DISEO DE ESCALERA 2 tramo

DATOS
P:paso
CP:contra paso
t:espesor del cuello
B:Ancho de la ecalera
L: Lon. de esc.
L
1
: Lon. de esc. Descanso
2400 kg/cm
P = 0.3 m
CP = 0.165 m
t = 0.17 m
B= 1.5 m
COS()= 0.876
L= 2.7 M
L
1
=
3.35 M
S/C= 400 kg/m
S/C=acab. 100 kg/m
recub.= 4 cm
F'c= 175 kg/m
fy=. 4200 kg/m
1)METRADO DE CARGAS
a). Descanso
carga muerta
peso propio= CpxBx= 594
Acabados= BxS/Cacab=. 150
WD = 744 Kg/m
Sobrecarga = S/CxB=
WL= 600 Kg/m
CARGA ULTIMA Wu=1.5xWd+1.8xWL
Wu= 2061.6 Kg/m
Cp=0.18m
P=0.30m
t=L/20 L/25
Cp=0.18m
P=0.30m
t=L/20 L/25
b). Tramo inclinado
peso propio= 2.4 b (Cp/2+ t/cos)
peso propio= 995.46 Kg/m 995.46 Kg/m
Acabados= Bx S/C acab=. 150 Kg/m
WD = 1145.46 Kg/m
Sobrecarga S/C=BX400
WL= 600 Kg/m
CARGA ULTIMA Wu=1.5xWd+1.8xWL
Wu= 2623.6 Kg/m
2)ESQUEMA ESTRUCTURAL
Estado de cargas
M
1
=1/16 a 1/12 WL
2
M
1
= 1195.3965
M
2
=1/10 WL
2
M
2
= 1912.6344
L=2.70m
L2=3.32 m
WL
Wddes
L=2.70m L2=3.32m
M
1
M
2
M
4
M
3 M
5
M
1
M
2
M
4
M
3
M
5
M
3
=1/9 W((L
1
+L
2
)/2)
2
M
3
= 1707.7704
M
4
=1/10 WL
2
2
M
4
= 2313.6306
M
5
=1/16 a 1/12 WL
2
2
M
5
= 1928.0255
como es hiperesttico clculamos los momentos
Momento (+)= 1.93 tn-m
Momento (-)= 2.31 tn-m
Momento (-)= 1.7 tn-m
Clculo del peralte
d=t-(recub--/2)
1.29 cm
d= 12.355 cm
CALCULO DEL AREA DE ACERO (-)
Mu=Kuxbxd
Ku= 10.0887
En la tabla Ku vs para f'c=175kg/cm
= 0.0028
As = rBd/100
As = 5.1891 cm
Verificacin de acero minimo
As
min
= 0.0018 Bd
Asmin = 2.2239 cm
As dis = 5.1891 cm
refuerzo longitudinal
3/8"= 0.71 cm2
Smax<=45cm 3t 1/2"= 1.29 cm2
5/8"= 2 cm2
3/4"= 2.84 cm2
Alternativa 1 USAR 3/8" @ 14 cm n de varillas 7
Alternativa 2 USAR 1/2" @ 25 cm n de varillas 5
Alternativa 3 USAR 5/8" @ 39 cm n de varillas 3
Alternativa 4 USAR 3/4" @ 45 cm n de varillas 2
USAR ALTERNATIVA N1 USAR 1/2" @25cm 5.00varillas
considerando 5/8=
Astemp. =0.0018xbxt
Astemp. = 2.2239
3/8 =0.71 cm
Alternativa 1 USAR 3/8" @ 32 cm n de varillas 4
una sola capa
CALCULO DEL AREA DE ACERO (+)
Mu=Kuxbxd
Ku= 8.4291
En la tabla Ku vs para f'c=175kg/cm
= 0.0024
As = rBd/100
As = 4.4478 cm
Verificacin de acero minimo
As
min
= 0.0018 Bd
Asmin = 2.2239 cm
As dis = 4.4478 cm
refuerzo longitudinal
3/8"= 0.71 cm2
Smax<=45cm 3t 1/2"= 1.29 cm2
5/8"= 2 cm2
3/4"= 2.84 cm2
Alternativa 1 USAR 3/8" @ 16 cm n de varillas 6
Alternativa 2 USAR 1/2" @ 29 cm n de varillas 4
Alternativa 3 USAR 5/8" @ 45 cm n de varillas 2
Alternativa 4 USAR 3/4" @ 45 cm n de varillas 2
USAR ALTERNATIVA N1 USAR 1/2" @25cm 4.00varillas
Astemp. =0.0018xbxt
Astemp. = 2.2239
3/8 =0.71 cm
Alternativa 1 USAR 3/8" @ 32 cm n de varillas 4
una sola capa USAR 3/8" @30cm
VERIFICACION POR CORTE (ms crtico)
V =WuL/2-l(Ma+Mb)/L
V = 2.056730411 TN
M+WuxX/2-V=0
X= 0.80000
Ld=x+d= 0.92355
CHEQUEO POR CORTE
Vc=0.53xf'cxdxb
Vc= 12993.58234 tn okey
Wu
W
WA
x Wu
W
WA
x
18-20
13-15
15-17.5
Escalera en locales comerciales 18cm
B(m)
1
0.7
0.6
_Edif. De ofocinas 1.2
1.3
S/C (kg/m)
200
_Viviendas y edif. residenciales250-300
_Edif. Pblicos 400
_Edif. De ofocinas y tribunas 500
100
TIPO DE EDIF.
_Viviendas y edif. Comerciales
_Acabados
_Auxiliares o de servicio
_Caracol
_locales comerciales
SOBRECARGAS RNC
Escaleras en edificios
B ANCHO MINIMOS
TIPO DE EDIF.
_Viviendas
CONTRA PASOS MINIMOS
Escaleras secundaria
Escaleras monumentales
DISEO DE ESCALERA 1 tramo
DATOS
P:paso
CP:contra paso
t:espesor del cuello
B:Ancho de la ecalera
L: Lon. de esc.
L
1
: Lon. de esc. Descanso
2400 kg/cm
P = 0.3 m
CP = 0.165 m
t = 0.17 m
B= 1.5 m
COS()= 0.876
L= 3.9 M
L
1
=
1.5 M
S/C= 400 kg/m
S/C=acab. 100 kg/m
recub.= 4 cm
F'c= 175 kg/m
fy=. 4200 kg/m
1)METRADO DE CARGAS
a). Descanso
carga muerta
peso propio= CpxBx= 594
Acabados= BxS/Cacab=. 150
WD = 744 Kg/m
Sobrecarga = S/CxB=
WL= 600 Kg/m
CARGA ULTIMA Wu=1.5xWd+1.8xWL
Wu= 2061.6 Kg/m
Cp=0.18m
P=0.30m
t=L/20 L/25
b). Tramo inclinado
peso propio= 2.4 b (Cp/2+ t/cos)
peso propio= 995.46 Kg/m 995.46 Kg/m
Acabados= Bx S/C acab=. 150 Kg/m
WD = 1145.46 Kg/m
Sobrecarga S/C=BX400
WL= 600 Kg/m
CARGA ULTIMA Wu=1.5xWd+1.8xWL
Wu= 2623.6 Kg/m
2)ESQUEMA ESTRUCTURAL
Estado de cargas
M
1
=1/16 a 1/12 WL
2
M
1
= 2494.1
M
2
=1/10 WL
2
M
2
= 3990.56
M
3
=1/9 W((L
1
+L
2
)/2)
2
M
3
= 3563.13
M
4
=1/10 WL
2
2
M
4
= 463.86
M
5
=1/16 a 1/12 WL
2
2
M
5
= 386.55
como es hiperesttico clculamos los momentos
Momento (+)= 2.49 tn-m
Momento (-)= 3.99 tn-m
L=3.90m L2=1.50m
WL
Wddes
L=3.90m L2=1.50m
M
1
M
2
M
4
M
3
M
5
Momento (-)= 1.7 tn-m
Clculo del peralte
d=t-(recub--/2)
1.29 cm
d= 12.355 cm
CALCULO DEL AREA DE ACERO (-)
Mu=Kuxbxd
Ku= 17.4259
En la tabla Ku vs para f'c=175kg/cm
= 0.005
As = rBd/100
As = 9.26625 cm
Verificacin de acero minimo
As
min
= 0.0018 Bd
Asmin = 2.2239 cm
As dis = 9.26625 cm
refuerzo longitudinal
3/8"= 0.71 cm2
Smax<=45cm 3t 1/2"= 1.29 cm2
5/8"= 2 cm2
3/4"= 2.84 cm2
Alternativa 1 USAR 3/8" @ 8 cm n de varillas 13
Alternativa 2 USAR 1/2" @ 14 cm n de varillas 8
Alternativa 3 USAR 5/8" @ 22 cm n de varillas 5
Alternativa 4 USAR 3/4" @ 31 cm n de varillas 3
USAR ALTERNATIVA N1 USAR 1/2" @14cm 8.00varillas
Astemp. =0.0018xbxt
Astemp. = 2.2239
3/8 =0.71 cm
Alternativa 1 USAR 3/8" @ 32 cm n de varillas 4
una sola capa
CALCULO DEL AREA DE ACERO (+)
Mu=Kuxbxd
Ku= 10.8748
En la tabla Ku vs para f'c=175kg/cm
= 0.003
considerando 5/8=
As = rBd/100
As = 5.55975 cm
Verificacin de acero minimo
As
min
= 0.0018 Bd
Asmin = 2.2239 cm
As dis = 5.55975 cm
refuerzo longitudinal
3/8"= 0.71 cm2
Smax<=45cm 3t 1/2"= 1.29 cm2
5/8"= 2 cm2
3/4"= 2.84 cm2
Alternativa 1 USAR 3/8" @ 13 cm n de varillas 8
Alternativa 2 USAR 1/2" @ 23 cm n de varillas 5
Alternativa 3 USAR 5/8" @ 36 cm n de varillas 3
Alternativa 4 USAR 3/4" @ 45 cm n de varillas 2
USAR ALTERNATIVA N1 USAR 1/2" @13cm 5.00varillas
Astemp. =0.0018xbxt
Astemp. = 2.2239
3/8 =0.71 cm
Alternativa 1 USAR 3/8" @ 32 cm n de varillas 4
una sola capa USAR 3/8" @30cm
VERIFICACION POR CORTE (ms crtico)
V =WuL/2-l(Ma+Mb)/L
V = 3.65712595 TN
M+WuxX/2-V=0
X= 0.80000
Ld=x+d= 0.92355
CHEQUEO POR CORTE
Vc=0.53xf'cxdxb
Vc= 12993.5823 tn okey
Wu
WB
WA
x
18-20
13-15
15-17.5
Escalera en locales comerciales18cm
B(m)
1
0.7
0.6
_Edif. De ofocinas 1.2
1.3
S/C (kg/m)
200
_Viviendas y edif. residenciales250-300
_Edif. Pblicos 400
_Edif. De ofocinas y tribunas 500
100 _Acabados
B ANCHO MINIMOS
TIPO DE EDIF.
_Viviendas
_Auxiliares o de servicio
_Caracol
_locales comerciales
CONTRA PASOS MINIMOS
Escaleras secundaria
Escaleras monumentales
TIPO DE EDIF.
SOBRECARGAS RNC
_Viviendas y edif. Comerciales
Escaleras en edificios
DATOS
P:paso
CP:contra paso
t:espesor del cuello
B:Ancho de la ecalera
L: Lon. de esc.
L
1
: Lon. de esc. Descanso
2400 kg/cm
P = 0.1 m
P' = 0.1929378
CP = 0.165 m
t = 0.17 m
t
1
= 0.3279943 m
TM= 0.3289971
B= 1.5 m
COS()= 0.518
Li= 3
S/C= 500 kg/m
S/C=acab. 100 kg/m
recub.= 4 cm
F'c= 210 kg/m
fy=. 4200 kg/m
1)METRADO DE CARGAS
b). Tramo inclinado
peso propio= tmx 2.4
peso propio= 789.59 Kg/m 789.59 Kg/m
Acabados= Bx S/C acab=. 100 Kg/m
WD = 889.59
Kg/m
Sobrecarga S/C=BX400
WL= 500
Kg/m
CARGA ULTIMA Wu=1.5xWd+1.8xWL
DISEO DE ESCALERA APOYADA TRANSVERSALMENTE
Cp=0.16m
P=0.30m
t=ASUMIDO
B=1.25
P'=P/COS
Wu= 2412.3 Kg/m
W'u= 648.0 Kg/m
W'u x paso= 125.0 Kg/m
2)ESQUEMA ESTRUCTURAL
Momento (+)=W'ux L/8= 35.164787 Kg-m
Momento (-)=W'ux L/24= 11.721596 Kg-m
como es hiperesttico clculamos los momentos
Momento (+)= 0.0351648 tn-m
Momento (-)= 0.0117216 tn-m
Se disea como viga triangular con la carga perpendicular a la inclinacion de la esc.
CALCULO DEL PERALTE d
h'=P+t
1 h'= 10.3660343
h= 10.3660343
d= 7 cm
CALCULO DEL AREA DE ACERO (-)
Mu=Kuxbxd
Ku= 2.3922
En la tabla Ku vs para f'c=175kg/cm
= 0.002
As = rBd/100
As = 2.1 cm

L=1.55m
Wu=
Mmax
Verificacin de acero minimo
As
min
= 0.0018 Bd
Asmin = 0.126 cm
As dis = 2.1 cm
refuerzo transversal
3/8"= 0.71 cm2
Smax<=45cm 3t 1/2"= 1.29 cm2
5/8"= 2 cm2
3/4"= 2.84 cm2
Alternativa 1 USAR 3/8" @ 30 cm n de varillas 3
Alternativa 2 USAR 1/2" @ 30 cm n de varillas 2
USAR ALTERNATIVA N1 USAR 3/8" @30cm 3.00varillas
refuerzo longitudinal
Astemp. =0.0018xbxt
Astemp. = 1.26
3/8 =0.71 cm
Alternativa 1 USAR 3/8" @ 45 cm n de varillas 3
una sola capa
CALCULO DEL AREA DE ACERO (+)
Mu=Kuxbxd
Ku= 3.7196
En la tabla Ku vs para f'c=175kg/cm
= 0.0005
As = rBd/100
As = 0.525 cm
Verificacin de acero minimo
As
min
= 0.0018 Bd
Asmin = 0.243101645 cm
As dis = 0.525 cm
refuerzo transversal
3/8"= 0.71 cm2
Smax<=45cm 3t 1/2"= 1.29 cm2
5/8"= 2 cm2
3/4"= 2.84 cm2
Alternativa 1 USAR 3/8" @ 45 cm n de varillas 4
Alternativa 2 USAR 1/2" @ 45 cm n de varillas 3
VERIFICACION POR CORTE (ms crtico)
V =WuL/2-l(Ma+Mb)/L
V = 3.60283371 TN
M+WuxX/2-V=0
X= 1.72549
Ld=x+d= 1.79549248
CHEQUEO POR CORTE
Vc=0.53xf'cxdxb
Vc= 1.03729172 tn poner estribo
Wu
W
WA
x
MEDIDAS SEGN REGLAMENTO
18-20
13-15
15-17.5
Escalera en locales comerciales 18cm
B(m)
1
0.7
0.6
_Edif. De ofocinas 1.2
1.3
S/C (kg/m)
200
_Viviendas y edif. residenciales250-300
_Edif. Pblicos 400
_Edif. De ofocinas y tribunas 500
SOBRECARGAS RNC
TIPO DE EDIF.
_Viviendas y edif. Comerciales
_Viviendas
_Auxiliares o de servicio
_Caracol
_locales comerciales
Escaleras monumentales
Escaleras en edificios
B ANCHO MINIMOS
TIPO DE EDIF.
DISEO DE ESCALERA APOYADA TRANSVERSALMENTE
CONTRA PASOS MINIMOS
Escaleras secundaria

You might also like