Professional Documents
Culture Documents
Upon completion of this course, you will be able to: Know the functions and features of BTS Master the BTS hardware structure
Page 2
References
BTS3012 Technical Manual BTS3012 Installation Manual BTS3012 User Manual
Page 3
Page 4
Location
Um Interface PSTN ISDN PSPDN
TUP,ISUP
MSC/VLR
BTS3012 BTS3012
MS BTS3012 OMC
MAP
HLR/AUC/EIR
SMC/VM
MS: Mobile Station HLR: Home Location Register MSC: Mobile Switching Center VM: Voice Mailbox
BTS: Base Transceiver Station AUC: Authentication Center VLR: Visitor Location Register
BSC: Base Station Controller EIR: Equipment Identity Register SMC: Short Message Center
Page 5
coverage
Page 6
Page 7
Page 8
Hardware structure
Abis Interface Monitor TBUS/DBUS/CBUS BITS Um Interface
Extension cabinet
DATU TMA TMA DTRU DAFU TMA TMA DTRU FH_BUS TMA TMA DTRU DAFU DAFU MS
E1
M E L C
DTMU fiber
E1 Metro 100 DEMU
NFCB DATU
Common subsystem
Forepart of RF Subsystem
Page 9
Power and E MC
D C O M
D D P U
D C O M
Wiring
D D P U
D C O M
D D P U
D T R U
D T R U
D T R U
Wiring FAN Air Inlet
D T R U
D T R U
D T R U
D T M U
D T M U
D E M U
D C S U
D C C U
D A T U
Page 10
DDPU
DCOM DATU DMLC DELC DSAC DCSU DEMU
DCTB
FAN Box
Page 11
Common Subsystem
DTMU Transmission timing& management unit for DTRU BTS DEMU Environment Monitoring Unit for DTRU BTS DCSU Combined cabinet Signal connection Unit for DTRU
BTS
DCCU Cable Connection Unit for DTRU BTS
DATU Antenna and TMA control unit for DTRU BTS
Page 12
Functions of DTMU
Providing the external GPS input, the BITS synchronized clock
input
Providing 4-route or 8-route E1 inputbackup between the
Page 13
Structure of DTMU
DTMU LMT MMI CBUS2 MCU
BSC
BIU
DTRU
Page 14
Indicators on DTMU
Indicator Color Description Status RUN Green Indicates Slow flash (0.25 Hz) operation Slow flash (0.5 Hz) Fast flash at uncertain intervals Off ACT Green Indicates Off whether the On board is active or standby PLL Green Indicates the Off clock status On Fast flash (4 Hz) Fast flash (1 Hz) LIU1 Green Indicates the Off transmission status of E1 On port 1 and port 5 Fast flash (4 Hz) Meaning OML is blocked Normal BSC data loading Power failure of the board Standby Active
DTMU RUN ACT PLL LIU1 LIU2 LIU3 LIU4 SWT ALM
Abnormal Free-run Pull-in Lock E1 port 1 is normal when SWT is out E1 port 5 is normal when SWT is on E1 port 1 near end alarm occurs when SWT is out E1 port 5 near end alarm occurs when SWT is on E1 port 1 remote end alarm occurs when SWT is out E1 port 5 remote end alarm occurs when SWT is on
RST MMI
Page 15
Indicators on DTMU
Indicator Color Description Status LIU2 Green Indicates the Off transmission status of E1 port 2 and port 6 On Fast flash (4 Hz) Off Meaning E1 port 2 is normal when SWT is out E1 port 6 is normal when SWT is on E1 port 2 near end alarm occurs when SWT is out E1 port 6 near end alarm occurs when SWT is on E1 port 2 remote end alarm occurs when SWT is out E1 port 6 remote end alarm occurs when SWT is on E1 port 3 is normal when SWT is out E1 port 7 is normal when SWT is on E1 port 3 near end alarm occurs when SWT is out E1 port 7 near end alarm occurs when SWT is on E1 port 3 remote end alarm occurs when SWT is out E1 port 7 remote end alarm occurs when SWT is on E1 port 4 is normal when SWT is out E1 port 8 is normal when SWT is on E1 port 4 near end alarm occurs when SWT is out E1 port 8 near end alarm occurs when SWT is on E1 port 4 remote end alarm occurs when SWT is out E1 port 8 remote end alarm occurs when SWT is on LIU1 to LIU4 indicate the transmission status of E1 port 1 to 4. LIU1 to LIU4 indicate the transmission status of E1 port 5 to 8. No hardware alarm Hardware alarm
DTMU RUN ACT PLL LIU1 LIU2 LIU3 LIU4 SWT ALM
LIU3
LIU4
RST MMI
SWT
ALM
Red
Alarm indicators
Off On
Page 16
Interface T2M
FCLK
T13M MMI
SMB (female)
SMB (female) RJ45
Page 17
Functions of DEMU
The DEMU is placed in slots 2 to 4 and slot 7 of the common subrack with
the DATU. The DEMU is an optional module. There is maximum one DEMU under full configuration.
Monitoring variations in the smoke, water, temperature, humidity, infrared,
CBUS3
Page 18
Functions of DCSU
The Combined Cabinet Signal
Connection Unit for DTRU BTS (DCSU) is placed in slot 5 of the common subrack, which is located in the lower part of the cabinet. There is only one DCSU and it is mandatory
The DCSU transfers signals for
DTMU
DCMB
DEMU
the combined cabinet and cabinet group between the common subrack and the cabinet top subrack
DATU
Page 19
DCSU
Silk- Screen
Type
Description
CC_OUT
MD64 (female)
CC_OUT
CC_IN
MD64 (female)
CC_IN
To_DTRB
MD64 (female)
TO_DTRB
TOP2
DB26 (female)
TOP2
Page 20
Switch of DCSU
GM51DCSU VERB SW6 SW9
SW7 SW10 SW8
SW5
Page 21
Functions of DCCU
The DCCU is placed in slot 6 of
DTMU
common subrack
Providing EMI filtering
DATU
Page 22
POWER
3V3
TO_TOP1
POWER
Page 23
Functions of DATU
DATU
common subrack with the DEMU. It is optional and there are maximum two DATUs
Transmitting the remote electrical tilt unit (RET)
control signals
Feeding the TMA Communicating with the DTMU through CBUS3 for
ANT4 ANT5
Page 24
CKB2
D M L C
D E L C
D E L C
D S A CKB1 C
Page 25
DCF
Function of DMLC
DMLC
subrack with the DELC. There is only one DMLC and it is optional DMLC
Thirty-two-route Boolean value input Six-route Boolean value output Four-route analog input
SWOUT SWIN
Smoke/water/access
Page 26
Function of DELC
The DELC is placed in slots 0 to 2 of the cabinet
DELC
TR
Page 27
Function of DSAC
DSAC
alarm
Access protection of BITS clock input
Page 28
SYNC
EAC
COM1
S1+S1-S2+S2-
COM 2
DTRB
Page 29
Functions of DTRU
RF subsystem transmit part. Converts the basband signals on the two
TRXs to the RF signals. Supports up-frequency conversion of the signals and RF frequency hopping.Filters, amplifies, and outputs the combined signals
RF subsystem receive part.Devides and modulates the RF signals on the
decoding, interleaving and de-interleaving, modulation and demodulation.Supports voice fax services.Supports data services in Phase II, GPRS services, and EDGE services.Supports transmit diversity and 4-way receive diversity.Amplifies the output power
Page 30
DTRU DPAU
DTMU DBRU
DAFU
DTPS 48V DC
Page 31
Indicators on DTRU
Indicator RUN Color Green Description Indicates the running and power-on of the DTRU Status On Off Meaning There is power supply or the board is faulty. There is no power supply and the board is faulty. The board is starting.
DTRU TX1 IN1 TCOM IN2 TX2 RST RUN ACT ALM RF_IND RXM1 RXD1 RXM2 RXD2 PWR
ACT
Green
ALM
Red
Indicates alarm
RF_IND
Red
RF interface indicators
Slow flash (0.25 Hz) Slow flash (0.5 Hz) The board is running. Fast flash (2.5 Hz) The DTMU is sending configuraiton parameters to the DTRU. On The board is running (the DTMU sends configuration parameters to the DTRU correctly and the cell is starting). All the channels on the two carriers can work normally. Off Communication between DTRU and DTMU is not set up Slow flash (0.5Hz) Only parts of the logic channels are working normally (including after TRX mutual aid). On (including Critical alarm occurs to the board. high-frequency flash) Off The board is normal. On Standing wave alarm Off Normal Slow flash (0.5 Hz) RL alarm
Page 32
Indicators on DTRU
Interface TX1 Type N (male) TX1 output signals: Description
TX1 IN1 TCOM IN2 TX2 RST RUN ACT ALM RF_IND RXM1 RXD1 RXM2 RXD2 PWR DTRU
Page 33
Page 34
TX
IN1 TCOM IN2 TX2
combiner
TRX0
RXM1 RXD1
TX
RXM2 RXD2
TRX1
Page 35
TCOM
IN2 TX2
combiner
TRX0
TX
TRX1
Page 36
Same phase
TX
combiner
TRX0
TX2
TX
TRX1
Page 37
TX
TRX0
TX
TRX1
Page 38
Page 39
TRX0
RXM1
divider
RXD1
TX divider
RXM2 RXD2
TRX1
Page 40
TRX0
RXM1
divider
RXD1
divider
TX
RXM2 RXD2
TRX1
Page 41
TRX0
RXM1
divider
RXD1
divider
TX
RXM2 RXD2
TRX1
Page 42
TRX0
RXM1 RXD1
divider TX divider
RXM2 RXD2
TRX1
Page 43
Functions of DTRB
The DTRB is placed in the DTRU
between the DCSU and the DTRU. All the onsite signals are provided to the DCSU through the DTRB
DTRB
Page 44
D C
NBBI
D D P U
D C O M
D D P U
D C O M
D D P U
O M
Page 45
Functions of DDPU
The DDPU is intermixed with the DCOM in the DAFU subrack
of the forepart of RF subsystem. It is indispensable. Generally, the number of DDPU is one at least and three at most. Without the DCOM, there can be at most six DDPUs
Sending multi RF signals from the transceiver in the DTRU to
Page 46
duplexer
divider
duplexer
divider
TXA RXA1 RXA2 RXA3 RXA4 TXB RXB1 RXB2 RXB3 RXB4
Page 47
Indicators on DDPU
Indicator RUN Color Description On Status Meaning There is power supply and the board is faulty.
ANTB ANTA DDPU RUN ALM VSWRA VSWRB
Off
Slow flash (0.5 Hz) Fast flash (2.5 Hz)
ALM
Red
Indicates an alarm
COM
Off
Slow flash (0.5 Hz) VSWRA Red Indicates a standing wave alarm of Channel A Slow flash (0.5 Hz) On Off VSWRB Red Indicates a standing wave alarm of Channel B Slow flash (0.5 Hz) On Off
No fault
The board is starting or loading the newest application programs Standing wave alarm occurs to Channel A Standing wave critical alarm occurs to Channel A No standing wave alarm occurs to Channel A Standing wave alarm occurs to Channel B Standing wave critical alarm occurs to Channel B No standing wave alarm occur to Channel B
POWER
RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 RXB3 RXB4 TXB TXA
Page 48
Interface on DDPU
ANTB
Interface Type COM DB26 (female) POWER 3V3 TXA N (male) TXB RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 RXB3 RXB4 ANTA ANTB N (male) SMA (female) SMA (female) SMA (female) SMA (female) SMA (female) SMA (female) SMA (female) SMA (female) DIN (female) DIN (female)
Description Sends to the DDPU control signals, communication signals, clock signals and subrack number Power supply input Input of the TX signals sent from the DTRU Input of the DCOM combining signals Input of the TX signals sent from the DTRU Input of the DCOM combining signals Main 1 output port Main 2 output port Main 3 output port Main 4 output port Diversity 1 output port Diversity 2 output port Diversity 3 output port Diversity 4 output port RF jumper port RF jumper port
COM
POWER
RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 RXB3 RXB4 TXB TXA
Page 49
Functions of DCOM
DCOM
maximum three DCOMs. The DTRU combines two carriers into one channel. The DCOM is required when the DTRUs are insufficent
The DCOM combines the 2-route DTRU
TX-COM
TX1
TX2
Page 50
Interfaces on DCOM
Description For indentification of the board type of DCOM and on-site status Output of combining signals from the DCOM to DDPU TX signal input from the DTRU to DCOM
TX2
N (male)
Page 51
ventilation and dissipation for the common subrack, the DTRU subrack, and the DAFU subrack
The FAN Box is mandatory with four independent axial flow fans. The
fans' speed and running status are controlled by the Fan Controlling and Monitoring Board
STATE
FAN PWR
COM
Page 52
Indicator STATE
Color Green
Meaning Communication between the NFCB and the DTMU is abnormal. There is no alarm Alarm occurs to the board
Red
Green
Orange (red and green) Green or red or orange
Page 53
Page 54
the signal flow of the service and signaling include DL Signal Flow UL Signal Flow Signaling Processing Signal Flow Clock Signal Flow Combined Cabinet Signal Flow
Page 55
DL Signal Flow
Um
MS
Antenna Feeder
D D P U
D T R U
D T M U
Abis
BSC
BTS3012 Cabinet
Page 56
DL Signal Flow
The DL signal flow includes the following steps:
The DTMU receives the service data from the BSC, exchanges and processes it, and then transfers it to the DTRU The DTRU performs digital filtering, up conversion, and filter amplification of the signals and sends the signals to the DDPU The duplexer in the DDPU filters the signals sent from the DTRU and transmits the signals through antennas and feeders
Page 57
UL Signal Flow
Um
MS
Antenna Feeder
D A F U
D T R U
D T M U
Abis
BSC
BTS3012 Cabinet
Page 58
UL Signal Flow
The UL signal flow includes the following steps:
The antenna receives the signals transmitted from the MS. After being amplified by the TMA, the signals are transmitted to the DDPU through the feeder.The TMA is optional. It is used to compensate the feeder loss and enhance receiver sensitivity of the DDPU antenna port The DDPU receives the signals and transmits the signals to the DTRU after they are filtered by the duplexer and amplified by the LNA The DTRU receives the signals and transmits the signals to the DTMU after amplification and down conversion. The DTMU then transmits the signals to the BSC through the Abis interface
Page 59
BSC
Abis DTMU
DTRU
DDPU
BTS3012
Page 60
The Abis interface board receives the signaling data from the BSC and transmits the data to the DTMU The DTMU performs decision and processing on the signaling and transmits the signaling to the DTRU and DDPU The DTRU and DDPU report board status to the DTMU The DTMU obtains the status of the BTS3012 by collecting and analyzing the status of all boards and transmits the information to the BSC through the Abis interface
Page 61
A-bis DTMU
Clock distribution cable between cabinets
Page 62
The external reference clock is transmitted to the clock module in the DTMU through the Abis interface The clock module performs phase lock and frequency division on the clock signals to generate different clock signals for BTSs The clock signals are transmitted to the modules in the main cabinet such as the DTRU and the DDPU The clock signals are transmitted to the modules in the slave cabinets through the clock distribution cable
Page 63
Page 64
Jumper
Feeder
Page 65
Antenna
In mobile communications systems, the antenna consists of an
Feeding network
Page 66
Antenna
BTS3012 antennas are classified:
By radiation features in horizontal directions: omnidirectional antennas and directional antennas By polarization features: single polarization antennas and dual polarization antennas
Omnidirectional antenna
Page 67
Lightning Arrester
feeder
Lightning Arrester is used to prevent the equipment from being damaged by the lightening current inducted by the core line of the feeder
jumper
Lightning Arrester
Page 68
Cable loss=0.043dB/m
5/4 inch
Cable loss=0.032dB/m
1/2 inch jumper
Cable loss=0.11dB/m Used between the antenna and the main feeder
Page 69
TMA
The tower mounted amplifier (TMA) is a low noise amplification module
installed on the tower top. The TMA is optional. The triplex TMA is usually used and installed close to the antenna. The triplex TMA consists of triplex filter, low noise amplification, and feeder
TMA
Feeder
Receiving filter
Receiving filter
Page 70
Antenna Pattern
The antenna pattern describes the radiating abilities of
360
Omni Antenna
120
90
65
Directional antenna
Page 71
Polarization
Two main types of polarization
Page 73
Configuration Principles
The configuration principles of the BTS3012 cabinet are as follows:
The minimum antenna rule use as few as possible antennas for cell configuration. The minimum cabinet rule use as few as possible cabinets for cell configuration. The complete synchronous cell rule all TRXs of a synchronous cell are configured in the same cabinet group The basic cabinet priority rule TRXs are configured in the basic cabinet in preference, and the number of TRXs in the basic cabinet is not less than that in any extension cabinet
Page 74
Configuration Principles
The BTS3012 supports the omnidirectional coverage and the directional
coverage.
The BTS3012 supports the combination of two cabinets to form one group
function). The DCOM is required when the DTRUs are not sufficient.
The BTS3012 uses DTRU. One single cabinet supports up to 12 TRXs in
full configuration.
The maximum number of carriers is eight in a cell with a pair of dual
RXA1 RXA2 TX A
TX 1
TCOM IN2 TX 2
47.8-1.0
DTRU
Page 76
DDPU
RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 TX B TX A
TX 1 IN 1 TCOM IN2 TX 2
46 or 47.8-1.0
DTRU
Page 77
DDPU
RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 TX B RXB3 RXB4 TX A
TX 1 IN 1 TCOM
IN2 TX 2
DTRU
Page 78
DDPU
RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 TX B RXB3 RXB4 TX A
TX 1 IN 1 TCOM IN2 TX 2
DTRU
DTRU
Page 79
TX 1 IN 1 TCOM IN2 TX 2
TX 1 IN 1 TCOM IN2 TX 2
47.8-3.3-1.0
DTRU
DTRU
Page 80
DDPU
RXA1 TX A RXA2 RXA3 RXA4 RXB1 RXB2 TX B TX B RXB3 RXB4 TX A
DDPU
RXA1 RXA2 RXA3 RXA4 RXB1 RXB2 TX B RXB3 RXB4 TX A
share one DTRU, cell 2 need configure one DTRU and one DDPU.
BSC data configuration
should be DTRU1transmit independence mode receive independence mode DTRU2transmit independence mode receive independence diversity mode
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
TX 1 IN 1 TCOM IN2 TX 2
TX 1 IN 1 TCOM IN2 TX 2
DTRU
RXD 2
DTRU
Page 81
Tx-com
TX1
Tx-com
TX1
TX 2
TX B
RXB3 RXB4
TX 2
DTRU
DTRU
DTRU
DTRU
Page 82
S8/8/8 cell2 is
configured 4 DTRU,2 DCOM and 2 DDPU, cell 2 need cross the cabinet
BSC data configuration
DDPU
RXA1 RXA2 TX A RXA3 RXA4 RXB1 RXB2 TX B RXB3 RXB4
DDPU
Tx-com
TX1
Tx-com
TX1
TX 2
TX 2
TX 1 IN 1 TCOM IN2 TX 2
TX 1 IN 1 TCOM IN2 TX 2
TX 1 IN 1 TCOM IN2 TX 2
TX 1 IN 1 TCOM IN2 TX 2
frequency hopping
DTRU
DTRU
DTRU
DTRU
Page 83
Main
cabinet
cabinet
of main cabinet group
of main
cabinet group
follows: The main and slave cabinets are connected by the data cables, control cables, and clock cables
The main and slave combined cabinets are connected by the clock cables and control cables
The main and slave cabinets and combined cabinets require the DIP switches
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 84
Summary
Functions and features of BTS3012 BTS3012 hardware structure Antenna and feeder system Typical configuration
Page 85
Thank You
www.huawei.com