PERFORMANCE DATA

NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING


SERVICE DATA SHEET - 240389629 ICE MAKER INFORMATION
Type A With Run/Star t Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
R134a
ICE & WATER - AUTOMATIC DEFROST Test Cycling
Operating Time 32 to 40% 55 to 65%
SIDE BY SIDE MODELS Remove cover by inserting screwdriver in notch at bottom and prying
Freezer Temperature 0° to 4°F -1° to 3°F
-18° to -16°C -18° to -16°C
cover from housing. Use screwdriver to rotate motor gear
IMPORTANT SAFETY NOTICE counterclockwise until holding switch circuit is completed. All
Refrigerator Temperature 34° to 39°F 34° to 39°F
1° to 4°C 1° to 4°C The information provided herein is designed to assist qualified repair components of ice maker should function to complete the cycle.
Low Side Pressure (cut-in) 5 to 12 psig 5 to 12 psig
personnel only. Untrained persons should not attempt to make
34 to 83 kPa 34 to 83 kPa repairs due to the possibility of electrical shock. Disconnect power Water Fill Volume
Low Side Pressure (cut-out) -2 to 2 psig -2 to 2 psig cord before servicing. The water fill adjustment
-14 to 14 kPa -14 to 14 kPa
IMPORTANT screw will change the fill
High Side Pressure (Last 1/3 of cycle) 90 to 115 psig 130 to 155 psig time. One full turn is
621 to 793 kPa 896 to 1069 kPa If any green grounding wires are moved during servicing, they
equal to 20cc (.68 oz.).
must be returned to their original position and properly secured.
Wattage (Last 1/3 of cycle) 120 to 150 130 to 160 The correct fill is 102 to
Amps (Running) 1.2 to 1.5 1.2 to 1.5
130cc (3.4 to 4.3 oz.).
CAUTION: All electrical parts and wiring must be shielded When a water valve is
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max) from torch flame. Do not allow torch to contact insulation; it replaced, the fill volume
DEFROST SPECIFICATIONS will char at 200°F and flash ignite (burn) at 500°F. Excessive must be checked.
heat will distort the plastic liner.
Thermostat Heater
Cabinet Size
Cut-in Cut-out Watts Ohms

23' & 26' 25°F 47°F 450 30 NOTE: This product comes equipped with an Electronic Defrost
-4°C 8°C Control. To initiate defrost, depress the fresh food light switch 5
Electronic Timer - (ADC) Defrost 24 minutes ever y 6 to 72 hours of compressor run time. times in 6 seconds (light bulb must be working). To terminate
CONDENSER FAN MOTOR
defrost, depress the fresh food light switch 5 times in 6 seconds.

Watts RPM Amps

3.1 (Energy Star - Some models) 1100 CW Opposite Shaft .03 Running

8.0 2250 CW Opposite Shaft .07 Running


P-3
ICE MAKER SPECIFICATIONS

Electrical 115 vac (127 vac max) 60 Her tz

Thermostat Opens at 48°F (9°C) Closes at 15°F (-9°C)

Heater Wattage 165 P-4

ICE MAKER CONNECTOR PLUG CONNECTIONS

GREEN/YELLOW
Wire Number Wire Color Connects to:

1 Green/Yellow Ground GREEN/YELLOW

P-1
2 Yellow Water Valve P-2

3 Black Line

4 Lt. Blue Neutral

Get parts for your Frigidaire refrigerator at parts.fixitnow.com


ELECTRONIC DISPENSER

BLACK P.T.C. STARTER WITH RUN CAPACITOR


ELECTRO-MECHANICAL DISPENSER
DISPENSER

GRN/YEL
BLU/WHT (CUBE) LIGHT
WHITE WATER DISP. START 6 3
RED/BLK (120 VAC) RED/BLK (120 VAC)

LT. BLU
BROWN SWITCH
PURPLE (AUGER) WATER DISP. ICE DISP. S S
DC POWER SUPPLY 2

RED
SWITCH SWITCH COMM COMM RUN
LT. BLUE (NEUTRAL) ICE DISP. 5
AND RELAYS COMM COMM *
SWITCH NO NC NO NC
TAN (WATER VALVE) C L 1

RUN CAPACITOR
NO NC NO NC PURPLE (AUGER) M M
ORG/WHT (FAST FREEZE/ICE)
SLATE COMP. PTC
TAN (WATER VALVE) OVERLOAD
ORANGE MOTOR STARTER

CAPACITOR IS ONLY USED WITH

WHT/GRN (FAST ICE/WATER)


*
SOME P.T.C. MODELS.

ORANGE (WATER PADDLE)


SLATE (ICE PADDLE)

WHT/RED (WATER)
BLACK (DC GRD)

WHT/YEL (CUBE)

PURPLE (AUGER)
YELLOW (V IN)
(LINE) (NEUTRAL)

RED (+5 VDC)

BLUE (LIGHT)
FREEZER CONTROL NO
S4 S7 S6 S5 S2 S3 S1 C

NO NC NO NC NO NC NO NC NO NC NO NC NO NC
DAMPER MOTOR

FAST FREEZE FAST ICE CUBE CRUSH LIGHT RESET LOCKOUT

EVAP. FAN

COIL HEATER DEFROST


THERM.
FRESH FOOD
CONTROL
J8 J2 J10 J6
J3
J5
J7
ADAPTIVE COND. FAN
J12
DEFROST J9
III SEE
B

DISPENSER ASS'Y
SWITCHES SHOWN IN THE DAMPER OPEN POSITION COMPRESSOR
J11 RED GREEN
CRISP. MID LEVEL WIRING
COND. FAN
LIGHT LIGHT

LIGHT SOCKET
WIRING
J1 J4

SEE
DAMPER DAMPER
COMPRESSOR

SPLICE SWITCH MOTOR


WIRING

SPLICE
SEE

COMPRESSOR COLD AUTO


GRN/YEL

BLU/WHT
LT. BLU

ORG/WHT
GROUND CONTROLS
PURPLE

RED/BLK
SHOWN IN THE ICEMAKER
LT. BLU

YEL/RED

ON POSITION.
TAN

RED
FRZR DOOR
FRESH FOOD I/M WATER VALVE
GROUND DISPENSER HOUSING HEATER CONTROL
VIOLET W/ #3
HT
SEE MAIN WATER VALVE
#2
DISPENSER ASS'Y
CABINET GRN/YEL 1 WIRING
GROUND BLACK 2 DISPENSER WATER VALVE
LT. BLU 3
ALL WIRE CONNECTIONS YEL/BLK 4

P2
MARKED BY " " SYMBOL. RIBBED ORG/WHT 5
ACTUATOR,ICE DOOR
LIGHT SWITCH RED 6
(FRZR) BROWN 7
BOTTOM MOTOR,AUGER
WATER NON-RIBBED RED/WHT 8
VALVE ORANGE
ONE BLUE 9
BLACK FRZR. NEUTRAL WIRE
LT. BLU CONTROL
YEL/BLK FAST ICE
DIODE
DIODE

DIODES TO BE LIGHT SWITCH


POLARIZED AS TAN (REFRIG)

DEFROST POWER
POWER
DEF THERMO

COMPRESSOR
PURP/WHT
DAMPER MOTOR
EVAP FAN
DOOR SWITCH

NEUTRAL
F.F. COLD CNTRL

DAMPER SW. COMMON


FRZR. COLD CNTRL
SHOWN. YELLOW

FAST FREEZE
HEATER,ICE DOOR
RED
DRAIN ICE
WATER TROUGH MAKER MID LEVEL LIGHT
DISPENSER DEFROST GRN/YEL
VALVE THERM.
TWO LT. BLU BLACK
CRISPER LIGHT
BROWN BLU/WHT
SPLICE
BLUE
I/M FRZR.
AUGER
ASS'Y

GRN/YEL YELLOW

241526901C
WATER FAN
RED/WHT YEL/RED FRZR. LIGHT
VALVE DEFROST HEATER
TWO PURPLE
LT. BLU FREEZER LIGHT /
SAFETY SWITCH
MOLEX REFRIG. LIGHT
7 8 9 10 11 12
1 2 3 4 5 6 REFRIG. LIGHT SWITCH