Professional Documents
Culture Documents
A knowledge about…
1. What is it? (name/specs)
2. For what? (function/s)
3. How to use it? (application)
Configuration of Tools
Pipe bender + vices
Bench vices 4”
Stork & dies
Metal cutter (scissors)
Cable stripper/cutter
Hand drill
Hand hacksaws
Pipe wrenches
Adjustable steel squares (10 cm/4”)
PVC tapes
Screw driver (X,-), test pen, long noose, etc.
Configuration of Tools (cont.)
Pipe bender + vices
Cable stripper/cutter
Function: to stripe/cut a cable/wire
How to use:
Similar to normal cutter (for cutting)
(For stripping):
Open the “mouth” of the stripper
Put the cable/wire through the opening
Close the “mouth” and stripe the cable with move it roundly in
closed “mouth” slightly until the PVC insulator was cut
Configuration of Tools (cont.)
Hand drill
Configuration of Tools (cont.)
Hand drill
Function: for screwing-in OR screwing-out
How to use: (screwing-in)
Put the screw at the drill tip (magnetic) if the screw is
outside the hole
Put it onto the wanted place
Pull the switch (hand-switch) until the screw was
tighten
* Use the opposite direction of direction-switch for
screwing-out
!!! Use hand drill for hard-
hard-drilling only
Configuration of Tools (cont.)
Hand hacksaws
Configuration of Tools (cont.)
Hand hacksaws
Function: to cut a conduit/trunking
How to use:
(Similar to normal saws)
Put a cutting-mark conduit into a vice
Put the blade of the handsaw on the mark
Start cut the conduit by moving with necessary force to
it until find the required result
PVC tapes
Function: as a marking for differentiate between
RYBEN cable if the cable used are in same colour
Used also for wiring (cable pulling)
How to use:
All cable those will be put into similar point/wiring path
are tied together with tape and put them through the
conduit
Configuration of Accessories
Trunking
Conduit
Socket outlet (3 phase)
1-way switch
2-way switch
Bus bars (3 phase)
Distribution Board box
Screws
Male – female adapter
Cable
3-phase supply cable
Clipper/saddle
Configuration of Accessories (cont.)
Trunking
Configuration of Accessories (cont.)
Conduit
Configuration of Accessories (cont.)
Socket outlet (3 phase)
E
E
N L
N L
Configuration of Accessories (cont.)
1-way switch
Life
L1
L2
N
Configuration of Accessories (cont.)
2-way switch
Life
L1
L2 L3
Configuration of Accessories (cont.)
Bus bars (3 phase)
Configuration of Accessories (cont.)
Distribution Board box
Configuration of Accessories (cont.)
Screws
To trunking /
accessories
To wall/bay
Configuration of Accessories (cont.)
Male – female adapter
Female
Male
Configuration of Accessories (cont.)
Conductor Cable
Size:
R E 2.5 mm2
4.0 mm2
B E = Earth
N = Neutral
N R = Red (Life)
Y = Yellow (Life)
Y
B = Blue (Life)
Configuration of Accessories (cont.)
3-phase supply cable
R
E
NY
5-pin plug B
Configuration of Accessories (cont.)
Clipper/saddle
Configuration of Equipments
MCCB 40A/10kA 4 pole
ELCB 40A/300mA 4 pole
Magnetic contactor
MCB 32A/4.5kA 3 pole
MCB 20A/4.5kA 1 pole
MCB 10A/4.5kA 1 pole
Fuse
Earth Bar
Neutral Bar
Emergency stop push button
D.O.L starter 18A
Thermal-Magnetic Circuit Breaker
Thermal-Magnetic Circuit Breaker
Mechanisms
Thermal action
Thermal-Magnetic Circuit Breaker
Mechanisms (cont.)
Magnetic action
Thermal-Magnetic Circuit Breaker
Mechanisms
Thermal + magnetic action
Configuration of Equipments (cont.)
MCCB 40A/10kA 3 pole
L1 L2 L3
Configuration of Equipments (cont.)
ELCB 40A/300mA 4 pole
L1 L2 L3 N
Configuration of Equipments (cont.)
Magnetic contactor
L1 L2 L3
NC
Configuration of Equipments (cont.)
MCB 32A/4.5kA 3 pole
L1 L2 L3
Life
Configuration of Equipments (cont.)
Earth Bar
Neutral Bar
Configuration of Equipments (cont.)
Emergency stop push button
Life
N
Configuration of Equipments (cont.)
D.O.L starter 18A (Direct On Line)
Configuration of Equipments (cont.)
D.O.L starter 18A
Configuration of Equipments (cont.)
D.O.L starter
18A circuit: