You are on page 1of 9

TS

SUMMARY

REF. : 36827ter

1. OPTICAL FIBRE CABLES All dielectric self supported cable for aerial installation
Loose tube cables (flat FRP armoured) 24 G652D single mode fibres Particular sheet of the cable

2. PARTICULAR SHEET FOR OPTICAL FIBRE


Particular sheet of the optical fibre G 652D

3. IDENTIFICATION

4. DELIVERY CONDITIONS

5. TABLE OF TEST

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS

REF. : 36827ter

1. ALL DIELECTRIC SELF-SUPPORTING OPTICAL FIBRE CABLES WITH 24 O.F. FOR SPAN UP TO 330 METERS
1. Colour-coded optical fibres (up to 12 OF/tube) 2. Filling compound. 3. Colour-coded thermoplastic tubes (containing up to 12 optical fibres) or fillers (replacing tubes without fibres). 4. Central high-modulus dielectric strength member + optional coating. 5. Longitudinal watertightness (standard: "clean cables" using swellable materials/elements) 6. Binders + optional tape. 7. Aramid yarns 8. PE inner jacket. 9. Rigid dielectric armour constituted of stranded flat GRP elements. 10. Aramid yarns 11. HDPE outer jacket (standard colour: black)./ Optional : anti-tracking oversheathing. (a) (a) an additional outer anti-tracking sheath is recommended if the cable is installed near (< 2.0 m) an extra-high voltage conductor

Cable diameter Cable weight

: 18 mm : 280 kg/km

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS
CABLE DATA SHEET

REF. : 36827ter

1. ALL DIELECTRIC SELF-SUPPORTING OPTICAL FIBRE CABLE WITH 24 O.F. FOR SPAN UP TO 330 METERS
CHARACTERISTICS
Fibre-Count CONSTITUTION
Cable design Central strength member Filling compound Tube dimensions Strength members around the assembly Inner sheath Armouring (strength members) des renforts de tractions Outer sheath (a) Outer sheath thickness Cable diameter Cable weight 2 watertight tubes containing 12 optical fibres + 4 fillers non metallic (FRP) synthetic 1.6/2.5 Aramid yarns Polyethylene Stranded flat FRP elements + aramid yarns HD polyethylene 2.0 18 280 235* 225*

UNIT

SPECIFICATION
24

mm

mm mm kg/km mm mm

BENDING RADIUS

(IEC & EN 60794-1-2 E10 & E11)

Minimum bending radius Minimum kinking radius

TENSILE PERFORMANCE

(IEC & EN 60794-1-2 E1)

Installation in ducts & direct burial Maximum tensile force during installation (short term) Maximum permanent tensile force Aerial installation Tensile force during operation

daN daN

3400 * 1350* see next page

CRUSH PERFORMANCE (IEC & EN 60794-1-2 E3)


Maximum strain daN/cm
(IEC & EN 60794-1-2 E4)

40* 20 (R = 300 mm,3 impacts) (no fibre break) -40C/+70C ( < 0.1 dB/km @ 1550 nm)* -5C/+40C Compliant to IEC 60794-1-2-F5 (3m/24h) Yes with standard european rats (Rattus Norvegicus and Long Evans Rattus) yes

IMPACT TEST
Energy

N.m

TEMPERATURE RANGE
- Operating/Storage - Installation

WATERTIGHTNESS RODENT RESISTANCE SHOT GUN RESISTANCE PACKING

m 4100 Delivery length, m G export + battens. Drum type m 1.9 x 1.15 Drum size kg 1620 Weight of the loaded drum * : reversible after test (a) an additional outer anti-tracking sheath (thickness ~0.5 mm) is recommended if the cable is installed near (< 1.5 m) an extra-high voltage conductor

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS

REF. : 36827ter

1. ALL DIELECTRIC SELF-SUPPORTING OPTICAL FIBRE CABLE WITH 24 O.F. FOR SPAN UP TO 330 METERS
24 OF Cable MAIN CHARACTERISTICS FOR AERIAL INSTALLATION 2 Cable Young modulus : 1663 daN/mm Cable temperature expansion coefficient : 1.20.10-5/C Cable breaking tensile load : 6805daN Cable elastic limit : 2265daN

CLIMATIC CONDITIONS FOR AERIAL INSTALLATION


Maximum span : 330 m (initial sag @ +15 C = 2.5 % of span) Conditions Installation Winter 1 Winter 2 Average Temperature, C 15 -40 -40 5 Wind ~550 (55 ~550 (55 Pa 0 0 daN/m2) daN/m2) pressure or m/s 0 0 28.58 28.58 speed km/h 0 0 102.89 102.89 thickness, mm 0 5 0 0 Ice / frost kg/m 0 0.29 0 0 Tensile, daN 462 738 1224 1160 Sag, m 8.25 9.24 11.44 12.07 Maximum span : 330 m (initial sag @ +15 C = 3.0 % of span) Conditions Installation Winter 1 Winter 2 Average Temperature, C 15 -40 -40 5 Wind ~550 (55 ~550 (55 Pa 0 0 daN/m2) daN/m2) pressure or m/s 0 0 28.58 28.58 speed km/h 0 0 102.89 102.89 thickness, mm 0 5 0 0 Ice / frost kg/m 0 0.29 0 0 Tensile, daN 385 732 1117 1064 Sag, m 9.90 10.58 12.54 13.17 Maximum span : 330 m (initial sag @ +15 C = 3.5 % of span) Conditions Installation Winter 1 Winter 2 Average Temperature, C 15 -40 -40 5 Wind ~550 (55 ~550 (55 Pa 0 0 2 2 daN/m ) daN/m ) pressure or m/s 0 0 28.58 28.58 speed km/h 0 0 102.89 102.89 thickness, mm 0 5 0 0 Ice / frost kg/m 0 0.29 0 0 Tensile, daN 330 646 1021 978 Sag, m 11.55 11.99 13.72 14.32

Summer 1 Summer 2 35 35 ~550 (55 0


daN/m2)

0 0 0 0 439 8.67

28.6 103 0 0 1122 12.48

Summer 1 Summer 2 35 35 ~550 (55 0


daN/m2)

0 0 0 0 370 10.30

28.6 103 0 0 1032 13.58

Summer 1 Summer 2 35 35 ~550 (55 0


daN/m2)

0 0 0 0 320 11.92

28.6 103 0 0 951 14.72

Note: This cable can be also installed with a sag of 2 % of span (sag = 6.60 m / installation tensile force @ +15 C = 580 daN).
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS
2. PARTICULAR SHEET FOR OPTICAL FIBRE

REF. : 36827ter

REDUCED-WATER-PEAK SINGLE MODE OPTICAL FIBRE (G652D) NOMENCLATURE


TECHNOLOGY GEOMETRICAL CHARACTERISTICS - wavelength - mode field diameter - cladding diameter - coating diameter - cladding non circularity - coating/cladding concentricity error - core/cladding concentricity error TRANSMISSION CHARACTERISTICS - cabled cut-off wavelength - attenuation at 1310 nm (1), at 1383 nm, at 1550 nm (1), at 1625 nm - transmission curve regularity at 1550 nm - chromatic dispersion between 1285-1330 nm - chromatic dispersion at 1550 nm - PMD (value for fibre in cable) STANDARD nm m m m % m m

UNIT

SPECIFICATION
Coating EPOXY - ACRYLATE 1310 9.1 + 0.5 125 + 1 245 + 10 <1 < 10 < 0.6 cc < 1260 < 0.36 (1) < 0.35 < 0.22 (1) < 0.26 < 0.1 < 3.5 < 18 < 0.2 ITU-T Recommendation G652 D

nm dB/km dB/km dB/km dB/km dB ps/nm.km ps/nm.km ps/km 1/2

(1) : 10 % of the fibres (in cable) presented in reception can have an attenuation : < 0.38 dB/km at 1310 nm < 0.23 dB/km at 1550 nm

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS

REF. : 36827ter

3. IDENTIFICATION

1. MARKING. Hot foil marking every meter on cable outer sheath. We propose the following marking " Week Year number of fibre OF SM G652D SILEC " + metric marking Metric marking will be expressed in meters.

2 .IDENTIFICATION. Colour-coding of tube and fibres in each tube : Fibre colour code : red, blue, green, yellow, violet, white , orange , grey, brown, black, aquamarine, pink. Tube colour code red, blue.

3. DRUM IDENTIFICATION The following information are included on a plate or label fixed on the drum: - Cable description, - Cable code, - Length and weight of drum, - Drum number, - Order number, - Year of manufacture, - SILEC CABLE

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS
4. DELIVERY CONDITIONS

REF. : 36827ter

1. CABLE LENGTHS.
Standard delivery lengths: L 3 % (value of L: refer to cable particular sheet) Provisions for irregular lengths: - up to 10% of the total order length (with a minimum of one L length) may be split in two equal L/2 lengths - up to 10% of the total order length (with a minimum of one length) may be delivered in irregular lengths

2. SEALING OF ENDS.
Each cable end is sealed with an heat-shrinkable cap.

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS
5. TABLE OF TESTS
1 / ROUTINE TESTS
We propose routine tests according to the following table.

REF. : 36827ter

1/2

Sampling Tests Dimensional


- outer diameter - thickness of the sheath - identification Optical and transmission - attenuation (1) in the specified window(s) - regularity of attenuation at 1550 nm(SM) or 850 nm(MM) Mechanical on the outer sheath - tensile strength - elongation at break Environment - water penetration (2)

Reference
IEC 60811-1-1

SILEC CABLE
1 cable (a) " "

Acceptance (*)
1 cable " "

IEC 60793-1-40-C back-scattering Method

100 % 100 %

10 % of cable (10 % of OF) "

IEC 60811-1EN 50290-2-24 (PE)

1 cable (b) "

1 cable "

IEC 60794.1.2-F5B 1 cable (c) 1 cable

(*) Acceptance test program to be agreed between customer and SILEC at the time of ordering.

Nota :
(a) : 1 test/design of cable / week (b) :1 test per period/ type of outer sheath/ manufacture line Period = 1 month if PE sheath (c) : 1 test/design of cable /month (1) attenuation : Backscattering measurements performed from one cable end (1.55 m for SM OF / 0.85/1.3 m for MM OF) + optical continuity for all fibres. In case of limit values, the measurement will perform from both ends and the attenuation is the average of the both values. In case of doubt, the attenuation will be determined by the cut-back reference method (IEC 60793-1-40-A). Attenuation value is significant only for cable length 1 km For cable length < 1km, only the regularity of transmission at 1550 nm (SM) or 850 nm (MM) will be controlled.

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.

TS
5. TABLE OF TESTS
(Following)

REF. : 36827ter

2/2

(2) Water penetration test Applicable to the whole cable or only to watertight parts, according to cable design and specifications. Conditions : sample length : 3 meters; water height: 1 m; duration: 24 hours

2 / TYPE TESTS (not included in cables price) :


We perform ISO 9001 certified Quality Assurance system and internal test procedures ensuring that the cables supplied meet the requirements of customer. In this framework, type tests are carried out when initially designing/developing the given cable type, and are not intended to be repeated on every order or manufactured cable length. However, on customer's request, the renewal of some type tests may be considered as part of the order acceptance program, providing an agreement has been reached between the customer and SILEC at the time of ordering, including, if any, the specific conditions applicable to the implementation of the tests. Alternatively, certificates of conformity or test reports, relating to previous supplies and/or qualification programs of same or similar cable type, can be provided as part of the technical documentation pertaining to the order.

For information, the following table shows the main type tests relevant to the proposed type of cable and supporting the characteristics stated in the cable particular data sheet. Reference IEC 60794.1.2EN 60794.1.2 E1 E3 E4 E10 E11 F1

- tensile resistance - crush resistance - impact resistance - kink resistance - bending resistance - temperature cycling

Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.