You are on page 1of 6

PLC CUTTING MECHINE

• Notes :
LS = Limit Switch.
LS 1 = Limit Switch for Cutter Reverse.
LS 2 = Limit Switch for Cutter
Forward.
LS 3 = Limit Switch for Clamp1 (Fixed)
Forward (Clamp).
LS 4 = Limit Switch for Clamp1 (Fixed)
Reverse (UnClamp).
LS 5 = Limit Switch for Clamp2
(Movable) Forward (Clamp).
LS 6 = Limit Switch for Clamp2
(Movable) Reverse (UnClamp).
LS 7 = Limit Switch for Clamp2
(Movable) Forward.
LS 8 = Limit Switch for Clamp2
(Movable) Reverse.
• Number Of Inputs and Output PLC applied • Sequence PLC Programming for Cutting
: Machines :
1. Number Of Inputs PLC is 11 Input :
--- 1 Unit Input for Push Button Start. Step 1 :
--- 1 Unit Input for Push Button Emg / a. If Push Button Emg = OFF Then All
Emergency. System OFF.
--- 1 Unit Input for Selector Switch Electric b. If LS 1 = ON And LS 4 = ON And LS 6 =
Motor ON. ON And LS 8 = ON Then All Limit Switch
--- 8 Unit Input for Limit Switch (LS). Origin = ON.
--- Total Number Of Inputs PLC is c. If Push Button Emg = ON And Selector
Minimum 11 Input Unit. Switch Motor = ( OFF to ON ) And All Limit
Switch Origin = ON Then Contactor Motor
2. Number Of Output PLC is 9 Output : = ON.
--- 1 Unit Output for Contactor. It's
Functions to electrical Motor Cutter ( ON / Step 2 :
OFF Motor ) . a. If Push Button Start = ON And Contactor
--- 2 Unit Output for Solenoid Cylinder Motor = ON And All Limit Switch Origin =
Cutter : Forward - Reverse. ON Then Starts Automatic Cutting Process.
--- 2 Unit Output for Solenoid Cylinder
Clamp1 : Clamp - UnClamp .
--- 2 Unit Output for Solenoid Cylinder b. If have been three times ( Data Setting =
Clamp2 : Clamp - UnClamp. 3 (Can be Changed) ) Then Stops
--- 2 Unit Output for Solenoid Cylinder Automatic Cutting Process And ALL Return
Clamp2 : Forward - Reverse. Origin.
--- Total Number Of Outputs PLC is c. If Push Button Emg = Pulse ON Then ALL
Minimum 9 Output Unit. Return Origin.
• INPUT PLC : • OUTPUT PLC :
000.00 ; Push Button Start 005.00 ; Contactor Motor Cutter
000.01 ; Push Button Emergency
005.01 ; Solenoid for Cylinder
000.02 ; Selector Switch Motor ON / OFF
000.03 ; LS or Limit Switch Cutter REV
Cutter Forward
( Reverse) 005.02 ; Solenoid for Cylinder
000.04 ; LS or Limit Switch Cutter FWD Cutter Reverse
( Forward ) 005.03 ; Solenoid for Cylinder
000.05 ; LS or Limit Switch Clamp1 Clamp1 CLAMP
CLAMP 005.04 ; Solenoid for Cylinder
000.06 ; LS or Limit Switch Clamp1
Clamp1 UNCLAMP
UNCLAMP
000.07 ; LS or Limit Switch Clamp1 005.05 ; Solenoid for Cylinder
CLAMP Clamp2 CLAMP
000.08 ; LS or Limit Switch Clamp1 005.06 ; Solenoid for Cylinder
UNCLAMP Clamp2 UNCLAMP
000.09 ; LS or Limit Switch Clamp2 FWD ( 005.07 ; Solenoid for Cylinder
Forward ) Clamp2 Forward
000.10 ; LS or Limit Switch Clamp2 REV
005.08 ; Solenoid for Cylinder
( Reverse)
Clamp2 Reverse
• Solenoid something high voltage and
something low voltage.

For DC Solenoid :
Red Cable Colour is Positive 24 Volt DC
Black Cable Colour is Negative 24 Volt DC


• Coil Relay, Coil Contactor, Source
Timer
This Component something high
voltage and something low voltage.