You are on page 1of 49

NN-20500-110

Wireless Service Provider Solutions


W-CDMA
Alcatel-Lucent 9326 digital 2U Node B
Maintenance Guide
NN-20500-110 03.03/EN Standard May 2009
Wireless Service Provider Solutions
W-CDMA
Alcatel-Lucent 9326 digital 2U Node B
Maintenance Guide
Document number: NN-20500-110
Document issue: 03.03/EN
Document status: Standard
Product release: UA06.0
Date: May 2009
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction
Copyright 2007-2009 Alcatel-Lucent, All Rights Reserved
UNCONTROLLED COPY: The master of this document is stored on an electronic database and is "write
protected"; it may be altered only by authorized persons. While copies may be printed, it is not
recommended. Viewing of the master electronically ensures access to the current issue. Any hardcopies
taken must be regarded as uncontrolled copies.
ALCATEL-LUCENT CONFIDENTIAL: The information contained in this document is the property of
Alcatel-Lucent. Except as expressly authorized in writing by Alcatel-Lucent, the holder shall keep all
information contained herein confidential, shall disclose the information only to its employees with a need
to know, and shall protect the information from disclosure and dissemination to third parties. Except as
expressly authorized in writing by Alcatel-Lucent, the holder is granted no rights to use the information
contained herein. If you have received this document in error, please notify the sender and destroy it
immediately.
Alcatel-Lucent, Alcatel, Lucent Technologies and their respective logos are trademarks and service marks
of Alcatel-Lucent, Alcatel and Lucent Technologies.
All other trademarks are the property of their owners.
PUBLICATION HISTORY
SYSTEM RELEASE: UA06.0
May 2009
Issue 03.03/EN Preliminary
Update for DR5
November 2008
Issue 03.02/EN Preliminary
Update after internal review
July 2008
Issue 03.01/EN Preliminary
Editorial update for UA06.0
SYSTEM RELEASE: UA05.1
April 2008
Issue 02.01/EN Standard
Update for UA05.1.2
SYSTEM RELEASE: UA05.0
September 2007
Issue 01.03/EN Standard
Update for UA05.0 Channel Readiness
SYSTEM RELEASE: UA04.2.7
May 2007
Issue 01.02/EN Preliminary
Update after internal review
April 2007
Issue 01.01/EN Draft
Publication history 3
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
Creation for UA04.2.7 T
Publication history 4
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
1 About this publication................................................................................................................................................... 7
2 Access Network Roadmap............................................................................................................................................ 9
3 New in this release....................................................................................................................................................... 10
4 Corrective maintenance activity................................................................................................................................. 11
5 9326 d2U introduction..................................................................................................................................................14
6 9326 d2U hardware presentation................................................................................................................................ 16
7 9326 d2U power up and power down procedures.....................................................................................................18
7.1 Powering up a 9326 d2U......................................................................................................................................... 19
7.2 Powering down a 9326 d2U.....................................................................................................................................20
8 9326 d2U corrective maintenance procedures..........................................................................................................21
8.1 Replacing the digital shelf equipment....................................................................................................................... 22
8.1.1 Replacing the iCEM-U........................................................................................................................................ 23
8.1.2 Replacing the iCCM-U........................................................................................................................................26
8.1.3 Replacing an optical transceiver........................................................................................................................ 31
8.1.4 Replacing the pre-cabled 9326 d2U rack........................................................................................................... 34
8.2 Replacing the optional equipment............................................................................................................................ 43
8.2.1 Replacing the External Alarm module................................................................................................................ 44
8.2.2 Replacing the LPPCM module........................................................................................................................... 46
Table of contents 5
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
Figure 1 - Outside view of the 9326 d2U............................................................................................................ ......... 15
Figure 2 - 9326 d2U pyramidal view (without shielded faceplate)......................................................... ............. ......... 16
Figure 3 - 9326 d2U front view.............................................................................................................. ............. ......... 17
Figure 4 - Location of modules in the 9326 d2U................................................................................... ............. ......... 17
Figure 5 - iCEM-U front panel............................................................................................................... ............. ......... 23
Figure 6 - iCCM-U front panel............................................................................................................... ............. ......... 27
Figure 7 - Location of optical connectors in the 9326 d2U.................................................................... ............. ......... 32
Figure 8 - Inserting an SFP transceiver in the iCCM-U......................................................................... ............. ......... 32
Figure 9 - 9326 d2U front view.............................................................................................................. ............. ......... 35
Figure 10 - Front panel of the External Alarm module.......................................................................... ............. ......... 44
Figure 11 - LPPCM module front panel................................................................................................. ............. ......... 46
List of figures 6
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
1 About this publication
This publication describes the corrective maintenance procedures applicable to the 9326 d2U rack.
Note: This publication only describes maintenance procedures relating to 9326 d2U V1 product.
For detailed information on 9326 d2U V2 maintenance, refer to the following document:
Alcatel-Lucent 9326 digital 2U Node B V2 - Maintenance Guide (NN-20500-204).
Applicability
This publication applies to UA06.0.
Audience
The publication is intended for operation and maintenance personnel and for those who want to know
the principles of 9326 d2U maintenance.
Prerequisites
It is recommended that readers become familiar with the following publications:
Alcatel-Lucent 9326 digital 2U Node B - Technical Description (NN-20500-108)
Alcatel-Lucent 9300 W-CDMA Product Family documentation:
Terminology (NN-20500-002)
Node B Alarms Reference Guide (NN-20500-018)
Alcatel-Lucent Node B - Commissioning & Fault Management User Manual: TIL (NN-20500-019)
How this publication is organized
This publication consists of eight parts:
The first chapter lists what is new in this publication.
The second part describes the corrective maintenance activity.
The third part introduces the 9326 d2U rack.
The fourth part presents the 9326 d2U hardware.
The fifth part describes the pre-requisite procedure.
The sixth part describes the power up and power down procedures.
The last part describes the corrective maintenance procedures.
Vocabulary conventions
For a list of terms used in this publication, see Alcatel-Lucent 9300 W-CDMA Product Family -
Terminology (NN-20500-002).
7
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
Safety regulation
In order to guarantee the safety of personnel and equipment the following aspects must be taken into
account:
general personnel safety instructions
equipment safety instructions
Caution, warning, and danger messages indicate the following possible risks.
CAUTION
Impact on service and on the equipment
DANGER
Electric shock
DANGER
Environment and personnel protection
CAUTION
ElectroStatic Discharge Sensitive (ESDS) handling precautions
8
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
2 Access Network Roadmap
For collection roadmap, see Alcatel-Lucent 9300 W-CDMA Product Family - Document Collection
Overview and Update Summary (NN-20500-050).
9
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
3 New in this release
The following sections detail what is new in Alcatel-Lucent 9326 digital 2U Node B - Maintenance
Guide for UA06.0.
Features
None
Other changes
Review comments added
10
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
4 Corrective maintenance activity
This part describes the corrective maintenance activity applicable to the 9326 d2U rack.
Corrective maintenance
The network maintenance is based on the supervision of the network, by using the OAM graphical
interface. For more information, refer to Alcatel-Lucent 9353 Management System - User Guide
(NN-20500-032).
It is also based on the identification and replacement of faulty items of equipment, using the alarms.
The process is divided into the following two steps:
locating and identifying the faulty items of equipment, by using the information provided in
Alcatel-Lucent 9300 W-CDMA Product Family - Node B Alarms Reference Guide
(NN-20500-018).
replacing the faulty items of equipment, by using the replacement procedures given in this
document.
Replacing the digital shelf equipment
Procedure Product Engineering
Code (PEC)
Common Product
Code (CPC)
Impact on service
Replacing the iCEM-U NTUM36AA N0099941 Loss of capacity or
loss of service
(depending on the
number of iCEM-U in
the digital shelf)
Replacing the iCCM-U NTUM36MA N0099944 Loss of service on
the Remote Radio
device(s) associated
with the iCCM-U be-
ing replaced
Replacing an optical
transceiver
Single-Mode (SM):
NTU850HA
Single-Mode (SM):
N0146844
Loss of service on
the Remote Radio
device associated
with the optical trans-
ceiver being replaced
Multi-Mode (MM):
NTU850HM
Multi-Mode (MM):
N0146845
Replacing the pre-
cabled 9326 d2U rack
NTU808AA N0143700 Service interruption
11
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
Replacing the optional equipment
Procedure Product Engineering
Code (PEC)
Common Product
Code (CPC)
Impact on service
Replacing the LPPCM
module
NTU870GM N0146847 None
Replacing the External
Alarm module
NTU870GA N0146846 None
Description of a replacement procedure
A replacement procedure is divided into the following parts:
the title
the main body with the following information:
the intervention time
the tools required
the impact of the procedure, if necessary
the step-by-step actions of the procedure
One or more figures are provided to help you execute the actions. They show the FRU
schematically and its location in the cabinet.
Intervention restrictions
There may be a lapse of time between the identification of the alarm at the Access OAM Graphic
User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by telephone)
before an on-site intervention, in the following cases:
isolating procedures
completion of an on-site intervention
return to service procedure
General personnel safety instructions
The personnel must obey the safety instructions specific to the installation site:
rules concerning the premises (see instructions posted on site or in the building)
rules linked to general personnel safety instructions
The personnel working on the cabinet must be authorized to work according to security standards.
12
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
Equipment safety instructions
The 9326 d2U normally operates when the external temperature is between -5C and +65C.
13
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
5 9326 d2U introduction
The 9326 d2U is a digital rack designed to be connected to one of the following products via optical
fiber links:
9341 RRH20-21
9341 RRH40
9332 rCompact OD
The Alcatel-Lucent Remote Radio solution improves flexibility for deploying mobile broadband Node
Bs in space-constrained locations. It is particularly suited to macro-cellular application in dense
areas, where site acquisition is difficult, and on sites where installation constraints prevent the use of
legacy Node Bs.
Compared to legacy Node B site deployment, the Remote Radio solution provides the following
benefits:
reduced volume, weight, footprint, acoustic noise, and power consumption
reduced cost of feeder paths from the Node B to the antenna
increased RF power per carrier at the antenna feeder
reduced radio loss with use of the remote RF block concept, which eliminates the distance
between the radio amplifier and the antenna
The Remote Radio solution provides for the UMTS system:
the means of communication between a User Equipment (UE) and a network using Transport
Channels
physical layer channels, which are necessary to synchronize the downlink and perform cell
selection/reselection and handover preparation
measurement information to the UMTS RNC for radio resource management (handover, power
control)
The 9326 d2U provides up to eight E1/T1 with Inversion Multiplexing ATM (IMA) or Drop-and-Insert
capability (fractional E1/T1). The 9326 d2U also supports multi-PCM without IMA.
The 9326 d2U delivers high UMTS radio performances and supports the enhanced High Speed
Downlink Packet Access (HSDPA) and High Speed Uplink Packet Access (HSUPA) solutions
through easy software upgrade.
The Alcatel-Lucent 9326 d2U solution is compliant with the Common Protocol Radio Interface
(CPRI).
14
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
9326 d2U enclosure
The 9326 d2U provides the operators with a suited solution whatever the site constraints are.
The 9326 d2U can be installed in a standalone indoor mode or in the user space of an existing indoor
or outdoor Node B cabinet.
The 9326 d2U is factory-equipped with a specific shielded faceplate.
The following figure shows an outside view of the 9326 d2U.
Figure 1 Outside view of the 9326 d2U
15
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
6 9326 d2U hardware presentation
The 9326 d2U is built around the following components:
a mechanical enclosure (including two fans), compatible with standard 19-inch rack installation
a digital shelf including the digital modules and the associated digital backplane
a commissioning module located on the right hand side of the digital shelf
a shielded faceplate
The following figure shows a pyramidal view of the 9326 d2U (without shielded faceplate).
Figure 2 9326 d2U pyramidal view (without shielded faceplate)
The following figure shows the front view of the 9326 d2U.
16
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
Figure 3 9326 d2U front view
The following figure shows the location of modules in the 9326 d2U (without shielded faceplate).
Figure 4 Location of modules in the 9326 d2U
17
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
7 9326 d2U power up and power down procedures
This part describes how to power up and power down the 9326 d2U rack.
18
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
7.1 Powering up a 9326 d2U
Perform the following procedure to power up a 9326 d2U.
Initial check
On the RUC module, check that the power switch is in the "O" position.
Procedure
Step Action
1. At the operator DC power supply, put the site circuit breaker of the 9326 d2U in the "ON"
position.
2. On the RUC module, put the power switch in the "I" position.
3. Check that the fans are starting up.
4. On the iCCM-U and on each iCEM-U, check that:
the green LED is ON.
the red LED is OFF.
--End--
19
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
7.2 Powering down a 9326 d2U
Perform the following procedure to power down a 9326 d2U.
Procedure
Step Action
1. Preliminary operation: make sure that the btsSiteManager object is "locked".
2. On the RUC module, put the power switch in the "O" position.
3. Check that the green or red LED on the iCCM-U and on each iCEM-U is OFF.
4. Check that the fans are stopping down.
5. At the operator DC power supply, put the site circuit breaker of the 9326 d2U in the "OFF"
position.
--End--
20
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
8 9326 d2U corrective maintenance procedures
This part contains the replacement procedures applicable to the 9326 d2U rack.
21
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
8.1 Replacing the digital shelf equipment
This part presents the replacement procedures applicable to the digital shelf.
Those replacement procedures concern the following modules:
integrated Channel Element Module-U (iCEM-U)
integrated Core Control Module-U (iCCM-U)
optical transceiver
9326 d2U pre-cabled rack
22
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
8.1.1 Replacing the iCEM-U
Carry out the following procedure to replace an iCEM-U.
Intervention time
Ten minutes
Tools required
Screwdriver
Extraction tool
CAUTION
ESDS handling precautions
Wear the antistatic bracelet when performing the maintenance
procedure described below.
WARNING
Service interruption
This procedure causes a loss of capacity or a loss of service
(depending on the number of iCEMs-U in the digital shelf).
Figure 5 iCEM-U front panel
23
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
Procedure
Step Action
1. Open the door(s) of the Node B.
2. Locate the faulty iCEM-U in the digital shelf: its red triangular LED is ON.
3. Lock the faulty cem object at the OMC by Set Administrative State. For more information, refer to
Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032).
4. Untighten the eight screws from the shielded faceplate, as shown below.
5. Remove the 9326 d2U shielded faceplate, handling with care the associated gasket.
6. Remove the defective iCEM-U using the extraction tool.
24
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
7. Check the release of the new iCEM-U.
8. Insert the new iCEM-U into the digital shelf.
9. Check the state of the LEDs. They should go on, then take the following state:
red triangular LED OFF and green rectangular LED ON
10. Put in place the shielded faceplate, taking care not to damage the associated gasket.
11. Tighten the eight screws on the shielded faceplate.
12. Close the door(s) of the Node B.
--End--
25
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
8.1.2 Replacing the iCCM-U
Carry out the following procedure to replace the iCCM-U.
Intervention time
20 minutes
Tools required
Screwdriver
Extraction tool
CAUTION
Laser Class 1 hazards - laser emission
During the iCCM-U replacement procedure, never expose the eyes
to laser emission of optical transceivers.
Never look at the optical cable ferrule since the Remote Radio
device is the master for opening the optical communication with the
9326 d2U. This means that the Remote Radio device will transmit a
laser signal, even if the optical fiber is disconnected on the 9326
d2U side.
CAUTION
ESDS handling precautions
Wear the antistatic bracelet when performing the maintenance
procedure described below.
WARNING
Service interruption
This procedure requires a service interruption from the Node B.
26
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
Figure 6 iCCM-U front panel
Procedure
Step Action
1. Open the door(s) of the Node B.
2.
CAUTION
Service interruption
There will be a loss of service on the Remote Radio device(s)
associated with the iCCM-U being replaced.
Lock all the objects associated with the Remote Radio devices connected to the faulty iCCM-U at
the OMC by Set Administrative State. For more information, refer to Alcatel-Lucent 9353
Management System - User Guide (NN-20500-032).
3. Power down the 9326 d2U.
To do this, follow the procedure Powering down a 9326 d2U.
27
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
4. Untighten the eight screws from the shielded faceplate, as shown below.
5. Remove the 9326 d2U shielded faceplate, handling with care the associated gasket.
6. Unplug the iCCM-U from its RBP connectors using the extraction tool.
7. Disconnect the optical fiber(s) from the iCCM-U front panel.
8. Remove the SFP transceiver(s) from the iCCM-U front panel.
9. Disconnect the digital cable (connector labeled "ALARM" on the shielded faceplate) from the
iCCM-U front panel.
10. Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel.
11. Extract the defective iCCM-U using the extraction tool.
12. Insert the new iCCM-U into the slot guides without plugging it on the RBP.
28
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
13. Reinsert the SFP transceiver(s) through the iCCM-U front panel.
14.
CAUTION
Sense for Multi-Mode LC connectors
In case of an iCCM-U equipped with MM SFP transceivers,
when reconnecting the optical fibers on the iCCM-U front panel,
put the LC connectors (L/R) in the same sense as they were
before the intervention.
Reconnect the optical fiber(s) on the iCCM-U front panel.
15. Reconnect the digital cable on the iCCM-U front panel.
16. Insert completely the new iCCM-U into the digital shelf by plugging it into its RBP connectors.
29
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
17. Put in place the shielded faceplate, taking care not to damage the associated gasket.
18. Tighten the eight screws on the shielded faceplate.
19. Power up the 9326 d2U.
To do this, follow the procedure Powering up a 9326 d2U.
20. Check the state of the iCEM-U/iCCM-U corporate LEDs.
They should turn on, then take the following state: red triangular LED OFF and green rectangular
LED ON.
21. Reconnect the E1/T1 connector (PCM link) on the iCCM-U front panel.
22. Unlock from the OMC the objects previously locked through step 2.
23. Check the state of the LEDs and display:
the iCEM-U/iCCM-U corporate LEDs should have the following state: red triangular LED OFF
and green rectangular LED ON.
the green PCM LEDs should be ON.
the display should indicate the PCM synchronization.
24. Close the door(s) of the Node B.
--End--
30
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
8.1.3 Replacing an optical transceiver
Carry out the following procedure to replace a defective optical transceiver.
Intervention time
Five minutes
Tools required
None
CAUTION
Laser Class 1 hazards - laser emission
During this replacement procedure, never expose your eyes to
laser emission of optical transceiver.
Never look at the optical cable ferrule since the Remote Radio
device is the master for opening the optical communication with the
9326 d2U. This means that the Remote Radio device will transmit a
laser signal, even if the optical fiber is disconnected on the 9326
d2U side.
CAUTION
ESDS handling precautions
Wear the antistatic bracelet when performing the maintenance
procedure described below.
Procedure
Step Action
1. Open the door(s) of the Node B.
2. Locate the faulty SFP transceiver: its two green RX/TX OPTIC LEDs (close to the eight PCM
LEDs) are OFF.
31
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
Figure 7 Location of optical connectors in the 9326 d2U
3. At the OMC, through Set Administrative State, lock the FDDCell object associated with the
Remote Radio device connected to the optical transceiver being replaced.
4. Disconnect the optical fiber connected to the defective SFP transceiver (optical output labeled
"OPTIC1", "OPTIC2" or "OPTIC3").
5. Extract with care the defective SFP transceiver.
6. Check that the new replacing SFP transceiver has the same type as the SFP transceiver being
replaced.
Be sure to replace a SM SFP transceiver with a SM SFP transceiver and a MM SFP transceiver
with a MM SFP transceiver.
7. Put in place the new SFP transceiver and insert it in the iCCM-U.
Figure 8 Inserting an SFP transceiver in the iCCM-U
32
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
8. Reconnect the optical fiber.
9. Unlock from the OMC the FDDCell object previously locked through step 3.
10. Check the state of the two green RX/TX OPTIC LEDs: they should be ON.
11. Close the door(s) of the Node B.
--End--
33
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
8.1.4 Replacing the pre-cabled 9326 d2U rack
Carry out the following procedure to replace the 9326 d2U rack.
Intervention time
30 minutes
Tools required
Screwdrivers
Extraction tool
CAUTION
Laser Class 1 hazards - laser emission
During 9326 d2U replacement procedure, never expose the eyes to
laser emission of optical transceivers.
Never look at the optical cable ferrule since the Remote Radio
device is the master for opening the optical communication with the
9326 d2U. This means that the Remote Radio device will transmit a
laser signal, even if the optical fiber is disconnected on the 9326
d2U side.
CAUTION
ESDS handling precautions
Wear the antistatic bracelet when performing the maintenance
procedure described below.
WARNING
Service interruption
This procedure requires a service interruption from the Node B.
34
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
Figure 9 9326 d2U front view
Procedure
Step Action
1. Open the door(s) of the Node B.
2. Lock the cem and ccm objects as well as all the objects associated with the Remote Radio
devices connected to the iCCM-U at the OMC, by Set Administrative State. For more information,
refer to Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032).
3. Power down the 9326 d2U.
To do this, follow the procedure Powering down a 9326 d2U.
4. Remove the management sticker located on the right hand side of the RUC module front panel.
This removable sticker contains a 6-digit Network IDentifier (NeID) that is used at 9326 d2U
connection to the OMC. This sticker must be stored in a safe location since it will be reused on
the new 9326 d2U rack.
35
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
5. Untighten the eight screws from the shielded faceplate, as shown below.
6. Remove the 9326 d2U shielded faceplate, handling with care the associated gasket.
7. Remove the iCEM(s)-U using the extraction tool.
8. Remove the iCCM-U:
Unplug the iCCM-U from its RBP connectors using the extraction tool.
Disconnect the optical fiber(s) from the iCCM-U front panel.
Disconnect the digital cable (connector labeled "ALARM" on the shielded faceplate) from the
iCCM-U front panel.
Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel.
Extract the iCCM-U using the extraction tool.
9. Remove the defective 9326 d2U rack.
36
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
10. Put in place the new 9326 d2U rack.
11. Fix the NeID sticker on the right hand side of the RUC module, on the new 9326 d2U rack.
12. Reinsert the iCEM(s)-U in the new digital shelf.
13. Reinsert the iCCM-U in the new digital shelf:
Insert the iCCM-U into the slot guides without plugging it on the RBP.
Reconnect the optical fiber(s) on the iCCM-U front panel.
Reconnect the digital cable on the iCCM-U front panel.
Insert completely the iCCM-U into the digital shelf by plugging it into its RBP connectors.
14. Put in place the shielded faceplate (with the gasket) on the new 9326 d2U rack.
15. Tighten the eight screws on the shielded faceplate.
16. Power up the new 9326 d2U.
To do this, follow the procedure Powering up a 9326 d2U.
17. Check the state of the iCEM-U/iCCM-U corporate LEDs.
They should turn on, then take the following state: red triangular LED OFF and green rectangular
LED ON.
18. Reconnect the E1/T1 connector (PCM link) on the iCCM-U front panel.
19. Unlock from the OMC the objects previously locked through step 2.
20. Connect the TIL on "PORT2" of the 9326 d2U to modify the pre-cabled rack inventory
parameters.
21. Launch the TIL.
22. Go to the I&C menu.
37
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
23. Choose Change I&C parameters.
38
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
24. In the Change I&C parameters tabs, choose the BTS tab.
25. The Serialisation number, Manufacturing Date, and Hardware Release fields are linked with
the defective 9326 d2U rack. This information must be updated.
39
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
26. Using the information written on the pre-cabled rack sticker present on the front face of the 9326
d2U spare, fill out the Serialisation number, Manufacturing Date, and Hardware Release
fields.
27. Click Send to iBTS and wait during the operation. At the end of the operation, the following
message is displayed:
40
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
28. Go to the Tools menu.
29. Choose iBTS reset, then Reset in connected mode.
30. In the Confirm the reset window, click OK.
31. In the End of Reset window, click OK.
32. Exit the TIL.
33. Disconnect the TIL from the 9326 d2U.
34. Check the state of the LEDs and display:
the iCEM-U/iCCM-U corporate LEDs should have the following state: red triangular LED OFF
and green rectangular LED ON.
the green PCM LEDs should be ON.
the green RX/TX OPTIC LEDs should be ON.
the display should indicate the PCM synchronization.
35. Close the door(s) of the Node B.
41
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
--End--
42
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
8.2 Replacing the optional equipment
This part presents the replacement procedures related to the following items:
External Alarm module
PCM Lightning Protection (LPPCM) module
43
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
8.2.1 Replacing the External Alarm module
Perform the following procedure to replace the External Alarm module.
Intervention time
Ten minutes
Tools required
Screwdriver
Figure 10 Front panel of the External Alarm module
Procedure
Step Action
1. Open the door(s) of the Node B.
2. Locate the External Alarm module, just below the 9326 d2U rack.
3. On the External Alarm module, disconnect the following cables from the front panel connectors:
the two external alarm cables
the alarm cable that connects the alarm module to the LPPCM module (if exists)
the private alarm bus cable that is connected to the front panel of the RUC module
the ground cable
44
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
4. Loosen the four front panel screws.
5. Remove the defective External Alarm module.
6. Insert the new External Alarm module.
7. Tighten the four front panel screws.
8. Reconnect the five cables.
9. Close the door(s) of the Node B.
--End--
45
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
8.2.2 Replacing the LPPCM module
Carry out the following procedure to replace the LPPCM module.
Intervention time
15 minutes
Tools required
Screwdriver
Wrench for hexagonal head (M6 nut)
CAUTION
Service interruption
This procedure requires a service interruption of the 9326 d2U.
Figure 11 LPPCM module front panel
46
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
Procedure
Step Action
1. Open the door(s) of the Node B.
2. Locate the LPPCM module, just above the 9326 d2U rack.
3. Disconnect the cables connected on the LPPCM front panel:
the "PCM Out" cable that is connected to the iCCM-U
the "IN" alarm bus cable that is connected to the External Alarm module
the PCM cable ("PCM In")
the ground cable
4. Loosen the two front panel screws.
5. Remove the defective LPPCM module.
6. Insert the new LPPCM module.
7. Tighten the two front panel screws.
8. Reconnect the four cables.
9. Close the door(s) of the Node B.
--End--
47
Copyright 2007-2009 Alcatel-Lucent
Maintenance Guide
48
NN-20500-110 03.03/EN Standard May 2009
Copyright 2007-2009 Alcatel-Lucent
Wireless Service Provider Solutions
W-CDMA
Alcatel-Lucent 9326 digital 2U Node B
Maintenance Guide
Alcatel-Lucent - Internal - Proprietary - Use pursuant to Company instruction
Copyright 2007-2009 Alcatel-Lucent, All Rights Reserved
UNCONTROLLED COPY: The master of this document is stored on an electronic database and is "write protected"; it may be altered
only by authorized persons. While copies may be printed, it is not recommended. Viewing of the master electronically ensures access
to the current issue. Any hardcopies taken must be regarded as uncontrolled copies.
ALCATEL-LUCENT CONFIDENTIAL: The information contained in this document is the property of Alcatel-Lucent. Except as
expressly authorized in writing by Alcatel-Lucent, the holder shall keep all information contained herein confidential, shall disclose the
information only to its employees with a need to know, and shall protect the information from disclosure and dissemination to third
parties. Except as expressly authorized in writing by Alcatel-Lucent, the holder is granted no rights to use the information contained
herein. If you have received this document in error, please notify the sender and destroy it immediately.
Alcatel-Lucent, Alcatel, Lucent Technologies and their respective logos are trademarks and service marks of Alcatel-Lucent, Alcatel
and Lucent Technologies.