You are on page 1of 17
Renna Measuring soft work- pieces 2-16 Further components are: RDS/XXT Adapter plate only in connection with RDS articulating head VAST XXT Changer rack One unit with three holders for the stylus holder. The unit is attached to the profile rail of a change rack. Stylus kit There are three different stylus system kits. For conversions of a CMM , conversion parts may additionally be nec- essary. Moreover, the system requirements must be observed. Application The VAST XXT probing system can be used universally. It is possible to probe discrete points or perform scannings. Measurements performed with this system provide information on the dimensions, position and form of a workpiece. Characteristics = Scanning = Automatic stylus system change — Low deviation by measuring system = Robustness — Different probe variants are available, — depending on the stylus length and application Advantages The VAST XXT is particularly suitable for measuring soft workpieces. Due to the low measuring force, deformations on the workpiece and thus incorrect measurements are avoided. Use The VAST XXT can be used in two ways: — in combination with the RDS articulating head > “RDS/XXT prob- ing system” on page 2-35 — as central probe on a rigid adapter. The adapter is attached to the ram. The second possibility is not possible for all CMMs. 61211-6080602 Sensors Operating Instructions RECs: robing systems Components A Adapter; attached to ram B Probe VAST XxT 1 LED; 3 pieces Left: LED for probe; permanently lit if probe is connected to the adapter Center: System clock pulse LED Right: Power LED; permanently lit 2. Knurled ring for screwing to adapter 3. Stylus holder receptacle 61211-6080602 Sensors Operating Instructions 2 -17 Geo acnn Marking | NOTE = NOTE & mene ts 2-18 Stylus holder The stylus holder is held magnetically and can be inserted manually or automatically. The three outer spheres on the stylus holder serve for adjusting the correct position in the stylus holder receptacle. The cor- rect fit of these spheres is monitored electronically. The fourth sphere servers for mechanically coding the stylus holder type. Laterally on the stylus holder, there are black markings at a distance of 120°. The markings are in the form of one, two or three dots. They serve for a better orientation when inserting the stylus holder. A spe- ial stylus holder is provided for each design version. 1. The inner sphere serves for the mechanical coding of the different stylus holders; a stylus holder for TL1 is shown. With TL2, the inner sphere is even closer to the magnet. Magnet Chip for marking the stylus holder Lateral marking on the stylus holder; for orientation Outer spheres serve for monitoring the correct position of the stylus holder in the stylus holder receptacle. wun The arrangement of the pair of spheres is different in TL1 and TL2 Thereby it is prevented that accidentally the wrong stylus holder is inserted in the probe. The correct fit of the stylus holder must be checked. * Tr to carefully twist the stylus holder. if you feel a slight resistance, then the stylus holder fits correctly in the receptacle of the probe. The 18-pole VAST XXT probe requires a stylus holder with ID chip. Sty- lus holders without ID chip are no longer supported. 61211-6080602 Sensors Operating Instructions

You might also like