You are on page 1of 359

WOOD GROUP ESP, INC.

USA STANDARD TERMS AND CONDITIONS OF SALE



1. INTERPRETATION
In these Standard Terms and Conditions:
Buyer means the person, firm or company with whom the Contract is made;
Buyer Group means the Buyer, its co-venturers, its and their respective affiliates and agents and its and their respective directors,
officers and employees;
Contract means the contract between the Seller and the Buyer for the sale and purchase of the Products and/or Services,
incorporating these Standard Terms and Conditions;
Order Acknowledgement means the written acceptance by Seller of Buyers purchase order or specification which shall
incorporate these Standard terms and Conditions which forms the Contract;
Product(s) means any products or parts agreed in the Contract to be supplied to the Buyer by the Seller;
Seller means the selling entity identified in the Order Acknowledgement, or if none, the quotation;
Seller Group means the Seller, its sub-suppliers, its and their respective affiliates and agents, its and their respective directors,
officers and employees;
Services means any services agreed in the Contract to be supplied to the Buyer by the Seller;
Special Conditions means those Special Terms and Conditions set out in the Order Acknowledgement or other document issued by
the Seller.

2. APPLICABILITY
2.1 Subject to any variation under Section 2.3, the Contract shall be on these Standard Terms and Conditions to the exclusion of all other
terms and conditions (including any terms and conditions which the Buyer purports to apply under any purchase order, confirmation of
order, specification or other document).
2.2 No terms or conditions endorsed on, delivered with or contained in the Buyers purchase order, confirmation of order, specification or
other documents shall form part of the Contract simply as a result of such document being referred to in the Contract.
2.3 These Standard Terms and Conditions apply to all the Sellers sales and any variations to these Standard Terms and Conditions and
any representations about the Products shall have no effect unless expressly agreed in writing and signed by an Authorized Signatory of the
Seller. The Buyer acknowledges that it has not relied on any statement, promise or representation made or given by or on behalf of the
Seller which is not set out in the Contract.
2.4 Each order or acceptance of a quotation for Products by the Buyer from the Seller shall be deemed to be an offer by the Buyer to buy
Products subject to these Standard Terms and Conditions.
2.5 No order placed by the Buyer shall be deemed to be accepted by the Seller until an Order Acknowledgement is issued by the Seller,
or (if earlier), the Seller delivers the Products or Services to the Buyer.
2.6 The Buyer shall ensure that the terms of its order and any applicable specification are complete and accurate.
2.7 Any quotation is given on the basis that no Contract shall come into existence until the Seller dispatches an Order Acknowledgement
or delivers the Products or Services to the Buyer. Any quotation is valid for a period of 30 days only from its date, provided that the
Seller has not previously withdrawn it. All quotations of Seller are subject to change at any time.
3. PRICES
All prices are subject to change without notice. Prices do not include packing and preparation of export shipment, inland or ocean
freight, loading, unloading, carriage, insurance or forwarding fees, taxes, or duties of any kind or other similar charges applicable to the
Products, Services and/or the Contract. Buyer agrees to pay such charges incurred by Seller on Buyers behalf together with additional
handling charges upon receipt of Sellers invoice for the same.

4. TERMS OF PAYMENT
Unless Seller and Buyer otherwise agree in writing to payment terms other than those specified herein, payment shall be made in U.S.
dollars in accordance with remittance instructions furnished by Seller.
(i) All payments shall be made within thirty (30) days after date of Sellers invoice.
(ii) Time for payment shall be of the essence.
(iii) Seller may suspend credit to Buyer and may withhold shipment of Products ordered, suspend or cancel performance under
these Standard Terms and Conditions if in its sole judgment the financial condition of the Buyer warrants such action.
Suspension of performance may result in rescheduling delays.
(iv) Prices do not include applicable taxes or duties. Buyer is solely responsible for paying all applicable taxes and duties. Seller
will add taxes to the price where required by applicable law, and Buyer will pay all such taxes unless Buyer provides Seller
with a duly executed tax exemption certificate in a form satisfactory to the Seller. If Buyer is required by applicable law to
withhold any amount of tax from its payment to Seller, Buyer shall promptly pay such amount to the appropriate tax
authority and take all reasonable steps to minimize such withholding tax. Buyer shall take all steps required to promptly obtain
and deliver to Seller the appropriate certification of any such withholding in a form satisfactory to the Seller.
(v) The Buyer shall make all payments due under the Contract in full without any deduction whether by way of set-off,
counterclaim, discount, abatement or otherwise.
(vi) All payments payable to the Seller under the Contract shall become due immediately on its termination despite any other
provision.


Page 1 of 5




(vii) If the Buyer fails to pay the Seller any sum due pursuant to the Contract, the Buyer shall be liable to pay interest to the Seller
on such sum from the due date for payment at the rate of eighteen percent (18%) per annum or at the highest rate allowed by
law.
5. SHIPPING, DELIVERY, TITLE & RISK OF LOSS
Products shall be delivered EXW (at location named by the Seller) (Incoterms 2000). Risk for loss or damage shall pass to Buyer upon
Sellers delivery to Buyer. Title shall pass to the Buyer upon receipt of payment in cleared funds by the Seller of amounts due in respect
of the Contract.

Seller may deliver the Products in installments. Each installment shall be a separate Contract and no cancellation or termination of any
one Contract relating to an installment shall entitle the Buyer to repudiate or cancel any other Contract or installment. Delivery dates
are intended to be an estimate and time and date for delivery shall not be made of the essence by notice or otherwise and are dependent
on prompt receipt by Seller of all information and assistance required or requested by Seller to permit Seller to carry out its obligations
under the Contract. Seller shall not be liable for any damage, losses or expenses incurred by Buyer if Seller fails to meet the estimated
delivery dates.

In the event that Products are not collected by Buyer on actual date of delivery, Seller may (at its sole discretion) place Products in
storage at the sole cost, expense and risk of the Buyer.

6. FORCE MAJEURE
Seller reserves the right to defer the date of delivery of Products and/or the date of performance of Services, to cancel the Contract, or
reduce the volume of the Products and/or amend the scope of the Services ordered by Buyer (without liability to Buyer) if it is
prevented from or delayed in the carrying out of its business due to circumstances beyond its reasonable control, including but not
limited to, natural disasters, forces of nature, earthquake, tidal wave, landslide, flood, lightening, hurricane, typhoon, storm or other
weather condition not included in normal planning, epidemic and plague; changes in law or regulations, governmental actions; acts of
civil or military authority; fire; explosion; lock-outs, strikes and/or labor disputes (whether or not relating to either partys workforce);
civil commotion; protests; war; national emergency; riot; civil insurrection; acts of terrorism; restraints or delays in transportation;
restraints or delays in manufacturing and inability of Seller to obtain adequate or suitable supplies from usual sources, or acts of Buyer
resulting in commercial impracticality. In the event of any such delay, the date of delivery and/or performance shall be deferred for a
period equal to the time lost by reason of the delay.

7. WARRANTY
Seller warrants that Products manufactured by Seller, when properly stored, commissioned, installed, used and maintained, and
Services performed by the Seller, shall be free from defects in material and workmanship. Sellers obligation under this warranty shall
be limited to replacing or repairing the part or parts or, the Products, at Sellers option, which prove to be defective in material or
workmanship within twelve (12) months from the date of installation or eighteen (18) months from the date of delivery, whichever
shall occur first, or reperforming Services within twelve (12) months of the Services being supplied (WARRANTY PERIOD),
provided the Buyer gives Seller prompt notice of any defect and provides proof in a form and substance satisfactory to the Seller
(acting in its sole discretion) including all relevant data and documentation needed to assess well and equipment performance and
operations. Any defective part or parts must be returned freight prepaid by Buyer to an authorized service center designated by Seller
for inspection. Seller will deliver any replacements for defective Products to Buyer prepaid to the delivery destination provided by the
original order. Products returned to the Seller for which Seller provides replacement under this warranty shall become the property of
the Seller.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, WHETHER ORAL,
WRITTEN, EXPRESSED, IMPLIED OR STATUTORY, AND SELLER MAKES NO WARRANTY AS TO FITNESS FOR
PURPOSE OR MERCHANTABILITY. SELLERS WARRANTY OBLIGATIONS AND BUYERS REMEDIES ARE SOLELY AND
EXCLUSIVELY AS STATED HEREIN.

THE WARRANTY PERIOD SHALL NOT BE EXTENDED FOR REPAIRED OR REPLACED PARTS OR PRODUCTS OR
REPERFORMED SERVICES. SUCH PARTS OR PRODUCTS OR SERVICES SHALL REMAIN UNDER WARRANTY ONLY FOR
THE UNEXPIRED PORTION OF THE WARRANTY PERIOD. SELLERS SOLE LIABILITY SHALL BE AT ITS OPTION TO
REPAIR OR REPLACE PARTS OR PRODUCTS OR REPERFORM SERVICES UNDER THIS CONDITION. SELLER MAY IN ITS
SOLE DISCRETION CREDIT BUYER'S ACCOUNT FOR A PORTION OF SUCH PARTS OR PRODUCTS AND/OR SERVICES
DETERMINED BY SELLER TO BE DEFECTIVE
The foregoing warranty does not apply to: (a) defect caused or contributed to by abrasive materials, corrosion due to aggressive fluids,
lightening, improper voltage supply, mishandling or misapplication; (b) Products or parts which are normally consumed in operation,
or have a normal life inherently shorter than the WARRANTY PERIOD; (c) alterations or repairs carried out without prior written
approval of the Seller, or using equipment and accessories for a purpose other than that for which such equipment and accessories are
intended; (d) installations carried out by the Buyer unless Buyers engineers have been appropriately trained and certified by Seller;
(e) installations in which Buyer has not used the application engineering practices for the Products as approved by Supplier; (f)
defective Products or Services where Buyer makes further use of the Products after the earlier of the Buyers awareness of the defect or the
time when the Buyer ought to have become aware of such defect; (g) defects arising from or in connection with information, drawings,
chart interpretations, technical specifications or instructions provided by the Buyer to the Seller.


Page 2 of 5




8. LIMITATION OF LIABILITY
(i) FOR THE PURPOSE OF THIS SECTION 8(i), THE EXPRESSION "CONSEQUENTIAL LOSS" SHALL MEAN (IN EACH
CASE WHETHER OR NOT FORESEEABLE AT THE DATE OF THE CONTRACT): (a) ANY AND ALL
CONSEQUENTIAL, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE AND/OR SPECIAL LOSS AND/OR DAMAGE;
AND (b) LOSS AND/OR DEFERRAL OF PRODUCTION, LOSS OF PRODUCT, LOSS OF GOODWILL, LOSS OF
USE, LOSS OF REVENUE, PROFIT OR ANTICIPATED PROFIT, COST OF CAPITAL, IN EACH CASE WHETHER
DIRECT OR INDIRECT TO THE EXTENT THAT SUCH LOSS, DEFERRAL AND/OR COST ARE NOT INCLUDED IN
PARAGRAPH (a); AND (c) CLAIMS FOR SERVICE INTERRUPTION OR FAILURE TO SUPPLY, COSTS AND
EXPENSES INCURRED IN CONNECTION WITH LABOR OVERHEAD, TRANSPORTATION OR SUBSTITUTE
FACILITIES OR SUPPLY SOURCES, LABOR PERFORMED IN CONNECTION WITH THE REMOVAL AND
REPLACEMENT OF PRODUCTS WITHIN THE WELL OR ANY OTHER LOSS OR DAMAGE INCURRED AS A
RESULT OF OR OTHERWISE IN CONNECTION WITH INTERRUPTION OF SERVICE IN EACH CASE TO THE
EXTENT THAT SUCH CLAIM IS NOT INCLUDED IN PARAGRAPH (i) OR PARAGRAPH (ii).

NOTWITHSTANDING ANY PROVISION TO THE CONTRARY ELSEWHERE, IN NO CASE WILL THE SELLER BE
LIABLE FOR CONSEQUENTIAL LOSS AND BUYER SHALL BE LIABLE FOR AND SHALL SAVE, INDEMNIFY,
DEFEND AND HOLD HARMLESS THE SELLER GROUP FROM AND AGAINST ANY AND ALL CONSEQUENTIAL
LOSS EVEN IF CAUSED BY THE SELLER'S SOLE, JOINT, COMPARATIVE, CONTRIBUTORY OR CONCURRENT
NEGLIGENCE, FAULT, STRICT LIABILITY OR PRODUCT LIABILITY, AND REGARDLESS OF THE FORM OF
ACTION, WHETHER CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF WARRANTY, INDEMNITY,
STATUTE, STRICT LIABILITY OR OTHERWISE.

(ii) THE TOTAL LIABILITY OF SELLER ON ANY CLAIM WHETHER IN CONTRACT, TORT (INCLUDING
NEGLIGENCE WHETHER SOLE OR CONCURRENT) OR OTHERWISE ARISING OUT OF, CONNECTED WITH, OR
RESULTING FROM THE MANUFACTURE, SALE, DELIVERY, RESALE, REPAIR, REPLACEMENT OR USE OF ANY
PRODUCT, OR THE FURNISHING OF ANY SERVICE, OR THE PERFORMANCE OR NON-PERFORMANCE OF THE
CONTRACT SHALL NOT EXCEED THE PRICE RECEIVED BY THE SELLER AND ALLOCABLE TO THE PRODUCT
OR PART THEREOF, OR THE COST OF FURNISHING OF ANY SERVICE WORK WHICH GIVES RISE TO THE
CLAIM.
(iii) BUYER UNDERSTANDS AND AGREES THAT THE FOREGOING LIABILITY LIMITATIONS ARE ESSENTIAL
ELEMENTS OF THE CONTRACT AND THAT IN THE ABSENCE OF SUCH LIMITATIONS THE MATERIAL AND
ECONOMIC TERMS OF THIS CONTRACT WOULD BE SUBSTANTIALLY DIFFERENT.


9. INDEMNITIES
All exclusions and indemnities given under this Section 9 (save for those under Sections 9.1(c) and 9.2(c)) and Section 8.1, shall
apply irrespective of cause and notwithstanding the negligence or breach of duty (whether statutory or otherwise) of the
indemnified party or any other entity or party and shall apply irrespective of any claim in tort, under contract or otherwise at
law. For the purposes of Sections 9.1(c) and 9.2 (c), third party shall mean any party which is not a member of the Buyer
Group nor the Seller Group.

9.1. The Seller shall be responsible for and shall save, indemnify, defend and hold harmless the Buyer Group from and
against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of:
(a) subject to Section 9.2(d), loss of or damage to property (other than the Products after delivery pursuant to Section 5)
of the Seller Group whether owned, hired, leased or otherwise provided by the Seller Group arising from or relating to the
performance of the Contract;
(b) personal injury including death or disease to any person employed by the Seller Group arising from or relating to the
performance of the Contract; and
(c) subject to Section 9.3, personal injury including death or disease or loss of or damage to the property of any third
party to the extent that any such injury, loss or damage is caused by the negligence or breach of duty (whether
statutory or otherwise) of the Seller Group.
9.2 Buyer shall be responsible for and shall save, indemnify, defend and hold harmless Seller Group from and against all
claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of:
(a) loss of or damage to property of the Buyer Group, whether :-
(i) owned by the Buyer Group, or
(ii) hired, leased or otherwise provided by or for the Buyer Group (including the Products after delivery pursuant to
Section 5); and
(b) personal injury including death or disease to any person employed by the Buyer Group arising from relating to or in
connection with the performance or non-performance of the Contract;
(c) subject to any other express provisions of the Contract, personal injury including death or disease or loss of or damage to
the property of any third party to the extent that any such injury, loss or damage is caused by the negligence or breach of
duty (whether statutory or otherwise) of the Buyer Group; and
(d) at Sellers option, either the repair or replacement or reimbursement of the full cost of Sellers equipment, tools and/or
instruments which are lost or damaged down-hole in the Buyers well during the provision of Services or are lost or

Page 3 of 5




damaged due to abrasion or corrosion occasioned by well effluents unless such loss or damage is due to the sole negligence of
the Seller.

9.3 Notwithstanding Section 9.1, Buyer shall be liable for, and shall defend, indemnify and hold Seller Group harmless from
and against, any and all claims which arise out of the performance or non-performance of the Contract in relation to the
following, and whether or not resulting from, or contributed to by, the negligence of Seller Group; (i) loss of or damage to any
well or hole or any third party oil and gas production facilities; (ii) reservoir seepage or pollution originating underground or
from the property of the Buyer or third party howsoever arising; (iii) blow-out, fire, explosion, cratering of any well or
reservoir or any other uncontrolled well condition (including the costs to control a wild well and the removal of debris); (iv)
damage to or escape of product, or substance from any facility including any pipeline or other subsurface facility.

9.4 Notwithstanding anything to the contrary in the Contract, Buyer shall be responsible for and shall save, indemnify,
defend and hold harmless Seller Group from and against all claims, losses, damages, costs (including legal costs) expenses and
liabilities in respect of any acts or omissions of the employees or agents of the Seller Group in connection with the performance of
the Services (or any part of the Services), where, in accordance with the Contract, the employees of the Seller Group are
under the supervision, direction or control of the Buyer in respect of those Services or part of the Services.

10 NON-DELIVERY
The quantity of any consignment of Products as recorded by the Seller on dispatch from the Sellers place of business or other
designated location shall be conclusive evidence of the quantity received by Buyer on delivery unless Buyer can provide evidence
proving the contrary. Seller shall not be liable for non-delivery of Products (even if caused by Sellers negligence) unless Buyer gives
written notice to the Seller of the non-delivery within forty eight (48) hours of the date and time when the Product would in the
ordinary course of events have been received. Any liability of the Seller for non-delivery of the Products shall be limited to at Sellers sole
discretion either replacing the Products or issuing a credit note against any invoice raised for the Products.

11 PATENT INFRINGEMENT
If Buyer receives a claim or otherwise becomes aware that any Product or part thereof manufactured by Seller infringes or allegedly
infringes a patent or other intellectual property right, Buyer shall notify Seller immediately in writing and give Seller information,
assistance and exclusive authority to evaluate, defend and settle such claim or potential infringement. Seller shall then at its own expense
and option (a) settle such claim, or (b) procure for Buyer the right to use such Product, or (c) replace or modify it to avoid infringement,
or (d) remove it and refund the purchase price (including transportation and installation costs) less a reasonable amount for depreciation, or
(e) defend against such claim.
12 CANCELLATION AND CHANGES
The Buyer may not cancel or reschedule the delivery date of any Product and/or Services to be provided under the Contract without
the prior written consent of the Seller. In the event that the Seller provides such consent, any such cancellation or rescheduling of
Product and/or Services by Buyer will result in a charge to Buyer to be determined by the Seller. All specially designed or modified
Products cancelled after commencement of manufacture will be subject to a cancellation charge which will include all costs and a
reasonable margin for time employed, as determined by Seller. Cancellation charges for accessories and components sourced from
third parties will be charged at full price. Seller shall, at its sole discretion, adjust the price or delivery dates or make such other
amendments as may be required as a result of any change order agreed to be issued by the Buyer and Seller. No amendment to a
purchase order or Order Acknowledgement or change order shall be valid unless agreed in writing by the Seller (at its sole discretion).

13 WAIVER
Any waiver by Seller of any breach or default by Buyer of any of the Buyers obligations under the Contract, or any failure by Seller to
enforce any rights arising under the Contract shall not be construed as a waiver of any other or subsequent breach or default by Buyer or
of Sellers right to enforce its rights arising hereunder in any circumstances. In the event of any default by Buyer, Seller may decline to
make further shipments. If Seller elects to continue to make deliveries, Sellers action shall not constitute a waiver of any such default or
affect Sellers remedies for any such default.
14 ENTIRE AGREEMENT:
The Order Acknowledgement, any Special Conditions and these Standard Terms and Conditions constitute the entire agreement
between the parties relating to the sale of the Products and/or Services and supersedes all previous communications, representations,
or agreements, either oral or written, with respect to the subject matter hereof. No prior representations or statements relating to the
sale of the Products and/or Services made by any Seller representative, which are not stated herein, shall be binding on Seller.

15 EXPORT CONTROL
Buyer agrees that unless prior authorization is obtained from the U.S. Department of Commerce, neither Buyer nor its subsidiaries shall
export, re-export, or release, directly or indirectly, any Product received from Seller to any destination or country to which the export, re-
export or release of the technology or Product is prohibited by the Export Administration Regulations of the U.S. Department of
Commerce ("EAR"), or prohibited by US or applicable non-US laws.

Buyer will be responsible for obtaining any necessary export license or other documentation prior to the exportation or re-exportation
of any Product acquired from Seller under the Contract. Further, Buyer shall give notice of the need to comply with such laws and
regulations to any person, firm or entity which it has reason to believe is obtaining any such Product from Buyer with the intention of
exportation. Each party shall secure, at its own expense, such licenses and export and import documents as are necessary for each
respective party to fulfill its obligations under the Contract. If approvals cannot be obtained, Seller may terminate, cancel or otherwise
Page 4 of 5




be excused from performing any obligations it may have under the Contract. Any export classification made by Seller shall be for
Seller's internal use only and shall not be construed as a representation or warranty regarding the proper export classification for such
Product or whether an export license or other documentation is required for the exportation of such Product. This Section 15 shall
survive termination of the Contract.

16 BUSINESS ETHICS
Neither Seller nor Buyer shall make any payment or take any action that could be construed to be the payment of money or other thing
of value to any government official, political party, or political party candidate for the purpose of influencing any act or inducing any
government official to use his or its influence to assist in obtaining or retaining business in any country in a manner which is illegal or
which would subject the Seller to civil or criminal penalties, or which is inconsistent with Sellers Business Ethics Policy.

17 ASSIGNMENT
The Seller may assign this Contract or any part of it to any person, firm or company. The Buyer shall not be entitled to assign the
Contract or any part of it without the prior written consent of the Seller.

18 ARBITRATION
The parties agree that any and all disputes or controversies that may arise between the parties arising out of or related to this Contract shall be
determined by binding arbitration. Any such arbitration shall be determined before the American Arbitration Association (AAA) in
accordance with AAA rules then in effect, with each party nominating one arbiter and the two arbiters nominating a third, and that any
arbitration proceedings shall be held in Oklahoma City, Oklahoma. Judgment upon arbitration awards may be entered in any court, state or
federal, having jurisdiction.

19 GOVERNING LAW
This Contract shall be governed and construed in accordance with the laws of the State of Oklahoma, without giving effect to any
conflicts of laws principles.
20 MISCELLANEOUS
All samples, drawings, descriptive matter, specifications and advertising issued by the Seller and any descriptions or illustrations
contained in the Sellers catalogues or brochures are issued or published for the sole purpose of giving an approximate idea of the
Products and/or Services described in them. They shall not form part of the Contract.
The Buyer shall at its own expense secure any permits or any other authorizations (including but not limited to work permits and visas for
employees of the Seller) which may be required to permit the Seller to perform the Services. The Buyer agrees to indemnify the Seller
against any costs, claims, actions, demands or expenses incurred or suffered in connection with the Buyers failure to obtain any permits or
authorizations required to perform the Services.

If any provision of the Contract is found by any court, tribunal or administrative body of competent jurisdiction to be wholly or partly
illegal, invalid, void, voidable, unenforceable or unreasonable it shall to the extent of such illegality, invalidity, voidness, voidability,
unenforceability or unreasonableness be deemed severable and the remaining provisions of the Contract and the remainder of such
provision shall continue in full force.
These Standard Terms and Conditions are subject to change without prior written notice at any time and from time to time at the
Sellers sole discretion. All communications between the parties about the Contract shall be in writing and delivered by hand or sent
by fax to its registered office or such other address as shall be notified to the other party. Communications shall be deemed to have
been received if delivered by hand, on the day of delivery or if sent by fax on a business day at the time of transmission and otherwise
on the next working day.























Page 5 of 5




WOOD GROUP ESP (CANADA) LTD.
STANDARD TERMS AND CONDITIONS OF SALE

1. INTERPRETATION
In these Standard Terms and Conditions:
Buyer means the person, firm or company with whom the Contract is made;
Buyer Group means the Buyer, its co-venturers, its and their respective affiliates and agents and its and their respective directors,
officers and employees;
Contract means the contract between the Seller and the Buyer for the sale and purchase of the Products and/or Services,
incorporating these Standard Terms and Conditions;
Order Acknowledgement means the written acceptance by Seller of Buyers purchase order or specification which shall
incorporate these Standard terms and Conditions which forms the Contract;
Product(s) means any products or parts agreed in the Contract to be supplied to the Buyer by the Seller;
Seller means the selling entity identified in the Order Acknowledgement, or if none, the quotation;
Seller Group means the Seller, its sub-suppliers, its and their respective affiliates and agents, its and their respective directors,
officers and employees;
Services means any services agreed in the Contract to be supplied to the Buyer by the Seller;
Special Conditions means those Special Terms and Conditions set out in the Order Acknowledgement or other document issued by
the Seller.

2. APPLICABILITY
2.1 Subject to any variation under Section 2.3, the Contract shall be on these Standard Terms and Conditions to the exclusion of all other
terms and conditions (including any terms and conditions which the Buyer purports to apply under any purchase order, confirmation of
order, specification or other document).
2.2 No terms or conditions endorsed on, delivered with or contained in the Buyers purchase order, confirmation of order, specification or
other documents shall form part of the Contract simply as a result of such document being referred to in the Contract.
2.3 These Standard Terms and Conditions apply to all the Sellers sales and any variations to these Standard Terms and Conditions and
any representations about the Products shall have no effect unless expressly agreed in writing and signed by an Authorized Signatory of the
Seller. The Buyer acknowledges that it has not relied on any statement, promise or representation made or given by or on behalf of the
Seller which is not set out in the Contract.
2.4 Each order or acceptance of a quotation for Products by the Buyer from the Seller shall be deemed to be an offer by the Buyer to buy
Products subject to these Standard Terms and Conditions.
2.5 No order placed by the Buyer shall be deemed to be accepted by the Seller until an Order Acknowledgement is issued by the Seller,
or (if earlier), the Seller delivers the Products or Services to the Buyer.
2.6 The Buyer shall ensure that the terms of its order and any applicable specification are complete and accurate.
2.7 Any quotation is given on the basis that no Contract shall come into existence until the Seller dispatches an Order Acknowledgement
or delivers the Products or Services to the Buyer. Any quotation is valid for a period of 30 days only from its date, provided that the
Seller has not previously withdrawn it. All quotations of Seller are subject to change at any time.

3. PRICES
All prices are subject to change without notice. Prices do not include packing and preparation of export shipment, inland or ocean
freight, loading, unloading, carriage, insurance or forwarding fees, taxes, or duties of any kind or other similar charges applicable to the
Products, Services and/or the Contract. Buyer agrees to pay such charges incurred by Seller on Buyers behalf together with additional
handling charges upon receipt of Sellers invoice for the same.

4. TERMS OF PAYMENT
Unless Seller and Buyer otherwise agree in writing to payment terms other than those specified herein, payment shall be made in U.S.
dollars in accordance with remittance instructions furnished by Seller.
(i) All payments shall be made within thirty (30) days after date of Sellers invoice.
(ii) Time for payment shall be of the essence.
(iii) Seller may suspend credit to Buyer and may withhold shipment of Products ordered, suspend or cancel performance under
these Standard Terms and Conditions if in its sole judgment the financial condition of the Buyer warrants such action.
Suspension of performance may result in rescheduling delays.
(iv) Prices do not include applicable taxes or duties. Buyer is solely responsible for paying all applicable taxes and duties. Seller
will add taxes to the price where required by applicable law, and Buyer will pay all such taxes unless Buyer provides Seller
with a duly executed tax exemption certificate in a form satisfactory to the Seller. If Buyer is required by applicable law to
withhold any amount of tax from its payment to Seller, Buyer shall promptly pay such amount to the appropriate tax
authority and take all reasonable steps to minimize such withholding tax. Buyer shall take all steps required to promptly obtain
and deliver to Seller the appropriate certification of any such withholding in a form satisfactory to the Seller.
(v) The Buyer shall make all payments due under the Contract in full without any deduction whether by way of set-off,
counterclaim, discount, abatement or otherwise.
(vi) All payments payable to the Seller under the Contract shall become due immediately on its termination despite any other
provision.


Page 1 of 5




(vii) If the Buyer fails to pay the Seller any sum due pursuant to the Contract, the Buyer shall be liable to pay interest to the Seller
on such sum from the due date for payment at the rate of eighteen percent (18%) per annum or at the highest rate allowed by
law.
5. SHIPPING, DELIVERY, TITLE & RISK OF LOSS
Products shall be delivered EXW (at location named by the Seller) (Incoterms 2000). Risk for loss or damage shall pass to Buyer upon
Sellers delivery to Buyer. Title shall pass to the Buyer upon receipt of payment in cleared funds by the Seller of amounts due in respect
of the Contract.

Seller may deliver the Products in installments. Each installment shall be a separate Contract and no cancellation or termination of any
one Contract relating to an installment shall entitle the Buyer to repudiate or cancel any other Contract or installment. Delivery dates
are intended to be an estimate and time and date for delivery shall not be made of the essence by notice or otherwise and are dependent
on prompt receipt by Seller of all information and assistance required or requested by Seller to permit Seller to carry out its obligations
under the Contract. Seller shall not be liable for any damage, losses or expenses incurred by Buyer if Seller fails to meet the estimated
delivery dates.

In the event that Products are not collected by Buyer on actual date of delivery, Seller may (at its sole discretion) place Products in
storage at the sole cost, expense and risk of the Buyer.

6. FORCE MAJEURE
Seller reserves the right to defer the date of delivery of Products and/or the date of performance of Services, to cancel the Contract, or
reduce the volume of the Products and/or amend the scope of the Services ordered by Buyer (without liability to Buyer) if it is
prevented from or delayed in the carrying out of its business due to circumstances beyond its reasonable control, including but not
limited to, natural disasters, forces of nature, earthquake, tidal wave, landslide, flood, lightening, hurricane, typhoon, storm or other
weather condition not included in normal planning, epidemic and plague; changes in law or regulations, governmental actions; acts of
civil or military authority; fire; explosion; lock-outs, strikes and/or labor disputes (whether or not relating to either partys workforce);
civil commotion; protests; war; national emergency; riot; civil insurrection; acts of terrorism; restraints or delays in transportation;
restraints or delays in manufacturing and inability of Seller to obtain adequate or suitable supplies from usual sources, or acts of Buyer
resulting in commercial impracticality. In the event of any such delay, the date of delivery and/or performance shall be deferred for a
period equal to the time lost by reason of the delay.

7. WARRANTY
Seller warrants that Products manufactured by Seller, when properly stored, commissioned, installed, used and maintained, and
Services performed by the Seller, shall be free from defects in material and workmanship. Sellers obligation under this warranty shall
be limited to replacing or repairing the part or parts or, the Products, at Sellers option, which prove to be defective in material or
workmanship within twelve (12) months from the date of installation or eighteen (18) months from the date of delivery, whichever
shall occur first, or reperforming Services within twelve (12) months of the Services being supplied (WARRANTY PERIOD),
provided the Buyer gives Seller prompt notice of any defect and provides proof in a form and substance satisfactory to the Seller
(acting in its sole discretion) including all relevant data and documentation needed to assess well and equipment performance and
operations. Any defective part or parts must be returned freight prepaid by Buyer to an authorized service center designated by Seller
for inspection. Seller will deliver any replacements for defective Products to Buyer prepaid to the delivery destination provided by the
original order. Products returned to the Seller for which Seller provides replacement under this warranty shall become the property of
the Seller.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, WHETHER ORAL,
WRITTEN, EXPRESSED, IMPLIED OR STATUTORY, AND SELLER MAKES NO WARRANTY AS TO FITNESS FOR
PURPOSE OR MERCHANTABILITY. SELLERS WARRANTY OBLIGATIONS AND BUYERS REMEDIES ARE SOLELY AND
EXCLUSIVELY AS STATED HEREIN.

THE WARRANTY PERIOD SHALL NOT BE EXTENDED FOR REPAIRED OR REPLACED PARTS OR PRODUCTS OR
REPERFORMED SERVICES. SUCH PARTS OR PRODUCTS OR SERVICES SHALL REMAIN UNDER WARRANTY ONLY FOR
THE UNEXPIRED PORTION OF THE WARRANTY PERIOD. SELLERS SOLE LIABILITY SHALL BE AT ITS OPTION TO
REPAIR OR REPLACE PARTS OR PRODUCTS OR REPERFORM SERVICES UNDER THIS CONDITION. SELLER MAY IN ITS
SOLE DISCRETION CREDIT BUYER'S ACCOUNT FOR A PORTION OF SUCH PARTS OR PRODUCTS AND/OR SERVICES
DETERMINED BY SELLER TO BE DEFECTIVE
The foregoing warranty does not apply to: (a) defect caused or contributed to by abrasive materials, corrosion due to aggressive fluids,
lightening, improper voltage supply, mishandling or misapplication; (b) Products or parts which are normally consumed in operation,
or have a normal life inherently shorter than the WARRANTY PERIOD; (c) alterations or repairs carried out without prior written
approval of the Seller, or using equipment and accessories for a purpose other than that for which such equipment and accessories are
intended; (d) installations carried out by the Buyer unless Buyers engineers have been appropriately trained and certified by Seller;
(e) installations in which Buyer has not used the application engineering practices for the Products as approved by Supplier; (f)
defective Products or Services where Buyer makes further use of the Products after the earlier of the Buyers awareness of the defect or the
time when the Buyer ought to have become aware of such defect; (g) defects arising from or in connection with information, drawings,
chart interpretations, technical specifications or instructions provided by the Buyer to the Seller.


Page 2 of 5




8. LIMITATION OF LIABILITY
(i) FOR THE PURPOSE OF THIS SECTION 8(i), THE EXPRESSION "CONSEQUENTIAL LOSS" SHALL MEAN (IN EACH
CASE WHETHER OR NOT FORESEEABLE AT THE DATE OF THE CONTRACT): (a) ANY AND ALL
CONSEQUENTIAL, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE AND/OR SPECIAL LOSS AND/OR DAMAGE;
AND (b) LOSS AND/OR DEFERRAL OF PRODUCTION, LOSS OF PRODUCT, LOSS OF GOODWILL, LOSS OF
USE, LOSS OF REVENUE, PROFIT OR ANTICIPATED PROFIT, COST OF CAPITAL, IN EACH CASE WHETHER
DIRECT OR INDIRECT TO THE EXTENT THAT SUCH LOSS, DEFERRAL AND/OR COST ARE NOT INCLUDED IN
PARAGRAPH (a); AND (c) CLAIMS FOR SERVICE INTERRUPTION OR FAILURE TO SUPPLY, COSTS AND
EXPENSES INCURRED IN CONNECTION WITH LABOR OVERHEAD, TRANSPORTATION OR SUBSTITUTE
FACILITIES OR SUPPLY SOURCES, LABOR PERFORMED IN CONNECTION WITH THE REMOVAL AND
REPLACEMENT OF PRODUCTS WITHIN THE WELL OR ANY OTHER LOSS OR DAMAGE INCURRED AS A
RESULT OF OR OTHERWISE IN CONNECTION WITH INTERRUPTION OF SERVICE IN EACH CASE TO THE
EXTENT THAT SUCH CLAIM IS NOT INCLUDED IN PARAGRAPH (i) OR PARAGRAPH (ii).

NOTWITHSTANDING ANY PROVISION TO THE CONTRARY ELSEWHERE, IN NO CASE WILL THE SELLER BE
LIABLE FOR CONSEQUENTIAL LOSS AND BUYER SHALL BE LIABLE FOR AND SHALL SAVE, INDEMNIFY,
DEFEND AND HOLD HARMLESS THE SELLER GROUP FROM AND AGAINST ANY AND ALL CONSEQUENTIAL
LOSS EVEN IF CAUSED BY THE SELLER'S SOLE, JOINT, COMPARATIVE, CONTRIBUTORY OR CONCURRENT
NEGLIGENCE, FAULT, STRICT LIABILITY OR PRODUCT LIABILITY, AND REGARDLESS OF THE FORM OF
ACTION, WHETHER CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF WARRANTY, INDEMNITY,
STATUTE, STRICT LIABILITY OR OTHERWISE.

(ii) THE TOTAL LIABILITY OF SELLER ON ANY CLAIM WHETHER IN CONTRACT, TORT (INCLUDING
NEGLIGENCE WHETHER SOLE OR CONCURRENT) OR OTHERWISE ARISING OUT OF, CONNECTED WITH, OR
RESULTING FROM THE MANUFACTURE, SALE, DELIVERY, RESALE, REPAIR, REPLACEMENT OR USE OF ANY
PRODUCT, OR THE FURNISHING OF ANY SERVICE, OR THE PERFORMANCE OR NON-PERFORMANCE OF THE
CONTRACT SHALL NOT EXCEED THE PRICE RECEIVED BY THE SELLER AND ALLOCABLE TO THE PRODUCT
OR PART THEREOF, OR THE COST OF FURNISHING OF ANY SERVICE WORK WHICH GIVES RISE TO THE
CLAIM.
(iii) BUYER UNDERSTANDS AND AGREES THAT THE FOREGOING LIABILITY LIMITATIONS ARE ESSENTIAL
ELEMENTS OF THE CONTRACT AND THAT IN THE ABSENCE OF SUCH LIMITATIONS THE MATERIAL AND
ECONOMIC TERMS OF THIS CONTRACT WOULD BE SUBSTANTIALLY DIFFERENT.


9. INDEMNITIES
All exclusions and indemnities given under this Section 9 (save for those under Sections 9.1(c) and 9.2(c)) and Section 8.1, shall
apply irrespective of cause and notwithstanding the negligence or breach of duty (whether statutory or otherwise) of the
indemnified party or any other entity or party and shall apply irrespective of any claim in tort, under contract or otherwise at
law. For the purposes of Sections 9.1(c) and 9.2 (c), third party shall mean any party which is not a member of the Buyer
Group nor the Seller Group.

9.1. The Seller shall be responsible for and shall save, indemnify, defend and hold harmless the Buyer Group from and
against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of:
(a) subject to Section 9.2(d), loss of or damage to property (other than the Products after delivery pursuant to Section 5)
of the Seller Group whether owned, hired, leased or otherwise provided by the Seller Group arising from or relating to the
performance of the Contract;
(b) personal injury including death or disease to any person employed by the Seller Group arising from or relating to the
performance of the Contract; and
(c) subject to Section 9.3, personal injury including death or disease or loss of or damage to the property of any third
party to the extent that any such injury, loss or damage is caused by the negligence or breach of duty (whether
statutory or otherwise) of the Seller Group.
9.2 Buyer shall be responsible for and shall save, indemnify, defend and hold harmless Seller Group from and against all
claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of:
(a) loss of or damage to property of the Buyer Group, whether :-
(i) owned by the Buyer Group, or
(ii) hired, leased or otherwise provided by or for the Buyer Group (including the Products after delivery pursuant to
Section 5); and
(b) personal injury including death or disease to any person employed by the Buyer Group arising from relating to or in
connection with the performance or non-performance of the Contract;
(c) subject to any other express provisions of the Contract, personal injury including death or disease or loss of or damage to
the property of any third party to the extent that any such injury, loss or damage is caused by the negligence or breach of
duty (whether statutory or otherwise) of the Buyer Group; and
(d) at Sellers option, either the repair or replacement or reimbursement of the full cost of Sellers equipment, tools and/or
instruments which are lost or damaged down-hole in the Buyers well during the provision of Services or are lost or

Page 3 of 5




damaged due to abrasion or corrosion occasioned by well effluents unless such loss or damage is due to the sole negligence of
the Seller.

9.3 Notwithstanding Section 9.1, Buyer shall be liable for, and shall defend, indemnify and hold Seller Group harmless from
and against, any and all claims which arise out of the performance or non-performance of the Contract in relation to the
following, and whether or not resulting from, or contributed to by, the negligence of Seller Group; (i) loss of or damage to any
well or hole or any third party oil and gas production facilities; (ii) reservoir seepage or pollution originating underground or
from the property of the Buyer or third party howsoever arising; (iii) blow-out, fire, explosion, cratering of any well or
reservoir or any other uncontrolled well condition (including the costs to control a wild well and the removal of debris); (iv)
damage to or escape of product, or substance from any facility including any pipeline or other subsurface facility.

9.4 Notwithstanding anything to the contrary in the Contract, Buyer shall be responsible for and shall save, indemnify,
defend and hold harmless Seller Group from and against all claims, losses, damages, costs (including legal costs) expenses and
liabilities in respect of any acts or omissions of the employees or agents of the Seller Group in connection with the performance of
the Services (or any part of the Services), where, in accordance with the Contract, the employees of the Seller Group are
under the supervision, direction or control of the Buyer in respect of those Services or part of the Services.

10 NON-DELIVERY
The quantity of any consignment of Products as recorded by the Seller on dispatch from the Sellers place of business or other
designated location shall be conclusive evidence of the quantity received by Buyer on delivery unless Buyer can provide evidence
proving the contrary. Seller shall not be liable for non-delivery of Products (even if caused by Sellers negligence) unless Buyer gives
written notice to the Seller of the non-delivery within forty eight (48) hours of the date and time when the Product would in the
ordinary course of events have been received. Any liability of the Seller for non-delivery of the Products shall be limited to at Sellers sole
discretion either replacing the Products or issuing a credit note against any invoice raised for the Products.

11 PATENT INFRINGEMENT
If Buyer receives a claim or otherwise becomes aware that any Product or part thereof manufactured by Seller infringes or allegedly
infringes a patent or other intellectual property right, Buyer shall notify Seller immediately in writing and give Seller information,
assistance and exclusive authority to evaluate, defend and settle such claim or potential infringement. Seller shall then at its own expense
and option (a) settle such claim, or (b) procure for Buyer the right to use such Product, or (c) replace or modify it to avoid infringement,
or (d) remove it and refund the purchase price (including transportation and installation costs) less a reasonable amount for depreciation, or
(e) defend against such claim.
12 CANCELLATION AND CHANGES
The Buyer may not cancel or reschedule the delivery date of any Product and/or Services to be provided under the Contract without
the prior written consent of the Seller. In the event that the Seller provides such consent, any such cancellation or rescheduling of
Product and/or Services by Buyer will result in a charge to Buyer to be determined by the Seller. All specially designed or modified
Products cancelled after commencement of manufacture will be subject to a cancellation charge which will include all costs and a
reasonable margin for time employed, as determined by Seller. Cancellation charges for accessories and components sourced from
third parties will be charged at full price. Seller shall, at its sole discretion, adjust the price or delivery dates or make such other
amendments as may be required as a result of any change order agreed to be issued by the Buyer and Seller. No amendment to a
purchase order or Order Acknowledgement or change order shall be valid unless agreed in writing by the Seller (at its sole discretion).

13 WAIVER
Any waiver by Seller of any breach or default by Buyer of any of the Buyers obligations under the Contract, or any failure by Seller to
enforce any rights arising under the Contract shall not be construed as a waiver of any other or subsequent breach or default by Buyer or
of Sellers right to enforce its rights arising hereunder in any circumstances. In the event of any default by Buyer, Seller may decline to
make further shipments. If Seller elects to continue to make deliveries, Sellers action shall not constitute a waiver of any such default or
affect Sellers remedies for any such default.
14 ENTIRE AGREEMENT:
The Order Acknowledgement, any Special Conditions and these Standard Terms and Conditions constitute the entire agreement
between the parties relating to the sale of the Products and/or Services and supersedes all previous communications, representations,
or agreements, either oral or written, with respect to the subject matter hereof. No prior representations or statements relating to the
sale of the Products and/or Services made by any Seller representative, which are not stated herein, shall be binding on Seller.

15 EXPORT CONTROL
Buyer agrees that unless prior authorization is obtained from the U.S. Department of Commerce, neither Buyer nor its subsidiaries shall
export, re-export, or release, directly or indirectly, any Product received from Seller to any destination or country to which the export, re-
export or release of the technology or Product is prohibited by the Export Administration Regulations of the U.S. Department of
Commerce ("EAR"), or prohibited by US or applicable non-US laws.

Buyer will be responsible for obtaining any necessary export license or other documentation prior to the exportation or re-exportation
of any Product acquired from Seller under the Contract. Further, Buyer shall give notice of the need to comply with such laws and
regulations to any person, firm or entity which it has reason to believe is obtaining any such Product from Buyer with the intention of
exportation. Each party shall secure, at its own expense, such licenses and export and import documents as are necessary for each
respective party to fulfill its obligations under the Contract. If approvals cannot be obtained, Seller may terminate, cancel or otherwise
Page 4 of 5




be excused from performing any obligations it may have under the Contract. Any export classification made by Seller shall be for
Seller's internal use only and shall not be construed as a representation or warranty regarding the proper export classification for such
Product or whether an export license or other documentation is required for the exportation of such Product. This Section 15 shall
survive termination of the Contract.

16 BUSINESS ETHICS
Neither Seller nor Buyer shall make any payment or take any action that could be construed to be the payment of money or other thing
of value to any government official, political party, or political party candidate for the purpose of influencing any act or inducing any
government official to use his or its influence to assist in obtaining or retaining business in any country in a manner which is illegal or
which would subject the Seller to civil or criminal penalties, or which is inconsistent with Sellers Business Ethics Policy.

17 ASSIGNMENT
The Seller may assign this Contract or any part of it to any person, firm or company. The Buyer shall not be entitled to assign the
Contract or any part of it without the prior written consent of the Seller.

18 ARBITRATION
The parties agree that any and all disputes or controversies that may arise between the parties arising out of or related to this Contract shall be
determined by binding arbitration. Any such arbitration shall be determined before the American Arbitration Association (AAA) in
accordance with AAA rules then in effect, with each party nominating one arbiter and the two arbiters nominating a third, and that any
arbitration proceedings shall be held in Oklahoma City, Oklahoma, USA. Judgment upon arbitration awards may be entered in any court,
state or federal, having jurisdiction.

19 GOVERNING LAW
This Contract shall be governed and construed in accordance with the laws of the State of Oklahoma, USA, without giving effect to
any conflicts of laws principles.
20 MISCELLANEOUS
All samples, drawings, descriptive matter, specifications and advertising issued by the Seller and any descriptions or illustrations
contained in the Sellers catalogues or brochures are issued or published for the sole purpose of giving an approximate idea of the
Products and/or Services described in them. They shall not form part of the Contract.
The Buyer shall at its own expense secure any permits or any other authorizations (including but not limited to work permits and visas for
employees of the Seller) which may be required to permit the Seller to perform the Services. The Buyer agrees to indemnify the Seller
against any costs, claims, actions, demands or expenses incurred or suffered in connection with the Buyers failure to obtain any permits or
authorizations required to perform the Services.

If any provision of the Contract is found by any court, tribunal or administrative body of competent jurisdiction to be wholly or partly
illegal, invalid, void, voidable, unenforceable or unreasonable it shall to the extent of such illegality, invalidity, voidness, voidability,
unenforceability or unreasonableness be deemed severable and the remaining provisions of the Contract and the remainder of such
provision shall continue in full force.
These Standard Terms and Conditions are subject to change without prior written notice at any time and from time to time at the
Sellers sole discretion. All communications between the parties about the Contract shall be in writing and delivered by hand or sent
by fax to its registered office or such other address as shall be notified to the other party. Communications shall be deemed to have
been received if delivered by hand, on the day of delivery or if sent by fax on a business day at the time of transmission and otherwise
on the next working day.























Page 5 of 5





WOOD GROUP ESP
TRMINOS Y CONDICIONES DE VENTA ESTNDAR

1. INTERPRETACIN
En estos Trminos y Condiciones de Venta Estndar:
Comprador significa la persona, firma o empresa con quien se celebra el Contrato;
Grupo del Comprador significa el Comprador, sus accionistas, sus empresas asociadas, sus
afiliadas y agentes y sus respectivos directores, empleados de alto rango y empleados en general;
Contrato significa el contrato celebrado entre el Vendedor y el Comprador para la venta y compra
de los Productos y/o Servicios, incorporando estos Trminos y Condiciones Estndar;
Acuse de Recibo de la Orden significa la aceptacin por escrito por parte del Vendedor de la orden
de compra o especificaciones del Comprador que incorporarn estos Trminos y Condiciones Estndar
que constituyen el Contrato;
Producto(s) significa los productos o partes cuyo suministro por el Vendedor al Comprador se
acuerda en el Contrato;
Vendedor significa la entidad vendedora identificada en el Acuse de Recibo de la Orden, o de no
haber uno, en la cotizacin;
Grupo del Vendedor significa el Vendedor, sus accionistas, sus sub-proveedores, y sus respectivas
afiliadas y agentes y sus respectivos directores, altos empleados y empleados en general;
Servicios significa los servicios cuyo suministro por el Vendedor al Comprador se acuerda en el
Contrato;
Condiciones especiales significa los Trminos y Condiciones Especiales establecidos en el Acuse de
Recibo de la Orden u otro documento expedido por el Vendedor.

2. APLICABILIDAD
2.1. Sujeto a cualquier variacin bajo la condicin 2.3, el Contrato consistir de estos Trminos y
Condiciones Estndar con exclusin de cualquier otros trminos y condiciones (incluyendo los
trminos y condiciones que el Comprador tenga por intencin aplicar bajo cualquier orden de compra,
confirmacin de la orden, especificaciones u otro documento).
2.2. Los trminos y condiciones aprobados, entregados o contenidos, respectivamente, en la orden de
compra del Comprador, confirmacin de la orden, especificaciones u otros documentos no formarn
parte del Contrato simplemente por el hecho de que dichos documentos sean referidos en el Contrato.
2.3. Estos Trminos y Condiciones Estndar se aplicarn a todas las ventas del Vendedor y los cambios de
dichos Trminos y Condiciones Estndar y las representaciones hechas acerca de los Productos no
tendrn ningn efecto, salvo que sean acordados en forma expresa por escrito y lleven la firma de un
Signatario autorizado por el Vendedor. El Comprador reconoce que no ha actuado en base a
declaracin, promesa o representacin alguna hecha o manifestada por el Vendedor, o en nombre del
Vendedor, que no figure en el Contrato.
2.4. Cada orden o aceptacin de una cotizacin de Productos del Vendedor por parte del Comprador se
considerar como una oferta del Comprador para la compra de Productos, sujeta a estos Trminos y
Condiciones Estndar.
2.5. Ninguna orden colocada por el Comprador se considerar aceptada por el Vendedor hasta que se
expida el Acuse de Recibo de la Orden por el Vendedor, o, hasta que el Vendedor entregue los
Productos o suministre los Servicios al Comprador, lo que ocurra primero.
2.6. El Comprador se asegurar de que los trminos de su orden y las especificaciones aplicables se
formulen en forma completa y precisa.
2.7. La cotizacin se hace sobre la base de que el Contrato no entrar en vigencia hasta que el Vendedor
expida el Acuse de Recibo de la Orden o entregue los Productos o suministre los Servicios al
Comprador. La cotizacin es vlida por un perodo de 30 das contados desde la fecha de la misma,
siempre que el Vendedor no la haya retirado anteriormente. Todas las cotizaciones del Vendedor estn
sujetas a cambio en cualquier momento.

3. PRECIOS


Pgina 1 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






Todos los precios estn sujetos a cambio sin aviso. Los precios no incluyen el empaque y preparacin del
embarque de exportacin, flete terrestre o martimo, carga, descarga, transporte, seguro o comisin del
agente de expedicin de la mercadera, impuestos o derechos de aduana de cualquier clase u otros cobros
similares aplicables a los Productos, Servicios y/o el Contrato. El Comprador acuerda pagar los costos
incurridos por el Vendedor en nombre del Comprador, junto con los gastos de manipulacin
adicionales una vez que reciba la factura del Vendedor por los mismos.

4. TRMINOS DE PAGO
Salvo que el Vendedor y el Comprador acuerden por escrito trminos de pago distintos a los
estipulados en el presente el pago se har en dlares estadounidenses, conforme con las instrucciones de
remesa proporcionadas por el Vendedor.
(i) El pago se har mediante carta de crdito a ser abierta por el Comprador, a su costo,
incluyendo los gastos de confirmacin. Todas las cartas de crdito sern en favor del
Vendedor, y en una forma que sea aceptable para el Vendedor, debern ser por las cantidades
que sean suficientes y por los perodos que sean necesarios para cumplir con todas las
obligaciones de pago, sern irrevocables y se emitirn o confirmarn por un banco que sea
satisfactorio para el Vendedor, dentro de los 30 das de la expedicin del Acuse de Recibo de
la Orden.
(ii) Todos los pagos se harn dentro de los treinta (30) das siguientes a la fecha de la factura del
Vendedor.
(iii) El plazo para el pago es de la esencia del contrato.
(iv) El Vendedor puede suspender el crdito al Comprador y puede retener el embarque de los
Productos ordenados, suspender o cancelar su propio cumplimiento bajo estos Trminos y
Condiciones Estndar si, a su juicio exclusivo, la condicin financiera del Comprador justifica
dicha accin. La suspensin de su propio cumplimiento puede resultar en la reprogramacin de
los plazos por las demoras.
(v) Los precios no incluyen los impuestos o derechos de aduana aplicables. El Comprador es el
nico responsable del pago de todos los impuestos y derechos de aduana aplicables. El
Vendedor agregar impuestos al precio cuando as lo requiera la ley aplicable, y el Comprador
pagar dichos impuestos en su totalidad, salvo que el Comprador le presente al Vendedor un
certificado de exencin tributaria debidamente otorgado, en una forma que sea satisfactoria
para el Vendedor. Si bajo la ley aplicable se exige que el Comprador retenga los impuestos
correspondientes al pago hecho al Vendedor, el Comprador remitir en forma inmediata a la
autoridad fiscal correspondiente el monto de dicha retencin de impuestos y adoptar todas
las medidas que sean razonables para minimizar dicha retencin de impuestos. El Comprador
adoptar todas las medidas requeridas para obtener y entregar en forma inmediata al
Vendedor la certificacin, correspondiente a dicha retencin en una forma que sea
satisfactoria para el Vendedor.
(vi) El Comprador abonar todos los pagos vencidos bajo el Contrato en forma total sin ninguna
deduccin, ya sea sta en la forma de un mecanismo de compensacin, reconvencin,
descuento, rebaja o de otro modo.
(vii) Todos los pagos pagaderos al Vendedor bajo el Contrato vencern en forma inmediata a la
terminacin del Contrato salvo cualquier estipulacin en contrario.
(viii) Si el Comprador no cumple con pagar al Vendedor una suma vencida segn el Contrato, el
Comprador ser responsable del pago de intereses al Vendedor que se devenguen sobre dicha
suma desde la fecha de pago, a razn de una tasa de inters anual de 3% por encima del tipo
de inters bancario del mercado de Londres (LIBOR) del Dlar Estadounidense de 12 meses,
intereses que se devengarn en forma diaria hasta que se haga el pago, sea antes o despus de
una sentencia. En caso que la aplicacin de dicha tasa de inters no sea procedente de acuerdo
a la ley aplicable al lugar de ejecucin del Contrato, se aplicar la tasa mxima que dicha ley
permita.

5. EMBARQUE, ENTREGA, TTULO Y RIESGO DE PRDIDA
Los trminos de entrega de los Productos son EXW (en el lugar designado por el Vendedor), segn los
Trminos de Comercio Internacional (Incoterms 2000). El riesgo de prdida o daos pasar al
Comprador con la entrega realizada por el Vendedor al Comprador. El ttulo de los Productos pasar al

Pgina 2 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






Comprador una vez que el Vendedor reciba el pago de fondos autorizados por las cantidades
adeudadas con respecto al Contrato.

El Vendedor puede hacer la entrega de los Productos mediante entregas parciales. Cada entrega parcial
constituir un Contrato separado y ninguna cancelacin o terminacin de un Contrato relacionado con
una entrega parcial dar lugar al Comprador a rechazar o cancelar cualquier otro Contrato o entrega
parcial. Se entiende que las fechas de entrega son estimadas y el tiempo y fecha de entrega no sern de
la esencia del contrato en virtud de un aviso o de otro modo y dependen del pronto recibo por el
Vendedor de toda la informacin y asistencia requeridas o solicitadas por el Vendedor para permitirle
al Vendedor cumplir con sus obligaciones bajo el Contrato. El Vendedor no ser responsable de los
daos, prdidas o gastos incurridos por el Comprador si el Vendedor no cumple con las fecha de
entrega estimadas.
En caso que los Productos no sean recogidos por el Comprador en la fecha efectiva de la entrega, el
Vendedor podr (a su juicio exclusivo) colocar los Productos en un almacn/bodega al costo y riesgo
exclusivos del Comprador.

6. FUERZA MAYOR
El Vendedor se reserva el derecho de diferir la fecha de entrega de los Productos y/o la fecha de
suministro de los Servicios, de cancelar el Contrato, o de reducir el volumen de los Productos y/o
modificar los alcances de los Servicios ordenados por el Comprador (sin responsabilidad para el
Comprador), si se encuentra impedido o se retrasa en el cumplimiento de sus obligaciones debido a
circunstancias que escapan a su control, en la medida que sea razonable, incluyendo, pero sin limitarse
a, los desastres naturales, fuerzas naturales, terremotos, maremotos, derrumbes, inundaciones, rayos,
huracanes, tifones, tormentas u otras inclemencias del tiempo no incluidas en un planeamiento normal,
epidemias y plagas; cambios de las leyes o regulaciones, acciones del gobierno; actos de la autoridad
civil o militar; incendios, explosiones, paros patronales, huelgas y/o disputas laborales (sea que estn o
no relacionadas con los trabajadores de cualquiera de las partes); conmocin civil; protestas; guerras;
emergencia nacional; disturbios, insurreccin civil; actos de terrorismo, restricciones o retrasos en el
transporte, restricciones o retrasos en la fabricacin e incapacidad del Vendedor de obtener los
suministros adecuados o apropiados de las fuentes usuales; o actos del Comprador que tengan como
consecuencia la impracticabilidad comercial. En el caso de dicho retraso, la fecha de entrega y/o
cumplimiento ser diferida por un plazo equivalente al tiempo perdido debido a dicho retraso.

7. GARANTA
El Vendedor garantiza que los Productos fabricados por el Vendedor, siempre que sean debidamente
almacenados, encargados, instalados, usados y mantenidos, y los Servicios suministrados por el
Vendedor, estarn libres de defectos relacionados con los materiales o la mano de obra. La obligacin
del Vendedor bajo esta garanta se limitar a reponer o reparar la parte o partes de los Productos, a la
opcin del Vendedor, cuyo defecto en los materiales o mano de obra sea demostrado dentro de los
doce (12) meses desde la fecha de instalacin o dieciocho (18) meses desde la fecha de entrega, lo que
ocurra primero; o a volver a suministrar los Servicios dentro de los doce (12) meses desde el
suministro de los Servicios (PLAZO DE GARANTA), siempre que el Comprador le d al
Vendedor pronto aviso de cualquier defecto y presente prueba sustancial y en una forma satisfactoria
para el Vendedor (al juicio exclusivo de ste), incluyendo toda la informacin y documentacin
pertinentes necesarias para evaluar el rendimiento del pozo petrolero y equipo y las operaciones.
Cualquier parte o partes defectuosas deben ser devueltas con el flete prepagado por el Comprador a un
centro de servicios autorizado designado por el Vendedor para su inspeccin. El Vendedor enviar con
el flete prepagado por el Comprador, productos en reposicin de los Productos defectuosos, al destino
de entrega indicado en la orden original. Los Productos devueltos al Vendedor por los cuales el
Vendedor entregue productos en reposicin bajo esta garanta se convertirn en propiedad del
Vendedor.
LA GARANTA PRECEDENTE REMPLAZA TODA OTRA GARANTA, SEA STA EN FORMA
ORAL, ESCRITA, EXPRESA, TCITA O LEGAL, Y EL VENDEDOR NO OFRECE NINGUNA
GARANTA DE ADECUACIN DE UN BIEN PARA EL DESTINO DE USO PARTICULAR QUE

Pgina 3 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






QUIERA DARLE EL COMPRADOR, NI GARANTA DE COMERCIABILIDAD. LAS
OBLIGACIONES DE GARANTA DEL VENDEDOR Y LOS MEDIOS LEGALES DE
PROTECCIN O REPARACIN DEL COMPRADOR SON NICA Y EXCLUSIVAMENTE LOS
QUE ESTN EXPRESAMENTE PREVISTOS EN EL PRESENTE CONTRATO.
ADICIONALMENTE EL COMPRADOR RENUNCIA A CUALQUIER Y TODO TIPO DE
RECLAMO RELACIONADO CON VICIOS OCULTOS Y VICIOS REDHIBITORIOS.

NO SE PRORROGAR EL PLAZO DE GARANTA UNA VEZ QUE LAS PARTES O
PRODUCTOS HAYAN SIDO REPARADOS U OBJETO DE REPOSICIN O QUE LOS
SERVICIOS HAYAN SIDO VUELTOS A SUMINISTRAR. DICHAS PARTES O PRODUCTOS O
SERVICIOS PERMANECERN BAJO LA GARANTA NICAMENTE POR LA PORCIN NO
CADUCADA DEL PLAZO DE GARANTA. LA NICA RESPONSABILIDAD DEL VENDEDOR
SER, A SU OPCIN, REPARAR O REPONER LAS PARTES O PRODUCTOS O VOLVER A
SUMINISTRAR LOS SERVICIOS BAJO ESTA CONDICIN. EL VENDEDOR PUEDE, A SU
JUICIO EXCLUSIVO, ACREDITAR A LA CUENTA DEL COMPRADOR LA PORCIN DE
DICHAS PARTES O PRODUCTOS Y/O SERVICIOS QUE EL VENDEDOR DETERMINE SON
DEFECTUOSOS.

La garanta precedente no se aplica a: (a) los defectos causados en todo o en parte por, o atribuidos a
materiales abrasivos, corrosin debido a fluidos agresivos, rayos, suministro de voltaje inapropiado,
manejo indebido o aplicacin errada; (b) Productos o partes que son normalmente consumidos en
operacin, o que tienen una vida normal naturalmente ms corta que el PLAZO DE GARANTA; (c)
alteraciones o reparaciones llevadas a cabo sin la previa aprobacin por escrito del Vendedor, o uso de
equipo y accesorios para un fin distinto para el cual est destinado dicho equipo y accesorios; (d)
instalaciones realizadas por el Comprador, salvo que los ingenieros del Comprador hayan sido
entrenados y debidamente certificados por el Vendedor; (e) instalaciones en las que el Comprador no
haya ejercitado las prcticas de aplicacin de ingeniera para los Productos, segn fueron aprobados
por el Proveedor; (f) Productos o Servicios defectuosos, cuando el Comprador siga haciendo uso de los
Productos luego de haber tomado conocimiento del defecto, o del momento en que el Comprador debi
haber tomado conocimiento de dicho defecto, lo que ocurra primero en el tiempo; (g) defectos que
surjan o tengan conexin con informacin, dibujos, interpretaciones de diagramas, especificaciones
tcnicas o instrucciones proporcionadas por el Comprador al Vendedor.

8. LIMITACIN DE RESPONSABILIDAD
(i) PARA LOS FINES DE ESTA CONDICIN 8(i), EL TRMINO DAO
CONSECUENCIAL SIGNIFICAR (EN CADA CASO, SEA O NO PREVISIBLE A LA
FECHA DEL CONTRATO): (a) LAS PRDIDAS Y/O DAOS MEDIATOS,
INDIRECTOS, ESPECIALES, INCIDENTALES, PUNITIVOS Y/O ESPECIALES; (b) EL
LUCRO CESANTE, LA PRDIDA O DIFERIMIENTO DE PRODUCCIN, PRDIDA DE
PRODUCTO, PRDIDA DE REPUTACIN, PRDIDA DE USO, PRDIDA DE
INGRESOS, UTILIDADES EFECTIVAS O ANTICIPADAS, COSTO DE CAPITAL, EN
CADA CASO SEA EN FORMA DIRECTA O INDIRECTA, RECLAMACIONES POR
INTERRUPCIN DE SERVICIO O FALLA EN EL SUMINISTRO, COSTOS Y GASTOS
INCURRIDOS EN CONEXIN CON LOS COSTOS OPERATIVOS DE MANO DE
OBRA, TRANSPORTE O FUENTES DE SUMINISTROS O INSTALACIONES
SUSTITUTAS, MANO DE OBRA EMPLEADA EN CONEXIN CON EL RETIRO Y
REPOSICIN DE PRODUCTOS DENTRO DEL POZO O CUALESQUIERA OTRAS
PRDIDAS O DAOS INCURRIDOS COMO CONSECUENCIA O EN CONEXIN CON
LA INTERRUPCIN DEL SERVICIO, EN CADA CASO.
NO OBSTANTE DISPOSICIN EN CONTRARIO EN OTRA PARTE, EN NINGN
CASO EL VENDEDOR SER RESPONSABLE POR LOS DAOS CONSECUENCIALES
Y EL COMPRADOR SER RESPONSABLE Y LIBRAR, INDEMNIZAR,
DEFENDER Y MANTENDR INDEMNE AL GRUPO DEL VENDEDOR FRENTE A
LOS DAOS CONSECUENCIALES, AUN CUANDO FUERAN CAUSADOS POR LA
NEGLIGENCIA O CULPA, SOLIDARIA, CONJUNTA, CONCURRENTE O PARCIAL

Pgina 4 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






DEL VENDEDOR, RESPONSABILIDAD OBJETIVA O RESPONSABILIDAD DEL
FABRICANTE, Y SIN CONSIDERACIN DE LA FORMA DE ACCIN, SEA QUE SE
TRATE DE RESPONSABILIDAD CONTRACTUAL, EXTRACONTRACTUAL
(INCLUYENDO LA NEGLIGENCIA O CULPA), VIOLACIN DE GARANTA,
INDEMNIZACIN, POR OPERACIN DE LA LEY, O DE OTRO MODO.

(ii) LA RESPONSABILIDAD TOTAL DEL VENDEDOR EN CUALQUIER ACCIN SEA
POR RESPONSABILIDAD CONTRACTUAL, EXTRACONTRACTUAL (INCLUYENDO
LA NEGLIGENCIA SOLIDARIA, CONJUNTA O CONCURRENTE), O QUE DE OTRO
MODO SURJA, SE RELACIONE O RESULTE DE LA FABRICACIN, VENTA,
ENTREGA, REVENTA, REPARACIN, REPOSICIN O USO DEL PRODUCTO, O DEL
SUMINISTRO DEL SERVICIO, O DEL CUMPLIMIENTO O FALTA DE
CUMPLIMIENTO DEL CONTRATO, NO EXCEDER DEL PRECIO RECIBIDO POR EL
VENDEDOR POR EL PRODUCTO O PARTE DEL MISMO, O DEL COSTO DE
SUMINISTRO DE CUALQUIER TRABAJO DE SERVICIO QUE D LUGAR A LA
ACCIN AL EFECTO, EL GRUPO DEL COMPRADOR RENUNCIA A INICIAR
CUALQUIER ACCIN EN CONTRA DEL GRUPO DEL VENDEDOR PARA
PERSEGUIR CUALQUIER INDEMNIZACIN POR SOBRE LOS LMITES PACTADOS
EN ESTA CONDICIN, Y SE OBLIGA A INDEMNIZAR, DEFENDER Y MANTENER
AL GRUPO DEL VENDEDOR LIBRE DE Y POR CUALQUIER RESPONSABILIDAD
QUE EXCEDA EL LMITE DE RESPONSABILIDAD PACTADO EN ESTA SECCIN,
AN CUANDO LA MISMA SEA GENERADA A FAVOR DE CUALQUIER MIEMBRO
DEL GRUPO DEL COMPRADOR, O DE SUS CONTRATISTAS, SUBCONTRATISTAS,
OPERADORES Y/O EL DUEO DEL POZO (EL TRMINO DUEO DE POZO
DEBER INCLUIR PERSONAS O ENTIDADES CON CUALQUIER TIPO DE
DERECHOS O INTERS SOBRE EL POZO Y/O INSTALACIONES), Y AN CUANDO
ESTOS DAOS SEAN GENERADOS POR LA NEGLIGENCIA DEL GRUPO DEL
COMPRADOR Y/O DEL GRUPO DEL VENDEDOR.
(iii) EL COMPRADOR ENTIENDE Y ACUERDA QUE LAS LIMITACIONES A LA
RESPONSABILIDAD PRECEDENTES SON PARTE ESENCIAL DEL CONTRATO Y
QUE EN AUSENCIA DE DICHAS LIMITACIONES, LOS TRMINOS MATERIALES Y
ECONMICOS DE ESTE CONTRATO SERAN ESENCIALMENTE DIFERENTES.

9. INDEMNIZACIN E INDEMNIDAD
Todas las exclusiones e indemnidades estipuladas bajo esta Condicin 9 (salvo por las previstas bajo las
Condiciones 9.1(c) y 9.2(c)) y la Condicin 8 (i), se aplicarn sin consideracin de la causa y no obstante
la negligencia, culpa o violacin de obligaciones (sea por ley o de otro modo) de la parte indemnizada
o de cualquier otra entidad o parte y se aplicarn sin consideracin de si la accin fue de carcter
contractual, extracontractual o, de otro modo, por operacin de la ley. Para los propsitos de las
Condiciones 9.1(c) y 9.2 (c), tercero significar cualquier parte que no sea miembro del Grupo del
Comprador ni del Grupo del Vendedor.
9.1. El Vendedor ser responsable y librar, indemnizar, defender y mantendr indemne al Grupo del
Comprador frente a cualquier accin, prdida, dao, costo (incluyendo los costos legales), gasto y otras
responsabilidades, con respecto a lo siguiente:
(a) Sujeto a la condicin 9.2(d), la prdida o dao a la propiedad (distinta a los Productos luego de su
entrega conforme con la Condicin 5) del Grupo del Vendedor, sea que con respecto a sta el
Grupo del Vendedor sea el propietario, o la haya contratado, arrendado o que por el contrario haya
sido provista por el Grupo del Vendedor como consecuencia o en relacin con el cumplimiento del
Contrato;
(b) Los daos a personas, incluyendo la muerte o enfermedad de cualquier persona empleada por el
Grupo del Vendedor, como consecuencia o vinculados al cumplimiento del Contrato;
(c) Sujeto a la condicin 9.3, los daos a terceros, incluyendo la muerte, enfermedad, prdida o daos
a la propiedad de un tercero, en la medida que dichos daos, prdidas o daos sean causados por la


Pgina 5 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






negligencia, culpa o violacin de obligaciones (sea por operacin de la ley o de otro modo) del
Grupo del Vendedor.

9.2. El Comprador ser responsable y librar, indemnizar, defender y mantendr indemne al Grupo del
Vendedor frente a cualquier accin, prdida, dao, costo (incluyendo los costos legales), gasto y otras
responsabilidades, con respecto a lo siguiente:
(a) Prdidas o daos a la propiedad del Grupo del Comprador, ya sea:-
(i) que el Grupo del Comprador sea el propietario, o
(ii) que la propiedad haya sido contratada, arrendada o que haya sido, provista por o para
el Grupo del Comprador (incluyendo los Productos despus de la entrega conforme
con la Condicin 5); y
(b) Los daos a personas, incluyendo la muerte o enfermedad de cualquier persona empleada por el
Grupo del Comprador, como consecuencia o en relacin con el cumplimiento o falta de
cumplimiento del Contrato; y
(c) Sujeto a cualesquiera otras estipulaciones del Contrato, los daos a terceros, incluyendo la muerte,
enfermedad, prdida o daos a la propiedad de un tercero, en la medida que dichos daos, prdidas
o daos sean causados por negligencia, culpa o violacin de obligaciones (sea por operacin de la
ley o de otro modo) del Grupo del Comprador; y
(d) A la opcin del Vendedor, la reparacin, reposicin o reembolso del costo total del equipo,
herramientas y/o instrumentos del Vendedor debido a su prdida o dao en el fondo del pozo del
Comprador durante el suministro de los Servicios, o debido a su prdida o dao por la abrasin o
corrosin ocasionada por efluentes del pozo, salvo que dicha prdida o daos se deba a la
negligencia del Vendedor.

9.3. No obstante la Condicin 9.1, el Comprador ser responsable y defender, indemnizar y
mantendr indemne al Grupo del Vendedor frente a toda accin que sea consecuencia del
cumplimiento o falta de cumplimiento del Contrato en relacin con lo siguiente, y sea o no que resulte
de o este relacionada con la negligencia del Grupo del Vendedor: (i) prdidas o daos al pozo o
perforacin o a cualquier instalacin de produccin de petrleo y gas de terceros; (ii) percolacin o
contaminacin del depsito que se origine en el subsuelo o que provenga de la propiedad del
Comprador o tercero no obstante la causa como se origine; (iii) voladura, incendio, explosin,
depresin topogrfica de cualquier pozo o depsito o cualquier otra condicin no controlada de un
pozo (incluyendo los costos para controlar un pozo descontrolado y la remocin de escombros); (iv)
daos o fuga del producto o sustancia de una instalacin, incluyendo un oleoducto u otra instalacin
subterrnea.

9.4. No obstante disposicin en contrario del Contrato, el Comprador ser responsable y librar,
indemnizar, defender y mantendr indemne al Grupo del Vendedor frente a cualquier accin,
prdida, dao, costo (incluyendo los costos legales), gasto y otras responsabilidades, con respecto a los
actos u omisiones de los empleados o agentes del Grupo del Vendedor en conexin con el
cumplimiento de los Servicios (o cualquier parte de los Servicios), cuando, conforme con el Contrato, los
empleados del Grupo del Vendedor estn bajo la supervisin, direccin o control del Comprador con
respecto a dichos Servicios o parte de dichos Servicios.
10. FALTA DE ENTREGA
La cantidad de cualquier envo de Productos conforme el registro del Vendedor como despachados
desde la sede de operaciones del Vendedor u otro lugar designado ser prueba concluyente de la
cantidad recibida por el Comprador, salvo que el Comprador pueda ofrecer prueba demostrando lo
contrario. El Vendedor no ser responsable de la falta de entrega de Productos (aun cuando fuera
causada por la negligencia del Vendedor), salvo que el Comprador d un aviso por escrito al Vendedor
sobre la falta de entrega dentro de cuarenta y ocho (48) horas de la fecha y hora en que el Producto
hubiera sido recibido en el curso normal de las operaciones. Cualquier responsabilidad del Vendedor
por falta de entrega de los Productos se limitar, a juicio exclusivo del Vendedor, ya sea a la reposicin
de los Productos o a la emisin de una nota de crdito contra una factura expedida por los Productos.
11. VIOLACIN DE PATENTE

Pgina 6 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)







Si el Comprador es objeto de una reclamacin o de otro modo toma conocimiento que un Producto o
parte del mismo fabricado por el Vendedor infringe en forma real o presunta una patente u otro
derecho de propiedad intelectual, el Comprador notificar de inmediato al Vendedor por escrito
dndole informacin, asistencia y autoridad exclusiva para evaluar, defender y conciliar dicha accin o
infraccin potencial. El Vendedor entonces a su propio costo y opcin: (a) conciliar dicha accin; (b)
le facilitar al Comprador el derecho de usar dicho Producto; (c) lo repondr o modificar para evitar la
infraccin; (d) lo retirar y reembolsar el precio de compra (incluyendo los costos de transportacin e
instalacin), menos una cantidad razonable por concepto de depreciacin; o (e) se defender ante dicha
accin.
12. CANCELACIN Y CAMBIOS
El Comprador no puede cancelar o reprogramar la fecha de entrega de los Productos y/o Servicios a ser
provistos bajo el Contrato sin el previo consentimiento por escrito del Vendedor. En caso que el
Vendedor d dicho consentimiento, dicha cancelacin o reprogramacin con respecto a los Productos
y/o Servicios por parte del Comprador dar lugar a un cobro al Comprador, el cual ser determinado
por el Vendedor. Todos los Productos especialmente diseados o modificados que sean cancelados
despus del inicio de su fabricacin sern objeto de un cargo por cancelacin, el cual incluir todos los
costos y un margen razonable por el tiempo empleado, segn lo determine el Vendedor. Los cargos de
cancelacin por accesorios y componentes abastecidos por terceros sern cobrados por el monto total
del precio. El Vendedor, a su juicio exclusivo, ajustar el precio o las fechas de entrega, o har las
modificaciones que puedan requerirse como consecuencia de cualquier orden de cambio cuya
expedicin haya sido acordada por el Comprador y el Vendedor. No ser vlida la modificacin de la
orden de compra o Acuse de Recibo de la Orden u orden de cambio sino es aceptada por escrito por el
Vendedor (a su juicio exclusivo).
13. RENUNCIA
Cualquier renuncia por el Vendedor a una violacin o incumplimiento de las obligaciones del
Comprador bajo el Contrato, o cualquier omisin del Vendedor en ejercer los derechos que surjan bajo el
Contrato, bajo ninguna circunstancia se interpretar como una renuncia a cualquier otra violacin o
incumplimiento posterior por parte del Comprador ni al derecho del Vendedor a ejercer sus derechos
conforme el presente Contrato. En caso de cualquier incumplimiento por el Comprador, el Vendedor
puede negarse a hacer ms embarques. Si el Vendedor elige continuar haciendo entregas, la accin del
Vendedor no constituir una renuncia a dicho incumplimiento ni afectar los medios legales de
proteccin o reparacin del Vendedor por dicho incumplimiento.

14. TOTALIDAD DEL CONTRATO
El Acuse de Recibo de la Orden, las Condiciones Especiales y estos Trminos y Condiciones Estndar
constituyen la totalidad del contrato entre las partes con respecto a la venta de los Productos y/o
Servicios y revoca todas las comunicaciones, representaciones o acuerdos, previos sean orales o
escritos, con respecto al objeto del presente. Las representaciones o declaraciones previas, relacionadas
con la venta de los Productos y/o Servicios, formuladas por un representante del Vendedor, que no
estn contenidas en el presente, no sern vinculantes para el Vendedor.
15. CONTROL DE EXPORTACIONES
El Comprador acepta que, salvo que se obtenga previa autorizacin del Departamento de Comercio de
EE.UU., ni el Comprador ni sus subsidiarias exportarn, reexportarn o pondrn en circulacin, directa
o indirectamente, ningn Producto recibido del Vendedor, a ningn pas o destino al cual est
prohibida la exportacin, reexportacin o puesta en circulacin de la tecnologa o Producto por las
Regulaciones de la Administracin de Exportacin del Departamento de Comercio de EE.UU.
(EAR, por sus siglas en ingls), o est prohibido por las leyes de los EE.UU. o por leyes que no sean
de los EE.UU. que sean aplicables.
El Comprador ser responsable de obtener la licencia de exportacin u otra documentacin que sea
necesaria antes de la exportacin o reexportacin de los Productos adquiridos del Vendedor bajo el
Contrato. Asimismo, el Comprador dar un aviso sobre la necesidad de cumplir con dichas leyes y

Pgina 7 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






regulaciones a cualquier persona, firma o entidad que tenga razn para creer que obtendr dichos
Productos del Comprador con la intencin de exportarlos. Cada parte obtendr, a su propio costo, las
licencias y documentos de exportacin e importacin que sean necesarios para cumplir con sus
obligaciones bajo el Contrato. Si no se pueden obtener las aprobaciones, el Vendedor podr dar por
terminado, cancelado o por el contrario quedar exonerado del cumplimiento de las obligaciones que
pueda tener bajo el Contrato. Cualquier clasificacin de exportacin hecha por el Vendedor ser slo
para el uso interno del Vendedor y no se interpretar como una representacin o garanta con respecto
a la debida clasificacin de exportacin de cada Producto o si se necesita una licencia de exportacin u
otra documentacin para la exportacin del Producto. Esta Condicin 15 sobrevivir a la terminacin
del Contrato.

16. TICA COMERCIAL
Ni el Vendedor ni el Comprador harn pagos ni tomarn ninguna accin que pudiera ser interpretada
como dirigida al pago de dinero u otro artculo de valor en favor de un funcionario gubernamental,
partido poltico o candidato de un partido poltico para los fines de influenciar los actos o inducir a un
funcionario gubernamental para que haga uso de sus influencias para asistir en la obtencin o retencin
de negocios en un pas, en una forma que sea ilegal o que sujete al Vendedor a sanciones de carcter
civil o penal, o que sean incompatibles con la Poltica de tica Comercial del Vendedor.

17. CESIN
El Vendedor podr dar en cesin el Contrato o cualquier parte del mismo a cualquier persona, firma o
empresa. El Comprador no tendr derecho a dar en cesin el Contrato ni ninguna parte del mismo sin el
previo consentimiento por escrito del Vendedor.

18. ARBITRAJE
Cualquier disputa que surja o tenga relacin con el Contrato, incluyendo una disputa en cuanto a la
validez de los Trminos y Condiciones Estndar y de esta Condicin 18, ser resuelta mediante
arbitraje en Houston realizado en espaol por un solo rbitro, de conformidad con las Reglas del
Tribunal Internacional de Arbitraje de Londres o LCIA, siglas en ingls de The London Court of
International Arbitration).
19. LEY APLICABLE
Estos Trminos y Condiciones Estndar se interpretarn para todos los efectos y se les dar efecto legal de
conformidad con las leyes de [pas del Vendedor], no obstante los principios de conflicto de leyes. No
ser aplicable la Convencin de las Naciones Unidas sobre los Contratos para la Venta
Internacional de Mercaderas.
20. ESTIPULACIONES VARIAS
Todas las muestras, dibujos, materiales descriptivos, especificaciones y publicidad proporcionados por el
Vendedor y las descripciones o ilustraciones contenidas en los catlogos o folletos del Vendedor son
publicados o emitidos con el nico fin de dar una idea aproximada de los Productos y/o Servicios
descritos en los mismos. stos no formarn parte del Contrato.
A su propio costo, el Comprador obtendr los permisos o cualquier otra autorizacin (incluyendo, con
carcter enunciativo pero no limitativo, los permisos de trabajos y visas para empleados del Vendedor), los
cuales pueden ser requeridos para permitirle al Vendedor cumplir con los Servicios. El Comprador acepta
indemnizar al Vendedor frente los costos, reclamaciones, acciones, demandas o gastos incurridos o
sufridos en conexin con el incumplimiento del Comprador en obtener los permisos o autorizaciones
requeridos para cumplir con los Servicios.
Si una corte, tribunal u organismo administrativo de jurisdiccin competente encontrara que una
estipulacin del Contrato es en todo o en parte ilegal, invlida, nula, anulable, inejecutable o
irrazonable, en la medida de dicha ilegalidad, invalidez, nulidad, anulabilidad, inejecutabilidad o
irrazonabilidad, la estipulacin se considerar divisible, y el resto de las estipulaciones del Contrato,
como el resto de dicha estipulacin, continuarn en pleno efecto y vigor.


Pgina 8 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)






Estos Trminos y Condiciones Estndar estn sujetos a cambio sin previo aviso por escrito, en cualquier
momento y cuando convenga, a juicio exclusivo del Vendedor. Todas las comunicaciones entre las partes
acerca del Contrato se harn por escrito y se entregarn en forma personal o se enviarn por fax a la oficina
registrada o a cualquier otra direccin segn sea notificado a la otra parte. Las comunicaciones entregadas en
forma personal se considerarn recibidas el da de la entrega o, si son enviadas por fax, el da hbil y a la hora
de la transmisin, o por el contrario, el siguiente da hbil.

























































Pgina 9 de 9 WG ESP- Trminos y Condiciones de Venta Estandar Internacional (0 3)
Clean (2)





Wood Group ESP, Inc.
North American Operations
Wood Group ESP
Corporate Headquarters & Operations Corporate Sales Office
5500 S.E.59th St.(73135) 19416 Park Row, Suite 100
P.O. Box 15070 (73155) Houston,TX 77084 USA
Oklahoma City, OK USA Telephone:(281) 492-5100
Telephone: (405) 670-1431 Facsimile: (281) 492-8107
(800) 723-3771
Facsimile: (405) 670-5463
E-mail: esp@woodgroup.com
www.woodgroup-esp.com

Wood Group ESP Sales and Service Locations
Canada
Wood Group ESP (Canada) Ltd
Bay 6, 360 Aquaduct Dr.
Brooks, Alberta T1R 1E4 Canada
Telephone: (403) 501-5822
Facsimile: (403) 501-5823

Wood Group ESP (Canada) Ltd
300,1015-4th St. SW
Calgary, Alberta T2R 1J4 Canada
Telephone: (403) 263-7166
Facsimile: (403) 263-7211

Wood Group ESP (Canada) Ltd
3917 81 Avenue
Leduc, Alberta T9E 8S6 Canada
Telephone: (780) 955-2165
(888) 586-8909
Facsimile: (780) 955-9487

Colorado
410 17th Street, Suite 1260
Denver, CO 80202 USA
Telephone: (303) 350-2111
(800) 535-0310
Facsimile: (303) 350-2112

Mississippi
45 Jerry Doggett Dr.
Laurel, MS 39443 USA
Telephone: (601) 649-2030
(800) 488-9260
Facsimile: (601) 649-8819

Wood Group ESP, Inc.
New Mexico
509 Commerce Rd.
Artesia, NM 88210 USA
Telephone: (505) 746-4614
Facsimile: (505)746-4519

8426 North Dal Paso
Hobbs, NM 88242 USA
Telephone: (505) 392-7999
Facsimile: (505) 391-8190

Oklahoma
5500 S.E.59th St.(73135)
P.O. Box 15070 (73155)
Oklahoma City, OK USA
Telephone: (405) 670-1431
(800) 723-3771
Facsimile: (405) 670-5463

1739 Hardcastle Ind. Blvd.
P.O. Box 1680
Purcell, OK 73080 USA
Telephone: (405) 527-1566
(800) 256-5058
Facsimile: (405) 527-7161










The ESP Specialists
Texas
1700 S.W. Mustang Dr.
P.O. Box 947
Andrews, TX 79714 USA
Telephone: (432) 523-9701
Facsimile: (432) 523-9700
19416 Park Row, Suite 100
Houston,TX 77084 USA
Telephone: (281) 492-5100
Facsimile: (281) 492-8107
2707 S.County Rd.1208 (79706)
P.O. Box 80130 (79708)
Midland, TX USA
Telephone: (432) 699-7401
(800) 749-7402
Facsimile: (432) 699-4159
2507 25th St. (79549)
P.O. Box 916 (79550)
Snyder, TX USA
Telephone: (325) 573-8101
Facsimile: (325) 573-1616
Wyoming
1845 N. Oilfield Center
Casper, WY 82604
Telephone: (307) 234-4495
(800) 535-0306
Facsimile: (307) 234-4497



www.woodgroup-esp.com
Product Catalog - Facilities - Copyright Wood Group ESP, Inc. October 2009 revised October, 2009 Page-1




Wood Group ESP, Inc.
Wood Group ESP International Operations
ASIA PACIFIC
Indonesia
PT ESP Mulia Indonesia
Balai Raja Industrial Park
JL. Raya, Duri-
Pekanbaru Road, KM 11 Duri,
Riau Province, Sumatra 28884
Telephone:+62-765-561904
Facsimile: +62-765-561923

PT Indobornusa Mandiri
Wisma Staco 6th Floor
Jl.Casablanca Kav.18
Jakarta, Indonesia 12870
Telephone: +62 (21) 8370-2455
Facsimile: +62 (21) 831-2345

Singapore
PTE Ltd.
Shaw Tower #28-09
100 Beach Road
Singapore, 189702
Telephone: +65-6396-3626
Facsimile: +65-6396-5362

EUROPE / AFRICA
Africa
EDGO-Trading TChad
1033, Rue de la Gendarmerie
BP 5496, NDjamena, Tchad
Telephone: +235 524 757
+44 20707 42974
+44 20707 41777
Facsimile: +235 524 757

United Kingdom
Maersk House, Greenbank Rd
East Tullos, Aberdeen AB12 3BR
Scotland
Telephone: +44-1224-21 6636
Facsimile: +44-1224-21 6770

England
Telephone: +44-1564-77-1739
Facsimile: +44-1564-77-1739


Wood Group ESP, Inc.
LATIN AMERICA
Argentina
Reconquista 1016 Piso 6
Buenos Aires, 1003 Argentina
Telephone:+54-11-4-311-9411
Facsimile: +54-11-4-311-2980

Dalle Mura 150
Comodoro Rividavia
Chubut 9000 Argentina
Telephone:+54-297-446-8254
Facsimile: +54-297-447-8377
Brazil
65 Rua Antonio Vita
Jardim Vonfiglioli
CEP- 05593-080
Sao Paulo , Brazil
Telephone:+55-11-3731-2999
Facsimile: +55-11-3731-2998
Colombia
Wood Group Colombia,
Colombser SA
Carrera 11A #93-97 Office 204
Bogota, Colombia, Sur America
Telephone:+57-1-621-2424
Facsimile: +57-1-621-2275
Ecuador
Panamericana Norte Km. 12 1/2
entre pasaje Alfonso Moncayo y
calle El Arenal, Parque Delta
Quito Ecuador
Telephone:+593-2-2428-211
Facsimile: +593-2-2428-213
Venezuela
Avenidad Cuatricentenario
Barinas Sede De La Toyota
Barinas, EdoBarinos, Venezuela
Codigo Postal 5201
Telephone:+58-273-546-1241
Facsimile: +58-273-546-2653

Av Intercomunal antigua
sede Motoriente, El Tigre - Tigrito
Edo Anzoategui, Venezuela
Telephone:+58-283-241-7151
Facsimile: +58-283-241-8613
The ESP Specialists

Venezuela -continued
Zona Industrial Segunda
Km 6 via a Perija
Sector El Callao,
Municipio San Francisco
Maracaibo, Edo Zulia, Venezuela
4001
Telephone:+58-261-200-9200
Facsimile: +58-261-736-1993
MIDDLE EAST
Dubai
Oilfield Supply Center Ltd.
Jebel Ali Free Zone
Building No.50 P.O. Box 18131
Dubai, United Arab Emirates
Telephone:+971-4-883-7595
Facsimile: +971-4-883-7579
Kuwait
c/o Klalid Y. Al Fulaij Est.
P.O. Box 22414
Safat 13085 Kuwait
Telephone:(965)398-3639-2810
Facsimile: (965)398-3639 2811
Oman
c/o Oman Oilfield Supply Center
P.O. Box 104
Shati Al Qurum,
Sultanate of Oman
Telephone: +968-605501, 691091
Facsimile: +968-605784
RUSSIA
Moscow
#8 Leningradsky Prospect
Office #4012-4015
Moscow, Russia 125040
Telephone: +7-502-937-6641
Facsimile: +7-502-937-6642
Wood Group ESP Service, Ltd
#5 Kuzovatkin Street
Nizhnevartovsk, Tyumen Region
628606
Telephone: +7 3466-416-195
Facsimile: +7 3466-416-295

www.woodgroup-esp.com
Page-2 revised October, 2009 Product Catalog - Facilities - Copyright Wood Group ESP, Inc. - October, 2009

Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13
ENGINEERING DATA TA-1200 60 HZ
114.3 MM
4-1/2 IN
6000 PSI
6000 PSI
6000 PSI
85.73MM
3-3/8 IN
125 HP
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
Pump Performance Curve for TA-1200 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
78 HP
0
5
10
15
20
Ft
2
4
6
M
Head
0 200 400 600 800 1000 1200 1400 1600 1800
0%
20%
40%
60%
80%
BPD
50 100 150 200 250
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.2
0.4
0.6
0.8
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TA-1200 50 HZ
Pump Performance Curve for TA-1200 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
4-1/2 IN
114.3 MM
3-3/8 IN 5/8 IN
85.73MM 15.88MM
60 HZ 50 HZ
6000 PSI 192 HP 160 HP
6000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
M
5
10
15
Ft
Head
0 50 100 150 200 250
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
M3/DAY
250 500 750 1000 1250 1500
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
0.9
1.0
1.1
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 35 15.9 13 912667
2 3.5 1.07 57 25.9 27 912675
3 4.9 1.49 81 36.7 45 912683
4 6.3 1.92 104 47.2 61 912691
5 7.8 2.38 128 58.1 77 912709 70 113552
6 9.1 2.77 152 68.9 93 912717 86 113732
7 10.5 3.20 174 78.9 108 912725
8 11.9 3.63 193 87.5 124 912733
9 13.3 4.05 221 100.2 140 912741
10 14.8 4.51 244 110.7 156 912758 145 113735
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5
Coupling for Intake or GS 0.25 0.08 0.4 0.18
Pump to Pump Coupling - FLT
0.18
0.05 0.18 0.08
Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15
TA-1200 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
1021310
120555
914341
912022
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-16 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TA-1200 1 stage, S.G. = 1
0
5
10
15
20
25
30
35
40
Ft
2
4
6
8
10
12
M
Head
0 500 1000 1500 2000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17
ENGINEERING DATA TA-1500 60 HZ
114.3 MM
4-1/2 IN
6000 PSI
6000 PSI
6000 PSI
85.73MM
3-3/8 IN
167 HP
50 HZ 60 HZ
11/16 IN
17.46MM
125 HP
200 HP
255 HP 213 HP
Pump Performance Curve for TA-1500 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
104 HP
0
5
10
15
Ft
2
4
M
Head
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800
0%
25%
50%
75%
BPD
50 100 150 200 250 300 350 400
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.5
1.0
1.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-18 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TA-1500 50 HZ
Pump Performance Curve for TA-1500 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
4-1/2 IN
114.3 MM
3-3/8 IN 11/16 IN
85.73MM 17.46MM
60 HZ 50 HZ
6000 PSI 255 HP 213 HP
6000 PSI 125 HP 104 HP
6000 PSI 200 HP 167 HP
0
0.5
1
1.5
2
2.5
3
3.5
4
M
5
10
Ft
Head
0 50 100 150 200 250 300 350
0%
10%
20%
30%
40%
50%
60%
70%
80%
M3/DAY
250 500 750 1000 1250 1500 1750 2000 2250
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
0.9
1.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 38 17.2 10 912766 9 140601
2 3.5 1.07 65 29.5 23 912774 21 140602
3 4.9 1.49 91 41.3 35 912782 32 140603
4 6.3 1.92 118 53.5 48 912790 45 140604
5 7.8 2.38 145 65.8 60 912808 56 140605
6 9.1 2.77 172 78.0 73 912816 68 140606
7 10.5 3.20 198 89.8 85 912824 79 140607
8 11.9 3.63 226 102.5 96 912832 91 140608
9 13.3 4.05 252 114.3 110 912840 103 140609
10 14.8 4.51 279 126.6 123 912857 114 140610
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5
Coupling for Intake or GS 0.2 0.06 0.4 0.18
Pump to Pump Coupling - FLT
0.2
0.06 0.18 0.08
Pump to Pump Coupling - CMP 0.2 0.06 0.18 0.08
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19
TA-1500 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
1021310
120556
934182
120556
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-20 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TA-1500 1 stage, S.G. = 1
0
5
10
15
20
25
30
35
Ft
2
4
6
8
10
12
M
Head
0 500 1000 1500 2000 2500 3000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300 400
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
78 HP
Pump Performance Curve for TA-400 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
ENGINEERING DATA TA-400 60 HZ
114.3 MM
4-1/2 IN
6000 PSI
6000 PSI
6000 PSI
85.73MM
3-3/8 IN
125 HP
0
5
10
15
20
Ft
2
4
6
M
Head
0 100 200 300 400 500 600 700
0%
20%
40%
60%
80%
Efficiency
Power
BPD
25 50 75 100
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.3
0.5
0.8
1.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
6000 PSI 192 HP 160 HP
6000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
5/8 IN
85.73MM 15.88MM
60 HZ
4-1/2 IN
114.3 MM
3-3/8 IN
Pump Performance Curve for TA-400 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TA-400 50 HZ
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
M
5
10
15
Ft
Head
0 10 20 30 40 50 60 70 80 90
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
Head
M3/DAY
50 100 150 200 250 300 350 400 450 500 550
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.0
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
HP
MTR
LOAD
Qmin BEP Qmax
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 34 15.4 16 917378 15 113871 15 113981
2 3.5 1.07 55 24.9 35 917385 33 113872 33 113982
3 4.9 1.49 75 34.0 54 917393 50 113873 50 113983
4 6.3 1.92 96 43.5 74 917401 69 113874 69 113984
5 7.8 2.38 118 53.5 93 917419 86 113875 86 113985
6 9.1 2.77 139 63.0 112 917427 104 113876
7 10.5 3.20 160 72.6 132 917435 122 113877
8 11.9 3.63 181 82.1 151 917443 139 113878
9 13.3 4.05 202 91.6 157 113879
10 14.7 4.48 223 101.2 174 113880
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5
Coupling for Intake or GS 0.25 0.08 0.4 0.18
Pump to Pump Coupling - FLT
0.18
0.05 0.18 0.08
Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
1021310
120555
914341
912022
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TA-400 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TA-400 1 stage, S.G. = 1
0
5
10
15
20
25
30
35
40
45
Ft
2
4
6
8
10
12
14
M
Head
0 100 200 300 400 500 600 700 800 900
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
25 50 75 100 125
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
78 HP
Pump Performance Curve for TA-550 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
ENGINEERING DATA TA-550 60 HZ
114.3 MM
4-1/2 IN
6000 PSI
6000 PSI
6000 PSI
85.73MM
3-3/8 IN
125 HP
0
5
10
15
20
25
30
Ft
2
4
6
8
M
Head
0 100 200 300 400 500 600 700 800 900
0%
10%
20%
30%
40%
50%
60%
Efficiency
Power
BPD
25 50 75 100 125
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
HP
MTR
LOAD
Qmin BEP Qmax
Head
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
6000 PSI 192 HP 160 HP
6000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
5/8 IN
85.73MM 15.88MM
60 HZ
4-1/2 IN
114.3 MM
3-3/8 IN
Pump Performance Curve for TA-550 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TA-550 50 HZ
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
M
5
10
15
Ft
Head
0 25 50 75 100 125
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
Head
M3/DAY
100 200 300 400 500 600 700
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.0
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
HP
MTR
LOAD
Qmin BEP Qmax
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 38 17.2 16 912873 15 113961 15 103140
2 3.5 1.07 63 28.6 35 912881 33 113962 33 103141
3 4.9 1.49 88 39.9 54 912899 50 113963 50 103142
4 6.3 1.92 107 48.5 74 912907 69 113964 59 103143
5 7.8 2.38 141 64.0 93 912915 86 113965 86 103144
6 9.1 2.77 167 75.8 112 912923 104 113966
7 10.5 3.20 193 87.5 132 912931 122 113967
8 11.9 3.63 219 99.3 151 912949 139 113968
9 13.3 4.05 245 111.1 170 912956 157 113969
10 14.8 4.51 271 122.9 190 912964 174 113970
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5
Coupling for Intake or GS 0.25 0.08 0.4 0.18
Pump to Pump Coupling - FLT
0.18
0.05 0.18 0.08
Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
1021310
120555
914341
912022
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TA-550 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TA-550 1 stage, S.G. = 1
0
10
20
30
40
50
Ft
4
8
12
16
M
Head
0 200 400 600 800 1000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
50 100 150
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9
ENGINEERING DATA TA-900 60 HZ
114.3 MM
4-1/2 IN
6000 PSI
6000 PSI
6000 PSI
85.73MM
3-3/8 IN
125 HP
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
Pump Performance Curve for TA-900 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
78 HP
0
5
10
15
20
Ft
2
4
6
M
Head
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
0%
20%
40%
60%
80%
BPD
25 50 75 100 125 150 175 200 225
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 3.375 / 85.8 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TA-900 50 HZ
Pump Performance Curve for TA-900 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
4-1/2 IN
114.3 MM
3-3/8 IN 5/8 IN
85.73MM 15.88MM
60 HZ 50 HZ
6000 PSI 192 HP 160 HP
6000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
M
5
10
15
Ft
Head
0 25 50 75 100 125 150 175 200
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
M3/DAY
100 200 300 400 500 600 700 800 900 1000 1100 1200
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.0
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 38 17.2 16 914499 15 140551 15 103149
2 3.5 1.07 63 28.6 35 912576 33 140552 33 103150
3 4.9 1.49 88 39.9 54 912584 50 140553 50 103151
4 6.3 1.92 107 48.5 74 912592 69 140554 69 103152
5 7.8 2.38 141 64.0 93 912618 86 140555 86 103153
6 9.1 2.77 167 75.8 112 912618 104 140556
7 10.5 3.20 193 87.5 132 912626 122 140557
8 11.9 3.63 219 99.3 151 912634 139 140558
9 13.3 4.05 245 111.1 170 912642 157 140559
10 14.8 4.51 271 122.9 190 912659 174 140560
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5
Coupling for Intake or GS 0.25 0.08 0.4 0.18
Pump to Pump Coupling - FLT
0.18
0.05 0.18 0.08
Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
TA-900 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
1021310
120555
914341
912022
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TA-900 1 stage, S.G. = 1
0
5
10
15
20
25
30
35
40
Ft
2
4
6
8
10
12
M
Head
0 200 400 600 800 1000 1200 1400 1600
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
50 100 150 200 250
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-21
104 HP
Pump Performance Curve for TD-1250 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
11/16 IN
17.46MM
125 HP
200 HP
255 HP 213 HP
ENGINEERING DATA TD-1250 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
167 HP
0
5
10
15
20
25
30
35
Ft
2
4
6
8
10
M
Head
0 250 500 750 1000 1250 1500 1750 2000
0%
10%
20%
30%
40%
50%
60%
70%
BPD
50 100 150 200 250 300
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.3
0.5
0.8
1.0
1.3
1.5
1.8
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-22 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
8000 PSI 255 HP 213 HP
5000 PSI 125 HP 104 HP
6000 PSI 200 HP 167 HP
11/16 IN
101.60MM 17.46MM
60 HZ
5-1/2 IN
139.7 MM
4 IN
Pump Performance Curve for TD-1250 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TD-1250 50 HZ
0
1
2
3
4
5
6
7
M
5
10
15
20
Ft
Head
0 25 50 75 100 125 150 175 200 225 250
0%
10%
20%
30%
40%
50%
60%
70%
M3/DAY
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
0.9
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 14 192421 13 192381 13 192391 12 192411
2 3.5 1.07 74 33.6 30 192422 29 192382 29 192392 27 192412
3 4.9 1.49 105 47.6 47 192423 45 192383 43 192393 41 192413
4 6.3 1.92 135 61.2 63 192424 62 192384 58 192394 56 192414
5 7.8 2.38 166 75.3 79 192425 78 192385 73 192395 71 192415
6 9.2 2.80 196 88.9 95 192426 94 192386 87 192396 87 192416
7 10.6 3.23 226 102.5 111 192427 102 192397
8 12 3.66 257 116.6 128 192428 117 192398
9 13.4 4.08 287 130.2 144 192429 131 192399
10 14.8 4.51 318 144.2 160 192430 146 192400
11 16.2 4.94 348 157.8 176 192431 161 192401
12 17.6 5.36 378 171.5 192 192432 175 192402
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.3 0.09 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-23
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120556
934182
934232
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TD-1250 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-24 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-1250 1 stage, S.G. = 1
0
10
20
30
40
50
60
70
4
8
12
16
20
24
0 500 1000 1500 2000 2500
Ft
M
Head
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
ENGINEERING DATA TD-150 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
58 HP
50 HZ 60 HZ
1/2 IN
12.69MM
44 HP
70 HP
90 HP 75 HP
Pump Performance Curve for TD-150 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
37 HP
0
5
10
15
20
25
Ft
2
4
6
8
M
Head
0 50 100 150 200 250 300 350
0%
10%
20%
30%
40%
50%
BPD
10 20 30 40 50
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
0.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TD-150 50 HZ
Pump Performance Curve for TD-150 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
5-1/2 IN
139.7 MM
4 IN 1/2 IN
101.60MM 12.69MM
60 HZ 50 HZ
8000 PSI 90 HP 75 HP
5000 PSI 44 HP 37 HP
6000 PSI 70 HP 58 HP
0
1
2
3
4
5
M
5
10
15
Ft
Head
0 10 20 30 40
0%
10%
20%
30%
40%
50%
M3/DAY
50 100 150 200 250
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.1
0.2
0.2
0.3
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 19 150701 19 150691 17 170791
2 3.5 1.07 74 33.6 40 150702 40 150692 35 170792
3 4.9 1.49 105 47.6 60 150703 60 150693 54 170793
4 6.3 1.92 135 61.2 81 150704 81 150694 73 170794
5 7.8 2.38 166 75.3 102 150705 93 170795
6 9.2 2.80 196 88.9 122 150706 111 170796
7 10.6 3.23 226 102.5 143 150707 131 170797
8 12 3.66 257 116.6 164 150708 149 170798
9 13.4 4.08 287 130.2 184 150709 169 170799
10 14.8 4.51 318 144.2 205 150710 187 170612
11 16.2 4.94 348 157.9 226 150711 207 170801
12 17.6 5.36 378 171.5 247 150712 225 170802
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.23 0.07 0.77 0.35
Pump to Pump Coupling - FLT
0.19
0.07 0.72 0.33
Pump to Pump Coupling - CMP 0.19 0.07 0.72 0.33
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
TD-150 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
1008556
1008556
100572
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-150 1 stage, S.G. = 1
0
5
10
15
20
25
30
35
40
45
Ft
2
4
6
8
10
12
14
M
Head
0 50 100 150 200 250 300 350 400 450 500
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
10 20 30 40 50 60 70
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-25
104 HP
Pump Performance Curve for TD-1750 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
11/16 IN
17.46MM
125 HP
200 HP
255 HP 213 HP
ENGINEERING DATA TD-1750 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
167 HP
0
5
10
15
20
25
30
35
Ft
2
4
6
8
10
M
Head
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000
0%
10%
20%
30%
40%
50%
60%
70%
BPD
50 100 150 200 250 300 350 400 450
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.3
0.5
0.8
1.0
1.3
1.5
1.8
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-26 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
8000 PSI 255 HP 213 HP
5000 PSI 125 HP 104 HP
6000 PSI 200 HP 167 HP
11/16 IN
101.60MM 17.46MM
60 HZ
5-1/2 IN
139.7 MM
4 IN
Pump Performance Curve for TD-1750 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TD-1750 50 HZ
0
1
2
3
4
5
6
M
5
10
15
20
Ft
Head
0 50 100 150 200 250 300 350 400
0%
13%
25%
38%
50%
63%
75%
M3/DAY
250 500 750 1000 1250 1500 1750 2000 2250 2500
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 8 939801 7 130181 8 110651 7 130201
2 3.5 1.07 74 33.6 16 939819 15 130182 16 110652 15 130202
3 4.9 1.49 105 47.6 25 939827 24 130183 25 110653 24 130203
4 6.3 1.92 135 61.2 33 939835 32 130184 33 110654 32 130204
5 7.8 2.38 166 75.3 41 939868 41 130185 41 110655 41 130205
6 9.2 2.80 196 88.9 50 939876 49 130186 50 110656 49 130206
7 10.6 3.23 226 102.5 58 939884 57 130187 58 110657 57 130207
8 12 3.66 257 116.6 67 939892 66 130188 67 110658 66 130208
9 13.4 4.08 287 130.2 75 939900 74 130189 75 110659 74 130209
10 14.8 4.51 318 144.2 84 939918 83 130190 84 110660 83 130210
11 16.2 4.94 348 157.8 92 939926 91 130191 92 110661 91 130211
12 17.6 5.36 378 171.5 100 939934 100 130192 100 110662 100 130212
13 19 5.79 408 185.1 108 939942 108 110663
14 20.4 6.22 438 198.7 116 939959 116 110664
15 21.8 6.64 468 212.3 125 939967 125 110665
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-27
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120556
934182
934232
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TD-1750 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-28 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-1750 1 stage, S.G. = 1
0
10
20
30
40
50
Ft
4
8
12
16
M
Head
0 500 1000 1500 2000 2500 3000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300 400 500
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-29
104 HP
Pump Performance Curve for TD-2200 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
11/16 IN
17.46MM
125 HP
200 HP
255 HP 213 HP
ENGINEERING DATA TD-2200 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
167 HP
0
5
10
15
20
25
30
35
Ft
2
4
6
8
10
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000
0%
10%
20%
30%
40%
50%
60%
70%
BPD
100 200 300 400 500 600
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.3
0.5
0.8
1.0
1.3
1.5
1.8
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-30 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
8000 PSI 255 HP 213 HP
5000 PSI 125 HP 104 HP
6000 PSI 200 HP 167 HP
11/16 IN
101.60MM 17.46MM
60 HZ
5-1/2 IN
139.7 MM
4 IN
Pump Performance Curve for TD-2200 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TD-2200 50 HZ
0
1
2
3
4
5
6
7
M
5
10
15
20
Ft
Head
0 50 100 150 200 250 300 350 400 450 500 550
0%
13%
25%
38%
50%
63%
75%
88%
M3/DAY
250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
0.9
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 8 130981 8 132941 7 132961
2 3.5 1.07 74 33.6 16 130982 15 131782 16 132942 15 132962
3 4.9 1.49 105 47.6 25 130983 24 131783 25 132943 24 132963
4 6.3 1.92 135 61.2 33 130984 33 132944 32 132964
5 7.8 2.38 166 75.3 41 130985 41 131785 41 132945 41 132965
6 9.2 2.80 196 88.9 50 130986 49 131786 50 132946 49 132966
7 10.6 3.23 226 102.5 58 130987 57 131787 58 132947 57 132967
8 12 3.66 257 116.6 67 130988 66 131788 67 132948 66 132968
9 13.4 4.08 287 130.2 75 130989 74 131789 75 132949 74 132969
10 14.8 4.51 318 144.2 84 130990 83 131790 84 132950 83 132970
11 16.2 4.94 348 157.8 92 130991 91 131791 92 132951 91 132971
12 17.6 5.36 378 171.5 100 130992 100 131792 100 132952 100 132972
13 19 5.79 408 185.1 108 130993 108 132953
14 20.4 6.22 438 198.7 116 130994 116 132954
15 21.8 6.64 468 212.3 125 130995 125 132955
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-31
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120556
934182
934232
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TD-2200 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-32 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-2200 1 stage, S.G. = 1
0
10
20
30
40
50
60
Ft
4
8
12
16
20
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300 400 500 600 700
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
ENGINEERING DATA TD-150 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
125HP
50 HZ 60 HZ
1/2 IN
12.69MM
94HP
150HP
192HP 160HP
Pump Performance Curve for TD-300 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
78HP
0
5
10
15
20
25
Ft
2
4
6
8
M
Head
0 50 100 150 200 250 300 350 400 450 500 550 600 650
0%
10%
20%
30%
40%
50%
BPD
10 20 30 40 50 60 70 80 90 100
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
0.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TD-150 50 HZ
Pump Performance Curve for TD-300 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
5-1/2 IN
139.7 MM
4 IN 1/2 IN
101.60MM 12.69MM
60 HZ 50 HZ
8000 PSI 192HP 160HP
5000 PSI 94HP 78HP
6000 PSI 150HP 125HP
0
1
2
3
4
5
M
5
10
15
Ft
Head
0 10 20 30 40 50 60 70 80
0%
20%
40%
60%
80%
100%
M3/DAY
50 100 150 200 250 300 350 400 450 500
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.1
0.2
0.2
0.3
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 15 130881 14 130901 15 130921 13 130941
2 3.5 1.07 74 33.6 32 130882 31 130902 31 130922 29 130942
3 4.9 1.49 105 47.6 49 130883 48 130903 47 130923 45 130943
4 6.3 1.92 135 61.2 66 130884 65 130904 63 130924 61 130944
5 7.8 2.38 166 75.3 83 130885 82 130905 78 130925 76 130945
6 9.2 2.80 196 88.9 100 130886 98 130906 93 130926 91 130946
7 10.6 3.23 226 102.5 117 130887 109 130927
8 12 3.66 257 116.6 133 130888 125 130928
9 13.4 4.08 287 130.2 150 130889 140 130929
10 14.8 4.51 318 144.2 167 130890 156 130930
11 16.2 4.94 348 157.9 184 130891 171 130931
12 17.6 5.36 378 171.5 201 130892 187 130932
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.23 0.07 0.77 0.35
Pump to Pump Coupling - FLT
0.19
0.07 0.72 0.33
Pump to Pump Coupling - CMP 0.19 0.07 0.72 0.33
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
TD-300 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120555
926477
934281
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-300 1 stage, S.G. = 1
0
5
10
15
20
25
30
35
40
45
Ft
2
4
6
8
10
12
14
M
Head
0 100 200 300 400 500 600 700 800
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
25 50 75 100 125
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-33
213 HP
Pump Performance Curve for TD-3000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
7/8 IN
22.22MM
256 HP
410 HP
522 HP 435 HP
ENGINEERING DATA TD-3000 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
342 HP
0
5
10
15
20
25
30
Ft
2
4
6
8
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
0%
15%
30%
45%
60%
75%
90%
BPD
100 200 300 400 500 600 700
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.5
1.0
1.5
2.0
2.5
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-34 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
8000 PSI 522 HP 435 HP
5000 PSI 256 HP 213 HP
6000 PSI 410 HP 342 HP
7/8 IN
101.60MM 22.22MM
60 HZ
5-1/2 IN
139.7 MM
4 IN
Pump Performance Curve for TD-3000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TD-3000 50 HZ
0
1
2
3
4
5
M
5
10
15
Ft
Head
0 100 200 300 400 500 600 700
0%
15%
30%
45%
60%
75%
M3/DAY
500 1000 1500 2000 2500 3000 3500 4000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.3
0.5
0.8
1.0
1.3
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 6 936260 6 130241 6 110671 6 130261
2 3.5 1.07 74 33.6 14 936278 14 130242 14 110672 14 130262
3 4.9 1.49 105 47.6 21 936286 21 130243 21 110673 21 130263
4 6.3 1.92 135 61.2 29 936294 29 130244 29 110674 29 130264
5 7.8 2.38 166 75.3 36 936302 36 130245 36 110675 36 130265
6 9.2 2.80 196 88.9 44 936310 44 130246 44 110676 44 130266
7 10.6 3.23 226 102.5 51 936328 51 130247 51 110677 51 130267
8 12 3.66 257 116.6 59 936336 59 130248 59 110678 59 130268
9 13.4 4.08 287 130.2 66 936344 66 130249 66 110679 66 130269
10 14.8 4.51 318 144.2 74 936351 74 130250 74 110680 74 130270
11 16.2 4.94 348 157.8 81 936369 81 130251 81 110681 81 130271
12 17.6 5.36 378 171.5 89 936377 89 130252 89 110682 89 130272
13 19 5.79 408 185.1 96 936385 96 130253 96 110683 96 130273
14 20.4 6.22 438 198.7 104 936393 104 110684 100 130274
15 21.8 6.64 468 212.3 111 936401 111 110685
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-35
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120557
934026
934026
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TD-3000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-36 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-3000 1 stage, S.G. = 1
0
10
20
30
40
50
Ft
4
8
12
16
M
Head
0 1000 2000 3000 4000 5000 6000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
250 500 750
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-37
ENGINEERING DATA TD-4300 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
342 HP
50 HZ 60 HZ
7/8 IN
22.22MM
256 HP
410 HP
522 HP 435 HP
Pump Performance Curve for TD-4300 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
213 HP
0
5
10
15
20
25
30
35
Ft
2
4
6
8
10
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000
0%
10%
20%
30%
40%
50%
60%
70%
BPD
100 200 300 400 500 600 700 800 900 1000 1100
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-38 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TD-4300 50 HZ
Pump Performance Curve for TD-4300 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
5-1/2 IN
139.7 MM
4 IN 7/8 IN
101.60MM 22.22MM
60 HZ 50 HZ
8000 PSI 522 HP 435 HP
5000 PSI 256 HP 213 HP
6000 PSI 410 HP 342 HP
0
1
2
3
4
5
M
5
10
15
Ft
Head
0 100 200 300 400 500 600 700 800 900 1000
0%
15%
30%
45%
60%
75%
M3/DAY
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.5
1.0
1.5
2.0
2.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 4 130391 4 130741 4 132541 4 132561
2 3.5 1.07 74 33.6 6 130392 8 130742 8 132542 8 132562
3 4.9 1.49 105 47.6 13 130393 13 130743 13 132543 13 132563
4 6.3 1.92 135 61.2 18 130394 17 130744 17 132544 17 132564
5 7.8 2.38 166 75.3 22 130395 22 130745 22 132545 22 132565
6 9.2 2.80 196 88.9 27 130396 26 130746 27 132546 26 132566
7 10.6 3.23 226 102.5 31 130397 31 130747 31 132547 31 132567
8 12 3.66 257 116.6 36 130398 35 130748 36 132548 35 132568
9 13.4 4.08 287 130.2 40 130399 40 130749 40 132549 40 132569
10 14.8 4.51 318 144.2 45 130400 45 130750 45 132550 45 132570
11 16.2 4.94 348 157.8 49 130401 49 130751 49 132551 49 132571
12 17.6 5.36 378 171.5 54 130402 54 130752 54 132552 54 132572
13 19 5.79 408 185.1 59 130403 58 130753 59 132553 58 132573
14 20.4 6.22 438 198.7 63 130404 63 130754 63 132554 63 132574
15 21.8 6.64 468 212.3 68 130405 68 130755 68 132555 68 132575
Feet Meters Lbs. Kgs.
Bolt on Head (2 7/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-39
TD-4300 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
132160
120557
934026
934026
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-40 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-4300 1 stage, S.G. = 1
0
10
20
30
40
50
Ft
4
8
12
16
M
Head
0 1000 2000 3000 4000 5000 6000 7000 8000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
250 500 750 1000 1250
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9
78 HP
Pump Performance Curve for TD-460 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
ENGINEERING DATA TD-460 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
125 HP
0
5
10
15
20
25
30
35
Ft
2
4
6
8
10
M
Head
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
0%
10%
20%
30%
40%
50%
60%
70%
BPD
10 20 30 40 50 60 70 80 90 100 110
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
8000 PSI 192 HP 160 HP
5000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
5/8 IN
101.60MM 15.88MM
60 HZ
5-1/2 IN
139.7 MM
4 IN
Pump Performance Curve for TD-460 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TD-460 50 HZ
0
2
4
6
8
10
12
M
5
10
15
20
25
30
35
40
Ft
Head
0 10 20 30 40 50 60 70 80 90 100
0%
10%
20%
30%
40%
50%
60%
M3/DAY
50 100 150 200 250 300 350 400 450 500 550 600
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.1
0.2
0.2
0.3
0.3
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 16 160401 15 160381 15 160551 14 160571
2 3.5 1.07 74 33.6 34 160402 33 160382 32 160552 31 160572
3 4.9 1.49 105 47.6 52 160403 50 160383 48 160553 47 160573
4 6.3 1.92 135 61.2 69 160404 68 160384 65 160554 64 160574
5 7.8 2.38 166 75.3 87 160405 86 160385 81 160555 79 160575
6 9.2 2.80 196 88.9 105 160406 100 160386 97 160556 95 160576
7 10.6 3.23 226 102.5 123 160407 113 160557
8 12 3.66 257 116.6 140 160408 129 160558
9 13.4 4.08 287 130.2 158 160409 146 160559
10 14.8 4.51 318 144.2 176 160410 162 160560
11 16.2 4.94 348 157.9 194 160411 179 160561
12 17.6 5.36 378 171.5 211 160412 195 160562
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.23 0.07 1.07 0.5
Pump to Pump Coupling - FLT
0.19 0.06
0.65
0.3
Pump to Pump Coupling - CMP 0.22 0.07 0.65 0.3
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120555
926477
934281 934291
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TD-460 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-460 1 stage, S.G. = 1
0
10
20
30
40
50
60
Ft
4
8
12
16
20
M
Head
0 100 200 300 400 500 600 700 800 900
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
25 50 75 100 125
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-41
ENGINEERING DATA TD-6000 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
342 HP
50 HZ 60 HZ
7/8 IN
22.22MM
256 HP
410 HP
522 HP 435 HP
Pump Performance Curve for TD-6000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
213 HP
0
5
10
15
20
25
Ft
2
4
6
8
M
Head
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
0%
20%
40%
60%
80%
100%
BPD
250 500 750 1000 1250
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
4.0
5.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 101.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-42 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TD-6000 50 HZ
Pump Performance Curve for TD-6000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
5-1/2 IN
139.7 MM
4 IN 7/8 IN
101.60MM 22.22MM
60 HZ 50 HZ
8000 PSI 522 HP 435 HP
5000 PSI 256 HP 213 HP
6000 PSI 410 HP 342 HP
0
1
2
3
4
5
6
M
5
10
15
20
Ft
Head
0 250 500 750 1000 1250
0%
13%
25%
38%
50%
63%
75%
M3/DAY
1000 2000 3000 4000 5000 6000 7000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.3
0.5
0.8
1.0
1.3
1.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 4 131901 4 131921 4 132581 4 132601
2 3.5 1.07 74 33.6 8 131902 8 131922 8 132582 8 132602
3 4.9 1.49 105 47.6 13 131903 13 131923 13 132583 13 132603
4 6.3 1.92 135 61.2 17 131904 17 131924 17 132584 17 132604
5 7.8 2.38 166 75.3 22 131905 22 131925 22 132585 22 132605
6 9.2 2.80 196 88.9 27 131906 26 131926 27 132586 26 132606
7 10.6 3.23 226 102.5 31 131907 31 131927 31 132587 31 132607
8 12 3.66 257 116.6 36 131908 35 131928 36 132588 35 132608
9 13.4 4.08 287 130.2 40 131909 40 131929 40 132589 40 132609
10 14.8 4.51 318 144.2 45 131910 45 131930 45 132590 45 132610
11 16.2 4.94 348 157.8 49 131911 49 131931 49 132591 49 132611
12 17.6 5.36 378 171.5 54 131912 54 131932 54 132592 54 132612
13 19 5.79 408 185.1 59 131913 58 131933 59 132593 58 132613
14 20.4 6.22 438 198.7 63 131914 63 131934 63 132594 63 132614
15 21.8 6.64 468 212.3 68 131915 68 131935 68 132595 68 132615
Feet Meters Lbs. Kgs.
Bolt on Head (2 7/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-43
TD-6000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
132160
120557
934026
934026
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-44 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-6000 1 stage, S.G. = 1
0
10
20
30
40
50
Ft
4
8
12
16
M
Head
0 2000 4000 6000 8000 10000 12000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
500 1000 1500
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13
78 HP
Pump Performance Curve for TD-650 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
ENGINEERING DATA TD-650 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
125 HP
0
5
10
15
20
25
30
Ft
2
4
6
8
M
Head
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
0%
10%
20%
30%
40%
50%
60%
BPD
25 50 75 100 125 150 175
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
8000 PSI 192 HP 160 HP
5000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
5/8 IN
101.60MM 15.88MM
60 HZ
5-1/2 IN
139.7 MM
4 IN
Pump Performance Curve for TD-650 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TD-650 50 HZ
0
1
2
3
4
5
6
7
M
5
10
15
20
Ft
Head
0 25 50 75 100 125 150
0%
10%
20%
30%
40%
50%
60%
70%
M3/DAY
100 200 300 400 500 600 700 800 900 1000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
0.9
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 18 131141 15 130111 17 118081 14 130121
2 3.5 1.07 74 33.6 37 131142 33 130112 35 118082 31 130122
3 4.9 1.49 105 47.6 56 131143 50 130113 52 118083 47 130123
4 6.3 1.92 135 61.2 76 131144 68 130114 71 118084 64 130124
5 7.8 2.38 166 75.3 95 131145 86 130115 88 118085 79 130125
6 9.2 2.80 196 88.9 114 131146 100 130116 105 118086 91 130126
7 10.6 3.23 226 102.5 133 131147 123 118087
8 12 3.66 257 116.6 153 131148 141 118088
9 13.4 4.08 287 130.2 172 131149 158 118089
10 14.8 4.51 318 144.2 191 131150 176 118090
11 16.2 4.94 348 157.9 210 131151 193 118091
12 17.6 5.36 378 171.5 230 131152 211 118092
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.23 0.07 1.07 0.5
Pump to Pump Coupling - FLT
0.19 0.06
0.65
0.3
Pump to Pump Coupling - CMP 0.22 0.07 0.65 0.3
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120555
926477
934281
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TD-650 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-16 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-650 1 stage, S.G. = 1
0
10
20
30
40
50
60
Ft
4
8
12
16
20
M
Head
0 200 400 600 800 1000 1200 1400
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
50 100 150 200
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17
ENGINEERING DATA TD-850 60 HZ
139.7 MM
5-1/2 IN
8000 PSI
6000 PSI
5000 PSI
101.60MM
4 IN
125 HP
50 HZ 60 HZ
5/8 IN
15.88MM
94 HP
150 HP
192 HP 160 HP
Pump Performance Curve for TD-850 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
78 HP
0
5
10
15
20
25
30
Ft
2
4
6
8
M
Head
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
0%
10%
20%
30%
40%
50%
60%
BPD
25 50 75 100 125 150 175 200 225
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.2
0.3
0.4
0.5
0.6
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 4 / 102 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-18 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TD-850 50 HZ
Pump Performance Curve for TD-850 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
5-1/2 IN
139.7 MM
4 IN 5/8 IN
101.60MM 15.88MM
60 HZ 50 HZ
8000 PSI 192 HP 160 HP
5000 PSI 94 HP 78 HP
6000 PSI 150 HP 125 HP
0
1
2
3
4
5
6
7
M
5
10
15
20
Ft
Head
0 25 50 75 100 125 150 175
0%
10%
20%
30%
40%
50%
60%
70%
M3/DAY
100 200 300 400 500 600 700 800 900 1000 1100
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.1
0.3
0.4
0.5
0.6
0.8
0.9
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 16 123501 15 130591 15 123521 14 130601
2 3.5 1.07 74 33.6 34 123502 33 130592 32 123522 31 130602
3 4.9 1.49 105 47.6 52 123503 50 130593 48 123523 47 130603
4 6.3 1.92 135 61.2 69 123504 68 130594 65 123524 64 130604
5 7.8 2.38 166 75.3 87 123505 86 130595 81 123525 79 130605
6 9.2 2.80 196 88.9 105 123506 100 130596 97 123526 91 130606
7 10.6 3.23 226 102.5 123 123507 113 123527
8 12 3.66 257 116.6 140 123508 129 123528
9 13.4 4.08 287 130.2 158 123509 145 123529
10 14.8 4.51 318 144.2 176 123510 162 123530
11 16.2 4.94 348 157.9 194 123511 178 123531
12 17.6 5.36 378 171.5 211 123512 194 123532
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5
Coupling for Intake or GS 0.23 0.07 1.07 0.5
Pump to Pump Coupling - FLT
0.19 0.06
0.65
0.3
Pump to Pump Coupling - CMP 0.22 0.07 0.65 0.3
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19
TD-850 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120555
926477
934281
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-20 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TD-850 1 stage, S.G. = 1
0
10
20
30
40
50
60
Ft
4
8
12
16
20
M
Head
0 200 400 600 800 1000 1200 1400 1600
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
50 100 150 200 250
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.125 / 130.2 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
313 HP
Pump Performance Curve for TG-4000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1 IN
25.40MM
375 HP
600 HP
765 HP 638 HP
ENGINEERING DATA TG-4000 60 HZ
168.3 MM
6-5/8 IN
6000 PSI
6000 PSI
5000 PSI
130.18MM
5.13 IN
500 HP
0
10
20
30
40
50
60
Ft
4
8
12
16
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500
0%
10%
20%
30%
40%
50%
60%
BPD
100 200 300 400 500 600 700 800 900 1000
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
4.0
5.0
6.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.125 / 130.2 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
6000 PSI 765 HP 638 HP
5000 PSI 375 HP 313 HP
6000 PSI 600 HP 500 HP
1 IN
130.18MM 25.40MM
60 HZ
6-5/8 IN
168.3 MM
5.13 IN
Pump Performance Curve for TG-4000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TG-4000 50 HZ
0
2
4
6
8
10
12
M
5
10
15
20
25
30
35
40
Ft
Head
0 100 200 300 400 500 600 700 800 900
0%
10%
20%
30%
40%
50%
60%
M3/DAY
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
0.5
1.0
1.5
2.0
2.5
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 77 34.9 5 184021 5 131161 5 111461 5 131221
2 3.5 1.07 145 65.8 12 184022 11 131162 12 111462 11 131222
3 4.9 1.49 213 96.6 18 184023 18 131163 18 111463 18 131223
4 6.3 1.92 272 123.4 25 184024 25 131164 25 131224
5 7.8 2.38 340 154.2 32 184025 32 131165 32 111465 32 131225
6 9.2 2.80 407 184.6 39 184026 38 131166 39 111466 38 131226
7 10.6 3.23 467 211.8 46 184027 45 131167 46 111467 45 131227
8 12 3.66 535 242.7 52 184028 52 131168 52 111468 52 131228
9 13.4 4.08 602 273.1 59 184029 59 131169 59 111469 59 131229
10 14.8 4.51 662 300.3 66 184030 65 131170 66 111470 65 131230
11 16.2 4.94 730 331.1 73 184031 73 131171 73 111471 73 131231
12 17.6 5.36 789 357.9 79 184032 79 131172 79 111472 79 131232
13 19 5.79 857 388.7 86 184033 86 131173 86 111473 86 131233
14 20.4 6.22 924 419.1 93 184034 92 131174 93 111474 92 131234
15 21.8 6.64 984 446.3 100 184035 100 131175 100 111475 100 131235
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 12 5.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
0.85
0.4
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
123270
1011709
949651
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TG-4000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TG-4000 1 stage, S.G. = 1
0
20
40
60
80
100
Ft
5
10
15
20
25
30
35
M
Head
0 1000 2000 3000 4000 5000 6000 7000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
250 500 750 1000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-29
ENGINEERING DATA TE-11000 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
849 HP
50 HZ 60 HZ
1-11/16
42.86MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TE-11000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
10
20
30
40
50
Ft
4
8
12
16
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000
0%
15%
30%
45%
60%
75%
BPD
500 1000 1500 2000 2500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.0
4.0
6.0
8.0
10.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-30 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TE-11000 50 HZ
Pump Performance Curve for TE-11000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-3/8 IN 1-11/16
136.55MM 42.86MM
60 HZ 50 HZ
6000 PSI 1300 HP 1083 HP
6000 PSI 637 HP 531 HP
6000 PSI 1019 HP 849 HP
0
5
10
M
10
20
30
40
Ft
Head
0 250 500 750 1000 1250 1500 1750 2000
0%
25%
50%
M3/DAY
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 116 52.6 3 138171 3 138191 3 138211 3 138231
2 4 1.22 186 84.4 7 138172 7 138192 7 138212 7 138232
3 5.5 1.68 245 111.1 10 138173 10 138193 10 138213 10 138233
4 7 2.13 314 142.4 14 138174 14 138194 14 138214 14 138234
5 8.5 2.59 384 174.2 18 138175 18 138195 18 138215 18 138235
6 10 3.05 453 205.5 22 138176 22 138196 22 138216 22 138236
7 11.5 3.51 523 237.2 26 138177 26 138197 26 138217 26 138237
8 13 3.96 582 264.0 29 138178 29 138198 29 138218 29 138238
9 14.5 4.42 652 295.7 33 138179 33 138199 33 138219 33 138239
10 16 4.88 721 327.0 37 138180 37 138200 37 138220 37 138240
11 17.5 5.33 791 358.8 41 138181 41 138201 41 138221 41 138241
12 19 5.79 850 385.6 44 138182 44 138202 44 138222 44 138242
13 20.5 6.25 920 417.3 48 138183 48 138203 48 138223 48 138243
14 22 6.71 989 448.6 52 138184 52 138204 52 138224 52 138244
15 23.5 7.16 1059 480.4 56 138185 56 138205 56 138225 56 138245
Feet Meters Lbs. Kgs.
Bolt on Head (3 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.5 0.7
Pump to Pump Coupling - FLT
0.2 0.06
1.69
0.8
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-31
TE-11000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
952572
952572
123247
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-32 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-11000 1 stage, S.G. = 1
0
20
40
60
80
100
Ft
5
10
15
20
25
30
35
M
Head
0 5000 10000 15000 20000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
ENGINEERING DATA TE-1500 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
342 HP
50 HZ 60 HZ
7/8 IN
22.22MM
256 HP
410 HP
522 HP 435 HP
Pump Performance Curve for TE-1500 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
213 HP
0
20
40
60
Ft
5
10
15
20
M
Head
0 400 800 1200 1600 2000 2400 2800
0%
20%
40%
60%
Efficiency
Power
BPD
100 200 300 400
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TE-1500 50 HZ
Pump Performance Curve for TE-1500 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-3/8 IN 7/8 IN
136.55MM 22.22MM
60 HZ 50 HZ
6000 PSI 522 HP 435 HP
6000 PSI 256 HP 213 HP
6000 PSI 410 HP 342 HP
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 50 100 150 200 250 300 350
0%
20%
40%
60%
M3/DAY
250 500 750 1000 1250 1500 1750 2000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 117 53.1 7 138631 7 138461 7 138671 7 138691
2 4 1.22 178 80.7 14 138632 14 138462 14 138672 14 138692
3 5.5 1.68 245 111.1 22 138633 22 138463 22 138673 22 138693
4 7 2.13 312 141.5 30 138634 30 138464 30 138674 30 138694
5 8.5 2.59 373 169.2 37 138635 37 138465 37 138675 37 138695
6 10 3.05 440 199.6 45 138636 45 138466 45 138676 45 138696
7 11.5 3.51 502 227.7 52 138637 52 138467 52 138677 52 138697
8 13 3.96 569 258.1 60 138638 60 138468 60 138678 60 138698
9 14.5 4.42 635 288.0 68 138639 68 138469 68 138679 68 138699
10 16 4.88 697 316.2 78 138640 75 138470 75 138680 75 138700
11 17.5 5.33 764 346.5 83 138641 83 138471 83 138681 83 138701
12 19 5.79 825 374.2 90 138642 90 138472 90 138682 90 138702
13 20.5 6.25 892 404.6 98 138643 98 138473 98 138683 98 138703
14 22 6.71 959 435.0 106 138644 106 138684
15 23.5 7.16 1021 463.1 113 138645 113 138685
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 12 5.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
0.85
0.4
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
TE-1500 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
120557
120557
949388
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-1500 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
Ft
5
10
15
20
25
30
35
40
45
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300 400 500 600
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
ENGINEERING DATA TE-2700 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
342 HP
50 HZ 60 HZ
7/8 IN
22.22MM
256 HP
410 HP
522 HP 435 HP
Pump Performance Curve for TE-2700 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
213 HP
0
20
40
60
Ft
5
10
15
20
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500
0%
20%
40%
60%
Power
BPD
100 200 300 400 500 600 700
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TE-2700 50 HZ
Pump Performance Curve for TE-2700 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-3/8 IN 7/8 IN
136.55MM 22.22MM
60 HZ 50 HZ
6000 PSI 522 HP 435 HP
6000 PSI 256 HP 213 HP
6000 PSI 410 HP 342 HP
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 50 100 150 200 250 300 350 400 450 500 550 600
0%
20%
40%
60%
M3/DAY
250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 117 53.1 7 138761 7 138741 7 138821 7 138801
2 4 1.22 178 80.7 14 138762 14 138742 14 138822 14 138802
3 5.5 1.68 245 111.1 22 138763 22 138743 22 138823 22 138803
4 7 2.13 312 141.5 30 138764 30 138744 30 138824 30 138804
5 8.5 2.59 373 169.2 37 138765 37 138745 37 138825 37 138805
6 10 3.05 440 199.6 45 138766 45 138746 45 138826 45 138806
7 11.5 3.51 502 227.7 52 138767 52 138747 52 138827 52 138807
8 13 3.96 569 258.1 60 138768 60 138748 60 138828 60 138808
9 14.5 4.42 635 288.0 68 138769 68 138749 68 138829 68 138809
10 16 4.88 697 316.2 75 138770 75 138750 75 138830 75 138810
11 17.5 5.33 764 346.5 83 138771 83 138751 83 138831 83 138811
12 19 5.79 825 374.2 90 138772 90 138752 90 138832 90 138812
13 20.5 6.25 892 404.6 98 138773 98 138753 98 138833 98 138813
14 22 6.71 959 435.0 106 138774 106 138834
15 23.5 7.16 1021 463.1 113 138775 113 138835
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.2
0.5
Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
TE-2700 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
120557
120557
949388
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-2700 1 stage, S.G. = 1
0
20
40
60
80
100
120
Ft
5
10
15
20
25
30
35
40
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
100 200 300 400 500 600 700
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9
ENGINEERING DATA TE-3300 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
342 HP
50 HZ 60 HZ
7/8 IN
22.22MM
256 HP
410 HP
522 HP 435 HP
Pump Performance Curve for TE-3300 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
213 HP
0
10
20
30
40
50
60
70
Ft
4
8
12
16
20
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
0%
10%
20%
30%
40%
50%
60%
70%
Power
BPD
100 200 300 400 500 600 700 800 900
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TE-3300 50 HZ
Pump Performance Curve for TE-3300 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-3/8 IN 7/8 IN
136.55MM 22.22MM
60 HZ 50 HZ
6000 PSI 522 HP 435 HP
6000 PSI 256 HP 213 HP
6000 PSI 410 HP 342 HP
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 100 200 300 400 500 600 700 800
0%
20%
40%
60%
M3/DAY
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 117 53.1 7 158481 7 158061 7 158501 7 158521
2 4 1.22 178 80.7 14 158482 14 158062 14 158502 14 158522
3 5.5 1.68 245 111.1 22 158483 22 158063 22 158503 22 158523
4 7 2.13 312 141.5 30 158484 30 158064 30 158504 30 158524
5 8.5 2.59 373 169.2 37 158485 37 158065 37 158505 37 158525
6 10 3.05 440 199.6 45 158486 45 158066 45 158506 45 158526
7 11.5 3.51 502 227.7 52 158487 52 158067 52 158507 52 158527
8 13 3.96 569 258.1 60 158488 60 158068 60 158508 60 158528
9 14.5 4.42 635 288.0 68 158489 68 158069 68 158509 68 158529
10 16 4.88 697 316.2 75 158490 75 158070 75 158510 75 158530
11 17.5 5.33 764 346.5 83 158491 83 158071 83 158511 83 158531
12 19 5.79 825 374.2 90 158492 90 158072 90 158512 90 158532
13 20.5 6.25 892 404.6 98 158493 98 158073 98 158513 98 158533
14 22 6.71 959 435.0 106 158494 106 158514
15 23.5 7.16 1021 463.1 113 158495 113 158515
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.2
0.5
Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
TE-3300 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
120557
120577
138028
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-3300 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
Ft
5
10
15
20
25
30
35
40
45
M
Head
0 1000 2000 3000 4000 5000 6000 7000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
250 500 750 1000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13
ENGINEERING DATA TE-4200 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
500 HP
50 HZ 60 HZ
1 IN
25.40MM
375 HP
600 HP
765 HP 638 HP
Pump Performance Curve for TE-4200 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
313 HP
0
10
20
30
40
50
60
70
Ft
4
8
12
16
20
M
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500
0%
10%
20%
30%
40%
50%
60%
70%
Power
BPD
100 200 300 400 500 600 700 800 900 1000
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TE-4200 50 HZ
Pump Performance Curve for TE-4200 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-3/8 IN 1 IN
136.55MM 25.40MM
60 HZ 50 HZ
6000 PSI 765 HP 638 HP
6000 PSI 375 HP 313 HP
6000 PSI 600 HP 500 HP
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 100 200 300 400 500 600 700 800 900
0%
20%
40%
60%
M3/DAY
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
1.0
2.0
3.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 115 52.2 5 158651 5 158631 5 158821 5 158671
2 4 1.22 180 81.6 11 158652 11 158632 11 158822 11 158672
3 5.5 1.68 245 111.1 17 158653 17 158633 17 158823 17 158673
4 7 2.13 311 141.1 23 158654 23 158634 23 158824 23 158674
5 8.5 2.59 376 170.6 29 158655 29 158635 29 158825 29 158675
6 10 3.05 441 200.0 35 158656 35 158636 35 158826 35 158676
7 11.5 3.51 507 230.0 41 158657 41 158637 41 158827 41 158677
8 13 3.96 572 259.5 47 158658 47 158638 47 158828 47 158678
9 14.5 4.42 637 288.9 53 158659 53 158639 53 158829 53 158679
10 16 4.88 703 318.9 59 158660 59 158640 59 158830 59 158680
11 17.5 5.33 768 348.4 65 158661 65 158641 65 158831 65 158681
12 19 5.79 833 377.8 71 158662 71 158642 71 158832 71 158682
13 20.5 6.25 899 407.8 77 158663 77 158643 77 158833 77 158683
14 22 6.71 964 437.3 83 158664 83 158644 83 158834 83 158684
15 23.5 7.16 1029 466.7 89 158665 89 158645 89 158835 89 158685
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.2
0.5
Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15
TE-4200 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
123270
123270
138028
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-16 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-4200 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
Ft
5
10
15
20
25
30
35
40
45
M
Head
0 1000 2000 3000 4000 5000 6000 7000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
250 500 750 1000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17
313 HP
Pump Performance Curve for TE-5500 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1 IN
25.40MM
375 HP
600 HP
765 HP 638 HP
ENGINEERING DATA TE-4200 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
500 HP
0
20
40
60
80
Ft
5
10
15
20
25
M
Head
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
0%
20%
40%
60%
80%
Power
BPD
250 500 750 1000 1250 1500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.0
4.0
6.0
8.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-18 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
6000 PSI 765 HP 638 HP
6000 PSI 375 HP 313 HP
6000 PSI 600 HP 500 HP
1 IN
136.55MM 25.44MM
60 HZ
7 IN
177.8 MM
5-3/8 IN
Pump Performance Curve for TE-5500 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TE-4200 50 HZ
0
5
10
M
10
20
30
40
Ft
Head
0 250 500 750 1000 1250
0%
25%
50%
M3/DAY
1000 2000 3000 4000 5000 6000 7000 8000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 115 52.2 5 138351 5 138331 5 138371 5 138391
2 4 1.22 180 81.6 11 138352 11 138332 11 138372 11 138392
3 5.5 1.68 245 111.1 17 138353 17 138333 17 138373 17 138393
4 7 2.13 311 141.1 23 138354 23 138334 23 138374 23 138394
5 8.5 2.59 376 170.6 29 138355 29 138335 29 138375 29 138395
6 10 3.05 441 200.0 35 138356 35 138336 35 138376 35 138396
7 11.5 3.51 507 230.0 41 138357 41 138337 41 138377 41 138397
8 13 3.96 572 259.5 47 138358 47 138338 47 138378 47 138398
9 14.5 4.42 637 288.9 53 138359 53 138339 53 138379 53 138399
10 16 4.88 703 318.9 59 138360 59 138340 59 138380 59 138400
11 17.5 5.33 768 348.4 65 138361 65 138341 65 138381 65 138401
12 19 5.79 833 377.8 71 138362 71 138342 71 138382 71 138402
13 20.5 6.25 899 407.8 77 138363 77 138343 77 138383 77 138403
14 22 6.71 964 437.3 83 138364 83 138344 83 138384 83 138404
15 23.5 7.16 1029 466.7 89 138365 89 138345 89 138385 89 138405
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.2
0.5
Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
123270
123270
949651
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TE-5500 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-20 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-5500 1 stage, S.G. = 1
0
20
40
60
80
100
120
Ft
5
10
15
20
25
30
35
40
M
Head
0 2000 4000 6000 8000 10000 12000 14000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
500 1000 1500 2000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-21
ENGINEERING DATA TE-7000 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
500 HP
50 HZ 60 HZ
1 IN
25.40MM
375 HP
600 HP
765 HP 638 HP
Pump Performance Curve for TE-7000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
313 HP
0
20
40
60
80
Ft
5
10
15
20
25
M
Head
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000
0%
20%
40%
60%
80%
BPD
250 500 750 1000 1250 1500 1750
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.0
4.0
6.0
8.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-22 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TE-7000 50 HZ
Pump Performance Curve for TE-7000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-3/8 IN 1 IN
136.55MM 25.40MM
60 HZ 50 HZ
6000 PSI 765 HP 638 HP
6000 PSI 375 HP 313 HP
6000 PSI 600 HP 500 HP
0
5
10
M
10
20
30
40
Ft
Head
0 250 500 750 1000 1250 1500
0%
25%
50%
M3/DAY
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 115 52.2 5 138271 5 138111 5 138291 5 138311
2 4 1.22 180 81.6 11 138272 11 138112 11 138292 11 138312
3 5.5 1.68 245 111.1 17 138273 17 138113 17 138293 17 138313
4 7 2.13 311 141.1 23 138274 23 138114 23 138294 23 138314
5 8.5 2.59 376 170.6 29 138275 29 138115 29 138295 29 138315
6 10 3.05 441 200.0 35 138276 35 138116 35 138296 35 138316
7 11.5 3.51 507 230.0 41 138277 41 138117 41 138297 41 138317
8 13 3.96 572 259.5 47 138278 47 138118 47 138298 47 138318
9 14.5 4.42 637 288.9 53 138279 53 138119 53 138299 53 138319
10 16 4.88 703 318.9 59 138280 59 138120 59 138300 59 138320
11 17.5 5.33 768 348.4 65 138281 65 138121 65 138301 65 138321
12 19 5.79 833 377.8 71 138282 71 138122 71 138302 71 138322
13 20.5 6.25 899 407.8 77 138283 77 138123 77 138303 77 138323
14 22 6.71 964 437.3 83 138284 83 138124 83 138304 83 138324
15 23.5 7.16 1029 466.7 89 138285 89 138125 89 138305 89 138325
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.2
0.5
Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-23
TE-7000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
123270
123270
949651
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-24 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-7000 1 stage, S.G. = 1
0
20
40
60
80
100
120
Ft
5
10
15
20
25
30
35
40
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
500 1000 1500 2000 2500
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-25
313 HP
Pump Performance Curve for TE-7200 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1 IN
25.40MM
375 HP
600 HP
765 HP 638 HP
ENGINEERING DATA TE-7200 60 HZ
177.8 MM
7 IN
6000 PSI
6000 PSI
6000 PSI
136.55MM
5-3/8 IN
500 HP
0
20
40
60
80
Ft
5
10
15
20
25
M
Head
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000
0%
20%
40%
60%
80%
BPD
250 500 750 1000 1250 1500 1750
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.0
4.0
6.0
8.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.375 / 136.6 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-26 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
6000 PSI 765 HP 638 HP
6000 PSI 375 HP 313 HP
6000 PSI 600 HP 500 HP
1 IN
136.55MM 25.40MM
60 HZ
7 IN
177.8 MM
5-3/8 IN
Pump Performance Curve for TE-7200 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TE-7200 50 HZ
0
5
10
M
10
20
30
40
Ft
Head
0 250 500 750 1000 1250 1500
0%
25%
50%
M3/DAY
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.5 0.76 115 52.2 5 158771 5 158721 5 158791 5 158741
2 4 1.22 180 81.6 11 158772 11 158722 11 158792 11 158742
3 5.5 1.68 245 111.1 17 158773 17 158723 17 158793 17 158743
4 7 2.13 311 141.1 23 158774 23 158724 23 158794 23 158744
5 8.5 2.59 376 170.6 29 158775 29 158725 29 158795 29 158745
6 10 3.05 441 200.0 35 158776 35 158726 35 158796 35 158746
7 11.5 3.51 507 230.0 41 158777 41 158727 41 158797 41 158747
8 13 3.96 572 259.5 47 158778 47 158728 47 158798 47 158748
9 14.5 4.42 637 288.9 53 158779 53 158729 53 158799 53 158749
10 16 4.88 703 318.9 59 158780 59 158730 59 158800 59 158750
11 17.5 5.33 768 348.4 65 158781 65 158731 65 158801 65 158751
12 19 5.79 833 377.8 71 158782 71 158732 71 158802 71 158752
13 20.5 6.25 899 407.8 77 158783 77 158733 77 158803 77 158753
14 22 6.71 964 437.3 83 158784 83 158734 83 158804 83 158754
15 23.5 7.16 1029 466.7 89 158785 89 158735 89 158805 89 158755
Feet Meters Lbs. Kgs.
Bolt on Head (3-1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.22 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.2
0.5
Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-27
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
940510
123270
123270
949651
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TE-7200 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-28 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TE-7200 1 stage, S.G. = 1
0
20
40
60
80
100
120
Ft
5
10
15
20
25
30
35
40
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
500 1000 1500 2000 2500
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.625 / 142.9 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
ENGINEERING DATA TH-15000 60 HZ
177.8 MM
7 IN
3600 PSI
3600 PSI
3000 PSI
142.88MM
5-5/8 IN
849 HP
50 HZ 60 HZ
1-3/16 IN
30.16MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TH-15000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
5
10
15
20
25
30
35
40
45
50
Ft
2
4
6
8
10
12
14
16
18
20
M
Head
0 2500 5000 7500 10000 12500 15000 17500 20000 22500 25000
0%
5%
10%
15%
20%
25%
30%
35%
40%
45%
50%
BPD
500 1000 1500 2000 2500 3000 3500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.625 / 142.9 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TH-15000 50 HZ
Pump Performance Curve for TH-15000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-5/8 IN 1-3/16 IN
142.88MM 30.16MM
60 HZ 50 HZ
3600 PSI 1300 HP 1083 HP
3000 PSI 637 HP 531 HP
3600 PSI 1019 HP 849 HP
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 500 1000 1500 2000 2500 3000 3500
0%
25%
50%
75%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 108 49.0 2 123251
2 3.5 1.07 174 78.9 5 123252 5 123372
3 4.9 1.49 241 109.3 8 123253 8 123373
4 6.3 1.92 307 139.2 11 123254 11 123374
5 7.7 2.35 374 169.6 14 123255 14 123375
6 9.1 2.77 440 199.5 17 123256 17 123376
7 10.5 3.20 506 229.5 20 123257 20 123377
8 11.9 3.63 573 259.9 23 123258 23 123378
9 13.3 4.05 639 289.8 26 123259 26 123379
10 14.7 4.48 706 320.2 29 123260 29 123380
11 16.1 4.91 772 350.1 32 123261 32 123381
12 17.5 5.33 839 380.5 36 123262 36 123382
13 18.9 5.76 905 410.4 39 123263 39 123383
14 20.3 6.19 994 450.8 42 123264 42 123384
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.5 0.7
Pump to Pump Coupling - FLT
0.2 0.06
1.69
0.8
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
TH-15000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
123189
123270
123270
949651
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TH-15000 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
Ft
5
10
15
20
25
30
35
40
45
M
Head
0 5000 10000 15000 20000 25000 30000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.625 / 142.9 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9
ENGINEERING DATA TH-20000 60 HZ
177.8 MM
7 IN
3600 PSI
3600 PSI
3000 PSI
142.88MM
5-5/8 IN
849 HP
50 HZ 60 HZ
1-3/16 IN
30.16MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TH-20000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
5
10
15
20
25
30
35
40
45
50
Ft
2
4
6
8
10
12
14
16
18
20
M
Head
0 2500 5000 7500 10000 12500 15000 17500 20000 22500 25000 27500 30000
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
BPD
500 1000 1500 2000 2500 3000 3500 4000 4500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 5.625 / 142.9 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TH-20000 50 HZ
Pump Performance Curve for TH-20000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
7 IN
177.8 MM
5-5/8 IN 1-3/16 IN
142.88MM 30.16MM
60 HZ 50 HZ
3600 PSI 1300 HP 1083 HP
3000 PSI 637 HP 531 HP
3600 PSI 1019 HP 849 HP
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 500 1000 1500 2000 2500 3000 3500 4000
0%
25%
50%
75%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000 22500 25000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 108 49.0 2 123351 2 123391
2 3.5 1.07 174 78.9 5 123352 5 123392
3 4.9 1.49 241 109.3 8 123353 8 123393
4 6.3 1.92 307 139.2 11 123354 11 123394
5 7.7 2.35 374 169.6 14 123355 14 123395
6 9.1 2.77 440 199.5 17 123356 17 123396
7 10.5 3.20 506 229.5 20 123357 20 123397
8 11.9 3.63 573 259.9 23 123358 23 123398
9 13.3 4.05 639 289.8 26 123359 26 123399
10 14.7 4.48 706 320.2 29 123360 29 123400
11 16.1 4.91 772 350.1 32 123361 32 123401
12 17.5 5.33 839 380.5 36 123362 36 123402
13 18.9 5.76 905 410.4 39 123363 39 123403
14 20.3 6.19 994 450.8 42 123364 42 123404
Feet Meters Lbs. Kgs.
Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.5 0.7
Pump to Pump Coupling - FLT
0.2 0.06
1.69
0.8
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
TH-20000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
123189
123270
123270
949651
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TH-20000 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
Ft
5
10
15
20
25
30
35
40
45
M
Head
0 5000 10000 15000 20000 25000 30000 35000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000 5000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9
531 HP
Pump Performance Curve for TJ-12000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1-3/16 IN
30.16MM
637 HP
1019 HP
1300 HP 1083 HP
ENGINEERING DATA TJ-12000 60 HZ
219.1 MM
8-5/8 IN
3600 PSI
3600 PSI
3000 PSI
171.45MM
6-3/4 IN
849 HP
0
20
40
60
80
100
Ft
5
10
15
20
25
30
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000
0%
20%
40%
60%
80%
100%
BPD
500 1000 1500 2000 2500 3000 3500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
20.0
25.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
3600 PSI 1300 HP 1083 HP
3000 PSI 637 HP 531 HP
3600 PSI 1019 HP 849 HP
1-3/16 IN
171..45MM 30.16MM
60 HZ
8-5/8 IN
219.1 MM
6-3/4 IN
Pump Performance Curve for TJ-12000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TJ-12000 50 HZ
0
5
10
15
20
M
10
20
30
40
50
60
70
Ft
Head
0 500 1000 1500 2000 2500 3000
0%
25%
50%
75%
100%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
20.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.7 0.82 192 87.1 2 117391 2 118061
2 4 1.22 286 129.7 5 117392 5 118062
3 5.4 1.65 378 171.4 8 117393 8 118063
4 6.8 2.07 472 214.1 11 117394 11 118064
5 8.2 2.50 566 256.7 14 117395 14 118065
6 9.5 2.90 659 298.9 17 117396 17 118066
7 10.9 3.32 751 340.5 20 117397 20 118067
8 12.3 3.75 845 383.2 23 117398 23 118068
9 13.7 4.18 939 425.8 26 117399 26 118069
10 15 4.57 1033 468.5 29 117400 29 118070
11 16.4 5.00 1125 510.2 32 117401 32 118071
12 17.8 5.43 1218 552.4 35 117402 35 118072
13 19.2 5.85 1313 595.4 38 117403 38 118073
14 20.5 6.25 1406 637.6 41 117404 41 118074
15 21.9 6.68 1499 679.8 44 117405 44 118075
Feet Meters Lbs. Kgs.
Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
957647
952572
952572
952572
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TJ-12000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - February, 2009
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TJ-12000 1 stage, S.G. = 1
0
50
100
150
200
Ft
10
20
30
40
50
60
M
Head
0 5000 10000 15000 20000 25000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13
ENGINEERING DATA TJ-20000 60 HZ
219.1 MM
8-5/8 IN
3600 PSI
3600 PSI
3000 PSI
171.45MM
6-3/4 IN
849 HP
50 HZ 60 HZ
1-3/16 IN
30.16MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TJ-20000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
20
40
60
80
100
Ft
5
10
15
20
25
30
M
Head
0 5000 10000 15000 20000 25000 30000
0%
20%
40%
60%
80%
100%
BPD
1000 2000 3000 4000
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
10.0
20.0
30.0
40.0
50.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TJ-20000 50 HZ
Pump Performance Curve for TJ-20000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
8-5/8 IN
219.1 MM
6-3/4 IN 1-3/16 IN
171.45MM 30.16MM
60 HZ 50 HZ
3600 PSI 1300 HP 1083 HP
3000 PSI 637 HP 531 HP
3600 PSI 1019 HP 849 HP
0
5
10
15
20
M
10
20
30
40
50
60
70
Ft
Head
0 500 1000 1500 2000 2500 3000 3500 4000
0%
20%
40%
60%
80%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000 22500 25000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
4.0
8.0
12.0
16.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.7 0.82 182 82.6 2 147471 2 147531
2 4 1.22 263 119.3 5 147472 5 147532
3 5.4 1.65 343 155.6 8 147473 8 147533
4 6.8 2.07 424 192.3 11 147474 11 147534
5 8.2 2.50 504 228.6 14 147475 14 147535
6 9.5 2.90 568 257.6 16 147476 16 147536
7 10.9 3.32 648 293.9 19 147477 19 147537
8 12.3 3.75 729 330.7 22 147478 22 147538
9 13.7 4.18 809 367.0 25 147479 25 147539
10 15 4.57 890 403.7 28 147480 28 147540
11 16.4 5.00 970 440.0 31 147481 31 147541
12 17.8 5.43 1050 476.3 34 147482 34 147542
13 19.2 5.85 1131 513.0 37 147483 37 147543
14 20.5 6.25 1194 541.6 39 147484 39 147544
15 21.9 6.68 1275 578.3 42 147485 42 147545
Feet Meters Lbs. Kgs.
Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15
TJ-20000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
957647
952572
952572
952572
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-16 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TJ-20000 1 stage, S.G. = 1
0
50
100
150
200
Ft
10
20
30
40
50
60
M
Head
0 5000 10000 15000 20000 25000 30000 35000 40000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000 5000 6000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
531 HP
Pump Performance Curve for TJ-7500 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1-3/16 IN
30.16MM
637 HP
1019 HP
1300 HP 1083 HP
ENGINEERING DATA TJ-7500 60 HZ
219.1 MM
8-5/8 IN
3600 PSI
3600 PSI
3000 PSI
171.45MM
6-3/4 IN
849 HP
0
10
20
30
40
50
60
70
80
Ft
4
8
12
16
20
24
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000
0%
10%
20%
30%
40%
50%
60%
70%
80%
BPD
500 1000 1500 2000 2500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
3600 PSI 1300 HP 1083 HP
3000 PSI 637 HP 531 HP
3600 PSI 1019 HP 849 HP
1-3/16 IN
171.45MM 30.16MM
60 HZ
8-5/8 IN
219.1 MM
6-3/4 IN
Pump Performance Curve for TJ-7500 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TJ-7500 50 HZ
0
5
10
15
M
10
20
30
40
50
Ft
Head
0 250 500 750 1000 1250 1500 1750 2000
0%
25%
50%
75%
M3/DAY
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
2.5
5.0
7.5
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.7 0.82 210 95.2 2 117271 2 117841
2 4 1.22 327 148.3 6 117272 6 117842
3 5.4 1.65 419 190.0 9 117273 9 117843
4 6.8 2.07 511 231.7 12 117274 12 117844
5 8.2 2.50 603 273.5 15 117275 15 117845
6 9.5 2.90 714 323.8 19 117276 19 117846
7 10.9 3.32 806 365.5 22 117277 22 117847
8 12.3 3.75 898 407.2 25 117278 25 117848
9 13.7 4.18 1009 457.6 29 117279 29 117849
10 15 4.57 1104 500.7 32 117280 32 117850
11 16.4 5.00 1193 541.0 35 117281 35 117851
12 17.8 5.43 1304 591.4 39 117282 39 117852
13 19.2 5.85 1396 633.1 42 117283 42 117853
14 20.5 6.25 1488 674.8 45 117284 45 117854
15 21.9 6.68 1580 716.5 48 117285 48 117855
Feet Meters Lbs. Kgs.
Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
957647
952572
952572
952572
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TJ-7500 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TJ-7500 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
160
Ft
5
10
15
20
25
30
35
40
45
50
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
500 1000 1500 2000 2500
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
531 HP
Pump Performance Curve for TJ-9000 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1-3/16 IN
30.16MM
637 HP
1019 HP
1300 HP 1083 HP
ENGINEERING DATA TJ-9000 60 HZ
219.1 MM
8-5/8 IN
3600 PSI
3600 PSI
3000 PSI
171.45MM
6-3/4 IN
849 HP
0
20
40
60
80
100
Ft
5
10
15
20
25
30
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000
0%
20%
40%
60%
80%
100%
BPD
500 1000 1500 2000 2500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
4.0
8.0
12.0
16.0
20.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 6.75 / 171.5 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
3600 PSI 1300 HP 1083 HP
3000 PSI 637 HP 531 HP
3600 PSI 1019 HP 849 HP
1-3/16 IN
171.45MM 30.16MM
60 HZ
8-5/8 IN
219.1 MM
6-3/4 IN
Pump Performance Curve for TJ-9000 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TJ-9000 50 HZ
0
5
10
15
20
M
10
20
30
40
50
60
70
Ft
Head
0 250 500 750 1000 1250 1500 1750 2000
0%
25%
50%
75%
100%
M3/DAY
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
20.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.7 0.82 210 95.3 2 117901 2 147291
2 4 1.22 328 148.8 6 117902 6 147292
3 5.4 1.65 421 191.0 9 117903 9 147293
4 6.8 2.07 513 232.7 12 117904 12 147294
5 8.2 2.50 606 274.9 15 117905 15 147295
6 9.5 2.90 718 325.7 19 117906 19 147296
7 10.9 3.32 810 367.4 22 117907 22 147297
8 12.3 3.75 903 409.6 25 117908 25 147298
9 13.7 4.18 1015 460.4 29 117909 29 147299
10 15 4.57 1110 503.5 32 117910 32 147300
11 16.4 5.00 1200 544.3 35 117911 35 147301
12 17.8 5.43 1312 595.1 39 117912 39 147302
13 19.2 5.85 1404 636.9 42 117913 42 147303
14 20.5 6.25 1497 679.0 45 117914 45 147304
15 21.9 6.68 1590 721.2 48 117915 48 147305
Feet Meters Lbs. Kgs.
Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
957647
952572
952572
952572
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TJ-9000 HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TJ-9000 1 stage, S.G. = 1
0
20
40
60
80
100
120
140
160
Ft
5
10
15
20
25
30
35
40
45
50
M
Head
0 5000 10000 15000 20000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
BPD
1000 2000 3000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 8.62 / 219 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
ENGINEERING DATA TM-19000A 60 HZ
273.1 MM
10-3/4 IN
2400 PSI
2400 PSI
2000 PSI
219.08MM
8-5/8 IN
849 HP
50 HZ 60 HZ
1-1/5 IN
30.48MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TM-19000A 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
25
50
75
100
125
150
Ft
10
20
30
40
M
Head
0 4000 8000 12000 16000 20000 24000 28000 32000 36000
0%
25%
50%
75%
100%
BPD
1000 2000 3000 4000 5000
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
10.0
20.0
30.0
40.0
50.0
60.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 8.62 / 219 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TM-19000A 50 HZ
Pump Performance Curve for TM-19000A 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
10-3/4 IN
273.1 MM
8-5/8 IN 1-1/5 IN
219.08MM 30.48MM
60 HZ 50 HZ
2400 PSI 1300 HP 1083 HP
2000 PSI 637 HP 531 HP
2400 PSI 1019 HP 849 HP
0
5
10
15
20
25
30
M
10
20
30
40
50
60
70
80
90
100
Ft
Head
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
0%
13%
25%
38%
50%
63%
75%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000 22500 25000 27500 30000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
20.0
25.0
30.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1
2 Exclude
3
4
5
6
7
8
9
10
11
12
13
14
15
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
TM-19000A HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-4
Variable Frequency Pump Performance Curve for TM-19000A 1 stage, S.G. = 1
0
50
100
150
200
250
Ft
10
20
30
40
50
60
70
80
90
M
Head
0 5000 10000 15000 20000 25000 30000 35000 40000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000 5000 6000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 8.62 / 219 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
ENGINEERING DATA TM-19000B 60 HZ
273.1 MM
10-3/4 IN
2400 PSI
2400 PSI
2000 PSI
219.08MM
8-5/8 IN
849 HP
50 HZ 60 HZ
1-1/5 IN
30.48MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TM-19000B 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
25
50
75
100
125
Ft
10
20
30
40
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 28000 30000
0%
25%
50%
75%
100%
BPD
500 1000 1500 2000 2500 3000 3500 4000 4500
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
10.0
20.0
30.0
40.0
50.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 8.62 / 219 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TM-19000B 50 HZ
Pump Performance Curve for TM-19000B 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
10-3/4 IN
273.1 MM
8-5/8 IN 1-1/5 IN
219.08MM 30.48MM
60 HZ 50 HZ
2400 PSI 1300 HP 1083 HP
2000 PSI 637 HP 531 HP
2400 PSI 1019 HP 849 HP
0
5
10
15
20
25
M
10
20
30
40
50
60
70
80
90
Ft
Head
0 500 1000 1500 2000 2500 3000 3500 4000
0%
25%
50%
75%
100%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000 22500 25000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
20.0
25.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1
2 Exclude
3
4
5
6
7
8
9
10
11
12
13
14
15
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
TM-19000B HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-6
Variable Frequency Pump Performance Curve for TM-19000B 1 stage, S.G. = 1
0
50
100
150
200
Ft
10
20
30
40
50
60
70
M
Head
0 5000 10000 15000 20000 25000 30000 35000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000 5000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 8.62 / 219 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5
ENGINEERING DATA TM-19000C 60 HZ
273.1 MM
10-3/4 IN
2400 PSI
2400 PSI
2000 PSI
219.08MM
8-5/8 IN
849 HP
50 HZ 60 HZ
1-1/5 IN
30.48MM
637 HP
1019 HP
1300 HP 1083 HP
Pump Performance Curve for TM-19000C 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
531 HP
0
25
50
75
100
Ft
10
20
30
M
Head
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000
0%
25%
50%
75%
100%
BPD
500 1000 1500 2000 2500 3000 3500 4000
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
10.0
20.0
30.0
40.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Pump O.D.* 8.62 / 219 mm
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009
ENGINEERING DATA TM-19000C 50 HZ
Pump Performance Curve for TM-19000C 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
10-3/4 IN
273.1 MM
8-5/8 IN 1-1/5 IN
219.08MM 30.48MM
60 HZ 50 HZ
2400 PSI 1300 HP 1083 HP
2000 PSI 637 HP 531 HP
2400 PSI 1019 HP 849 HP
0
5
10
15
20
M
10
20
30
40
50
60
70
Ft
Head
0 500 1000 1500 2000 2500 3000 3500
0%
25%
50%
75%
100%
M3/DAY
2500 5000 7500 10000 12500 15000 17500 20000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
5.0
10.0
15.0
20.0
HP
MTR
LOAD
Qmin BEP Qmax
Head
Efficiency
Power
CAPACITY
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1
2 Exclude
3
4
5
6
7
8
9
10
11
12
13
14
15
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.8 0.24 23 10.4
Coupling for Intake or GS 0.23 0.07 1.22 0.6
Pump to Pump Coupling - FLT
0.2 0.06
1.22
0.6
Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7
TM-19000C HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-8
Variable Frequency Pump Performance Curve for TM-19000C 1 stage, S.G. = 1
0
50
100
150
200
Ft
10
20
30
40
50
60
M
Head
0 5000 10000 15000 20000 25000 30000 35000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000 5000
M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Wood Group ESP, Inc.
#VALUE!
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1
833 HP
Pump Performance Curve for TN-35000A 1 stage @ 3500 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
50 HZ 60 HZ
1-1/2 IN
38.09MM
1000 HP
1600 HP
2040 HP 1700 HP
ENGINEERING DATA TN-35000A 60 HZ
298.5 MM
11-3/4 IN
2760 PSI
2760 PSI
2300 PSI
241.29MM
9-1/2 IN
1333 HP
0
25
50
75
100
125
150
175
200
225
Ft
10
20
30
40
50
60
70
M
Head
0 5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000 60000 65000 70000 75000
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
Head
Power
BPD
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
M3/DAY
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
25.0
50.0
75.0
100.0
125.0
150.0
175.0
200.0
225.0
HP
MTR
LOAD
Qmin BEP Qmax
Efficiency
CAPACITY
Pages Page 1
Wood Group ESP, Inc.
#VALUE!
MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW
HOUSING DIAMETER* SHAFT DIAMETER
HOUSING PRESSURE LIMIT SHAFT POWER LIMIT
STANDARD STANDARD
HIGH PRESSURE HIGH STRENGTH
ULTRA HIGH PRESSURE ULTRA HIGH STRENGTH
*Diameter does not include lockplates
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009
50 HZ
2760 PSI 2040 HP 1700 HP
2300 PSI 1000 HP 833 HP
2760 PSI 1600 HP 1333 HP
1-1/2 IN
241.29MM 38.09MM
60 HZ
11-3/4 IN
298.5 MM
9-1/2 IN
Pump Performance Curve for TN-35000A 1 stage @ 2917 RPM, S.G. = 1
These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API
representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)
ENGINEERING DATA TN-35000A 50 HZ
0
5
10
15
20
25
30
35
40
45
M
10
20
30
40
50
60
70
80
90
100
Ft
Head
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
0%
13%
25%
38%
50%
63%
75%
88%
100%
Head
Efficiency
Power
M3/DAY
5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000
BPD
RECOMMENDED
OPERATING RANGE
PMP
ONLY
EFF
0.0
12.5
25.0
37.5
50.0
62.5
75.0
87.5
100.0
112.5
HP
MTR
LOAD
Qmin BEP Qmax
CAPACITY
Pages Page 2
Wood Group ESP, Inc.
Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.
1 2.1 0.64 44 20.0 14 192421 13 192381 13 192391 12 192411
2 3.5 1.07 74 33.6 30 192422 29 192382 29 192392 27 192412
3 4.9 1.49 105 47.6 47 192423 45 192383 43 192393 41 192413
4 6.3 1.92 135 61.2 63 192424 62 192384 58 192394 56 192414
5 7.8 2.38 166 75.3 79 192425 78 192385 73 192395 71 192415
6 9.2 2.80 196 88.9 95 192426 94 192386 87 192396 87 192416
7 10.6 3.23 226 102.5 111 192427 102 192397
8 12 3.66 257 116.6 128 192428 117 192398
9 13.4 4.08 287 130.2 144 192429 131 192399
10 14.8 4.51 318 144.2 160 192430 146 192400
11 16.2 4.94 348 157.8 176 192431 161 192401
12 17.6 5.36 378 171.5 192 192432 175 192402
Feet Meters Lbs. Kgs.
Bolt on Head (2 3/8"-8rd) 0.3 0.09 10 4.5
Coupling for Intake or GS 0.21 0.06 0.77 0.3
Pump to Pump Coupling - FLT
0.2 0.06
0.5
0.2
Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3
Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of
shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your
Wood Group ESP representative.
930941
120556
934182
934232
Hsg
Length Weight
STANDARD PUMP ABRASION RESISTANT PUMP
Floater Compression
TN-35000A HOUSING DATA
Weight AR PUMP
Part No.
STANDARD PUMP
Part No.
Floater Compression
Length
Pages Page 3
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009
Variable Frequency Pump Performance Curve for TN-35000A 1 stage, S.G. = 1
0
50
100
150
200
250
300
350
400
Ft
10
20
30
40
50
60
70
80
90
100
M
Head
0 10000 20000 30000 40000 50000 60000 70000
45 Hz
50 Hz
55 Hz
60 Hz
65 Hz
70 Hz
75 Hz
80 Hz
85 Hz
BPD
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
11000 M3/DAY
RECOMMENDED
OPERATING RANGE
CAPACITY
Pages Page 4




Wood Group ESP, Inc.
























ENGINEERING DATA TM19000A 60 HZ
HOUSING DIAMETER 8.62 IN.

MINIMUM CASING SIZE 10-3/4 IN.

SHAFT DIAMETER 1-3/16 IN.
MINIMUM SHAFT AREA 1.1075 IN.

SHAFT LIMIT
STANDARD 637 HP
HIGH STRENGTH 1019 HP

HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 33 STAGES
HIGH STRENGTH 52 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 54 STAGES
HOUSING STANDARD 31 STAGES
HIGH PRESSURE 38 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1




Wood Group ESP, Inc.
























ENGINEERING DATA TM19000A 50 HZ
HOUSING DIAMETER 218.95 MM

MINIMUM CASING SIZE 273.05 MM

SHAFT DIAMETER 30.175 MM

MINIMUM SHAFT AREA 715.14 MMP
2

SHAFT LIMIT
STANDARD 531 HP
HIGH STRENGTH 849 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 47 STAGES
HIGH STRENGTH 75 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 70 STAGES
HOUSING STANDARD 45 STAGES
HIGH PRESSURE 54 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** - For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TM19000B 60 HZ
HOUSING DIAMETER 8.62 IN.

MINIMUM CASING SIZE 10-3/4 IN.

SHAFT DIAMETER 1-3/16 IN.

MINIMUM SHAFT AREA 1.1075 IN.

SHAFT LIMIT
STANDARD 637 HP
HIGH STRENGTH 1019 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 44 STAGES
HIGH STRENGTH 71 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 64 STAGES
HOUSING STANDARD 38 STAGES
HIGH PRESSURE 45 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX)18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3




Wood Group ESP, Inc.
























ENGINEERING DATA TM19000B 50 HZ
HOUSING DIAMETER 218.95 MM

MINIMUM CASING SIZE 273.05 MM

SHAFT DIAMETER 30.175 MM

MINIMUM SHAFT AREA 715.14 MMP
2

SHAFT LIMIT
STANDARD 531 HP
HIGH STRENGTH 849 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 64 STAGES
HIGH STRENGTH 102 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 84 STAGES
HOUSING STANDARD 54 STAGES
HIGH PRESSURE 65 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
























ENGINEERING DATA TM19000C 50 HZ
HOUSING DIAMETER 218.95 MM

MINIMUM CASING SIZE 273.05 MM

SHAFT DIAMETER 30.175 MM

MINIMUM SHAFT AREA 715.14 MMP
2

SHAFT LIMIT
STANDARD 531 HP
HIGH STRENGTH 849 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 73 STAGES
HIGH STRENGTH 117 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 103 STAGES
HOUSING STANDARD 67 STAGES
HIGH PRESSURE 80 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
TM-19000 PUMP
862 Series - Compression
Length Weight No. A-Cut B-Cut C-Cut
Hsg
Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number
3 3.3 1.01 528 239.4 3 117653 117311 117683
4 3.9 1.19 587 266.2 4 117654 117312 117684
5 4.5 1.37 662 300.2 5 117655 117313 117685
6 5.1 1.55 729 330.6 6 117656 117314 117686
7 5.7 1.74 789 357.8 7 117657 117315 117687
8 6.3 1.92 863 391.4 8 117658 117316 117688
9 6.9 2.10 931 422.2 9 117659 117317 117689
10 7.5 2.29 991 449.4 10 117660 117318 117690
11 8.1 2.47 1058 479.8 11 117661 117319 117691
12 8.7 2.65 1126 510.6 12 117662 117320 117692
13 9.3 2.83 1193 541.0 13 117663 117321 117693
14 9.9 3.02 1260 571.4 14 117664 117322 117694
15 10.6 3.23 1327 601.8 15 117665 117323 117695
16 11.2 3.41 1395 632.6 16 117666 117371 117696
17 11.8 3.60 1466 664.8 17 117667 117372 117697
18 12.4 3.78 1533 695.2 18 117668 117373 117698
19 13.0 3.96 1596 723.8 19 117669 117374 117699
20 13.6 4.15 1664 754.6 20 117670 117200 117700
21 14.2 4.33 1734 786.4 21 117671 117375 117701
22 14.8 4.51 1801 816.8 22 117672 117376 117702
23 15.4 4.69 1866 846.2 23 117673 117377 117703
24 16.0 4.88 1933 876.6 24 117674 117378 117704
25 16.6 5.06 2003 908.4 25 117675 117379 117705
26 17.2 5.24 2071 939.2 26 117676 117380 117706
27 17.8 5.43 2138 969.6 27 117677 117381 117707
28 18.4 5.61 2202 998.6 28 117678 117382 117708
29 19.0 5.79 2272 1030.4 29 117679 117383 117709
30 19.6 5.97 2339 1060.7 30 117680 117384 117710
31 20.2 6.16 2407 1091.6 31 117681 117385 117711
32 20.8 6.34 2474 1122.0 32 117682 117386 117712


Length Weight STANDARD PUMP
Feet Meters Lbs. Kgs. Part No.
Bolt on Head (7-8rd)-LT 0.97 0.30 62 28.1 117786
Coupling for Intake or GS 0.22 0.06 1.22 0.55 952572
Pump to Pump Coupling 0.22 0.06 1.22 0.55 952572
Shim Kit 0.08 0.02 0.06 0.03 131613
Pumps are center tandem configuration that can be stacked to achieve desired number of stages
up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel
housings. For design requirements not listed consult your Wood Group ESP representative.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TM24000A 60 HZ
HOUSING DIAMETER 8.62 IN.

MINIMUM CASING SIZE 10-3/4 IN.

SHAFT DIAMETER 1-3/16 IN.

MINIMUM SHAFT AREA 1.1075 IN.

SHAFT LIMIT
STANDARD 637 HP
HIGH STRENGTH 1019 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 20 STAGES
HIGH STRENGTH 32 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 55 STAGES
HOUSING STANDARD 29 STAGES
HIGH PRESSURE 35 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11




Wood Group ESP, Inc.
























ENGINEERING DATA TM24000A 50 HZ
HOUSING DIAMETER 218.95 MM

MINIMUM CASING SIZE 273.05 MM

SHAFT DIAMETER 30.175 MM

MINIMUM SHAFT AREA 715.14 MMP
2

SHAFT LIMIT
STANDARD 531 HP
HIGH STRENGTH 849 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 29 STAGES
HIGH STRENGTH 46 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 71 STAGES
HOUSING STANDARD 42 STAGES
HIGH PRESSURE 51 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TM24000B 60 HZ
HOUSING DIAMETER 8.62 IN.

MINIMUM CASING SIZE 10-3/4 IN.

SHAFT DIAMETER 1-3/16 IN.

MINIMUM SHAFT AREA 1.1075 IN.

SHAFT LIMIT
STANDARD 637 HP
HIGH STRENGTH 1019 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 23 STAGES
HIGH STRENGTH 36 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 65 STAGES
HOUSING STANDARD 37 STAGES
HIGH PRESSURE 44 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13




Wood Group ESP, Inc.
























ENGINEERING DATA TM24000B 50 HZ
HOUSING DIAMETER 218.95 MM

MINIMUM CASING SIZE 273.05 MM

SHAFT DIAMETER 30.175 MM

MINIMUM SHAFT AREA 715.14 MMP
2

SHAFT LIMIT
STANDARD 531 HP
HIGH STRENGTH 849 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 32 STAGES
HIGH STRENGTH 52 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 84 STAGES
HOUSING STANDARD 53 STAGES
HIGH PRESSURE 64 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TM24000C 60 HZ
HOUSING DIAMETER 8.62 IN.

MINIMUM CASING SIZE 10-3/4 IN.

SHAFT DIAMETER 1-3/16 IN.

MINIMUM SHAFT AREA 1.1075 IN.

SHAFT LIMIT
STANDARD 637 HP
HIGH STRENGTH 1019 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 31 STAGES
HIGH STRENGTH 49 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 81 STAGES
HOUSING STANDARD 46 STAGES
HIGH PRESSURE 55 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15




Wood Group ESP, Inc.
























ENGINEERING DATA TM24000C 50 HZ
HOUSING DIAMETER 218.95 MM

MINIMUM CASING SIZE 273.05 MM

SHAFT DIAMETER 30.175 MM
MINIMUM SHAFT AREA 715.14 MMP
2

SHAFT LIMIT
STANDARD 531 HP
HIGH STRENGTH 849 HP
HOUSING PRESSURE LIMIT
STANDARD 2000 PSI
HIGH PRESSURE 2400 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 45 STAGES
HIGH STRENGTH 71 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 105 STAGES
HOUSING STANDARD 67 STAGES
HIGH PRESSURE 80 STAGES


THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** - For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-16 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
TM-24000 PUMP
862 Series - Compression
Length Weight No. A-Cut B-Cut C-Cut
Hsg
Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number
3 3.3 1.01 528 239.4 3 117473 117503 117533
4 3.9 1.19 587 266.2 4 117474 117504 117534
5 4.5 1.37 662 300.2 5 117475 117505 117535
6 5.1 1.55 729 330.6 6 117476 117506 117536
7 5.7 1.74 789 357.8 7 117477 117507 117537
8 6.3 1.92 863 391.4 8 117478 117508 117538
9 6.9 2.10 931 422.2 9 117479 117509 117539
10 7.5 2.29 991 449.4 10 117480 117510 117540
11 8.1 2.47 1058 479.8 11 117481 117511 117541
12 8.7 2.65 1126 510.6 12 117482 117512 117542
13 9.3 2.83 1193 541.0 13 117483 117513 117543
14 9.9 3.02 1260 571.4 14 117484 117514 117544
15 10.6 3.23 1327 601.8 15 117485 117515 117545
16 11.2 3.41 1395 632.6 16 117486 117516 117546
17 11.8 3.60 1466 664.8 17 117487 117517 117547
18 12.4 3.78 1533 695.2 18 117488 117518 117548
19 13.0 3.96 1596 723.8 19 117427 117519 117549
20 13.6 4.15 1664 754.6 20 117428 117520 117550
21 14.2 4.33 1734 786.4 21 117491 117521 117551
22 14.8 4.51 1801 816.8 22 117492 117522 117552
23 15.4 4.69 1866 846.2 23 117493 117523 117553
24 16.0 4.88 1933 876.6 24 117494 117524 117554
25 16.6 5.06 2003 908.4 25 117495 117525 117555
26 17.2 5.24 2071 939.2 26 117496 117526 117556
27 17.8 5.43 2138 969.6 27 117497 117527 117557
28 18.4 5.61 2202 998.6 28 117498 117528 117558
29 19.0 5.79 2272 1030.4 29 117499 117529 117559
30 19.6 5.97 2339 1060.7 30 117500 117530 117560
31 20.2 6.16 2407 1091.6 31 117501 117531 117561
32 20.8 6.34 2474 1122.0 32 117502 117532 117562

Length Weight STANDARD PUMP
Feet Meters Lbs. Kgs. Part No.
Bolt on Head (7-8rd) 0.97 0.30 62 28.1 117786
Coupling for Intake or GS 0.22 0.06 1.22 0.55 952572
Pump to Pump Coupling 0.22 0.06 1.22 0.55 952572
Shim Kit 0.08 0.02 0.06 0.03 131613
Pumps are center tandem configuration that can be stacked to achieve desired number of stages
up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel
housings. For design requirements not listed consult your Wood Group ESP representative.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-18 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-20 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
























ENGINEERING DATA TN35000A 60 HZ
HOUSING DIAMETER 9.50 IN.

MINIMUM CASING SIZE 11-3/4 IN.
SHAFT DIAMETER 1-1/2 IN.

MINIMUM SHAFT AREA 1.7671 IN.

SHAFT LIMIT
STANDARD 1000 HP
HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 17 STAGES
HIGH STRENGTH 27 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 19 STAGES
HOUSING STANDARD 25 STAGES
HIGH PRESSURE 30 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000A 50 HZ
HOUSING DIAMETER 241.30 MM

MINIMUM CASING SIZE 298.45 MM
SHAFT DIAMETER 38.1 MM

MINIMUM SHAFT AREA 1140.09 MM
2

SHAFT LIMIT
STANDARD 833 HP
HIGH STRENGTH 1333 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 24 STAGES
HIGH STRENGTH 39 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 25 STAGES
HOUSING STANDARD 36 STAGES
HIGH PRESSURE 43 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX)16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000B 60 HZ
HOUSING DIAMETER 9.50 IN.

MINIMUM CASING SIZE 11-3/4 IN.
SHAFT DIAMETER 1-1/2 IN.

MINIMUM SHAFT AREA 1.7671 IN.

SHAFT LIMIT
STANDARD 1000 HP
HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 23 STAGES
HIGH STRENGTH 36 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 23 STAGES
HOUSING STANDARD 30 STAGES
HIGH PRESSURE 36 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000B 50 HZ
HOUSING DIAMETER 241.30 MM

MINIMUM CASING SIZE 298.45 MM
SHAFT DIAMETER 38.1 MM

MINIMUM SHAFT AREA 1140.09 MM
2

SHAFT LIMIT
STANDARD 833 HP
HIGH STRENGTH 1333 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 33 STAGES
HIGH STRENGTH 52 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 30 STAGES
HOUSING STANDARD 43 STAGES
HIGH PRESSURE 51 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000C 60 HZ
HOUSING DIAMETER 9.50 IN.

MINIMUM CASING SIZE 11-3/4 IN.
SHAFT DIAMETER 1-1/2 IN.

MINIMUM SHAFT AREA 1.7671 IN.

SHAFT LIMIT
STANDARD 1000 HP
HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 29 STAGES
HIGH STRENGTH 47 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 28 STAGES
HOUSING STANDARD 35 STAGES
HIGH PRESSURE 43 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000C 50 HZ
HOUSING DIAMETER 241.30 MM

MINIMUM CASING SIZE 298.45 MM
SHAFT DIAMETER 38.1 MM

MINIMUM SHAFT AREA 1140.09 MM
2

SHAFT LIMIT
STANDARD 833 HP
HIGH STRENGTH 1333 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 42 STAGES
HIGH STRENGTH 67 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 36 STAGES
HOUSING STANDARD 51 STAGES
HIGH PRESSURE 61 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
TN-35000 UT PUMP
950 Series - Compression
Length Weight No. A-Cut B-Cut C-Cut
Hsg
Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number
1 2.4 0.73 516 234.0 1 1033018 1033216 1033414
2 3.0 0.91 592 268.5 2 1033026 1033224 1033422
3 3.6 1.10 668 302.9 3 1033034 1033232 1033430
4 4.2 1.28 744 337.4 4 1033042 1033240 1033448
5 4.7 1.43 817 370.5 5 1033059 1033257 1033455
6 5.3 1.62 892 404.5 6 1033067 1033265 1033463
7 5.9 1.80 968 439.0 7 1033075 1033273 1033471
8 6.5 1.98 1044 473.5 8 1033083 1033281 1033489
9 7.1 2.16 1120 507.9 9 1033091 1033299 1033497
10 7.6 2.32 1193 541.0 10 1033109 1033307 1033505
11 8.2 2.50 1269 575.5 11 1033117 1033315 1033513
12 8.8 2.68 1345 610.0 12 1033125 1033323 1033521
13 9.4 2.87 1421 644.4 13 1033133 1033331 1033539
14 10.0 3.05 1497 678.9 14 1033141 1033349 1033547
15 10.6 3.23 1573 713.4 15 1033158 1033356 1033554
16 11.1 3.38 1649 747.6 16 1033364 1033562
17 11.7 3.57 1725 762.3 17 1033372 1033570
18 12.3 3.75 1801 816.8 18 1033380 1033588
19 12.9 3.93 1877 851.2 19 1033398 1033596
20 13.5 4.11 1953 885.7 20 1033406 1033604











Length Weight STANDARD PUMP
Feet Meters Lbs. Kgs. Part No.
Coupling for Intake or GS 0.22 0.06 1.22 0.55 1032770
Pump to Pump Coupling 0.22 0.06 1.22 0.55 1032770
Shim Kit 0.08 0.02 0.02 0.01 131613
Pumps are upper tandem configuration. Part numbers shown are for pumps constructed with steel
housings. For design requirements not listed consult your Wood Group ESP representative.


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000A 60 HZ
HOUSING DIAMETER 9.50 IN.

MINIMUM CASING SIZE 11-3/4 IN.
SHAFT DIAMETER 1-1/2 IN.

MINIMUM SHAFT AREA 1.7671 IN.

SHAFT LIMIT
STANDARD 1000 HP
HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 17 STAGES
HIGH STRENGTH 27 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 19 STAGES
HOUSING STANDARD 25 STAGES
HIGH PRESSURE 30 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000A 50 HZ
HOUSING DIAMETER 241.30 MM

MINIMUM CASING SIZE 298.45 MM
SHAFT DIAMETER 38.1 MM

MINIMUM SHAFT AREA 1140.09 MM
2

SHAFT LIMIT
STANDARD 833 HP
HIGH STRENGTH 1333 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 24 STAGES
HIGH STRENGTH 39 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 25 STAGES
HOUSING STANDARD 36 STAGES
HIGH PRESSURE 43 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX)16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000B 60 HZ
HOUSING DIAMETER 9.50 IN.

MINIMUM CASING SIZE 11-3/4 IN.
SHAFT DIAMETER 1-1/2 IN.

MINIMUM SHAFT AREA 1.7671 IN.

SHAFT LIMIT
STANDARD 1000 HP
HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 23 STAGES
HIGH STRENGTH 36 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 23 STAGES
HOUSING STANDARD 30 STAGES
HIGH PRESSURE 36 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000B 50 HZ
HOUSING DIAMETER 241.30 MM

MINIMUM CASING SIZE 298.45 MM
SHAFT DIAMETER 38.1 MM

MINIMUM SHAFT AREA 1140.09 MM
2

SHAFT LIMIT
STANDARD 833 HP
HIGH STRENGTH 1333 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 33 STAGES
HIGH STRENGTH 52 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 30 STAGES
HOUSING STANDARD 43 STAGES
HIGH PRESSURE 51 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000C 60 HZ
HOUSING DIAMETER 9.50 IN.

MINIMUM CASING SIZE 11-3/4 IN.
SHAFT DIAMETER 1-1/2 IN.

MINIMUM SHAFT AREA 1.7671 IN.

SHAFT LIMIT
STANDARD 1000 HP
HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING *
SHAFT STANDARD 29 STAGES
HIGH STRENGTH 47 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 28 STAGES
HOUSING STANDARD 35 STAGES
HIGH PRESSURE 43 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 18000 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5




Wood Group ESP, Inc.
























ENGINEERING DATA TN35000C 50 HZ
HOUSING DIAMETER 241.30 MM

MINIMUM CASING SIZE 298.45 MM
SHAFT DIAMETER 38.1 MM

MINIMUM SHAFT AREA 1140.09 MM
2

SHAFT LIMIT
STANDARD 833 HP
HIGH STRENGTH 1333 HP

HOUSING PRESSURE LIMIT
STANDARD 2300 PSI
HIGH PRESSURE 2760 PSI
ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:*
SHAFT STANDARD 42 STAGES
HIGH STRENGTH 67 STAGES
THRUST BEARING - COMPRESSION PUMP
HIGH LOAD (250F BHT MAX)** 36 STAGES
HOUSING STANDARD 51 STAGES
HIGH PRESSURE 61 STAGES



THRUST BEARING CAPACITY
HIGH LOAD (250F BHT MAX) 16300 LBS.
* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or
contact your local Wood Group ESP representative.
** For applications above 250F, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
TN-35000 UT PUMP
950 Series - Compression
Length Weight No. A-Cut B-Cut C-Cut
Hsg
Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number
1 2.4 0.73 516 234.0 1 1033018 1033216 1033414
2 3.0 0.91 592 268.5 2 1033026 1033224 1033422
3 3.6 1.10 668 302.9 3 1033034 1033232 1033430
4 4.2 1.28 744 337.4 4 1033042 1033240 1033448
5 4.7 1.43 817 370.5 5 1033059 1033257 1033455
6 5.3 1.62 892 404.5 6 1033067 1033265 1033463
7 5.9 1.80 968 439.0 7 1033075 1033273 1033471
8 6.5 1.98 1044 473.5 8 1033083 1033281 1033489
9 7.1 2.16 1120 507.9 9 1033091 1033299 1033497
10 7.6 2.32 1193 541.0 10 1033109 1033307 1033505
11 8.2 2.50 1269 575.5 11 1033117 1033315 1033513
12 8.8 2.68 1345 610.0 12 1033125 1033323 1033521
13 9.4 2.87 1421 644.4 13 1033133 1033331 1033539
14 10.0 3.05 1497 678.9 14 1033141 1033349 1033547
15 10.6 3.23 1573 713.4 15 1033158 1033356 1033554
16 11.1 3.38 1649 747.6 16 1033364 1033562
17 11.7 3.57 1725 762.3 17 1033372 1033570
18 12.3 3.75 1801 816.8 18 1033380 1033588
19 12.9 3.93 1877 851.2 19 1033398 1033596
20 13.5 4.11 1953 885.7 20 1033406 1033604











Length Weight STANDARD PUMP
Feet Meters Lbs. Kgs. Part No.
Coupling for Intake or GS 0.22 0.06 1.22 0.55 1032770
Pump to Pump Coupling 0.22 0.06 1.22 0.55 1032770
Shim Kit 0.08 0.02 0.02 0.01 131613
Pumps are upper tandem configuration. Part numbers shown are for pumps constructed with steel
housings. For design requirements not listed consult your Wood Group ESP representative.


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9




Wood Group ESP, Inc.























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009



Wood Group ESP, Inc.

BOLT ON INTAKES
DESCRIPTION
PUMP SERIES 338
INTAKE, PUMP BO TA STL
INTAKE, PUMP BO TA SST
INTAKE, PUMP BO TA AR STL
INTAKE, PUMP BO TA AR SST
INTAKE, PUMP BO TA AR STL HSS
PUMP SERIES 387
INTAKE, PUMP BO TR387 STL
INTAKE, PUMP BO TR387 SST
INTAKE, PUMP BO TR387 AR STL
INTAKE, PUMP BO TR387 AR SST
PUMP SERIES 400
INTAKE, PUMP BO TD STL
INTAKE, PUMP BO TD SST
INTAKE, PUMP BO TD AR STL
INTAKE, PUMP BO TD AR SST
INTAKE, PUMP BO TD AR STL HSS
INTAKE, PUMP BO TD AR SST HSS
INTAKE, PUMP BO TD AR NITRIDE
INTAKE, PUMP BO TD AR FPS
INTAKE, PUMP BO TD AR DURAGUARD
INTAKE, PUMP BO TD AR BDP STL
INTAKE, PUMP BO TD AR 316SST HSS
INTAKE, PUMP BO TD AR STL UHSS
INTAKE, PUMP BO TD AR 316SST UHSS
PUMP SERIES 513 / 538
INTAKE, PUMP BO TE/TG STL
INTAKE, PUMP BO TE/TG STL HSS
INTAKE, PUMP BO TE/TG SST
INTAKE, PUMP BO TE/TG AR STL
INTAKE, PUMP BO TE/TG AR SST
PUMP SERIES 562
INTAKE, PUMP BO TH STL
INTAKE, PUMP BO TH SST
INTAKE, PUMP BO TH AR STL HSS
INTAKE, PUMP BO TH AR STL
INTAKE, PUMP BO TH AR SST HSS
INTAKE, PUMP BO TH AR SST
HP Rating Length
60Hz 50Hz Ft. M.
125 104 0.77 0.23
125 104 0.77 0.23
125 104 0.77 0.23
125 104 0.77 0.23
200 167 0.77 0.23
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
410 342 1 0.3
410 342 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
256 213 1 0.3
410 342 1 0.3
522 435 1 0.3
522 435 1 0.3
637 531 1.24 0.38
1019 849 1.24 0.38
637 531 1.24 0.38
1019 849 1.24 0.38
1019 849 1.24 0.38
637 531 1.24 0.38
637 531 1.24 0.38
1019 849 1.24 0.38
637 531 1.24 0.38
1019 849 1.24 0.38
637 531 1.24 0.38
Weight PART
Lbs. Kgs. NO.
18 8.16 1021443
18 8.16 113143
18 8.16 113429
18 8.16 113430
18 8.16 113722
28 12.7 116080
28 12.7 116081
28 12.7 150732
28 12.7 150733
28 12.7 935858
28 12.7 1006071
28 12.7 140796
28 12.7 140800
28 12.7 140801
28 12.7 140802
28 12.7 150212
28 12.7 150593
28 12.7 150640
28 12.7 170427
28 12.7 170814
28 12.7 190063
28 12.7 190149
45 20.41 138028
45 20.41 141221
45 20.41 138029
45 20.41 138032
45 20.41 138033
50 22.68 123206
50 22.68 123410
50 22.68 136098
50 22.68 123585
50 22.68 153245
50 22.68 173022



Wood Group ESP, Inc.
The ESP Specialists www.woodgroup-esp.com
Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009 Page - 1


Wood Group ESP, Inc.


BOLT ON INTAKES
DESCRIPTION
PUMP SERIES 675
INTAKE, PUMP BO TJ STL
INTAKE, PUMP BO TJ SST
INTAKE, PUMP BO TJ STL HSS
INTAKE, PUMP BO TJ AR STL
INTAKE, PUMP BO TJ AR SST
INTAKE, PUMP BO TJ AR SST HSS
INTAKE, PUMP BO TJ AR SST UHSS
PUMP SERIES 862
INTAKE, PUMP BO TM STL
INTAKE, PUMP BO TM SST
INTAKE, PUMP BO TM AR SHORT STL
PUMP SERIES 950
INTAKE, PUMP BO TN/TR7 SEAL STL
INTAKE, PUMP BO TN/TR7 SEAL SST
INTAKE, PUMP BO TN STL
INTAKE, PUMP BO TN SST
HP Rating Length
60Hz 50Hz Ft. M.

637 531 0.73 0.22
637 531 0.73 0.22
1019 849 0.73 0.22
637 531 0.73 0.22
637 531 0.73 0.22
1019 849 0.73 0.22
1281 1067 0.73 0.22

637 531 0.8 0.24
637 531 0.8 0.24
637 531 0.8 0.24

1000 833 0.83 0.25
1000 833 0.83 0.25
1000 833 0.83 0.25
1000 833 0.83 0.25
Weight
PART NO.
Lbs. Kgs.
56 25.4 957498
56 25.4 117409
56 25.4 147744
56 25.4 117791
56 25.4 117819
56 25.4 147070
56 25.4 157077
75 34 977710
75 34 117961
75 34 117787
85 38.6 1033612
85 38.6 147012
85 38.6 1032705
85 38.6 1033687



























Wood Group ESP, Inc.
The ESP Specialists www.woodgroup-esp.com
Page - 2 Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009



Wood Group ESP, Inc.


GAS SEPARATORS

Wood Group ESP offers a variety of gas separator models for different well conditions. These models
are offered in all three series. It is important to mention here the features of these models.

STANDARD (3B-3 Bearing Separators):
These separators are intended for use in abrasive / non-abrasive well conditions. Solid tungsten
carbide bushing/sleeves are used in these units. Internal compression tubes are coated with a highly
abrasive resistant coating. Units are provided with a stainless steel base.
STAINLESS STEEL (SST):
In a SST construction, SST is used to make the following components. All other components are the
same as the standard unit.
Head
Lock ring / Compression nut
Ferretic Housing (9 Chrome 1 Moly)
WAG UNITS:
WAG units are designed for highly corrosive CO2 environments. These units essentially have SST
construction with the following features added
SST Housing (410 SST)
Lock plates are not used on these units. Housing joints are locked with a thread
XGC MODELS:
XGC models are designed for applications having excessive gas. Any of the above mentioned models
can be offered in XGC separators.
XGVS MODELS:
The Extra Gas Volume Separator is available in 538 series for high volume applications up to 7,500
BPD liquid rate. XGVS units are constructed in corrosion resistant configuration as standard with three
tungsten carbide bearings, stainless steel head and base, stainless steel internal parts, T9 housing,
and MonelK-500 shaft. The high strength shaft (HSS) option upgrades the shaft to Inconel718.
MAGS MODELS:
The Multi-stage Abrasion-resistant Gas Separator (MAGS) of Wood Group ESP features patented
designs to achieve high gas separation efficiencies in a wide range of production flow rates. The 400
series MAGS has the maximum capacity of 8,000 BPD liquid production. And the 538 series MAGS can
handle liquid flow rate up to 16,000 BPD. As standard features, all MAGS units are equipped with
stainless steel head and base, Tungsten Carbide (TC) bushing and sleeve for radial bearings, TC
coated stainless steel compression tubes, and Ni-resist steel casting inducers, diffusers, and
crossovers. The MAGS is suitable for high temperature environment with key-locked TC bushings to
the bearing supports.
The 538 series gas separators (XGVS and MAGS) are Left Hand Threads.
COATINGS:
Any gas separator can be supplied with coated internals. Coatings available are the same as those
available for pump stages. Typical coatings are BDP (Boron Diffusion Process) for abrasives and FPS
(Fluoropolymer System) for scale.

Wood Group ESP, Inc.
The ESP Specialists www.woodgroup-esp.com
Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009 Page - 3



Wood Group ESP, Inc.


GAS SEPARATORS
DESCRIPTION
TR3 SERIES
GAS SEPERATOR TR3 RS
GAS SEPARATOR TR3 UT
GAS SEPARATOR TR3 LT STL HSS
Length Weight
Ft. M. Lbs. Kgs.

2.21 0.67 38 17.23
2.25 0.69 38 17.23
2.21 0.67 38 17.23
Part No.

113091
113275
113625

ENGINEERING DATA - TR3 SERIES
60 HZ OPERATION
50 HZ OPERATION

HOUSING DIAMETER 3-3/8 IN
HOUSING DIAMETER 85.85 MM
SHAFT DIAMETER 11/16 IN SHAFT DIAMETER 17.42 MM
SHAFT LIMIT STANDARD 125 HP SHAFT LIMIT STANDARD 104 HP
HIGH STRENGTH 200 HP
HIGH STRENGTH 167 HP

DESCRIPTION
TR387 SERIES
GAS SEPARATOR TR387 3B LT STL
GAS SEPARATOR TR387 3B LT SST

Length Weight
Ft. M. Lbs. Kgs.

3.02 0.92 68.00 30.84
3.02 0.92 68.00 30.84
Part No.
141925
113566

ENGINEERING DATA - TR387 SERIES
60 HZ OPERATION
50 HZ OPERATION
HOUSING DIAMETER 3.87 IN HOUSING DIAMETER 98.30 MM
SHAFT DIAMETER 7/8 IN
SHAFT DIAMETER 22.2 MM
SHAFT LIMIT STANDARD 256 HP
SHAFT LIMIT STANDARD 213 HP
HIGH STRENGTH 410 HP HIGH STRENGTH 342 HP


















Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 4 Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009


Wood Group ESP, Inc.


GAS SEPARATORS
DESCRIPTION
TR4 SERIES
GAS SEPARATOR TR4 3B LT STL
GAS SEPARATOR TR4 3B LT SST
GAS SEPARATOR TR4 3B LT HSS
GAS SEPARATOR TR4 3B LT BDP
GAS SEPARATOR TR4 3B LT FPS
GAS SEPARATOR TR4 3B LT SST HSS GAS
SEPARATOR TR4 3B LT SST WAG GAS
SEPARATOR TR4 3B LT SST UHSS WAG GAS
SEPARATOR TR4 3B LT SST SR
GAS SEPARATOR TR4 3B UT STL
GAS SEPARATOR TR4 3B UT SST
GAS SEPARATOR TR4 UT STL HSS
GAS SEPARATOR TR4 UT SST HSS
Length
Ft. M.

3.02 0.92
3.02 0.92
3.02 0.92
3.02 0.92
3.02 0.92
3.02 0.92
3.02 0.92
3.02 0.92
3.02 0.92
3.06 0.93
3.06 0.93
3.06 0.93
3.06 0.93
Weight
Lbs. Kgs.

72 32.65
72 32.65
72 32.65
72 32.65
72 32.65
72 32.65
71 32.2
71 32.2
73 33.11
70 31.75
70 31.75
70 31.75
70 31.75

PART
NO.
160118
150624
160122
160400
160126
160128
141464
150465
150425
160130
160132
160134
160136









GAS SEPARATOR TR4 AR MAGS-3 SST T9 HSS 6.23 1.90 143 65 192455
GAS SEPARATOR TR4 AR MAGS-3 SST HSS 6.23 1.90 143 65 192469
GAS SEPARATOR TR4 AR MAGS-3 SST T9 UHSS 6.23 1.90 143 65 192708

ENGINEERING DATA - TR4 SERIES
60 HZ OPERATION
HOUSING DIAMETER 4.00 IN
SHAFT DIAMETER 7/8 IN
SHAFT LIMIT STANDARD 256 HP
HIGH STRENGTH 410 HP
ULTRA HIGH STRENGTH 522 HP
50 HZ OPERATION
HOUSING DIAMETER 101.60 MM
SHAFT DIAMETER 22.2 MM
SHAFT LIMIT STANDARD 213 HP
HIGH STRENGTH 342 HP
ULTRA HIGH STRENGTH 435 HP








Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. October, 2009 Page - 5


Wood Group ESP, Inc.


GAS SEPARATORS
DESCRIPTION
TR5 SERIES
GAS SEPARATOR TR5 3B LT STL
GAS SEPARATOR TR5 3B LT SST
GAS SEPARATOR TR5 3B LT STL HSS
GAS SEPARATOR TR5 3B LT SST HSS
GAS SEPARATOR TR5 3B LT STL BDP
GAS SEPARATOR TR5 3B LT SST FPS
GAS SEPARATOR TR5 3B LT SST WAG
GAS SEPARATOR TR5 3B UT STL
GAS SEPARATOR TR5 3B UT SST
GAS SEPARATOR TR5 3B UT STL HSS
GAS SEPARATOR TR5 3B UT SST HSS

Length Weight
Ft. M. Lbs. Kgs.

3.2 0.98 132 59.86
3.2 0.98 132 59.86
3.2 0.98 132 59.86
3.2 0.98 132 59.86
3.2 0.98 132 59.86
3.2 0.98 132 59.86
3.2 0.98 131 59.41
3.2 0.98 140 63.49
3.2 0.98 140 63.49
3.2 0.98 140 63.49
3.2 0.98 140 63.49
PART NO.

141463
141254
151089
151458
151345
151092
151104
151106
151108
151110
151112









ENGINEERING DATA - TR5
60 HZ OPERATION
HOUSING DIAMETER 5-1/8 IN
SHAFT DIAMETER 1-3/16 IN
SHAFT LIMIT STANDARD 637 HP
HIGH STRENGTH 1019 HP
50 HZ OPERATION
HOUSING DIAMETER 130.30 MM
SHAFT DIAMETER 30.20 MM
SHAFT LIMIT STANDARD 531 HP
HIGH STRENGTH 849 HP















Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 6 Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. October, 2009



Wood Group ESP, Inc.


GAS SEPARATORS
DESCRIPTION
TR538 SERIES
GAS SEPARATOR TR538 XGVS LT SST T9
GAS SEPARATOR TR538 XGVS LT SST T9 HSS
GAS SEPARATOR TR538 XGVS UT SST T9
GAS SEPARATOR TR538 XGVS UT SST T9 HSS
Length Weight
Ft. M. Lbs. Kgs.

3.59 1.09 140 63.49
3.59 1.09 140 63.49
3.25 0.99 135 61.22
3.25 0.99 135 61.22
PART NO.
158136
158102
158139
158122

GAS SEPARATOR TR538 AR MAGS-3 SST T9 HSS
7.70 2.35 256 116 161308
GAS SEPARATOR TR538 AR MAGS-3 SST HSS 7.70 2.35 256 116 161309
GAS SEPARATOR TR538 AR MAGS-3 SST
7.70 2.35 256 116 161325

ENGINEERING DATA - TR538
60 HZ OPERATION
HOUSING DIAMETER 5-3/8 IN
SHAFT DIAMETER 1-3/16 IN
SHAFT LIMIT STANDARD 637 HP
HIGH STRENGTH 1019 HP
50 HZ OPERATION
HOUSING DIAMETER 136.50 MM
SHAFT DIAMETER 30.20 MM
SHAFT LIMIT STANDARD 531 HP
HIGH STRENGTH 849 HP

TR675 SERIES
Lower Tandem / Single for attachment to TR5 Seal
GAS SEPARATOR TR675-TR5 LT 3.48 1.06 190 86.17
118213
GAS SEPARATOR TR675-TR5 LT SST 3.48 1.06 190 86.17
118167
GAS SEPARATOR TR675-TR5 LT HSS 3.48 1.06 190 86.17 118215
GAS SEPARATOR TR675-TR5 LT SST HSS 3.48 1.06 190 86.17
118217
lower Tandem / Single for attachment to TR7 Seal
GAS SEPARATOR TR675 LT
3.48 1.06 190
86.17 118195
GAS SEPARATOR TR675 LT SST
3.48 1.06 190
86.17 118211
GAS SEPARATOR TR675 LT HSS 3.48 1.06 190 86.17 118197
GAS SEPARATOR TR675 LT SST HSS 3.48 1.06 190 86.17
118199
Upper Tandem
GAS SEPARATOR TR675 UT 3.48 1.06 190 86.17 118201
GAS SEPARATOR TR675 UT SST
3.48 1.06 190
86.17 118203
GAS SEPARATOR TR675 UT HSS 3.48 1.06 190 86.17
118205
GAS SEPARATOR TR675 UT SST HSS 3.48 1.06 190 86.17 118207

ENGINEERING DATA - TR675
60 HZ OPERATION 50 HZ OPERATION
HOUSING DIAMETER 6.750 IN HOUSING DIAMETER 171.45 MM
SHAFT DIAMETER 1.187 IN SHAFT DIAMETER 30.20 MM
SHAFT LIMIT STANDARD 637 HP SHAFT LIMIT STANDARD 531 HP
HIGH STRENGTH 1019 HP HIGH STRENGTH 849 HP

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009 Page - 7




Wood Group ESP, Inc.


300 SERIES STANDARD MOTORS

3.75" / 95.25 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
7.5 6.2 410 342
10.5 8.7 390 342
315 262



AMPS
14
20.5
35.5

4-1/2" / 114.3 MM O.D. or Larger Casing
PART NUMBERS LENGTH WEIGHT
UT CT LT Ft M Lbs Kgs
113102G 6.4 1.95 208 94.4
113103G 8.3 2.53 270 122
113104G 113113G 113122G
15 12.5
19.5 16.2

22.5 18.7


25.5 21.2
400 333 28 113105G
387 322 38 113106G
630 525 23 113107G
330 275 51.5 113130G
440 367 38.5 113108G
730 608 23 113109G
370 308 51 113110G
500 417 37 113131G
630 525 30 113111G
113114G 113123G
113115G 113124G
113116G 113125G
113132G
113117G
113118G
113119G
113133G
113120G
11.1 3.38 361 164
13.9 4.24 456 207
15.8 4.82 514 233
17.7 5.39 660 299


300 SERIES THD MOTORS

3.75" / 95.25 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
10 8.3 455 380
15 12.5 455 370
25 20.8 490 405
455 380



AMPS
17
26
39
50


NUMBERS
UT CT
113287G
113288G
113292G 113293G
113295G 113296G

4-1/2" / 114.3 MM O.D. or Larger Casing
LENGTH WEIGHT
LT Ft M Lbs Kgs
6.4 1.95 208 94.4
8.3 2.53 270 122
11.1 3.38 361 164
30 25
35 29.2

40 33.3
745 620 30 113298G
520 430 51 113304G
865 730 30 113307G
595 495 49 113313G
750 625 40 113316G
13.9 4.24 456 207
113299G
113305G
15.8 4.82 514 233
113308G
113314G
17.7 5.39 660 299
113317G


DESCRIPTION PART NUMBERS
HEAD , MTR TR3-92 BOLT-ON 113268
KIT, BASE MTR TR3 Y-PT STL 1048610
KIT, INSTALLATION TR3 1054444
LENGTH WEIGHT
Ft M Lbs Kgs
1.1 0.34 28 12.7
0.5 0.15 15 6.8
NA NA 0.5 0.23




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 1


Wood Group ESP, Inc.


























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 2 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009



Wood Group ESP, Inc.


400 SERIES STANDARD MOTORS

4.56" / 115.82 MM O.D.

5-1/2" / 139.70 MM O.D. or Larger Casing
HP
60 Hz 50 Hz
10 8.7
15 12.5

20 16.5

25 20.8

30 25

35 29.2


40 33.3



50 41.7




60 50
VOLTS
60 Hz 50 Hz
435 362
435 362
610 508
450 375
750 625
410 342
690 575
810 675
425 354
750 625
400 333
675 562
750 625
420 350
770 642
880 733
1295 1079
675 562
815 679
955 796
1070 892
1210 1008
640 533
810 675
970 808
1330 1108
1945 1621
AMPS
15
23
16
28.5
17
39
22
20
44.5
25.5
55
33
28
62
33
29
20
47
39
33
31
27
59
47
39
29
20
PART NUMBERS
UT CT PLUG-IN
110752G 130296G
110753G 130297G
110699G 130298G
110754G 130299G
110755G 130300G
110756G 130320G
110757G 130615G
110700G 120387G
110758G 130616G
110759G 120388G
110760G 130617G
110761G 130618G
110762G 192355G 130619G
110763G 130620G
110764G 130621G
110765G 192352G 130622G
110766G 130623G
110767G 130624G
110768G 130625G
110769G 130626G
110770G 130627G
110771G 120389G
110772G 110809G 130628G
110773G 110810G 130629G
110774G 110811G 130630G
110775G 110812G 120861G
110776G 130631G
LENGTH WEIGHT
Ft M Lbs Kgs
4.1 1.25 240 109
5.3 1.62 288 131
6.5 1.98 345 156
7.7 2.35 402 183
8.9 2.71 462 210
10.1 3.08 520 236
11.3 3.44 577 262
13.7 4.18 694 315
16.5 5.03 810 367






DESCRIPTION PART NUMBERS
HEAD , MTR TR4 BO ASSY 110669
KIT, BASE MTR TR4 BO Y-PT STL 1008109
KIT, INSTALLATION TR4 1054451
LENGTH WEIGHT
Ft M Lbs Kgs
1.3 0.4 32 14.5
1 0.3 21 9.53
NA NA 0.21 0.1




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 3



Wood Group ESP, Inc.


400 SERIES STANDARD MOTORS continued

4.56" / 115.82 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
540 450
750 625
70 58.3 945 787
1135 946
1310 1092
635 529
860 717
80 66.7 1085 904
1310 1092
2155 1796
710 592
960 800
1135 946



AMPS
82.5
60
47
39
35
80
60
46
39
24
81
59
50

5-1/2" / 139.70 MM O.D. or Larger Casing
PART NUMBERS LENGTH WEIGHT
UT CT PLUG-IN Ft M Lbs Kgs
110777G 110813G 130632G
110778G 110814G 130633G
110779G 110815G 130634G 18.4 5.61 885 402
110780G 110816G 120390G
110781G 110817G 130635G
110782G 110818G 130636G
110783G 110819G 130637G
110784G 110820G 130638G 20.8 6.34 994 451
110785G 110821G 130639G
110786G 130640G
110787G 110822G 130641G
110788G 110823G 130642G
110789G 110824G 130643G
90 75




100 83.3


110 91.7


120 100
1220
1460
1930
775
1075
1355
2205
1190
2380
930
1040
1125
1295
2245
1017 46 110792G
1217 39 110790G
1608 31 110791G
646 84 110793G
896 59 110794G
1129 46 110795G
1837 28.5 110796G
992 60 110797G
1983 30 110798G
775 84 110799G
867 76 110800G
937 70 110801G
1079 59 110802G
1871 35 110803G
110826G 130644G
110825G 130239G
130240G
110827G 130257G
110828G 130258G
110829G 120447G
130259G
110830G 130260G
130275G
110831G 130276G
110832G 130277G
110833G 130278G
110834G 130279G
130280G
23.2 7.07 1115 506
25.6 7.8 1295 588
28 8.53 1395 632
30.4 9.27 1500 681






DESCRIPTION PART NUMBERS
HEAD , MTR TR4 BO ASSY 110669
KIT, BASE MTR TR4 BO Y-PT STL 1008109
KIT, INSTALLATION TR4 1054451
LENGTH WEIGHT
Ft M Lbs Kgs
1.3 0.4 32 14.5
1 0.3 21 9.53
NA NA 0.21 0.1




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 4 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009



Wood Group ESP, Inc.


400 SERIES THD MOTORS

4.56" / 115.82 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
15 12.5 505 421
20 16.5 675 562
30 25 870 725
780 650



AMPS
20
20
23
28

5-1/2" / 139.70 MM O.D. or Larger Casing
PART NUMBERS LENGTH WEIGHT
UT CT Ft M Lbs Kgs
120255G 4.1 1.25 240 108.9
120257G 5.3 1.62 288 131
120259G 6.5 1.98 345 155
120261G
35

45

50

60

75

90

105

120

135

150

165

180
29.2
37.5

41.7

50

62.5

74.7

87.5

100

112.5

125

137.5

150
915 762
495 412
870 725
770 642
885 737
1020 850
1505 1254
1245 1037
1410 1175
1540 1283
2260 1883
1320 1100
1520 1267
1520 1267
2505 2087
1700 1417
2240 1867
1575 1312
2560 2133
1380 1150
2770 2308
1505 1254
2610 2175
7.7 2.35 402
25 120262G
59 120263G
8.9 2.71 462
34 120264G
42 120265G
10.1 3.08 520
36 120266G
39 120269G
11.3 3.44 577
27 120270G
41 120274G
13.7 4.18 694
36 120275G
39 120279G 120311G
16.5 5.03 810
27 120280G
52 120284G 120315G
18.4 5.61 885
47 120285G 120316G
52 120289G 120320G
20.8 6.34 994
32 120290G
52 120295G 120325G
23.2 7.07 1115
41 120296G
61 120299G 120328G
25.6 7.8 1295
38 120300G
80 120301G 120329G
28 8.53 1395
40 120302G
79 120306G 120333G
30.4 9.27 1500
47 120307G
183
210
236
262
315
368
402
451
506
588
633
681





DESCRIPTION PART NUMBERS
Head, MTR TR4 BO ASSY 110669
KIT, BASE MTR TR4 BO Y-PT STL 1008109
KIT INSTALLATION TR4 1054451
LENGTH WEIGHT
Ft M Lbs Kgs
1.3 0.4 32 14.52
1 0.3 21 9.53
NA NA 0.21 0.1




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 5



Wood Group ESP, Inc.


























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 6 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009



Wood Group ESP, Inc.


500 SERIES STANDARD MOTORS

5.44" / 138.20 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D)
HP VOLTS NUMBERS

6-5/8" / 168.28 MM O.D. or Larger
LENGTH WEIGHT
60 Hz 50 Hz

20 16.7


30 25


40 33.3



50 41.7





60 50



70 58.3


80 66.7
60 Hz
440
755
1020
435
710
1215
435
730
880
1325
450
725
905
1270
1375
425
645
870
970
1085
1320
755
1015
1215
865
1160
2180
AMPS
50 Hz UT
367 29 111807G
629 17 111808G
850 12 111809G
362 45 111810G
592 28 111811G
1012 16 111812G
362 60 111813G
608 36 111814G
733 30 111815G
1104 20 111816G
375 72 111817G
604 45 111818G
754 35 111819G
1058 25 111820G
1146 22 111821G
354 91 111822G
537 59 111823G
725 45 111824G
808 40 111825G
904 35 111826G
1100 30 111827G
629 60 111829G
846 45 111830G
1054 35 111831G
721 60 111832G
967 45 111833G
1817 23 111834G
CT PLUG-IN
131217G
Ft M Lbs Kgs
5 1.52 300 137
6.3 1.92 390 177
7.7 2.35 483 219
9.1 2.77 575 261
10.5 3.2 678 308
11.8 3.6 770 349
13.2 4.02 862 391






DESCRIPTION PART NUMBERS
Head, MTR TR5 UT BO ASSY 111906
KIT, BASE MTR TR5BO Y-PT STL 1017318
KIT INSTALLATION TR5 1054469
LENGTH WEIGHT
Ft M Lbs Kgs
1.3 0.42 81 36.7
0.75 0.23 26 11.8
NA NA 1.3 0.6




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 7


Wood Group ESP, Inc.


500 SERIES STANDARD MOTORS continued

5.40" / 137.16 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) 6-5/8" / 168.28 MM O.D. or Larger
HP
60 Hz 50 Hz


100 83.3



120 100


130 108.3

140 116.7


150 125


160 133.3



180 150


200 166.7

225 187.5
VOLTS
60 Hz 50 Hz
705 587
835 696
1070 892
1255 1046
2170 1808
855 712
1030 858
1295 1079
2165 1804
925 771
1125 937
985 821
1210 1008
2015 1679
1075 896
1240 1033
2105 1754
825 687
1115 929
2003 1699
2185 1821
945 787
1275 1062
1945 1621
2260 1883
1100 917
2140 1783
1135 946
2235 1862
AMPS
90
76
60
50
29
88
73
59
33
88
73
90
67
44
87
76
44
122
88.5
50
46
120
89
59
50
115
54
127
64
PART NUMBERS
UT CT PLUG-IN
111835G
111836G 111988G
111837G 111989G
111838G 111990G 131218G
111839G 131385G
111840G 111991G
111841G 111992G
111842G 111993G 131219G
111843G
111844G 111994G
111845G 111957G
111846G 111958G
111847G 111959G
111848G 131096G
111849G 111995G
111850G 111996G 131097G
111851G
111852G 111961G
111853G 111962G
111854G
111855G
111856G 111963G
111857G 111964G 131220G
111858G 131098G
111859G
111860G 111997G
111861G 131099G
111862G 111998G
111863G 131310G
LENGTH WEIGHT
Ft M Lbs Kgs


15.9 4.85 1047 471



18.7 5.7 1232 554


19.9 6.07 1287 585

21.4 6.52 1417 644


22.8 6.95 1514 688


24.2 7.38 1620 736



26.9 8.2 1833 833


29.6 9.02 2018 917

29.6 9.02 2018 917



DESCRIPTION PART NUMBERS
Head, MTR TR5 UT BO ASSY 111906
KIT, BASE MTR TR5BO Y-PT STL 1017318
KIT INSTALLATION TR5 1054469
LENGTH WEIGHT
Ft M Lbs Kgs
1.3 0.42 81 36.7
0.75 0.23 26 11.8
NA NA 1.3 0.6




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 8 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009


Wood Group ESP, Inc.


500 SERIES THD MOTORS

5.40" / 137.16 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
510 425



AMPS
37


NUMBERS
UT CT
121155G

6-5/8" / 168.28 MM O.D. or Larger
LENGTH WEIGHT
PLUG-IN Ft M Lbs Kgs
30
45

60

75

90

105

120

150

180
195
210

225

240

270

300
25
37.5

50

62.5

75

87.5

100

125

150
162.5
175

187.5

200

225

250
1190 992 15 121157G
510 425 58 121158G
1420 1183 21 121160G
1025 854 39 121163G
1545 1287 26 121164G
1055 879 45 121167G
1600 1333 28 121169G
1130 942 52 121173G
1540 1283 39 121176G
1180 983 58 121178G
1475 1229 45 121179G
1350 1125 58 121181G
2540 2117 30 121182G
1460 1217 65 121186G
2350 1958 37 121187G
1200 1000 94 121189G
2525 2104 43 121191G
1310 1092 87 121193G
1150 958 116 121194G
2350 1958 57 121196G
1250 1042 112 121197G
2455 2046 57 121199G
1300 1083 114 121201G
2550 2125 59 121203G
1490 1242 115 121205G
2640 2200 65 121207G
1280 1067 148 121208G
2500 2083 70 121998G
5 1.52 300
6.3 1.92 390

7.7 2.35 483

9.1 2.77 575

10.5 3.2 678

11.8 3.6 770

13.2 4.02 862
121211G
15.9 4.85 1047
121213G
18.7 5.7 1232
121216G 19.9 6.07 1287
121217G
21.4 6.52 1417
121219G
22.8 6.95 1514
121222G
24.2 7.38 1620
121224G
26.9 7.92 1833
121225G
29.6 9.02 2018
136
177
220
261
307
649
391
475
559
584
643
687
735
832
915



DESCRIPTION PART NUMBERS
Head, MTR TR5 UT BO ASSY 111906
KIT, BASE MTR TR5BO Y-PT STL 1017318
KIT INSTALLATION TR5 1054469
LENGTH WEIGHT
Ft M Lbs Kgs
1.3 0.42 81 36.7
0.75 0.23 26 11.8
NA NA 1.3 0.6




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 9

































































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 10 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009


Wood Group ESP, Inc.


E37 SERIES MOTOR

3.75" / 95.25 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
45 37.5 730 608.3
75 62.5 1200 1000
850 708.3



AMPS
48
48.5
80

4-1/2" / 114.3 MM O.D. or Larger Casing
PART NUMBERS LENGTH WEIGHT
UT CT Ft M Lbs Kgs
172088G 172083G 16 4.9 685 311
172105G 172092G 24.4 7.4 1076 488
172043G 172044G
90 75
1150 958.3 53 172109G
29.1 8.9 1294 587
172111G



DESCRIPTION
BASE, MOTOR E37 BOLT ON FILTER ASSY STL
BASE, MOTOR E37 BOLT ON FILTER ASSY CR
BASE, MOTOR E37 BO FLTR TO SNR ASSY STL*
BASE, MOTOR E37 BO FLTR TO SNR ASSY CR


PART LENGTH WEIGHT
NUMBERS Ft M Lbs Kgs
172052 1.7 0.52 26 11.8
172053 1.7 0.52 26 11.8
172054 1.7 0.52 29 13.2
172055 1.7 0.52 29 13.2
*Special filter base used to attach TR3 sensors


DESCRIPTION
HEAD, MOTOR E-37 W/LP STL CT BO ASSY*
HEAD, MOTOR E37 W/LP CR CT BO ASSY*
HEAD, MOTOR E37 NLP STL CT BO ASSY**
HEAD, MOTOR E37 NLP CR CT BO ASSY**
* For conversiont CT to UT motors with lock plates
** For conversion CT to UT motors without lock plates


DESCRIPTION
KIT, ADAPTER TR4 SEAL/E37 MTR STL
KIT, ADAPTER TR4 SEAL/E37 MTR 4SS
PART LENGTH WEIGHT
NUMBERS Ft M Lbs Kgs
172045 1.2 0.37 32.5 14.7
172046 1.2 0.37 32.5 14.7
172116 1.2 0.37 32 14.5
172117 1.2 0.37 32 14.5
PART LENGTH WEIGHT
NUMBERS Ft M Lbs Kgs
172112 NA NA NA NA
172113 NA NA NA NA


Additional Field Service Tool required
DESCRIPTION
TOOL, ALIGNMENT TDM INVL SPLN E37
PART LENGTH WEIGHT
NUMBERS Ft M Lbs Kgs
T9179 NA NA NA NA






Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 11











Typical E-37 Motor Performace at 60 Hertz
3,600 120



3,500 100
Speed
% Amps


3,400
Power factor


80
Efficiency


3,300 60



3,200 40



3,100 20



3,000 0
20 40 60 80 100 120
% Rated Load












Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 12 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009



Wood Group ESP, Inc.


E56 SERIES MOTOR

5.62" / 142.75 MM O.D.
HP VOLTS
60 Hz 50 Hz 60 Hz 50 Hz
200 166.7 1403 1169
250 208.3 1754 1462
1744 1453



AMPS
UT
86 123760
86 123768
104 123774

7" / 177.8 MM O.D. or Larger Casing
PART NUMBERS LENGTH WEIGHT
CT Ft M Lbs Kgs
123882 16.7 5.1 1168 531
123890 20.2 6.2 1413 642
123896
300 250

350 291.7

400 333.3
450 375
2105 1754 86 123775
2034 1695 104 123779
2455 2046 86 123780
2325 1937 104 123782
2806 2338 86 123783
2616 2180 104 123907
23.7 7.2 1680 764
123897
123901
27.2 8.3 1934 879
123902
123904 30.8 9.4 2195 998
30.6 9.33 2195 998
34.2 10.4 2450 111
500 416.7 TBD



DESCRIPTION
HEAD, MOTOR E56 UT BO ASSY LH
BASE, MOTOR E56 BO W/FILTER ASSY*
BASE, MOTOR E56 BO BASE, SENSOR WIRE
FILTER ASSY**


PART LENGTH WEIGHT
NUMBERS Ft M Lbs Kgs
123811 1.5 0.5 88 40
123651 2.1 0.6 65 30

153172 2.1 0.6 65 30
* Equivalent of universal motor base, only with filter section.
** Special filter base used to attach TR5 Sensors
























Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 13



Wood Group ESP, Inc.


























































Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 14 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009


3.75" / 95.25 MM O.D.
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
7.5 6.2 410 342 14 6.4 1.95 208 94.35
10.5 8.7 390 342 20.5 8.3 2.53 270 122.5
315 262 35.5
400 333 28
387 322 38
630 525 23
330 275 51.5
440 367 38.5
730 608 23
370 308 51
500 417 37
630 525 30
3.75" / 95.25 MM O.D.
T NUMBERS LENGTH WEIGHT
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
10 8.3 455 380 17 6.4 1.95 208 94.35
15 12.5 455 370 26 8.3 2.53 270 122.5
25 20.8 490 405 39 11.1 3.38 361 163.8
455 380 50
745 620 30
520 430 51
865 730 30
595 495 49
750 625 40
Ft M Lbs Kgs
1.1 0.34 28 12.7
0.5 0.15 15 6.8
NA NA 0.5 0.23
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
DESCRIPTION
PART
NUMBERS
LENGTH WEIGHT
25 30
HP
300 SERIES HTI - THD MOTORS
206.8 456
33.3 40
29.2 35
4.24
660
113803G
113349G
113436G
113802G
113350G
113437G
16.2
12.5 3.38
456 4.24
11.1 361
113355G
163.8
660 5.39
514 4.82
206.8
113354G
103127G 103128G
300 SERIES HTI MOTORS
HP VOLTS
AMPS
PART NUMBERS LENGTH WEIGHT
UT CT
299.4
233.2 514
17.7
15.8
5.39
4.82
13.9
1054444
1048610
113268
KIT, INSTALLATION TR3
KIT, BASE MTR TR3 Y-PT STL
HEAD , MTR TR3-92 BOLT-ON
103129G
113476G
103130G
15.8
13.9
299.4
233.2
15
19.5
17.7
VOLTS
AMPS
22.5 18.7
21.2 25.5
UT CT
113478G
Wood Group ESP, Inc.
Page - 1
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 2 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
4.56" / 115.82 MM O.D. 5-1/2" / 139.70 MM O.D. or Larger Casing
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
10 8.7 435 362 15 4.1 1.25 240 109
435 362 23
610 508 16
450 375 28.5
750 625 17
410 342 39
690 575 22
810 675 20
425 354 44.5
750 625 25.5
400 333 55
675 562 33
750 625 28
420 350 62
770 642 33
880 733 29
1295 1079 20
675 562 47
815 679 39
955 796 33
1070 892 31
1210 1008 27
640 533 59
810 675 47
970 808 39
1330 1108 29
1945 1621 20
Ft M Lbs Kgs
1.3 0.4 32 14.5
1 0.3 21 9.53
NA NA 0.21 0.1
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
15 12.5
6.5
210 462 2.71 8.9
183 402
156 345 1.98
520 3.08
131
315 694
236
262 577 3.44
130019G
130020G
130014G
130018G
130017G
130016G
130015G
41.7
33.3 40
50
130012G
130011G
LENGTH WEIGHT
192694G 130041G
192529G
HP VOLTS
AMPS
PART NUMBERS
KIT, BASE MTR TR4 BO Y-PT STL 1008109
KIT, INSTALLATION TR4 1054451
PART NUMBERS
LENGTH WEIGHT
HEAD , MTR TR4 BO ASSY 110669
DESCRIPTION
130025G
130024G
50 60 130023G
130022G
130021G
130040G
130039G
130038G
367 810 5.03 16.5
400 SERIES HTI MOTORS
UT CT PLUG-IN
288 1.62
130001G
5.3
11.3
4.18 13.7
7.7 2.35
130362G
130568G
130013G
192530G
192601G
192528G
130002G
130003G 192597G
130010G
130005G
35
16.5 20
130004G
30
25
29.2
130007G
25
20.8
130008G
10.1
192599G 130006G
130009G
Page - 3
Wood Group ESP, Inc.
4.56" / 115.82 MM O.D. 5-1/2" / 139.70 MM O.D. or Larger Casing
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
540 450 82.5
750 625 60
945 787 47
1135 946 39
1310 1092 35
635 529 80
860 717 60
1085 904 46
1310 1092 39
2155 1796 24
710 592 81
960 800 59
1135 946 50
1220 1017 46
1460 1217 39
1930 1608 31
775 646 84
1075 896 59
1355 1129 46
2205 1837 28.5
1190 992 60
2380 1983 30
930 775 84
1040 867 76
1125 937 70
1295 1079 59
2245 1871 35
Ft M Lbs Kgs
1.3 0.4 32 14.5
1 0.3 21 9.53
NA NA 0.21 0.1
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 4 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
130503G
130043G
192376G 130546G 130505G
130027G
130044G 130028G
130545G 130504G
120855G
130034G
130507G
192533G 130547G 130506G
130509G
192452G 130548G 130508G
130550G 130529G
130549G 130528G
130042G 130026G
130543G
192532G 120954G 120689G
130030G
130029G
25.6 588 1295 7.8
451 994 6.34 20.8
506 1115 7.07 23.2
632
PLUG-IN
70 402 885 5.61 18.4 58.3
130046G
400 SERIES HTI MOTORS continued
HP VOLTS
AMPS
PART NUMBERS LENGTH WEIGHT
UT CT
1395 8.53 28 91.7
100 120
130053G
83.3
110
130054G 130036G
130563G 130530G 681 1500 9.27 30.4
120687G
130032G
192691G
75 90
192531G 130544G 130502G
130035G
130049G 130033G
130047G 130031G
66.7 80
LENGTH
130037G
192595G
100
130055G
WEIGHT
192594G 130045G
120691G
120856G
130048G
KIT, BASE MTR TR4 BO Y-PT STL 1008109
DESCRIPTION PART NUMBERS
KIT, INSTALLATION TR4 1054451
HEAD , MTR TR4 BO ASSY 110669
Wood Group ESP, Inc.
4.56" / 115.82 MM O.D. 5-1/2" / 139.70 MM O.D. or Larger Casing
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
15 12.5 505 421 20 4.1 1.25 240 108.9
20 16.5 675 562 20 5.3 1.62 288 131
30 25 870 725 23 6.5 1.98 345 155
780 650 28
915 762 25
495 412 59
870 725 34
770 642 42
885 737 36
1020 850 39
1505 1254 27
1245 1037 41
1410 1175 36
1540 1283 39
2260 1883 27
1320 1100 52
1520 1267 47
1525 1270 52
2505 2087 32
1695 1412 52
2240 1867 41
1575 1312 61
2565 2133 38
1385 1154 80
2765 2304 40
1505 1254 79
2610 2175 47
Ft M Lbs Kgs
1.3 0.4 32 14.52
1 0.3 21 9.53
NA NA 0.21 0.1
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
HP VOLTS
35 29.2
45 37.5
CT
400 SERIES HTI - THD MOTORS
PART NUMBERS LENGTH WEIGHT
AMPS
UT
50 41.7
60 50
75
180
165
150
135
120
105
90
150
137.5
125
112.5
140275G
140271G
140270G
140267G
140262G
140331G
140329G
140325G
140324G
140323G
140322G
140319G
140318G
140313G
140312G
140258G
140257G
140253G
140308G
140307G
140303G
140302G
140298G
140297G
140293G
140292G
140289G
140288G
140286G
140285G
140284G
140283G
140281G
140279G
140277G
183 402 2.35 7.7
8.9 2.71 462 210
10.1 3.08 520 236
11.3 3.44 577 262
13.7 4.18 694 315
16.5 5.03 810 368
18.4 5.61 885 402
20.8 6.34 994 451
23.2 7.07 1115 506
8.53 1395 633
25.6 7.8 1295 588
WEIGHT
Wood Group ESP, Inc.
Page - 5
30.4 9.27 1500 681
28
KIT INSTALLATION TR4
KIT, BASE MTR TR4 BO Y-PT STL
Head, MTR TR4 BO ASSY
100
87.5
74.7
62.5
LENGTH
DESCRIPTION PART NUMBERS
1054451
1008109
110669
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 6 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
5.44" / 138.20 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) 6-5/8" / 168.28 MM O.D. or Larger
T NUMBERS LENGTH WEIGHT
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
440 367 29
755 629 17
1020 850 12
435 362 45
710 592 28
1215 1012 16
435 362 60
730 608 36
880 733 30
1325 1104 20
450 375 72
725 604 45
905 754 35
1270 1058 25
1375 1146 22
425 354 91
645 537 59
870 725 45
970 808 40
1085 904 35
1320 1100 30
755 629 60
1015 846 45
1265 1054 35
865 721 60
1160 967 45
2180 1817 23
Ft M Lbs Kgs
1.3 0.42 81 36.7
0.75 0.23 26 11.8
NA NA 1.3 0.6
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
70
80
5
6.3
7.7
9.1
30
11.8
13.2
121871G
60 10.5
2.77
121863G
40
50
2.35 483
20 1.52 300
1.92 390
3.2 678
3.6 770
4.02 862
575
121868G
121874G
121873G
121872G
121875G 161358G
121870G
121869G
121876G
121878G
121786G
121877G
121883G
121882G
121881G
121879G
121884G
PART NUMBERS
151524G
136193G
121886G
121707G
121885G
121866G
121865G
121864G
500 SERIES HTI MOTORS
VOLTS HP
AMPS
PLUG-IN CT UT
121862G
121861G
25
16.7
391
349
308
261
219
177
137
66.7
33.3
58.3
50
41.7
121867G
Page - 7
DESCRIPTION
Head, MTR TR5 UT BO ASSY
KIT, BASE MTR TR5BO Y-PT STL
KIT INSTALLATION TR5
1017318
1054469
LENGTH WEIGHT
111906
Wood Group ESP, Inc.
5.40" / 137.16 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) 6-5/8" / 168.28 MM O.D. or Larger
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
705 587 90
835 696 76
1070 892 60
1255 1046 50
2170 1808 29
855 712 88
1030 858 73
1295 1079 59
2165 1804 33
925 771 88
1125 937 73
985 821 90
1210 1008 67
2015 1679 44
1075 896 87
1240 1033 76
2105 1754 44
825 687 122
1115 929 88.5
2003 1699 50
2185 1821 46
945 787 120
1275 1062 89
1945 1621 59
2260 1883 50
1100 917 115
2140 1783 54
1135 946 127
2235 1862 64
Ft M Lbs Kgs
1.3 0.42 81 36.7
0.75 0.23 26 11.8
NA NA 1.3 0.6
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 8 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
151397G
132673G
121917G
133.3
161357G
121915G
131757G
151811G
141853G
121911G
121912G
121914G
121913G
121916G
121926G
121921G
121924G
121925G
121702G
121922G
121923G
121928G
161361G
121897G
121711G
121898G
121899G
121918G
121919G
121920G
125
KIT INSTALLATION TR5
130
120
121909G
121701G
121910G
121906G
121907G
121908G
121904G
121905G
121713G
121900G
121901G
121715G
121902G
121903G
DESCRIPTION PART NUMBERS
LENGTH
PLUG-IN
500 SERIES HTI MOTORS continued
PART NUMBERS LENGTH WEIGHT
140
WEIGHT
Head, MTR TR5 UT BO ASSY 111906
KIT, BASE MTR TR5BO Y-PT STL 1017318
1054469
Wood Group ESP, Inc.
HP VOLTS
AMPS
UT CT
121895G
121896G
100
225
200
180
160
150
83.3
100
108.3
116.7
150
166.7
187.5
15.9
18.7
19.9
21.4
22.8
24.2
26.9
29.6
29.6
4.85
5.7
6.07
6.52
6.95
7.38
8.2
9.02
9.02
1047
1232
1287
1417
1514
1620
1833
2018
2018
471
554
585
644
688
736
833
917
917
121887G
121888G
121889G
121709G
121890G
121891G
121892G
121893G
121894G
151812G
136446G
151400G
5.40" / 137.16 MM O.D. 6-5/8" / 168.28 MM O.D. or Larger
T NUMBERS LENGTH WEIGHT
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
510 425 37
1190 992 15
510 425 58
1420 1183 21
1025 854 39
1545 1287 26
1055 879 45
1600 1333 28
1130 942 52
1540 1283 39
1180 983 58
1475 1229 45
1355 1129 58
2540 2117 30
1465 1221 65
2350 1958 37
1200 1000 94
2525 2104 43
195 162.5 1310 1092 87 19.9 6.07 1287 584
1150 958 116
2350 1958 57
1255 1046 112
2455 2046 57
1300 1083 114
2550 2125 59
1485 1238 115
2640 2200 65
1285 1067 148
2500 2083 70
Ft M Lbs Kgs
1.3 0.42 81 36.7
0.75 0.23 26 11.8
NA NA 1.3 0.6
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
VOLTS
AMPS
UT CT
HP
PLUG-IN
30 25 5
141090G
1.52 300 136
45 6.3 1.92 390 177 37.5
141088G
60
75
90
105
120
150
180
210
225
240
270
300
7.7 2.35 483 220
9.1 2.77 575 261
10.5 3.2 678 307
11.8 3.6 770 649
13.2 4.02 862 391
15.9 4.85 1047 475
18.7 5.7 1232 559
21.4 6.52 1417 643
22.8 6.95 1514 687
24.2 7.38 1620 735
2018 915
26.9 7.92 1833 832
50
62.5
75
87.5
100
125
150
175
187.5
200
225
250
141091G
141093G
141096G
141097G
141100G
141102G
141106G
141108G
141133G
141135G
141137G
141125G
141126G
141128G
141129G
141131G
141118G
141119G
141121G
141123G
141110G
141111G
141113G
141114G
141028G
141049G
141066G
141030G
141048G
141069G
141086G
DESCRIPTION PART NUMBERS
141139G
141141G
LENGTH
29.6 9.02
121395G
KIT INSTALLATION TR5 1054469
Page - 9
Wood Group ESP, Inc.
500 SERIES HTI - THD MOTORS
WEIGHT
Head, MTR TR5 UT BO ASSY 111906
KIT, BASE MTR TR5BO Y-PT STL 1017318
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 10 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
3.75" / 95.25 MM O.D. 4-1/2" / 114.3 MM O.D. or Larger Casing
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
45 37.5 587 489 53 16 4.9 685 311
75 62.5 978 815 53 24.4 7.4 1076 488
90 75 1150 958.3 53 29.1 8.9 1294 587
815
PART
NUMBERS Ft M Lbs Kgs
172052 1.7 0.52 26 11.8
172053 1.7 0.52 26 11.8
172054 1.7 0.52 29 13.2
172055 1.7 0.52 29 13.2
*Special filter base used to attach TR3 sensors
PART
NUMBERS Ft M Lbs Kgs
172045 1.2 0.37 32.5 14.7
172046 1.2 0.37 32.5 14.7
172116 1.2 0.37 32 14.5
172117 1.2 0.37 32 14.5
PART
NUMBERS Ft M Lbs Kgs
172112 NA NA NA NA
172113 NA NA NA NA
PART
NUMBERS Ft M Lbs Kgs
T9179 NA NA NA NA
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.
E37 HTI SERIES MOTOR
HP VOLTS
AMPS
PART NUMBERS LENGTH WEIGHT
UT CT
172119G
172123G
172109G 172111G
172121G
172125G
LENGTH WEIGHT
BASE, MOTOR E37 BOLT ON FILTER ASSY STL
DESCRIPTION
BASE, MOTOR E37 BOLT ON FILTER ASSY CR
BASE, MOTOR E37 BO FLTR TO SNR ASSY STL*
BASE, MOTOR E37 BO FLTR TO SNR ASSY CR
DESCRIPTION
LENGTH WEIGHT
HEAD, MOTOR E-37 W/LP STL CT BO ASSY*
HEAD, MOTOR E37 W/LP CR CT BO ASSY*
HEAD, MOTOR E37 NLP STL CT BO ASSY**
HEAD, MOTOR E37 NLP CR CT BO ASSY**
* For conversiont CT to UT motors with lock plates
** For conversion CT to UT motors without lock plates
DESCRIPTION
WEIGHT
KIT, ADAPTER TR4 SEAL/E37 MTR STL
KIT, ADAPTER TR4 SEAL/E37 MTR 4SS
LENGTH
TOOL, ALIGNMENT TDM INVL SPLN E37
Additional Field Service Tool required
Page - 11
DESCRIPTION
LENGTH WEIGHT
Typical E-37 Motor Performace at 60 Hertz
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 12 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
3,000
3,100
3,200
3,300
3,400
3,500
3,600
20 40 60 80 100 120
% Rated Load
S
p
e
e
d

(
R
P
M
)
0
20
40
60
80
100
120
%

A
m
p
s
/
E
f
i
i
c
i
e
n
c
y
/
P
o
w
e
r

F
a
c
t
o
r
Speed
Efficiency
% Amps
Power factor
5.62" / 142.75 MM O.D.
60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs
200 166.7 1403 1169 86 16.7 5.1 1168 531
250 208.3 1754 1462 86 20.2 6.2 1413 642
1744 1453 104
2105 1754 86
2034 1695 104
2455 2046 86
2325 1937 104 30.8 9.4 2195 998
2806 2338 86 30.6 9.33 2195 998
450 375 2616 2180 104 34.2 10.4 2450 111
Ft M Lbs Kgs
1.5 0.5 88 40
2.1 0.6 65 30
BASE, MOTOR E56 BO BASE, SENSOR WIRE
FILTER ASSY**
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 13
LENGTH WEIGHT
DESCRIPTION
65 30
300
350
400
Wood Group ESP, Inc.
E56 HTI - SERIES MOTOR
HP VOLTS
AMPS
PART NUMBERS LENGTH WEIGHT
UT CT
123760 123882
123768
123775
123774 123896
123890
123897
2.1
1680
123780
1934
0.6
123782
123783
123907
123904
250
291.7
* Equivalent of universal motor base, only with filter section.
** Special filter base used to attach TR5 Sensors
123779
500
333.3
416.7
764
879
TBD
27.2
7.2
8.3
23.7
HEAD, MOTOR E56 UT BO ASSY LH
BASE, MOTOR E56 BO W/FILTER ASSY*
153172
PART
NUMBERS
123811
123651
123901
123902
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 14 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009
Wood Group ESP, Inc.



Wood Group ESP, Inc.


MOTOR SHROUDS


ENCAPSULATED PUMP SYSTEM

MATERIALS OF CONTRUCTION
Two material types are available, duplex stainless steel (SS) and carbon steel (CS).
Engineering should also be consulted for applications with wellbore deviation in excess of 45 or
where the maximum dogleg severity (DS) exceeds 5/100 ft.

APPLICATION RATING
BURST
PRESSURE
Well Casing Size PSI
COLLAPSE MAXIMUM MAXIMUM
PRESSURE TENSION TEMPERATURE
PSI LBS DEGREE
MAXIMUM
O.D. INCHES
7 CASING 5,000 4,800 12,000 260 5.76
7 CASING 5,000 4,200 12,000 260 5.76
5 1/2 CASING 5,000 4,800 10,000 260 4.66
5 1/2 CASING 5,000 4,200 10,000 260 4.66
Part numbers for different sizes Encapsulated Pump System are given in table below. Since each
application will be unique, Wood Group ESPs engineering department should be consulted for the
quantity of the shroud material and other necessary components ordered.

PART NUMBER
DESCRIPTION 7SS 7CS 5 1/2 SS 5 1/2 CS
SHROUD HANGER 147019 145759 147016 145760
SHROUD TOP 147023 145761 147018 145762
HANGER SCREWS 147022 147022 147017 147017
O-RING 705247 705247 705241 705241
BACK-UP RINGS 145394 145394 145400 145400
EUE PIN 147021 145763 147024 145764
EUE PIN 147376 145766 147060 145767
SECTION 147039 145768 147042 145769
SECTION 147029 145770 147041 145771
THROUGH SYSTEM 145395 145395 145395 145395
3/8 8rd EUE 145772 145773 145772 145773
MOTOR BASE 145392 145392 145401 145401





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 2 Product Catalog - Motors / Motor Shrouds - Copyright Wood Group ESP, Inc. - October, 2009

Application Guidelines
Seal Bags
*FKM is the abbreviation of fluoroelastomers. One common fluoroelastomer is Viton, which is a trade name of
DuPont. To call all fluoroelastomers Viton is common, but incorrect and has been addressed legally by DuPont.
**EPDM, perfluoroelastomer, is also excellent in steam applications, depending on the temperature range and
chemicals.
Ratings:
Excellent Long term resistance (very low swell, maintains very high physical properties)
Good Long term resistance (moderate swell, maintains very high physical properties)
Fair Depends upon exposure time and temperature (good short term resistance)
Poor No resistance even in the short term
Note: An Application Engineer should be consulted on applications where the equipment might be
subjected to a fluid with constituents other than listed in table.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October 2009
Maximum BHT (applies
to seal sections only)
Maximum Operating
Temperature
Material HSN
175F
275F
FKM* Aflas
300F 350F
400F 450F
Chemical HSN FKM* Aflas
Water/oil Excellent Good Excellent
Carbon Dioxide (CO
2
) Good Poor Good
Steam (geothermal
applications)
Excellent Poor
Amines Fair Poor
Fair Good or Fair
Fair
Elastomer seal bags are available in three materials HSN, FKM* and Aflas. The durability of the bag
material depends on the temperature and the environment to which it is subjected. The following chart
should be followed when selecting the right bag material for well application. Wood Group ESPs standard
bag material is HSN. More robust materials are also available to meet specific applications.
Hydrogen Sulfide (H
2
S) Excellent
Excellent
Fair
Fair Excellent**
Aromatic hydrocarbon
(Xylene, Toluene, etc.)
Page - 1
Seal Section
Wood Group ESP, Inc.
Thrust Bearing Load Calculations for all Floater Pumps
Thrust Bearing Load Calculations for all Compression Pumps
Thrust Bearing Load Calculations for Combination Pumps
Thrust Bearing Selection
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 2 Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009
Compare the maximum pump thrust to the thrust bearing thrust limit. Note this is a function of temperature
and motor oil used for high load bearings. Choose a thrust bearing that has a higher thrust limit than the
thrust generated by the pump. Note compression pumps will almost always require a high load bearing and
engineering guidelines call for use of a high load bearing when installing compression pumps.
Floater pump thrust comes from the pump differential pressure operating on the cross-sectional area of the pump
shaft. To calculate maximum floater pump thrust use the following procedure:
1. Look in the engineering data section of the product catalog and locate the pump shaft area (A) in sq. in.
2. Look up the pump performance curve in the product catalog and locate the shut-in pump head (Hd) in ft/stage
at your maximum operating frequency.
3. Calculate the maximum pump thrust using: lbf = Ft/stage x .433 x SG x A x Nstages
Where: Nstages is the number of floater pump stages, SG is the pumped fluid specific gravity
3. Calculate the maximum pump thrust using: lbf = lbf/stage x Nstages
Where: Nstages = The number of compression pump stages
When you have a combination of floater and compression pump stages, calculate the thrust for each type of
pump independently and then add the results.
2. The pump thrust at different operating frequencies can be estimated from: lbf(n) = lbf(60) x (n/60) 2
Compression pump thrust comes from both the discharge pressure operating across the pump shaft area
plus the sum of the pressure differential across each pump stage acting across the stage skirt areas minus
the fluid momentum imparted on the stage by the moving fluid. The pump thrust is a function of the fluid rate
and increases as the flow rate decreases. WGESP publishes compression pump thrust at shut-in conditions
(the maximum). This published value already includes the pump shaft thrust. To calculate maximum
compression pump thrust used the following algorithm:
1. Look in the engineering data section of the product catalog. It contains the maximum compression pump
thrust in lbf/stage for both 60 and 50 Hz operation. (This is at shut-in)
Wood Group ESP, Inc.
TR3 Series
HOUSING DIAMETER 3.375 IN HOUSING DIAMETER 85.85 MM
SHAFT DIAMETER .750 IN SHAFT DIAMETER 19.05 MM
SHAFT LIMIT STANDARD 160 HP SHAFT LIMIT STANDARD 133 HP
HIGH STRENGTH 256 HP HIGH STRENGTH 213 HP
TR387 SERIES
HOUSING DIAMETER 3.87 IN HOUSING DIAMETER 98.30 MM
SHAFT DIAMETER SHAFT DIAMETER 22.23 MM
SHAFT LIMIT STANDARD 256 HP SHAFT LIMIT STANDARD 213 HP
HIGH STRENGTH 410 HP HIGH STRENGTH 342 HP
Note: High Load (HL) bearing shown using ESP #6 oil.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009
Description
SEAL,TR3 STD
SEAL,TR3 STD HL,HT
5.10
5.10
Length
Ft. M. Lbs. Kgs.
PART NO.
1.6
1.6
90.0
90.0
41
41
913020
113277
Weight
ENGINEERING DATA - TR3 SERIES
60 HZ OPERATION 50 HZ OPERATION
Description
Length Weight
PART NO.
Ft. M.
0.875
116613
SEAL,TR387 DBG PFDB STL HL-HT AFLAS 6.10 1.9 195 88 116646
SEAL,TR387 SBG PFSB STL HL-HT AFLAS 4.50
ENGINEERING DATA - TR387 SERIES
60 HZ OPERATION 50 HZ OPERATION
Lbs. Kgs.
1.4 101 46
Wood Group ESP, Inc.
Page - 3
TR3 Seal Thrust Bearing Capacities
1700
1900
2100
2300
2500
2700
2900
0 50 100 150 200 250 300 350 400
Motor Operating Temp. (F)
T
h
r
u
s
t

L
o
a
d

(
l
b
)
40, 50, 60, &
70 Hz - 2750 lb
30 Hz - 2400 lb
20 Hz - 1800 lb
TR4 Series
HOUSING DIAMETER 4.00 IN HOUSING DIAMETER 101.60 MM
SHAFT DIAMETER SHAFT DIAMETER 22.23 MM
SHAFT LIMIT STANDARD 256 HP SHAFT LIMIT STANDARD 213 HP
HIGH STRENGTH 410 HP HIGH STRENGTH 342 HP
ULTRA HIGH STRENGTH 522 HP ULTRA HIGH STRENGTH 435 HP
Note: High Load (HL) bearing shown using ESP #6 oil.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 4 Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009
130.0 59 170787
SEAL, TR4 SBG PFSB CR
4.50
SEAL,TR4 STD HL-HT 98L UHSS AFLAS 5.30 1.6
SEAL,TR4 STD HL-HT 98L UHSS
SEAL, TR4 SBG PFSB HL HT STL AFLAS
SEAL, TR4 SBG PFSB HL HT STL AR AFLAS
SEAL,TR4 DBG PFDB STL
SEAL,TR4 SBG PFSB STL 1.4
5.30 1.6
SEAL,TR4 DBG PFDB AR CR
4.50
4.50
4.50
6.10
6.10
1.4
165.0
SEAL,TR4 DBG PFDB AR HL HT 6.10
1.4
1.4
1.9
1.9
1.9
165.0
165.0
165.0
195.0
195.0
75
75
75
88
88
1008275
195.0 88
1008267
120377
130860
1008291
130853
160452
75
88 170226
SEAL,TR4 DBG PFDB HL-HT STL UHSS AFLAS
ENGINEERING DATA - TR4 SERIES
SEAL,TR4 DBG PFDB HL STL UHSS 6.10 1.9 195.0
88
60 HZ OPERATION 50 HZ OPERATION
.875 IN
PART NO.
59 140692
130.0 59 190147
59 140691
1.6 130.0
1.6 130.0
SEAL,TR4 STD HL HT 98L HSS AFLAS 5.30
Description
Length Weight
Ft. Kgs. M. Lbs.
SEAL,TR4 STD HL HT 98L AFLAS 5.30
170999 6.10 1.9 195.0
Wood Group ESP, Inc.
TR4 Seal Thrust Bearing Capacities
3000
4000
5000
6000
7000
8000
9000
0 100 200 300 400
Motor Operating Temp. (F)
T
h
r
u
s
t

L
o
a
d

(
l
b
)
70 Hz - 8800 lb
60 Hz - 7000 lb
50 Hz - 5800 lb
40 Hz - 4800 lb
30 Hz - 4000 lb
20 Hz - 3200 lb
SEAL, TR5 SBG PFSB STL HL HT AFLAS
SEAL, TR5 DBG PFDB STL
SEAL, TR5 DBG PFDB STL HL HSN
SEAL, TR5-AR DBG PFDB HL STL HSN
SEAL, TR5 DBG PFDB STL HL HT AFLAS
SEAL, TR5-AR B/L HL STL AFLAS
SEAL,TR5-AR B/L HL-HT SST H&B HSS
SEAL, TR5-AR 2BP/2L HL STL HSN
SEAL, TR5-AR 2BP/2L HL STL AFLAS
HOUSING DIAMETER 5.125 IN HOUSING DIAMETER 136.50 MM
SHAFT DIAMETER 1.188 IN SHAFT DIAMETER 30.20 MM
AR SHAFT DIAMETER 1.375 IN AR SHAFT DIAMETER 34.90 MM
SHAFT LIMIT STANDARD 637 HP SHAFT LIMIT STANDARD 531 HP
HIGH STRENGTH 1019 HP HIGH STRENGTH 849 HP
AR SHAFT LIMIT STANDARD 637 HP AR SHAFT LIMIT STANDARD 531 HP
HIGH STRENGTH 1019 HP HIGH STRENGTH 849 HP
Note: High Load (HL) bearing shown using ESP #6 oil.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009
SEAL,TR5-AR L/2BP HL-HT PFU SST H&B HSS
SEAL,TR5-AR L/2BP HL-HT AFLAS HSS
4.40
6.30
5.60
4.40
141457
Description
Ft.
Length
SEAL, TR5-AR LBYR HL 2CH STL HSN
SEAL, TR5 SBG PFSB STL
M.
Weight
PART NO.
Lbs. Kgs.
1019611
1.3
1.9
200.0
250.0
91
113
121433
141595
6.30
6.30
2.9
3.9
250.0
250.0
1.7
1.3
1.7
121741 4.9 250.0
113
113
113
230.0
548063
548279
548490
200.0
141238
141812
240.0
230.0
420.0
420.0
420.0
420.0
540112
104
91
548083
6.30
5.60
5.60
9.12
9.12
9.70
9.70
548220
1019595
9.70 SEAL,TR5-AR 2BP/2L HL HSN STL HSS LH
1.7
1.7
2.8
2.8
3.0
SEAL,TR5-AR L/L HL-HT STL SST HB HSS 5.60 230.0 104 548065
3.0
3.0 420.0
109
104
190
190
190
190
190
50 HZ OPERATION 60 HZ OPERATION
ENGINEERING DATA - TR5 SERIES
TR5 SERIES
Wood Group ESP, Inc.
Page - 5
TR5 Seal Thrust Bearing Capacities
4000
5000
6000
7000
8000
9000
10000
11000
12000
0 50 100 150 200 250 300 350 400
Motor Operating Temp. (F)
T
h
r
u
s
t

L
o
a
d

(
l
b
)
70 Hz - 10400 lb
60 Hz - 11600 lb
50 Hz - 9200 lb
40 Hz - 8000 lb
30 Hz - 6000 lb
20 Hz - 4200 lb
TR562 SERIES
HOUSING DIAMETER 5.125 IN HOUSING DIAMETER 136.50 MM
SHAFT DIAMETER SHAFT DIAMETER 34.93 MM
SHAFT LIMIT STANDARD 690 HP SHAFT LIMIT STANDARD 575 HP
HIGH STRENGTH 1100 HP HIGH STRENGTH 917 HP
Note: High Load (HL) bearing shown using ESP #6 oil.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page - 6 Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009
Description
SEAL,TR562-AR 2BP/2L HL HSN STL HSS
CCW, LEFT HAND THREAD
ENGINEERING DATA - TR562 SERIES
190 548301
60 HZ OPERATION 50 HZ OPERATION
PART NO.
Ft. M. Lbs. Kgs.
190 548302
3.01 420.0 9.90
9.90 3.01 420.0
1.375 IN
SEAL,TR562-AR 2BP/2L HL HSN SST HD
CCW, HSS, SST HEAD ONLY, LEFT HAND
THREAD
Wood Group ESP, Inc.
Length Weight
TR562 Seal Thrust Bearing Capacities
7000
9000
11000
13000
15000
17000
19000
21000
23000
25000
0 100 200 300 400
Motor Operating Temp. (F)
T
h
r
u
s
t

L
o
a
d

(
l
b
)
70 Hz - 24000 lb
60 Hz - 20800 lb
50 Hz - 16800 lb
40 Hz - 14000 lb
30 Hz - 11200 lb
20 Hz - 8000 lb




Wood Group ESP, Inc.

SMARTGUARD SENSORS
Surface Unit Options - available options for the surface interface unit
DESCRIPTION PART NUMBER
OPTION, EVENT LOG EXPANSION 129134
OPTION, MEMORY EXPANSION, 7 DAY 129119
OPTION, MEMORY EXPANSION, 14 DAY 129120
OPTION, MEMORY EXPANSION, 35 DAY 129121
OPTION, I/O EXPANSION 129125
OPTION, RADIO / RS485 MULTI-DROP COMMUNICATIONS 129122


Downhole Sub-Assemblies - replacement parts - does not include motor adapter heads
SmartGuard III

SmartGuard V

SmartGuard VI
DOWNHOLE SUB-ASSEMBLY, STL 140470
DOWNHOLE SUB-ASSEMBLY, SST 140471
DOWNHOLE SUB-ASSEMBLY, STL 800758
DOWNHOLE SUB-ASSEMBLY, SST 800759
DOWNHOLE SUB-ASSEMBLY, STL 800777
DOWNHOLE SUB-ASSEMBLY, SST 800778


Motor Adapter Heads - replacement parts - does not include the downhole sub-assemblies
HEAD, SMARTGUARD TR3 ASSY, STL 800462
HEAD, SMARTGUARD TR3 ASSY, SST 800459
HEAD, SMARTGUARD TR4 ASSY, STL 800463
HEAD, SMARTGUARD TR4 ASSY, SST 800460
HEAD, SMARTGUARD TR5 ASSY, STL 800464
HEAD, SMARTGUARD TR5 ASSY, SST 800461
X-OVER, SMARTGUARD TO CENTRILIFT MTR, STL 800489
X-OVER, SMARTGUARD TO CENTRILIFT MTR, SST 800525


Complete Systems - assembled with minimum parts required for service


SmartGuard III
TR3 SMARTGUARD III SYSTEM, STL 113626
TR3 SMARTGUARD III SYSTEM, SST 113627
TR4 SMARTGUARD III SYSTEM, STL 160476
TR4 SMARTGUARD III SYSTEM, SST 160477
TR5 SMARTGUARD III SYSTEM, STL 157061
TR5 SMARTGUARD III SYSTEM, SST 157062

Pump Discharge Subs and Auxiliary Equipment
SUB, DISCHARGE 2 7/8, STL 800620
SUB, DISCHARGE 2 7/8, SST 800629
SUB, DISCHARGE 3 1/2, SST 800677
SmartGuard VI SUB, DISCHARGE 4 1/2, STL 800751
SUB, DISCHARGE 5 1/2", STL, BUTTRESS THREAD 800750
VALVE, FLOW 1/4 MALE - 1/4, SWAGELOK 800646
TUBING, 0.250 OD X 0.049 WL, 316 SST SPECIFY LENGTH 800602
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Downhole Sensing Systems - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
MOTOR LEAD CABLE
300 SERIES
DESCRIPTION SIZE



CABLE,MLC TR3 KELTB #6
TYPE
ARMOR


MONEL
Length Weight
PART NO.
Ft. M. Lbs. Kgs.
30 9.14 25 11.34 113388
40 12.19 33 14.97 113389
55 16.76 45 20.41 113390
70 21.34 58 26.31 113391
90 27.43 74 33.57 113392
110 33.53 91 41.28 113393

400 SERIES
DESCRIPTION SIZE


CABLE,MLC TR4 HT PLUG-IN
KELB

#6


CABLE,MLC TR4 HT KELB
TYPE
ARMOR





MONEL
Length Weight
PART NO.
Ft. M. Lbs. Kgs.
30 9.14 31 14.06 458543
42 12.80 43 19.50 458544
58 17.68 60 27.22 458545
74 22.56 76 34.47 458546
95 28.96 98 44.45 458547
110 33.53 113 51.26 458548
30 9.14 31 14.06 136719
40 12.19 41 18.60 136720
55 16.76 57 25.86 136721
70 21.34 72 32.66 136722
90 27.43 93 42.18 136723
110 33.53 113 51.26 136724

500 SERIES
DESCRIPTION SIZE


CABLE,MLC TR5 HT PLUG-IN
KELB

#4


CABLE,MLC TR5 HT KELB
TYPE
ARMOR





MONEL
Length Weight
PART NO.
Ft. M. Lbs. Kgs.
30 9.14 38 17.24 151557
42 12.80 54 24.49 151558
58 17.68 74 33.57 151559
74 22.56 95 43.09 151560
95 28.96 122 55.34 151561
110 33.53 141 63.96 151562
30 9.14 38 17.24 145016
40 12.19 51 23.13 145017
55 16.76 70 31.75 145018
70 21.34 90 40.82 145019
90 27.43 115 52.16 145020
110 33.53 141 63.96 145021



Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009 Page-1




Wood Group ESP, Inc.
CABLE

DESCRIPTION
WIRE
SIZE

CONSTRUCTION INSULATION

JACKET ARMOR DIMENSION
WEIGHT PART
Lbs/Ft NO.
FLAT PL190 3KV 16MM2 Solid PP PP GALV 0.54 x 1.37 0.85 741064
#1 0.73 x 1.92 1.70 145809
FLAT PL205 5KV #2 Solid PP NBR GALV 0.70 x 1.83 1.40 145808
#4 0.64 x 1.67 1.10 145864
FLAT PL225 5KV
#2
#4
Solid PP
0.67 x 1.74
LEAD GALV
0.61 x 1.58
2.00 155000
1.60 136800
#1 0.65 x 1.69 2.10 145819
FLAT PL450 5KV #2 Solid EPDM LEAD GALV 0.62 x 1.59 1.90 145818
#4 0.56 x 1.43 1.50 145817

FLAT PL400
MLE 4KV
#2
#4
#6
6 Low
Profile


Solid EPDM
0.54 x 1.48
0.48 x 1.26
LEAD MONEL 0.44 x 1.13
0.37 x 0.94
1.72 741052
1.28 925248
1.03 925255
1.28 1051499
#1 1.34 DIA 1.70 145805
ROUND PL205
5KV
#2 Solid PP NITR GALV 1.28 DIA 1.50 145804
#4 1.16 DIA 1.20 145803
ROUND PL300
5KV
#1
#2
#3
EPDM
Stranded/Compacted
EPDM
Or Solid
EPDM
EPDM GALV 1.39 DIA
EPDM GALV 1.31 DIA
EPDM GALV 1.18 DIA
1.75 145813
1.53 145812
1.19 145811




























Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
CABLE ACCESSORIES
CABLE CLAMPS
Weight
DESCRIPTION PART NO.
Lbs. Kgs.
CLAMP,CABLE STL 22 BLACK 0.20 0.09 067587
CLAMP, CABLE STL 32 BLACK 0.23 0.10 067595
CLAMP, CABLE SST 22 0.20 0.09 208496
CLAMP, CABLE SST 32 0.23 0.10 208504
CLAMP, CABLE MNL 22 0.20 0.09 925644
CLAMP, CABLE MNL 32 0.23 0.10 925651
SEALER,BANDING TOOL 4.50 2.04 560763
TENSIONER, BANDING TOOL 5.80 2.63 562983
SNIPS, METAL CUTTING 1-3/8 CUT 0.90 0.41 2642042
BANDING MATERIAL BY THE COIL
BANDING, CABLE STL 3/4X.020/COIL 100 45.36 127618
BANDING, CABLE SST 3/4X.020/COIL 80 36.29 127617
BANDING, CABLE MNL 3/4X.020/COIL 55 24.95 127619
SADDLES
SADDLE, CABLE #6 & #8 UNARMORED 0.05 0.02 160242
FLAT CABLE GUARDS
GUARD, CABLE 3KV GALV 8FT #1-#6 5.10 2.31 935643
GUARD, CABLE 3KV SST 8FT #1-#6 5.10 2.31 145993
CABLE REEL SUPPORT
SUPPORT CABLE REEL 430 195.05 925222
CABLE GUIDE WHEEL
WHEEL, CABLE GUIDE 36DIA #8-#1/0 RD/FT 115 52.16 925552
WHEEL, CABLE GUIDE 48DIA #8-#1/0 RD/FT 150 68.04 T777
CABLE REELS
NOM FLANGE
SIZE DIAMETER
50.0 50 IN
66.0 66 IN
78.0 78 IN
78.0 78 IN - Heavy Duty
84.0 84 IN
90.0 90 IN
DRUM TRAVERSE OVERALL Weight
DIA. WIDTH WIDTH Lbs. Kgs.
30.0 40.0 46.0 331 150.14
33.0 40.0 46.0 441 200.04
35.0 54.0 60.0 772 350.18
42.0 57.0 64.0 1037 470.38
35.0 54.0 60.0 992 449.97
42.0 57.0 64.0 1248 566.09
PART NO.
741101
741102
741103
132688
741104
741105




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009 Page-3




Wood Group ESP, Inc.
CABLE REEL CAPACITIES
ROUND CABLES (Feet per Reel)
REEL SIZE
CABLE PART CABLE
TYPE NUMBER SIZE
78
66 78 Heavy 84 90
Duty
145805 1 AWG 2500 6500 6500 7700 10000
PL205 145804 2 AWG 3000 6700 6700 8900 10300
145803 4 AWG 3100 7800 7800 10200 12600
145813 1 AWG 2400 5500 5500 6800 8800
PL300 145812 2 AWG 3943 7179 7179 9066 10953
145811 4 AWG 4888 8898 8898 11237 13577
FLAT CABLES (Feet per Reel)
PL190 741064 16 MM2 10300 18000 24000 25000 29000
145809
1 AWG
3451 6283 6283 7935 9587
PL205 145808 2 AWG 4300 9000 10200 12000 14500
145864 4 AWG 5300 11700 12100 15700 18900
PL225
155000 2 AWG
136800 4 AWG
4042 5520 7619 7619 8940
5200 7100 9800 9800 11500
145819
1 AWG
3000 6100 8500 8500 9900
PL450 145808 2 AWG 3400 6900 9600 9600 11200
145807
4 AWG
4300 8600 12000 12000 14000

























Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009






Vector

VII

Product Data Book









Wood Group ESP
5500 S.E. 59th Street
Oklahoma City, OK 73135
Tel 405-670-1431
www.woodgroup-esp.com


Wood Group-ESP 2009
2

TERM DEFINITIONS

TERM DEFINITION
C Degrees Celcius

F Degrees Farenheit

AC Alternating current

ASD Adjustable speed drive

COMM Communications

DC Direct current

DPF Displacement power factor

ESP Electric submersible pump

I/O Inputs / Outputs

IEC International electric code

IGBT Insulated gate bi-polar transistor

ISO International Organization for Standardization

LCD Liquid crystal display

MODBUS Serial Communication Protocol

PI Proportional Integral

PCP Progressing cavity pump

SCADA Supervisory Control and Data Acquisition

SPS Surface pumping systems

THD Total harmonic distortion

TVSS Transient voltage surge suppression

VAC Volts AC

VDC Volts DC

VFD Variable frequency drive

VSD Variable speed drive

VSG

Variable Sinewave Generator




Wood Group-ESP 2009
3

TABLE OF CONTENTS


TOPIC PAGE NUMBER

Term Definitions 2

Safety Notice 4

Introduction 5

Drive Description 5

Vector

VII Product Summary 6



Installation Examples 8

Catalog Number Explanation 9

Vector

VII

without VSG

Catalog Numbers - 60 Hertz 10



Vector

VII with VSG

Catalog Numbers - 60 Hertz 11



Vector

VII

without VSG

Catalog Numbers - 50 Hertz 12



Vector

VII with VSG

Catalog Numbers - 50 Hertz 13



Vector

VII Factory Installed Options 14



Manufacturer Qualifications and Certifications 15

General Specifications / Operating Conditions / Design Features 15

Operator Panel 20

Surface Pumping Systems (SPS) 29

Input Harmonic Mitigation 30

Basic 12 Pulse and 18 Pulse Drive Schematics 31

Output Harmonic Mitigation


32
Grounding and Bonding / Typical 480 VAC Drive Installation 33

Generator Requirements 34

Dimensions and Weights 36







Wood Group-ESP 2009
4





SAFETY NOTICE
Wood Group ESP, Inc. places a high priority upon personnel safety. Personnel performing
maintenance upon drives should be properly trained and follow all safety procedures to
prevent injury. Drives may cause serious injury if proper safety precautions, equipment, and
installation procedures are not used. Units should always be grounded and confirmation of
ground connection and continuity be established prior to performing any work or service. Be
sure to consult users manual before installing, energizing, or operating equipment. Installation
should always conform to local codes, regulations, or other authorities governing electrical
equipment.








































Wood Group-ESP 2009
5

INTRODUCTION

This document provides a descriptive overview of the Vector

VII

Variable Speed Drive (VSD)
available from Wood Group ESP. Information is provided on available ratings, physical size,
product features, general operation, and available options. Additional details regarding drive
set-up, operation, and troubleshooting are available in the Vector VII Variable Speed Drive
Users Manual. The descriptions and information contained in this publication are for
informational purposes only and should not be used to install, set-up, program, or operate the
Vector VII drive.

Note: This publication describes the standard Vector VII Variable Speed Drive and includes
descriptions of the most common drive options and modifications. Specific features may be
added (or disabled) from the product depending on the specific application. All specifications
and information contained in this publication are subject to change without notice.

DRIVE DESCRIPTION

The Vector VII Variable Speed Drive is designed specifically for oil-field pumping applications
including electrical submersible pumps (ESP) and surface pumping systems (SPS). Vector VII
drives are available in ratings from 104 KVA to1500 KVA. They are provided in rugged outdoor
rated enclosures designed for a wide variety of environments ranging from arctic to desert
conditions. Application specific software and a Wood Group ESP Custom Operator Control
Panel combine to optimize pump control while simplifying drive operation.
Vector VII uses the latest Insulated Gate Bipolar Transistor (IGBT) technology in combination
with surface mount printed circuit boards to create a VSD of the highest reliability, and small
physical size. Fixed voltage, three-phase AC input power is first converted to a fixed DC bus
voltage by the input rectifier section of the drive. That fixed DC bus voltage is then processed
by the inverter section to produce a sine coded variable voltage, variable frequency output to
control the speed of the motor.

For ESP applications, the Vector VII Variable Speed Drive is available with integrated VSG


Technology. With VSG Technology the drive output voltage waveform is a near perfect sine-
wave which results in improved motor performance, extended motor run life, extended motor
cable life, and increased operational efficiency in the driven equipment. Vector VII drives with
VSG (Variable Sinewave Generation) technology can successfully operate with motor cable
lengths up to 15,000 ft.

User adjustments include operating speed, acceleration and deceleration rates, motor overload
protection settings, auto restarts, time delays, and stopping methods. Control methods include
frequency control, current control, pressure control, or analog follower (Analog 1 = 0-10 VDC,
Analog 2 = 0-10 VDC or 4-20 mA) capability.












Wood Group-ESP 2009
6

VECTOR VII PRODUCT SUMMARY

Standard Drive Features:

Ratings from 104 KVA to 1500 KVA.
Specifically designed for oil field pumping applications.
NEMA 3R outdoor enclosure, rugged (10 Gauge) steel construction with compact footprint.
Enclosure base pre-drilled with slotted holes for permanent attachment to foundation.
Three point door latching mechanism.
Designed for 50C (122 F) ambient temperature, white enclosure reduces solar heating.
Input AC line circuit breaker with pad lockable flange mount external operator.
State of the art operator control panel with graphical interface.
Available with or without Variable Sinewave Generator (VSG) technology pure sine wave output.
Latest generation IGBTs (Insulated Gate Bipolar Transistors).
Microprocessor based control circuitry with non-volatile memory for all drive parameters.
Surface mount technology with protective coating on all printed circuit boards.
Input line transient voltage suppression - line to line and line to ground voltage surge protection.
Six pulse input rectification (standard) or optional multi-pulse rectification for reduced AC line harmonics.
Fused control power transformer.
Extended acceleration time - reduces electrical and mechanical stress on pump and motor.
S curve soft start / soft stop capability.
Power loss ride through capability.

Operator Panel Features:

Intuitive operator friendly menu is easy to use.
Large bright screen is easy to read in direct sunlight.
Built in real time clock provides time and date stamp for historical data and event logger.
Operator control panel monitors both drive parameters and well parameters.
Note: Wood Group ESP downhole sensor is required to monitor well parameters.
Drive and well parameters are displayed in engineering units using plain language text.
User programmable functions and operating modes.
Set point PI control closed loop programmable in engineering units.
Comprehensive run status screen shows critical drive and well data in a single location.
Time stamped event and fault log - stores last 256 drive events including faults, starts, stops, operator
changes, etc.
Historical data log - periodically samples and stores the values of 20 different drive and well parameters.
- All parameters are time (to the second) and date stamped with 35 days of data retained.
Trending screen graphically displays historical data for important drive and well parameters.
Software embedded circular recording ammeter high resolution display with 1 day or 7 day format.
Drive Status Lights
- Shows drive operating mode and are visible from a distance.
Software embedded drive lock-out and auto-restart switches.
Programmable restart capability.
USB port for data retrieval and transfer of drive information to memory stick.
- Save historical data, event log information, recording ammeter data, and drive configuration
information.
Built in Modbus communications port easy interface to customer SCADA systems.
Multiple Languages
Password protection to prevent unauthorized changes.






Wood Group-ESP 2009
7

Protective Features:

Input phase insensitive sequencing of 3 phase input power is not necessary.
DC bus reactor.
Diagnostic fault indication.
Loss of load detection.
Serial communication loss detection.
Short circuit protection.
Ground fault protection.
Loss of input phase protection.
Over voltage and under voltage protection.
Over current and under current protection.
Current limiting DC bus fuse.
Motor stall protection.
Heat sink over temperature protection.
Adjustable motor current limit.
Critical frequency avoidance three selectable frequencies with adjustable bandwidth.

Electrical Specifications:

Rated Input Voltage: 480 Volt, 3 phase, 60 Hz (+ / - 10% of rated voltage and frequency).
Consult factory for other input voltages and frequency ratings.
Efficiency: 97% or greater at full load.
Power Factor: .95 or greater Constant over operating range Not speed or load dependent
Output Voltage: 0 Volts to rated input voltage
Output Frequency: 0 Hertz to 120 Hertz.

Control Specifications:

Control Method: Sine coded output with optional VSG (Variable Sinewave Generation)
technology.
Accel / Decel: 0 Seconds to 6,000 seconds.
Drive Overload: 110% of drive rating for 60 seconds (Variable Torque).
Current Limit: Programmable current limit.

Control I/O:

Digital Inputs: 7 Programmable inputs - 24 VDC, 8 mA Sinking or Sourcing Logic.
Digital Outputs: 2 Programmable dry contacts rated 250 VAC / 30 VDC @ 1A.
1 Fault contact - Form C dry contact rated 250 VAC / 30 VDC @ 1A.
Analog Inputs: 2 Programmable inputs (10 bit).
Analog 1 = 0 to +10 VDC 20 K Ohms
Analog 2 = 0 to +10 VDC 20 K Ohms or 4 to 20 mA 250 Ohms
Analog Outputs: 2 Programmable outputs (10 bit) each = 0 to +10 VDC 2 mA.
Analog Reference: +15 VDC Source 20 mA.
Logic Reference: +24 VDC Source 8 mA.

Environmental Specifications:

Ambient Service Temperature: 0C to 50C (32F to 122F)
to -40C (-40F) with optional arctic package.
Ambient Storage Temperature: -20C to 60C (-4F to 140F)
Humidity: 0 to 100%
Altitude: Up to 1000 Meters (3300 Feet) without de-rate.
Vibration: 9.81m/s
2
(1 G) maximum at 10 to 20 Hz, 2.0 m/s
2
(0.2 G) at 20 Hz to 50 Hz.



Wood Group-ESP 2009
8

Various Installation Examples





















ESP Installation SPS Installation




ESP Installation





















ESP Installation Offshore Installation




Wood Group-ESP 2009
9

CATALOG NUMBER EXPLANATION

Position A B C D E F G H to Z
Description
Drive
Type

Rated
Amps

Rated
Volts

Rated
Hertz

Pulse

Enclosure
Type

Output
Type
Options
Example V7 - 675A - 480V - 60HZ - 6P - N3R - VSG - AP


Position

Description

Choices
A Vector 7 Drive V7
B Output Amps 180A, 304A, 414A, 515A, 675A, 910A, 1215A,
1366A, 1444A, 1821A, Other
C Input Voltage 480VAC, 380VAC, 400VAC, Other
D Input Frequency 60HZ, 50HZ
E Input Type 6P = 6 Pulse, 12P = 12 Pulse, 18P = 18 Pulse,
Other
F Enclosure Type N3R = Nema 3R, N1 = Nema 1, Other
G Output Type VSG = Sine Wave, No Entry = PWM
H Z Options See Options Table on Page 14



































Wood Group-ESP 2009
10

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives without VSG (5) - 480 VAC / 60 Hertz

Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-60HZ-6P-N3R 104 6 480 124 480 136
V7-124A-480V-60HZ-12P-N3R (3)
104 12 480 124 480 136 (1)
V7-124A-480V-60HZ-18P-N3R (3)
104 18 480 124 480 136 (2)
V7-180A-480V-60HZ-6P-N3R 150 6 480 180 480 198
V7-180A-480V-60HZ-12P-N3R (3) 150 12 480 180 480 198 (1)
V7-180A-480V-60HZ-18P-N3R (3) 150 18 480 180 480 198 (2)
V7-240A-480V-60HZ-6P-N3R 200 6
480
240 480 264
V7-240A-480V-60HZ-12P-N3R (4)
200 12
480 240
480
264 (1)
V7-240A-480V-60HZ-18P-N3R (4)
200 18
480 240
480
264 (2)
V7-304A-480V-60HZ-6P-N3R 253 6 480 304 480 334
V7-304A-480V-60HZ-12P-N3R (3) 253 12 480 304 480 334 (1)
V7-304A-480V-60HZ-18P-N3R (3) 253 18 480 304 480 334 (2)
V7-414A-480V-60HZ-6P-N3R 344 6 480 414 480 456
V7-414A-480V-60HZ-12P-N3R (3) 344 12 480 414 480 456 (1)
V7-414A-480V-60HZ-18P-N3R (3) 344 18 480 414 480 456 (2)
V7-515A-480V-60HZ-6P-N3R 428 6 480 515 480 567
V7-515A-480V-60HZ-12P-N3R (3) 428 12 480 515 480 567 (1)
V7-515A-480V-60HZ-18P-N3R (3) 428 18 480 515 480 567 (2)
V7-675A-480V-60HZ-6P-N3R 561 6 480 675 480 743
V7-675A-480V-60HZ-12P-N3R (3) 561 12 480 675 480 743 (1)
V7-675A-480V-60HZ-18P-N3R (3) 561 18 480 675 480 743 (2)
V7-910A-480V-60HZ-6P-N3R 757 6 480 910 480 1000
V7-910A-480V-60HZ-12P-N3R (3) 757 12 480 910 480 1000 (1)
V7-910A-480V-60HZ-18P-N3R (3) 757 18 480 910 480 1000 (2)
V7-1215A-480V-60HZ-6P-N3R 1010 6 480 1215 480 1340
V7-1215A-480V-60HZ-12P-N3R (3) 1010 12 480 1215 480 1340 (1)
V7-1215A-480V-60HZ-18P-N3R (3) 1010 18 480 1215 480 1340 (2)
V7-1366A-480V-60HZ-6P-N3R 1136 6 480 1366 480 1500
V7-1366A-480V-60HZ-12P-N3R (3) 1136 12 480 1366 480 1500 (1)
V7-1366A-480V-60HZ-18P-N3R (3) 1136 18 480 1366 480 1500 (2)
V7-1444A-480V-60HZ-6P-N3R 1200 6 480 1444 480 1590
V7-1444A-480V-60HZ-12P-N3R (3) 1200 12 480 1444 480 1590 (1)
V7-1444A-480V-60HZ-18P-N3R (3) 1200 18 480 1444 480 1590 (2)
V7-1821A-480V-60HZ-6P-N3R 1514 6 480 1821 480 2000
V7-1821A-480V-60HZ-12P-N3R (3) 1514 12 480 1821 480 2000 (1)
V7-1821A-480V-60HZ-18P-N3R (3) 1514 18 480 1821 480 2000 (2)

(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 480 VAC.
(5) VSG is required for ESP applications.




Wood Group-ESP 2009
11

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives with VSG - 480 VAC / 60 Hertz

Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-60HZ-6P-N3R 104 6 480 124 480 136
V7-124A-480V-60HZ-12P-N3R (3)
104 12 480 124 480 136 (1)
V7-124A-480V-60HZ-18P-N3R (3)
104 18 480 124 480 136 (2)
V7-180A-480V-60HZ-6P-N3R-VSG 150 6 480 180 480 198
V7-180A-480V-60HZ-12P-N3R-VSG (3) 150 12 480 180 480 198 (1)
V7-180A-480V-60HZ-18P-N3R-VSG (3) 150 18 480 180 480 198 (2)
V7-240A-480V-60HZ-6P-N3R-VSG 200 6
480
240 480 264
V7-240A-480V-60HZ-12P-N3R-VSG (3)
200 12
480 240
480
264 (1)
V7-240A-480V-60HZ-18P-N3R-VSG (3)
200 18
480 240
480
264 (2)
V7-304A-480V-60HZ-6P-N3R-VSG 253 6 480 304 480 334
V7-304A-480V-60HZ-12P-N3R-VSG (3) 253 12 480 304 480 334 (1)
V7-304A-480V-60HZ-18P-N3R-VSG (3) 253 18 480 304 480 334 (2)
V7-414A-480V-60HZ-6P-N3R-VSG 344 6 480 414 480 456
V7-414A-480V-60HZ-12P-N3R-VSG (3) 344 12 480 414 480 456 (1)
V7-414A-480V-60HZ-18P-N3R-VSG (3) 344 18 480 414 480 456 (2)
V7-515A-480V-60HZ-6P-N3R-VSG 428 6 480 515 480 567
V7-515A-480V-60HZ-12P-N3R-VSG (3) 428 12 480 515 480 567 (1)
V7-515A-480V-60HZ-18P-N3R-VSG (3) 428 18 480 515 480 567 (2)
V7-675A-480V-60HZ-6P-N3R-VSG 561 6 480 675 480 743
V7-675A-480V-60HZ-12P-N3R-VSG (3) 561 12 480 675 480 743 (1)
V7-675A-480V-60HZ-18P-N3R-VSG (3) 561 18 480 675 480 743 (2)
V7-910A-480V-60HZ-6P-N3R-VSG 757 6 480 910 480 1000
V7-910A-480V-60HZ-12P-N3R-VSG (3) 757 12 480 910 480 1000 (1)
V7-910A-480V-60HZ-18P-N3R-VSG (3) 757 18 480 910 480 1000 (2)
V7-1215A-480V-60HZ-6P-N3R-VSG 1010 6 480 1215 480 1340
V7-1215A-480V-60HZ-12P-N3R-VSG (3) 1010 12 480 1215 480 1340 (1)
V7-1215A-480V-60HZ-18P-N3R-VSG (3) 1010 18 480 1215 480 1340 (2)
V7-1366A-480V-60HZ-6P-N3R-VSG 1136 6 480 1366 480 1500
V7-1366A-480V-60HZ-12P-N3R-VSG (3) 1136 12 480 1366 480 1500 (1)
V7-1366A-480V-18P-N3R-VSG (3) 1136 18 480 1366 480 1500 (2)
V7-1444A-480V-60HZ-6P-N3R-VSG 1200 6 480 1444 480 1590
V7-1444A-480V-60HZ-12P-N3R-VSG (3) 1200 12 480 1444 480 1590 (1)
V7-1444A-480V-60HZ-18P-N3R-VSG (3) 1200 18 480 1444 480 1590 (2)
V7-1821A-480V-60HZ-6P-N3R-VSG 1514 6 480 1821 480 2000
V7-1821A-480V-60HZ-12P-N3R-VSG (3) 1514 12 480 1821 480 2000 (1)
V7-1821A-480V-60HZ-18P-N3R-VSG (3) 1514 18 480 1821 480 2000 (2)

(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 480 VAC.
(5) VSG is required for ESP applications.




Wood Group-ESP 2009
12

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives without VSG (5) - 380 VAC / 50 Hertz

Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-50HZ-6P-N3R 82 6 380 124 380 136
V7-124A-480V-50HZ-12P-N3R (3)
82 12 380 124 380 136 (1)
V7-124A-480V-50HZ-18P-N3R (3)
82 18 380 124 380 136 (2)
V7-180A-380V-50HZ-6P-N3R 118 6 380 180 380 198
V7-180A-380V-50HZ-12P-N3R (3)
118
12
380
180
380
198 (1)
V7-180A-380V-50HZ-18P-N3R (3)
118
18
380
180
380
198 (2)
V7-240A-380V-50HZ-6P-N3R 158 6
380
240
380
264
V7-240A-380V-50HZ-12P-N3R (3) 158
12
380 240 380 264 (1)
V7-240A-380V-50HZ-18P-N3R (3) 158
18
380 240 380 264 (2)
V7-304A-380V-50HZ-6P-N3R 200 6
380
304
380
334
V7-304A-380V-50HZ-12P-N3R (3) 200 12
380
304
380
334 (1)
V7-304A-380V-50HZ-18P-N3R (3) 200 18
380
304
380
334 (2)
V7-414A-380V-50HZ-6P-N3R 272 6
380
414
380
456
V7-414A-380V-50HZ-12P-N3R (3) 272 12
380
414
380
456 (1)
V7-414A-380V-50HZ-18P-N3R (3) 272 18
380
414
380
456 (2)
V7-515A-380V-50HZ-6P-N3R 338 6
380
515
380
567
V7-515A-380V-50HZ-12P-N3R (3) 338 12
380
515
380
567 (1)
V7-515A-380V-50HZ-18P-N3R (3) 338 18
380
515
380
567 (2)
V7-675A-380V-50HZ-6P-N3R 444 6
380
675
380
743
V7-675A-380V-50HZ-12P-N3R (3) 444 12
380
675
380
743 (1)
V7-675A-380V-50HZ-18P-N3R (3) 444 18
380
675
380
743 (2)
V7-819A-380V-50HZ-6P-N3R 539 6
380
819
380
901
V7-819A-380V-50HZ-12P-N3R (3) 539 12
380 819 380
901 (1)
V7-819A-380V-50HZ-18P-N3R (3) 539 18
380 819 380
901 (2)
V7-1093A-380V-50HZ-6P-N3R 719 6
380
1093
380
1202
V7-1093A-380V-50HZ-12P-N3R (3) 719 12
380 1093 380
1202 (1)
V7-1093A-380V-50HZ-18P-N3R (3) 719 18
380 1093 380
1202 (2)
V7-1229A-380V-50HZ-6P-N3R 809 6
380
1229
380
1352
V7-1229A-380V-50HZ-12P-N3R (3) 809 12
380 1229 380
1352 (1)
V7-1229A-380V-50HZ-18P-N3R (3) 809 18
380 1229 380
1352 (2)
V7-1300A-380V-50HZ-6P-N3R 856 6
380
1300
380
1430
V7-1300A-380V-50HZ-12P-N3R (3) 856 12
380 1300 380
1430 (1)
V7-1300A-380V-50HZ-18P-N3R (3) 856 18
380 1300 380
1430 (2)
V7-1639A-380V-50HZ-6P-N3R 1079 6
380
1639
380
1803
V7-1639A-380V-50HZ-12P-N3R (3) 1079 12
380 1639 380
1803 (1)
V7-1639A-380V-50HZ-18P-N3R (3) 1079 18
380 1639 380
1803 (2)

(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 380 VAC.
(5) VSG is required for ESP applications.




Wood Group-ESP 2009
13

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives with VSG - 380 VAC / 50 Hertz

Catalog Number
Output
KVA (4)
Input
Pulses
Output
Voltage
Output
Amperes
Input
Voltage
Input
Amperes
V7-124A-480V-50HZ-6P-N3R 82 6 380 124 380 136
V7-124A-480V-50HZ-12P-N3R (3)
82 12 380 124 380 136 (1)
V7-124A-480V-50HZ-18P-N3R (3)
82 18 380 124 380 136 (2)
V7-180A-380V-50HZ-6P-N3R-VSG 118 6 380 180
380
198
V7-180A-380V-50HZ-12P-N3R-VSG (3)
118
12
380
180
380
198 (1)
V7-180A-380V-50HZ-18P-N3R-VSG (3)
118
18
380
180
380
198 (2)
V7-240A-380V-50HZ-6P-N3R-VSG 158 6
380
240
380
264
V7-240A-380V-50HZ-12P-N3R-VSG (3) 158
12
380 240 380 264 (1)
V7-240A-380V-50HZ-18P-N3R-VSG (3) 158
18
380 240 380 264 (2)
V7-304A-380V-50HZ-6P-N3R-VSG 200 6
380
304
380
334
V7-304A-380V-50HZ-12P-N3R-VSG (3) 200 12
380
304
380
334 (1)
V7-304A-380V-50HZ-18P-N3R-VSG (3) 200 18
380
304
380
334 (2)
V7-414A-380V-50HZ-6P-N3R-VSG 272 6
380
414
380
456
V7-414A-380V-50HZ-12P-N3R-VSG (3) 272 12
380
414
380
456 (1)
V7-414A-380V-150HZ-8P-N3R-VSG (3) 272 18
380
414
380
456 (2)
V7-515A-380V-50HZ-6P-N3R-VSG 338 6
380
515
380
567
V7-515A-380V-50HZ-12P-N3R-VSG (3) 338 12
380
515
380
567 (1)
V7-515A-380V-50HZ-18P-N3R-VSG (3) 338 18
380
515
380
567 (2)
V7-675A-380V-50HZ-6P-N3R-VSG 444 6
380
675
380
743
V7-675A-380V-50HZ-12P-N3R-VSG (3) 444 12
380
675
380
743 (1)
V7-675A-380V-50HZ-18P-N3R-VSG (4) 444 18
380
675
380
743 (2)
V7-819A-380V-50HZ-6P-N3R-VSG 539 6
380
819
380
901
V7-819A-380V-50HZ-12P-N3R-VSG (3) 539 12
380 819 380
901 (1)
V7-819A-380V-50HZ-18P-N3R-VSG (3) 539 18
380 819 380
901 (2)
V7-1093A-380V-50HZ-6P-N3R-VSG 719 6
380
1093
380
1202
V7-1093A-380V-50HZ-12P-N3R-VSG(3) 719 12
380 1093 380
1202 (1)
V7-1093A-380V-50HZ-18P-N3R-VSG(3) 719 18
380 1093 380
1202 (2)
V7-1229A-380V-50HZ-6P-N3R-VSG 809 6
380
1229
380
1352
V7-1229A-380V-50HZ-12P-N3R-VSG(3) 809 12
380 1229 380
1352 (1)
V7-1229A-380V-50HZ-18P-N3R-VSG(3) 809 18
380 1229 380
1352 (2)
V7-1300A-380V-50HZ-6P-N3R-VSG 856 6
380
1300
380
1430
V7-1300A-380V-50HZ-12P-N3R-VSG(3) 856 12
380 1300 380
1430 (1)
V7-1300A-380V-50HZ-18P-N3R-VSG(3) 856 18
380 1300 380
1430 (2)
V7-1639A-380V-50HZ-6P-N3R-VSG 1079 6
380
1639
380
1803
V7-1639A-380V-50HZ-12P-N3R-VSG(3) 1079 12
380 1639 380
1803 (1)
V7-1639A-380V-50HZ-18P-N3R-VSG(3) 1079 18
380 1639 380
1803 (2)

(1) Total input amperes. Amperes per input phase are 50% of listed value.
(2) Total input amperes. Amperes per input phase are 33% of listed value.
(3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.
(4) Output KVA calculated at 380 VAC.
(5) VSG is required for ESP applications.




Wood Group-ESP 2009
14

OPTIONS TABLE

Factory Installed options include:

Code Name Ratings Description
P12 12 Pulse Field
Conversion Kit
150 -
561
Allows conversion of 6 pulse drive to a 12 pulse
drive in the field.
SH Space Heater All Prevents condensation from forming inside the
drive enclosure. Generally not suitable for
enclosure heating in cold climates.
AP Arctic Package All Provides thermostatically controlled enclosure
heaters and ventilation control for operation to
-40C (-40F).
DP Desert Package All Provides added protection to reduce solar
heating in desert applications.
AOC Analog Output
Converter
All Converts the two 0 to +/- 10V Analog Outputs
on Vector VII to 4 to 20 ma outputs.
DIC Digital Input Converter All Converts the seven 24 V DC Digital Inputs on
Vector VII to 120 VAC Digital Inputs.
TVSS Transient Voltage
Surge Suppression
All Provides additional (very robust) protection
against voltage transients and surges.
PJB Power Junction Box All For added convenience all drive power
connections (3-phase drive input and motor
output plus a ground connection) are wired to
terminal blocks in a junction box mounted on
the side of the drive enclosure.
TBX Terminal Block With
Oversized Terminals
All Provides Customer I/O Interface terminal block
with larger than standard terminals.
VCS RTU RTU for SPS Use ALL Provides Additional AI / AO and DI / DO
ES E-Stop All Provides emergency stop of drive.
DSI DownHole Sensor
Interface
All Provides interface to SmartGuard

downhole
sensor via drive Operator Control Panel.
COMM1 Wireless Router
Communications
All Provides remote user interface to drive via a
wireless computer connection.
COMM2 Satellite Interface All Provides SCADA interface to the drive via
satellite.
ETI Ethernet Interface ALL Provides Interface from drive to Ethernet
system.
SST Stainless Steel
Construction
All Provides corrosion resistance in adverse
operating conditions such as offshore platforms.
BGP Brass Gland Plate ALL For Offshore / Marine Use
CE CE Certification 105-561 Complies with European Union Certification
UL / CUL UL Certification
CUL Certification
105-561
NVSG
Complies with Underwriters Laboratory
Requirements for United States and Canada

Consult Factory for other options.







Wood Group-ESP 2009
15

MANUFACTURER QUALIFICATIONS

Wood Group ESP has been a supplier of drives for many years. Our drives are installed in a
variety of oilfield pumping applications, both onshore and offshore. These include Electric
Submersible Pumps (ESP), Surface Pumping Systems (SPS), and Progressing Cavity Pump
(PCP) applications.

Wood Group ESPs experience with a wide variety of different oilfield pumping applications has
given us the unique ability to develop a specialized drive product for the markets we serve. Our
drives include application specific software and a custom Operator Control Panel that provides a
common, easy to use operator interface to both the drives parameters and the downhole or
process sensors associated with the application.

Wood Group ESP can provide stand alone drives for indoor or outdoor environments or we can
provide complete skid mounted packages including transformers that are easy to install and
transport. We can also provide a total drive solution that includes switchgear, transformers, and
a modular E-House complete with environmental controls and fire suppression systems.

MANUFACTURER CERTIFICATIONS

Wood Group ESP is an ISO 9001 certified company. This ensures that all quality and corrective
action procedures are documented and implemented to ensure the highest level of product
quality. At Wood Group ESP our goal is complete customer satisfaction.

GENERAL SPECIFICATIONS / OPERATING CONDITIONS / DESIGN FEATURES

Input Power Requirements:

The Wood Group ESP Vector VII drive is designed to accept three phase input power within a
voltage range of 480 VAC, +/- 10%. Optionally the Vector VII drive can be configured to accept
some other standard input voltage such as 380 VAC, +/- 10% or 400 VAC +/- 10%. The input
frequency requirement of the Vector VII drive is either 50 Hz +/- 5% or 60 Hz +/- 5%. Consult
factory for all voltage requirements other than 480 VAC / 60 Hz.

The Vector VII drive has a 6 pulse input as standard and can also be supplied with an optional
12 pulse, or 18 pulse input rectifier for reduced Input AC line harmonics. These drive
configurations will require a special input phase shifting transformer (consult factory for
transformer requirements on all 12 pulse and 18 pulse applications). See harmonic mitigation
section (page 30) for details on the benefits of multi-pulse drives.

Electrical Noise Immunity:

Noise immunity is in accordance with IEC61800-3.











Wood Group-ESP 2009
16

Output Power Characteristics:

The Vector VII drive is designed to produce an adjustable voltage, adjustable frequency output
to vary the speed of an AC induction motor. Output voltage is adjustable from 0 to 100% of the
applied input voltage. Output frequency is adjustable from 0 hertz to 120 hertz.

The inverter section produces a sine coded output waveform using proven IGBT technology.
For applications requiring a sinewave output, optional Variable Sinewave Generator (VSG)
technology is available. VSG technology minimizes the effects of reflected waves caused by
long cable lengths. With VSG technology motors may be successfully operated using cable
lengths up to 15,000 feet.

Power Conditioning:

An input isolation transformer is not required for protection from normal line transients.

Overload Capability:

Vector VII drives will produce 110% of rated output current for 1 minute.

Efficiency:

Vector VII drive efficiency is 97% or higher at full load and full speed.

Enclosure Features:

NEMA 3R outdoor rated.
10 gauge welded steel construction.
Multi-stage paint process including iron phosphate wash for adhesion and white epoxy
top coat.
Lifting eyes.
Lockable door handle and flange mount external circuit breaker disconnect handle.
Door mounted Operator Control Panel - all drive adjustments can be made with the
enclosure door closed.

Hardware:

The Vector VII employs the following power components:

Diode Input 6 Pulse, 12 Pulse, and 18 Pulse configurations available.
Inverter Section with the latest generation IGBT power devices
DC bus inductor included on all ratings.
Phase to phase and phase to ground MOV protection.
Plug-in connections on printed circuit boards.
Microprocessor based inverter logic isolated from power circuits.
Operator Control Panel is common for all KVA ratings. Interface includes a large LCD
graphical display with programming keys.
Common control connections for all ratings.





Wood Group-ESP 2009
17

Control Logic:

The drive is programmable or self adjusting for operation under the following conditions:

Operate drive with motor disconnected.
Controlled shut down, with no component failure in the event of an output phase to
phase or phase to ground short circuit and annunciation of the fault condition.
Multiple programmable stop modes including - Ramp, Coast, Ramp-to-Hold, and
S-curve.
Multiple acceleration and deceleration rates.

Terminal Blocks:

Separate terminal blocks are provided for control and power wiring. Optional power junction
boxes offer additional installation convenience.

Control Inputs and Outputs:

Digital Inputs: 7 programmable inputs - 24 VDC, 8 ma sinking or sourcing logic
Digital Outputs: 2 programmable dry contacts rated 250 VAC / 30 VDC @ 1A
1 fault contact - form C dry contact rated 250 VAC / 30 VDC @ 1A
Analog Inputs: 2 programmable Inputs (10 bits)
Analog 1 = 0 to +10 VDC 20 K ohms
Analog 2 = 0 to +10 VDC 20 K ohms or 4 to 20 mA 250 ohms
Analog Outputs: 2 programmable outputs (10 bits) each = 0 to +10 VDC 2 mA
Analog Reference: +15 VDC source 20 mA
Logic Reference: +24 VDC source 8 mA




Customer Interface: Digital & Analog I/O






Wood Group-ESP 2009
18

Reference Signals:

The Vector VII drive is usually configured to be controlled locally using the door mounted Oper-
ator Control Panel. Reference signals can also come from a remote controller when the Vector
VII drive is connected to an external SCADA system. Vector VII can also be configured to follow
other reference signals including analog input signals as listed below.

1. Remote potentiometer

2. 0-10 VDC

3. 4-20 ma

Loss of Reference:

The Vector VII drive can be configured to compensate for loss of its external frequency
command. This command is considered lost if the drive reference drops to 10% of its value in
400 ms or less. Drive loss of reference can be programmed from 0 to 100% of drives speed
command setting. Factory default setting is 80% of speed command.

Power Loss Ride Through Capability:

The Vector VII drive is capable of riding through a momentary loss of input power without
shutting down.

Automatic Restart:

The Vector VII drive can be programmed to automatically restart after a drive fault. The number
of restart attempts can be programmed from 0 to 10 with a factory default setting of zero. Time
between restart attempts is programmable from .5 to 600 seconds with a factory de-fault setting
of 180 seconds.

Jump Frequencies:

Three adjustable set points that lock out continuous operation at frequencies which may pro-
duce mechanical resonance are provided. Bandwidth is selectable from 0 to 20 hertz.

Current Limit

Programmable current limit is from 0% to 180% of drive rated output current.

Acceleration / Deceleration

Accel / Decel settings provide separate adjustments to allow either setting to be adjusted from
0.0 seconds to 6000.0 seconds.

Minimum Frequency Limit / Fault

The minimum frequency limit is set as a percentage of the command / set point frequency and
may be used with PI control. If the drive senses this limit or drops below it a fault occurs and
the drive will shut down.



Wood Group-ESP 2009
19

Bus Regulation

DC Bus regulation is available to reduce the possibility of drive over-voltage trips due to
regenerative conditions. Bus voltage is monitored and an internal regulator adjusts the drives
output frequency to maintain bus voltage at a nominal (100%) level. Undervoltage trip occurs at
380 VDC and overvoltage trip occurs at 800 VDC.

Underload Detection

Enabled or disabled via programming, this feature allows the user to select the output current
level that indicates the load has been lost. A programmable timing delay can also be set.
Maximum time is 10 seconds. Factory default is Disabled and factory default time is 10
seconds.

Motor Overload Protection

Electronic motor overload protection is provided from both a current overload and motor
overheating function. Exceeding either limit results in a trip / fault condition that will de-energize
the drive. Trip time is user selectable.

Fault Memory / Event Log

Faults can be accessed via the event log screen. The event log contains the most current 256
events with each being time stamped with the month, day, year, hour and minute of occurrence.
Any parameter changes will contain previous and current settings for user reference. Data is
stored in a non-volatile memory.

Adjustments

The Operator Control Panel is used for all set-up, operation and adjustment settings. All
adjustments are stored in a nonvolatile memory. No potentiometer adjustments are used.

Communications Interface

Operator Control Panel has multiple user selectable communication port assignments for See
Options list on page 12 for other communication protocols that can be used with the drive.

Hard Start

This function allows the operator to initiate a continuous forward / reverse start of downhole
equipment. Function is designed for assistance in starting equipment that is difficult to start
because of sanded in conditions or similar circumstances. Parameters are user configurable.












Wood Group-ESP 2009
20

OPERATOR CONTROL PANEL

Interface to the Vector VII drive is provided via an Operator Control Panel with integral display.
The display is easily read in bright sunlight and has a backlit LCD. It shows drive operating
conditions, fault indications and programming information. The Operator Control Panel is stand-
ard on all drive ratings, has password protection, and provides a monitoring interface to the
optional SmartGuard

downhole sensor. Data can be retrieved from the drive using a laptop
computer or memory stick via the USB port directly below the Operator Control Panel.

Some of its features are as follows:

Intuitive Menu Select Screen. (See Figure 1)
Comprehensive Run Status Screen. (See Figure 2)
Operator Control Panel displays actual date and time. (See Figure 2)
Drive and well parameters are displayed in plain text. (See Figure 2)
All Monitors Screen gives snapshot of drive and downhole sensor status. (See Figure 3)
Software Embedded Recording Ammeter with 1 or 7 day format. (See Figure 4)
Trending Screen for various surface and downhole parameters. (See Figure 5)
Software Embedded Lock Out Switches. (See Figure 6)
Time Stamped Event Log (256 events). (See Figure 7)
SmartGuard downhole sensor screen. (See Figure 8)
History Logs (35 days of data). (See Figure 9)
Drive status lights showing the drive operating mode (See Figure 10)
Multiple Languages

A representation of the Operator Control Panel is shown below along with an explanation of the
function keys.


Operator Control Panel and USB Port Function Key Explanations



Wood Group-ESP 2009
21

Operator Control Panel Screen Examples:



Figure 1 Figure 2



Figure 3 Figure 4



Figure 5 Figure 6






Wood Group-ESP 2009
22

Operator Control Panel Screen Examples:



Figure 7 Figure 8

History Screen

This screen displays logged performance data using 20 different parameters. They are as
follows.



Figure 9


Drive Outputs SmartGuard Outputs Transformer Outputs
To Motor
Volts DC Bus Volts Intake PSI Vibration Volts
Amps Heat Sink Temp. Discharge PSI Leakage Current Amps
Hertz KW Intake Temp. UpHole DC Volts
Analog 1 PI Control Output Motor Temp.
Analog 2 Status
Digital Input





Wood Group-ESP 2009
23

Operator Control Panel Screen Examples:
Status Indicator Lights

The drive will display drive status information that can be seen from a distance.

Drive status indicators are as follows:


Green = Drive running.
Red = Drive stopped in ready state
Flashing Red = Drive stopped in fault state
Amber = Drive stopped in restart state. Drive
will automatically restart but the time to
restart is greater than 1 minute.
Flashing Amber = Drive stopped in restart or
standby state. Drive will automatically restart
in less than 1 minute. If in standby state, the
drive will restart immediately whenever the
standby switch closes.

Figure 10

Start up of the Vector VII drive can be easily accomplished using basic setup parameters such
as minimum and maximum frequency, acceleration and deceleration times, motor data,
overload and underload limits, and other parameters. An example screen is shown below.

Frequency Setup




Figure 11








Wood Group-ESP 2009
24

Operator Control Panel Screen Examples:

Alarms Setup

The Alarms Setup screen allows a logged on user to set the overload and underload limits as
well as other alarm parameters. See figures 12 and 13 below.




Figure 12 Figure 13

The Vector VII drive is capable of operating as a frequency control, a current control, a pressure
control, or it can be set to follow an Analog Signal from an external source. The following
screens show how to configure the Vector VII drive for Frequency Control or Analog Signal
Follower control.

Operating / Control Mode (Frequency and Analog Follower)















Figure 14 Figure 15









Wood Group-ESP 2009
25

Operator Control Panel Screen Examples:

Operating / Control Mode (Pressure)

An example of the pressure control mode using the internal process PI regulator is shown in
Figures 16 and 17. In this example if the pressure measured at the pump discharge falls below
the set point, the drive will speed up and try to restore the pressure (up to the maximum
frequency defined on the Frequency Setup screen Figure 17). If the pressure exceeds the set
point, the drive will slow to reduce the pressure (down to the minimum frequency defined on the
Frequency Setup screen). The drive will adjust the frequency in the opposite direction if the
intake pressure is used as a reference. Protection is provided for a loss of feedback or
reference signal. Process control can be enabled or disabled with a hardwire input.




Figure 16 Figure 17

Current Control Mode

This allows the drive to operate with a constant current reference point and would primarily be
used for gassy wells.




Figure 18


Wood Group-ESP 2009
26

Operator Control Panel Screen Examples:

Drive I/O Setup

The user can easily determine the state of I/O settings at a glance by using this screen. S1
through S7 are user digital inputs, M1-M2 along with M3-M4 are digital outputs, A1 and A2 are
analog inputs.




Figure 19


Communications (Comm) Setup

A logged on user can define SCADA Modbus address and assign how the communication ports
may be used. Comm port 2 is the default setting for external SCADA system communications.




Figure 20





Wood Group-ESP 2009
27

Operator Control Panel Screen Examples:

Miscellaneous Setup

This screen allows a logged on user to configure various parameters. For example, enable or
disable downhole sensor communications (SmartGuard), set output transformer winding ratio to
allow calculation of downhole motor voltage and current, or external fault settings status
selection.



Figure 21

Maintenance Screen

Logged on user can perform various functions such as checking or updating all drive
parameters, resetting prior parameter settings to factory defaults, upgrading firmware, or
downloading various logs and the internal digital recording ammeter data to a memory stick.
Additionally, if several drives will have the same operating parameters these settings from the
first drive can be downloaded to a memory stick and uploaded to the other drives via the USB
port. This facilitates getting all drives running.




Figure 22



Wood Group-ESP 2009
28

Operator Control Panel Screen Examples:

Last Fault Screen

User / operator can easily view current drive condition and when last fault occurred.




Figure 23

Hard Start Screen

User selectable for situations where pump may be sanded in and hard to start. This allows
submersible equipment to oscillate at pre-determined intervals and ramp up to set point speed
after equipment becomes free.




Figure 24








Wood Group-ESP 2009
29

Surface Pumping Systems (SPS)

Vector VII drives have the capability of communicating serially with the VCS RTU. This allows for
expanded I/O and use of existing VCS RTU SPS software / automation routines for control in surface
pumping applications. Drive Frequency is controlled by the fully programmable internal PID loop of the
RTU. Dedicated I/O points commonly used with SPS applications and other fully programmable I/O
points reside on the RTU. It is recommended that this RTU option be used to control startup sequencing.

Twelve digital I/O (120 VAC standard, 24 VDC optional) and 10 analog I/O (8 analog inputs (4-20 ma
standard, 0-10 VDC optional) and 2 analog outputs (0-10 VDC) are available. These are in addition to the
9 digital I/O and 4 analog I/O on the Vector VII drive (see page 7).

The following flow chart illustrates a typical SPS system start up sequence.
Also shown is the VCS RTU and typical SPS skid system.







Wood Group-ESP 2009
30

INPUT HARMONIC MITIGATION

Excessive AC Line Harmonics can cause problems in the AC power system including the
overheating of power system components such as transformers, circuit breakers, and panel
boards. It can also cause nuisance tripping of circuit breakers, and the inadvertent transfer of
electrical noise to critical loads such as communications systems, computers, and process
control equipment. Drives are a potential source of AC line harmonics and control of those
harmonics reflected back to the power distribution system may be an important consideration in
the selection of a drive. Multi-pulse drives can help you maintain

Vector VII drives may be ordered with 6 Pulse (standard), 12 Pulse, and 18 Pulse input rectifier
assemblies. The 6 pulse input rectifier assembly is generally accepted as the industry standard
for low voltage AC drives. It is very simple, relatively inexpensive, and requires no additional
(phase shifting) transformer for proper operation. When the control of Input AC line harmonics
is important, 12 Pulse and 18 Pulse input rectifier assemblies are often selected. These drive
configurations (12 Pulse and 18 Pulse) are sometimes referred to as multi-pulse drives.

The input rectifier assembly for 12 pulse and 18 pulse drives is more complex than the input
rectifier assembly for a 6 pulse drive in fact, a 12 pulse input rectifier assembly consists of two
6 pulse rectifier bridges operating in parallel and an 18 pulse input rectifier assembly consists of
three 6 pulse rectifier bridges operating in parallel. The added cost of these input rectifier
assemblies is generally not that significant in the overall cost of the drive. The major cost
differential (and it can be quite significant) between a 6 pulse drive and a 12 pulse or 18 pulse
drive is the added cost of the Phase Shift Transformer that is required for multi-pulse operation.
The multi-pulse phase shift transformers have conventional three phase inputs. The output of a
12 pulse phase shift transformer is a six wire connection and the output of an 18 pulse phase
shift transformer is a nine wire connection.

Twelve and Eighteen Pulse drives introduce lower levels of AC line harmonics into the power
system than conventional Six Pulse Drives. Typical measurements for these various different
front end configurations are shown below. These values should be used for estimating purposes
only as measured results can vary based on line impedance, other linear loads on the feeder
transformer, pre-existing harmonics due to other non-linear loads on the supply, and other
factors. In general 12 pulse drives provide substantial reduction in power line harmonics over
6 pulse units and 18 pulse drives provide IEEE-519 compliance.



Category
6-Pulse
Drive
12-Pulse
Drive
18-Pulse
Drive
Current THD 30-35% 6.5-9.5% 4.5-5%
Power Factor .92-.95 .97-.98 .98-.99
DPF .95-.97 .96-.98 .98-.99
K-Factor 3.0-5.0 2.0-3.0 1.0-2.0





Wood Group-ESP 2009
31

Multi-Pulse Examples:



12 Pulse Drive Basic Schematic







18 Pulse Drive Basic Schematic











Wood Group-ESP 2009
32

OUTPUT HARMONIC MITIGATION

Wood Group-ESP developed VSG (Variable Sinewave Generator) technology specifically for
Electric Submersible Equipment. It is a proprietary solution that provides a virtually pure
sinewave output to downhole equipment and elimination of reflected wave phenomenon (motor
spiking). Motor spiking can quickly destroy motor insulation and cause equipment failure. By
virtue of VSG performance characteristics submersible motor heating caused by output
harmonics is dramatically reduced. Typically the industry rule of thumb is that for every 10 C
heat increase over the motor design point insulation life of the equipment decreases by 50%.
Harmonics generate additional heat and mitigation of them can contribute to increased
equipment life and in some cases lower operating expenses. VSG technology is effective with
cable lengths up to 15,000 feet.




Failed motor winding Motor Spiking





Vector VII with VSG Virtually Pure Sinewave Output















Wood Group-ESP 2009
33

Grounding and Bonding

Correct system grounding and equipment bonding is required to ensure proper operation of
equipment during both normal operation and underfault conditions. Grounding and bonding
conductors provide a path to ground for lethal fault currents and voltages. Failure to correctly
ground and bond equipment can lead to equipment damage and personnel injury or death.

Grounding applies to the main service connection to ground. Service transformer wye-point and
enclosures, including the service disconnect switch, must be connected to a common ground
conductor and grounding electrodes (Refer to local electrical authority for approved grounding
electrodes and methods in your area). System ground resistance should not exceed 25 Ohms to
ground and ideally be between 1-5 Ohms to ground. Ground resistance checks should only be
made by qualified electrical inspection agencies.

Bonding applies to all other electrical equipment and raceways. A bonding conductor must be
connected from the main grounding electrodes to all enclosures, junction boxes, buildings,
electrical pipes, and the wellhead.

This equipment provides an internal ground connection for the bonding conductor. This
connector is connected to the internal ground bus of the enclosure.

A typical 3/60/480 VAC ESP installation is shown below.







Wood Group-ESP 2009
34

GENERATOR REQUIREMENTS

Generators are often used as a source of power for oil field applications. When drives are
operated from a generator, specific operational problems can occur unless the overall power
system is properly designed for the application.

Generators almost always have a higher source impedance than that of a typical electrical utility.
Therefore, the non-linear current drawn by a drive tends to distort the generator output voltage
waveform more than it would distort the voltage waveform of the electric utility. This distortion
or flat topping of the generator output voltage waveform can confuse the generators voltage
regulator and lead to a loss of voltage control and wide swings in generator output voltage.
Because of this, the control of AC line harmonics is very important in generator applications.

Whenever possible avoid situations where a generator is required to feed a load that consists
mostly of non-linear loads (such as drives). It is best if the percentage of non-linear load can be
kept to less than 20% of the total load connected to the generator. Often this is not possible.
When a generator is used in a remote location as a power provider for a single drive or a group
of drives, the percentage of non-linear load connected to the generator may approach 100%. In
these situations, the following guidelines should be followed:

1. Use a multi-pulse drive (12 pulse or 18 pulse) to significantly reduce the AC line
harmonics this is usually your best approach.

2. Oversize the alternator component of the generator to lower the relative source
impedance of the generator doubling the size of the alternator will reduce the relative
source impedance by 50%. While this may be helpful in applications where the percent-
age of non-linear load is less than 50% of the total connected load it will probably have
little or no effect in applications where non-linear loads constitute a high percentage of
the connected load.

3. Do not rely on the addition of AC line reactors between the generator and the drive to fix
the problem they simply add line impedance which often makes the problem worse.

4. Be very careful when applying harmonic filters to a generator system passive harmonic
filters generally consist of reactors and capacitors. The reactors add line impedance
which usually does not solve your problem and the capacitors can cause the power
factor to become leading under lightly loaded conditions. In general, generators do not
like a leading power factor load it confuses the generators voltage regulator and leads
to a loss of voltage control and wide swings in generator output voltage.

When Vector VII drives will be operated from a generator source it is best to contact Wood
Group ESP with the following information:

1. Generator information Manufacturer, Model #, Output Voltage, Kw, KVA, and
Impedance.

2. Load Information This information should be in the form of a power one line diagram
with complete information about all connected loads - linear and non-linear. It should
also include information about any line reactors, transformers, harmonic filters, and
power factor correction equipment included on the system.




Wood Group-ESP 2009
35

Generator supplied power systems have the same requirements for grounding and bonding as
utility supplied systems. Grounding electrodes must be installed and a common bonding
conductor must be connected to all equipment and buildings. When the generator system does
not incorporate a wye-point for connection to the system ground, then an isolation transformer is
required between the generator and input to the VSD. This provides protection from floating
voltages, and provides a wye-point for connection to the ground system.

Non compliance with the above guidelines will result in poor performance and / or equipment
failure.

A typical 3/60/480 VAC generator ESP installation is shown below.




Vented Junction Box Detail

See Application Brief 01010 and Drawing 146261 for additional references.




Wood Group-ESP 2009
36

DIMENSIONS & WEIGHTS - VECTOR VII WITHOUT VSG

REFERENCE ONLY




A and B Frames C and D Frames



HEIGHT
(INCHES / MM)
WIDTH
(INCHES / MM)
DEPTH
(INCHES / MM)

FRAME

KVA
H W W1 D D1
WEIGHT
(POUNDS / KG)
150 944 / 429
200 1025 / 465

A
253

82 / 2083

48 /
1220

36 /
915

42 /
1067

36 /
915
1100 / 499
344 1281 / 582
428 1325 / 601

B
561

88 / 2236

57 /
1448

48 /
1220

40 /
1016

36 /
915
1600 / 726
750
850

C
1000

88 / 2236

99 /
2515

72 /
1829

53 /
1347

48 /
1220

4723 / 2143

1200
1400

D
1500

88 / 2236

117 /
2972

90 /
2286

53 /
1347

48 /
1220

4800 / 2178

Note: VSG is required for all ESP applications.












Wood Group-ESP 2009
37

DIMENSIONS & WEIGHTS - VECTOR VII WITH VSG

REFERENCE ONLY





A and B Frames C and D Frames




HEIGHT
(INCHES / MM)
WIDTH
(INCHES / MM)
DEPTH
(INCHES / MM)

FRAME

KVA
H W W1 D D1
WEIGHT
(POUNDS / KG)
150 1320 / 599
200 1400 / 635

A
253

82 / 2083

48 /
1220

36 /
915

42 /
1067

36 /
915
1470 / 667
344 1781 / 808
428 1825 / 828

B
561

103 / 2616

57 /
1448

48 /
1220

40 /
1016

36 /
915
2100 / 953
750
850

C
1000

103 / 2616

99 /
2515

72 /
1829

53 /
1347

48 /
1220

5623 / 2551

1200
1400

D
1500

103 / 2616

117 /
2972

90 /
2286

53 /
1347

48 /
1220

6000 / 2722


Note: VSG is required for all ESP applications.









Wood Group-ESP 2009
38

CORPORATE OFFICE &
MANUFACTURING
WORLDWIDE SALES
& OPERATIONS
OUTSIDE U.S. SALES & SERVICE

5500 S.E. 59th St (73135)
P.O. Box 15070 (73155)
Oklahoma City, OKlahoma, USA
Tel 405-670-1431
Toll free 800-723-3771
Fax 405-670-5463

19416 Park Row, Suite 100
Houston, Texas 77084 USA
Tel 281-492-5100
Fax 281-492-8107
U.S. SALES & SERVICE
GULF COAST

Houston, Texas
Tel: 281-492-5100
Fax: 281-492-8107

Laurel, Mississippi
Tel: 601-649-2030
Toll free: 800-488-9260
Fax: 601-649-8819


MID CONTINENT

Oklahoma, City, Oklahoma*
Tel: 405-671-1431
Toll free: 800-723-3771
Fax: 405-673-5463

Purcell, Oklahoma
Tel: 405-527-1566
Toll free: 800-256-5058
Fax: 405-527-7161

PERMIAN BASIN

Artesia, New Mexico
Tel: 505-746-4614
Fax: 505-746-4519

Hobbs, New Mexico
Tel: 505-392-7999
Fax: 505-392-8190











*Manufacturing Facility in addition to
Sales & Service.



Andrews, Texas
Tel: 432-523-9701
Fax: 432-523-9700

Midland, Texas *
Tel: 432-699-7401
Toll free: 800-749-7402
Fax: 432-699-4159

Snyder, Texas
Tel: 325-573-9325
Fax: 325-573-1616

ROCKY MOUNTAIN / PACIFIC

Denver, Colorado
Tel: 303-350-2111
Toll free: 800-535-0310
Fax: 303-350-2112

Baker, Montana
Toll free: 800-535-0306
Fax: 307-234-4497

Casper, Wyoming *
Tel: 307-234-4495
Toll free: 800-535-0306
Fax: 307-234-4497
CANADA

Brooks, Alberta
Tel: 403-501-5822
Fax: 403-501-5823

Calgary, Alberta
Tel: 403-263-7166
Fax: 403-263-7211

Leduc, Alberta *
Tel: 780-955-2165
Toll free: 888-586-8909
Fax: 780-955-9487

ASIA / PACIFIC

Tanggu, China
Tel: +86-22-6691-4650

Jakarta, Indonesia
Tel: +62-21-8370-2455
Fax: +62-21-831-2456

Singapore
Tel: +65-6396-3626
Fax: +65-6396-5362

Bangkok, Thailand
Tel: +66-2722-2389
Fax: +66-2722-0775

RUSSIA / CIS

Moscow, Russia
Tel: +7-495-937-6641
Fax: +7-495-937-6642

Nizhnevartovsk, Russia *
Tel: +7-3466-416-195
Fax: +7-3466-416-295

EUROPE / AFRICA

Chad, Africa
Tel: +235-626-3279
Fax: +235-41723

Libya, North Africa
Tel: +218-21-582-218-21-484-
2093




Tunisia, Africa
Tel: +216-7169-2281
Fax: +216-7169-2281

Aberdeen, Scotland
Tel: +44-1224-85-1000
Fax: +44-1224-85-1474

LATIN AMERICA

Buenos Aires, Argentina
Tel: +54-4812-2329
Fax: +54-4812-2073

Chubut, Argentina *
Tel: +54-297-446-8254
Fax: +54-297-446-8377

Bogota, Colombia
Tel: +57-1-621-2425
Fax: +57-1-621-2264

Quito, Ecuador
Tel: 593-2-2428-211
Fax: 593-2-2428-213

El Tigre, Venezuela
Tel: +58-283-241-7151
Fax: +58-283-241-8613

Maracaibo, Venezuela *
Tel: +58-261-200-9200
Fax: +58-261-7-361993

MIDDLE EAST

Al Shark, Kuwait
Tel: 965-398-3639-2810
Fax: 965-398-3639-2811

Shati Al Qurum, Oman
Tel: 968-605501
Fax: 968-605784

Dubai, UAE *
Tel: +971-4-883-7595
Fax: +971-4-883-7579


08-15-2009
Woo d Group ESP World-Wide Operations

Saudi Arabia
Oman
UAE
Yemen

Venezuela
Colombia
Argentina
Brazil
Ecuador
Guatemala

Canada
Calgary
Nisku
Brooks
U.S.A.
Casper, WY
Denver, CO
Midland, TX
Hobbs, NM
Purcell, OK
OKC, OK

Moscow
Nizhnevartovsk
Nigeria
Egypt
Algeria
Chad
Libya

Singapore
Indonesia
Australia
Vietnam
Thailand
China
Japan

Business Regions
South America EMA North America Europe, Middle East, Africa
N No or rt th h A Am me er ri ic ca a
C Ce en nt tr ra al l A Am me er ri ic ca a
U UK K
A Af fr ri ic ca a
R Ru us ss si ia a
A As si ia a P Pa ac ci if fi ic c
M Mi id dd dl le e E Ea as st t
S So ou ut th h A Am me er ri ic ca a
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-1
TRANSFORMERS

VARIABLE SPEED DRIVE TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
67 480
480-960 DELTA
831-1663 WYE
47 x 35 x 41 119 x 89 x 104 2390 1084 136829
100 480
750-1258 DELTA
1300-2160 WYE
54 x 37 x 41 137 x 90 x 104 2530 1148 136828
130 480
750 1497 DELTA
1299 2600 WYE
56 x 46 x 44
142 x 117 x
112
2850 1293 136827
130 480
750 1550 DELTA
1299 2685 WYE
50.5 x 37 x 42 128 x 94 x 107 2850 1293 1057390
150 480
800-1559 DELTA
1386 - 2700 WYE
68 x 46 x 44
173 x 117 x
112
3740 1696 136683
200 480
1100 2200 DELTA
1905 3811 WYE
53 X 43 X 51.5
135 x 109.x
131
3530 1601 1057017
210 480
1100 2200 DELTA
1905 3810 WYE
60 x 48 x 50
152 x 122 x
127
3850

1746
136826
250 415
950-1900 DELTA
1650-3300 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 127729
250 480
1100-2200 DELTA
1905-3810 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 136682
260 480
1100 2200 DELTA
1905 3811 WYE
60 X 52 X 48
152 x 132 x
122
4220 1914 136825
350 480
1100 2200 DELTA
1905 3811 WYE
74 x 54 x 50
188 x 137 x
127
6540 2967 136824
355 480
1100 2200 DELTA
1905 3811 WYE
57.5 X 45 X
53.5
146 x 114 x
136
5350 2427 1054386
400 415
950-1900 DELTA
1650-3300 WYE
61 x 61 x 54
155 x 155 x
137
6675 3028 127961
400 480
1109-2166 DELTA
1921-3732 WYE
75 x 61 x 54
191 x 155 x
137
6675 3028 136823
400 480
1100 2200 DELTA
1905 3811 WYE
70 X 42 X 62
178 x 107 x
158
4500 2041 1057416
450 480
1100-2200 DELTA
1905-3810 WYE
78 x 46 x 58
198 x 117 x
147
8175 3708 136681
520 480
1100 2200 DELTA
1905 3811 WYE
78 x 65 x 54
198 x 165 x
137
8300 3765 136822
750 480
1300-2601 DELTA
2252-4505 WYE
82 x 67 x 60
208 x 170 x
152
9326 4230 136680
750 480
1320-2640 DELTA
2286-4572 WYE
81 x 67 x 62
206 x 170 x
157
9800 4445 136821
850 480
1400-2800 DELTA
2424-4850 WYE
82 x 68 x 62
208 x 173 x
157
11200 5080 136820
1000 480
1400-2800 DELTA
2424-4850 WYE
86 x 67 x 64
218 x 170 x
163
11500 5216 136819

Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS

SPECIALTY TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
125 6000
1100-2200 DELTA
1905-3810 WYE
56 x 45 x 46
142 x 114 x
117
3275 1486 136253
150 13800
800-1559 DELTA
1386-2700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136615
150 34500
800-1559 DELTA
13862700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136614
250 13800
1100-2200 DELTA
2200-3810 WYE
70 x 52 x 48
178 x 132 x
122
4431 2010 136675
250 34500
1100-2200 DELTA
2200-3810 WYE
78 x 52 x 50
198 x 132 x
127
4642 2106 136674
450 13800
1100-2200 DELTA
2200-3810 WYE
88 x 65 x 54
224 x 165 x
137
8450 3833 136677
450 34500
1100-2200 DELTA
2200-3810 WYE
96 x 65 x 54
244 x 165 x
137
8650 3924 136676
500 13800
1100-2200 DELTA
1905-3811 WYE
76 x 80 x 55
193 x 203 x
140
6502 2949 136198
750 13800
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
9792 4442 136679
750 34500
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
10307 4675 136678

Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-3
TRANSFORMERS

SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5 480/831 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex 37.5 2400/4160 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex
37.5 7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex 37.5 12470 *
831 3325 Y
45 x 23 x
26
114 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5 14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
19920/34500 grd
Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex 50 480/831 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex 50 2400/4160 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 12470 *
831 3325 Y
49 x 23 x
26
124 x 58 x
66
750 340
480 1920
1731- 2510 ex
50 14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
19920/34500 grd
Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS

SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.

480 1920
1731- 2510 ex
75 480/831 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731 2510 ex
75 2400/4160 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 12470 *
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex
75
19920/34500
grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex 100 480/831 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 2400/4160 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 12470 *
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
19920/34500
grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-5
TRANSFORMERS

SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167 2400/4160 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 12470
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex 167 19920/34500 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
200 7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 12470
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex
200 14400/24940 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 19920/34500 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October, 2009
TRANSFORMERS

SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5
2400/4160 Y
7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex
37.5
7200/12470 Y
14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
14400/24940 Y
19920/34500 grd Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
50
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex 75
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex 75
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex
100
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-7
TRANSFORMERS


SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
167
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
200
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1750 793

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-1
TRANSFORMERS

VARIABLE SPEED DRIVE TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
67 480
480-960 DELTA
831-1663 WYE
47 x 35 x 41 119 x 89 x 104 2390 1084 136829
100 480
750-1258 DELTA
1300-2160 WYE
54 x 37 x 41 137 x 90 x 104 2530 1148 136828
130 480
750 1497 DELTA
1299 2600 WYE
56 x 46 x 44
142 x 117 x
112
2850 1293 136827
130 480
750 1550 DELTA
1299 2685 WYE
50.5 x 37 x 42 128 x 94 x 107 2850 1293 1057390
150 480
800-1559 DELTA
1386 - 2700 WYE
68 x 46 x 44
173 x 117 x
112
3740 1696 136683
200 480
1100 2200 DELTA
1905 3811 WYE
53 X 43 X 51.5
135 x 109.x
131
3530 1601 1057017
210 480
1100 2200 DELTA
1905 3810 WYE
60 x 48 x 50
152 x 122 x
127
3850

1746
136826
250 415
950-1900 DELTA
1650-3300 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 127729
250 480
1100-2200 DELTA
1905-3810 WYE
78 x 52 x 48
198 x 132 x
122
4220 1914 136682
260 480
1100 2200 DELTA
1905 3811 WYE
60 X 52 X 48
152 x 132 x
122
4220 1914 136825
350 480
1100 2200 DELTA
1905 3811 WYE
74 x 54 x 50
188 x 137 x
127
6540 2967 136824
355 480
1100 2200 DELTA
1905 3811 WYE
57.5 X 45 X
53.5
146 x 114 x
136
5350 2427 1054386
400 415
950-1900 DELTA
1650-3300 WYE
61 x 61 x 54
155 x 155 x
137
6675 3028 127961
400 480
1109-2166 DELTA
1921-3732 WYE
75 x 61 x 54
191 x 155 x
137
6675 3028 136823
400 480
1100 2200 DELTA
1905 3811 WYE
70 X 42 X 62
178 x 107 x
158
4500 2041 1057416
450 480
1100-2200 DELTA
1905-3810 WYE
78 x 46 x 58
198 x 117 x
147
8175 3708 136681
520 480
1100 2200 DELTA
1905 3811 WYE
78 x 65 x 54
198 x 165 x
137
8300 3765 136822
750 480
1300-2601 DELTA
2252-4505 WYE
82 x 67 x 60
208 x 170 x
152
9326 4230 136680
750 480
1320-2640 DELTA
2286-4572 WYE
81 x 67 x 62
206 x 170 x
157
9800 4445 136821
850 480
1400-2800 DELTA
2424-4850 WYE
82 x 68 x 62
208 x 173 x
157
11200 5080 136820
1000 480
1400-2800 DELTA
2424-4850 WYE
86 x 67 x 64
218 x 170 x
163
11500 5216 136819

Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS

SPECIALTY TRANSFORMER 3 PHASE
DIMENSIONS
H X D X W
WEIGHT SIZE
KVA
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
125 6000
1100-2200 DELTA
1905-3810 WYE
56 x 45 x 46
142 x 114 x
117
3275 1486 136253
150 13800
800-1559 DELTA
1386-2700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136615
150 34500
800-1559 DELTA
13862700 WYE
78 x 46 x 44
198 x 117 x
112
3927 1781 136614
250 13800
1100-2200 DELTA
2200-3810 WYE
70 x 52 x 48
178 x 132 x
122
4431 2010 136675
250 34500
1100-2200 DELTA
2200-3810 WYE
78 x 52 x 50
198 x 132 x
127
4642 2106 136674
450 13800
1100-2200 DELTA
2200-3810 WYE
88 x 65 x 54
224 x 165 x
137
8450 3833 136677
450 34500
1100-2200 DELTA
2200-3810 WYE
96 x 65 x 54
244 x 165 x
137
8650 3924 136676
500 13800
1100-2200 DELTA
1905-3811 WYE
76 x 80 x 55
193 x 203 x
140
6502 2949 136198
750 13800
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
9792 4442 136679
750 34500
1100-2200 DELTA
2200-3810 WYE
90 x 67 x 60
229 x 170 x
152
10307 4675 136678

Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-3
TRANSFORMERS

SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5 480/831 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex 37.5 2400/4160 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex
37.5 7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731- 2510 ex 37.5 12470 *
831 3325 Y
45 x 23 x
26
114 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5 14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
19920/34500 grd
Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex 50 480/831 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex 50 2400/4160 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50 12470 *
831 3325 Y
49 x 23 x
26
124 x 58 x
66
750 340
480 1920
1731- 2510 ex
50 14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
19920/34500 grd
Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009
TRANSFORMERS

SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.

480 1920
1731- 2510 ex
75 480/831 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731 2510 ex
75 2400/4160 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 12470 *
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75 14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex
75
19920/34500
grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 429
480 1920
1731- 2510 ex 100 480/831 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 2400/4160 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex
100 12470 *
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100 14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
19920/34500
grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-5
TRANSFORMERS

SINGLE PHASE FACT 125
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE RANGE
Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167 2400/4160 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 12470
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167 14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex 167 19920/34500 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
200 7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 12470
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1700 771
800 3200
2884 - 4233 ex
200 14400/24940 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771
800 3200
2884 - 4233 ex 200 19920/34500 Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1700 771

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October, 2009
TRANSFORMERS

SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
480 1920
1731- 2510 ex
37.5
2400/4160 Y
7200/12470 Y
831 3325 Y
45 x 23 x
26
114 x 58 x
66
605 274
480 1920
1731 2510 ex
37.5
7200/12470 Y
14400/24940 Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
37.5
14400/24940 Y
19920/34500 grd Y
831 3325 Y
50 x 23 x
26
127 x 58 x
66
635 288
480 1920
1731- 2510 ex
50
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 23 x
26
124 x 58 x
66
710 322
480 1920
1731- 2510 ex
50
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex
50
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 23 x
26
137 x 58 x
66
750 340
480 1920
1731- 2510 ex 75
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 28 x
30
124 x 71 x
76
890 404
480 1920
1731- 2510 ex
75
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex 75
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 28 x
30
137 x 71 x
76
945 428
480 1920
1731- 2510 ex
100
2400/4160 Y
7200/12470 Y
831 3325 Y
49 x 33 x
30
124 x 84 x
76
975 442
480 1920
1731- 2510 ex 100
7200/12470 Y
14400/24940 Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469
480 1920
1731- 2510 ex
100
14400/24940 Y
19920/34500 grd Y
831 3325 Y
54 x 33 x
30
137 x 84 x
76
1035 469

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.
Wood Group ESP, Inc.
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - Oct ober , 2009 Page-7
TRANSFORMERS


SINGLE PHASE FACT 225
DIMENSIONS
H X D X W
WEIGHT KVA
**
PRIMARY
VOLTS
SECONDARY
VOLTAGE
RANGE Inches CM Lbs. Kgs.
PART
NUMBER
800 3200
2884 - 4233 ex
167
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 33 x
34
137 x 84 x
86
1645 746
800 3200
2884 - 4233 ex
167
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
167
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 33 x
34
147 x 84 x
86
1700 771
800 3200
2884 - 4233 ex
200
2400/4160 Y
7200/12470 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
7200/12470 Y
14400/24940 Y
1386 - 5543 Y
54 x 42 x
34
137 x 107 x
86
1750 793
800 3200
2884 - 4233 ex
200
14400/24940 Y
19920/34500 grd Y
1386 - 5543 Y
58 x 42 x
34
147 x 107 x
86
1750 793

*- Primaries for other delta voltages available upon request.
** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group

5 G0120 CMP 05 STG 3292 2.1 14 1 1 1 1 1 1
11 G0120 CMP 11 STG 3360 3.5 14 1 1 1 1 1 1
18 G0120 CMP 18 STG 3428 4.9 14 1 1 1 1 1 1
25 G0120 CMP 25 STG 3552 6.3 14 2 1 1 1 1 1
32 G0120 CMP 32 STG 3620 7.7 14 2 1 1 1 1 1
38 G0120 CMP 38 STG 3687 9.1 14 2 1 1 1 1 1
45 G0120 CMP 45 STG 4212 10.5 18 3 1 1 1 1 1
52 G0120 CMP 52 STG 4280 11.9 18 3 1 1 1 1 1
59 G0120 CMP 59 STG 4347 13.3 18 3 1 1 1 1 1
65 G0120 CMP 65 STG 5072 14.7 22 4 1 1 1 1 1
73 G0120 CMP 73 STG 5140 16.1 22 4 1 1 1 1 1
79 G0120 CMP 79 STG 5199 17.5 22 4 1 1 1 1 1
86 G0120 CMP 86 STG 5832 18.9 26 5 1 1 1 1 1
92 G0120 CMP 92 STG 5899 20.4 26 5 1 1 1 1 1
100 G0120 CMP 100 STG 5959 21.8 26 5 1 1 1 1 1
104 (2) 52 STG 6710 23.8 30 6 1 1 1 1 1
111 (1) 59 STG + (1) 52 STG 6777 25.2 30 6 1 1 1 1 1
118 (2) 59 STG 7309 26.6 34 7 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 7369 28 34 7 1 1 1 1 1
130 (2) 65 STG 7429 29.4 34 7 1 1 1 1 1
138 (1) 73 STG + (1) 65 STG 8062 30.8 38 8 1 1 1 1 1
146 (2) 73 STG 7130 32.2 38 8 1 1 1 1 1
152 (1) 79 STG + (1) 73 STG 8129 33.6 38 8 1 1 1 1 1
158 (2) 79 STG 8913 35 38 4 9 1 1 1 1 1
165 (1) 86 STG + (1) 79 STG 8981 36.4 38 4 9 1 1 1 1 1
172 (2) 86 STG 9049 37.8 38 4 9 1 1 1 1 1
178 (1) 92 STG + (1) 86 STG 9581 39.3 38 8 10 1 1 1 1 1
184 (2) 92 STG 9648 40.8 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.



Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-1




Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group

192 (1) 100 STG + (1) 92STG 10273 42.2 38 12 11 1 1 1 1
200 (2) 100 STG 10333 43.6 38 12 11 1 1 1 1
205 (1) 73 STG + (2) 66 STG 10419 45.5 38 12 11 1 1 1 1
212 (2) 73 STG + (1) 66 STG 11052 46.9 38 16 12 1 1 1 1
219 (3) 73 STG 11120 48.3 38 16 12 1 1 1 1
225 (1) 79 STG + (2) 73 STG 11179 49.7 38 16 12 1 1 1 1
231 (2) 79 STG + (1) 73 STG 11803 51.1 38 20 13 1 1 1 1
237 (3) 79 STG 11862 52.5 38 20 13 1 1 1 1
244 (1) 86 STG + (2) 79 STG 11930 53.9 38 20 13 1 1 1 1
251 (2) 86 STG + (1) 79 STG 12563 55.3 38 24 14 1 1 1 1
258 (3) 86 STG 12631 56.7 38 24 14 1 1 1 1
264 (1) 92 STG + (2) 86 STG 13363 58.2 38 28 15 1 1 1 1
270 (2) 92 STG + (1) 86 STG 13430 59.7 38 28 15 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.






















Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE1500) E0050
Motor
Group

7 E0050 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0050 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0050 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30 E0050 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1
37 E0050 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1
45 E0050 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1
52 E0050 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0050 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0050 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0050 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83
E0050 CMP 83 STG
5174 17.5 22 4 1 1 1 1 1
90
E0050 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98
E0050 CMP 98 STG
5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
204 (3) 68 STG 10270 43.5 38 12 11 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-3




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE2700) E0080
Motor
Group

7 E0080 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0080 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0080 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30
E0080 CMP 30 STG
3592 7.0 14 2 1 1 1 1 1
37
E0080 CMP 37 STG
3653 8.5 14 2 1 1 1 1 1
45
E0080 CMP 45 STG
4185 10.0 18 3 1 1 1 1 1
52 E0080 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0080 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0080 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0080 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83 E0080 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1
90
E0080 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98 E0080 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE5500) E0170
Motor
Group

5 E0170 CMP 05 STG 3330 2.5 14 1 1 1 1 1 1
11 E0170 CMP 11 STG 3395 4.0 14 1 1 1 1 1 1
17 E0170 CMP 17 STG 3460 5.5 14 1 1 1 1 1 1
23 E0170 CMP 23 STG 3591 7.0 14 2 1 1 1 1 1
29 E0170 CMP 29 STG 3656 8.5 14 2 1 1 1 1 1
35 E0170 CMP 35 STG 4186 10.0 18 3 1 1 1 1 1
41 E0170 CMP 41 STG 4252 11.5 18 3 1 1 1 1 1
47 E0170 CMP 47 STG 4317 13.0 18 3 1 1 1 1 1
53 E0170 CMP 53 STG 5047 14.5 22 4 1 1 1 1 1
59 E0170 CMP 59 STG 5113 16.0 22 4 1 1 1 1 1
65 E0170 CMP 65 STG 5178 17.5 22 4 1 1 1 1 1
71 E0170 CMP 71 STG 5808 19.0 26 5 1 1 1 1 1
77 E0170 CMP 77 STG 5874 20.5 26 5 1 1 1 1 1
83 E0170 CMP 83 STG 6604 22.0 30 6 1 1 1 1 1
89 E0170 CMP 89 STG 6669 23.5 30 6 1 1 1 1 1
94 (2) 47 STG 7249 26.0 34 7 1 1 1 1 1
100 (1) 53 STG + (1) 47 STG 7314 27.5 34 7 1 1 1 1 1
106 (2) 53 STG 7379 29.0 34 7 1 1 1 1 1
112 (1) 59 STG + (1) 53 STG 8010 30.5 34 8 1 1 1 1 1
118 (2) 59 STG 7076 32.0 38 8 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 8141 33.5 38 8 1 1 1 1 1
130 (2) 65 STG 8871 35.0 38 4 9 1 1 1 1 1
136 (1) 71 STG + (1) 65 STG 8936 36.5 38 4 9 1 1 1 1 1
142 (2) 71 STG 9466 38.0 38 8 10 1 1 1 1 1
148 (1) 77 STG + (1) 71 STG 9532 39.5 38 8 10 1 1 1 1 1
154 (2) 77 STG 9598 41.0 38 8 10 1 1 1 1 1
160 (1) 83 STG + (1) 77 STG 10228 42.5 38 12 11 1 1 1 1 1
166 (2) 83 STG 10293 44.0 38 12 11 1 1 1 1 1
172 (1) 89 STG + (1) 83 STG 10358 45.5 38 12 11 1 1 1 1 1
178 (2) 89 STG 10988 47.0 38 16 12 1 1 1 1 1
183 (1) 65 STG + (2) 59 STG 11104 49.5 38 16 12 1 1 1 1 1
189 (2) 65 STG + (1) 59 STG 11734 51.0 38 20 13 1 1 1 1 1
195 (3) 65 STG 11799 52.5 38 20 13 1 1 1 1 1
201 (1) 71 STG + (2) 65 STG 12429 54.0 38 24 14 1 1 1 1 1
THRUST LIMIT: 60Hz = 138 stages, 50Hz = 199 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-5





Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description

Pumps have SS & AR
Heads & Bases
Discharge
Assembly
3 Coated Steel
(TE7000) E0220
Motor
Group

154
160

(2) 77 STG HSS
(1) 83 STG + (1) 77 STG
UHSS

9598 41.0 38 8
10228 42.5 38 12
10 1
11 1
1 1 1 1
1 1 1 1
166
172
(2) 83 STG UHSS
(1) 89 STG + (1) 83 STG
UHSS
10293 44.0 38 12
10358 45.5 38 12
11 1
11 1
1 1 1 1
1 1 1 1
178
183

189
(2) 89 STG UHSS
(1) 65 STG + (2) 59 STG
UHSS
(2) 65 STG + (1) 59 STG
UHSS
10988 47.0 38 16
11104 49.5 38 16

11734 51.0 38 20
12 1
12 1
13 1
1 1 1 1
1 1 1 1
1 1 1 1
195
201

207
(3) 65 STG UHSS
(1) 71 STG + (2) 65 STG
UHSS
(2) 71 STG + (1) 65 STG
UHSS
11799 52.5 38 20
12429 54.0 38 24

12244 55.5 38 24
13 1
14 1
14 1
1 1 1 1
1 1 1 1
1 1 1 1
213
219

225
(3) 71 STG UHSS
(1) 77 STG + (2) 71 STG
UHSS
(2) 77 STG + (1) 71 STG
UHSS
12309 57.0 38 24
13040 58.5 38 28

13106 60.0 38 28
14 1
15 1
15 1
1 1 1 1
1 1 1 1
1 1 1 1
231
237

243
(3) 77 STG UHSS
(1) 83 STG + (2) 77 STG
UHSS
(2) 83 STG + (1) 77 STG
UHSS
13172 61.5 38 28
13702 63.0 38 32

13767 64.5 38 32
15 1
16 1
16 1
1 1 1 1
1 1 1 1
1 1 1 1
249
255

261
(3) 83 STG UHSS
(1) 89 STG + (2) 83 STG
UHSS
(2) 89 STG + (1) 83 STG
UHSS
14397 66.0 38 36
14462 67.5 38 36

14527 69.0 38 36
17 1
17 1
17 1
1 1 1 1
1 1 1 1
1 1 1 1
267
272
(3) 89 STG UHSS
(2) 71 STG + (2) 65 STG
UHSS
15257 70.5 38 40
15372 73.0 38 40
18 1
18 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 188 stages, 50Hz = 270 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-7




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group

2 J0240 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0240 CMP 06 STG 3542 4.0 14 1 1 1 1 1 1
9 J0240 CMP 09 STG 3634 5.4 14 1 1 1 1 1 1
12 J0240 CMP 12 STG 3791 6.8 14 2 1 1 1 1 1
15 J0240 CMP 15 STG 3883 8.2 14 2 1 1 1 1 1
19 J0240 CMP 19 STG 3994 9.5 14 2 1 1 1 1 1
22 J0240 CMP 22 STG 4551 10.9 18 3 1 1 1 1 1
25 J0240 CMP 25 STG 4643 12.3 18 3 1 1 1 1 1
29 J0240 CMP 29 STG 4754 13.7 18 3 1 1 1 1 1
32 J0240 CMP 32 STG 5514 15.0 22 4 1 1 1 1 1
35 J0240 CMP 35 STG 5603 16.4 22 4 1 1 1 1 1
39 J0240 CMP 39 STG 6279 17.8 26 5 1 1 1 1 1
42 J0240 CMP 42 STG 6371 19.2 26 5 1 1 1 1 1
45 J0240 CMP 45 STG 6463 20.5 26 5 1 1 1 1 1
48 J0240 CMP 48 STG 7220 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7436 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8012 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8123 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8218 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8878 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8967 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 9056 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9832 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9943 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 10035 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10592 38.4 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group

87 (1) 45 STG + (1) 42 STG 10684 39.7 38 8 10 1 1 1 1 1
90 (2) 45 STG 10776 41.0 38 8 10 1 1 1 1 1
93 (1) 48 STG + (1) 45 STG 11433 42.4 38 12 11 1 1 1 1 1
96 (2) 48 STG 11525 43.8 38 12 11 1 1 1 1 1
99 (1) 53 STG + (2) 32 STG 12331 46.4 38 16 12 1 1 1 1 1
102 (2) 35 STG + (1) 32 STG 12420 47.8 38 16 12 1 1 1 1
105 (3) 35STG 12259 49.2 38 16 12 1 1 1 1
109 (1) 39 STG + (2) 35 STG 12935 50.6 38 20 13 1 1 1 1
113 (2) 39 STG + (1) 35 STG 13046 52.0 38 20 13 1 1 1 1
117 (3) 39STG 13157 53.4 38 20 13 1 1 1 1
120 (1) 42 STG + (2) 39 STG 13814 54.8 38 14 14
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.

























Wood Group ESP, Inc. The ESP Specialists
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
1 1 1 1
www.woodgroup-esp.com
Page-9




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ9000) J0270
Motor
Group

2 J0270 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0270 CMP 06 STG 3543 4.0 14 1 1 1 1 1 1
9 J0270 CMP 09 STG 3636 5.4 14 1 1 1 1 1 1
12 J0270 CMP 12 STG 3793 6.8 14 2 1 1 1 1 1
15 J0270 CMP 15 STG 3886 8.2 14 2 1 1 1 1 1
19 J0270 CMP 19 STG 3998 9.5 14 2 1 1 1 1 1
22 J0270 CMP 22 STG 4555 10.9 18 3 1 1 1 1 1
25 J0270 CMP 25 STG 4648 12.3 18 3 1 1 1 1 1
29 J0270 CMP 29 STG 4760 13.7 18 3 1 1 1 1 1
32 J0270 CMP 32 STG 5520 15.0 22 4 1 1 1 1 1
35 J0270 CMP 35 STG 5610 16.4 22 4 1 1 1 1 1
39 J0270 CMP 39 STG 6287 17.8 26 5 1 1 1 1 1
42 J0270 CMP 42 STG 6379 19.2 26 5 1 1 1 1 1
45 J0270 CMP 45 STG 6472 20.5 26 5 1 1 1 1 1
48 J0270 CMP 48 STG 7230 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7446 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8023 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8135 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8230 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8890 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8730 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 8820 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9597 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9709 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 9801 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10358 38.4 38 8 10 1 1 1 1 1
87 (1) 45 STG + (1) 42 STG 10451 39.7 38 8 10 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ12000) J0360
Motor
Group

2 J0360 CMP 02 STG 3400 2.7 14 1 1 1 1 1 1
5 J0360 CMP 05 STG 3483 4.0 14 1 1 1 1 1 1
8 J0360 CMP 08 STG 3564 5.4 14 1 1 1 1 1 1
11 J0360 CMP 11 STG 3712 6.8 14 2 1 1 1 1 1
14 J0360 CMP 14 STG 3795 8.2 14 2 1 1 1 1 1
17 J0360 CMP 17 STG 3877 9.5 14 2 1 1 1 1 1
20 J0360 CMP 20 STG 4423 10.9 18 3 1 1 1 1 1
23 J0360 CMP 23 STG 4506 12.3 18 3 1 1 1 1 1
26 J0360 CMP 26 STG 4589 13.7 18 3 1 1 1 1 1
29 J0360 CMP 29 STG 5337 15.0 22 4 1 1 1 1 1
32 J0360 CMP 32 STG 5418 16.4 22 4 1 1 1 1 1
35 J0360 CMP 35 STG 6065 17.8 26 5 1 1 1 1 1
38 J0360 CMP 38 STG 6149 19.2 26 5 1 1 1 1 1
41 J0360 CMP 41 STG 6231 20.5 26 5 1 1 1 1 1
44 J0360 CMP 44 STG 6978 21.9 30 6 1 1 1 1 1
46 (2) 23 STG 7162 24.6 30 6 1 1 1 1 1
49 (1) 26 STG + (1) 23 STG 7710 26.0 34 7 1 1 1 1 1
52 (2) 26 STG 7793 27.4 34 7 1 1 1 1 1
55 (1) 29 STG + (1) 26 STG 7876 28.7 34 7 1 1 1 1 1
58 (2) 29 STG 8524 30.0 38 8 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8605 31.4 38 8 1 1 1 1 1
64 (2) 32 STG 8686 32.8 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 9333 34.2 38 4 9 1 1 1 1 1
70 (2) 35 STG 9415 35.6 38 4 9 1 1 1 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.









Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-11




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads &
Bases
Discharge
Assembly
4 Coated Steel
(TM19000) M0560
Motor
Group

8 M0560 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0560 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0560 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0560 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0560 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0560 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0560 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0560 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0560 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0560 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0560 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0560 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20 M0560 CMP A-CUT 20 STG 5464 13.6 18 3 1 1 1 1 1
21 M0560 CMP A-CUT 21 STG 6199 14.2 22 4 1 1 1 1 1
22 M0560 CMP A-CUT 22 STG 6266 14.8 22 4 1 1 1 1 1
23 M0560 CMP A-CUT 23 STG 6331 15.4 22 4 1 1 1 1 1
24 M0560 CMP A-CUT 24 STG 6398 16.0 22 4 1 1 1 1 1
25 M0560 CMP A-CUT 25 STG 6468 16.6 22 4 1 1 1 1 1
26 M0560 CMP A-CUT 26 STG 6536 17.2 22 4 1 1 1 1 1
27 M0560 CMP A-CUT 27 STG 7168 17.8 26 5 1 1 1 1 1
28 M0560 CMP A-CUT 28 STG 7232 18.4 26 5 1 1 1 1 1
29 M0560 CMP A-CUT 29 STG 7302 19.0 26 5 1 1 1 1 1
30 M0560 CMP A-CUT 30 STG 7369 19.6 26 5 1 1 1 1 1
31 M0560 CMP A-CUT 31 STG 7437 20.2 26 5 1 1 1 1 1
THRUST LIMIT: 60Hz = 21 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.









Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TM24000) M0700
Motor
Group

8 M0700 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0700 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0700 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0700 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0700 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0700 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0700 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0700 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0700 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0700 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0700 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0700 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20
21
22
23
24
25
26
27
28
29
30
31
M0700 CMP A-CUT 20 STG
M0700 CMP A-CUT 21 STG
HSS
M0700 CMP A-CUT 22 STG
HSS
M0700 CMP A-CUT 23 STG
HSS
M0700 CMP A-CUT 24 STG
HSS
M0700 CMP A-CUT 25 STG
HSS
M0700 CMP A-CUT 26 STG
HSS
M0700 CMP A-CUT 27 STG
HSS
M0700 CMP A-CUT 28 STG
HSS
M0700 CMP A-CUT 29 STG
HSS
M0700 CMP A-CUT 30 STG
HSS
M0700 CMP A-CUT 31 STG
HSS
5464 13.6 18
6199 14.2 22
6266 14.8 22
6331 15.4 22
6398 16.0 22
6468 16.6 22
6536 17.2 22
7168 17.8 26
7232 18.4 26
7302 19.0 26
7369 19.6 26
7437 20.2 26
3 1
4 1
4 1
4 1
4 1
4 1
4 1
5 1
5 1
5 1
5 1
5 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 22 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.



Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-13




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with N 950 Series SP1000 Pumps.
N 950 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TN35000) N1150
Motor
Group

1 N1150 CMP A-CUT 1 STG 3786 2.4 14 1 1 1 1 1 1
2 N1150 CMP A-CUT 2 STG 3862 3.0 14 1 1 1 1 1 1
3 N1150 CMP A-CUT 3 STG 3938 3.6 14 1 1 1 1 1 1
4 N1150 CMP A-CUT 4 STG 4014 4.2 14 1 1 1 1 1 1
5 N1150 CMP A-CUT 5 STG 4087 4.7 14 1 1 1 1 1 1
6 N1150 CMP A-CUT 6 STG 4162 5.3 14 1 1 1 1 1 1
7 N1150 CMP A-CUT 7 STG 4303 5.9 14 2 1 1 1 1 1
8 N1150 CMP A-CUT 8 STG 4379 6.5 14 2 1 1 1 1 1
9 N1150 CMP A-CUT 9 STG 4455 7.1 14 2 1 1 1 1 1
10 N1150 CMP A-CUT 10STG 4528 7.6 14 2 1 1 1 1 1
11 N1150 CMP A-CUT 11STG 4604 8.2 14 2 1 1 1 1 1
THRUST LIMIT: 60Hz = 8 stages, 50Hz = 11 stages. Selections listed are a guide only, for confirmation contact WG ESP.


























Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group

5 G0120 CMP 05 STG 3292 2.1 14 1 1 1 1 1 1
11 G0120 CMP 11 STG 3360 3.5 14 1 1 1 1 1 1
18 G0120 CMP 18 STG 3428 4.9 14 1 1 1 1 1 1
25 G0120 CMP 25 STG 3552 6.3 14 2 1 1 1 1 1
32 G0120 CMP 32 STG 3620 7.7 14 2 1 1 1 1 1
38 G0120 CMP 38 STG 3687 9.1 14 2 1 1 1 1 1
45 G0120 CMP 45 STG 4212 10.5 18 3 1 1 1 1 1
52 G0120 CMP 52 STG 4280 11.9 18 3 1 1 1 1 1
59 G0120 CMP 59 STG 4347 13.3 18 3 1 1 1 1 1
65 G0120 CMP 65 STG 5072 14.7 22 4 1 1 1 1 1
73 G0120 CMP 73 STG 5140 16.1 22 4 1 1 1 1 1
79 G0120 CMP 79 STG 5199 17.5 22 4 1 1 1 1 1
86 G0120 CMP 86 STG 5832 18.9 26 5 1 1 1 1 1
92 G0120 CMP 92 STG 5899 20.4 26 5 1 1 1 1 1
100 G0120 CMP 100 STG 5959 21.8 26 5 1 1 1 1 1
104 (2) 52 STG 6710 23.8 30 6 1 1 1 1 1
111 (1) 59 STG + (1) 52 STG 6777 25.2 30 6 1 1 1 1 1
118 (2) 59 STG 7309 26.6 34 7 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 7369 28 34 7 1 1 1 1 1
130 (2) 65 STG 7429 29.4 34 7 1 1 1 1 1
138 (1) 73 STG + (1) 65 STG 8062 30.8 38 8 1 1 1 1 1
146 (2) 73 STG 7130 32.2 38 8 1 1 1 1 1
152 (1) 79 STG + (1) 73 STG 8129 33.6 38 8 1 1 1 1 1
158 (2) 79 STG 8913 35 38 4 9 1 1 1 1 1
165 (1) 86 STG + (1) 79 STG 8981 36.4 38 4 9 1 1 1 1 1
172 (2) 86 STG 9049 37.8 38 4 9 1 1 1 1 1
178 (1) 92 STG + (1) 86 STG 9581 39.3 38 8 10 1 1 1 1 1
184 (2) 92 STG 9648 40.8 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.



Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-1




Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.
G 513 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TG4000) G0120
Motor
Group

192 (1) 100 STG + (1) 92STG 10273 42.2 38 12 11 1 1 1 1
200 (2) 100 STG 10333 43.6 38 12 11 1 1 1 1
205 (1) 73 STG + (2) 66 STG 10419 45.5 38 12 11 1 1 1 1
212 (2) 73 STG + (1) 66 STG 11052 46.9 38 16 12 1 1 1 1
219 (3) 73 STG 11120 48.3 38 16 12 1 1 1 1
225 (1) 79 STG + (2) 73 STG 11179 49.7 38 16 12 1 1 1 1
231 (2) 79 STG + (1) 73 STG 11803 51.1 38 20 13 1 1 1 1
237 (3) 79 STG 11862 52.5 38 20 13 1 1 1 1
244 (1) 86 STG + (2) 79 STG 11930 53.9 38 20 13 1 1 1 1
251 (2) 86 STG + (1) 79 STG 12563 55.3 38 24 14 1 1 1 1
258 (3) 86 STG 12631 56.7 38 24 14 1 1 1 1
264 (1) 92 STG + (2) 86 STG 13363 58.2 38 28 15 1 1 1 1
270 (2) 92 STG + (1) 86 STG 13430 59.7 38 28 15 1 1 1 1
THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable).
Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.






















Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE1500) E0050
Motor
Group

7 E0050 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0050 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0050 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30 E0050 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1
37 E0050 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1
45 E0050 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1
52 E0050 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0050 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0050 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0050 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83
E0050 CMP 83 STG
5174 17.5 22 4 1 1 1 1 1
90
E0050 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98
E0050 CMP 98 STG
5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
204 (3) 68 STG 10270 43.5 38 12 11 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-3




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE2700) E0080
Motor
Group

7 E0080 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1
14
E0080 CMP 14 STG
3393 4.0 14 1 1 1 1 1 1
22
E0080 CMP 22 STG
3460 5.5 14 1 1 1 1 1 1
30
E0080 CMP 30 STG
3592 7.0 14 2 1 1 1 1 1
37
E0080 CMP 37 STG
3653 8.5 14 2 1 1 1 1 1
45
E0080 CMP 45 STG
4185 10.0 18 3 1 1 1 1 1
52 E0080 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1
60 E0080 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1
68 E0080 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1
75 E0080 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1
83 E0080 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1
90
E0080 CMP 90 STG
5800 19.0 26 5 1 1 1 1 1
98 E0080 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1
104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1
112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1
120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1
128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1
136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1
143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1
150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1
158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1
166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1
173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1
180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1
188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1
196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
3 Coated Steel
(TE5500) E0170
Motor
Group

5 E0170 CMP 05 STG 3330 2.5 14 1 1 1 1 1 1
11 E0170 CMP 11 STG 3395 4.0 14 1 1 1 1 1 1
17 E0170 CMP 17 STG 3460 5.5 14 1 1 1 1 1 1
23 E0170 CMP 23 STG 3591 7.0 14 2 1 1 1 1 1
29 E0170 CMP 29 STG 3656 8.5 14 2 1 1 1 1 1
35 E0170 CMP 35 STG 4186 10.0 18 3 1 1 1 1 1
41 E0170 CMP 41 STG 4252 11.5 18 3 1 1 1 1 1
47 E0170 CMP 47 STG 4317 13.0 18 3 1 1 1 1 1
53 E0170 CMP 53 STG 5047 14.5 22 4 1 1 1 1 1
59 E0170 CMP 59 STG 5113 16.0 22 4 1 1 1 1 1
65 E0170 CMP 65 STG 5178 17.5 22 4 1 1 1 1 1
71 E0170 CMP 71 STG 5808 19.0 26 5 1 1 1 1 1
77 E0170 CMP 77 STG 5874 20.5 26 5 1 1 1 1 1
83 E0170 CMP 83 STG 6604 22.0 30 6 1 1 1 1 1
89 E0170 CMP 89 STG 6669 23.5 30 6 1 1 1 1 1
94 (2) 47 STG 7249 26.0 34 7 1 1 1 1 1
100 (1) 53 STG + (1) 47 STG 7314 27.5 34 7 1 1 1 1 1
106 (2) 53 STG 7379 29.0 34 7 1 1 1 1 1
112 (1) 59 STG + (1) 53 STG 8010 30.5 34 8 1 1 1 1 1
118 (2) 59 STG 7076 32.0 38 8 1 1 1 1 1
124 (1) 65 STG + (1) 59 STG 8141 33.5 38 8 1 1 1 1 1
130 (2) 65 STG 8871 35.0 38 4 9 1 1 1 1 1
136 (1) 71 STG + (1) 65 STG 8936 36.5 38 4 9 1 1 1 1 1
142 (2) 71 STG 9466 38.0 38 8 10 1 1 1 1 1
148 (1) 77 STG + (1) 71 STG 9532 39.5 38 8 10 1 1 1 1 1
154 (2) 77 STG 9598 41.0 38 8 10 1 1 1 1 1
160 (1) 83 STG + (1) 77 STG 10228 42.5 38 12 11 1 1 1 1 1
166 (2) 83 STG 10293 44.0 38 12 11 1 1 1 1 1
172 (1) 89 STG + (1) 83 STG 10358 45.5 38 12 11 1 1 1 1 1
178 (2) 89 STG 10988 47.0 38 16 12 1 1 1 1 1
183 (1) 65 STG + (2) 59 STG 11104 49.5 38 16 12 1 1 1 1 1
189 (2) 65 STG + (1) 59 STG 11734 51.0 38 20 13 1 1 1 1 1
195 (3) 65 STG 11799 52.5 38 20 13 1 1 1 1 1
201 (1) 71 STG + (2) 65 STG 12429 54.0 38 24 14 1 1 1 1 1
THRUST LIMIT: 60Hz = 138 stages, 50Hz = 199 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-5





Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.
E 562 SERIES SP1000





ESP Pump Description

Pumps have SS & AR
Heads & Bases
Discharge
Assembly
3 Coated Steel
(TE7000) E0220
Motor
Group

154
160

(2) 77 STG HSS
(1) 83 STG + (1) 77 STG
UHSS

9598 41.0 38 8
10228 42.5 38 12
10 1
11 1
1 1 1 1
1 1 1 1
166
172
(2) 83 STG UHSS
(1) 89 STG + (1) 83 STG
UHSS
10293 44.0 38 12
10358 45.5 38 12
11 1
11 1
1 1 1 1
1 1 1 1
178
183

189
(2) 89 STG UHSS
(1) 65 STG + (2) 59 STG
UHSS
(2) 65 STG + (1) 59 STG
UHSS
10988 47.0 38 16
11104 49.5 38 16

11734 51.0 38 20
12 1
12 1
13 1
1 1 1 1
1 1 1 1
1 1 1 1
195
201

207
(3) 65 STG UHSS
(1) 71 STG + (2) 65 STG
UHSS
(2) 71 STG + (1) 65 STG
UHSS
11799 52.5 38 20
12429 54.0 38 24

12244 55.5 38 24
13 1
14 1
14 1
1 1 1 1
1 1 1 1
1 1 1 1
213
219

225
(3) 71 STG UHSS
(1) 77 STG + (2) 71 STG
UHSS
(2) 77 STG + (1) 71 STG
UHSS
12309 57.0 38 24
13040 58.5 38 28

13106 60.0 38 28
14 1
15 1
15 1
1 1 1 1
1 1 1 1
1 1 1 1
231
237

243
(3) 77 STG UHSS
(1) 83 STG + (2) 77 STG
UHSS
(2) 83 STG + (1) 77 STG
UHSS
13172 61.5 38 28
13702 63.0 38 32

13767 64.5 38 32
15 1
16 1
16 1
1 1 1 1
1 1 1 1
1 1 1 1
249
255

261
(3) 83 STG UHSS
(1) 89 STG + (2) 83 STG
UHSS
(2) 89 STG + (1) 83 STG
UHSS
14397 66.0 38 36
14462 67.5 38 36

14527 69.0 38 36
17 1
17 1
17 1
1 1 1 1
1 1 1 1
1 1 1 1
267
272
(3) 89 STG UHSS
(2) 71 STG + (2) 65 STG
UHSS
15257 70.5 38 40
15372 73.0 38 40
18 1
18 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 188 stages, 50Hz = 270 stages (for Higher Pressures, Floater Pumps may be suitable).
Selections listed are a guide only, for confirmation contact WG ESP.


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-7




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group

2 J0240 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0240 CMP 06 STG 3542 4.0 14 1 1 1 1 1 1
9 J0240 CMP 09 STG 3634 5.4 14 1 1 1 1 1 1
12 J0240 CMP 12 STG 3791 6.8 14 2 1 1 1 1 1
15 J0240 CMP 15 STG 3883 8.2 14 2 1 1 1 1 1
19 J0240 CMP 19 STG 3994 9.5 14 2 1 1 1 1 1
22 J0240 CMP 22 STG 4551 10.9 18 3 1 1 1 1 1
25 J0240 CMP 25 STG 4643 12.3 18 3 1 1 1 1 1
29 J0240 CMP 29 STG 4754 13.7 18 3 1 1 1 1 1
32 J0240 CMP 32 STG 5514 15.0 22 4 1 1 1 1 1
35 J0240 CMP 35 STG 5603 16.4 22 4 1 1 1 1 1
39 J0240 CMP 39 STG 6279 17.8 26 5 1 1 1 1 1
42 J0240 CMP 42 STG 6371 19.2 26 5 1 1 1 1 1
45 J0240 CMP 45 STG 6463 20.5 26 5 1 1 1 1 1
48 J0240 CMP 48 STG 7220 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7436 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8012 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8123 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8218 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8878 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8967 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 9056 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9832 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9943 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 10035 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10592 38.4 38 8 10 1 1 1 1 1
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ7500) J0240
Motor
Group

87 (1) 45 STG + (1) 42 STG 10684 39.7 38 8 10 1 1 1 1 1
90 (2) 45 STG 10776 41.0 38 8 10 1 1 1 1 1
93 (1) 48 STG + (1) 45 STG 11433 42.4 38 12 11 1 1 1 1 1
96 (2) 48 STG 11525 43.8 38 12 11 1 1 1 1 1
99 (1) 53 STG + (2) 32 STG 12331 46.4 38 16 12 1 1 1 1 1
102 (2) 35 STG + (1) 32 STG 12420 47.8 38 16 12 1 1 1 1
105 (3) 35STG 12259 49.2 38 16 12 1 1 1 1
109 (1) 39 STG + (2) 35 STG 12935 50.6 38 20 13 1 1 1 1
113 (2) 39 STG + (1) 35 STG 13046 52.0 38 20 13 1 1 1 1
117 (3) 39STG 13157 53.4 38 20 13 1 1 1 1
120 (1) 42 STG + (2) 39 STG 13814 54.8 38 14 14
THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump.
Selections listed are a guide only, for confirmation contact WG ESP.

























Wood Group ESP, Inc. The ESP Specialists
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009
1 1 1 1
www.woodgroup-esp.com
Page-9




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ9000) J0270
Motor
Group

2 J0270 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1
6 J0270 CMP 06 STG 3543 4.0 14 1 1 1 1 1 1
9 J0270 CMP 09 STG 3636 5.4 14 1 1 1 1 1 1
12 J0270 CMP 12 STG 3793 6.8 14 2 1 1 1 1 1
15 J0270 CMP 15 STG 3886 8.2 14 2 1 1 1 1 1
19 J0270 CMP 19 STG 3998 9.5 14 2 1 1 1 1 1
22 J0270 CMP 22 STG 4555 10.9 18 3 1 1 1 1 1
25 J0270 CMP 25 STG 4648 12.3 18 3 1 1 1 1 1
29 J0270 CMP 29 STG 4760 13.7 18 3 1 1 1 1 1
32 J0270 CMP 32 STG 5520 15.0 22 4 1 1 1 1 1
35 J0270 CMP 35 STG 5610 16.4 22 4 1 1 1 1 1
39 J0270 CMP 39 STG 6287 17.8 26 5 1 1 1 1 1
42 J0270 CMP 42 STG 6379 19.2 26 5 1 1 1 1 1
45 J0270 CMP 45 STG 6472 20.5 26 5 1 1 1 1 1
48 J0270 CMP 48 STG 7230 21.9 30 6 1 1 1 1 1
50 (2) 25 STG 7446 24.6 30 6 1 1 1 1 1
54 (1) 29 STG + (1) 25 STG 8023 26.0 34 7 1 1 1 1 1
58 (2) 29 STG 8135 27.4 34 7 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8230 28.7 34 7 1 1 1 1 1
64 (2) 32 STG 8890 30.0 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 8730 31.4 38 8 1 1 1 1 1
70 (2) 35 STG 8820 32.8 38 8 1 1 1 1 1
74 (1) 39 STG + (1) 35 STG 9597 34.2 38 4 9 1 1 1 1 1
78 (2) 39 STG 9709 35.6 38 4 9 1 1 1 1 1
81 (1) 42 STG + (1) 39 STG 9801 37.0 38 4 9 1 1 1 1 1
84 (2) 42 STG 10358 38.4 38 8 10 1 1 1 1 1
87 (1) 45 STG + (1) 42 STG 10451 39.7 38 8 10 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.





Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.
J 700 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads
& Bases
Discharge
Assembly
4 Coated Steel
(TJ12000) J0360
Motor
Group

2 J0360 CMP 02 STG 3400 2.7 14 1 1 1 1 1 1
5 J0360 CMP 05 STG 3483 4.0 14 1 1 1 1 1 1
8 J0360 CMP 08 STG 3564 5.4 14 1 1 1 1 1 1
11 J0360 CMP 11 STG 3712 6.8 14 2 1 1 1 1 1
14 J0360 CMP 14 STG 3795 8.2 14 2 1 1 1 1 1
17 J0360 CMP 17 STG 3877 9.5 14 2 1 1 1 1 1
20 J0360 CMP 20 STG 4423 10.9 18 3 1 1 1 1 1
23 J0360 CMP 23 STG 4506 12.3 18 3 1 1 1 1 1
26 J0360 CMP 26 STG 4589 13.7 18 3 1 1 1 1 1
29 J0360 CMP 29 STG 5337 15.0 22 4 1 1 1 1 1
32 J0360 CMP 32 STG 5418 16.4 22 4 1 1 1 1 1
35 J0360 CMP 35 STG 6065 17.8 26 5 1 1 1 1 1
38 J0360 CMP 38 STG 6149 19.2 26 5 1 1 1 1 1
41 J0360 CMP 41 STG 6231 20.5 26 5 1 1 1 1 1
44 J0360 CMP 44 STG 6978 21.9 30 6 1 1 1 1 1
46 (2) 23 STG 7162 24.6 30 6 1 1 1 1 1
49 (1) 26 STG + (1) 23 STG 7710 26.0 34 7 1 1 1 1 1
52 (2) 26 STG 7793 27.4 34 7 1 1 1 1 1
55 (1) 29 STG + (1) 26 STG 7876 28.7 34 7 1 1 1 1 1
58 (2) 29 STG 8524 30.0 38 8 1 1 1 1 1
61 (1) 32 STG + (1) 29 STG 8605 31.4 38 8 1 1 1 1 1
64 (2) 32 STG 8686 32.8 38 8 1 1 1 1 1
67 (1) 35 STG + (1) 32 STG 9333 34.2 38 4 9 1 1 1 1 1
70 (2) 35 STG 9415 35.6 38 4 9 1 1 1 1 1
THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.









Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-11




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000





ESP Pump Description

Pumps have SS & AR Heads &
Bases
Discharge
Assembly
4 Coated Steel
(TM19000) M0560
Motor
Group

8 M0560 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0560 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0560 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0560 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0560 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0560 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0560 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0560 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0560 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0560 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0560 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0560 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20 M0560 CMP A-CUT 20 STG 5464 13.6 18 3 1 1 1 1 1
21 M0560 CMP A-CUT 21 STG 6199 14.2 22 4 1 1 1 1 1
22 M0560 CMP A-CUT 22 STG 6266 14.8 22 4 1 1 1 1 1
23 M0560 CMP A-CUT 23 STG 6331 15.4 22 4 1 1 1 1 1
24 M0560 CMP A-CUT 24 STG 6398 16.0 22 4 1 1 1 1 1
25 M0560 CMP A-CUT 25 STG 6468 16.6 22 4 1 1 1 1 1
26 M0560 CMP A-CUT 26 STG 6536 17.2 22 4 1 1 1 1 1
27 M0560 CMP A-CUT 27 STG 7168 17.8 26 5 1 1 1 1 1
28 M0560 CMP A-CUT 28 STG 7232 18.4 26 5 1 1 1 1 1
29 M0560 CMP A-CUT 29 STG 7302 19.0 26 5 1 1 1 1 1
30 M0560 CMP A-CUT 30 STG 7369 19.6 26 5 1 1 1 1 1
31 M0560 CMP A-CUT 31 STG 7437 20.2 26 5 1 1 1 1 1
THRUST LIMIT: 60Hz = 21 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.









Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-12 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.
M 950 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TM24000) M0700
Motor
Group

8 M0700 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1
9 M0700 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1
10 M0700 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1
11 M0700 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1
12 M0700 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1
13 M0700 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1
14 M0700 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1
15 M0700 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1
16 M0700 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1
17 M0700 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1
18 M0700 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1
19 M0700 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1
20
21
22
23
24
25
26
27
28
29
30
31
M0700 CMP A-CUT 20 STG
M0700 CMP A-CUT 21 STG
HSS
M0700 CMP A-CUT 22 STG
HSS
M0700 CMP A-CUT 23 STG
HSS
M0700 CMP A-CUT 24 STG
HSS
M0700 CMP A-CUT 25 STG
HSS
M0700 CMP A-CUT 26 STG
HSS
M0700 CMP A-CUT 27 STG
HSS
M0700 CMP A-CUT 28 STG
HSS
M0700 CMP A-CUT 29 STG
HSS
M0700 CMP A-CUT 30 STG
HSS
M0700 CMP A-CUT 31 STG
HSS
5464 13.6 18
6199 14.2 22
6266 14.8 22
6331 15.4 22
6398 16.0 22
6468 16.6 22
6536 17.2 22
7168 17.8 26
7232 18.4 26
7302 19.0 26
7369 19.6 26
7437 20.2 26
3 1
4 1
4 1
4 1
4 1
4 1
4 1
5 1
5 1
5 1
5 1
5 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
THRUST LIMIT: 60Hz = 22 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.



Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-13




Wood Group ESP, Inc.
SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with N 950 Series SP1000 Pumps.
N 950 SERIES SP1000





ESP Pump Description
Pumps have SS & AR Heads &
Bases
Discharge
Assembly
6 Coated Steel
(TN35000) N1150
Motor
Group

1 N1150 CMP A-CUT 1 STG 3786 2.4 14 1 1 1 1 1 1
2 N1150 CMP A-CUT 2 STG 3862 3.0 14 1 1 1 1 1 1
3 N1150 CMP A-CUT 3 STG 3938 3.6 14 1 1 1 1 1 1
4 N1150 CMP A-CUT 4 STG 4014 4.2 14 1 1 1 1 1 1
5 N1150 CMP A-CUT 5 STG 4087 4.7 14 1 1 1 1 1 1
6 N1150 CMP A-CUT 6 STG 4162 5.3 14 1 1 1 1 1 1
7 N1150 CMP A-CUT 7 STG 4303 5.9 14 2 1 1 1 1 1
8 N1150 CMP A-CUT 8 STG 4379 6.5 14 2 1 1 1 1 1
9 N1150 CMP A-CUT 9 STG 4455 7.1 14 2 1 1 1 1 1
10 N1150 CMP A-CUT 10STG 4528 7.6 14 2 1 1 1 1 1
11 N1150 CMP A-CUT 11STG 4604 8.2 14 2 1 1 1 1 1
THRUST LIMIT: 60Hz = 8 stages, 50Hz = 11 stages. Selections listed are a guide only, for confirmation contact WG ESP.


























Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-14 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009






Wood Group ESP, Inc.

















WELLHEAD EQUIPMENT

WELLHEADS HHS - COMPLETE UNIT
PART NUMBER
CSG O.D.
TBG

4 1/2

5 1/2

7


8 5/8



9 5/8



10 3/4


13 3/8
EUE
#1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741261
2 7/8 741263
2 3/8
2 7/8 741234
3 1/2 741241 741243
2 3/8
2 7/8
3 1/2
4 1/2
2 3/8
2 7/8
3 1/2 741259
4 1/2 741482 741260
5 1/2 741251
2 7/8
4 1/2 741255
5 1/2 741253
7 741254
6 741262
7
6 5/8 741285
#2 RND #2 FLAT #4 RND
741205 741202
741211 741208
741217 741214
741223 741220
741229 741226
741233 741237 741232
741240 741242 741239
741244 741245
721247
741248
741257

741249 741529
741250
741455

741252




741283
#4 FLAT #6 RND #6 FLAT #8 RND
741204 741201 741203 741200
741210 741207 741209 741206
741216 741213 741215 741212
741222 741219 741221 741218
741228 741225 741227 741224
741236 741231 741235 741230
741284 741238
741256 741246
741458
741798


Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 1





Wood Group ESP, Inc.
WELLHEAD EQUIPMENT

WELLHEADS HHS - TOP PLATE
PART NUMBER
CSG O.D.
TBG

4 1/2

5 1/2

7

8 5/8


9 5/8

10 3/4

13 3/8
PLATE
EUE
#1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741377
2 7/8 741410
2 3/8
2 7/8 741410
3 1/2 741410
2 7/8
4 1/2
2 3/8
2 7/8
3 1/2 741434
4 1/2 741437
4 1/2 741419
6 741467
6 5/8 741467
7
#2 RND #2 FLAT #4 RND
741377 741368
741395 741386
741377 741368
741395 741386
741377 741368
741422 741395 741386
741410



741440
741444




741453
#4 FLAT #6 RND #6 FLAT #8 RND
741374 741365 741371 741362
741392 741383 741389 741380
741374 741365 741371 741362
741392 741383 741389 741380
741374 741365 741371 741362
741392 741383 741389 741380
741472
741416

741474
WELLHEADS HHS - BOTTOM
PART NUMBER
CSG O.D.
TBG

4 1/2

5 1/2

7

8 5/8

9 5/8



10 3/4

13 3/8
EUE
#1 RND #1 FLAT
2 3/8
2 7/8
2 3/8 741375
2 7/8 741408
2 3/8
2 7/8 741423 741408
3 1/2 741405 741408
2 7/8
4 1/2
2 3/8
2 7/8
3 1/2 741448 741432
4 1/2 741435
4 1/2 741417
6 741465
6 5/8 741451
7
#2 RND #2 FLAT #4 RND
741375 741366
741393 741384
741375 741366
741393 741384
741375 741366
741420 741393 741384
741402 741408 741399

741426

741438
741442 741449




741465
#4 FLAT #6 RND #6 FLAT #8 RND
741372 741363 741369 741360
741390 741381 741387 741378
741372 741363 741369 741360
741390 741381 741387 741378
741372 741363 741369 741360
741390 741381 741387 741378
741470 741396
741414
741459









Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-2 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
WELLHEAD EQUIPMENT

WELLHEADS HHS - PACKOFF RUBBERS
PART NUMBER
CSG O.D.
TBG

4 1/2

5 1/2

7

8 5/8


9 5/8

10 3/4


13 3/8
GLAND
EUE #1 RND #1 FLAT

2 3/8
2 7/8
2 3/8 741359
2 7/8 741412
2 3/8
2 7/8 741424 741412
3 1/2 741266 741412
2 7/8
4 1/2
2 3/8
2 7/8
3 1/2 741433
4 1/2 741436
4 1/2 741418
7 741800
6 741466
6 5/8 741452
7
#2 RND #2 FLAT #4 RND
741376 741367
741394 741385
741376 741367
741394 741385
741376 741367
741421 741394 741385
741409



741439
741443





741466
#4 FLAT #6 RND #6 FLAT #8 RND
741373 741364 741361
741391 741382 741388 741379
741373 741364 741361
741391 741382 741388 741379
741373 741364 741361
741391 741382 741388 741379
741471
741415

741473
WELLHEAD HHS - BODY - SLIPS - PACKING
CSG
O.D
BODY
4 1/2
5 1/2
7
8 5/8
9 5/8
10 3/4
13 3/8

PART
NUMBER 2 3/8 2 7/8

741350 741300 741301
741351 741300 741301
741352 741300 741301
741353 741430
741354 741304 741441
741355
741469
SLIPS PART NUMBER

3 1/2 4 1/2 5 1/2 6



741302 741429

741308 741303
741305
PACKING
GLAND
6 5/8 7 PART
NUMBER
741340
741340
741340
741342
741341
741341
741450 741464 741468

HHS SPECIFICATIONS

TYPE

HHS
HHS
HHS
HHS
HHS
HHS
HHS
HHS
HHS

CASING SIZE TUBING SIZE
O.D. (Inches) O.D. (Inches)

4 1/2, 5 1/2, 7 2 3/8
4 1/2, 5 1/2, 7 2 7/8
7 3 1/2
8 5/8 2 3/8, 3 1/2
8 5/8 4 1/2
8 5/8 5 1/2
9 5/8, 10 3/4 2 3/8, 3 1/2
9 5/8, 10 3/4 4 1/2
9 5/8, 10 3/4 5 1/2
RECOMMENDED
MAX LOAD
Lbs Kgs
80,000 36,000
80,000 36,000
80,000 36,000
100,000 45,000
100,000 45,000
100,000 45,000
100,000 45,000
100,000 45,000
100,000 45,000
MAXIMUM
SETTING DEPTH WEIGHT
(Safety Factor = 2.0)
Ft. M. Lbs Kgs
10,000 3,048 144 66
7,100 2,165 144 66
4,900 1,495 148 68
4,900 1,495 186 85
3,200 975 186 85
2,600 790 186 85
4,900 1,495 226 103
3,200 975 226 103
2,600 790 226 103




Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 3





Wood Group ESP, Inc.
Bolt
On
Head
Couplings between Units
Couplings are shipped at the top of each unit except for the coupling adapter at the bottom of the seal and the
pump to intake (or GS) that must be ordered separately. All coupling splines are SAE 6 tooth, unless noted as
INV (Involute).
Coupling TA/TR3 TD/TR387/TR4 TG/TR5 TE/TR5/E56 TH/TR5 TJ/TR7 TM/TR7 TN
919415
Pump



Pump



Intake or
Gas
Separator



Seal





Pump
To
Pump









Pump
To
Intake
or GS
(3/8 )

914341
(5/8)

934182
(11/16)
Cprsn

120555
(5/8)
120556
(11/16)

919605
(3/8 to
11/16)
912022
(5/8 to
11/16)
934182
(11/16)
1008556 (1/2)
926477 (5/8)
934182 (11/16)
934026 (7/8)
Cprsn
120554 (1/2)
120555 (5/8)
120556 (11/16)
120557 (7/8)

934281
5/8- 7/8

934232
(11/16 to 7/8)

934026
(7/8)

934026 (7/8)
1011709 (1) 120557
(7/8)

123270
Cprsn (1)
952572
120557 (7/8) (1-3/16)
123270 (1)


949388
949388 (7/8 to
(7/8 to 1-3/16)
1-3/16)
123247
949651 (1-3/16)
(1 to
1-3/16) 949651
1- 1 3/16





123270 (1)
952572 1032770
952572 (1-3/16) (1-1/2)
(1-3/16)








952572
(1 3/16)
952572 1032770
949651 (1-3/16) (1-1/2)
(1 to
1-3/16)
Intake or GS
To Seal
912071
(11/16 to 934026 (7/8)
3/4)
960765
944512 123247
(1-3/16 to
(1 3/16) (1-3/16)
1-1/2)
Seal
to
Seal Seal
926956 Unit Adptr & Cplg
(3/4) 740211 (7/8)
943829 (1-3/16)
960245
151409 (1-3/16 HL)
(1-1/2)
151407 (1-3/16 pre-shimmed)
Coupling
Adapter
1046754
(3/4 to
1-3/16)
960641
1002575
945592 (1-3/16 to 2) (1-1/2 to
(7/8 to 1-1/2)
2-1/4)


Motor
Type 62 & 92
Seal 1000124
To 1042043 (1-1/8 to 1- 1/2)
Motor (7/8 to
(Sgl or UT) 1-3/16) Type 92 HTI
or BOH 120697
(1-1/8 to 1-1/2) Inv
Type 62 SGL: 947986
(2 to 1-3/16)
960294
Type 62 & 92 UT: 948042 (2-1/4 to
(2 to 1- 3/8) (1- 1/2)
Type 92HTI: 121437
(2 to 1-3/8) Inv
Type 62: 933523
(1)


Motor

Motor
Base
or
Sensor



Motor
To
Motor 914259
(CT or LT) (11/16)
Type 92: 110716 Type 62: 944165 (1-3/16)
(1-1/8)
Type 92: 1017623 (1-3/8)
Type 92 HTI
120696 Type 92 HTI to 92 Std: 141712
(1-1/8) Inv (1-3/8 inv to 1-3/8)
Type 62 to 92 Type 92HTI: 121784 (1-3/8) Inv
120862
(1 to 1-1/8) Type 92-62: 141710
(1-3/16 to 1-3/8)
Type 92 - 62
120787
(1-1/8 to 1)
961961
(1-1/2)

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-4 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
CHECK VALVES AND BLEEDER VALVES
DESCRIPTION
CHECK VALVES -up to 2200 psi
CHECK VALVE 2 3/8 - 8rd 2200
CHECK VALVE 2 3/8 - 8rd 2200 SST
CHECK VALVE 2 7/8 - 8rd 2200
CHECK VALVE 2 7/8 - 8rd 2200 SST
CHECK VALVE 3 1/2 - 8rd 2200
CHECK VALVE 3 1/2 - 8rd 2200 SST
CHECK VALVES -up to 5000 psi
CHECK VALVE 2 3/8 - 8rd 5000
CHECK VALVE 2 3/8 - 8rd 5000 SST
CHECK VALVE 2 7/8 - 8rd 5000
CHECK VALVE 2 7/8 - 8rd 5000 SST
CHECK VALVE 3 1/2 - 8rd 5000
CHECK VALVE 3 1/2 - 8rd 5000 SST
BLEEDER VALVES
BLEEDER VALVE 2 3/8 - 8rd
BLEEDER VALVE 2 7/8 - 8rd
BLEEDER VALVE 3 1/2 - 8rd
CASING CHECK & BLEEDER VALVE 4 1/2 - 8rd
CASING CHECK & BLEEDER VALVE 5 1/2 - 8rd
CASING CHECK & BLEEDER VALVE 7 - 8rd
WEIGHT PART
Lbs. Kgs. NUMBER

6 2.72 913939
6 2.72 120169
10 4.54 925206
10 4.54 120168
16 7.26 926386
16 7.26 143565

9 4.08 145935
9 4.08 145936
15 6.80 143316
15 6.80 143317
24 10.89 145937
24 10.89 143327

6 2.72 912501
10 4.54 925339
16 7.26 926394
127400
127402
127403
BREAK OFF PLUGS
BRASS 2, 2 3/8, 2 7/8, and 3 1/2 0.30 0.14 911966
MONEL 2, 2 3/8, 2 7/8, and 3 1/2 0.30 0.14 925354
REDUCING NIPPLES
2 3/8 OD 8rd x 2 7/8 OD 8rd 2.5 1.13 917567
2 3/8 OD 8rd x 3 1/2 OD 8rd 7.5 3.40 917575
2 7/8 OD 8rd x 3 1/2 OD 8rd 7.5 3.40 917583
SHIPPING BOXES w/o Hinges
EQUIPMENT DIA
INSIDE




Type 300-700 Series 7







Type 300-900 Series 12
LENGTH WEIGHT PART
Feet Meters Lbs. Kgs NUMBER
6 1.8 146 66.2 741111
7.5 2.3 188 85.3 741121
12.5 3.8 351 159.2 741112
15.5 4.7 435 197.3 741113
18.5 5.6 500 226.8 741114
23 7.0 621 281.7 741115
26 7.9 750 340.2 741116
28.5 8.7 810 367.4 741117
32 9.8 926 420.0 741118
36 11.0 1042 472.7 741119
7.5 2.3 310 140.6 741124
12 3.7 495 224.5 741120
15 4.6 619 280.8 741127
23 7.0 949 430.5 741125
26 7.9 1073 486.7 741126
34 10.4 1403 636.4 741128

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 5





Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT

MONEL HARDWARE KITS
SERIES TR3 TR4 TR5 TR6 TR7 TR8
PUMP 1054519 1054519 1054691 1054766 1054774
INTAKE 1054519 1054519 1054691 1054766 1054774
GAS SEPARATOR 1054519 1054519 1054691
SEAL 1054527 1054584 1054709 1054782 1054782
MOTOR (SINGLE) 1054535 1054592 1054717 1054790
MOTOR (UT) 1054543 1054600 1054725 1054808
MOTOR (CT) 1054550 1054618 1054733 1059162
MOTOR (LT) 1054568 1054626 1054741 1054816
SENSOR- PRESS & TEMP 1054576 1054683 1054758 1054824
SENSOR - PRESSURE ONLY 1055078 1055086 1055094 1055102
BOLT-ON-BASE 1055078 1055086 1055094 1055102
Notes:
1. Monel bolts and washers are supplied as standard with all downhole equipment. Above monel
hardware kits are available to replace or upgrade equipment and includes all bolts, washers, plugs
and drain and fill components. These components may also be purchased as individual parts from
any Wood Group ESP, Inc. facility. Contact your sales or service representative for individual part
prices.

2. Monel bolts and washers are recommended for use with all components having a corrosion
resistant coating.

3. Screws and lock washers are for the top end connection of the listed equipment.
4. O-rings are not provided in the kits.



MONEL HARDWARE KITS
DESCRIPTION PART NUMBER
FLAME SPRAY COATING APP-83
METAL FLAME SPRAY COATING - TOUCH-UP KIT 922872















Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-6 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT

MOTOR OIL
DESCRIPTION
ROCON #2 MEDIUM - 5 GALLON CAN
ROCON #3 (SYNTHETIC) - 5 GALLON CAN
ROCON #220 (SYNTHETIC - HI-TEMP) - 55 GALLON CAN
WEIGHT PART
Lbs. Kgs. NUMBER
25 11.3 985978
37 16.8 2643022
462 209.6 127295

OIL FILLING COMPONENTS
OIL CAN COMPLETE WITH PUMP, HOSE. ETC 16 7.3 1059270
PUMP 1059288
PUMP HOSE 1059296
SWEDGELOK - FEMALE 1059304
PRESSURE GAGE 1059320
ALEMITE ADAPTER 1059338
CAN, 5 GALLON WITH SEAL 0.60 0.27 1059714
PIPE, 19 X .500 BLACK 127063
PIPE ELBOW 1/2 127064
PIPE NIPPLE 1/2 X 1 1/2 127065
PIPE REDUCER 127066
PIPE TEE 127067
SCREW, HEX HEAD 5/16 X 3/4 127068
PLATE, STEEL 127069
PUMP HANDLE 127070

INSTALLATION CLAMPS
TR3 MOTOR SHOULDER CLAMP 24 10.89 T111
TA PUMP SHOULDER CLAMP 24 10.89 T110
TA PUMP FRICTION CLAMP 24 10.89 T2345
TR3 SEAL FRICTION CLAMP 24 10.89 T2346
TR387 PUMP FRICTION CLAMP 24 10.89 T2166
TR4 MOTOR SHOULDER CLAMP 24 10.89 T478
TD PUMP SHOULDER CLAMP 24 10.89 T479
TD PUMP FRICTION CLAMP 24 10.89 T328
TR5 MOTOR CLAMP 24 10.89 T480
TG PUMP FRICTION CLAMP 24 10.89 T185
TH PUMP FRICTION CLAMP 24 10.89 T2344
TJ PUMP SHOULDER CLAMP 24 10.89 T504
TR7 MOTOR CLAMP 24 10.89 T772
TR7 SEAL FRICTION CLAMP 24 10.89 T2292
TM PUMP SHOULDER CLAMP 24 10.89 T484
TM PUMP FRICTION CLAMP 24 10.89 T773
TN PUMP FRICTION CLAMP 24 10.89 T2287









Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 7





Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT

ADAPTER KITS
DESCRIPTION PART NUMBER
TD PUMP (.875 SHAFT) TO TR5 INTAKE OR RGS 740220
TD PUMP (.687 SHAFT) TO TR5 INTAKE OR RGS 740226
TD PUMP (.625 SHAFT) TO TR5 INTAKE OR RGS 740235
TD INTAKE OR RGS TO TR5 SEAL 740218
TJ / TM / TN INTAKE TO TR5 SEAL 740225
TR7 SEAL TO TR5 MOTOR 740237
TR7 SEAL TO TR7 SEAL 740238
TR4 SEAL TO TR4 SEAL 740211

ADAPTER KITS COMPONENT PARTS
TD INTAKE OR RGS TO TR5 SEAL - BODY
TD INTAKE OR RGS TO TR5 SEAL - COUPLING
TD PUMP (.875 SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099
TD PUMP (.875 SHAFT) TO TR5 INTAKE OR RGS - COUPLING 943803
TD PUMP (.687 SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099
TD PUMP (.687 SHAFT) TO TR5 INTAKE OR RGS - COUPLING 1000454
TD PUMP (.625 SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099
TD PUMP (.625 SHAFT) TO TR5 INTAKE OR RGS - COUPLING 1000447
TD INTAKE OR RGS TO TR5 SEAL - BODY
TD INTAKE OR RGS TO TR5 SEAL - COUPLING
TJ / TM / TN INTAKE TO TR5 SEAL - BODY 740266
TJ / TM / TN INTAKE TO TR5 SEAL - COUPLING 9601112
TR7 SEAL TO TR5 MOTOR - BODY 132718
TR7 SEAL TO TR5 MOTOR - COUPLING
TR7 SEAL TO TR7 SEAL - BODY 960641
TR7 SEAL TO TR7 SEAL - COUPLING
TR4 SEAL TO TR4 SEAL - BODY 740250
TR4 SEAL TO TR4 SEAL - COUPLING 740252


















Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-8 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009





Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
SEAL TO INTAKE ADAPTORS
DESCRIPTION PART NUMBER
338 CL .750 X 338 ESP BOI OR RGS .687 734 734SS 734XX
338 CL .750 X 338 ESP BOI OR RGS .875 735 735SS 735XX
338 CL .750 X 55 ODI PUMP RPS .687 736 736SS 736XX
338 CL .750 X 55 ODI RGS .875 737 737SS 737XX
400 CL .875 X 400 ESP BOI OR RGS .875 700 700SS 700XX
400 CL .875 X 55 ODI PUMP RPS .688 701 701SS 701XX
400 CL .875 X 55 ODI PUMP RPSLA 1.00 702 702SS 702XX
400 CL .875 X 55 ODI RGS .875 703 703SS 703XX
400 CL .875 X 540 ESP BOI OR RGS 1.187 738 738SS 738XX
400 CL .875 X 70 ODI PUMP KPS .875 739 739SS 739XX
400 CL .875 X 70 ODI PUMP KPSLA 1.250 750 750SS 750XX
400 CL .875 X 70 ODI RGS 1.125 751 751SS 751XX
513 CL 1.00 X 55 ODI PUMP RPS .688 710 710SS 710XX
513 CL 1.00 X 55 ODI PUMP RPSLA 1.00 711 711SS 711XX
513 CL 1.00 X 55 ODI RGS .875 712 712SS 712XX
513 CL 1.00 X 400 ESP BOI OR RGS .875 713 713SS 713XX
513 CL 1.00 X 70 ODI PUMP KPS .875 714 714SS 714XX
513 CL 1.00 X 70 ODI PUMP KPSLA 1.250 715 715SS 715XX
513 CL 1.00 X 70 ODI RGS 1.125 716 716SS 716XX
513 CL 1.00 X 540 ESP BOI OR RGS 1.187 717 717SS 717XX
338/375 ESP .750 X 338 CL PUMP OR RGS .625 758 758SS 758XX
338/375 ESP .750 X 338 CL PUMP OR RGS .687 759 759SS 759XX
338/375 ESP .750 X 400 CL PUMP .687 760 760SS 760XX
338/375 ESP .750 X 400 CL HV PMP / RGS .875 761 761SS 761XX
338/375 ESP .750 X 55 ODI PUMP RPS .688 762 762SS 762XX
338/375 ESP .750 X 55 ODI PUMP RPSLA 1.00 763 763SS 763XX
338/375 ESP .750 X 55 ODI RGS .875 764 764SS 764XX
400 ESP .875 X 338 CL PUMP OR RGS .625 765 765SS 765XX
400 ESP .875 X 338 CL PUMP OR RGS .687 766 766SS 766XX
400 ESP .875 X 400 CL PUMP .687 704 704SS 704XX
400 ESP .875 X 55 ODI PUMP RPS .688 705 705SS 705XX
400 ESP .875 X 55 ODI PUMP RPSLA 1.00 706 706SS 706XX
400 ESP .875 X 55 ODI RGS .875 707 707SS 707XX
400 ESP .875 X 513 CL BOI OR RGS .875 768 768SS 768XX
400 ESP .875 X 70 ODI PUMP KPS .875 769 769SS 769XX
400 ESP .875 X 70 ODI PUMP KPSLA 1.25 770 770SS 770XX
400 ESP .875 X 70 ODI RGS 1.125 771 771SS 771XX
400 ESP .875 X 540 ESP BOI OR RGS 1.187 772 772SS 772XX
400 ESP .875 X 400 CL HV PUMP/RGS .875 799 799SS 799XX
540 ESP 1.187 X 400 CL PUMP .687 718 718SS 718XX
540 ESP 1.187 X 55 ODI PUMP RPS .688 719 719SS 719XX
540 ESP 1.187 X 55 ODI PUMP RPSLA 1.00 720 720SS 720XX
540 ESP 1.187 X 55 ODI RGS .875 721 721SS 721XX
540 ESP 1.187 X 513 CL BOI OR RGS .875 722 722SS 722XX
540 ESP 1.187 X 70 ODI PUMP KPS .875 723 723SS 723XX
540 ESP 1.187 X 70 ODI PUMP KPSLA 1.250 724 724SS 724XX
540 ESP 1.187 X 70 ODI RGS 1.125 725 725SS 725XX
540 ESP 1.187 X 400 ESP BOI OR RGS .875 740 740SS 740XX
540 ESP 1.187 X 400 CL HV PMP/RGS .875 773 773SS 773XX
540 ESP 1.187 X 562 CL PUMP 1.187 774 774SS 774XX
Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 9





Wood Group ESP, Inc.
MISCELLANEOUS EQUIPMENT
SEAL TO INTAKE ADAPTORS
DESCRIPTION PART NUMBER
55 ODI .875 X 338 CL PUMP OR RGS .625 785 785SS 785XX
55 ODI .875 X 338 CL PUMP OR RGS .687 786 786SS 786XX
55 ODI .875 X 400 CL HV PMP / RGS .875 787 787SS 787XX
55 ODI .875 X 513 CL BOI OR RGS .875 788 788SS 788XX
55 ODI .875 X 562 CL PUMP 1.187 789 789SS 789XX
55 ODI .875 X 400 ESP BOI OR RGS .875 708 708SS 708XX
55 ODI .875 X 400 CL PUMP .687 709 709SS 709XX
55 ODI .875 X 540 ESP BOI OR RGS 1.187 790 790SS 790XX
70 ODI KTE 1.00 X 400 CL PUMP .687 726 726SS 726XX
70 ODI KTE 1.00 X 400 ESP BOI OR RGS .875 727 727SS 727XX
70 ODI KTE 1.00 X 513 CL BOI OR RGS .875 728 728SS 728XX
70 ODI KTE 1.00 X 540 ESP BOI OR RGS 1.187 729 729SS 729XX
70 ODI KTE 1.00 X 400 CL HV PMP / RGS .875 791 791SS 791XX
70 ODI KTE 1.00 X 562 CL PUMP 1.187 792 792SS 792XX
70 ODI KETM 1.125 X 400 CL PUMP .687 730 730SS 730XX
70 ODI KETM 1.125 X 400 ESP BOI OR RGS .875 731 731SS 731XX
70 ODI KETM 1.125 X 513 CL BOI OR RGS .875 732 732SS 732XX
70 ODI KETM 1.125 X 540 ESP BOI / RGS 1.187 733 733SS 733XX
70 ODI KETM 1.125 X 400 CL HV PMP/RGS .875 795 795SS 795XX
70 ODI KETM 1.125 X 562 CL PUMP 1.187 796 796SS 796XX
MOTOR TO SEAL ADAPTORS
375 CL X 325 / 375 ESP .75 798 798SS 798XX
450 CL 1.00 X 400 ESP .875 800 800SS 800XX
450 CL 1.00 X 540 ESP 1.187 801 801SS
450 CL 1.00 X 55 ODI .875 802 802SS
450 CL 1.00 X 70 ODI 1.125 803 803SS
544 CL 1.125 X 540 ESP 1.187 804 804SS
544 CL 1.125 X 70 ODI 1.125 805 805SS
562 CL 1.250 X 540 1.187 806 806SS 806XX
562 CL 1.250 X 70 ODI 1.125 807 807SS
375 ESP X 338 CL .750 809 809SS
456 ESP 1.125 X 400 CL .875 810 810SS
456 ESP 1.125 X 513 CL 1.00 811 811SS
456 ESP 1.125 X 55 ODI .875 812 812SS
456 ESP 1.125 X 70 ODI 1.125 813 813SS
456 ESP 1.187 X 400 CL .875 814 814SS
456 ESP 1.187 X 513 CL 1.00 815 815SS
456 ESP 1.187 X 55 ODI .875 816 816SS
456 ESP 1.187 X 70 ODI 1.125 817 817SS
540 ESP 1.187 X 513 CL 1.00 818 818SS
540 ESP 1.187 X 70 ODI 1.125 819 819SS
540 ESP 1.375 X 513 CL 1.00 820 820SS
540 ESP 1.375 X 70 ODI 1.125 821 821SS
55 ODI 1.00 X 400 CL .875 822 822SS
55 ODI 1.00 X 513 CL 1.00 823 823SS
55 ODI 1.00 X 400 ESP .875 824 824SS 824XX
55 ODI 1.00 X 540 ESP 1.187 825 825SS
70 ODI 1.312 X 513 CL 1.00 826 826SS
70 ODI 1.312 X 540 ESP 1.187 827 827SS 827XX

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com
Page-10 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009

Date:
Company:
Well Name:
Reservoir:
Field Name:
Location:
Analyst:
Comments
Well Data
MD TVD OD Weight Grade Con- ID Drift
(ft | m) (ft | m) (in | mm) (lb/ft | kg/m) nection (in | mm) (in | mm)
Base Prod. Interval
Datum MD: ft | m Datum Temperature: F | C
Datum TVD: ft | m Wellhead temperature: F | C
Deviation Survey
MD TVD Angle MD TVD Angle
( ft | m ) ( ft | m ) ( deg ) ( ft | m ) ( ft | m ) ( deg )
DLS
( /100' | 90m )
DLS
( /100' | 90m )
PBTD
Tubing
Tubing
Casing
Liner
Liner
Open Hole
Top Prod. Interval
Sandstone Limestone
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 1
Shaft HP Limitations
These charts are intended as general guidelines
only. Refer to Technical Bulletins or Application
Briefs for most recent detailed information. (For more
information, contact your Wood Group ESP
representative.)
COMPONENT
STANDARD
MATERIAL
HIGH
STRENGTH
ULTRA
HIGH
STRENGTH
MOTORS 4130 4130 HS
SEALS
MONEL K-500
OR
NITRONIC 50
INCONEL 718
INCONEL 718
HS
GAS
SEPARATORS
NITRONIC 50 HS INCONEL 718
INCONEL 718
HS
PUMPS
MONEL K-500
OR
NITRONIC 50
INCONEL 718
INCONEL 718
HS
TABLE 1

SERIES
SHAFT
DIA
MATL
HP @
60 HZ
HP @
50 HZ
4130 STEEL 121 100
TR-3 UT
4130 HS STEEL 149 124
4130 STEEL 81 67
TR-3 CT
4130 HS STEEL 109 91
4130 STEEL 100 83
TR-3 UT HTI
4130 HS STEEL 120 100
4130 STEEL 60 50
TR-3 CT HTI
4130 HS STEEL 80 67
TR3-UT-HTI-HP 4130 HS STEEL 162 136
TR3-CT-HTI-HP
0.984
4130 HS STEEL 122 103

E37 HSS 0.984 4130 HS STEEL 270 225

TR-4 STD 4130 STEEL 490 408
TR-4 HSS
1.181
4130 HS STEEL 662 550

TR-5/E56 STD 4130 STEEL 775 645
TR-5/E56 HSS
1.377
4130 HS STEEL 1050 870
TABLE 2 MOTORS

SERIES
SHAFT
DIA
MATERIAL
HP @
60 HZ
HP @
50 HZ
TR-3 STD NITRONIC-50 HS 125 104
TR-3 HSS
0.687
INCONEL 718 200 167

TR-387/TR-4 STD NITRONIC-50 HS 256 213
TR-387/TR-4 HSS INCONEL 718 410 342
TR-4 UHSS
0.875
INCONEL-718 HS 522 435

TR-5 / TR-538 /
TR-675 STD
NITRONIC-50 HS 637 531
TR-5 / TR-538 /
TR-675 HSS
1.188
INCONEL 718 1019 849
TABLE 3 GAS SEPARATORS

SERIES
SHAFT
DIA
MATERIAL
HP @
60 HZ
HP @
50 HZ
TA STD NITRONIC-50 HS 125 104
TA HSS
0.687
INCONEL 718 200 167

TR-387 / TD STD NITRONIC-50 HS 256 213
TD HSS INCONEL 718 410 342
TD UHSS
0.875
INCONEL-718 HS 522 435

TE/TG/TH/TJ/TM STD NITRONIC-50 HS 637 531
TE/TG/TH/TJ/TM HSS INCONEL 718 1019 849
TE/TG/TH/TJ/TM UHSS
1.188
INCONEL-718 HS 1350 1125

TN STD 1.5 NITRONIC-50 HS 1000 833
TABLE 4 INTAKES

SERIES
SHAFT
DIA
MATL
HP @
60 HZ
HP @
50 HZ
TR-3 STD
MONEL /
NITRONIC
160 133
TR-3 HSS
0.750
INCONEL 718 256 213

TR-4 STD
MONEL /
NITRONIC
256 213
TR-4 HSS INCONEL 718 410 342
TR-4 UHSS
0.875
INCONEL 718 HS 522 435

TR-5 STD
MONEL /
NITRONIC
637 531
TR-5 HSS
1.188
INCONEL 718 1019 849

TR-5 AR
MONEL /
NITRONIC
637 531
TR-5 AR HSS INCONEL 718 1019 849
TR-5 AR UHSS
1.375
(Has a
1.188
spline) INCONEL 718 HS 1340 1100

TR-562 STD
MONEL /
NITRONIC
690 575
TR-562 HSS
1.375
INCONEL 718 1100 917

TR-7 STD
MONEL /
NITRONIC
1000 833
TR-7 HSS
1.500
INCONEL 718 1600 1333

TR-950 STD
MONEL /
NITRONIC
2100 1750
TR-950 HSS
2.000
INCONEL 718 3375 2813
TABLE 5 SEALS

SERIES
SHAFT
DIA
MATL
HP @
60 HZ
HP @
50 HZ
TD STD
MONEL /
NITRONIC
44 37
TD HSS
0.500
INCONEL 718 70 58

TA/TD STD
MONEL /
NITRONIC
94 78
TA/TD HSS
0.625
INCONEL 718 150 125

TA/TD - STD
MONEL /
NITRONIC
125 104
TA/TD HSS INCONEL 718 200 167
TA/TD UHSS
0.687
INCONEL 718 HS 255 212

TD/TG/TE - STD
MONEL /
NITRONIC
256 213
TD/TG/TE - HSS INCONEL 718 410 342
TD/TG/TE - UHSS
0.875
INCONEL 718 HS 522 435

TG/TE/TH- STD MONEL K500 375 312
TG/TE/TH - HSS INCONEL 718 600 500
TG/TE/TH - UHSS
1.000
INCONEL 718 HS 765 638

TE/TH/TJ/TM STD
MONEL /
NITRONIC
637 531
TE/TH/TJ/TM HSS INCONEL 718 1019 849
TE/TH/TJ/TM UHSS
1.188
INCONEL 718 HS 1300 1083

TM STD
MONEL /
NITRONIC
760 633
TM HSS INCONEL 718 1216 1013
TM UHSS
1.375
INCONEL 718 HS 1550 1290

TN STD
MONEL /
NITRONIC
1000 833
TN HSS INCONEL 718 1600 1333
TN UHSS
1.500
INCONEL 718 HS 2040 1700
TABLE 6 PUMPS

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 2

ENGINEERING TABLES
Pumps 50 Hz 2917 RPM
Const. Stage
Housing
Pressure
Limit
PSI
Model Series
O.D.
MM
Flt. Cprsn. Pancake
Mixed
Flow
Recommended
Operating
Range
M
3
/Day
Maximum
Downthrust
Per Stage
Cprsn.
Pump
Lbs.
BHP
per
Stage

S/O
Head
Per
Stage
Meters Std.
Hi.
Pr.

TA-400 X X X 40-72 15.1 0.07 5.0
TA-550 X X X 53-93 15.7 0.08 4.8
TA-900 X X X 87-140 15.8 0.10 4.6
TA-1200 X X X 120-200 15.5 0.12 4.4
TA-1500 X X X 132-265 16.0 0.18 4.0
TA-2200
338 85.85
X X 166-364 0.19 4.2
6000 6000

TD-150 X X X 11-37 17.0 0.05 5.0
TD-300 X X X 26-60 18.4 0.06 5.1
TD-460 X X X 40-79 22.2 0.08 5.9
TD-650 X X X 60-106 20.2 0.13 7.0
TD-850 X X X 73-135 21.0 0.18 6.9
TD-1250 X X X 106-199 30.1 0.30 7.4
TD-1750 X X X 159-278 11.0 0.22 6.2
TD-2200 X X X 185-371 12.4 0.36 7.0
TD-3000 X X X 265-490 11.9 0.37 5.9
TD-4300 X X X 397-689 15.6 0.58 5.9
TD-6000
400 101.60
X X X 464-994 18.8 0.82 6.2
5000 6000

TG-4000 513 130.30 X X X 424-636 29.5 0.90 11.4 5000 6000

TE-1500 X X X 106-298 34.7 0.79 15.2
TE-2700 X X X 199-437 36.8 0.90 14.8
TE-3300 X X X 291-596 41.4 1.59 15.9
TE-4200 X X X 344-649 64.6 1.78 14.4
TE-5500 X X X 464-967 35.4 1.63 13.1
TE-7000 X X X 530-1285 25.7 1.99 13.5
TE-7200 X X X 530-1285 25.7 1.99 13.3
TE-11000
538 135.65
X X 1060-1855 49.3 2.55 10.6
6000 6000

TH-15000 X X 1325-2517 49.3 5.27 14.8
TH-20000
562 142.75
X X 1987-3113 70.1 6.77 15.5
3000 3600

TJ-7500 X X 662-1457 59.0 3.41 17.0
TJ-9000 X X 662-1722 81.9 5.09 24.8
TJ-12000 X X 994-2385 100.0 6.60 22.0
TJ-20000
675 171.45
X X 1590-3445 132.0 7.31 21.4
3000 3600

A X X 1855-3180 232.6 11.28 31.1
B X X 1722-3047 194.7 8.33 26.0
TM
19000
C X X 1656-2981 158.3 7.24 21.2
TM
24000
A X X 1855-4239 229.2 17.36 31.3
B X X 2650-3842 193.5 16.38 26.5
C X X 2583-3776 154.9 11.92 21.2
TM25000
862 218.95
X X 1855-4504 253.5 20.41 35.1
2000 2400

A X X 4107-5962 642.4 34.08 45.5
B X X 3710-5697 534.8 25.52 37.9
TN
35000
C
950 241.30
X X 3378-5167 448.1 19.82 31.8
2300 2760

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 3
ENGINEERING TABLES
Pumps 50 Hz 2917 RPM

Maximum Number of Stages Using
Shaft
Thrust Brg.
Load Capacity
Lbs.
Thrust Brg.
(Ref Seal Section)
BHP Limit Floater Pump Cprsn. Pump
Shaft Housing
Model
Dia.
MM
Area
MM
2
Std. HS
Std.
@230F
(Max.) #
Hi-Ld
@250F
(Max.) #
Std.
@230F
(Max.) #
Hi-Ld
@250F
(Max.) #
Hi-Ld
@250F
(Max.) #
Std.
#
HS
#
Std.
#
Hi Pr
#
TR 3 Seal Section
TA-400 413 1181 165 1231 1969 870 870
TA-550 414 1184 159 967 1547 872 872
TA-900 435 1243 159 796 1274 916 916
TA-1200
15.875 197.93 78 125
461 1316 161 645 1031 969 969
TA-1500 413 1179 157 581 929 1050 1050
TA-2200
17.463 239.50 104 167


875


2500
391 1118 545 873 998 998
TR 4 Seal Section
TD-150 12.700 126.68 37 58 715 3965 323 782 1244 708 849
TD-300 448 2485 299 1231 1969 693 832
TD-460 326 1807 248 752 1203 504 605
TD-650 324 1796 272 589 942 501 601
TD-850
15.875 197.93 78 125
329 1824 262 437 699 509 610
TD-1250 254 1408 183 353 565 475 570
TD-1750 303 1682 501 474 758 568 681
TD-2200
17.463 239.50 104 167
269 1489 442 286 457 502 603
TD-3000 196 1087 460 576 922 594 713
TD-4300 197 1091 352 365 584 596 715
TD-6000

22.225

387.95

213

341
992 5500
188 1042 293 261 418 570 684
TR 5 Seal Section
TG-4000 25.400 506.71 313 500 2008 10200 157 800 346 346 554 308 370

TE-1500 154 784 294 269 431 277 277
TE-2700 159 806 277 236 378 285 285
TE-3300
22.225 387.95 213 341
148 752 246 134 214 266 266
TE-4200 125 635 158 175 281 294 294
TE-5500 137 697 288 191 306 322 322
TE-7000 133 677 397 157 251 313 313
TE-7200
25.400 506.71 313 500
135 687 397 157 251 317 317
TE-11000 30.163 715.14 531 849
2008 10200
207 208 333 399 399

TH-15000 207 101 161 143 171
TH-20000
30.163 715.14 531 849 2008 10200
145 78 125 137 164
TR562 Seal Section
TJ-7500 296 155 249 124 149
TJ-9000 214 104 167 85 102
TJ-12000 175 80 129 96 115
TJ-20000
30.163 715.14 531 849 17500
133 73 116 99 119

A 75 47 75 45 54
B 90 64 102 54 65
TM
19000
C 111 73 117 67 80
A 76 31 49 44 53
B 90 32 52 53 64
TM
24000
C
30.163 715.14 531 849
113 45 71 67 80
TM25000 34.925 958.00 633 1013
17500
69 31 50 40 48
A 27 24 39 36 43
B 33 33 52 43 51
TN
35000
C

38.100

1140.09

833

1333

17500
39 42 67 51 61

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 4
ENGINEERING TABLES
Pumps 60 Hz 3500 RPM
Const. Stage
Housing
Pressure
Limit
PSI
Model Series
O.D.
Inches
Flt. Cprsn. Pancake
Mixed
Flow
Recommended
Operating
Range - BPD
Maximum
Downthrust
Per Stage
Cprsn.
Pump
Lbs.
BHP
per
Stage

S/O
Head
Per
Stage
Ft. Std.
Hi.
Pr.

TA-400 338 3.38 X X X 300-540 21.8 0.12 23.5 6000 6000
TA-550 X X X 400-700 22.6 0.14 22.9
TA-900 X X X 660-1060 22.7 0.17 21.8
TA-1200 X X X 900-1500 22.3 0.21 20.6
TA-1500 X X X 1000-2000 23.0 0.31 19
TA-2200 X X 1250-2750 0.33 20

TD-150 X X X 80-280 24.5 0.081 23.5
TD-300 X X X 200-450 26.5 0.11 24.0
TD-460 X X X 300-600 32.0 0.18 33
TD-650 X X X 450-800 29.1 0.23 33.2
TD-850 X X X 550-1020 30.2 0.31 32.7
TD-1250 X X X 800-1500 43.3 0.51 35.0
TD-1750 X X X 1200-2100 15.8 0.38 29.3
TD-2200 X X X 1400-2800 17.9 0.63 33.1
TD-3000 X X X 2000-3700 17.2 0.64 28.0
TD-4300 X X X 3000-5200 22.5 1.01 27.9
TD-6000
400 4.00
X X X 3500-7500 27.0 1.41 29.2
5000 6000

TG-4000 513 513 X X X 3200-4800 42.5 1.56 54.0 5000 6000

TE-1500 X X X 800-2250 50.0 1.37 72.0
TE-2700 X X X 1500-3300 53.0 1.56 70.0
TE-3300 X X X 2200-4500 59.7 2.75 75.0
TE-4200 X X X 2600-5400 93 3.08 68.0
TE-5500 X X X 3500-7300 51.0 2.82 62.0
TE-7000 X X X 4000-9700 37.0 3.44 63.8
TE-7200 X X X 4000-9550 37.0 3.44 62.9
TE-11000
538 5.38
X X 8000-14000 71.0 4.41 50.0
6000 6000

TH-15000 X X 10000-19000 71.0 9.10 70.0
TH-20000
562 5.62
X X 15000-23500 101.0 11.70 73.0
3000 3600

TJ-7500 X X 5000-11000 85.0 5.90 80.5
TJ-9000 X X 5000-13000 118.0 8.80 117.0
TJ-12000 X X 7500-18000 144.0 11.40 104.0
TJ-16000 X X 12000-18000 145.0 12.25 93.5
TJ-20000
675 6.75
X X 12000-26000 190.0 12.63 101.0
3000 3600

A X X 14000-24000 335.0 19.50 147.0
B X X 13000-23000 280.3 14.40 123.0
TM
19000
C X X 12500-22500 227.9 12.51 100.0
A X X 14000-32000 330.0 30.0 150.2
B X X 20000-29000 278.7 28.30 125.0
TM
24000
C X X 19500-28500 223.0 20.60 100.0
TM25000
862 8.62
X X 14000-34000 365.0 35.26 166.0
2000 2400

A X X 31000-45000 925.0 58.89 215.0
B X X 28000-43000 770.1 44.10 179.0
TN
35000
C
950 9.50
X X 25500-39000 645.3 34.25 150.0
2300 2760


Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 5
ENGINEERING TABLES
Pumps 60 Hz 3500 RPM

Maximum Number of Stages Using
Shaft
Thrust Brg.
Load Capacity
Lbs.
Thrust Brg.
(Ref Seal Section)
BHP Limit Floater Pump Cprsn. Pump
Shaft Housing
Model
Dia.
In.
Area
In.
2
Std. HS
Std.
@230F
(Max.)
#
Hi-Ld
@250F
(Max.) #
Std.
@230F
(Max.) #
Hi-Ld
@250F
(Max.) #
Hi-Ld
@250F
(Max.) #
Std.
#
HS
#
Std.
#
Hi
Pr
#
TR 3 Seal Section
TA-400 320 881 126 783 1253 590 590
TA-550 329 904 122 671 1074 605 605
TA-900 345 950 121 553 885 636 636
TA-1200
0.625 0.3068 94 150
366 1005 123 448 716 673 673
TA-1500 328 901 120 403 645 729 729
TA-2200
0.688 0.3712 125 200
1000 2750
311 854 379 606 693 693
TR 4 Seal Section
TD-150 0.500 0.1963 44 70 596 3004 245 543 864 491 590
TD-300 373 1882 226 855 1367 481 578
TD-460 272 1369 188 522 836 350 420
TD-650 270 1361 206 409 654 348 417
TD-850
0.625 0.3068 94 150
274 1382 199 303 485 353 424
TD-1250 212 1067 139 245 392 330 396
TD-1750 253 1274 380 329 526 394 473
TD-2200
0.688 0.3712 125 200
224 1128 335 198 317 349 419
TD-3000 163 823 349 400 640 413 495
TD-4300 164 826 267 253 406 414 497
TD-6000

0.875

0.6013

256

410
1190 6000
157 789 222 182 290 396 475
TR 5 Seal Section
TG-4000 1.000 0.7854 375 600 2410 11000 131 599 259 240 385 214 257

TE-1500 129 587 220 187 299 193 193
TE-2700 132 604 208 164 263 198 198
TE-3300
0.875 0.6013 256 410
123 563 184 93 149 185 185
TE-4200 104 476 118 122 195 204 204
TE-5500 114 522 216 133 213 224 224
TE-7000 111 507 297 109 174 217 217
TE-7200
1.000 0.7854 375 600
113 514 297 109 174 220 220
TE-11000 1.188 1.1085 637 1019
2410 11000
155 144 231 277 277

TH-15000 155 70 112 99 119
TH-20000
1.188 1.1085 637 1019
109 54 87 95 114
TR562 Seal Section
TJ-7500 226 108 173 86 103
TJ-9000 163 72 116 59 71
TJ-12000 134 56 89 67 80
TJ-20000
1.188 1.1085 637 1019 19250
101 50 81 69 82
A 1.188 1.1085 637 1019 57 33 52 31 38
B 69 44 71 38 45
TM
19000
C 84 51 81 46 55
A 58 21 34 31 37
B 69 23 36 37 44
TM
24000
C 86 31 49 46 55
TM25000 1.375 1.4849 760 1216
19250
53 22 34 28 33
A 21 17 27 25 30
B 25 23 36 30 36
TN
35000
C
1.500 1.7671 1000 1600 19250
30 29 47 35 43

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 6
ENGINEERING TABLES
Model STD Motors
300 Series Motors (3.75 O.D.) 400 Series Motors (4.56 O.D.) 500 Series Motors (5.44 O.D.)
H.P. Volts H.P. Volts H.P. Volts
60
Hz
50
Hz
60
Hz
50
Hz
Amps

60
Hz
50
Hz
60 Hz
50
Hz
Amps

60
Hz
50
Hz
60
Hz
50
Hz
Amps
7.5 6.3 410 342 14 10 8.3 435 363 15 290 241 45
10.5 8.8 390 325 20.5 435 363 23 440 367 29
315 263 35.5
15 12.5
610 508 16 755 629 17
400 333 28 450 375 28.5
20 16.7
1020 850 12 15 12.5
900 750 14
20 16.7
750 625 17 435 363 45
18 15 265 220 51 410 342 39 710 592 28
387 323 38 690 575 22
30 25
1215 1013 16
19.5 16.3
630 525 23
25 20.8
810 675 20 435 363 60
330 275 51.5 425 354 44.5 730 608 36
440 367 38.5
30 25
750 625 25.5 880 733 30 22.5 18.8
730 608 23 400 333 55
40 33.3
1325 1104 20
370 308 51 675 563 33 450 375 72
500 417 37
35 29.2
750 625 28 725 604 45 25.5 21.3
630 525 30 420 350 62 905 754 34
770 642 33 1270 1058 25
880 733 29
50 41.7
1375 1146 22

40 33.3
1295 1079 20 425 354 91

675 563 47 645 538 59
815 679 39 870 725 45
955 796 33 970 808 39

1070 892 31 1085 904 35

50 41.7
1210 1008 27
60 50
1320 1100 30

640 533 59 755 629 60
810 675 47 1015 846 45

970 808 39
70 58.3
1265 1054 35
1330 1108 29 865 721 60

60 50
1945 1620 20 1160 967 45
540 450 82.5
80 66.6
2180 1817 23
750 625 60 705 588 90
945 788 47 835 696 76
1135 946 39 1070 892 60
1310 1092 35 1255 1046 50

70 58.3
1885 1570 24 1450 1208 45
635 529 80
100 83.3
2170 1808 29
860 717 60 855 713 88
1085 904 46 1030 858 73
1310 1092 39 1295 1079 59

80 66.7
2155 1796 24 1450 1208 45
90 75 710 592 81
120 100
2165 1804 33
960 800 59 925 771 88
Model E56 Motors
1135 946 50
130 108.3
1125 938 67
H.P. Volts 1220 1017 46 985 821 90
1460 1216 39 1210 1008 67 60
Hz
50
Hz
60
Hz
50
Hz
Amps
1930 1608 31
140 116.7
2015 1679 44
200 166.7 1403 1169 86 100 83.3 775 646 84 1075 896 87
250 208.3 1754 1462 86 1075 896 59 1240 1033 76
2055 1712 73 1355 1129 46
150 125
2105 1754 44
2355 1962 64 2205 1838 28.5 825 688 122
3858 3215 40

1190 992 60

1115 929 88.5
300 250 1744 1453 104 1487 1239 48 1423 1186 71
2105 1754 86
110 91.7
2380 1983 30 2003 1669 50
350 291.7 2034 1695 104 930 775 84
160 133.3
2185 1821 46
2455 2046 86 1040 867 76 945 788 120
3718 3098 58 1125 938 70 1275 1063 89
400 333.3 1847 1539 135 1295 1079 59 1945 1621 59
2325 1937 104 1625 1354 46
180 150
2260 1883 50
2806 2338 86
120 100
2245 1871 35 1100 917 115
2616 2180 104 1415 1179 89
450 375 1960 1633 140
200 166.7
2140 1783 54
2350 1958 116 1135 946 127
3698 3081 75
225 187.5
2235 1863 64

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 7
ENGINEERING TABLES
Model THD Motors
300 Series Motors (3.75 O.D.) 400 Series Motors (4.56 O.D.) 500 Series Motors (5.44 O.D.)
H.P. Volts H.P. Volts H.P. Volts
60
Hz
50
Hz
60
Hz
50
Hz
Amps

60
Hz
50
Hz
60
Hz
50
Hz
Amps

60
Hz
50
Hz
60
Hz
50
Hz
Amps
10 8.3 455 379 17 15 12.5 505 421 20 30 25 515 429 37
15 12.5 445 371 26 20 16.5 480 400 28 880 733 22
25 20.8 385 320 49 675 563 20 1190 992 15
490 408 39 30 25 525 437 38 45 37.5 505 421 58
1100 917 19 870 725 23 830 691 36
30 25 455 379 50 35 29.5 465 387 49 1415 1179 21
745 621 30 780 650 28 60 50 505 421 77
35 29.2 390 325 68 915 763 25 850 708 46
520 433 51 45 37.5 495 413 59 1025 854 39
865 721 30 870 725 34 1545 1288 26
40 33.3 440 367 68 50 41.5 455 379 71 75 62.5 525 437 93
595 496 49 770 642 42 845 704 58
750 625 40 855 710 36 1055 879 44
60 50 490 408 83 1480 1233 32
895 746 44 1605 1338 28
1025 854 39 90 75 750 625 76
1505 1254 27 1015 846 58

75 62.5 785 654 63 1130 942 50
945 787 52 1265 1041 45
1110 925 44 1540 1283 39

1245 1037 41 105 87.5 880 733 77
1405 1171 36 1185 988 58

90 75 745 620 79 1475 1229 45
940 783 63 120 100 1010 841 77

1130 941 52 1355 1129 58
1545 1288 39 2545 2121 30
2260 1883 27 150 125 975 812 98
105 87.5 630 525 110 1250 1041 77
870 725 80 1465 1221 65
1100 917 63 1690 1408 58
1320 1100 52 2530 2108 37
1525 1271 47 180 150 1200 1000 94
120 100 740 616 107 1510 1258 76
1000 833 80 2030 1691 58
1260 1050 61 2525 2104 43
1525 1271 52 195 162.5 1310 1092 87
2505 2088 32 210 175 1150 958 116
135 112.5 825 687 108 1410 1175 87
1115 929 79 2350 1958 57
1320 1100 67 225 187.5 1255 1046 112

1420 1183 61 1445 1204 98
1695 1413 52 2455 2046 57
2245 1871 41 240 200 1300 1083 114
150 125 900 750 112 1660 1383 92
1250 1041 79 2335 1946 65
1575 1313 61 2550 2125 59
2565 2138 38 270 225 1485 1238 115
165 137.5 1385 1154 80 2270 1892 76
1728 1440 64 2635 2196 65
2765 2304 40 300 250 1285 1071 149
180 150 1080 900 112 1510 1258 127
1210 1008 101 1650 1375 115


1310 1091 93

2495 2079 70
1505 1254 79
2610 2175 47

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 8
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 9
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 10
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 11
Copyright Wood Group ESP March 2009
ENGINEERING TABLES

API Tubular Goods
SIZE
INCHES (MM)
DIAMETER
INCHES / MM
NOMINAL OD

THREAD

WEIGHT
LB / FT OD ID DRIFT
COUPLINGOD
INCHES / MM
API LINE PIPE:
1- (31.8) 11-1/2 V 2.30 1.660 / 42.2 1.380 / 35.1 2.054 / 52.2
1- (38.1) 11 to 11-1/2V 2.75 1.900 / 48.3 1.610 / 40.1 2.200 / 55.9
2 (50.8) 2-3/8 (60.3) 11-1/2 V 3.75 2.375 / 60.3 2.067 / 52.5 2.875 / 73.0
3 (76.2) 3-1/2 (88.9) 8 V 7.70 3.500 / 88.9 3.068 / 77.9 4.000 / 101.6
4 (101.6) 4- (114.3) 8 V 11.00 4.500 / 114.3 4.026 / 102.3 5.200 / 132.1
6 (152.4) 6-5/8 (168.4) 8 V 19.45 6.625 / 168.3 6.065 / 167.8 7.390 / 187.7
8 (203.2) 8-5/8 (219.2) 8 V 25.55 8.625 / 219.1 8.071 / 205.0 9.625 / 244.5
API TUBING (NON UPSET):
1- (38.1) 10 RD 2.75 1.900 / 48.3 1.610 / 40.9 1.516 / 38.5 2.200 / 55.8
2 (50.8) 2-3/8 (60.3) 10 RD 4.00 2.375 / 60.3 2.041 / 51.8 1.947 / 49.5 2.875 / 73.03
2- (63.5) 2-7/8 (73.0) 10 RD 6.40 2.875 / 73.0 2.441 / 62.0 2.347 / 59.6 3.500 / 88.9
3 (76.2) 3- (88.9) 10 RD 7.70 3.500 / 88.9 3.068 / 77.9 2.943 / 74.8 4.250 / 108.0
3- (88.9) 4 (101.6) 8 RD 9.50 4.000 / 101.6 3.548 / 90.1 3.423 / 87.0 4.750 / 120.7
API TUBING (EXTERNAL UPSET):
1- (38.1) 10 RD 2.90 1.900 / 48.3 1.610 / 40.9 1.516 / 38.5 2.500 / 63.5
2 (50.8) 2-3/8 (60.3) 8 RD 4.70 2.375 / 60.3 1.995 / 50.7 1.901 / 48.3 3.063 / 77.8
2- (63.5) 2-7/8 (73.0) 8 RD 6.50 2.875 / 73.0 2.441 / 62.0 2.347 / 59.61 3.668 / 93.2
3 (76.2) 3- (88.9) 8 RD 9.30 3.500 / 88.9 2.992 / 76.0 2.867 / 72.8 4.500 / 114.3
3- (88.9) 4 (101.6) 8 RD 11.00 4.000 / 101.6 3.476 / 88.3 3.351 / 85.1 5.000 / 127.0
4 (101.6) 4- (114.3) 8 RD 12.75 4.500 / 114.3 3.958 / 100.5 3.833 / 97.4 5.563 / 141.3
API TUBING REGULAR CASING:
8 RD 9.50 4.090 / 103.9 3.965 / 100.7
8 RD 11.60 4.000 / 101.6 3.875 / 98.43
4- (114.3)
8 RD 13.50
4.500 / 114.3
3.920 / 99.56 3.795 / 96.39
5.000 / 127.0
8 RD 14.00 5.012 / 127.3 4.887 / 124.1
8 RD 17.00 4.892 / 124.3 4.767 / 121.1
8 RD 20.00 4.778 / 121.4 4.653 / 118.2


5- (139.7)
8 RD 23.00

5.500 / 139.7
4.670 / 118.61 4.545 / 115.44
6.050 / 153.7
8 RD 17.00 6.135 / 155.8 6.010 / 152.7
8 RD 24.00 5.921 / 150.4 5.796 / 147.2
8 RD 28.00 5.791 / 147.09 5.666 / 143.91

6-5/8 (168.4)
8 RD 32.00
6.625 / 168.4
5.675 / 144.14 5.550 /140.97
7.390 / 187.7
8 RD 20.00 6.456 / 164.0 6.331 / 160.8
8 RD 23.00 6.366 / 161.7 6.241 / 158.5
8 RD 26.00 6.276 / 159.4 6.151 / 156.2
8 RD 29.00 6.184 / 157.07 6.059 / 153.89


7 (177.8)
8 RD 32.00

7.000 / 177.8
6.094 / 154.78 5.959 / 151.35
7.656 / 194.5
8 RD 28.00 8.017 / 203.6 7.892 / 200.5
8 RD 32.00 7.921 / 201.19 7.796 / 198.0
8 RD 36.00 7.825 / 198.8 7.700 / 195.6

8-5/8 (219.1)
8 RD 40.00
8.625 / 219.1
7.725 / 196.21 7.600 / 193.04
9.625 / 244.5
8 RD 36.00 8.921 / 226.6 8.765 /222.6
8 RD 40.00 8.835 / 224.4 8.679 / 220.5
8 RD 47.00 8.681 / 220.49 8.525 / 216.53

9-5/8 (244.5)
8 RD 53.50
9.625 / 244.5
8.535 / 216.78 8.379 / 212.82
10.625/ 269.9
8 RD 40.50 10.050 / 255.3 9.894 / 251.3
10-3/4 (273.1)
8 RD 55.50
10.750/ 273.1
9.760 / 247.9 9.604 / 243.9
11.750/ 298.5
8 RD 48.00 12.715/ 323.0 12.559/ 319.0
13-3/8 (339.9)
8 RD 68.00
13.375/ 339.9
12.415/ 315.3 12.259/ 311.4
14.375/ 365.1
Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 12
Intentionally left Blank

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 13
ENGINEERING TABLES

Gravity Correction Table
Weight (Density) Fluid Head
Gallon Cubic
Foot
Barrel Pressure per Foot Height per Pound
Buoyancy
Factor

Degrees
API

Specific
Gravity
Pounds Lbs / Sq In Feet Totally Immersed
60.0 0.739 6.16 46.1 259.0 0.320 3.13 0.906
59.0 0.743 6.20 46.4 260.0 0.322 3.11 0.905
58.0 0.747 6.23 46.6 262.0 0.324 3.09 0.905
57.0 0.751 6.26 46.8 263.0 0.325 3.08 0.904
56.0 0.755 6.30 47.1 265.0 0.327 3.06 0.904

55.0 0.759 6.33 47.4 266.0 0.329 3.04 0.903
54.0 0.763 6.36 47.6 267.0 0.330 3.03 0.903
53.0 0.767 6.40 47.9 269.0 0.332 3.01 0.902
52.0 0.771 6.43 48.1 270.0 0.334 2.99 0.902
51.0 0.775 6.46 48.3 271.0 0.336 2.98 0.901

50.0 0.780 6.51 48.7 273.0 0.338 2.96 0.901
49.0 0.784 6.54 48.9 275.0 0.340 2.94 0.900
48.0 0.788 6.57 49.2 276.0 0.341 2.93 0.900
47.0 0.793 6.61 49.5 278.0 0.343 2.92 0.899
46.0 0.797 6.65 49.8 279.0 0.345 2.90 0.898

45.0 0.802 6.69 50.0 281.0 0.348 2.87 0.898
44.0 0.806 6.72 50.3 282.0 0.349 2.87 0.897
43.0 0.811 6.76 50.6 284.0 0.351 2.85 0.897
42.0 0.816 6.81 50.9 286.0 03354 2.82 0.896
41.0 0.820 6.84 51.2 287.0 0.355 2.82 0.896

40.0 0.825 6.88 51.5 289.0 0.357 2.80 0.895
39.0 0.830 6.92 51.8 291.0 0.359 2.79 0.894
38.0 0.835 6.96 52.1 292.0 0.362 2.76 0.894
37.0 0.840 7.01 52.4 294.0 0.364 2.75 0.893
36.0 0.845 7.05 52.7 296.0 0.366 2.73 0.892

35.0 0.850 7.09 53.0 298.0 0.368 2.72 0.892
34.0 0.855 7.13 53.3 299.0 0.370 2.70 0.891
33.0 0.860 7.17 53.6 301.0 0.372 2.69 0.891
32.0 0.865 7.21 53.9 303.0 0.375 2.67 0.890
31.0 0.871 7.26 54.3 305.0 0.377 2.65 0.889

30.0 0.876 7.31 54.7 307.0 0.380 2.63 0.889
29.0 0.882 7.36 55.1 309.0 0.382 2.62 0.887
28.0 0.877 7.40 55.4 311.0 0.384 2.60 0.887
27.0 0.893 7.45 55.7 313.0 0.387 2.58 0.886
26.0 0.898 7.49 56.0 315.0 0.389 2.57 0.885

25.0 0.904 7.54 56.4 317.0 0.392 2.55 0.885
24.0 0.910 7.59 56.8 319.0 0.394 2.54 0.884
23.0 0.916 7.64 57.2 321.0 0.397 2.52 0.883
22.0 0.922 7.69 57.5 323.0 0.399 2.51 0.883
21.0 0.928 7.74 57.9 325.0 0.402 2.49 0.882

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 14

ENGINEERING TABLES

Gravity Correction Table (continued)
Weight (Density) Fluid Head
Gallon
Cubic
Foot
Barrel Pressure per Foot Height per Pound
Buoyancy
Factor

Degrees
API

Specific
Gravity
Pounds Lbs / Sq In Feet Totally Immersed
20.0 0.934 7.79 58.3 327.0 0.405 2.47 0.881
19.0 0.940 7.78 58.7 329.0 0.407 2.46 0.880
18.0 0.946 7.89 59.0 331.0 0.410 2.44 0.879
17.0 0.953 7.95 59.5 334.0 0.413 2.42 0.879
16.0 0.959 8.00 59.8 336.0 0.416 2.40 0.878

15.0 0.966 8.06 60.3 339.0 0.419 2.39 0.877
14.0 0.973 8.11 60.7 342.0 0.421 2.38 0.876
13.0 0.979 8.16 61.0 343.0 0.424 2.36 0.876
12.0 0.986 8.22 61.5 345.0 0.427 2.34 0.874
11.0 0.993 8.28 61.9 348.0 0.430 2.33 0.874

1.00 8.34 62.4 350.0 0.433 2.31 0.873
1.01 8.40 62.8 353.0 0.436 2.29 0.872
1.03 8.60 64.3 361.0 0.447 2.24 0.869
1.06 8.80 65.8 370.0 0.457 2.19 0.866
10.0
Degrees
API or
Pure
Water
1.08 9.00 67.3 378.0 0.468 2.14 0.862

1.10 9.20 68.8 386.0 0.478 2.09 0.860
1.13 9.40 70.3 395.0 0.488 2.05 0.856
1.15 9.60 71.8 403.0 0.499 2.00 0.853
1.154 9.625 72.0 404.0 0.500 2.00 0.853
1.18 9.80 73.3 412.0 0.509 1.96 0.850

1.20 10.0 74.8 420.0 0.519 1.93 0.847
1.22 10.2 76.3 428.0 0.530 1.89 0.844
1.25 10.4 77.8 437.0 0.540 1.85 0.841
1.27 10.6 79.3 445.0 0.551 1.81 0.838
1.29 10.8 80.8 454.0 0.561 1.78 0.835

1.32 11.0 82.3 462.0 0.571 1.75 0.832
1.34 11.2 83.8 470.0 0.582 1.72 0.829
1.37 11.4 85.3 479.0 0.592 1.69 0.826
1.39 11.6 86.8 487.0 0.603 1.66 0.823
1.41 11.8 88.3 496.0 0.613 1.63 0.820

1.44 12.0 89.8 504.0 0.623 1.61 0.817
1.46 12.2 91.3 512.0 0.634 1.58 0.814
1.49 12.4 92.8 521.0 0.644 1.55 0.810
1.51 12.6 94.3 529.0 0.655 1.53 0.808
1.53 12.8 95.8 538.0 0.665 1.50 0.804

1.56 13.0 97.2 546.0 0.675 1.48 0.801
1.58 13.2 98.7 554.0 0.686 1.46 0.798
1.61 13.4 100.0 563.0 0.696 1.44 0.795
1.63 13.6 102.0 571.0 0.706 1.42 0.792


Salt
Water
1.65 13.8 103.0 580.0 0.717 1.39 0.789

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 15
Copyright Wood Group ESP January 2000
ENGINEERING TABLES

Electrical Terms and Definitions
Term Definition Term Definition
AC Alternating Current Power Factor ratio of true to apparent power
Amperes unit of current or rate at flow of
electricity.
Watthour unit of electrical work; indicates
expenditure of electrical power of one
watt for one hour.
Volt unit of electromotive force Horsepower A measure of time rate of doing work;
equivalent to raising 33,000-lbs one ft.
in one minute. 1 hp = 746 watts
Ohm unit of resistance Torque Formulas:
Ohms Law for DC
Current
Ohms

Electromotive Force / Resistance
Volts / Amperes

N
HPx5252
T =

DC Direct Current Where: T = Torque (lb-ft)
HP = Horsepower
N = Speed (RPM)
Volt Amperes unit of apparent power T = F x R
Megohm 1,000,000 Ohms Where: F = Force (lbs)
R = Radius (ft)
Watt unit of true power
= volt amperes x power factor


To Find Formula Inflow Performance Relationships for
Solution Gas Drive Wells (Below Bubble Point)
Brake HP
Pump%Eff x 3960
SpGr HeadFeet x x GPM

2

Pr
Pwf
0.80
Pr
Pwf
0.20 1
Max Qo
Qo

=

Brake HP
Pump%Eff x 136,000
SpGr HeadFeet x x BPD

Pr Static Reservoir Pressure at
Producing Zone
HP Input
(Three Phase)
746
PF x 1.732 Volt x x Amp

Pwf Flowing Wellbore Pressure at
Producing Zone
Qo Production Rate at Pwf HP Input
(Three Phase)
KW x 1.34
Qo Max Production Rate at 100% Drawdown, Pwf = 0
Where HP = Horsepower; GPM = Gallons Per Minute; Sp Gr = Specific Gravity; Pump % Eff = Pump Percent Efficiency
BPD = Barrels Per Day; Amp = Amperes; Volt = Surface Voltage; PF = Power Factor; KW = Kilowatts

Formulas for Determining Kilowatts, KVA, Horsepower and Amperes
Alternating Current
Desired Data
Single Phase Three Phase
Kilowatts
1000
Pf x Amps x Volts

1000
Pf x Amps x Volts x 1.732

Kilovolt Ampere
1000
Amps x Volts

1000
Amps x Volts x 1.732

Horsepower (Output)
100 x 746
Pf x Eff x Amps x Volts

100 x 746
Pf x Eff x Amps x Volts x 1.732

Amperes (When HP is known)
HP x Eff x Volts
746 x HP

PF x Eff x Volts x 1.732
746 x HP

Amperes (When Kilowatts are known)
PF x Volts
1000 x Kilowatts

PF x Volts x 1.732
1000 x Kilowatts


Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 16
Abbreviations, Electrical Terms and Definitions
Term Definition Term Definition
AC Alternating Current
Amperes
(Amp) (A)
Unit of current or rate at flow of
electricity.

Ohms Law for DC
Current
Ohms

Electromotive Force / Resistance
Volts / Amperes
API American Petroleum Institute
P
B

Bubble Point Pressure
AR Abrasion Resistant PBTD Plug Back Total Depth
ASSY Assembly PIP Pump Intake Pressure
BEP Best Efficiency Point PMP Pump
BHT Bottom Hole Temperature Power Factor (PF) Ratio of true to apparent power
BO Bolt-On
P
R

Reservoir Pressure
BPD Barrels Per Day PSD Pump Setting Depth
Pump % Eff Pump Percent Efficiency Brake Horsepower
(BHP)
The net effective power of a prime
mover
P
WF

Producing Bottom Hole Pressure
BRG Bearing Q Volume Flow Rate
C
P

Wellhead Casing Pressure
Qmin Minimum volumetric flow rate
CONST Construction Qmax Maximum volumetric flow rate
CMP Compression Stage SHD Shroud
DC Direct Current Sp Gr Specific Gravity
DLS Dog Leg Severity SST Stainless Steel
STBPD Stock Tank Barrels Per Day Drift Guaranteed minimum inside
diameter of API tubulars STD Standard
EFF Efficiency STGS Stages
FLT Floater Stage STL Steel
FT Feet TA 338 Series Equipment
GLR Gas / Liquid Ratio 400 Series Equipment
GOR Gas / Oil Ratio
TD
Total Depth
GPM Gallons Per Minute TE 538 Series Equipment
GS Gas Separator
T
F

Tubing Friction Loss
TG 513 Series Equipment
TH 562 Series Equipment
Horsepower (HP) A measure of time rate of doing
work; equivalent to raising 33,000-
lbs one ft. in one minute. 1 hp =
746 watts
THD Motors rated for wellbore conditions
HL High Load TJ 675 Series Equipment
HIPR High Pressure TM 862 Series Equipment
HSG Housing TN 950 Series Equipment
HSS High Strength Shaft
T
P

Wellhead Tubing Pressure
Hz Hertz TVD True Vertical Depth
ID Inside Diameter Unit of electromotive force
KG Kilograms
Volt ( )
Surface Voltage
KW Kilowatts Volt Amperes Unit of apparent power
LBS Pounds
M Meters
Watt unit of true power
= volt amperes x power factor
MCF Thousand cubic feet
MD Measured Depth

Megohm 1,000,000 Ohms
Watt-hour Unit of electrical work; indicates
expenditure of electrical power of
one watt for one hour.
MMSCF Million cubic feet WC Water Cut
MTR Motor

Y
G
( SG
g
)
Gas Specific Gravity
NO Number
Y
O
( SG
o
)
Oil Specific Gravity
OD Outside Diameter
Y
W
( SG
w
)
Water Specific Gravity
Ohm Unit of resistance

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 17
Copyright Wood Group ESP January 2000
ENGINEERING TABLES

Electrical Terms and Definitions
Term Definition Term Definition
AC Alternating Current Power Factor ratio of true to apparent power
Amperes unit of current or rate at flow of
electricity.
Watthour unit of electrical work; indicates
expenditure of electrical power of one
watt for one hour.
Volt unit of electromotive force Horsepower A measure of time rate of doing work;
equivalent to raising 33,000-lbs one ft.
in one minute. 1 hp = 746 watts
Ohm unit of resistance Torque Formulas:
Ohms Law for DC
Current
Ohms

Electromotive Force / Resistance
Volts / Amperes

N
HPx5252
T =

DC Direct Current Where: T = Torque (lb-ft)
HP = Horsepower
N = Speed (RPM)
Volt Amperes unit of apparent power T = F x R
Megohm 1,000,000 Ohms Where: F = Force (lbs)
R = Radius (ft)
Watt unit of true power
= volt amperes x power factor


To Find Formula Inflow Performance Relationships for
Solution Gas Drive Wells (Below Bubble Point)
Brake HP
Pump%Eff x 3960
SpGr HeadFeet x x GPM

2

Pr
Pwf
0.80
Pr
Pwf
0.20 1
Max Qo
Qo

=

Brake HP
Pump%Eff x 136,000
SpGr HeadFeet x x BPD

Pr Static Reservoir Pressure at
Producing Zone
HP Input
(Three Phase)
746
PF x 1.732 Volt x x Amp

Pwf Flowing Wellbore Pressure at
Producing Zone
Qo Production Rate at Pwf HP Input
(Three Phase)
KW x 1.34
Qo Max Production Rate at 100% Drawdown, Pwf = 0
Where HP = Horsepower; GPM = Gallons Per Minute; Sp Gr = Specific Gravity; Pump % Eff = Pump Percent Efficiency
BPD = Barrels Per Day; Amp = Amperes; Volt = Surface Voltage; PF = Power Factor; KW = Kilowatts

Formulas for Determining Kilowatts, KVA, Horsepower and Amperes
Alternating Current
Desired Data
Single Phase Three Phase
Kilowatts
1000
Pf x Amps x Volts

1000
Pf x Amps x Volts x 1.732

Kilovolt Ampere
1000
Amps x Volts

1000
Amps x Volts x 1.732

Horsepower (Output)
100 x 746
Pf x Eff x Amps x Volts

100 x 746
Pf x Eff x Amps x Volts x 1.732

Amperes (When HP is known)
HP x Eff x Volts
746 x HP

PF x Eff x Volts x 1.732
746 x HP

Amperes (When Kilowatts are known)
PF x Volts
1000 x Kilowatts

PF x Volts x 1.732
1000 x Kilowatts


Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 18

Conversion Factors
MULTIPLY BY TO OBTAIN MULTIPLY BY TO OBTAIN
Length Weight
Feet 0.3048 Meters Kilograms 2.6792 Pounds (Troy)
Inches 25.4 Millimeters Tons (Long) 2722.22 Pounds (Troy)
Area Tons (Short) 2430.55 Pounds (Troy)
Square Inches 6.4516 Sq. Centimeters Tons (Metric) 1000 Kilograms
Volume Linear Weight
Cubic Feet 7.481 Gallons Kgs. / Meter 0.672 Pounds / Foot
0.02832 Cubic Meters Pounds / Foot 1.488 Kgs. / Meter
Cubic Inches 16.387 Cu. Centimeters Pressure
Barrels (US Pet.) 5.6146 Cubic Feet Atmospheres 14.7 Pounds / Sq. In.
42 Gallons (US Liq.) 101.32 Kilopascals
0.159 Cubic Meters 29.92 Inches of Mercury
Gallons (Imperial) 1.2009 Gallons (US Liq.) 760 Millimeters of Mercury
Gallons (US Liq.) 231 Cubic Inches Bar 14.5 Pounds / Sq. In.
128 Ounces (US Liq.) 100 Kilopascals
8 Pints (US Liq.) Kilograms / Sq. Cm. 14.22 Pounds / Sq. In.
4 Quarts (US Liq.) 98.07 Kilopascals
Cubic Meters 35.31 Cubic Feet Kilopascals 0.145 Pounds / Sq. In.
6.2898 Barrels (US Pet.) Pounds / Sq. In. 6.895 Kilopascals
Liters 1000 Cu. Centimeters Feet of Water 0.4335 Pounds / Sq. In.
0.001 Cubic Meters 2.989 Kilopascals
Tons (Metric) 36Crude 7.452 Barrels (US Pet.) Meters of Water 1.422 Pounds / Sq. In.
Volume Ratios 9.806 Kilopascals
Cu. Feet / Cu. Foot 5.615 Cu. Feet / Bbl. Density
Cu. Meters / Cu. Meter 5.615 Cu. Feet / Bbl. Pounds / Cu. Ft. 16.0184 Kgs. / Cu. Meter
Velocity Pounds / Cu. In. 27.68 Grams / Cu. Cm.
Feet / Second 0.3048 Meters / Second Pounds / Gallon 7.48 Pounds / Cu. Ft.
Feet / Minute 0.00508 Meters / Second Kgs. / Cu. Meter 0.06243 Pounds / Cu. Ft.
Meters / Second 3.2808 Feet / Second Cubic Feet of Water 62.43 Pounds of Water
Meters / Minute 0.05468 Feet / Second Productivity Index
Volumetric Flow Rate Bbls/Day / Atm 0.06805 Bbls/Day / PSI
Cubic Feet / Day 0.1781 Barrels / Day 0.001569 Cu. Meter/Day / KPa
0.2831 Cu. Meters / Day Bbls/Day / Bar 0.06895 Bbls/Day / PSI
Barrels / Minute 1440 Barrels / Day 0.00159 Cu. Meter/Day / KPa
228.9 Cu. Meters / Day Bbls/Day / Kg/Cm
2
0.07031 Bbls/Day / PSI
Barrels / Hour 24 Barrels / Day 0.001621 Cu. Meter/Day / KPa
3.816 Cu. Meters / Day Bbls/Day / KPa 6.895 Bbls/Day / PSI
Barrels / Day 0.159 Cu. Meters / Day 0.159 Cu. Meter/Day / KPa
Gallons / Minute 34.29 Barrels / Day Bbls/Day / PSI 0.02307 Cu. Meter/Day / KPa
5.451 Cu. Meters / Day Cu. Meter/Day / Atm. 0.4279 Bbls/Day / PSI
Cu. Meters / Hour 150.9 Barrels / Day 0.00987 Cu. Meter/Day / KPa
24 Cu. Meters / Day Cu. Meter/Day / Bar 0.4336 Bbls/Day / PSI
Cu. Meters / Day 6.289 Barrels / Day 0.01 Cu. Meter/Day / KPa
Temperature Cu. Meter/Day / PSI 6.289 Bbls/Day / PSI
Celsius + 17.78 1.8 Fahrenheit 0.145 Cu. Meter/Day / KPa
Celsius + 273 1 Kelvin Cu. Meter/Day / Kg/Cm
2
0.4422 Bbls/Day / PSI
Fahrenheit - 32 0.5555 Celsius 0.01019 Cu. Meter/Day / KPa
Fahrenheit + 460 1 Rankin Cu. Meter/Day / KPa 43.35 Bbls/Day / PSI
Torque Power
Foot-Pound 1.356 Newton-Meters Horsepower 0.7457 Kilowatts

Wood Group ESP, INC.
Product Catalog - Engineering Data - Copyright Wood Group ESP, INC. - October, 2009 Pg. 19

You might also like