1 Communication Protocol 2 Number marking 3 Line Stop 4 Tracking IPV OK / NOK signal 5 6 Torque tools & Nut runners

How will the Engine Srl No. and Model 7 information be send to Test machine Does the PLC support OPC connectivity 8 to exchange the data with MES?

10 11

12

13

In case it dose not support, then what open protocol it supports to communicate with third party software to exchange the data? OR The protocol is proprietary? Please provide the number IOs per PLC i.e. AI, AO, DI, DO, Special inputs/outputs if any Does each system have its dedicated SCADA or HMI? Does Pick-Light System support OPC connectivity to exchange the data with MES? Provide list of different equipment types with their system and OPC compatibility for each Line/ Shop e.g. OCR

Provide list of different registers available for communication and set of 14 valid values on each of these equipment For testing the interfaces and MES functionalities, are test simulators available? If not, how do you propose to do interface 15 testing? 1. PLC s and CNC machines should provide status signals over OPC. Status signals comprise of Start, stop, logical fault codes. Is there any other information provided as signals? 16 17 1. PLC should provide access to write data from MES to PLC data words. What are the different types of information (Events, Alarms, Messages, etc) provided by your system? In case any of this requires special handling please specify. 18 For OPC compliant devices, 19 pls provide following details a. OPC XML DA/HDA support or OPC/UA support with version? b. OPC configuration support? c. OPC data types support? d. OPC events support?

e. OPC connectivity type?

Description Will there be serial or Ethernet communication for Automatic and Semi-automatic machines (Like Valve seal assy, Leak test, Injector assy etc) Will the Host server communication be real time or after a defined frequency Will there be a scanner attached to the number marking m/c ? Type of stops - Fixed position stop or stoppage only at the end of Takt? Will the OEM have different triggers for different type of stops? Will the OEM give conveyor Index for the Engine assy line? How will MES get the IPV OK / NOK signal for 1. Maual stations 2. Semi automatic stations 3. Automatic stations How communication will be done? PLC or PC based?? How many different parameters (ex- Torque, angle, Upper or Lower limit etc..) MES needs to capture after tightening of each bolt?? Station wise List of Torque tools and Nut runners on the line Will there be any cycle completion signal by the Torque tool after finishing the operation for a job on the station Through Barcode scan at the test m/c or it is to be sent by MES DC?

OPC Complaince

Alternate if not OPC Complaint

Pick Light System

S.NO 1 2 3 4 5 6 7 8

OEM CONTROLLER DETAILS TO COMMUNICATE WITH MES DATA CONCENTRATOR DESCRIPTION Example Controller Allen Bradley, Siemens etc.. CPU Control Logix / Compact Logix Model / CAT No. 1756 - 5563 Communication Port Availability Built in Port or Additional Communication Card added Dedicated port left for MES Yes / No Port Configured for Communication Yes / No Communication Protocol Rockwell TCP / IP, Rockwell DF1, Rockwell DH+, Rockwell DH485 Etc. Communication Speed xxx Kbs/sec. or Mb's / sec.