You are on page 1of 4

ZAPATA EXCENTRICA

ZAPATA EXCENTRICA

T =

1.90

B=

0.95

t1

h=
t2
1.90

DATOS DE DISEO
CARGA MUERTA

( PD.)

40.52

CARGA VIVA

( PL.)

6.58

Tn.

2.10

gr/cm3.

PESO ESPECIFICO SUELO

(&)

COEFICIENTE DE EMPUJE

(Kc)

0.36

RESISTENCIA CONCRETO (f'c)


RESISTENCIA DEL SUELO (t)
SOBRE CARGA SUELO

(S/C)

Tn.

210.00

Kg/cm2.

3.00

Kg/cm2.

250.00

Kg/m2.

PROFUNDIDAD CIMENTACION (hf)

1.20

m.

MODULO RESISTENCIA CONCRETO (E)

217370.65

Kg/cm2.

4200.00

Kg/cm2.

FLUENCIA DEL ACERO

(fy)

DISEO
t hf*& - S/C

n =
n =

27.23

Tn/m2.

AREA ZAPATA
Az = Pt/n

1.72970988 m2.

b=

0.95

m.
m.

Usar medida Redondeada

1.90

m.

DIMENSION DE LA ZAPATA

0.95

Az = (2b)b

0.93

Usar medida Redondeada


T = Az/b

m.

1.82

1.90

ALTURA DE LA ZAPATA PARA CONSIDERARLA RIGIDA


hz > 2.3b[(Kob)/E]^1/3

0.41427557 m.

Usar
Altura de columna
Columna Primer Nivel
Predimensin Columna

h=

0.60

m.

Lc =
3.00
m.
t1xt2=1.25P/f'cn 1121.42857 cm2.
33.48773763

Usar

Comprobando

n = asumido

0.25

cm2.

35

35

n=

0.22886297

cm.

Peso propio de Columna

1.764

Comparando : Si el n comprobado es menor que el n asumido entonces la dimensin de la columna es correcta.


=Ekc/KoIz

0.003

S= hz/lc

0.20

D = -12EP/Az

0.093214191

=
< 10

0.13

EXCENTRICIDAD e=b-t1/2

0.300

CONFORME

DISEO POR FLEXION

0.35

0.6

a) Direccin de la Excentricidad
d = h-(1.5+7.5)
d=

Wnu = Pu/d
Mumax.=

52.305

cm.

70.97233684

Tn/m2.

12.77502063

Tn-m

d = 52.305

Area de acero
a = d/5

3.75
0.95

As=Mu/0.85fy(d-a/2)

15.1248284

Comprobando el valor asumido de a

cm.

a = asfy/.85f'cb

3.74609

3.75

AREA DE ACERO

As=Mu/0.85fy(d-a/2)
Asmin=0.0018bd

15.12
17.888

cm2.
cm2.

COMPARAR As CON Asmn. Y USAR EL QUE SEA MAYOR


USAMOS
USAR

cm2.

0.346

1/2"

1.27

1.27

5/8"

1.59

1.98

3/4"

1.91

2.85

3/4

6.00

S= T-2r-b/n-1

17.888

OK !
mm AREA

0.34618

3/4

USAR

0.78

0.35

b) Direccin Transversal
d = h-(7.5+T/2)
d=

Wnu = Pu/d
Mumax.=
Iv =

51.55

cm.

37.044

Tn/m2.

11.12477625

Tn-m

0.78

m.

a = d/5

2.88

Area de acero

As=Mu/0.85fy(d-a/2)

23.2903674

cm.

a = asfy/.85f'cb

Comprobando el valor asumido de a

1.90
2.88426

2.88

OK !

AREA DE ACERO
As=Mu/0.85fy(d-a/2)
Asmin=0.0018bd

23.29
17.63

cm2.
cm2.

COMPARAR As CON Asmn. Y USAR EL QUE SEA MAYOR

USAMOS
USAR
S= T-2r-b/n-1

8.00

23.29

cm2.

0.112

3/4

0.111557143
USAR

3/4

COLUMNA CONDICION DE DISEO ADICIONAL


CARGA ULTIMA
MOMENTO ULTIMO

Pu =1.4CM+1.7CV

Mu=Pue/1+s
K=Pu/f'cbt
e/t =
g=t2-(

70.3836

Tn.

10.7761417 Tn-m
0.2736
0.64

m.
%

7.896

cm2.

ACERO MINIMO Gmn = 1%

12.25

cm2.

COMPARANDO SE USA EL AREA MAYOR

12.25

cm2.

LUEGO EL AREA DE ACERO = g*t1*t2

0.857

AREA DE ACERO
W/ml. AREA

1/4

0.25

0.32

3/8

1.02

0.71

1/2

1.60

1.29

5/8

2.26

1.98

3/4"

2.26

2.85

4.04

5.07

Pgina 1

0.60

ZAPATA CENTRADA

ZAPATA CENTRADA

T =

0.95

30

t+d

0.95
S

30

d/2

0.95
b+d
DATOS DE DISEO
CARGA MUERTA

( PD.)

20

CARGA VIVA

( PL.)

8.50

Tn.

2.10

gr/cm3.

PESO ESPECIFICO SUELO

(&)

Tn.

COEFICIENTE DE EMPUJE

(Kc)

0.36

RESISTENCIA CONCRETO

(f'c)

210.00

Kg/cm2.

RESISTENCIA DEL SUELO

(t)

3.50

Kg/cm2.

(S/C)

500.00

Kg/m2.

(hf)

1.20

m.

217370.65

Kg/cm2.

4200.00

Kg/cm2.

SOBRE CARGA SUELO


PROFUNDIDAD CIMENTACION

MODULO RESISTENCIA CONCRETO (E)


FLUENCIA DEL ACERO

(fy)

DISEO
n =

t hf*& - S/C

n =

31.98

Az = Pt/n

0.891181989

m2.

T=

0.94

m.
m.
m.
m.

Tn/m2.

AREA ZAPATA
Iv1 = Iv2

0.95

Usar medida Redondeada


S=

0.94

0.95

Usar medida Redondeada

Verificando

Iv1 = Iv2

0.94

0.94

m2.

0.33
0.33

DIMENSION DE LA ZAPATA

0.95

REACCION NETA DEL TERRENO


Wnu = Pu/Azap

47.03601108

D41=D42

CONFORME

0.95

Tn/m2.

ALTURA DE LA ZAPATA PARA CONSIDERARLA RIGIDA


ASUMIR h

Usar

h=

CALCULAR dprom.= h-(7,5+b)

0.60

m.

50.59

cm.

VERIFICACION POR CORTANTE


Vdu = (Wnu*S)(Iv-d) =
Vn = Vdu/
-9.509851393
Vc=0.53f'c^0.5bd
COMPARANDO
Vc >Vn
Altura de columna

t1xt2=1.25P/f'cn

Predimensin Columna

26.04940361

Comprobando

Tn.
36.913

>

36.91252904

Lc =

Columna Primer Nivel


Usar

-8.083373684

3.00
678.5714286

-9.509851393

CONFORME

m.

n = asumido

cm2.

0.25

cm2.

30

30

n=

0.188492063

cm.

Peso propio de Columna

1.296

Comparando : Si el n comprobado es menor que el n asumido entonces la dimensin de la columna es correcta.


=Ekc/KoIz

0.003

S= hz/lc

0.20

D = -12EP/Az

0.122722393

=
< 10

0.13

EXCENTRICIDAD

e=b-t1/2

0.325

CONFORME

DISEO POR FLEXION


Mumax.=

2.36

Tn-m
0.95

Area de acero

Pgina 2

ZAPATA CENTRADA
a = d/5

0.32

As=Mu/0.85fy(d-a/2)

1.310791545

Comprobando el valor asumido de a

cm.

a = asfy/.85f'cb

0.95
0.324654253

0.32

OK !

AREA DE ACERO
As=Mu/0.85fy(d-a/2)
Asmin=0.0018bd

1.31
8.6509

cm2.
cm2.
AREA ACERO

COMPARAR As CON Asmn. Y USAR EL QUE SEA MAYOR

USAMOS
USAR
S= T-2r-b/n-1

8.65

cm2.

5/8

4.00
0.261376667

5/8

USAR

0.26137667

mm.

AREA

1/2

1.27

1.27

5/8

1.59

1.98

3/4

1.91

2.85

b) Direccin Transversal

Mumax.=
Iv =

2.359884868

Tn-m

0.33

m.
0.95

Area de acero
a = d/5

0.32

As=Mu/0.85fy(d-a/2)

1.310791545

Comprobando el valor asumido de a

cm.

a = asfy/.85f'cb

0.95
0.324654253

AREA DE ACERO

AREA ACERO

As=Mu/0.85fy(d-a/2)
Asmin=0.0018bd

1.31
8.6509

cm2.
cm2.

COMPARAR As CON Asmn. Y USAR EL QUE SEA MAYOR

USAMOS
USAR
S= T-2r-b/n-1

4.00

8.65

cm2.

0.26137667

5/8

0.261376667
USAR

5/8

COLUMNA CONDICION DE DISEO ADICIONAL


CARGA ULTIMA Pu =1.4CM+1.7CV
MOMENTO ULTIMO Mu=Pue/1+s

K=Pu/f'cbt
e/t =
g=t2-(
LUEGO EL AREA DE ACERO = g*t1*t2

44.2644
6.777139108

Tn.
Tn-m

0.234203175
0.59

m.
%

0.342
5.268

cm2.

ACERO MINIMO Gmn = 1%

9.00

cm2.

COMPARANDO SE USA EL AREA MAYOR

9.00

cm2.

Pgina 3

mm.

AREA

1/2

1.27

1.27

5/8

1.59

1.98

3/4

1.91

2.85

ZAPATA CENTRADA

h=

0.60

Pgina 4