DESIGN OF RIBBED OR WAFFLE SLAB GIVEN DATA Width of topping Thickness of rib 1.2 m 100 m 3.9 m 3.

6 m 150 mm 25 mm 10 kN/m2 25 N/mm2 415 N/mm2 20 mm 1200mm 3900 3600

b Ly Lx

Thickness of topping Topping-allowed for funicular shells Assume udl

w fck fy

cover thickness CHECK DIMENSION FOR CODE REQUIREMENTS STEP 1 IS456-2000 CLAUSE 30.5 Rib width Rib spacing Topping 25mm allowed for funicluar shells Depth The slab can be designed as two-way slab CALCULATE DESIGN MOMENTS STEP 2 Ly / LX Hence it can be designed as two-way slab IS 456-2000 TABLE-26 Two adjacent sides are continuous (case -4) 100m 1.2m

>65m <1.5m 130 mm

1.083333333 m

Coefficient Negative Positive

short span x long spany 0.052 0.047 0.039 0.035

Assume same rib in x and y directions Maximum negative moment Maximum positive moment Maximum moment one rib has to carry= moment per metre x rib spacing Maximum negative B.M Maximum positive B.M STEP 3 CALCULATION OF AREA 8.08704 kNm/m 6.06528 kNm/m 6.7392 kNm/m 5.0544 kNm/m

Assume under reinforced section

Mu = 0.87 * fy * Ast *(d-0.42*xu)


FOR SUPPORT SECTION:

Mu = 0.87 * fy * Ast *(d-0.42*(0.87*fy*Ast/0.36*fck*b))