You are on page 1of 16

1 NOKIA 31/10/2002 RANPAR Version 1.

0
Course Content
Radio Resource Management Overview
Parameter Configuration
Common Channels & Power Control
Load Control
Admission Control
Packet Scheduling
Handover Control
Resource Manager
2 NOKIA 31/10/2002 RANPAR Version 1.0
Course Objectives
At the end of the course you willl be able to:
Describe the difference between controllable and non-controllable loads
Describe the difference between preventive and over overload threshold
Describe the relationships of Load Control with Admission Control and Packet
Scheduler
Name and describe summarily the main RAN parameters related to load control
3 NOKIA 31/10/2002 RANPAR Version 1.0
Load Control
Load Control Functions
Radio Interface Load
BTS Measurements
4 NOKIA 31/10/2002 RANPAR Version 1.0
Load Control Functional Overview
LC is a cell based RRM Function, utilising cell specific:
thresholds set by RNP,
load measurements,
AC, PS & LC algorithms.
Main functions of LC are:
to maximise capacity,
preventive load control,
overload control.
LC performs the function of load control in association with AC & PS
LC Updates load status using resource measurements & estimations provided by AC and
PS
Continuously feeds cell load information to the other RRM functions, e.g. PS and AC
SHO LC in RNC consists of MS specific part and cell specific part. The UE specific part is
the controlling entity between the cell specific entities (LC, AC and PS)
LC
AC AC AC
PS PS PS
RM RM RM
RNC
5 NOKIA 31/10/2002 RANPAR Version 1.0
Load Control Functional Overview
RRM in RNC
LC
AC
PS
Load change
estimations
Load change
estimations
Scheduling period
CCH load
measurement
period
BS
Radio Resource
Indication Period
RL measurement
reporting period
parameters
parameters
measurements
estimations
when changed Load change info
Load status request
Load status
NRT load
measurements
1
2
3
3
6 NOKIA 31/10/2002 RANPAR Version 1.0
LC includes the following load status reports and load control parameters:
Parameters related to the LC, which are common for AC, LC and PS:
PrxTarget [dB], PtxTarget [dBm]
PrxOffset [dB], PtxOffset [dB]
PrxNoise [dBm]
Cell load status, including the load measurement results:
In the Radio Resource Indication Message:
PrxTotal [dBm]
PtxTotal [dBm]
RACH load (# of received RACH preambles during the measurement period)
In the Radio Link Measurement Report:
PtxAverage [dBm]
Estimated cell load:
PrxNc [dBm], PtxNc [dBm] updated by LC
PrxRTinacitive [dBm], PtxRTinacitve [dBm] updated by LC
PrxNRT [dBm], PrxNRT [dBm] updated by PS
Lrt updated by AC
Lnrt updated by PS
Load Control Functional Overview
1
2
3
7 NOKIA 31/10/2002 RANPAR Version 1.0
Load Control
Introduction/Functions
Radio Interface Load
BTS Measurements
8 NOKIA 31/10/2002 RANPAR Version 1.0
Load Estimation Methods
Throughput
based threshold
Wideband power
based threshold
W
i
d
e
b
a
n
d
p
o
w
e
r

l
e
v
e
l
I
t
o
t
a
l
(
c
o
v
e
r
a
g
e
)
Own cell load factor

(capacity)
i=0.5
i=0
i=1
9 NOKIA 31/10/2002 RANPAR Version 1.0
Througput Based Load Estimation
The downlink load of the cell can be estimated by using the sum of the downlink allocated bit
rates as follows
The uplink load of the cell can be estimated by using the sum of the load factors of the users
connected to this cell.
max
1
R
R
N
j
j
DL

=
=

=
+ =
N
j
j UL
load i
1
) 1 (
Max. allowed throughtput of the cell
10 NOKIA 31/10/2002 RANPAR Version 1.0
Power Based Load Estimation- Nokia way
The downlink load of the cell can be estimated by dividing the total downlink transmission
power, P
tx_total
by the maximum Node B transmission power P
tx_BTS,max
.
The uplink load can be estimated with P
rx_noise
, the background and receiver noise and P
rx_total
,
the total received power, according to this formula:
max , _
_
BTS tx
total tx
DL
P
P
=
NR P
P
total rx
noise rx
UL
1
1 1
_
_
= =
11 NOKIA 31/10/2002 RANPAR Version 1.0
Radio Interface Load
The BTS measures the total received power (PrxTotal) and the total transmitted power
(PtxTotal) on cell basis
The BTS reports PrxTotal and PtxTotal of each cell to the RNC by sending RADIO
RESOURCE INDICATION message periodically (RRIndicationPeriod)
LC updates cell load status for each cell based on RADIO RESOURCE INDICATION
LC updates non-controllable UL (PrxNC) and DL (PtxNC) load in cell
AC and PS algorithms work on the current cell load status provided by LC
Denying call admission (AC) and throttling back NRT traffic (PS) are the overload
actions
After scheduling PS provides LC with PrxNRT, PtxNRT & L
NRT
estimates
After admitting RT RAB, AC provides LC with NC load increase estimate
12 NOKIA 31/10/2002 RANPAR Version 1.0
System Noise
System noise (PrxNoise) is the sum of all stationary noises;
thermal noise
interference caused by spurious emissions of other systems,
noise cause by additional equipment such as repeaters
PrxNoise can vary place to place and even time to time
PrxNoise is a RNP parameter whose setting affects the capacity of cell
PrxNoise too low: overestimation of cell load and can lead to unnecessary call blocking
PrxNoise too high: underestimation of cell load and can lead to overload situation
13 NOKIA 31/10/2002 RANPAR Version 1.0
PrxNoise Autotuning Algorithm
RNC provides tools to measure unloaded system noise, PrxUnloaded, and tools to
adjust PrxNoise parameter based on these measurements
PrxTotal = PrxUnloaded when own cell is considered unloaded (or very low load);
Own Cell;
L
RT
Unloaded
RT
and
L
NRT
Unloaded
NRT
Unloaded
RT
and Unloaded
NRT
are RNC parameters (values for NRT: 1 %, RT: 2 %)
L
RT and
L
NRT
are UL load factor for own cell RT (AC estimates) & PS users (PS estimates)
RNC calculates averaged PrxUnloaded values using a mean filter to remove
temporary interference peaks
PrxNoise is updated by the autotuning algorithm based on PrxUnloaded
PrxNoise autotuning step size is limited by PrxNoiseMaxTuneAbsolute parameter
14 NOKIA 31/10/2002 RANPAR Version 1.0
UL Preventive & Overload Thresholds
Prx Target [dB]
PrxTarget [dB] + PrxOffset [dB]
load factor

t
o
t
a
l

r
e
c
e
i
v
e
d
p
o
w
e
r
P
r
x
T
o
t
a
l

[
d
B
m
]
Overloaded Area
Marginal Load Area
Feasible Load Area
15 NOKIA 31/10/2002 RANPAR Version 1.0
UL Preventive Thresholds
Preventive threshold = PrxTarget
Prx Target is relative to the system noise, it gives an upper threshold for the noise rise
Target threshold defines the optimal operating point of the cell load, up to which PS &
AC can operate normally and is calculated from the UL loading () value:
If cell load exceeds these limits then AC & PS move to PREVENTIVE STATE function
New RT RABs are blocked, and PS can't schedule more NRT bit rates in the cell
PrxTarget
range: 0...30 dB, step 0.1 dB
default: 4 dB
( ) [ ] dB Log 1 10
10
PrxTarget =
16 NOKIA 31/10/2002 RANPAR Version 1.0
Overload threshold = PrxTarget + PrxOffset
Overload Threshold defines the limit when the cell is considered to be overloaded
If load in the cell exceeds these limits then AC & PS move to OVERLOAD STATE function
New calls are blocked, and PS starts to decrease NRT bit rates in the cell
PrxOffset
range: 0...6 dB, step 0.1 dB
default: 1 dB
UL Overload Thresholds
17 NOKIA 31/10/2002 RANPAR Version 1.0
DL Preventive & Overload Thresholds
Ptx Target [dBm]
Ptx Target [dBm] + PtxOffset [dB]
load factor

t
o
t
a
l

r
e
c
e
i
v
e
d
p
o
w
e
r
P
t
x
T
o
t
a
l

[
d
B
m
]
Overloaded Area
Marginal Load Area
Feasible Load Area
Cell Maximum
18 NOKIA 31/10/2002 RANPAR Version 1.0
DL Preventive Thresholds
Preventive threshold = PtxTarget
Target threshold defines the optimal operating point of the cell load, up to which PS &
AC can operate normally
If cell load exceeds these limits then AC & PS move to PREVENTIVE STATE function
New RT RABs are blocked, and PS can't schedule more NRT bit rates in the cell
PtxTarget
range: -10...50 dBm, step 0.1 dB
default: 40 dBm
Default value depends on the cell max TX power: in case the cell max power is 43 dBm,
the PtxTarget should be 40 dBm (3 dB below max)
19 NOKIA 31/10/2002 RANPAR Version 1.0
DL Overload Thresholds
Overload threshold = PtxTarget + PtxOffset
Overload Threshold defines the limit when the cell is considered to be overloaded
If load in the cell exceeds these limits then AC & PS move to OVERLOAD STATE function
New calls are blocked, and PS starts to decrease NRT bit rates in the cell
PtxOffset
range: 0...6 dB, step 0.1 dB
default: 1 dB
The default value is given for 20W WPA!
20 NOKIA 31/10/2002 RANPAR Version 1.0
Load Control
Introduction/Functions
Radio Interface Load
BTS Measurements
21 NOKIA 31/10/2002 RANPAR Version 1.0
Prx and Ptx Total Measurements
P
r
x
T
o
t
a
l
/
P
t
x
T
o
t
a
l
Frame average measurements
Frame Prx and Ptx Total
measurements

=
14
0
/ /
Total P Total P
tx rx tx rx
0 14 1 2 ...
22 NOKIA 31/10/2002 RANPAR Version 1.0
Alpha Trimmed Filter
P
r
x
T
o
t
a
l
/
P
t
x
T
o
t
a
l
Ptx/Prx MeasAveWindow
1. Frame average measurement values are sorted
into frames consisting of Ptx/Prx MeasAveWindow
values
2. (Ptx/Ptx MeasAveWindow Ptx/Prx Alpha)
lowest and highest values are removed
3. (Ptx/Ptx MeasAveWindow (1-Ptx/Prx Alpha))
values remain
4. Remaining values are used by the BTS for average
Prx/Ptx Total calculation and are sent to the RNC
every RRIndPeriod
23 NOKIA 31/10/2002 RANPAR Version 1.0
Prx/PtxMeasAveWindow = 10
Prx/PtxAlpha = 0.2
Frame averages are sorted into groups consisting of 10 values
2 lowest and 2 highest values are excluded (0.2 10)
Final P
rx_total
& P
tx_total
averages are calculated using 6 remaining values
( )

+ =
=

=
8
3
_
) 1 (
1
_
6
1
2 1
1
k
k total rx
NoFrames
NoFrames k
k total rx
y P
y
NoFrames
P

( )

+ =
=

=
8
3
_
) 1 (
1
_
6
1
2 1
1
k
k total tx
NoFrames
NoFrames k
k total tx
y P
y
NoFrames
P

Example
Frame average measurements
Prx/Ptx
24 NOKIA 31/10/2002 RANPAR Version 1.0
Parameters
Prx/PtxMeasAveWindow
The parameter defines the number of frames used for long term averaging at the BS of
the short term (frame based) averages of Prx/PtxTotal measurements
range: 10...200 frames, step 1 frame
default: 20 frames (during one RRI period when RRI=200 ms)
In case the measured values are fluctuating very much, the averaging period could be
made longer to get better PS performance
Prx/PtxAlpha
Defines the type of measurement filter used for the total received wideband power
(PrxTotal) in a cell. If the value is 0, pure sliding window mean filter is used and if the
value is 0.5, sliding window median filter is used. If the value is between 0 - 0.5,
trimmed mean filter is used
range: 0... 0.5, step 0.05
default: 0
25 NOKIA 31/10/2002 RANPAR Version 1.0
Radio Resource Indication Period

BTS Measurements
RRI Period
26 NOKIA 31/10/2002 RANPAR Version 1.0
Radio Resource Indication Period
RRIndPeriod
The parameter defines the reporting period of the RADIO RESOURCE INDICATION
messages, which are used for cell based load measurements.
range: 0...2000 ms, step 100 ms
default: 200ms
The BTS informs the RNC about the current load at the radio interface from the radio
resource point of view and the load of every RACH in each cell.
For that purpose the BTS sends periodically a Radio Resource Indication message to the
RNC
In the Radio Resource Indication message the BTS reports periodically:
the total uplink interference power of the cells
the total transmitted power of the cell,
and RACH load
27 NOKIA 31/10/2002 RANPAR Version 1.0
A BTS measures RACH load of cell, and reports it to the RNC using the RADIO
RESOURCE INDICATION message
RACH load includes following measurements:
RACH load: Averaged number of received RACH preambles per radio frame during the
reporting period
RACH decoded messages: Averaged number of all decoded RACH messages per radio frame
during the reporting period
Successfully decoded messages: Averaged number of successfully decoded RACH messages
per radio frame during the reporting period
Reporting is controlled by parameters RRIndicationPeriod & RACHLoadIndicationPeriod
which the BTS receives in the CONFIGURATION DATA message
RACH Measurements
28 NOKIA 31/10/2002 RANPAR Version 1.0
RACHLoadIndicationPeriod
The parameter defines the reporting period of the PRACHs in a BTS. The BTS may
report load figures to the RNC in every Nth (N=1-20) NBAP Radio Resource Indication
message. Value 0 of the parameter means that the BTS does not report the load
information for RACH.
range: 1...20, step 1
default: 1
RACH Measurements
29 NOKIA 31/10/2002 RANPAR Version 1.0
Connection Based Measurements
A base station measures:
transmission power of one carrier
one scrambling code
one channelisation code
and averages it during the reporting period. BTS reports transmitted code powers using dedicate
RADIO LINK MEASUREMENT REPORT message.
Reporting is controlled by RLMeasRepPeriod parameter, which the BTS receives from
the RNC in the CONFIGURATION DATA message.
These measurement reports are used as an input for defining initial power for PS and AC
The report affects the accuracy of PS and AC initial power definition
30 NOKIA 31/10/2002 RANPAR Version 1.0
RLMeasRepPeriod
range: 0...2000 ms, step 100 ms
default: 500 ms
Bigger value decreases I
ub
signalling load, smaller value increases accuracy
Value 0 = OFF
Connection Based Measurements
31 NOKIA 31/10/2002 RANPAR Version 1.0
Chapter 3
-Load Control-

1. Which RRM functional entities are in direct relationship with load control?
2. List the traffic load included in non controllable load
3. List the traffic load included in controllable load
4. Which LC parameter gives the upper limit for the noise rise? What is its default value?
5. What hapens if cell load exceeds this limit?
6. How the overload threshold is defined?
7. What kind of filter is used for WBTS measurements?
8. How offen BTS sends measurement to the RNC?

You might also like