D103411X012 April 2012

Field Communicator Menu Tree - DVC6200 Digital Valve Controller


www.Fisher.com
FIELDVUE DVC6200 Digital Valve Controller
Menu Tree applies to:
Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process
Management business unit of Emerson Electric Co. Emerson, Emerson Process Management,
and the Emerson logo are trademarks and service marks of Emerson Electric Co. HART is a
mark owned by the HART Communication Foundation. All other marks are the property of
their respective owners.
Instrument Level HC, AD, PD, and ODV
Device Revision DDRevision Firmware Revision
2 7, 9, & 10 7
Hot Key
1Instrument Mode
2Control Mode
3Protection
4Stabilize/Optimize
Online
1Configure
2Service Tools
3Overview
Calibrate
1Travel Calibration
2Sensor Calibration
3Relay
4Restore Factory
5PST Calibration
Configure
1Guided Setup
2Detailed Setup
3Calibrate
HART Applications
1Offline
2Online
3Utility
4HART Diagnostics
1
Service Tools
1Alert Conditions
2Status
3Device Record
4Stroke Valve
5Partial Stroke Test
Overview
1Analog In
2Setpoint
3Travel
4Drive Signal
5Pressure
6Variables
7Device Information
8DDInformation
1
13
3
2
35
3
Guided Setup
1Setup Wizard
2Performance Tuner
2Stabilize/Optimize
11
Detailed Setup
1Mode/Protection
2Response Control
3Alert Setup
4Status
5Instrument
6Valve and Actuator
7SIS/Partial Stroke
12
3
SIS/Partial Stroke
1PST Enable
2PST Enable
3View/Edit PST Variables
127
4
1
2
3
4
5
Notes:
111 indicates fastkey sequence to reach menu
This menu is available by pressing the left
arrow key from the previous menu
Instrument level AD, PD, and ODV only
Instrument level ODV only
Instrument level HC, AD, and PDonly
Instrument level HC only
Device Information
1HART Tag
2Device ID
3Manufacturer
4Model
5Device Revision
6Firmware Revision
7Hardware Revision
8Instrument Level
9HART Universal Revision
Pressure
1Pressure A
2Pressure B
3A minus B
4Supply
37
Variables
1Auxiliary Input
2Temperature
3Maximum Recorded Temperature
4Minimum Recorded Temperature
5Cycle Counter
6Travel Accumulator
7RawTravel Input
8ViewNumber of Days Powered Up
9Number of Power Ups
36
2
23
Valve &Actuator
1Manufacturer
2Valve Serial Number
3Valve Style
4Actuator Style
5Travel Sensor Motion
6View/Edit Feedback
Connection
7Assembly Specification Sheet
126
2
121
Mode/Protection
1Instrument Mode
2Control Mode
3Restart Control Mode
4Burst Mode
5Protection
122
Travel Calibration
1Auto Calibration
2Manual Calibration
131
132 Sensor Calibration
1Pressure Sensors
2Travel Sensor
3Analog In
Alert Setup
1Electronics Alerts
2Sensor Alerts
3Environment Alerts
4Travel Alerts
5Travel History Alerts
6SIS Alerts
6Alert Record
Response Control
1Tuning
2Travel/Pressure Control
3Input Characterization
4CustomCharacterization Table
5Dynamic Response
Burst Mode
1Burst Enable
2Change Burst Enable
3Burst Command
4Change Burst Command
5Cmd 3 Configured Pressure
Tuning
1Travel Tuning
2Integral Settings
3Pressure Tuning
Travel/Pressure Control
1Travel/Pressure Select
2Cutoffs and Limits
3Pressure Control
4End Point Pressure Control
Dynamic Response
1SP Rate Open
2SP Rate Close
3View/Edit Lag Time
3View/Edit Lead/Lag
124
1214
1221
1222
1259
Units
1Pressure Units
2Temperature Units
3Analog In Units
Analog Input Range
1Input Range Hi
2Input Range Lo
Calib Status and Type
1Last AutoCal Status
2Last Calibration Type
General
1HART Tag
2Message
3Descriptor
4Date
5Valve Serial Number
6Instrument Serial Number
7Polling Address
Instrument
1General
2Units
3Analog Input Range
4Relay Type
5Zero Power Condition
6Maximum Supply Pressure
7Auxiliary Terminal Action
8Instrument Date and Time
9Calib Status and Type
125 1251
1252
1253
Status
1Instrument Time
2Calibration and Diagnostics
3Operational
4Integrator Saturation
1225
Travel Tuning
1Travel Tuning Set
2Integral Enable
3Integral Gain
4Stabilize/Optimize
4Performance Tuner
Integral Settings
1Integral Dead Zone
2Integral Limit
Pressure Tuning
1Pressure Tuning Set
2Integral Enable
3Integral Gain
Cutoffs and Limits
1Cutoff Hi
2Cutoff Lo
3Change Cutoffs
4Travel Limit Hi
5Travel Limit Lo
6Change Travel Limits
Pressure Control
1Pressure Range Hi
2Pressure Range Lo
12211
12222
End Point Pressure Control
1End Pt Control Enab
2PST Start Point
3EPPC Setup Point
4EPPS Saturation Time
12212
12213
12223
12224
Integrator Saturation
1Integrator Sat Hi Enable
2Integrator Sat Lo Enable
3Integral Limit
4Integral Dead Zone
Instrument Time
1Inst Time Invalid Enable
2Instrument Date and Time
1241
1244
Operational
1Pressure Control Active Enable
2MultiDrop Enable
Calibration and Diagnostics
1Calibration in Progress Enable
2Autocal in Progress Enable
3Diagnostic in Progress Enable
4Diagnostic Data Avail Enable
Electronics Alerts
1Drive Current Shutdown
2Drive Signal Alert
3Processor Impaired Alerts
Drive Signal Alert
1Drive Signal Alert Enable
2Drive Signal
Processor Impaired Alerts
1Offline/Failed Alert Enable
2LowPower Write Fail Enable
3NonCritical NVMAlert Enable
4Critical NVM Shutdown
5Flash ROMShutdown
6No Free Time Shutdown
7Reference Voltage Shutdown
REVERSE
1243
1242
1231
12312
12313
5
SIDE
2
6Fast key sequence for Alert Record with
instrument level ODV is 1237
6
3
E 2010, 2012 Fisher Controls International LLC. All rights reserved.
3
475 Field
Communicator
ON
123
Hardware Revision
1
3
3
2
Device Record
1Maximum Recorded Temperature
2Minimum Recorded Temperature
3ViewNumber of Days Powered Up
4Number of Power Ups
3
4
3
www.FIELDVUE.com
For the telephone number of the Emerson Process
Management sales office nearest you, contact:
In North America
Fisher Controls International LLC
1 (641) 7543011
In Latin America
Fisher Controls International LLC
1 (314) 7469900
In Asia Pacific
Emerson Process Management
Asia Pacific Private Ltd.
(65) 67778211
In Europe
Emerson Process Management Ltd.
+44 1634 895800
For equipment service or support needs, contact
your local Emerson Process Management sales office.
Function/Variable FastKeySequence
Actuator Style 1264
Alert Conditions 21
Alert Record
1236
1237
Analog Input 31
Analog Input Range 1253
Analog Input Units 12523
Auxiliary Input 361
Auxiliary Terminal Action 1257
Burst Mode 1214
Calibrate 13
Calibration and Diagnostics (Status) 1242
Calibration Status and Type 1259
Control Mode
Hot Key2
1212
Cycle Counter 365
CustomCharacterization Table 1224
Cutoffs and Limits 12222
Date 12514
Descriptor 12513
Device Description (DD) Information 38
Device ID 372
Device Revision 375
Drive Signal 34
Electronics Alerts 1231
End Point Pressure Control
(3)
12224
Environment Alerts 1233
Feedback Connection, View/Edit 1266
Firmware Revision 376
Hardware Revision 377
HART Tag
12511
371
HART Universal Revision 379
Input Characterization 1223
Instrument Date and Time 1258
Instrument Level 378
Function/Variable FastKey Sequence
Instrument Mode
Hot Key1
1211
Instrument Serial Number 12516
Instrument Time (Status) 1241
Integrator Saturation (Status) 1244
Integral Settings 12212
Lag Time, View/Edit
(4)
12253
Lead/Lag, View/Edit
(3)
12253
Manufacturer (Valve & Actuator) 1261
Manufacturer (Device Information) 373
MaximumSupply Pressure 1256
Message 12512
Model (Device Information) 374
Number of Power Ups
234
369
Operational (Status) 1243
Partial Stroke Test
(3)
25
Partial Stroke Test Enable
(3)
1271
Partial Stroke Test Variables, View/Edit
(3)
1273
Performance Tuner
(2)
112
Polling Address 12517
Pressure 35
Pressure Control 12223
Pressure Tuning 12213
Pressure Units 12521
Protection
Hot Key3
1215
PST Calibration
(3)
1-3-5
RawTravel Input 367
Relay (Calibration) 133
Relay Type 1254
Restart Control Mode 1213
Restore Factory Settings (Calibrate) 134
Sensor Alerts 1232
Sensor Calibration 132
Function/Variable FastKey Sequence
Set Point Rate Close 12252
Set Point Rate Open 12251
Setup Wizard 111
SIS Alerts
(3)
1236
Stabilize/Optimize
Hot Key4
112
(5)
Status 22
Stroke Valve 24
Temperature 362
Temperature, MaximumRecorded
231
363
Temperature, MinimumRecorded
232
364
Temperature Units 12522
Travel 33
Travel Accumulator 366
Travel Alerts 1234
Travel Calibration 131
Travel History Alerts 1235
Travel Sensor Motion 1265
Travel Set Point 32
Travel Tuning 12211
Travel/Pressure Select 12221
Valve Serial Number
12515
1262
Valve Style 1263
ViewNumber of Days Powered Up
233
368
Zero Power Condition 1255
NOTE: Italicized FastKey Sequence indicates fastkey sequence is applicable
only for instrument level ODV.
2. Instrument level AD, PD, and ODV only.
3. Instrument level ODV only.
4. Instrument level HC, AD, and PDonly.
5. Instrument level HC only.
Sensor Alerts
1Travel Sensor Shutdown
2Temp Sensor Shutdown
3Pressure Sensor Shutdown
Enviroment Alerts
1Auxilary Terminal Alert
2Supply Pressure Lo Alert
3Loop Current Validation
Enable
Travel Limit Alerts
1Travel Alert Hi Hi Enable
2Travel Alert Lo Lo Enable
3Travel Alert Hi Hi Point
4Travel Alert Lo Lo Point
Travel Alerts
1Travel
2Setpoint
3Travel Alert DB
4Travel Deviation Alert
5Travel Limit Alerts
6Travel Limit Hi/Lo Alerts
7Travel Limit/Cutoff Alerts
Travel History Alerts
1Cycle Counter
2Cycle Count/Travel
Accumulator Deadband
3Travel Accumulator
Travel Limit Hi/Lo Alerts
1Travel Alert Hi Enable
2Travel Alert Lo Enable
3Travel Alert Hi Point
4Travel Alert Lo Point
Travel Limit/Cutoff Alerts
1Travel Limit/Cutoff Hi Enable
2Travel Limit/Cutoff Lo Enable
3Cutoff Hi
4Cutoff Lo
5Change Cutoffs
6Travel Limit Hi
7Travel Limit Lo
8Change Travel Limits
Travel Deviation Alert
1Travel Deviation Alert Enable
2Travel Deviation Alert Point
3Travel Deviation Time
Travel Accumulator
1Travel Accumulator Alert Enable
2Travel Accumulator
3Travel Accumulator Alert Point
Cycle Counter
1Cycle Counter Alert Enable
2Cycle Counter
3Cycle Count Alert Point
SIS Alerts
1PST Pressure Limit
2Pressure Deviation Alert Enable
3Pressure Deviation Alert Point
4Pressure Deviation Time
ODV
HC, AD, PD
Supply Press Lo Alert
1Supply Pressure Lo Alrt Enable
2Supply
3Supply Pressure Lo Alert Point
Auxiliary Terminal Alert
1Auxiliary Terminal Alert Enable
2Auxiliary Input
3Auxiliary Terminal Action
12331
Alert Groups
1Failure Group Enable
2Valve Group Enable
3Miscellaneous Group
Enable
1234
1236
1232
1233
1235
12365
12375
12332
12351
12352
12353
ODV
12344
12345
12346
12347
Alert Setup
1Electronics Alerts
2Sensor Alerts
3Environment Alerts
4Travel Alerts
5Travel History Alerts
6SIS Alerts
6Alert Record
Alert Record
1Alert Record has
Entries Enable
2Alert Record Full Enable
3ViewAlert Records
4Clear ALL Records
5Alert Groups
ODV
HC, AD, PD
1236
1237
Cycle Count/Travel
Accumulator Deadband
1Deadband
123
3
Instrument level ODV only
3
6
6
Fast key sequence for Alert Record with
instrument level ODV is 1237
ALERT
SETUP
3