMC: Detailed billing and traffic observation messages. Answer messages. Fault messages. Messages specifying the number of calls in progress for each type of traffic. Constant or temporary observation messages. Routing text messages. A single monitoring unit is provided in each exchange. Base Time: The time base supplies basic time signals to various exchange units for synchronizing and coordinating operation which are necessary in a time division switching system. Each exchange has its own time base which is not duplicated and is therefore constructed from components offering high level of operating security. It operates independently but can be divided by an external signal. The time base generates to sets of signal A set of four signals (2W, 28, h, ti) distributed to all exchange units except switching network and the switching network control unit. A set of two signals (2g, Sm) sent to switching network control unit. A basic signal is sent by the time base. The following table gives the characteristics each signal:
51
Signal name
2W 4.096 M-bits/S
Characteristics
Twice the frequency of link
ti
Each time slot or signal ti contains a binary no. [0-31] indicating the rank of time slot in the frame.
2g Sn
6.144M bit/sec. time signal used in time division. Switching network only 500 Hz.
A basic signal sent by the time base must reach other exchange units at the same moment. Since propagation time cannot be ignored, it is essential to use game cable length for signal distribution. For his region the time base is located at the centre of the exchange. The time base unit occupies full rack.
52
The operating and maintenance staff dialogues are the OMC via tele printers, serial printers and displays. That a maximum number of terminals are 64. They can be located near the OMC are remotely by using of modems. One OMC can handle up to 5 E-10B Exchanges. A general structure of OMC is shown in figure.
Traffic: The switching network houses up to 384 PCM links, of which 16 are generally
used by frequency receiver. The balance 368 multiply by 30 PCM links (incoming and outgoing) rename for subscriber and trunk units i.e. 11040 LF channels. With an average of 0.7 erlang per channel, we see that the maximum traffic capacity of the switching
53
network is around 3800 erlang. The traffic capacity of the control units, particularly the multi register, depends upon several parameters like type of signaling, on circuits, types of subscriber dialing, percentage of successful call, percentage of incomplete dialing etc. Average duration for mixed call: Average busy time of register for a mixed call is > 4 (very roughly) if the control units in the normal conditions handle the maximum traffic handled by the switching network. Subscriber facilities: The E-10B system offers number of facilities to its subscriber. There are:(i) (ii) (iii) (iv) (v) (vi) (vii) (viii) (ix) (x) (xi) (xii) (xiii) (xiv) (xv) (xvi) Hot line Detailed billing Absent service PBX Barred access Malicious call tracing Free phone line Subscriber with home meter Push button telephone Priority line Outgoing only subscriber Incoming only subscriber Abbreviated dialing Temporary transfer Recorded call Conference call
(xvii) Ring back facility (xviii) Automatic alarm call Creation facilities like P.B. telephone short code dialing call transfer conference calls, automatic alarm calls where not possible in electromechanical exchanges.
54
E-10B Environment:
Switch ROOM: E-10B racks are installed in suites of 11 racks (maximum). A fully equipment exchanges contain between 4 and 7 suites. For a 7 suites exchange a room of 12.5 m. 11 m. is required. OMC ROOM: Two rooms are required, the first for OMC equipment, the second for the operating terminals. Each of them requires an area of some 40mm. Power: E-10B Exchange: An E-10B Exchange needs two power supplies: y 48v DC Supply: This current is obtained from rectifiers and batteries. It supplies to the subscriber lines and DC/DC converters (: or 5V, 12V and 24V) housed in each racks. For a 10000 local subscriber line exchange, the power consumption is about 500A/18V. y OMC: The OMC needs 220V AC inverter supply and consumes some 4KVA in stabilized state. Two 6KVA inverters are generally used. The available power can supply part of the operating terminals. A 20A/48V DC supply is required for the Message 220V AC Inverter supply: This current supplies the standby charge recording unit. One or two 1KVA inverters are used.
Transmission Equipment Rack (ETM). Air-Condition: In the exchange room, cool air (17) is blown up into the racks from
beneath the tales floor. The relative humidity must be between 30 . in the OMC room, cool and is blown in for the ambient condition. The temperature regulation point is 22 with a relative humidity.
55