The network maintenance is based on the supervision of the network, by using the OAM graphical
interface. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide
(NN-20500-032).
The network maintenance is based on the supervision of the network, by using the OAM graphical
interface. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide
(NN-20500-032).
The network maintenance is based on the supervision of the network, by using the OAM graphical
interface. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide
(NN-20500-032).
W-CDMA Alcatel-Lucent 9326 digital 2U Node B Maintenance Guide NN-20500-110 03.03/EN Standard May 2009 Wireless Service Provider Solutions W-CDMA Alcatel-Lucent 9326 digital 2U Node B Maintenance Guide Document number: NN-20500-110 Document issue: 03.03/EN Document status: Standard Product release: UA06.0 Date: May 2009 Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction Copyright 2007-2009 Alcatel-Lucent, All Rights Reserved UNCONTROLLED COPY: The master of this document is stored on an electronic database and is "write protected"; it may be altered only by authorized persons. While copies may be printed, it is not recommended. Viewing of the master electronically ensures access to the current issue. Any hardcopies taken must be regarded as uncontrolled copies. ALCATEL-LUCENT CONFIDENTIAL: The information contained in this document is the property of Alcatel-Lucent. Except as expressly authorized in writing by Alcatel-Lucent, the holder shall keep all information contained herein confidential, shall disclose the information only to its employees with a need to know, and shall protect the information from disclosure and dissemination to third parties. Except as expressly authorized in writing by Alcatel-Lucent, the holder is granted no rights to use the information contained herein. If you have received this document in error, please notify the sender and destroy it immediately. Alcatel-Lucent, Alcatel, Lucent Technologies and their respective logos are trademarks and service marks of Alcatel-Lucent, Alcatel and Lucent Technologies. All other trademarks are the property of their owners. PUBLICATION HISTORY SYSTEM RELEASE: UA06.0 May 2009 Issue 03.03/EN Preliminary Update for DR5 November 2008 Issue 03.02/EN Preliminary Update after internal review July 2008 Issue 03.01/EN Preliminary Editorial update for UA06.0 SYSTEM RELEASE: UA05.1 April 2008 Issue 02.01/EN Standard Update for UA05.1.2 SYSTEM RELEASE: UA05.0 September 2007 Issue 01.03/EN Standard Update for UA05.0 Channel Readiness SYSTEM RELEASE: UA04.2.7 May 2007 Issue 01.02/EN Preliminary Update after internal review April 2007 Issue 01.01/EN Draft Publication history 3 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide Creation for UA04.2.7 T Publication history 4 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 1 About this publication................................................................................................................................................... 7 2 Access Network Roadmap............................................................................................................................................ 9 3 New in this release....................................................................................................................................................... 10 4 Corrective maintenance activity................................................................................................................................. 11 5 9326 d2U introduction..................................................................................................................................................14 6 9326 d2U hardware presentation................................................................................................................................ 16 7 9326 d2U power up and power down procedures.....................................................................................................18 7.1 Powering up a 9326 d2U......................................................................................................................................... 19 7.2 Powering down a 9326 d2U.....................................................................................................................................20 8 9326 d2U corrective maintenance procedures..........................................................................................................21 8.1 Replacing the digital shelf equipment....................................................................................................................... 22 8.1.1 Replacing the iCEM-U........................................................................................................................................ 23 8.1.2 Replacing the iCCM-U........................................................................................................................................26 8.1.3 Replacing an optical transceiver........................................................................................................................ 31 8.1.4 Replacing the pre-cabled 9326 d2U rack........................................................................................................... 34 8.2 Replacing the optional equipment............................................................................................................................ 43 8.2.1 Replacing the External Alarm module................................................................................................................ 44 8.2.2 Replacing the LPPCM module........................................................................................................................... 46 Table of contents 5 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide Figure 1 - Outside view of the 9326 d2U............................................................................................................ ......... 15 Figure 2 - 9326 d2U pyramidal view (without shielded faceplate)......................................................... ............. ......... 16 Figure 3 - 9326 d2U front view.............................................................................................................. ............. ......... 17 Figure 4 - Location of modules in the 9326 d2U................................................................................... ............. ......... 17 Figure 5 - iCEM-U front panel............................................................................................................... ............. ......... 23 Figure 6 - iCCM-U front panel............................................................................................................... ............. ......... 27 Figure 7 - Location of optical connectors in the 9326 d2U.................................................................... ............. ......... 32 Figure 8 - Inserting an SFP transceiver in the iCCM-U......................................................................... ............. ......... 32 Figure 9 - 9326 d2U front view.............................................................................................................. ............. ......... 35 Figure 10 - Front panel of the External Alarm module.......................................................................... ............. ......... 44 Figure 11 - LPPCM module front panel................................................................................................. ............. ......... 46 List of figures 6 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 1 About this publication This publication describes the corrective maintenance procedures applicable to the 9326 d2U rack. Note: This publication only describes maintenance procedures relating to 9326 d2U V1 product. For detailed information on 9326 d2U V2 maintenance, refer to the following document: Alcatel-Lucent 9326 digital 2U Node B V2 - Maintenance Guide (NN-20500-204). Applicability This publication applies to UA06.0. Audience The publication is intended for operation and maintenance personnel and for those who want to know the principles of 9326 d2U maintenance. Prerequisites It is recommended that readers become familiar with the following publications: Alcatel-Lucent 9326 digital 2U Node B - Technical Description (NN-20500-108) Alcatel-Lucent 9300 W-CDMA Product Family documentation: Terminology (NN-20500-002) Node B Alarms Reference Guide (NN-20500-018) Alcatel-Lucent Node B - Commissioning & Fault Management User Manual: TIL (NN-20500-019) How this publication is organized This publication consists of eight parts: The first chapter lists what is new in this publication. The second part describes the corrective maintenance activity. The third part introduces the 9326 d2U rack. The fourth part presents the 9326 d2U hardware. The fifth part describes the pre-requisite procedure. The sixth part describes the power up and power down procedures. The last part describes the corrective maintenance procedures. Vocabulary conventions For a list of terms used in this publication, see Alcatel-Lucent 9300 W-CDMA Product Family - Terminology (NN-20500-002). 7 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide Safety regulation In order to guarantee the safety of personnel and equipment the following aspects must be taken into account: general personnel safety instructions equipment safety instructions Caution, warning, and danger messages indicate the following possible risks. CAUTION Impact on service and on the equipment DANGER Electric shock DANGER Environment and personnel protection CAUTION ElectroStatic Discharge Sensitive (ESDS) handling precautions 8 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 2 Access Network Roadmap For collection roadmap, see Alcatel-Lucent 9300 W-CDMA Product Family - Document Collection Overview and Update Summary (NN-20500-050). 9 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 3 New in this release The following sections detail what is new in Alcatel-Lucent 9326 digital 2U Node B - Maintenance Guide for UA06.0. Features None Other changes Review comments added 10 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 4 Corrective maintenance activity This part describes the corrective maintenance activity applicable to the 9326 d2U rack. Corrective maintenance The network maintenance is based on the supervision of the network, by using the OAM graphical interface. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032). It is also based on the identification and replacement of faulty items of equipment, using the alarms. The process is divided into the following two steps: locating and identifying the faulty items of equipment, by using the information provided in Alcatel-Lucent 9300 W-CDMA Product Family - Node B Alarms Reference Guide (NN-20500-018). replacing the faulty items of equipment, by using the replacement procedures given in this document. Replacing the digital shelf equipment Procedure Product Engineering Code (PEC) Common Product Code (CPC) Impact on service Replacing the iCEM-U NTUM36AA N0099941 Loss of capacity or loss of service (depending on the number of iCEM-U in the digital shelf) Replacing the iCCM-U NTUM36MA N0099944 Loss of service on the Remote Radio device(s) associated with the iCCM-U be- ing replaced Replacing an optical transceiver Single-Mode (SM): NTU850HA Single-Mode (SM): N0146844 Loss of service on the Remote Radio device associated with the optical trans- ceiver being replaced Multi-Mode (MM): NTU850HM Multi-Mode (MM): N0146845 Replacing the pre- cabled 9326 d2U rack NTU808AA N0143700 Service interruption 11 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide Replacing the optional equipment Procedure Product Engineering Code (PEC) Common Product Code (CPC) Impact on service Replacing the LPPCM module NTU870GM N0146847 None Replacing the External Alarm module NTU870GA N0146846 None Description of a replacement procedure A replacement procedure is divided into the following parts: the title the main body with the following information: the intervention time the tools required the impact of the procedure, if necessary the step-by-step actions of the procedure One or more figures are provided to help you execute the actions. They show the FRU schematically and its location in the cabinet. Intervention restrictions There may be a lapse of time between the identification of the alarm at the Access OAM Graphic User Interface (GUI) and the time you arrive at the site. You must be synchronized with the access network controller or system administrator (by telephone) before an on-site intervention, in the following cases: isolating procedures completion of an on-site intervention return to service procedure General personnel safety instructions The personnel must obey the safety instructions specific to the installation site: rules concerning the premises (see instructions posted on site or in the building) rules linked to general personnel safety instructions The personnel working on the cabinet must be authorized to work according to security standards. 12 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent Equipment safety instructions The 9326 d2U normally operates when the external temperature is between -5C and +65C. 13 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 5 9326 d2U introduction The 9326 d2U is a digital rack designed to be connected to one of the following products via optical fiber links: 9341 RRH20-21 9341 RRH40 9332 rCompact OD The Alcatel-Lucent Remote Radio solution improves flexibility for deploying mobile broadband Node Bs in space-constrained locations. It is particularly suited to macro-cellular application in dense areas, where site acquisition is difficult, and on sites where installation constraints prevent the use of legacy Node Bs. Compared to legacy Node B site deployment, the Remote Radio solution provides the following benefits: reduced volume, weight, footprint, acoustic noise, and power consumption reduced cost of feeder paths from the Node B to the antenna increased RF power per carrier at the antenna feeder reduced radio loss with use of the remote RF block concept, which eliminates the distance between the radio amplifier and the antenna The Remote Radio solution provides for the UMTS system: the means of communication between a User Equipment (UE) and a network using Transport Channels physical layer channels, which are necessary to synchronize the downlink and perform cell selection/reselection and handover preparation measurement information to the UMTS RNC for radio resource management (handover, power control) The 9326 d2U provides up to eight E1/T1 with Inversion Multiplexing ATM (IMA) or Drop-and-Insert capability (fractional E1/T1). The 9326 d2U also supports multi-PCM without IMA. The 9326 d2U delivers high UMTS radio performances and supports the enhanced High Speed Downlink Packet Access (HSDPA) and High Speed Uplink Packet Access (HSUPA) solutions through easy software upgrade. The Alcatel-Lucent 9326 d2U solution is compliant with the Common Protocol Radio Interface (CPRI). 14 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 9326 d2U enclosure The 9326 d2U provides the operators with a suited solution whatever the site constraints are. The 9326 d2U can be installed in a standalone indoor mode or in the user space of an existing indoor or outdoor Node B cabinet. The 9326 d2U is factory-equipped with a specific shielded faceplate. The following figure shows an outside view of the 9326 d2U. Figure 1 Outside view of the 9326 d2U 15 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 6 9326 d2U hardware presentation The 9326 d2U is built around the following components: a mechanical enclosure (including two fans), compatible with standard 19-inch rack installation a digital shelf including the digital modules and the associated digital backplane a commissioning module located on the right hand side of the digital shelf a shielded faceplate The following figure shows a pyramidal view of the 9326 d2U (without shielded faceplate). Figure 2 9326 d2U pyramidal view (without shielded faceplate) The following figure shows the front view of the 9326 d2U. 16 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent Figure 3 9326 d2U front view The following figure shows the location of modules in the 9326 d2U (without shielded faceplate). Figure 4 Location of modules in the 9326 d2U 17 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 7 9326 d2U power up and power down procedures This part describes how to power up and power down the 9326 d2U rack. 18 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 7.1 Powering up a 9326 d2U Perform the following procedure to power up a 9326 d2U. Initial check On the RUC module, check that the power switch is in the "O" position. Procedure Step Action 1. At the operator DC power supply, put the site circuit breaker of the 9326 d2U in the "ON" position. 2. On the RUC module, put the power switch in the "I" position. 3. Check that the fans are starting up. 4. On the iCCM-U and on each iCEM-U, check that: the green LED is ON. the red LED is OFF. --End-- 19 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 7.2 Powering down a 9326 d2U Perform the following procedure to power down a 9326 d2U. Procedure Step Action 1. Preliminary operation: make sure that the btsSiteManager object is "locked". 2. On the RUC module, put the power switch in the "O" position. 3. Check that the green or red LED on the iCCM-U and on each iCEM-U is OFF. 4. Check that the fans are stopping down. 5. At the operator DC power supply, put the site circuit breaker of the 9326 d2U in the "OFF" position. --End-- 20 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 8 9326 d2U corrective maintenance procedures This part contains the replacement procedures applicable to the 9326 d2U rack. 21 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 8.1 Replacing the digital shelf equipment This part presents the replacement procedures applicable to the digital shelf. Those replacement procedures concern the following modules: integrated Channel Element Module-U (iCEM-U) integrated Core Control Module-U (iCCM-U) optical transceiver 9326 d2U pre-cabled rack 22 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 8.1.1 Replacing the iCEM-U Carry out the following procedure to replace an iCEM-U. Intervention time Ten minutes Tools required Screwdriver Extraction tool CAUTION ESDS handling precautions Wear the antistatic bracelet when performing the maintenance procedure described below. WARNING Service interruption This procedure causes a loss of capacity or a loss of service (depending on the number of iCEMs-U in the digital shelf). Figure 5 iCEM-U front panel 23 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide Procedure Step Action 1. Open the door(s) of the Node B. 2. Locate the faulty iCEM-U in the digital shelf: its red triangular LED is ON. 3. Lock the faulty cem object at the OMC by Set Administrative State. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032). 4. Untighten the eight screws from the shielded faceplate, as shown below. 5. Remove the 9326 d2U shielded faceplate, handling with care the associated gasket. 6. Remove the defective iCEM-U using the extraction tool. 24 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 7. Check the release of the new iCEM-U. 8. Insert the new iCEM-U into the digital shelf. 9. Check the state of the LEDs. They should go on, then take the following state: red triangular LED OFF and green rectangular LED ON 10. Put in place the shielded faceplate, taking care not to damage the associated gasket. 11. Tighten the eight screws on the shielded faceplate. 12. Close the door(s) of the Node B. --End-- 25 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 8.1.2 Replacing the iCCM-U Carry out the following procedure to replace the iCCM-U. Intervention time 20 minutes Tools required Screwdriver Extraction tool CAUTION Laser Class 1 hazards - laser emission During the iCCM-U replacement procedure, never expose the eyes to laser emission of optical transceivers. Never look at the optical cable ferrule since the Remote Radio device is the master for opening the optical communication with the 9326 d2U. This means that the Remote Radio device will transmit a laser signal, even if the optical fiber is disconnected on the 9326 d2U side. CAUTION ESDS handling precautions Wear the antistatic bracelet when performing the maintenance procedure described below. WARNING Service interruption This procedure requires a service interruption from the Node B. 26 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent Figure 6 iCCM-U front panel Procedure Step Action 1. Open the door(s) of the Node B. 2. CAUTION Service interruption There will be a loss of service on the Remote Radio device(s) associated with the iCCM-U being replaced. Lock all the objects associated with the Remote Radio devices connected to the faulty iCCM-U at the OMC by Set Administrative State. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032). 3. Power down the 9326 d2U. To do this, follow the procedure Powering down a 9326 d2U. 27 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 4. Untighten the eight screws from the shielded faceplate, as shown below. 5. Remove the 9326 d2U shielded faceplate, handling with care the associated gasket. 6. Unplug the iCCM-U from its RBP connectors using the extraction tool. 7. Disconnect the optical fiber(s) from the iCCM-U front panel. 8. Remove the SFP transceiver(s) from the iCCM-U front panel. 9. Disconnect the digital cable (connector labeled "ALARM" on the shielded faceplate) from the iCCM-U front panel. 10. Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel. 11. Extract the defective iCCM-U using the extraction tool. 12. Insert the new iCCM-U into the slot guides without plugging it on the RBP. 28 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 13. Reinsert the SFP transceiver(s) through the iCCM-U front panel. 14. CAUTION Sense for Multi-Mode LC connectors In case of an iCCM-U equipped with MM SFP transceivers, when reconnecting the optical fibers on the iCCM-U front panel, put the LC connectors (L/R) in the same sense as they were before the intervention. Reconnect the optical fiber(s) on the iCCM-U front panel. 15. Reconnect the digital cable on the iCCM-U front panel. 16. Insert completely the new iCCM-U into the digital shelf by plugging it into its RBP connectors. 29 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 17. Put in place the shielded faceplate, taking care not to damage the associated gasket. 18. Tighten the eight screws on the shielded faceplate. 19. Power up the 9326 d2U. To do this, follow the procedure Powering up a 9326 d2U. 20. Check the state of the iCEM-U/iCCM-U corporate LEDs. They should turn on, then take the following state: red triangular LED OFF and green rectangular LED ON. 21. Reconnect the E1/T1 connector (PCM link) on the iCCM-U front panel. 22. Unlock from the OMC the objects previously locked through step 2. 23. Check the state of the LEDs and display: the iCEM-U/iCCM-U corporate LEDs should have the following state: red triangular LED OFF and green rectangular LED ON. the green PCM LEDs should be ON. the display should indicate the PCM synchronization. 24. Close the door(s) of the Node B. --End-- 30 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 8.1.3 Replacing an optical transceiver Carry out the following procedure to replace a defective optical transceiver. Intervention time Five minutes Tools required None CAUTION Laser Class 1 hazards - laser emission During this replacement procedure, never expose your eyes to laser emission of optical transceiver. Never look at the optical cable ferrule since the Remote Radio device is the master for opening the optical communication with the 9326 d2U. This means that the Remote Radio device will transmit a laser signal, even if the optical fiber is disconnected on the 9326 d2U side. CAUTION ESDS handling precautions Wear the antistatic bracelet when performing the maintenance procedure described below. Procedure Step Action 1. Open the door(s) of the Node B. 2. Locate the faulty SFP transceiver: its two green RX/TX OPTIC LEDs (close to the eight PCM LEDs) are OFF. 31 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide Figure 7 Location of optical connectors in the 9326 d2U 3. At the OMC, through Set Administrative State, lock the FDDCell object associated with the Remote Radio device connected to the optical transceiver being replaced. 4. Disconnect the optical fiber connected to the defective SFP transceiver (optical output labeled "OPTIC1", "OPTIC2" or "OPTIC3"). 5. Extract with care the defective SFP transceiver. 6. Check that the new replacing SFP transceiver has the same type as the SFP transceiver being replaced. Be sure to replace a SM SFP transceiver with a SM SFP transceiver and a MM SFP transceiver with a MM SFP transceiver. 7. Put in place the new SFP transceiver and insert it in the iCCM-U. Figure 8 Inserting an SFP transceiver in the iCCM-U 32 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 8. Reconnect the optical fiber. 9. Unlock from the OMC the FDDCell object previously locked through step 3. 10. Check the state of the two green RX/TX OPTIC LEDs: they should be ON. 11. Close the door(s) of the Node B. --End-- 33 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 8.1.4 Replacing the pre-cabled 9326 d2U rack Carry out the following procedure to replace the 9326 d2U rack. Intervention time 30 minutes Tools required Screwdrivers Extraction tool CAUTION Laser Class 1 hazards - laser emission During 9326 d2U replacement procedure, never expose the eyes to laser emission of optical transceivers. Never look at the optical cable ferrule since the Remote Radio device is the master for opening the optical communication with the 9326 d2U. This means that the Remote Radio device will transmit a laser signal, even if the optical fiber is disconnected on the 9326 d2U side. CAUTION ESDS handling precautions Wear the antistatic bracelet when performing the maintenance procedure described below. WARNING Service interruption This procedure requires a service interruption from the Node B. 34 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent Figure 9 9326 d2U front view Procedure Step Action 1. Open the door(s) of the Node B. 2. Lock the cem and ccm objects as well as all the objects associated with the Remote Radio devices connected to the iCCM-U at the OMC, by Set Administrative State. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032). 3. Power down the 9326 d2U. To do this, follow the procedure Powering down a 9326 d2U. 4. Remove the management sticker located on the right hand side of the RUC module front panel. This removable sticker contains a 6-digit Network IDentifier (NeID) that is used at 9326 d2U connection to the OMC. This sticker must be stored in a safe location since it will be reused on the new 9326 d2U rack. 35 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 5. Untighten the eight screws from the shielded faceplate, as shown below. 6. Remove the 9326 d2U shielded faceplate, handling with care the associated gasket. 7. Remove the iCEM(s)-U using the extraction tool. 8. Remove the iCCM-U: Unplug the iCCM-U from its RBP connectors using the extraction tool. Disconnect the optical fiber(s) from the iCCM-U front panel. Disconnect the digital cable (connector labeled "ALARM" on the shielded faceplate) from the iCCM-U front panel. Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel. Extract the iCCM-U using the extraction tool. 9. Remove the defective 9326 d2U rack. 36 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 10. Put in place the new 9326 d2U rack. 11. Fix the NeID sticker on the right hand side of the RUC module, on the new 9326 d2U rack. 12. Reinsert the iCEM(s)-U in the new digital shelf. 13. Reinsert the iCCM-U in the new digital shelf: Insert the iCCM-U into the slot guides without plugging it on the RBP. Reconnect the optical fiber(s) on the iCCM-U front panel. Reconnect the digital cable on the iCCM-U front panel. Insert completely the iCCM-U into the digital shelf by plugging it into its RBP connectors. 14. Put in place the shielded faceplate (with the gasket) on the new 9326 d2U rack. 15. Tighten the eight screws on the shielded faceplate. 16. Power up the new 9326 d2U. To do this, follow the procedure Powering up a 9326 d2U. 17. Check the state of the iCEM-U/iCCM-U corporate LEDs. They should turn on, then take the following state: red triangular LED OFF and green rectangular LED ON. 18. Reconnect the E1/T1 connector (PCM link) on the iCCM-U front panel. 19. Unlock from the OMC the objects previously locked through step 2. 20. Connect the TIL on "PORT2" of the 9326 d2U to modify the pre-cabled rack inventory parameters. 21. Launch the TIL. 22. Go to the I&C menu. 37 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 23. Choose Change I&C parameters. 38 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 24. In the Change I&C parameters tabs, choose the BTS tab. 25. The Serialisation number, Manufacturing Date, and Hardware Release fields are linked with the defective 9326 d2U rack. This information must be updated. 39 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 26. Using the information written on the pre-cabled rack sticker present on the front face of the 9326 d2U spare, fill out the Serialisation number, Manufacturing Date, and Hardware Release fields. 27. Click Send to iBTS and wait during the operation. At the end of the operation, the following message is displayed: 40 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 28. Go to the Tools menu. 29. Choose iBTS reset, then Reset in connected mode. 30. In the Confirm the reset window, click OK. 31. In the End of Reset window, click OK. 32. Exit the TIL. 33. Disconnect the TIL from the 9326 d2U. 34. Check the state of the LEDs and display: the iCEM-U/iCCM-U corporate LEDs should have the following state: red triangular LED OFF and green rectangular LED ON. the green PCM LEDs should be ON. the green RX/TX OPTIC LEDs should be ON. the display should indicate the PCM synchronization. 35. Close the door(s) of the Node B. 41 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide --End-- 42 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 8.2 Replacing the optional equipment This part presents the replacement procedures related to the following items: External Alarm module PCM Lightning Protection (LPPCM) module 43 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 8.2.1 Replacing the External Alarm module Perform the following procedure to replace the External Alarm module. Intervention time Ten minutes Tools required Screwdriver Figure 10 Front panel of the External Alarm module Procedure Step Action 1. Open the door(s) of the Node B. 2. Locate the External Alarm module, just below the 9326 d2U rack. 3. On the External Alarm module, disconnect the following cables from the front panel connectors: the two external alarm cables the alarm cable that connects the alarm module to the LPPCM module (if exists) the private alarm bus cable that is connected to the front panel of the RUC module the ground cable 44 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent 4. Loosen the four front panel screws. 5. Remove the defective External Alarm module. 6. Insert the new External Alarm module. 7. Tighten the four front panel screws. 8. Reconnect the five cables. 9. Close the door(s) of the Node B. --End-- 45 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 8.2.2 Replacing the LPPCM module Carry out the following procedure to replace the LPPCM module. Intervention time 15 minutes Tools required Screwdriver Wrench for hexagonal head (M6 nut) CAUTION Service interruption This procedure requires a service interruption of the 9326 d2U. Figure 11 LPPCM module front panel 46 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent Procedure Step Action 1. Open the door(s) of the Node B. 2. Locate the LPPCM module, just above the 9326 d2U rack. 3. Disconnect the cables connected on the LPPCM front panel: the "PCM Out" cable that is connected to the iCCM-U the "IN" alarm bus cable that is connected to the External Alarm module the PCM cable ("PCM In") the ground cable 4. Loosen the two front panel screws. 5. Remove the defective LPPCM module. 6. Insert the new LPPCM module. 7. Tighten the two front panel screws. 8. Reconnect the four cables. 9. Close the door(s) of the Node B. --End-- 47 Copyright 2007-2009 Alcatel-Lucent Maintenance Guide 48 NN-20500-110 03.03/EN Standard May 2009 Copyright 2007-2009 Alcatel-Lucent Wireless Service Provider Solutions W-CDMA Alcatel-Lucent 9326 digital 2U Node B Maintenance Guide Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction Copyright 2007-2009 Alcatel-Lucent, All Rights Reserved UNCONTROLLED COPY: The master of this document is stored on an electronic database and is "write protected"; it may be altered only by authorized persons. While copies may be printed, it is not recommended. Viewing of the master electronically ensures access to the current issue. Any hardcopies taken must be regarded as uncontrolled copies. ALCATEL-LUCENT CONFIDENTIAL: The information contained in this document is the property of Alcatel-Lucent. Except as expressly authorized in writing by Alcatel-Lucent, the holder shall keep all information contained herein confidential, shall disclose the information only to its employees with a need to know, and shall protect the information from disclosure and dissemination to third parties. Except as expressly authorized in writing by Alcatel-Lucent, the holder is granted no rights to use the information contained herein. If you have received this document in error, please notify the sender and destroy it immediately. Alcatel-Lucent, Alcatel, Lucent Technologies and their respective logos are trademarks and service marks of Alcatel-Lucent, Alcatel and Lucent Technologies. All other trademarks are the property of their owners. Document number: NN-20500-110 Document issue: 03.03/EN Document status: Standard Product Release: UA06.0 Date: May 2009