You are on page 1of 2

HSC1200C

1.2-MVA-SOLAR-STATION (Concrete) Container with DC-distribuon, Inverters, Medium-Voltage Transformer and Switchgear
The solar sta on HSC1200C is a new development for large photovoltaic power plants. The concrete container includes the DC-distribu on, the inverter, the medium voltage transformer and the medium voltage switchgear. The HSC1200C is a plug and play solu on for quick installa on with low total costs. The HSC1200C is a completely factory-assembled systemonly the DC-connec ons to the photovoltaic array and the AC-connec on to the medium-voltage grid have to be done on site. The photovoltaic array is linked via fuses or circuit breakers and an EMC-lter to the input of the inverter. As an op on, the current in each string can be measured separately. The inverter system consists of two iden cal inverters. These inverters operate independently and feed their output power into dierent low-voltage windings of a special medium voltage transformer T1 (please refer to the block diagram below), op mized for the photovoltaic array. The container is connected to the grid via the internal medium-voltage switchgear. Op onally, the auxiliaries of the inverter system and the hea ng can be fed by transformer T2 or from an external source. Each inverter is supplied with all necessary control systems and has its own maximum-power-point tracker. As standard, a PC-based monitoring system with an Ethernet interface provides all important informa on to the user. In the unlikely case of malfunc on, a failure message is generated and sent automa cally. Op onally the communica on can be realized via GSM modem.

Block diagram HSC1200C

Helios Systems Wind&Sun Technologies Company Inverters made by FeCon GmbH www.helios-systems.net Tel.: 0049 461 430 122-0 Fax: 0049 461 430 122-11 E-Mail: info@fe-con.com

Technical Data Version 1.8

Technical Data HSC1200C


Electrical Data Rated AC-power at 10 % of rated grid voltage Rated apparent power Rated grid voltage (other voltage levels and frequencies on request) Short circuit level Maximum AC-current Line power factor (cos ) at 20 % rated power AC-current distor on (THD) at rated power Rated PV-power within 10 % of rated grid voltage Maximum PV-power at rated grid voltage Maximum PV-current Maximum PV no-load-voltage MPP-area at rated PV-power Control strategy Eciency at (10|30|50|75|100) % power EU eciency incl. transf. losses / inductor and auxiliary losses EU eciency incl. transf. losses / inductor, excl. auxiliary losses EU eciency excl. auxiliary losses Feed-in star ng at Standby losses / at night Maximum auxiliary power General Data Ambient temperature (others on request) Rela ve humidity non-condensing Maximum al tude without dera ng in power Cooling type Minimum air quality acc. to EN 60721-3-3 Protec on class Dimensions H x W x D Weight Container surface Colour of cabinet / colour of container Approvals and cer cates -10 C to 45 C 1500 m above sea level Forced air cooling Class 3S2 IP54 3200 mm x 7380 mm x 2680 mm < 38,000 kg Concrete BDEW-MSRL / FGW / TR8; EN 61000-6-2; EN 61000-6-4; EN 61000-3-12; EN 61000-3-11; EN 50178; Guida Enel 1000 kW 1210 kVA 20 kV, 3~, 50 Hz/60 Hz 34.9 A > 0.98 at rated power <3% 1028 kW 1140 kW 2460 A 1000 V= 450 V= to 880 V= MPP-Tracking (96.3|97.6|97.7|97.3|97.1) % 97.1 % 97.3 % 1400 W 80 W control power + 1100 W transformer loss < 3000 W + hea ng power (if necessary)

Features DC-disconnec on AC-disconnec on Display Earth leakage detec on Surge arresters LVRT-Handling. Communica on Cabinet Opons Display within control cabinet for display of status Separately fused DC-inputs Earthing of solar eld (posi ve or nega ve is grounded) Measuring and monitoring of single input currents Hea ng External heat exchanger for very dusty/moist ambients and extreme clima c condions. Dehumidiers in converter room MV-switchgear with vacuum circuit breaker or fuses for transformer Change of 20 kV medium voltage design to other voltages Incl. thermostat DC-disconnector Grid contactor Industry PC with monitor Earth leakage monitor With monitoring on AC- and DC-side Incl. Standard

Helios Systems Wind&Sun Technologies Company Inverters made by FeCon GmbH www.helios-systems.net Tel.: 0049 461 430 122-0 Fax: 0049 461 430 122-11 E-Mail: info@fe-con.com

You might also like