DISEO DE ESCALERA 2 tramo

DATOS P:paso CP:contra paso t:espesor del cuello B:Ancho de la ecalera L: Lon. de esc. L 1 : Lon. de esc. Descanso

P=0.30m

P = CP = t = B= COS()= L= L1= S/C=

2400 0.3 0.165 0.17 1.5 0.876 2.7 3.35 400

kg/cm m m m m M M
kg/m kg/m
Cp=0.18m

t=L/20 L/25

S/C=acab. 100 recub.= 4 F'c= 175 fy=. 4200 1)METRADO DE CARGAS a). Descanso carga muerta peso propio= Acabados= CpxBx= BxS/Cacab=.

cm
kg/m kg/m

594 150 WD = 744 Kg/m

Sobrecarga =

S/CxB= WL= 600 Kg/m

CARGA ULTIMA Wu=1.5xWd+1.8xWL Wu= 2061.6 Kg/m

b). Tramo inclinado peso propio= 2.4 b (Cp/2+ t/cos) peso propio= 995.46 Kg/m Acabados= Bx S/C acab=. WD = Sobrecarga S/C=BX400 WL= CARGA ULTIMA Wu=1.5xWd+1.8xWL Wu= 2)ESQUEMA ESTRUCTURAL
L=2.70m L2=3.32 m

995.46 Kg/m 150 Kg/m 1145.46 Kg/m

600 Kg/m

2623.6 Kg/m

Estado de cargas
WL Wddes L=2.70m L2=3.32m

M1 M2

MM 3 3 M4

M5

M 1 =1/16 a 1/12 WL 2 M 2 =1/10 WL


2

M1= M2=

1195.3965 1912.6344

M 3 =1/9 W((L 1 +L 2 )/2) 2 M 4 =1/10 WL 2 2 M 5 =1/16 a 1/12 WL 2


2

M3= M4= M5=

1707.7704 2313.6306 1928.0255

como es hiperesttico clculamos los momentos


Momento (+)= Momento (-)= Momento (-)=

1.93 tn-m 2.31 tn-m 1.7 tn-m


d=t-(recub--/2)

Clculo del peralte considerando 5/8= d= 1.29 cm 12.355 cm

CALCULO DEL AREA DE ACERO (-)


Mu=Kuxbxd

10.0887 En la tabla Ku vs para f'c=175kg/cm


Ku= = As = rBd/100 As = Verificacin de acero minimo As min = 0.0018 Bd Asmin = As dis = refuerzo longitudinal 3/8"= Smax<=45cm 3t 1/2"= 5/8"= 3/4"= Alternativa 1 Alternativa 2 Alternativa 3 Alternativa 4
USAR 3/8" @ USAR 1/2" @ USAR 5/8" @ USAR 3/4" @

0.0028

5.1891

cm

2.2239 5.1891

cm cm

0.71 cm2 1.29 cm2 2 cm2 2.84 cm2 cm cm cm cm n de varillas n de varillas n de varillas n de varillas
5.00varillas

14 25 39 45

7 5 3 2

USAR ALTERNATIVA N1

USAR 1/2" @25cm

Astemp. =0.0018xbxt Astemp. = 3/8 =0.71 cm Alternativa 1


USAR 3/8" @ una sola capa

2.2239

32 cm

n de varillas

CALCULO DEL AREA DE ACERO (+)


Mu=Kuxbxd Ku= 8.4291 En la tabla Ku vs para f'c=175kg/cm = As = rBd/100 As = Verificacin de acero minimo As min = 0.0018 Bd Asmin = As dis = refuerzo longitudinal 3/8"= Smax<=45cm 3t 1/2"= 5/8"= 3/4"= Alternativa 1 Alternativa 2 Alternativa 3 Alternativa 4
USAR 3/8" @ USAR 1/2" @ USAR 5/8" @ USAR 3/4" @

0.0024

4.4478

cm

2.2239 4.4478

cm cm

0.71 cm2 1.29 cm2 2 cm2 2.84 cm2 cm cm cm cm n de varillas n de varillas n de varillas n de varillas
4.00varillas

16 29 45 45

6 4 2 2

USAR ALTERNATIVA N1

USAR 1/2" @25cm

Astemp. =0.0018xbxt Astemp. = 3/8 =0.71 cm Alternativa 1


USAR 3/8" @ una sola capa

2.2239

32 cm
USAR 3/8" @30cm

n de varillas

VERIFICACION POR CORTE (ms crtico)


V =WuL/2-l(Ma+Mb)/L V=

2.056730411 TN
Wu WA x W

M+WuxX/2-V=0 X= Ld=x+d= CHEQUEO POR CORTE Vc=0.53xf'cxdxb Vc= 12993.58234 tn


0.80000 0.92355

okey

CONTRA PASOS MINIMOS

Escaleras secundaria 18-20 Escaleras monumentales 13-15 Escaleras en edificios 15-17.5 Escalera en locales comerciales 18cm
B ANCHO MINIMOS TIPO DE EDIF. B(m)

_Viviendas _Auxiliares o de servicio _Caracol _Edif. De ofocinas _locales comerciales

1 0.7 0.6 1.2 1.3

SOBRECARGAS RNC TIPO DE EDIF. S/C (kg/m)

_Viviendas y edif. Comerciales

200

_Viviendas y edif. residenciales250-300 _Edif. Pblicos 400 _Edif. De ofocinas y tribunas 500 _Acabados 100

DISEO DE ESCALERA 1 tramo


DATOS P:paso CP:contra paso t:espesor del cuello B:Ancho de la ecalera L: Lon. de esc. L 1 : Lon. de esc. Descanso

P=0.30m

P = CP = t = B= COS()= L= L1= S/C=

2400 0.3 0.165 0.17 1.5 0.876 3.9 1.5 400

kg/cm m m m m M M
kg/m kg/m
Cp=0.18m

t=L/20 L/25

S/C=acab. 100 recub.= 4 F'c= 175 fy=. 4200 1)METRADO DE CARGAS a). Descanso carga muerta peso propio= Acabados= CpxBx= BxS/Cacab=.

cm
kg/m kg/m

594 150 WD = 744 Kg/m

Sobrecarga =

S/CxB= WL= 600 Kg/m

CARGA ULTIMA Wu=1.5xWd+1.8xWL Wu= 2061.6 Kg/m

b). Tramo inclinado peso propio= 2.4 b (Cp/2+ t/cos) peso propio= Acabados= 995.46 Kg/m Bx S/C acab=. 995.46 Kg/m 150 Kg/m

WD = 1145.46 Kg/m Sobrecarga S/C=BX400 WL= CARGA ULTIMA Wu=1.5xWd+1.8xWL Wu= 2)ESQUEMA ESTRUCTURAL
L=3.90m L2=1.50m

600 Kg/m

2623.6 Kg/m

Estado de cargas
WL Wddes L=3.90m L2=1.50m

M1 M2

M3 M4

M5

M 1 =1/16 a 1/12 WL 2 M 2 =1/10 WL


2

M1=
2

2494.1 3990.56 3563.13 463.86 386.55

M2= M3= M4= M5=

M 3 =1/9 W((L 1 +L 2 )/2) M 4 =1/10 WL 2 2 M 5 =1/16 a 1/12 WL 2


2

como es hiperesttico clculamos los momentos


Momento (+)= Momento (-)=

2.49 tn-m 3.99 tn-m

Momento (-)=

1.7 tn-m
d=t-(recub--/2)

Clculo del peralte considerando 5/8= d= 1.29 cm 12.355 cm

CALCULO DEL AREA DE ACERO (-)


Mu=Kuxbxd Ku= 17.4259 En la tabla Ku vs para f'c=175kg/cm = As = rBd/100 As = Verificacin de acero minimo As min = 0.0018 Bd Asmin = As dis = refuerzo longitudinal 3/8"= Smax<=45cm 3t 1/2"= 5/8"= 3/4"= Alternativa 1 Alternativa 2 Alternativa 3 Alternativa 4
USAR 3/8" @ USAR 1/2" @ USAR 5/8" @ USAR 3/4" @

0.005

9.26625

cm

2.2239 9.26625

cm cm

0.71 cm2 1.29 cm2 2 cm2 2.84 cm2 cm cm cm cm n de varillas n de varillas n de varillas n de varillas
8.00varillas

8 14 22 31

13 8 5 3

USAR ALTERNATIVA N1

USAR 1/2" @14cm

Astemp. =0.0018xbxt Astemp. = 3/8 =0.71 cm Alternativa 1


USAR 3/8" @ una sola capa

2.2239

32

cm

n de varillas

CALCULO DEL AREA DE ACERO (+)


Mu=Kuxbxd

10.8748 En la tabla Ku vs para f'c=175kg/cm


Ku= =

0.003

As = rBd/100 As = Verificacin de acero minimo As min = 0.0018 Bd Asmin = As dis = refuerzo longitudinal 3/8"= Smax<=45cm 3t 1/2"= 5/8"= 3/4"= Alternativa 1 Alternativa 2 Alternativa 3 Alternativa 4
USAR 3/8" @ USAR 1/2" @ USAR 5/8" @ USAR 3/4" @

5.55975

cm

2.2239 5.55975

cm cm

0.71 cm2 1.29 cm2 2 cm2 2.84 cm2 cm cm cm cm n de varillas n de varillas n de varillas n de varillas
5.00varillas

13 23 36 45

8 5 3 2

USAR ALTERNATIVA N1

USAR 1/2" @13cm

Astemp. =0.0018xbxt Astemp. = 3/8 =0.71 cm Alternativa 1


USAR 3/8" @ una sola capa

2.2239

32

cm

n de varillas

USAR 3/8" @30cm

VERIFICACION POR CORTE (ms crtico)


V =WuL/2-l(Ma+Mb)/L V=

3.65712595 TN
Wu
WA

WB

M+WuxX/2-V=0 X= Ld=x+d= CHEQUEO POR CORTE Vc=0.53xf'cxdxb Vc= 12993.5823 tn


0.80000 0.92355

okey

CONTRA PASOS MINIMOS

Escaleras secundaria 18-20 Escaleras monumentales 13-15 Escaleras en edificios 15-17.5 Escalera en locales comerciales18cm
B ANCHO MINIMOS TIPO DE EDIF. B(m)

_Viviendas _Auxiliares o de servicio _Caracol _Edif. De ofocinas _locales comerciales

1 0.7 0.6 1.2 1.3

SOBRECARGAS RNC TIPO DE EDIF. S/C (kg/m)

_Viviendas y edif. Comerciales

200

_Viviendas y edif. residenciales 250-300 _Edif. Pblicos 400 _Edif. De ofocinas y tribunas 500 _Acabados 100

DISEO DE ESCALERA APOYADA TRANSVERSALMENTE


DATOS P:paso CP:contra paso t:espesor del cuello B:Ancho de la ecalera L: Lon. de esc. L 1 : Lon. de esc. Descanso P = P' = CP = 2400 0.1 0.1929378 0.165 m kg/cm m
Cp=0.16m P'=P/COS t=ASUMIDO

P=0.30m

t = 0.17 m t 1 = 0.3279943 m TM= 0.3289971 B= 1.5 m COS()= Li= S/C= 0.518 3 500
kg/m

S/C=acab. 100 kg/m recub.= 4 cm F'c= 210 kg/m fy=. 4200 kg/m 1)METRADO DE CARGAS

B=1.25

b). Tramo inclinado peso propio= tmx 2.4 peso propio= 789.59 Kg/m Acabados= Bx S/C acab=. WD = Sobrecarga S/C=BX400 WL= CARGA ULTIMA Wu=1.5xWd+1.8xWL 500 Kg/m 789.59 Kg/m 100 Kg/m 889.59 Kg/m

Wu= W'u=
W'u x paso=

2412.3 Kg/m 648.0 Kg/m 125.0 Kg/m

2)ESQUEMA ESTRUCTURAL
L=1.55m

Wu=

Mmax Momento (+)=W'ux L/8= Momento (-)=W'ux L/24=

35.164787 Kg-m 11.721596 Kg-m

como es hiperesttico clculamos los momentos


Momento (+)= Momento (-)=

0.0351648 tn-m 0.0117216 tn-m

Se disea como viga triangular con la carga perpendicular a la inclinacion de la esc.

CALCULO DEL PERALTE d


h'=P+t 1

h'= h= d=

10.3660343 10.3660343 7 cm

CALCULO DEL AREA DE ACERO (-)


Mu=Kuxbxd

2.3922 En la tabla Ku vs para f'c=175kg/cm


Ku= = As = rBd/100 As = 2.1

0.002

cm

Verificacin de acero minimo As min = 0.0018 Bd Asmin = As dis = refuerzo transversal 3/8"= Smax<=45cm 3t 1/2"= 5/8"= 3/4"= Alternativa 1 Alternativa 2
USAR 3/8" @ USAR 1/2" @

0.126 2.1

cm cm

0.71 cm2 1.29 cm2 2 cm2 2.84 cm2 n de varillas n de varillas


3.00varillas

30 cm 30 cm

3 2

USAR ALTERNATIVA N1

USAR 3/8" @30cm

refuerzo longitudinal Astemp. =0.0018xbxt Astemp. = 3/8 =0.71 cm Alternativa 1


USAR 3/8" @ una sola capa

1.26

45 cm

n de varillas

CALCULO DEL AREA DE ACERO (+)


Mu=Kuxbxd

3.7196 En la tabla Ku vs para f'c=175kg/cm


Ku= = As = rBd/100 As = Verificacin de acero minimo As min = 0.0018 Bd Asmin = As dis = 0.243101645 0.525 0.525

0.0005

cm

cm cm

refuerzo transversal 3/8"= 0.71 cm2

Smax<=45cm 3t

1/2"= 5/8"= 3/4"=

1.29 cm2 2 cm2 2.84 cm2 n de varillas n de varillas 4 3

Alternativa 1 Alternativa 2

USAR 3/8" @ USAR 1/2" @

45 cm 45 cm

VERIFICACION POR CORTE (ms crtico)


V =WuL/2-l(Ma+Mb)/L V=

3.60283371 TN
Wu WA x W

M+WuxX/2-V=0 X= Ld=x+d= CHEQUEO POR CORTE Vc=0.53xf'cxdxb Vc= 1.03729172 tn


1.72549 1.79549248

poner estribo

OYADA TRANSVERSALMENTE

MEDIDAS SEGN REGLAMENTO


CONTRA PASOS MINIMOS

Escaleras secundaria 18-20 Escaleras monumentales 13-15 Escaleras en edificios 15-17.5 Escalera en locales comerciales 18cm
B ANCHO MINIMOS TIPO DE EDIF. B(m)

_Viviendas _Auxiliares o de servicio _Caracol _Edif. De ofocinas

1 0.7 0.6 1.2

_locales comerciales

1.3

SOBRECARGAS RNC TIPO DE EDIF. S/C (kg/m)

_Viviendas y edif. Comerciales 200 _Viviendas y edif. residenciales250-300 _Edif. Pblicos 400 _Edif. De ofocinas y tribunas 500