Professional Documents
Culture Documents
Thames Tideway Tunnel Code of Construction Practice Part B Earl Pumping Station
List of contents
Page number
1 2 3 4 5 6 7 8 9 10 11 12 13
Introduction ...................................................................................................... 1 General requirements ...................................................................................... 2 Communications and community/stakeholder liaison ................................. 2 Site operation ................................................................................................... 2 Public access, highway and river transport .................................................. 3 Noise and vibration .......................................................................................... 4 Air quality.......................................................................................................... 4 Water resources ............................................................................................... 5 Land quality ...................................................................................................... 5 Waste management and resource use ........................................................... 5 Ecology (aquatic and terrestrial) .................................................................... 5 Historic environment ....................................................................................... 6 Other ................................................................................................................. 6
List of figures
Page number
Figure 1.1 Earl Pumping Station: Site context and location plan ................................ 2
ii
1
1.1.1
Introduction
All works described in this document are to be managed and performed to meet the health and safety vision of Zero Incidents, Zero Harm, Zero Compromise for the Thames Tideway Tunnel project (the project). The Code of Construction Practice (CoCP) comprises two parts: a. Part A: General requirements. These measures are applicable project wide. b. Part B: Site-specific requirements. These are site-specific measures where deviations from the general requirements are indicated in Part A.
1.1.2
1.1.3
This document forms the CoCP Part B for the project works at the Earl Pumping Station site and sets out detailed site-specific measures including working hours, site set-up and servicing arrangements, taking into account environmental matters and consultations with the London Borough of Lewisham and other stakeholders. For ease of reference, this document sets out site-specific issues and deviations from Part A; therefore where no site-specific measures are specified, reference should be made to Part A. A plan showing the location of the site is shown in Figure 1.1 overleaf.
1.1.4
1.1.5
Earl Pumping Station Figure 1.1 Earl Pumping Station: Site context and location plan
Note: For detailed limits of land to be acquired or used, refer to the drawings in the Book of Plans.
2
2.1.1
General requirements
As per the CoCP Part A.
3
3.1.1
Site operation
Topic Site-specific requirement The following working hours shall apply to this site: a. standard b. extended. When other types of working hours (CoCP Part A, Table 4.1) are required, these shall be subject to
Working hours
Earl Pumping Station Topic Site-specific requirement consent from the local authority (both the London Boroughs of Southwark and Lewisham) under Section 61 of the Control of Pollution Act 1974. Extended working hours are required at this site to carry out major concrete pours to construct the CSO drop shaft including diaphragm wall panels, base slab, roof slab and other large elements. The contractor shall consult with and provide advance notice to the London Borough of Lewisham regarding the exact timing of any working during extended hours. The London Borough of Southwark shall be notified of any extended working hours at Earl Pumping Station. The site layout shall be arranged to provide for a oneway system for all routine vehicles entering from Yeoman Street and exiting from Croft Street. The hoarding shall incorporate suitable art work on public-facing sections, as defined in CoCP Part A para. 4.3.4a. The standard hoarding shall be 3.6m high around this site. The hoarding on the south boundary shall be reviewed having regard to the progress of development proposals on adjacent land. N/A All concrete used at the site shall be delivered premixed and no concrete batching shall take place onsite.
Site layout
Traffic management
Earl Pumping Station Topic Site-specific requirement Chilton Grove and Croft Street during diversion of the Earl Sewer around the CSO drop shaft. During this phase, vehicles shall exit the site onto Yeoman Street. Revised parking arrangements and necessary suspensions shall be agreed with the London Boroughs of Lewisham and Southwark. Highway layout changes, including removal of trafficcalming features and junction modifications (requiring short-term pedestrian and traffic management), shall be agreed with the London Boroughs of Lewisham and Southwark. Event restrictions shall be agreed in consultation with the London Boroughs of Lewisham and Southwark and Transport for London. N/A The footway diversions on Croft Street, Chilton Grove and Yeoman Street shall be adequately signed and protected.
Event restrictions
Control measures The noise and vibration control measures shall be detailed (and may be modified or added to) in Section 61 consent applications to the local authority. Other
Air quality
Topic Site-specific requirement As per the CoCP Part A. During excavation of contaminated soils, air monitoring for naphthalene shall be carried out. As per the CoCP Part A. N/A
Water resources
Topic Site-specific requirement The contractor shall define and submit pollution control measures to the London Boroughs of Lewisham and Southwark and the Environment Agency for approval prior to dewatering potentially heavily contaminated materials. As per the CoCP Part A. As per the CoCP Part A. All temporary hardstanding (as far as reasonably practicable) on non-foreshore sites shall incorporate permeable surfacing (Sustainable Drainage Systems/flood risk alleviation).
9
Site works
Land quality
Topic Site-specific requirement During excavation of contaminated soils, air monitoring for naphthalene shall be carried out.
Site-specific issues/mitigation The contractor shall discuss land quality assessments and remediation with the London Boroughs of Lewisham and Southwark and obtain their approval in accordance with the contaminated land requirements.
10
11
Earl Pumping Station Topic Site-specific requirement develop any necessary mitigation measures for proposed construction methods. N/A
Other
12
Other
Historic environment
Topic Site-specific requirement As per the CoCP Part A.
13
Other
Other
Topic Site-specific requirement As per the CoCP Part A.
Copyright notice Copyright Thames Water Utilities Limited February 2014. All rights reserved. Any plans, drawings, designs and materials (materials) submitted by Thames Water Utilities Limited (Thames Water) as part of this application for Development Consent to the Planning Inspectorate are protected by copyright. You may only use this material (including making copies of it) in order to (a) inspect those plans, drawings, designs and materials at a more convenient time or place; or (b) to facilitate the exercise of a right to participate in the pre-examination or examination stages of the application which is available under the Planning Act 2008 and related regulations. Use for any other purpose is prohibited and further copies must not be made without the prior written consent of Thames Water. Thames Water Utilities Limited Clearwater Court, Vastern Road, Reading RG1 8DB The Thames Water logo and Thames Tideway Tunnel logo are Thames Water Utilities Limited. All rights reserved.