LOSS PREVENTION CERTIFICATION BOARD

RED BOOK 2011 Volume 1 LIST OF APPROVED PRODUCTS AND SERVICES

- FIRE DETECTION AND ALARM PRODUCTS & SERVICES - FIRE SUPPRESSION PRODUCTS & SERVICES - RELATED INSTALLERS

A Specifiers Guide

CONTENTS
1 Fire detection and alarm products, systems & cables 1 SECTION 1 LPS 1014 certified fire detection and alarm system firms 3 SECTION 2 Fire detection and alarm systems 14 SECTION 3 Control and indicating equipment 17 SECTION 4.1 Commercial detectors 147 SECTION 4.2 Domestic alarms - smoke, heat and carbon monoxide 269 SECTION 5 Manual call points 274 SECTION 6 Line units 300 SECTION 7 Alarm Warning Devices 319 SECTION 8 Fire resistant cables 360 SECTION 9 Alarm receiving centres 428 SECTION 10 Alarm transmission and fault monitoring equipment and signalling systems 430 SECTION 10.1 Alarm transmission and fault routing equipment 432 SECTION 10.2 Alarm transmission and fault routing equipment and systems 433 SECTION 10.3 Signalling systems 437

ii

12 Sep 2011

INDEX
2 2M KABLO SAN. ve TIC. A.S. 362 A AC Electrical Wholesalers Ltd 363 ADI International 148, 300 ADT Fire and Security 3, 4 Advanced Electronics Limited 18, 150, 274, 301, 320 Advantronic Systems S.L. 152, 275, 320 AEI Cables Limited 363 Aguilera Electronica S.L 153 Alarm Supply Pte Ltd 154 Alberta Fire & Security Equipment Limited 5 Alpha Fire Services W.L.L. 368 AMPAC Europe Limited 19 AMPAC Technologies PTY Ltd 20, 275 Apollo Fire Detectors Limited 155, 276, 301, 320 Application Solutions (Safety & Security) Ltd 21 Argus Fire Protection Company Limited 5 Argus Security S.r.l. 163, 277, 303, 322 Argus-Spectrum Co 166, 277, 322 ATEIS Middle East FZCO 168, 277, 323 ATOM KABLO SANAYI VE TICARET A.S. 368 Autronica Fire & Security AS 303, 323 B Bailey Maintenance 5 Bangkok Cable Co Limited 368 Banham Alarms (Prop Banham Patent Locks Limited) 428 Bardic by Honeywell 22, 170 BBC Fire Protection Limited 5 Beijing Leader Huaxin Electronics Co. Ltd 171 Bentel Security s.r.l. 278 Biamp Systems Corporation 22 BT Redcare 433, 437 C Carillion 23 Cavicel SpA 370 CEAG 24 Ceasefire Industries Ltd 171, 278, 324 Chubb Fire & Security Limited 5 Chubb Fire Ltd 172, 303 Chubb Scurit 25 Clymac Limited 6 Computionics Limited (Trading as C-Tec) 27 Consilium Marine and Safety AB 172 Context Plus Ltd 173, 278, 304, 372 Control Equipment Limited 14, 33 Cooper Controls Limited (trading as Integrated Solutions) 6 Cooper Fulleon Limited 279, 326 Cooper Industries Inc 36, 173, 279 Cooper Lighting and Safety Ltd 37 Cooper Safety 174 Cooper Scurit SAS 177 Cranford Controls Limited 326 CSL DualCom Limited 434 CTM Fire and Security Limited (Leyland & London Offices) 6 D Daemon Fire and Security Limited 6 Dtwyler Cables 373 Defensor Group Limited 6 Detector Electronics Corporation 39, 178, 304 Digital Security Controls, a Division of Tyco Safety Products Canada Ltd 269 Direction Fire Limited 7 Doncaster Cables 374 Draka UK Limited 375 Dubai Cable Company (Private) Limited 379 Dubai Cable Company (Private) Limited, Trading as Ducab 380, 381 E Eland Cables 384 EMCO 178, 280, 327 EMCOR Facilities Services Limited, EMCOR Specialist Services 7 EMCS - East Midlands Central Station Limited 428 Emergi-Lite Safety Systems (Thomas & Betts Ltd) 180, 280, 305 Emirates Fire Fighting Equipment Factory L.L.C. (FIREX) 181, 280, 327, 384 Eurotech Fire Systems Ltd 182 Everday Technology Co. Limited 183, 280 Eyston Company Ltd 270 F FFE Fire & Security Limited 7 Fike Safety Technology Ltd 40 Fire Fighting Enterprises Ltd 184 FireAngel Ltd (A Division of Sprue Aegis plc) 270 Fireblitz Extinguisher Ltd 271 Fireguard Safety Equipment Co Ltd 184, 281, 327, 385 Firelite by Honeywell 41 Fireonica Co. Ltd 185, 281 Firetecnics Systems Limited 7 FIREX Protection System Technology Ltd 42, 186, 281, 305, 328 G GBE Fire & Security (a division of GB Electronics Limited) 7 GE Security Inc 306 GE Security Inc (Trading As Edwards System Technology) 187, 306, 328 Gent By Honeywell 43, 188, 282, 307, 328 GEZE GmbH 192 Gira Giersiepen Gmbh & Co. KG 271 Global System Technology Plc 47, 192, 282, 307, 333, 385 Grainger Fire Systems 8 Group 4 Securicor Plc 49, 193, 283, 308, 333 Grupo General Cable Sistemas, S.A. 386, 387 Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC) 51, 194, 283, 308, 333 H Haes Systems Limited 53 Hall & Kay Fire Engineering (Thame) 8

12 Sep 2011

iii

INDEX
Hallmark Fire (a division of SFS Fire Services Ltd) 8 HDR 195, 283, 308, 334 Hochiki America Corporation 196 Hochiki Corporation 197 Hochiki Europe (UK) Limited 197, 284, 309, 336 Honeywell Automation (I) Pvt. Ltd 202 Honeywell Control Systems Limited 202, 309 Honeywell Control Systems Ltd 54, 205, 284, 310 Honeywell International Inc 59 Horing LIH Industrial Co Ltd 206, 285, 344 Hosiden Besson Limited 345 Huzhou Jiusheng Electric Co Ltd 388 I I.C. Service & Maintenance Limited 8 Industrial Scientific Oldham 207 INIM Electronics s.r.l. 209, 310 Irish Driver-Harris Company Limited 388 J Jaylow Supplies Ltd 393 K KAC Alarm Company Limited 285, 346 Keystone Electric Wire & Cable Company Ltd 394 Kidde Finland Oy 271 Kidde Products Ltd 210 Kidde Products Ltd, trading as AirSense Technology 211 Kidde Safety Europe Ltd 272 Kingfell Plc 8 Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security 9 KME Italy SpA 395 L Labor Strauss Sicherungsanlagenbau GmbH 212, 289 LEONI Studer AG 396 Lichfield Fire & Safety Equipment Co. Ltd 213 Lloret Fire and Security Limited 9 M M. J. Quinn Integrated Services Limited 9 Mavili Elektronik Ticaret Ve Sanayi A.S. 213 MECE Fire & Security Limited 9 Mercury Engineering 9 MGC Systems Corp. 289 MITIE Technical Facilities Management Limited 10 MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems) 10 Morley-IAS Fire Systems By Honeywell 60, 214, 216, 290, 310, 349 MSA AUER 217 Multron Systems Pte Ltd 68, 218, 290, 311, 349 N NAJD ELECTRICALS & SAFETY EQUIPMENT TRADING 401 National Monitoring (Prop. AVR Group Limited)429 Nexans Turkiye Endustri ve Ticaret A.S. 402 Ningbo Siterwell Electronics Co., Ltd. 272 Niscayah Limited 10 Nitin Ventures FZE 69, 219, 291, 311 Nittan (UK) Limited 220 Nittan Fire Protection (Zhongshan) Co Ltd 221 Norden Communication UK Ltd 403 Notifier by Honeywell 291, 350 Notifier Fire Systems by Honeywell 16, 71, 222, 311 Notifier Fire Systems India 225 O OG Elektronik 225, 292, 351 Olympia Electronics S.A. 78 P PEL Services Limited 10 Pelco Finland Oy 79, 227, 292, 312 Philton Fire & Security Limited 229 Pittway Tecnologica Srl. 230, 312 Plana Fabrega 234 Protec Fire Detection plc 11, 82, 235, 292, 313, 351 Prysmian Cables & Systems Limited 403 Prysmian Cables & Systems Ltd 404 Prysmian Power Cables & Systems Australia Pty Limited 411 R R & S Fire & Security Services Limited 11 RAMCRO S.p.A 412 Raysil Security Systems Limited 11 S Safety Technology International (Europe) Limited 293 Safex Fire Services Limited 239 Sareme UAB 239, 293 Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southhampton) 240 Scotshield Limited 11 Security Services (Prop Bryan Enterprises Ltd.) 429 Shakun Polymers Limited 414 SHIELD FIRE, SAFETY & SECURITY LTD 85, 240, 293, 313, 352, 414 Siemens plc, Building Technologies, Fire Safety Division 12 Siemens Switzerland Limited, Building Technologies Division 86, 241, 294, 313, 352 SMS 94, 245, 295, 315 Southern Monitoring Services Limited 429 Spectrex Inc 246 Static Systems Group Plc 12 Sterling Safety Systems 248, 295, 353 Suzhou Cableplus Technologies Co., Ltd. 415 Synaps Technology Srl 295 System Sensor 250 System Sensor Europe 353 System Sensor, Honeywell International (I) PVT. Limited 251 T T V F (UK) Limited 12 Tai Sin Electric Limited 415 Talentum Developments Limited 253 Tamlite Emergency & Fire 254 Teledata S.r.l. 254, 296, 355 TELE-FONIKA Kable Sp. z o.o., S.K.A. 416

iv

12 Sep 2011

INDEX
Texecom Ltd 355 Thameside Fire Protection Co. Limited 12 Thorn Security Limited, Trading as Tyco Safety Product 95 Thorn Security Limited, trading as Tyco Safety Products 256, 296, 315, 357 Tratos Cavi SpA 419 Trinity Protection Systems Limited 12, 13 Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) 13 Tyco Thermal Controls Canada Limited 420 Tyco Thermal Controls Huzhou Co Limited 421 Tyco Thermal Controls UK Ltd 423 U Union Cable Company Ltd 425 UTC Fire & Security (Africa) trading as Ziton 16, 105, 259, 316 UTC Fire & Security (Pty) LTD Trading as Ziton 296 UTC Fire & Security Americas Corporation, Inc. 119, 259, 297, 316 UTC Fire & Security BV 120, 259, 298, 317 UTC Fire & Security Inc. Trading as Edwards Systems Technology 358 V Ventcroft Limited 425 Vimpex Limited 317, 359 Vipond Fire Protection Limited 13 Visonic 272 VRC Terofire Products 262 W WebWayOne Ltd 434 Weckx Handelsonderneming 273 Wrexham Mineral Cables 426 X Xtralis Pty Limited 144, 262 Z Zeta Alarm Systems by GLT Exports Limited 144, 267, 273, 299, 318, 359, 427

12 Sep 2011

Part 1
FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS & CABLES

PART 1: FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS &


CABLES
Introduction A working fire detection and alarm system will increase the level of safety in a building by automatically warning occupants of fire before they would otherwise detect it.. To ensure the system works, the system must be designed correctly, products must be correctly selected and the systems must be correctly installed and maintained. It is recommended that all systems are designed, installed, commissioned and maintained by contractors who are approved by LPCB to LPS 1014 and that they are connected to Alarm Receiving Centres approved to LPS 1020. Listings in this section include: Products Control & indicating equipment and power supplies Flame, beam, aspirating, smoke, heat and multi-sensor detectors Manual call points Line units Sounders Cables Alarm transmission equipment Signalling systems Products are approved in accordance with a range of standards. The details of these standards are given at the front of each section relevant to the product. Systems Fire detection and alarm systems are approved for system compatibility in accordance with: LPS 1054: Requirements and testing procedures for the approval and listing of component compatibility for fire detection and alarm systems. EN 54 - Part 13: Compatibility assessment for system components. Design, installation, commissioning and maintenance contractors. Contractors are approved in accordance with: LPS 1014: Requirements for certificated fire detection and alarm system firms. LPS 1020 - Alarm Receiving Centres

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS WHY USE AN LPS 1014 APPROVED COMPANY? Even with the best equipment, fire detection and alarm systems are only effective if correctly designed, installed, commissioned and serviced. It is therefore important that specifiers select only competent firms with a proven track record to undertake the work. LPS 1014 Requirements for Certificated Fire Detection and Alarm System Firms meets these requirements in full. LPS 1014 requires one encompassing Certificate of Conformity for the project, i.e. single point responsibility, which benefits all parties concerned, i.e. the insurer, the fire brigade, the building owner, etc. It is based on BS 5839-1 and also requires the use of third party approved products. For each system specifiers should request the issue of an LPCB Certificate of Conformity as part of the contract which: certifies that the fire detection and alarm system was designed, installed and commissioned in accordance with the installation rules applied, and ensures that the system is recorded by LPCB as a certificated fire detection and alarm installation.

The availability of more varied and sophisticated fire detection and alarm equipment means that it is even more important that firms listed to LPS 1014 are regularly assessed by LPCB for their competence to design, install, commission and service fire detection and alarm systems in accordance with acceptable installation rules or codes of practice. Additional offices Where a firm has additional offices, each office must meet the requirements of LPS 1014 to be eligible for certification, and is separately listed. Provisional Approval Firms with limited experience and track record can gain Provisional Approval in the LPS 1014 scheme. Their work is closely monitored by LPCB and when they have completed the requisite number of fire detection and alarm systems contracts over a period of not less than 2 years, and subject to satisfactory performance, they will be given full approval and listed in this section of the Red Book.

ADT Fire and Security


Security House, The Summit, Hanworth Road, Sunbury on Thames, Middlesex TW16 5DB, United Kingdom Tel: +44 (0)1932 743456 Fax: +44 (0)1932 743222
Certificate No. CFA-105 to LPS 1014

ADT Fire and Security


ADT House, 5th Avenue Business Park, Team Valley Trading Estate, Gateshead, Tyne and Wear NE11 0HF, United Kingdom Tel: +44 (0)191 451 5000 Fax: +44 (0)191 487 9543
Certificate No. CFA-111 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

ADT Fire and Security


Unit 5, Redwing Court Business Centre, Ashton Road, Romford, Essex RM3 8QQ, United Kingdom Tel: +44 (0)2082 724700 Fax: +44 (0)2082 724709
Certificate No. CFA-112 to LPS 1014

ADT Fire and Security


ADT House, Tannochside Park, Uddingston, Glasgow G71 5PH, United Kingdom Tel: +44 (0)1698 486000 Fax: +44 (0)1698 486100
Certificate No. CFA-113 to LPS 1014

ADT Fire and Security


Quay House, City Park Business Village, Manchester M16 9UN, United Kingdom Tel: +44 (0)1612 525500 Fax: +44 (0)1612 525688
Certificate No. CFA-109 to LPS 1014

ADT Fire and Security


ADT House, Mucklow Hill, Halesowen, Birmingham, West Midlands B62 8DA, United Kingdom Tel: +44 (0)1212 556000 Fax: +44 (0)1212 556100
Certificate No. CFA-108 to LPS 1014

ADT Fire and Security


180 Aztec West, Almondsbury, Bristol BS32 4TH, United Kingdom Tel: +44 (0)1454 843434 Fax: +44 (0)1454 843484
Certificate No. CFA-107 to LPS 1014

ADT Fire and Security


1 Bowling Green Terrace, Off Jack Lane, Leeds LS11 9SX, United Kingdom Tel: +44 (0)1132 911000 Fax: +44 (0)1132 425933
Certificate No. CFA-110 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Alberta Fire & Security Equipment Limited


San Gwakkin Road, Mriehel, BKR 3000, Malta Tel: +356 21 443538 Fax: +356 21 484077 E-mail: info@alberta.com.mt Website: www.alberta.com.mt
Certificate No. CFA-177 to LPS 1014

Argus Fire Protection Company Limited


Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom Tel: +44 (0)1384 376256 Fax: +44 (0)1384 393955 E-mail: info@argusfire.co.uk Website: www.argusfire.co.uk
Certificate No. CFA-148 to LPS 1014

Bailey Maintenance
7 Brown Lane West, Leeds LS12 6EH, United Kingdom Tel: +44 (0)113 234 3443 Fax: +44 (0)113 222 3925 E-mail: enquiries@baileymaintenance.co.uk Website: www.baileymaintenance.co.uk
Certificate No. CFA-165 to LPS 1014

BBC Fire Protection Limited


St Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH, United Kingdom Tel: +44 (0)1953 857700 Fax: +44 (0)1953 857750 E-mail: sales@bbcfire.co.uk Website: www.bbcfire.co.uk
Certificate No. CFA-126 to LPS 1014

Chubb Fire & Security Limited


400 Dallow Road, Luton, Beds LU1 1UR, United Kingdom Tel: +44 (0)1582 413694 Fax: +44 (0)1582 456353 E-mail: quality.fireuk@chubb.co.uk Website: www.chubb.co.uk
Certificate No. CFA-121 to LPS 1014

Chubb Fire & Security Limited


5 Canal Place, Armley Road, Leeds LS12 2DU, United Kingdom Tel: +44 (0)113 235 5131 Fax: +44 (0)113 235 5132 E-mail: fire.leeds@chubb.co.uk Website: www.chubb.co.uk
Certificate No. CFA-120 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Clymac Limited
Cloudway Court, Belton Road, Loughborough LE11 1LW, United Kingdom Tel: +44 (0)1509 232651 Fax: +44 (0)1509 232665 E-mail: sales@clymac.co.uk Website: www.clymac.co.uk
Certificate No. CFA-154 to LPS 1014

Cooper Controls Limited (trading as Integrated Solutions)


26 Greenhill Crescent, Watford Business Park, Watford, Hertfordshire WD18 8XG, United Kingdom Tel: +44 (0)1923 495495 Fax: +44 (0)1923 228796 E-mail: sales@polaron.com Website: www.polaron.com
Certificate No. CFA-162 to LPS 1014

CTM Fire and Security Limited (Leyland & London Offices)


Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW, United Kingdom Tel: +44 (0)800 5872753 Fax: +44 (0)1772 641227 E-mail: ctmfire@btconnect.com Website: www.firealarmuk.com Including the following satellite offices: BBC Television Centre, Arch 118, Dodds Yard, Wood Lane, London W12 7RJ Tel: +44 (0)208 225 9427 Fax: +44 (0)208 225 9446
Certificate No. CFA-156 to LPS 1014

Daemon Fire and Security Limited


Daemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS, United Kingdom Tel: +44 (0)1827 69266 Fax: +44 (0)1827 53584 E-mail: sales@daemonfire.co.uk
Certificate No. CFA-145 to LPS 1014

Defensor Group Limited


11-15 Kingsley Street, Leicester LE2 6DY, United Kingdom Tel: +44 (0)116 244 8689 Fax: +44 (0)116 244 8884 E-mail: j.kyte@defensorfds.co.uk
Certificate No. CFA-161 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Direction Fire Limited


Units 4 & 5 Fire Quarter, Blenheim Road, Epsom, Surrey KT19 9QN, United Kingdom Tel: +44 (0)1372 744499 Fax: +44 (0)1372 741188 E-mail: general@directionfire.co.uk Website: www.directionfire.co.uk
Certificate No. CFA-178 to LPS 1014

EMCOR Facilities Services Limited, EMCOR Specialist Services


Premier House, Tollgate, Eastleigh, Hampshire SO53 3YE, United Kingdom Tel: +44 (0)2380 648028 Fax: +44 (0)2380 648191 E-mail: david.parker@emcoruk.com
Certificate No. CFA-151 to LPS 1014

FFE Fire & Security Limited


122 The Minories, London EC3 1NT, United Kingdom Tel: +44 (0)845 60 999 06 Fax: +44 (0)20 8665 4125 E-mail: enquiries@ffe.co.uk Website: www.ffe.co.uk Including the following satellite office at: Unit 20, Tait Road Industrial Estate, Tait Road, Croydon CR0 2DP
Certificate No. CFA-152 to LPS 1014

Firetecnics Systems Limited


142 Vauxhall Street, London SE11 5RH, United Kingdom Tel: +44 (0) 20 7587 0927 Fax: +44 (0) 20 7582 3496 E-mail: info@firetecnics.co.uk Website: www.firetecnics.com
Certificate No. CFA-146 to LPS 1014

GBE Fire & Security (a division of GB Electronics Limited)


Unit C2, Elmbridge Court, Cheltenham Road East, Gloucester GL3 1LZ, United Kingdom Tel: +44 (0)845 1220884 Fax: +44 (0)845 1220885 E-mail: info@bge-uk.com Website: www.gbe-uk.com
Certificate No. CFA-180 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Grainger Fire Systems


Thornley House, Carrington Business Park, Carrington, Manchester M31 4XL, United Kingdom Tel: +44 (0)161 777 6700 Fax: +44 (0)161 777 6638 E-mail: info@grainger-fire.co.uk The following location is included within the scope of certification for servicing: Unit 1A, Newton Court, Wavertree Technology Park, Wavertree, Liverpool L13 1EJ Tel: +44 (0)151 220 4068 Fax: +44 (0)151 259 4365
Certificate No. CFA-125 to LPS 1014

Hall & Kay Fire Engineering (Thame)


Thame Park Road, Thame, Oxfordshire OX9 3RT, United Kingdom Tel: +44(0) 1844 265008 Fax: +44(0) 1844 265008 E-mail: detection@hkfire.co.uk Website: www.hkfire.co.uk
Certificate No. CFA-147 to LPS 1014

Hallmark Fire (a division of SFS Fire Services Ltd)


Systems House, Stoke Road, Hoo, Rochester, Kent ME3 9NT, United Kingdom Tel: +44 (0)8700 111150 Fax: +44 (0)8700 111160 E-mail: sales@hallmarkfire.co.uk Website: www.hallmarkfire.co.uk
Certificate No. CFA-140 to LPS 1014

I.C. Service & Maintenance Limited


Unit K3 Temple Court, Knights Park, Knight Road, Strood, Kent ME2 2LT, United Kingdom Tel: +44 (0)1634 290300 Fax: +44 (0)1634 290700 E-mail: sales@icservice.biz Website: www.icservice.biz
Certificate No. CFA-158 to LPS 1014

Kingfell Plc
Capital Tower, 12th Floor, 91 Waterloo Road, London SE1 8RT, United Kingdom Tel: +44 (0)845 60 61 999 Fax: +44 (0)845 25 81 999 E-mail: enquiries@kingfell.com Website: www.kingfell.com
Certificate No. CFA-138 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security


1 Riverside Industrial Estate, Dogflud Way, Farnham GU9 7UG, United Kingdom Tel: +44 (0)1252 710809 Fax: +44 (0)1252 710816 E-mail: info@kingfishersecurity.co.uk Website: www.kingfishersecurity.co.uk
Certificate No. CFA-176 to LPS 1014

Lloret Fire and Security Limited


24 Ullswater Crescent, Ullswater Business Park, Coulsdon, Surrey CR5 2HR, United Kingdom Tel: +44 (0) 208 410 4600 Fax: +44 (0) 208 668 9141 E-mail: david.drouin@lloret.co.uk Website: www.lloret.co.uk
Certificate No. CFA-181 to LPS 1014

M. J. Quinn Integrated Services Limited


Oak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB, United Kingdom Tel: +44 (0)151 547 8800 Fax: +44 (0)151 547 8801 E-mail: enquiries@mjquinn.co.uk Website: www.mjquinn.co.uk
Certificate No. CFA-137 to LPS 1014

M. J. Quinn Integrated Services Limited


5th Floor, 119 Farringdon Road, London EC1R 3DA, United Kingdom Tel: +44 (0)207 239 8750 Fax: +44 (0)207 239 8751 E-mail: enquiries@mjquinn.co.uk Website: www.mjquinn.co.uk
Certificate No. CFA-143 to LPS 1014

MECE Fire & Security Limited


Courtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS, United Kingdom Tel: +44 (0)1634 260607 Fax: +44 (0)1634 260278 E-mail: enquiries@mecefireandsecurity.co.uk Website: www.mecefireandsecurity.co.uk
Certificate No. CFA-159 to LPS 1014

Mercury Engineering
Mercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, Ireland Tel: +353 1 216 3000 Fax: +353 1 216 3006 E-mail: fireprotection@mercury.ie Website: www.mercury.ie
Certificate No. CFA-174 to LPS 1014

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

MITIE Technical Facilities Management Limited


Limeharbour Court, 5 Limeharbour, London E14 9RH, United Kingdom Tel: +44 (0)20 7001 7000 Fax: +44 (0)20 7001 7272 E-mail: MTFM.Rail.FireProjects@mitie.com Website: www.mitie.com
Certificate No. CFA-129 to LPS 1014

MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems)
Ventura House, Ventura Park Road, Tamworth B78 3HL, United Kingdom Tel: +44 (0)1827 303251 Fax: +44 (0)1827 309798 Website: www.mitie.com
Certificate No. CFA-163 to LPS 1014

Niscayah Limited
Roding House, 970 Romford Road, London E12 5LP, United Kingdom Tel: +44 (0)20 8553 5932 Fax: +44 (0)20 8478 8052 E-mail: info@niscayah.co.uk Website: www.niscayah.co.uk
Certificate No. CFA 169 to LPS 1014

PEL Services Limited


Belvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ, United Kingdom Tel: +44 (0)20 8839 2100 Fax: +44 (0)20 8841 1948 E-mail: pel@pel.co.uk Website: www.pel.co.uk
Certificate No. CFA-179 to LPS 1014

10

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Protec Fire Detection plc


Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 Fax: +44 (0)1282 717273 E-mail: sales@protec.co.uk Website: www.protec.co.uk Including the following satellite offices: Unit 4, White Oak Square, London Road, Swanley, Kent BB8 1AG, United Kingdom Tel: +44 (0)845 456 5394 Fax: +44 (0)845 456 5395 Unit 10, Fulcram 4, Solent Way, Whiteley, Fareham, Hampshire PO15 7FT, United Kingdom Tel: +44 (0)845 456 5392 Fax: +44 (0)845 456 5393 5 Morston Court, Blakeney Way, Kingswood Lakeside, Cannock, Staffordshire WS11 8JB, United Kingdom Tel: +44 (0845 456 5398 Fax: +44 (0845 456 5399 Unit 1, Ashfield Court, Whitehall Road, Leeds LS12 5JB, United Kingdom Tel: +44 (0)845 456 53388 Fax: +44 (0)845 456 53389
Certificate No. CFA-132 to LPS 1014

R & S Fire & Security Services Limited


Trafalgar House, 712 London Road, Grays, West Thurrock, Essex RM20 3JT, United Kingdom Tel: +44 (0)1708 683040 Fax: +44 (0)1708 683068 E-mail: sales@rs-fire.com Website: www.rs-fire.com
Certificate No. CFA-172 to LPS 1014

Raysil Security Systems Limited


Unit 16, Red Lion Business Centre, 218 Red Lion Road, Surbiton, Surrey KT6 7QD, United Kingdom Tel: +44 (0)20 8391 0202 Fax: +44 (0)20 8391 4758 E-mail: enquiries@raysil.co.uk Website: www.raysil.co.uk
Certificate No. CFA-127 to LPS 1014

Scotshield Limited
Century House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH, United Kingdom Tel: +44 (0)1236 767788 Fax: +44 (0)1236 762233 E-mail: j.baxter@scotshield.com Including the following satellite office for service work only Unit 2, 9 Lotland Street, Inverness ML1 8QH Tel: +44 (0)1463 709637 Fax: +44 (0)1463 709638
Certificate No. CFA-150 to LPS 1014

12 Sep 2011

11

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Siemens plc, Building Technologies, Fire Safety Division


Brunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD, United Kingdom Tel: +44 (0)1276 696000 Fax: +44 (0)1276 696133 E-mail: sales.uk.sbt@siemens.com Website: www.siemens.co.uk/buildingtechnologies
Certificate No. CFA-100 to LPS 1014

Static Systems Group Plc


Heath Mill Road, Wombourne, Staffordshire WV5 8AN, United Kingdom Tel: +44 (0)1902 895551 Fax: +44 (0)1902 324969 E-mail: sales@staticsystems.co.uk Website: www.staticsystems.co.uk
Certificate No. CFA-135 to LPS 1014

T V F (UK) Limited
59-69 Queens Road, High Wycombe, Buckinghamshire HP13 6AH, United Kingdom Tel: +44 (0)1494 450641 Fax: +44 (0)1494 465378 E-mail: customer.service@tvfltd.co.uk Website: www.tvfltd.co.uk
Certificate No. CFA-128 to LPS 1014

Thameside Fire Protection Co. Limited


Unit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD, United Kingdom Tel: +44 (0)1268 597999 Fax: +44 (0)1268 597998 E-mail: enquiries@thamesidefire.co.uk Website: www.thamesidefire.co.uk
Certificate No. CFA-171 to LPS 1014

Trinity Protection Systems Limited


Little Bridge Business Park, Oil Mill Lane, Clyst St.Mary, Exeter, Devon EX5 1AG, United Kingdom Tel: +44 (0)1392 874455 Fax: +44 (0)1392 875546 E-mail: info@trinityprotection.co.uk Website: www.trinityprotection.co.uk
Certificate No. CFA-160 to LPS 1014

Trinity Protection Systems Limited


Unit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 INP, United Kingdom Tel: +44 (0)1926 485080 Fax: +44 (0)1926 485090 E-mail: info@trinityprotection.co.uk Website: www.trinityprotection.co.uk
Certificate No. CFA-167 to LPS 1014

12

12 Sep 2011

PART 1: SECTION 1
LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

Trinity Protection Systems Limited


121A Milton Park, Abingdon, Oxfordshire OX14 4SA, United Kingdom Tel: +44 (0)1235 862456 Fax: +44 (0)1235 834450 E-mail: info@trinityprotection.co.uk Website: www.trinityprotection.co.uk
Certificate No. CFA-168 to LPS 1014

Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA, United Kingdom Tel: +44 (0)1454 240071 Fax: +44 (0)1454 626443 Website: www.tycofis.com
Certificate No. CFA-170 to LPS 1014

Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN, United Kingdom Tel: +44 (0)1753 574111 Fax: +44 (0)1753 824226 Website: www.tycofis.com
Certificate No. CFA-157 to LPS 1014

Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)
Hillcrest Business Park, Cinderbank, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458993 Fax: +44 (0)1384 458981 Website: www.tycofis.com
Certificate No. CFA-103 to LPS 1014

Vipond Fire Protection Limited


10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA, United Kingdom Tel: +44 (0)1355 2375 25/80/88 Fax: +44 (0)1355 263399 E-mail: admin.uk@vipondltd.co.uk Website: www.vipondfire.co.uk
Certificate No. CFA-173 to LPS 1014

12 Sep 2011

13

PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS A fire detection and fire alarm system is typically made up of a number of inter-linked components including detectors, manual call points, and alarm sounders connected to control and indicating equipment by means of one or more transmission paths. All system components, including the control and indicating equipment are also connected to a power supply directly or indirectly. A fire detection and alarm system may be linked to other systems such as fire protection, or building management systems. These other systems are not considered as part of the fire detection and alarm systems. The fire detection and alarm systems may be networked together. Each of the components that constitute the fire detection and alarm system may be individually tested and approved against their appropriate standard to demonstrate their own performance and reliability but in order to ensure their compatibility and performance together within the system, certain system tests and requirements must be fulfilled. The system standard specifies the requirements for compatibility and connectability assessment of system components that either comply with the requirements of EN 54 and/or with a manufacturers specification. The standard also includes requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This section lists approved fire detection and alarm systems suitable for use in buildings for the protection of people and property. The system requirements ensure the compatibility of the different components of the system work reliably together. Each component of the fire detection and alarm systems listed in this section are approved to the applicable product standard and are listed in Sections 3, 4.1, 5, 6, and 7. The approval process for the system is outlined in scheme document SD040. Systems listed in this section have been approved to LPS 1054: 2001 Requirements for the evaluation of component compatibility for fire alarm systems This standard was designed for the UK market and applies to systems incorporating control and indicating equipment and power supply equipment complying with EN 54-2 Fire detection and fire alarm systems Control and indicating equipment and EN 54-4 Fire detection and fire alarm systems - Power supply equipment respectively. Networked systems are evaluated by ensuring that each control panel connected to the network can operate as a stand alone unit, in the event of failure of the network connections, and that failure of a control panel will not affect other control panels on the network. LPCB is now accepting products for approval to EN 54-13: 2005 Compatibility assessment for system components which is applicable to the EU market. Note: Since LPCB uses national and international standards for the listing of products, in some instances, the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Control Equipment Limited


Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458651 Fax: +44 (0)1384 458972 E-mail: celsales@controlequipment.co.uk Website: www.controlequipment.com
Certificate No: 018b to LPS 1054-1 Certificate No: 018d to LPS 1054-1

14

12 Sep 2011

PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS
Certificated Products Precept fire alarm system Comprising the following products: Control Equipment Limited Precept 2, 4, 8, 16 and 32 zone control and indicating equipment. Apollo Fire Detectors Limited 55000-100 grade 1 rate of rise heat detector (45681-200 base) 55000-200 ionization smoke detector (45681-200 base) 55000-300 photoelectic smoke detector (45681-200 base) 53531-221 grade 1 rate of rise heat detector (45681-007 base) continued 53541-151 ionization smoke detector (45681-007 base) 53541-200 photoelectric smoke detector (45681-007 base) 55000-101 grade 2 rate of rise heat detector (45681-200 base) 55000-102 grade 3 rate of rise heat detector (45681-200 base) 55000-103 range 1 rate of rise heat detector (45681-200 base) 55000-104 range 2 rate of rise heat detector (45681-200 base) 55000-210 integrating ionization smoke detector (45681-200 base) Hochiki Corporation DFE-60 grade 2 fixed temperature heat detector (YBF-RL/4H5 base) DFE-90 range 1 fixed temperature heat detector (YBF-RL/4H5 base) DCC-1EL grade 1 rate of rise heat detector (YBF-RL/4H5 base) DCC-2EL grade 2 rate of rise heat detector (YBF-RL/4H5 base) DCC-R1EL range 1 rate of rise heat detector (YBF-RL/4H5 base) Hochiki Europe SLK-E photoelectric smoke detector (YBF-RL/4H5 base) SIH-E ionization smoke detector (YBF-RL/4H5 base) KAC Alarm Company Limited KR72 manual call point. Photain Controls Limited ISD-P91 ionization smoke detector PRR-P91 grade 1 rate of rise heat detector PHD-P90 range 1 fixed temperature heat detector Signature Industries - Clifford and Snell Alarms. MCP/R/F manual call point MCP/R/S manual call point System Sensor, St. Charles, Illinois, USA. 1151E ionization smoke detector (B401 base) 2151E photoelectric smoke detector (B401 base) Discovery fire alarm system Comprising the following products: Control Equipment Limited Discovery analogue addressable control and indicating equipment Apollo Fire Detectors Limited 55000-400 grade 2 analogue temperature monitor 55000-420 grade 2 analogue temperature monitor 58000-400 Discovery temperature monitor 55000-600 analogue photoelectric smoke monitor 55000-620 analogue photoelectric smoke monitor 58000-600 Discovery optical smoke monitor 55000-500 analogue ionisation smoke monitor 55000-520 analogue ionisation smoke monitor 58000-500 Discovery ionisation smoke monitor 58000-700 Discovery multisensor monitor 55000-900 surface and flush mounted manual call point 55000-910 flush mounted manual call point 55000-950 waterproof addressable manual call point 58000-900 flush and surface mounted manual call point 58000-910 flush mounted manual call point 58000-920 surface mounted manual call point 55000-700 XP95 short circuit isolator 45681-321 XP95 negative isolating base 45681-210 XP95 addressable mounting base 018d/01 LPCB Ref. No. 018b/S1

12 Sep 2011

15

PART 1: SECTION 2
FIRE DETECTION AND ALARM SYSTEMS

Notifier Fire Systems by Honeywell


Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 154e to LPS 1054: Issue 2.1 Certificated Products Notifier NFS2-8 Fire Alarm System Comprising the following products: Notifier Fire Systems Ltd 124-345-002 NFS2-8, 2 Zone Conventional Control and Indicating Equipment 124-345-004 NFS2-8, 4 Zone Conventional Control and Indicating Equipment 124-345-008 NFS2-8, 8 Zone Conventional Control and Indicating Equipment Morley-IAS Fire Systems ECO 1002 Photoelectric smoke and heat detector ECO 1003 Photoelectric smoke detector ECO 1004T High Temperature 78C heat detector class BS ECO 1005 Heat detector class A1R ECO 1005T Fixed temperature heat detector class A2S KAC Alarm Company Ltd MCP1A-Rxxxxx Indoor/outdoor surface/flush mounting conventional manual call point NS4/R Sounder 4 tone wall mounting conventional (red) NS4/W Sounder 4 tone wall mounting conventional (white) NS14/R Sounder 14 tones wall mounting conventional (red) NS14/W Sounder 14 tones wall mounting conventional (white) LPCB Ref. No. 154e/S1

UTC Fire & Security (Africa) trading as Ziton


Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa Tel: +27 21 5066000 Fax: +27 21 5066100 Website: www.utcfireandsecurity.com UK Sales enquiries: Ziton Limited Tel: +44 (0)1908 281981 Fax: +44 (0)1908 282554

Certificate No: 092f to LPS 1054 Certificated Products ZP5 Mark 5 analogue addressable fire alarm system Comprising the following products: ZP5 Mark 5 control and indicating equipment 092e/01 ZP710-2 analogue ionisation smoke detector (ZP7-SB1 base) 092n/01 ZP730-2 analogue optical smoke sensor (ZP7-SB1 base) 092n/02 ZP720-3 grade 1 analogue heat sensor (ZP7-SB1 base) 092p/01 ZP785-2 addressable flush and surface mounted call point 092d/01 Comprising of the following products: ZP3 analogue addressable control and indicating equipment 092h/01 ZP710-2 analogue addressable ionisation smoke detector 092n/01 ZP730-2 analogue addressable optical smoke detector 092n/02 ZP720-3 analogue addressable grade 1 heat detector 092p/01 ZP785-2 addressable flush and surface mounted manual call point 092d/01 ZP760-2 short circuit isolator 092j/01 LPCB Ref. No. 092f/S1

ZP3 analogue addressable fire alarm system

092f/S2

16

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT Control and Indicating Equipment (CIE) is a component of a fire detection and alarm system through which other components may be connected to it such as detectors, manual call points, sounders, routing equipment, voice alarm equipment and fire protection equipment. It is supplied with power from power supply equipment which may be housed within the CIE enclosure or a separate enclosure. CIE is used to receive and send out signals that are related to fire. CIE also monitors the system for faults (short and open circuit or power supply faults) and indicates the status of the fire detection and alarm system. CIE is designed to meet a European standard such as EN 54-2 or international standard such as ISO 7240-2 has certain options with requirements. For example, it may be designed to provide a signal to fire protection equipment or have dependencies on more than one alarm signal. Some CIEs have other functions which are not specified in the standard. These additional features are normally assessed such that they do not jeopardise compliance. The choice of CIE is dependant on the specific applications as recommended in the application guidelines for a specific job or building. Some CIEs have associated repeaters or mimic panels. These are normally used to repeat the indications given on the main CIE and sometimes they have control functions such as silencing sounders. There are no published standards that these repeaters or mimics can be tested against. This section lists Control and Indicating Equipment, and power supply equipment approved for use in fire detection and fire alarm systems in buildings. Repeaters or mimics that are listed in this section are only approved with their associated CIE and are subjected to the same environmental tests as the CIE. The initial approval and continued approval processes of this type of equipment is outlined in scheme document SD040. Products listed in this section have been approved to: EN 54-2: 1997 Control and Indicating Equipment; EN 54-2: 1997 + A1: 2006 Control and Indicating Equipment; EN 54-4: 1997 Power supply equipment; EN 54-4: 1997 + A1: 2002 and A2: 2006 Power supply equipment; ISO 7240-2: 2003 Control and Indicating Equipment; ISO 7240-4: 2003 Power supply equipment; Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-2: 1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that control and Indicating Equipment are certificated to EN 54-2: 1997 + A1: 2002 2. EN 54-4: 1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that power supply equipment are certificated to EN 54-4: 1997 + A1: 2002 and A2: 2006. 3. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly. 4. Where the Control and Indicating Equipment is of modular construction, and the use of certain modules (or printed circuit boards PCBs) is optional, these are listed with the applicable equipment.

12 Sep 2011

17

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Advanced Electronics Limited


34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0) 1226 737 465 Fax: +44 (0) 1226 737 469 E-mail: ithompson@advel.co.uk Website: www.Advel.co.uk
Certificate No: 018c to EN 54:Part 2 and 4: 1997 Certificated Products Mx-1002 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone Expansion board C1652 5A Power supply board C1631 Repeater interface board (option) Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs LPCB Ref. No. 018c/02

Mx-1004

018c/03

Mx-1008

018c/04

Mx-1016

018c/05

Mx-1032

018c/06

18

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface board LPCB Ref. No. 018c/R01

Mx-1108

Mx-1116

018c/R02

Mx-1132

018c/R03

AMPAC Europe Limited


Unit 18 Networkcentre, Yorkshire Way, Westmoor Park, Doncaster DN3 3GW, United Kingdom Tel: +44 (0)1302 833522 Fax: +44 (0)1302 835021 E-mail: info@ampac.net Website: www.ampac.net
Certificate No: 952a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment. Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit Zone Indicator & LCD Assembly (8210) LPCB Ref. No. 966a/01

Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. LoopSense 8281-0205 Two loop, 32 Zone analogue addressable control and indicating equipment. Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 8210-0001 BRD82LSD ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit 2nd loop activation Key Loop Activation Board Zone Indicator & LCD Assembly (8210) 966a/02

12 Sep 2011

19

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. LPCB Ref. No.

AMPAC Technologies PTY Ltd


7 Ledgar Road, Balcatta 6021, Australia Tel: +618 (9242) 3333 Fax: +618 (9242) 3334 E-mail: info@ampac.net Website: www.ampac.net
Certificate No: 966a to EN54-2: + A1 and EN54-4: A1+ A2 Certificated Products LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment. Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit Zone Indicator & LCD Assembly (8210) LPCB Ref. No. 966a/01

LoopSense 8281-0205

Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Two loop, 32 Zone analogue addressable control and indicating equipment. Incorporating the following units: BRD82MBA BRD82ZICC PSU2397 8210-0001 BRD82LSD ASS82ZICC Main Termination Board Zone Interface & Control Card Power Supply Unit 2nd loop activation Key Loop Activation Board Zone Indicator & LCD Assembly (8210)

966a/02

Certificated with the following options with requirements from EN54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

20

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delay to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.12.3 Dependencies on more than one alarm signal Type C 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each addressable point 10 Test condition Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. LPCB Ref. No.

Application Solutions (Safety & Security) Ltd


Unit 17 Cliffe Industrial Estate, East Sussex BN8 6JL, United Kingdom Tel: +44 (0) 1273 405411 Fax: +44(0) 1273 405415 E-mail: sales@asl-control.co.uk Website: www.asl-control.co.uk
Certificate No: 1043a to EN 54-16: 2008 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ASL Rack mount voice alarm system Incorporating the following modules: VAR8-ACU(EN54) Network master 8x8 router VAR4(EN54) Standalone 4x4 router VAR12(EN54) Standalone 12x12 router VAR20(EN54) Standalone 20x20 router VAR-NIA Network Interface Adaptor VAR8 Optional modules: VAR-ANIC Network interface for VAR8(EN54), VAR8-E(EN54) and VAR8-ACU(EN54) X400 Amplifier frame: X400 Amplifier frame for housing MX series amplifiers MX series amplifiers: MX100 00W Amplifier MX200 200W Amplifier MX400 400W Amplifier Power supply: BPC130 130AH Output power supply BDIST Battery distribution terminals MDIST Main distribution panel Optional modules: FMS5 Zoneable Firemans remote microphone - 5 buttons FMS10 Zoneable Firemans remote microphone - 10 buttons FMS20 Zoneable Firemans remote microphone - 20 buttons EMS01 Emergency microphone and accessible Mimic display for routers Certified with the following options with requirements from EN 54 Part 16: 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 12 Emergency microphone(s) 13.14 Redundant power amplifiers LPCB Ref. No. 1043a/01

12 Sep 2011

21

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Bardic by Honeywell
140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United Kingdom Tel: +44 (0) 116 246 2212 Fax: +44 (0) 116 246 2210 Website: www.bardic.co.uk
Certificate No: 154d to EN 54-2: 1997, EN 54-4: 1997 Certificated Products Bardic Zircon 2 Zone conventional controls and indicating equipment Including the following versions: 002-509-229 Language region 2, black & grey 4 Zone conventional controls and indicating equipment Including the following versions: 002-509-249 Language region 2, black & grey 8 Zone conventional controls and indicating equipment Including the following versions: 002-509-289 Language region 2, black & grey Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition Certificate No: 154g-(cl-3) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products Zircon 2 Zone Zircon 4 Zone Zircon 8 Zone 002-509-229 Bardic Zircon, 2 zone, region 2, black grey 002-509-249 Bardic Zircon, 4 zone, region 2, black grey 002-509-289 Bardic Zircon, 8 zone, region 2, black grey Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition LPCB Ref. No. 154g/06 154g/07 154g/08 LPCB Ref. No. 154d/09

Bardic Zircon

154d/10

Bardic Zircon

154d/11

Biamp Systems Corporation


9300 S.W. Gemini Drive, Beaverton, Oregon 97008, United States Tel: +1 503 718 9212 Fax: +1 503 626 0281 Website: www.biamp.com
Certificate No: 977a to EN 54-16: 2008

22

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Vocia VACIE Voice Alarm Control and Indicating Equipment Incorporating: LSI-16 / LSI-16e Life Safety Interface: 380-P630-90 LSI-16e Main Circuit Board 380-P632-90 LSI-16e Display Board 380-P675-90 IM-16 Input Card 380-P644-90 LSI-16e Power supply board VA-8600c Amplifier: 380-0646-90 VA-8600 AM-600c Amplifier Module 380-0601-90 VA-8600 NM-1 Network Module 380-0598-90 VA-8600 Back Plane Board 380-0599-90 VA-8600 Power Supply Board 380-0633-90 VA-8600 Capacitor Board(s) 380-0629-90 VA-8600 AC Inlet Board 380-0602-90 VA-8600 Display Board 380-P622-90 VA-8600 Device ID board 380-P800-90 VFOM-1 Voice Fail Over Module WS-4 (EWS-4) Paging Microphone: 380-P625-90 WS Main Board 380-P676-90 Switch Board configured as 700-P676 WS-4 (EWS-4) WS-10 (EWS-10) Paging Microphone: 380-P625-90 WS Main Board 380-P676-90 Switch Board configured as 700-P776 WS-10 (EWS-10) CI-1 Control Interface: 380-P669-90 CI-1 Circuit Board Certified with the following options with requirements from EN 54-16: 7.3 Audible warning 7.5 Phased evacuation 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 12 Emergency microphone 13.14 Redundant power amplifiers Note: The certification is conditional upon the Vocia VACIE being supplied with power from power supplies that meet the specifications detailed in the VOCIA Reference Guide, and comply with the requirements of EN 54-4. LPCB Ref. No. 977a/01

Carillion
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: 0116 246 2000 Fax: 0116 246 2300 Website: www.gent.co.uk
Certificate No: 042bc to EN 54-2: 1997+A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006 Certificated Products CP2-AMC Two loop analogue addressable control and indicating equipment (English language) Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 2434-861 Copper network card Scope of approval does not include the operation of the network card) LPCB Ref. No. 042bc/04

12 Sep 2011

23

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition CP4-AMC One to Four loop analogue addressable control and indicating equipment (English language) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 2434-674 Copper network card Note: Scope of approval does not include the operation of the network card) 7.8 7.11 8.3 9.5 10 CP4-72-AMC Certified with the following options with requirements from EN 54-2: Output to fire alarm devices Delays to outputs Fault signals from points Disablement of each address point Test condition 042bc/11 042bc/07 LPCB Ref. No.

One to Six loop analogue addressable control and indicating equipment (English Language) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 2434-674 Copper network card ( Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

CEAG
Postfach 11 16, D-59491 Soest, Germany Tel: +44 (0)1302 303397 Fax: +44 (0)1302 303220 Website: www.ceag.de
Certificate No: 714a to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products CF 3000 Analogue addressable 2 and 4 Loop control and indicating equipment LPCB Ref. No. 714a/01

24

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating the following units: ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options with requirements from EN54-2:1997: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition LPCB Ref. No.

Chubb Scurit
10 Avenue du Centaure, B.P.38408-95806, Cergy-Pontoise Cedex, France Tel: +33 1 30173737 Fax: +33 1 30173707 Website: www.chubbsecurite.com
Certificate No: 747a to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products Control Master 1000M-M Control Master 1000M-S 4 loop analogue addressable control indicating equipment (Medium enclosure) 4 loop analogue addressable control indicating equipment (Small enclosure) Incorporating the following units: CE00504 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00513 4 alarm zone control and indicating module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator CE00514 16 fire protection zone control and indicating module CE00503 2 Loop System sensor interface CE00520 2 Loop Apollo interface Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 loop analogue addressable control indicating equipment (Medium enclosure) 2 loop analogue addressable control indicating equipment (Small enclosure) Incorporating the following units: CE00504 Main CPU LPCB Ref. No. 747a/01 747a/01

Control Master 1020 M Control Master 1020 S

747a/02 747a/02

12 Sep 2011

25

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products CE00505 Main board display CE00506 Connection board CE00490 100W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator CE00513 4 alarm zone control and indicating module CE00514 16 fire protection zone control and indicating module Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1 loop, analogue addressable control indicating equipment Incorporating the following units: CE00510 Main CPU CE00505 Main board display CE00506 Connection board CE00490 100W PSU and as optional modular units: CE00508 16 Zone LED module CE00436A 4 Way sounder board CE00437A 8 Way sounder board CE00507 32 Zone LED module CE00435A Lon high integrity isolator CE00513 4 alarm zone control and indicating module CE00514 16 fire protection zone control and indicating module Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Remote unit Incorporating the following units: CE00509 Display board CE00484B Main board CE00489 40 W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00447 2 way network interface CE00446 4 way network interface CE00435A Lon high integrity isolator CE00513 4 alarm zone control and indicating module CE00514 16 Fire protection zone control and indicating module Control master 1000R-M Remote unit Incorporating the following units: CE00509 Display board CE00484B Main board CE00490 100 W PSU and as optional modular units: CE00508 16 Zone LED module CE00507 32 Zone LED module CE00513 4 alarm zone control and indicating module CE00447 2 Way network interface CE00446 4 Way network interface CE00435A Lon high integrity isolator CE00514 16 fire protection zone control and indicating module 747a/R02 LPCB Ref. No.

Control Master 1010S

747a/03

Control master 1000R-S

747a/R01

The following repeaters and the remote units are approved for use with the Control Master 1000 range of control and indicating equipment (incorporating 1020 and 1010):

26

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
RS Repeater 747a/R03 RS Repeater with LCD display 747a/R04 Lon Repeater with LCD display 747a/R05 Remote unit 747a/E01 Incorporating the following units: CE00503 2 Loop System sensor interface CE00489 40W PSU and as optional modular units: CE00490 100W PSU CE00435A Lon high integrity isolator

Computionics Limited (Trading as C-Tec)


Stephens Way, Goose Green, Wigan, Lancashire WN3 6PH, United Kingdom Tel: +44 (0)1942 322744/42444 Fax: +44 (0)1942 829867 E-mail: sales@C-tec.co.uk Website: www.c-tec.co.uk
Certificate No: 176a to EN 54: Part 2 and 4: 1997 Certificated Products CFP 2 CFP 4 CFP 8 Conventional 2 zone control and indicating equipment Conventional 4 zone control and indicating equipment Conventional 8 zone control and indicating equipment LPCB Ref. No. 176a/01 176a/02 176a/03

Certificated with the following options from BS EN 54 Part 2: 7.8 Output to sounders 7.11 Delays to outputs 10 Test condition

Certificate No: 176b to EN 54-2: 1997 + A1: 2006 + A2: 2007 and EN 54-4: 1997 + A1: 2002 Certificated Products XFP502/H 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN 54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note: 1) Scope of approval does not include the operation of the network functionality. 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501199 Display board "keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment LPCB Ref. No. 176b/01

XFP502K/H

176b/01

12 Sep 2011

27

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note: 1) Scope of approval does not include the operation of the network functionality. 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Note: 1) Scope of approval does not include the operation of the network functionality. 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol + Keyswitch, metal housing Incorporating the following units: LPCB Ref. No.

XFP502/X

176b/02

XFP502/X/CON

176b/02

XFP502K/X

176b/02

XFP502K/X/CON

176b/02

28

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop, main motherboard SPF0501200 Display board "Keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop metal case, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter LPCB Ref. No.

XFP501/H

176b/03

XFP501K/H

176b/03

XFP501/X

176b/04

12 Sep 2011

29

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality. 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housing + Keyswitch Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol + Keyswitch, metal housing Incorporating the following units: SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501199 Display board "Keyswitch display" Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501102 XFP Hochiki 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 LPCB Ref. No.

XFP501/X/CON

176b/04

XFP501K/X

176b/04

XFP501K/X/CON

176b/04

XFP501E/H

176b/05

30

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 7.11 Output to fire alarm device(s) Delays to the actioning of outputs fire alarm devices and fire routing equipment Dependencies on more than one alarm signal - Type A Dependencies on more than one alarm signal - Type B Dependencies on more than one alarm signal - Type C Alarm counter Fault signals from points Disablement of each address point Test condition LPCB Ref. No.

XFP501EK/H

7.12.1 7.12.2 7.12.3 7.13 8.3 9.5 10 Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housing + Keyswitch Incorporating the following units: SPF0702480 Switch mode power supply board SPF1501102 XFP Hochiki 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housing + Keyswitch Incorporating the following units:

176b/05

XFP501E/X

176b/06

XFP501E/X/CON

176b/06

XFP501EK/X

176b/06

12 Sep 2011

31

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products SPF0702480 Switch mode power supply board SPF1501101 XFP Apollo 1 loop, main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality One Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, Plastic housing Incorporating the following units: SPF0702480 Switch mode power supply board SPF1501101 XFP Apollo 1 loop, Main motherboard Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.12.3 Dependencies on more than one alarm signal - Type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Notes: 1) Scope of approval does not include the operation of the network functionality LPCB Ref. No.

XFP501KE/X/CON

176b/06

Certificate No: 176c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 12094-1: 2003 Certificated Products EP203 Conventional three zone class A extinguisher control panel Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Incorporating as modular units: EP210S Remote Status Unit Surface Mount optional (See Note 1) EP211 Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals Certified with the following options with requirements from EN-54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing Main extinguisher control External relay interface Power supply unit EP214 terminator LPCB Ref. No. 176c/01

32

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products equipment 7.13 Alarm counter 10 Test condition Conventional three zone class A extinguisher control panel Incorporating the following units: SPF0000203 SPF0000212 SPF0003613 SPF0000214 Incorporating as modular units: EP210S Remote Status Unit Surface Mount optional (See Note 1) EP211 Economy Status Unit optional (See Note 1) Certified with the following options with requirements from EN 12094-1:2003 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals Certified with the following options with requirements from EN-54-2:1997 7.8 Output to fire alarm device(s) 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.13 Alarm counter 10 Test condition Notes: 1) Optional Remote Status Unit part No. EP21OS & Economy Status Unit part No. EP211 are not certified as meeting the requirements of the standards specified. 2) Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5C to +40C. Main extinguisher control External relay interface Power supply unit EP214 terminator LPCB Ref. No.

EP203/CON

176c/01

Control Equipment Limited


Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458651 Fax: +44 (0)1384 458972 E-mail: celsales@controlequipment.co.uk Website: www.controlequipment.com
Certificate No: 018a to BS 5839: Part 4. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU. Certificated Products Precept 2 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1440 Display Board 4 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1441 Display Board 8 zone control and indicating equipment Incorporating as modular units C1427 Motherboard C1462 Display Board 16 zone control and indicating equipment Incorporating as modular units C1425 Motherboard LPCB Ref. No. 018a/01

Precept

018a/02

Precept

018a/03

Precept

018a/04

12 Sep 2011

33

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Precept C1426 Display Board 32 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board C1464 Display Board 2 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1440 Display Board 4 zone control and indicating equipment Incorporating as modular units C1423 Motherboard C1441 Display Board 8 zone control and indicating equipment Incorporating as modular units C1427 Motherboard C1462 Display Board 16 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board 32 zone control and indicating equipment Incorporating as modular units C1425 Motherboard C1426 Display Board C1464 Display Board Certificate Nos. 018a and 018c: Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Certificate Nos. 018c/02-06: Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition LPCB Ref. No. 018a/05

Series 600

018a/06

Series 600

018a/07

Series 600

018a/08

Series 600

018a/09

Series 600

018a/10

Certificate No: 018n to EN 54-4: 1997 + A1: 2002 + A2: 2006

Power Supply Unit


Certificated Products 2605467 Fireclass 1.9A Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels LPCB Ref. No. 018n/01

Certificate No: 018c to EN 54: Part 2 and 4: 1997 Certificated Products Discovery 4 loop analogue addressable control and indicating equipment Incorporating: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230 Vac power supply control card A1599 Printer board 2 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board LPCB Ref. No. 018c/01

Precept En2 (2605-100)

018c/02

34

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products C1628 Display board C1631 Repeater interface board (option) 4 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 8 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 16 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 32 zone conventional control and indicating equipment Incorporating as modular units:C1627 Mother board C1629 Display board C1631 Repeater interface board (option) C1632 16 Zone Expansion board C1652 5A Power supply board 8 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 16 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 32 zone conventional repeater unit Incorporating as modular units:C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificate Nos. 018a and 018c: Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Certificate Nos. 018c/02-06: Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition LPCB Ref. No. 018c/03

Precept En4 (2605-101)

Precept En8 (2605-102)

018c/04

Precept En16 (2605-103)

018c/05

Precept En32 (2605-104)

018c/06

Precept En8 (2605-110)

018c/R01

Precept En16 Repeater (2605-111)

018c/R02

Precept En32 Repeater (2605-112)

018c/R03

12 Sep 2011

35

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Cooper Industries Inc


Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 303303 Fax: +44 (0)1302 367155 E-mail: sales@cooper-ls.com Website: www.cooper-ls.com UK Sales: Menvier & JSB Tel: +44 (0)1302 303202 Fax: +44 (0)1302 367155 E-mail: enquiries@cooper-ls.com Website: www.cooper-ls.com

UK Sales: Tel: +44 (0)1594 541900 Fax: +44 (0)1594 541910 E-mail: sales@cooperfire.co.uk Website: www.cooperfire.co.uk

Certificate No: 714a to EN 54 Part 2 and 4 :1997 Certificated Products CF3000 Analogue addressable 2 and 4 loop Control and indicating equipment Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6 Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 and 4 loop control and indicating equipment Incorporating the following units: ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment LPCB Ref. No. 714a/01

DF6000

714a/01

36

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Output to automatic fire protection equipment Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 and 4 Loop control and indicating equipment Incorporating the following units: ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Analogue addressable 2 Loop control and indicating equipment Incorporating the following units: PR202-50-2209 Power supply board PR202-50-2206 Main motherboard PR202-50-2205 Display board Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition 7.10 7.11 LPCB Ref. No.

FX6000

714a/01

CF2000

714a/02

Cooper Lighting and Safety Ltd


Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: 01302 303397 Fax: 01302 303251 Website: www.cooper-Is.com
Certificate No: 714h to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products CF3000 Intelligent analogue addressable 2 and 4 loop control and indicating equipment Incorporating the following units: ADF6 Back Assembled back box LPCB Ref. No. 714h/01

12 Sep 2011

37

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products YPCB2153 YPCB2147 YPCB2148 ADF6Screen YPCB2185 ADF6 DISPCOVER ADF6FACIA ADF6PRINTDOOR BAT-NP12-12 ADF6HINGE ADF6OPFACIA ADF6PRINTER YPCB2187 Motherboard PCB PSU PCB 2 Loop Card (2 off) Touch Screen Complete Display + Micro PCB Display PCB Cover Front Moulding Printer Door Moulding Batteries (2 off) Door Hinges Optional Anti Tamper Cover Printer Fire Brigade Interface LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment (Type A) 7.10.2 Output to automatic fire protection equipment (Type B) 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal (Type C) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. 2. DF6000

The scope of approval does not include the network functionality. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 714h/01

Intelligent analogue addressable 2 and 4 loop control and indicating equipment Incorporating the following units: ADF6 Back YPCB2153 YPCB2147 YPCB2148 ADF6Screen YPCB2185 ADF6 DISPCOVER ADF6FACIA ADF6PRINTDOOR BAT-NP12-12 ADF6HINGE ADF6OPFACIA ADF6PRINTER YPCB2187 Assembled back box Motherboard PCB PSU PCB 2 Loop Card (2 off) Touch Screen Complete Display + Micro PCB Display PCB Cover Front Moulding Printer Door Moulding Batteries (2 off) Door Hinges Optional Anti Tamper Cover Printer Fire Brigade Interface

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment (Type A) 7.10.2 Output to automatic fire protection equipment (Type B) 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal (Type C) 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. 2.

The scope of approval does not include the network functionality. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

38

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Detector Electronics Corporation


Minneapolis, Minesota 55438, United States Tel: +001 952 946 6488 E-mail: detronics@detronics.com Website: www.det-tronics.com
Certificate No: 973c to EN 54-2: 1997 + A1: 2006 Certificate No: 973d to EN 54-2: 1997 + A1: 2006 + EN12094-1: 2003 Certificated Products EQ5400D Single loop eight zone addressable control and indicating equipment IQ3150 Controller Detection panel EQ2220 (GFM) LTM EQ3730 (EDIO) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Main controller Detection panel Ground Fault Monitor Lon termination module Enhanced Discrete Input/Output (SIL only) LPCB Ref. No. 973c/01

EQ5400R

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 10 Test condition Single loop eight zone addressable control and indicating equipment Incorporating as modular units: EQ3150 Controller Detection panel Routing panel EQ2220 (GFM) LTM EQ3730 (EDIO) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Main controller Detection panel Routing panel Ground Fault Monitor Lon termination module Enhanced Discrete Input/Output (SIL only)

973c/02

EQ5400E

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 10 Test condition Single loop eight zone addressable control and indicating equipment and two

973d/01

12 Sep 2011

39

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products extinguishing zone class B electrical automatic control and delay devices Incorporating as modular units: EQ3150 Controller Detection panel Routing panel Extinguishing panel EQ2220 (GFM) LTM EQ3730 (EDIO) and as optional modular units: EQ3710 (AIM) EQ3720 (RM) Model EQ22EM (IDCSC) Model EQ25EM (SAM) Model EQ24EM (NE) Model EQ24EM (PLR) EQ3810 (PDM) 750XCXH-24D Analogue Input Module Relay Module Initiating Device Circuit - Short Circuit Signal Audible Module Network Extender Physical Layer Repeater Power Distribution Module Magnecraft relay module Main controller (Redundant) Detection panel Routing panel Extinguishing panel Ground Fault Monitor Lon termination module Enhanced Discrete Input/Output (SIL only) LPCB Ref. No.

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 10 Test condition Certified with the following options with requirements from EN 12094-1: 4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.21 Control of flooding time 4.23 Manual only mode

Fike Safety Technology Ltd


Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom Tel: +44 (0)1633 865558 Fax: +44 (0)1633 866656 E-mail: fstinfo@fike.com Website: www.fikesafetytechnology.co.uk
Certificate No: 331q to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products 505-0002 TWINFLEXpro, 2 Zone conventional control and indicating equipment Incorporating: 10-0067 Main Processor Card. Certified with the following options from EN 54 Part 2: 7.8 7.10.1 7.11 7.12.1 8.3 10 Output to fire alarm devices Output type A to fire protection equipment Delays to outputs Type A dependency on more than one alarm signal Fault signals from points Test condition. LPCB Ref. No. 331q/06

40

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 505-0004 TWINFLEXpro, 4 Zone conventional control and indicating equipment Incorporating: 10-0067 Main Processor Card. Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.10.1 Output type A to fire protection equipment 7.11 Delays to outputs 7.12.1 Type A dependency on more than one alarm signal 8.3 Fault signals from points 10 Test condition. TWINFLEXpro, 8 Zone conventional control and indicating equipment Incorporating: 10-0067 Main Processor Card 10-0087 4 Zone expansion card. Certified with the following options from EN 54 Part 2: 7.8 7.10.1 7.11 7.12.1 8.3 10 Output to fire alarm devices Output type A to fire protection equipment Delays to outputs Type A dependency on more than one alarm signal Fault signals from points Test condition. LPCB Ref. No. 331q/07

505-0008

331q/08

Firelite by Honeywell
Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 1444 230 300 Fax: +44 1444 230 888 E-mail: sales@morleyias.co.uk
Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products FLS2-8 2 Zone 002-475-122 Language region 1, light grey 002-489-122 Language region 1, light grey, English manual 002-475-222 Language region 2, light grey 002-489-222 Language region 2, light grey, English manual 002-475-142 Language region 1, light grey 002-489-142 Language region 1, light grey, English manual 002-475-242 Language region 2, light grey 002-489-242 Language region 2, light grey, English manual 002-475-182 Language region 1, light grey 002-489-182 Language region 1, light grey, English manual 002-475-282 Language region 2, light grey 002-489-282 Language region 2, light grey, English manual Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit LPCB Ref. No. 154g/06

FLS2-8 4 Zone

154g/07

FLS2-8 8 Zone

154g/08

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs

12 Sep 2011

41

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
7.12.2 8.9 10 Dependency on more than one alarm signal: Type B Output to fault warning routing equipment Test condition

FIREX Protection System Technology Ltd


28-38 Desborough Street, High Wycombe, Bucks, United Kingdom Tel: +44 (0)1494 601077 Fax: +44 (0)1494 601011 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 548j to EN 54-2: 1997 and EN54-4: 1997 Certificated Products FX200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.908.312 Zone indication board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power Supply unit F2.910.093 Mains filter R150 Transformer CGM12864 Alphanumeric Display F2.828.630a Printer board (option) Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition LPCB Ref. No. 548j/01

FX1

548j/02

FX2

548j/03

FX4

548j/04

FX8

548j/05

FX16

548j/06

42

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries E-mail: gent.export@honeywell.com

Certificate No: 042x to EN 54: Parts 2 & 4: 1997 Certificate No: 042bb to EN 54-2:1997 and EN 54-4: 1997 Certificate No: 042bc to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products AS-2000 Two loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-824 Power supply 2434-710 Loop Processor Card 2434-833 Master Control Card 2434-825 Optical Network Card* 2434-821 Message Store Card* 2434-822 Mother board 2434-835 H.M.I 2434-840 Cold fire card 2434-796 Addressable speaker card (Optional Card)* 2434-826 Addressable daughter speaker card (Optional Card)* 2434-780 Audio Input Card (Optional Card)* 2434-781 Audio Output Card (Optional Card)* Scope of approval does not include the functionality of the network card and optional voice alarm system cards) Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Single loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Spanish Language Variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Portuguese Language Variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) LPCB Ref. No. 042bb/01

Nano-24

042bc/01

Nano-24-SP

042bc/02

Nano-24-PO

042bc/03

12 Sep 2011

43

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Two loop analogue addressable control and indicating equipment (English language) Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 4374-162 Text Membrane (Spanish) 4374-163 Text Membrane (Portuguese) 2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Two loop analogue addressable control and indicating equipment (Portuguese language variant) Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 4374-162 Text Membrane (Spanish) 4374-163 Text Membrane (Portuguese) 2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition Two loop analogue addressable control and indicating equipment (Spanish language variant) Incorporating as modular units: 2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 4374-162 Text Membrane (Spanish) 4374-163 Text Membrane (Portuguese) 2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (English language) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module LPCB Ref. No.

Vigilon Compact-24-N

042bc/04

Vigilon Compact-24-PO

042bc/05

Vigilon Compact-24-SP

042bc/06

Vigilon VIG1-24

042bc/07

44

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (English language variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (Portuguese language variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (Spanish language variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) LPCB Ref. No.

Vigilon VIG1-24-NP

042bc/08

Vigilon VIG1-24-PO

042bc/09

Vigilon VIG1-24-SP

042bc/10

12 Sep 2011

45

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Six loop analogue addressable control and indicating equipment (English Language) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Six loop analogue addressable control and indicating equipment (Portuguese Language Variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Six loop analogue addressable control and indicating equipment (Spanish Language Variant without printer module) Incorporating as modular units: 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 4374-158 Text Membrane (Spanish) 4374-159 Text Membrane (Portuguese) 2434-674 Copper network card (Note: Scope of approval does not include the operation of the network card) LPCB Ref. No.

Vigilon VIG1-72

042bc/11

Vigilon VIG1-72-PO

042bc/12

Vigilon VIG1-72-SP

042bc/13

46

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition 1 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 2 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 4 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition 8 zone conventional control and indicating equipment Certified with the following options from EN 54 Part 2: 1997 7.8 Output to fire alarm devices 7.11 Delays of actioning to outputs to fire alarm routing equipment 10 Test condition LPCB Ref. No.

13270-01

042x/01

13270-02

042x/02

13270-04

042x/03

13270-08

042x/04

Global System Technology Plc


Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United Kingdom Tel: +44 (0)1283 225 478 Fax: +44 (0)1283 222 039 E-mail: info@gst.uk.com Website: www.gst.uk.com
Certificate No: 548j to EN 54: Parts 2 and 4 :1997 Certificated Products GST 200 Intelligent 1 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power supply unit F7.908.312 Zone indication board CGM12864 Alphanumeric display F2.910.093 Mains filter R150 Transformer F2.828.630a Printer board (option) Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: LPCB Ref. No. 548j/01

GST 101

548j/02

GST 102

548j/03

12 Sep 2011

47

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition LPCB Ref. No. 548j/04

GST 104

GST 108

548j/05

GST 116

548j/06

Certificate No: 548p-(cl-1) to EN 54-2: 1997 + A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006 Certificated Products GST200-2 Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829b Power supply unit F7.908.312d Zone indication and intervention board F7.820.1125 Loop board Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.1238 Indication board F7.820.1239 Loop board F7.820.1311 Power board F7.820.1312 ZCP board F7.820.1326 Keypad board F7.820.1237 Main board F7.820.1310 Mother board Incorporating as optional modular units: F7.820.1313 USB communication board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point LPCB Ref. No. 548p/01

GST-IFP8

548p/02

48

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products GST102A 10 Test condition 2 Zone conventional control and indicating equipment Incorporating the following modules: F7.843.399 Membrane F2.908.1719 Control board with integrated PSE F2.908.1722 Display board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 4 Zone conventional control and indicating equipment Incorporating the following modules: F7.843.400 Membrane F2.908.1718 Control board with integrated PSE F2.908.1721 Display board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 8 Zone conventional control and indicating equipment Incorporating the following modules: F7.843.401 Membrane F2.908.1675 Control board with integrated PSE F2.908.1720 Display board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 16 Zone conventional control and indicating equipment Incorporating the following modules: F7.843.402 Membrane F2.908.1724 Control board with integrated PSE F2.908.1676 Display board F7.820.1677 Expansion board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition LPCB Ref. No. 548p/03

GST104A

548p/04

GST108A

548p/05

GST116A

548p/06

Group 4 Securicor Plc


Manor Royal, The Manor, Crawley, West Sussex RH10 9UN, United Kingdom Tel: +44 (0)20 87707000 Fax: +44 (0)20 87722531 Website: www.g4s.com
Certificate No: 548j-(cl-1) to EN 54-2: 1997 and EN54-4: 1997 Certificate No: 548p-(cl-4) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products GS200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.908.312 Zone indication board LPCB Ref. No. 548j/01

12 Sep 2011

49

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power Supply unit F2.910.093 Mains filter R150 Transformer CGM12864 Alphanumeric Display F2.828.630a Printer board (option) Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829b Power supply unit F7.908.312d Zone indication and intervention board F7.820.1125 Loop board Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit LPCB Ref. No.

GS101

548j/02

GS102

548j/03

GS104

548j/04

GS108

548j/05

GS116

548j/06

GS200-2

548p/01

GSIFP8

Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.1238 Indication board F7.820.1239 Loop board F7.820.1311 Power board F7.820.1312 ZCP board F7.820.1326 Keypad board F7.820.1237 Main board

548p/02

50

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products F7.820.1310 Mother board LPCB Ref. No. Incorporating as optional modular units: F7.820.1313 USB communication board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn Sales Beijing: Tel: +86 (10) 6439 1866 Fax: +86 (10) 6439 1787

Sales Hong Kong: Tel: +852 2877 8566 Fax: +852 2511 8699

Certificate No: 548j to EN 54-2: 1997 & EN54-4: 1997 Certificated Products GST-200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.908.312 Zone indication board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power Supply unit F2.910.093 Mains filter R150 Transformer CGM12864 Alphanumeric Display F2.828.630a Printer board (option) Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: LPCB Ref. No. 548j/01

GST 101

548j/02

12 Sep 2011

51

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition LPCB Ref. No. 548j/03

GST 102

GST 104

548j/04

GST 108

548j/08

GST 116

548j/09

Certificate No: 548p to EN 54-2: 1997 + A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006 Certificated Products GST200-2 Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829b Power supply unit F7.908.312d Zone indication and intervention board F7.820.1125 Loop board Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.1238 Indication board F7.820.1239 Loop board F7.820.1311 Power board F7.820.1312 ZCP board F7.820.1326 Keypad board F7.820.1237 Main board F7.820.1310 Mother board Incorporating as optional modular units: F7.820.1313 USB communication board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.9.2 Alarm confirmation input from fire routing equipment 7.10.1 Output type A 7.10.2 Output type B 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal - Type A LPCB Ref. No. 548p/01

GST-IFP8

548p/02

52

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.12.2 Dependencies on more than one alarm signal - Type B 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition 2 Zone conventional control and indicating equipment Incorporating the following modules: F7.843.399 Membrane F2.908.1719 Control board with integrated PSE F2.908.1722 Display board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition 4 Zone conventional control and indicating equipment Incorporating the following modules: F7.843.400 Membrane F2.908.1718 Control board with integrated PSE F2.908.1721 Display board Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire routing equipment 7.11 Delays to outputs 10 Test condition LPCB Ref. No.

GST102A

548p/03

GST104A

548p/04

Haes Systems Limited


Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom Tel: +44 (0)1895 422066 Fax: +44 (0)1895 420603 E-mail: enquiries@haes-systems.co.uk Website: www.haes-systems.co.uk
Certificate No: 810a to EN 54-2: 1997+A1:2006 and EN 54-4: 1997+A1:2002+A2:2006 Certificated Products FBUS X-Y-Z 1 to 4 Loop analogue addressable and/or 4-20 Zone conventional control and indicating equipment Incorporating as modular units: FSB17 Main Display PCB FSB10 Expander PCB PSUFUSION-3A 3A Power Supply Control PCB PSULS100-36 36V 100W Lambda Power supply Module Cabinet size 340H x 460W x 120D mm and as optional modules: FSB18 FSB11 FSB10-E FSB12-32 FSB12-64 4 Way Conventional zone PCB 1 Loop Card Apollo protocol Bank Extender PCB 16 Way expansion LED PCB 48 Way expansion LED PCB LPCB Ref. No. 810a/01

FBUL X-Y-Z

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 9.5 Disablement of each addressable point 10 Test condition 1 to 8 Loop analogue addressable and/or 4-36 zone conventional control and indicating equipment Incorporating as modular units:

810a/02

12 Sep 2011

53

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products FSB17 Main Display PCB FSB10 Expander PCB PSUFUSION-5A 5A Power Supply Control PCB PSULS150-36 36V 150W Lambda Power supply Module Cabinet size 750H x 470W x 140D mm and as optional modules: FSB18 FSB11 FSB10-E FSB12-32 FSB12-64 4 Way Conventional zone PCB 1 Loop Card Apollo protocol Bank Extender PCB 16 Way expansion LED PCB 48 Way expansion LED PCB LPCB Ref. No.

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 9.5 Disablement of each addressable point 10 Test condition Note: 1. 2. Model name suffix X denote the LED display module type, Y denote the number of conventional zones and Z denote the number of loops. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

Honeywell Control Systems Ltd


Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: 01344 655609 Fax: 01344 655474 Website: www.honeywellbuildingsolutions.co.uk
Certificate No: 154g-(cl-1) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products XLS80e Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-538-101 XLS80e Basic Equipment Kit, Group 1 020-538-103 XLS80e Basic Equipment Kit, Group 3 020-538-104 XLS80e Basic Equipment Kit, Group 4 020-538-105 XLS80e Basic Equipment Kit, Group 5 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface LPCB Ref. No. 154g/01

54

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 020-479 020-648 020-579 Interface) 020-548 020-543 020-773 020-877 020-643 020-647-100 Panel RS485 Interface PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU PSU7A Status Indication Dual Transmission Path / Booster, PSU Interface Routing Termination Unit (DEOL) Extinguishing Interface Module M221-SI XLS80e-NI Fibre Optic Interface Kit XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e LPCB Ref. No.

Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-2L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 2 loop analogue addressable control and indicating equipment. 020-692 XLS80e-2L-1, 2 Loop, PSU3A, Group 1 020-692-103 XLS80e-2L-3, 2 Loop, PSU3A, Group 3 020-692-104 XLS80e-2L-4, 2 Loop, PSU3A, Group 4 020-692-105 XLS80e-2L-5, 2 Loop, PSU3A, Group 5 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 154g/01

12 Sep 2011

55

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 020-643 020-647-100 Panel XLS80e-NI Fibre Optic Interface Kit XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e LPCB Ref. No.

Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-4L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 4 loop analogue addressable control and indicating equipment. 020-693 XLS80e-4L-1, 4 Loop, PSU3A, Group 1 020-693-103 XLS80e-4L-3, 4 Loop, PSU3A, Group 3 020-693-104 XLS80e-4L-4, 4 Loop, PSU3A, Group 4 020-693-105 XLS80e-4L-5, 4 Loop, PSU3A, Group 5 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 XLS80e-NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 154g/01

56

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-6L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 6 loop analogue addressable control and indicating equipment. 020-694 XLS80e-6L-1, 6 Loop, PSU7A, Group 1 020-694-103 XLS80e-6L-3, 6 Loop, PSU7A, Group 3 020-694-104 XLS80e-6L-4, 6 Loop, PSU7A, Group 4 020-694-105 XLS80e-6L-5, 6 Loop, PSU7A, Group 5 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 XLS80e-NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 154g/01 LPCB Ref. No.

12 Sep 2011

57

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic XLS80e-8L Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. Fixed build 8 loop analogue addressable control and indicating equipment. 020-695 XLS80e-8L-1, 8 Loop, PSU7A, Group 1 020-695-103 XLS80e-8L-3, 8 Loop, PSU7A, Group 3 020-695-104 XLS80e-8L-4, 8 Loop, PSU7A, Group 4 020-695-105 XLS80e-8L-5, 8 Loop, PSU7A, Group 5 Incorporating the following as modular units: Enclosures: 020-040-002 Cover Kit Extended Moulded, Light / Grey 020-472-002 Backbox Kit Standard, Light Grey 020-473-002 Backbox Kit Extended, Light Grey 020-474-002 Backbox Kit Extended Deep, Light Grey 020-475-002 Backbox Kit Double Extended, Light Grey 020-476-002 Backbox Kit Double Extended Deep, Light Grey 020-480-102 Main Cover Kit, Light / Grey 020-481-002 Extension Cover Kit, Light / Grey 020-509-002 Backbox Extension Deep Assembly Light / Grey 020-621-002 256 Zone Extension Cover, Light / Grey 020-541-102 PSU7A / 78Ah Battery Enclosure Modules: 020-708-100 Extension Chassis with Printer Kit 020-644-009 Printer Assembly 020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module 020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module 020-612-100 Double Extended Chassis Kit 256 Zone 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588-100 Honeywell Dual Loop Interface Board, (LIB) 020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface 020-479 RS485 Interface 020-648 PSU3A 020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) 020-548 PSU7A Status Indication 020-543 Dual Transmission Path / Booster, PSU Interface 020-773 Routing Termination Unit (DEOL) 020-877 Extinguishing Interface Module M221-SI 020-643 XLS80e-NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic 154g/01 LPCB Ref. No.

58

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products LPCB Ref. No. Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. 002-467-002 Network Gateway Unit, (NGU) Honeywell Protocol Incorporating the following as modular units: 020-643 XLS80e- NI Fibre Optic Interface Kit 020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel 020-648 PSU3A Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit. 154g/NO1

XLS80e-NI

Honeywell International Inc


1500 West Dundee Road, Arlington Heights IL 60004, United States Tel: +1 847 797 4403 Fax: +1 847 797 3664
Certificate No: 262v-(cl-1) to EN 54-2: 1997 & EN 54-4: 1997 Certificated Products XLS1000 Control and indicating equipment Incorporating as modular units: 3-SSDC1-E Signature (Single), driver controller module 3-SDDC1-E Signature (Dual), driver controller module 3-AADC1-E System Sensor driver control module 3-EASC-E Edwards (Single) Analogue driver controller module 3-EADC-E Edwards (Dual) Analogue driver controller module 3-PPS/M-230-E Primary Power Supply 3-BPS/M-230-E Booster Power Supply 3-BBC/M-230-E Booster Battery Charger Power Supply 3-ASU Audio Source Unit 3-ASU/FT-E Audio Source Unit with Fire Fighter Telephone 3-ASUMX/100 100 minute extended audio memory card 3ASU/4 Audio Source Unit with 4 Local Rail Modules (LRM) slots 3-ZA20A 20 watt Zone Amplifier, Class A 3-ZA20B 20 watt Zone Amplifier, Class B 3-ZA40A 40 watt Zone Amplifier, Class A 3-ZA40B 40 watts Zone Amplifier, Class B 3-CPU3 Central Processor Unit EFM-2 Data Communications Filter 3-ZA95 95 watt Zone Amplifier, Class A 3-CAB7-E 7 Slot Cabinet 3-CAB14-E 14 Slot Cabinet 3-CAB21-E 21 Slot Cabinet 3-CAB7D(R)-E Door for 7 Slot Cabinet, (R) indicates red 3-CAB14D(R)-E Door for 14 Slot Cabinet, (R) indicates red 3-CAB21D(R)-E Door for 21 Slot Cabinet, (R) indicates red 3-RCC7R-E Small Remote Battery Cabinet 3-RCC14R-E Medium Remote Battery Cabinet 3-RCC21R-E Large Remote Battery Cabinet 3-LCD Liquid Crystal Display, user interface 3-BATSEN-E Remote battery cabinet interface, temperature sensing 3-BATSEN Remote battery cabinet interface 3-BATS Battery Shelf 3-RS485A Data Communication, Class A 3-RS485B Data Communication, Class B 3-RS232 Serial Communications Card (Printer, etc) 3-PSMON Primary Power Supply Monitor 3-IDC8/4 Initiating Device Circuits/NACS 3-24R 24, Red LPCB Ref. No. 262v/01

12 Sep 2011

59

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 3-24Y 24, Yellow 3-24G 24, Green 3-12RY Red-over-yellow pairs 3-12SR 12 Switches. Red 3-12SY 12 Switches. Yellow 3-12SG 12 Switches. Green 3-12/S1GY 12 Switches. Green over-yellow pairs 3-12/S1RY 12 Switches. Red over-yellow pairs 3-12/S2Y 24, Yellow, 12 Switches 3-12/S2R 24, Red, 12 Switches 3-6/3S1G2Y Green-over-yellow-over-yellow triads, 6 triads 3-6/3S1GYR Green-over-yellow-over-red triads, 6 triads 3-6/3S2RY Red-over-yellow-over-red triads, 6 triads 3-BBCMON Booster, Battery Charger Monitor 3-BPSMON Booster Power supply Monitor 3-LDSM Annunciator strip support module 3-LRMF Local Rail Module Filler 3-FTCU MB Fire fighter Telephone Control Unit MB 3-FTCU-E Fire fighter Telephone Control Unit Display 3-REMICP Remote Microphone, Panel 3-RCIC ASU Interconnect power and rail communication unit Repeater Incorporating as modular units: 3-RS485BA Remote Annunciator RS485 Communications. 3-ANNCPU3 Remote Annunciator CPU 3-LCDANN-E LCD Display and User Interface for Remote Annunciator 3-ANNSM Remote (repeater) Annunciator Support Module 3-REMICA Remote paging Microphone 3-24Y 24, Yellow 3-12/S1GY 12 Switches. Green over-yellow pairs 3-6ANN-E(R) Remote Annunciator Back Box, 6 slots, with Door (R) indicates red 3-10ANN-E(R) Remote Annunciator Back Box, 10 slots, with Door (R) indicates red Certified with the following options with requirements from EN 54 Part 2: 7.8 7.13 8.3 10 Output to fire alarm devices Alarm counter Fault Signals from points Test condition LPCB Ref. No.

XLS1000

262v/01

Notes: 1. Scope of approval does not include system compatibility.

Morley-IAS Fire Systems By Honeywell


Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@morleyias.co.uk Website: www.morley-ias.co.uk
Certificate No: 429a to EN 54: Part 2 and 4: 1997 Certificated Products ZX2e 1-2 loop analogue addressable control and indicating equipment Incorporating the following units: 124-206 Processor card 124-327 ZX2/5e 20 zone display 124-231 Apollo Discovery loop driver card 124-195 Hochiki loop driver 124-249-003 Morley IAS loop driver card 124-207-003 2A PSU 124-209-002 2 loop base card 124-196 230V filter card LPCB Ref. No. 429a/01

60

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products ZX5e 1-5 loop analogue addressable control and indicating equipment Incorporating the following units: 124-206 Processor card 124-327 ZX2/5e 20 zone display 124-205-002 3A PSU 124-330-001 60 zone extender 124-354 5 loop base card 124-231 Apollo Discovery loop driver card 124-195 Hochiki loop driver 124-249-003 Morley IAS loop driver card The ZX model range Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-2 loop analogue addressable control and indicating equipment Incorporating the following units: 124-206 Processor card 124-231 Apollo Discovery loop driver card 124-195 Hochiki loop driver card 124-329 320b/380b 20 zone display 124-207-003 2A PSU 124-209-002 2 loop base card 124-196 230V filter card 1-5 loop analogue addressable control and indicating equipment Incorporating the following units: 124-206 Processor card 124-205-002 3A PSU 124-330-001 60 zone extender 124-354 5 loop base card 124-231 Apollo Discovery loop driver card 124-195 Hochiki loop driver card 124-329 320B/380B 20 zone display The 3xxx model range Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition DX1e-40M 1 loop, 40 zone, analogue addressable control indicating equipment Incorporating the following units: 124-336 Loop base card 124-335 Display card 124-337 Printer module (DX1e-40MP only) Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols 1 loop 20 zone, analogue addressable control indicating equipment. Incorporating the following units: 124-336 Loop base card 124-335 Display card Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols 2 loop, 40 zone, analogue addressable control indicating equipment Incorporating the following units: 124-344 Loop base card 124-335 Display card 124-337 Printer module (DX2e-40MP and DX2e-40LP only) Note: The CIE is compatible with Morley protocol 2 loop, 40 zone, analogue addressable control indicating equipment Incorporating the following units: 124-344 Loop base card 124-335 Display card 124-337 Printer module (DX2e-40MP and DX2e-40LP only) Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols 4 loop, 40 zone, analogue addressable control indicating equipment 429a/07 LPCB Ref. No. 429a/02

320b

429a/05

380b

429a/06

DXIe-206

429a/07

DX2e-40L-M

429a/08

DX2e-40M

429a/08

DX4e-40L

429a/09

12 Sep 2011

61

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating the following units: 124-344 Loop base card 124-351 Two loop plug in cards 124-335 Display card 124-337 Printer module (DX4e-40LP only) Note: The CIE is compatible with Apollo, Hochiki and System sensor protocols The DX model range Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition All of the above are certified with the following options with requirements from EN 54: Part 2 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Certificate No: 154d to EN 54:Part 2 and 4: 1997 Certificated Products Horizon HRZ2-8 Horizon HRZ2-8 Horizon HRZ2-8 HRZ2-8 002-479-322 Morley-IAS Horizon, 2 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 002-492-222 Morley-IAS Horizon, 2 zone, 2w relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 002-506-222 Morley-IAS Horizon, 2 zone, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Horizon 2 Zone conventional control and indicating equipment Including the following versions: 002-479-122 Language region 1, English manual 002-479-222 Language region 2 002-479-322 Language region 3, dual relay 002-492-222 Language region 2, dual relay, English manual 002-506-222 Language region 2, English manual 002-479-342 Morley-IAS Horizon, 4 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 002-492-242 Morley-IAS Horizon, 4 zone, 2w relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 002-506-242 Morley-IAS Horizon, 4 zone, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Horizon 4 zone conventional control and indicating equipment Including the following versions: 002-479-142 Language region 1, English manual 002-479-242 Language region 2 002-479-342 Language region 3, dual relay 002-492-242 Language region 2, dual relay, English manual 002-506-242 Language region 2, English manual 002-479-382 Morley-IAS Horizon, 8 zone, dual relay, Danish, Finish, Norwegian, Swedish (Region 3) 002-492-282 Morley-IAS Horizon, 8 zone, 2w relay, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual 002-506-282 Morley-IAS Horizon, 8 zone, English, French, Spanish, Portuguese, Italian (Region 2) + UK user manual Horizon 8 zone conventional control and indicating equipment Including the following versions: 002-479-182 002-479-282 002-479-382 002-492-282 002-506-242 Language region 1, English manual Language region 2 Language region 3, dual relay Language region 2, dual relay, English manual Language region 2, English manual LPCB Ref. No. 154d/09 154d/09 154d/09 154d/09 LPCB Ref. No.

Horizon HRZ2-8 Horizon HRZ2-8 Horizon HRZ2-8 HRZ2-8

154d/10 154d/10 154d/10 154d/10

Horizon HRZ2-8 Horizon HRZ2-8 Horizon HRZ2-8 HRZ2-8

154d/11 154d/11 154d/11 154d/11

62

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products The HRZ model range Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition LPCB Ref. No.

Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition

Certificate No: 429b to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products HRZ2-8 Horizon 2 Zone conventional control and indicating equipment Including the following versions: 002-479-122 Language region 1, English manual 002-479-222 Language region 2 002-479-322 Language region 3, dual relay 002-492-222 Language region 2, dual relay, English manual 002-506-222 Language region 2, English manual Horizon 4 Zone conventional control and indicating equipment Including the following versions: 002-479-142 Language region 1, English manual 002-479-242 Language region 2 002-479-342 Language region 3, dual relay 002-492-242 Language region 2, dual relay, English manual 002-506-242 Language region 2, English manual Horizon 8 Zone conventional control and indicating equipment Including the following versions: 002-479-182 Language region 1, English manual 002-479-282 Language region 2 002-479-382 Language region 3, dual relay 002-492-282 Language region 2, dual relay, English manual 002-506-282 Language region 2, English manual LPCB Ref. No. 154d/09

HRZ4-8

154d/10

HRZ8-8

154d/11

Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition Certificate No: 429c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products DX1e-20S DX1e-20S-M DX1e-40M DX1e-40M-M 1 loop, 20 zone, analogue addressable control indicating equipment Note: The CIE is compatible with Apollo, Hochiki and System Sensor protocols 1 loop, 20 zone, analogue addressable control indicating equipment English, Spanish and Italian language versions Note: The CIE is compatible with Morley protocol 1 loop, 40 zone, analogue addressable control indicating equipment Note: The CIE is compatible with Apollo, Hochiki and System Sensor protocols 1 loop, 40 zone, analogue addressable control indicating equipment English, Spanish and Italian language versions Note: The CIE is compatible with Morley protocol LPCB Ref. No. 429c/01 429c/01 429c/01 429c/01

12 Sep 2011

63

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products LPCB Ref. No. Incorporating the following units: 124-386 Base card 124-335-001 Display card Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 loop, 40 zone, analogue addressable control indicating equipment Note: The CIE is compatible with Apollo, Hochiki and System Sensor protocols 2 loop, 40 zone, analogue addressable control indicating equipment English, Spanish and Italian language versions Note: The CIE is compatible with Morley protocol Incorporating the following units: 124-392 124-393 124-335 -001 Base card 2 loop interface board Display card

DX2e-40M DX2e-40M-M

429c/02 429c/02

DX4e-40L DX4e-40L-M

Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 4 loop, 40 zone, analogue addressable control indicating equipment Note: The CIE is compatible with Apollo, Hochiki and System Sensor protocols 4 loop, 40 zone, analogue addressable control indicating equipment English, Spanish and Italian language versions Note: The CIE is compatible with Morley protocol Incorporating the following units: 124-392 124-393 124-335 -001 Base card 2 loop interface board Display card

429c/03 429c/03

ZX1Se

Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1 loop analogue addressable control and indicating equipment 722-001-301 1 loop multi-protocol control panel, language group M100 722-001-302 1 loop multi-protocol control panel, language group M200 722-002-301 1 loop multi-protocol control panel, language group M100, Stainless Steel 722-101-301 1 loop multi-protocol control panel, language group H100 722-101-302 1 loop multi-protocol control panel, language group H200 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 124-206 124-209-005 124-370 Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module Processor Card 1 Loop Base Card 4 Line Display Card

429c/04

64

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products PS82-2-NFR 2A PSU LPCB Ref. No.

ZX2Se

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12. Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-2 loop analogue addressable control and indicating equipment 1-2 loop multi-protocol control panel, language group M100 1-2 loop multi-protocol control panel, language group M200 1-2 loop multi-protocol control panel, language group M100, Stainless Steel 720-101-301 1-2 loop multi-protocol control panel, language group H100 720-101-302 1-2 loop multi-protocol control panel, language group H200 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 124-206 124-209-004 124-370 4 PS82-2-NFR Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module Processor Card 2 Loop Base Card Line Display Card 2A PSU 720-001-301 720-001-302 720-002-301

429c/05

ZX5Se

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-5 loop analogue addressable control and indicating equipment 1-5 loop multi-protocol control panel, language group M100 1-5 loop multi-protocol control panel, language group M200 1-5 loop multi-protocol control panel, language group M100, Stainless Steel 721-101-301 1-5 loop multi-protocol control panel, language group H100 721-101-302 1-5 loop multi-protocol control panel, language group H200 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 795-077-020 795-077-060 795-051-001 124-206 124-403 124-370 4 PS196-4-NFR Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module 20 Zone LED Display Indicator Card 60 Zone LED Display Indicator Card Internal Printer Module Processor Card 5 Loop Base Card Line Display Card PSU 721-001-301 721-001-302 721-002-301

429c/06

GL4-1Se

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1 loop analogue addressable control and indicating equipment

429c/07

12 Sep 2011

65

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 722-606-301 1 loop multi-protocol control panel, language group G100 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 124-206 124-209-005 124-370 4 PS82-2-NFR Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module Processor Card 1 Loop Base Card Line Display Card 2A PSU LPCB Ref. No.

GL4-2Se

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-2 loop analogue addressable control and indicating equipment 720-606-301 1-2 loop multi-protocol control panel, language group G100 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 124-206 124-209-004 124-370 4 PS82-2-NFR Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module Processor Card 2 Loop Base Card Line Display Card 2A PSU

429c/08

GL4-5Se

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 1-5 loop analogue addressable control and indicating equipment 721-606-301 1-5 loop multi-protocol control panel, language group G100 Incorporating the following units: 795-072-100 795-068-100 795-058-105 795-066-100 795-044-001 795-004-001 795-005 795-077-020 795-077-060 795-051-001 124-206 124-403 124-370 4 PS196-4-NFR Morley-IAS Loop Driver Card System Sensor Loop Driver Card Hochiki Loop Driver Card Apollo XP95 / Discovery Loop Driver Card Nittan Loop Driver Card RS 485 Communication Module RS232 Communication Module 20 Zone LED Display Indicator Card 60 Zone LED Display Indicator Card Internal Printer Module Processor Card 5 Loop Base Card Line Display Card PSU

429c/09

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal: Type C 8.3 Fault signals from points 9.5 Disablement of addressable points

66

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Horizon HRZ2-8 10 Test condition 002-479-122 Language region 1, English manual 002-479-222 Language region 2 002-479-322 Language region 3, dual relay 002-492-222 Language region 2, English manual, dual relay 002-506-222 Language region 2, English manual 002-479-142 Language region 1, English manual 002-479-242 Language region 2 002-479-342 Language region 3, dual relay 002-492-242 Language region 2, English manual, dual relay 002-506-242 Language region 2, English manual 002-479-182 Language region 1, English manual 002-479-282 Language region 2 002-479-382 Language region 3, dual relay 002-492-282 Language region 2, English user manual, dual relay 002-506-282 Language region 2, English user manual Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition Single loop control and indicating equipment 714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland) 714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME) Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24 Two loop control and indicating equipment 714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland) 714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME) Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 010-116 PSU RS-100-24 Four loop control and indicating equipment 714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland) 714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME) Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 124-417 2 Loop PCB 010-116 PSU RS-100-24 Incorporating as optional modular units: 795-099 795-102 795-103 795-111 CIE only) 795-117 795-118 795-122 795-123 795-124 KIT DXc NETWORK CARD KIT DXc 40 ZONE LED CARD KIT DXc 80 ZONE LED CARD WITH COVER KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop KIT DXc PERFORMANCE CARD KIT DXc KEYSWITCH KIT DXc RS232 KIT DXc RS485 KIT DXc 80 ZONE LED CARD LPCB Ref. No. 429c/10

HRZ2-8e 4 Zone

429c/11

HRZ2-8e 8 Zone

429c/12

DXc1-S

429c/13

DXc2-M

429c/14

DXc4-M

429c/15

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal-Type C 7.13 Alarm counter

12 Sep 2011

67

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.3 9.5 10 Fault signals from points Disablement of each addressable point Test condition LPCB Ref. No.

Notes: 1. 2.

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality.

Multron Systems Pte Ltd


217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 Fax: +65 6743 2777 / 6395 6869 E-mail: info@multron.com Website: www.multron.com
Certificate No: 548j-(cl-6) to EN 54-2: 1997 & EN 54-4: 1997 Certificate No: 548p-(cl-3) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products MPC-101 Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829b Power supply unit F7.908.312d Zone indication and intervention board F7.820.1125 Loop board Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices LPCB Ref. No. 548j/02

MPC-102

548j/03

MPC-104

548j/04

MPC-108

548j/05

MPC-116

548j/06

IFP2

548p/01

68

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.1238 Indication board F7.820.1239 Loop board F7.820.1311 Power board F7.820.1312 ZCP board F7.820.1326 Keypad board F7.820.1237 Main board F7.820.1310 Mother board Incorporating as optional modular units: F7.820.1313 USB communication board Certified with the following options with requirements from EN 54 Part 2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.11 7.12.1 7.12.2 7.13 8.3 9.5 10 Output to fire alarm devices Output to fire routing equipment Alarm confirmation input from fire routing equipment Output type A Output type B Delays to outputs Dependencies on more than one alarm signal Type A Dependencies on more than one alarm signal Type B Alarm counter Fault signals from points Disablement of each address point Test condition LPCB Ref. No.

IFP8

548p/02

Nitin Ventures FZE


P.O. Box 262294, Jabel Ali Free Zone, Dubai, United Arab Emirates Tel: +97 148865858/859 Fax: +97 148865800 E-mail: sales@nitinventures.com Website: www.nitinventures.com
Certificate No: 018c to EN 54-2: 1997 and EN 54-4: 1997 Certificated Products Discovery 4 loop analogue addressable control and indicating equipment Incorporating as modular units: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230Vac power supply control card A1599 Printer board Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment LPCB Ref. No. 018c/01

NV 2

018c/02

12 Sep 2011

69

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power supply board C1631 Repeater interface (option) Certified with the following options with requirements from EN54-2: 1997: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface LPCB Ref. No.

NV 4

018c/03

NV 8

018c/04

NV 16

018c/05

NV 32

018c/06

NV 8R

018c/R01

NV 16R

018c/R02

NV 32R

018c/R03

70

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Notifier Fire Systems by Honeywell


Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 154d to EN 54-2: 1997, EN 54-4: 1997 Certificated Products ID2000 2-8 loop analogue addressable control and indicating equipment 020-628 Language Group 0 basic equipment kit 020-628-001 Language Group 1 basic equipment kit Fixed 2 loop analogue addressable control and indicating equipment 002-459 002-459-001 002-472 Language Group 0 Language Group 1 Languarge Group 0, red cover LPCB Ref. No. 154d/01

ID2002

154d/01

Incorporating as modular units: 020-469-009 Extension Chassis with 17-80 Zone LED Display 020-708-009 Extension Chassis with Printer 020-644-009 Printer Assembly 020-588 LIB, Loop Interface Board 020-478 RS232 Communications Kit 020-479 RS485 Communications Kit 020-484 PSU2.5A Power Supply 020-648 PSU3A Power Supply 020-579 PSU7A Power Supply (Requires DTP / Booster Interface) 020-543 Interface 020-541-009 78Ah Battery and PSU7A Enclosure 020-472-009 Standard Back Box Kit 020-473-009 Extended Back Box Kit 020-474-009 Extended Deep Back Box Kit 020-475-009 Double Extended Back Box Kit 020-476-009 Double Extended Deep Back Box Kit 020-508-009 Standard Back Box Extension Kit 020-509-009 Deep Back box Extension Kit 020-480-009 Main Cover Kit 020-481-009 Extension Cover Kit 020-513-009 High Security Main Cover 020-514-009 High Security Extension Cover Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition Fixed 2 loop analogue addressable control and indicating equipment 002-474 Language Group 0 002-474-001 Language Group 1 002-473 Language Group 0, red cover Incorporating as modular units: 020-559-001 020-559-002 020-612 020-708-009 020-644-009 020-588 020-549 Extension Chassis with 1-64 Zone LED Display Extension Chassis with 65-128 Zone LED Display Extension Chassis with 1-256 Zone LED Display Extension Chassis with Printer Printer Assembly LIB Loop Interface Board ELIB, Enhanced Loop Interface Board DTP Dual Transmission Path / Booster

ID3002

154d/01

12 Sep 2011

71

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 020-478 RS232 Communications Kit 020-479 RS485 Communications Kit 020-484 PSU2.5A Power Supply 020-648 PSU3A Power Supply 020-579 PSU7A Power Supply (Requires DTP / Booster Interface) 020-543 DTP Dual Transmission Path / Booster Interface 020-541-009 78Ah Battery and PSU7A Enclosure 020-472-009 Standard Back Box Kit 020-473-009 Extended Back Box Kit 020-474-009 Extended Deep Back Box Kit 020-475-009 Double Extended Back Box Kit 020-476-009 Double Extended Deep Back Box Kit 020-508-009 Standard Back Box Extension Kit 020-509-009 Deep Backbox Extension Kit 020-480-009 Main Cover Kit 020-481-009 Extension Cover Kit 020-513-009 High Security Main Cover 020-514-009 High Security Extension Cover 020-621-009 256 Zone LED Display Cover 020-647 NGM ID2net Network Gateway Module 020-643 Fibre Optic Interface Module 2-8 loop analogue addressable control and indicating equipment 002-538 Language Group 0 basic equipment kit 020-538-001 Language Group 1 basic equipment kit ID300x panel and associated units are certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to Fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-455 Language Group 0, 1.5A PSU, 12Ah batteries 002-455-001 Language Group 1, 1.5A PSU, 12Ah batteries 020-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-462 Language Group 0, 3A PSU, 12Ah Batteries, Printer Option 002-462-001 Language Group 1, 3A PSU, 12Ah Batteries, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-460 Language Group 0, 3A PSU, 42Ah Batteries, Printer Option 002-460-001 Language Group 1, 3A PSU, 42Ah Batteries, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-456 Language Group 0, 1.5A PSU, 12Ah batteries, VIEW 002-456-001 Language Group 1, 1.5A PSU, 12Ah batteries, VIEW 020-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-463 Language Group 0, 3A PSU, 42Ah Batteries, VIEW, Printer Option 002-463-001 Language Group 1, 3A PSU, 12Ah Batteries, VIEW, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit Single loop analogue addressable control and indicating equipment Incorporating the following units: 002-461 Language Group 0, 3A PSU, 42Ah Batteries, VIEW, Printer Option LPCB Ref. No.

ID3000

154d/02

ID50

154d/03

ID51

154d/04

ID52

154d/05

ID60

154d/06

ID61

154d/07

ID62

154d/08

72

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 002-461-001 Language Group 1, 3A PSU, 42Ah Batteries, VIW, Printer Option 020-553 RS485 Communication Kit 020-644-009 PRN-ID Printer Kit The ID5x/6x models are certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm Counter 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition 2 Zone conventional control and indicating equipment Including the following versions: 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-490-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manual 4 Zone conventional control and indicating equipment Including the following versions: 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-490-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay, English manual 002-490-149 Language region 1, black & grey, dual relay, English manual 002-490-249 Language region 2, black & grey, dual relay, English manual 002-490-242 Language region 2, light grey, English manual 8 Zone conventional control and indicating equipment Including the following versions: 002-477-182 Language region 1, light grey 002-477-189 Language region 1, black & grey 002-477-282 Language region 2, light grey 002-477-289 Language region 2, black & grey 002-477-382 Language region 3, light grey, dual relay 002-477-389 Language region 3, black & grey, dual relay, English manual 002-490-189 Language region 1, black & grey, dual relay, English manual 002-490-289 Language region 2, black & grey, dual relay, English manual 002-490-282 Language region 2, light grey, English manual LPCB Ref. No.

NFS2-8

154d/09

NFS2-8

154d/10

NFS2-8

154d/11

The NFS2-8 (2-8 zones) panels are certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Coincidence detection 10 Test condition Incorporating the following modular units, is approved for use with the ID3000 control and indicating equipment: 020-647 NGM, ID2net Network Gateway Module 020-643 Fibre Optic Interface Module 020-648 PSU3A Power Supply Module

002-467 NGU, ID2net Network Gateway Unit

154d/N02

Certificate No: 154f to ISO 7240: Part 2 & 4: 2003 Certificated Products NFS2-8 2 zone conventional control and indicating equipment LPCB Ref. No. 154f/01

12 Sep 2011

73

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Including the following versions: 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-477-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manual 4 zone conventional control and indicating equipment Including the following versions: 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-477-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay, English manual 002-490-149 Language region 1, black & grey, dual relay, English manual 002-490-249 Language region 2, black & grey, dual relay, English manual 002-490-242 Language region 2, light grey, English manual 8 zone conventional control and indicating equipment Including the following versions: 002-477-182 Language region 1, light grey 002-477-189 Language region 1, black & grey 002-477-282 Language region 2, light grey 002-477-289 Language region 2, black & grey 002-477-382 Language region 3, light grey, dual relay 002-477-389 Language region 3, black & grey, dual relay, English manual 002-490-189 Language region 1, black & grey, dual relay, English manual 002-490-289 Language region 2, black & grey, dual relay, English manual 002-490-282 Language region 2, light grey, English manual The NFS2-8 (2 -8 zones) panels are certified with the following options from ISO 7240 Part 2: 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.11 Delays to outputs 7.12 Dependency detection 11 Test condition LPCB Ref. No.

NFS2-8

154f/02

NFS2-8

154f/03

Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ID3000 Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-538 Basic Equipment Kit ID3000, Group 0 020-538-001 ID3000 Basic Equipment Kit, Group 1 020-538-003 ID3000 Basic Equipment Kit, Group 3 020-538-004 ID3000 Basic Equipment Kit, Group 4 020-538-005 ID3000 Basic Equipment Kit, Group 5 Fixed build 2 loop analogue addressable control and indicating equipment. 002-473 ID3002, 2 Loop, PSU3A, Group 0, Red 002-474 ID3002, 2 Loop, PSU3A, Group 0 002-474-001 ID3002, 2 Loop, PSU3A, Group 1 002-474-003 ID3002, 2 Loop, PSU3A, Group 3 002-474-004 ID3002, 2 Loop, PSU3A, Group 4 002-474-005 ID3002, 2 Loop, PSU3A, Group 5 Fixed build 4 loop analogue addressable control and indicating equipment. 020-727 ID3004, 4 Loop, PSU7A, Group 0, LIB 020-728 ID3004, 4 Loop, PSU7A, Group 0, ELIB LPCB Ref. No. 154g/01

ID3002

154g/01

ID3004

154g/01

74

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 020-729 ID3004, 4 Loop, PSU7A, Group 0, LIB, printer 020-730 ID3004, 4 Loop, PSU7A, Group 0, LIB, 64 zone LED Fixed build 6 loop analogue addressable control and indicating equipment. 020-731 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB 020-732 ID3006, 6 Loop, PSU7A, Group 0, 2xELIB 020-733 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, printer 020-734 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, 64 zone LED Fixed build 8 loop analogue addressable control and indicating equipment. 020-735 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure 020-736 ID3008, 8 Loop, PSU7A, Group 0, 3xELIB, 78Ah Battery Enclosure 020-737 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure, Printer 020-738 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery enclosure, printer, 64 Zone LED ID3000 series Incorporating the following as modular units: Enclosures: 020-472-009 Backbox Kit Standard, Black / Grey 020-473-009 Backbox Kit Extended, Black / Grey 020-474-009 Backbox Kit Extended Deep, Black / Grey 020-475-009 Backbox Kit Double Extended, Black / Grey 020-476-009 Backbox Kit Double Extended Deep, Black / Grey 020-480-009 Cover Kit Main Moulded, Black / Grey 020-481-009 Cover Kit Extended Moulded, Black / Grey 020-508-009 Backbox Extension Standard Assembly Black / Grey 020-509-009 Backbox Extension Deep Assembly Black / Grey 020-513-009 High Security Cover Kit Main, Black / Grey 020-514-009 High Security Cover Kit Extension 020-576 Main Cover, Stainless Steel 020-577 Extension Cover Stainless Steel 020-621-256 Zone Extension Cover, Stainless / Steel 020-621-009 256 Zone Extension Cover, Black / Grey 020-541-009 PSU7A / 78Ah Battery Enclosure Modules: 020-559-001 Module 020-559-002 Module 020-612 020-708-009 020-644-009 020-588 020-549 (ELIB) 020-478 020-479 020-648 020-579 020-548 020-543 020-773 020-877 020-643 020-647 Note 1: RS232 Interface RS485 Interface PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface) PSU7A Status Indication Dual Transmission Path / Booster, PSU Interface Routing Termination Unit (DEOL) Extinguishing Interface Module M221-SI IDnet Fibre Optic Interface Kit IDnet Network Gateway Module, (NGM) for use in ID3000 Panel Double Extended Chassis Kit 256 Zone Extension Chassis with Printer Printer Assembly Notifier Dual Loop Interface Board, (LIB) Notifier Dual Enhanced Loop Interface Board, Zone Extension Chassis Kit 65-128 Zone C/W Display LPCB Ref. No. 154g/01

ID3006

ID3008

154g/01

Zone Extension Chassis Kit 1-64 Zone C/W Display

Products are available in language variants as follows: Group 0: English and Icelandic, with English manuals Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English and Polish Group 5: English and Cyrillic Fixed build products incorporate a corresponding Basic Equipment Kit. 154g/02

Note 2: ID50

Single loop analogue addressable control and indicating equipment 002-455 ID50 Panel Group 0 002-455-001 ID50 Panel Group 1 002-455-003 ID50 Panel Group 3 002-455-004 ID50 Panel Group 4 May also incorporate the following optional modular unit:

12 Sep 2011

75

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products ID60 002-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment 002-456 ID60 Panel Group 0 002-456-001 ID60 Panel Group 1 002-456-003 ID60 Panel Group 3 002-456-004 ID60 Panel Group 4 May also incorporate the following optional modular unit: 002-553 RS485 Communication Kit Single loop analogue addressable control and indicating equipment 002-463 ID61 Panel Group 0 002-463-001 ID61 Panel Group 1 002-463-004 ID61 Panel Group 4 002-485-001 ID61 Panel Group 1 (Red) Incorporating the following modular unit: 020-648 PSU3A Kit May also incorporate the following optional modular units: 020-479 RS485 Communication Kit 020-644-009 Printer Kit Single loop analogue addressable control and indicating equipment 002-461 ID62 Panel Group 0 002-461-001 ID62 Panel Group 1 002-461-004 ID62 Panel Group 4 Incorporating the following modular unit: 020-648 PSU3A Kit May also incorporate the following optional modular units: 020-479 RS485 Communication Kit 020-644-009 Printer Kit Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment: Type A 7.10.3 Outputs to fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to Outputs 7.12.2 Dependencies on more than one alarm signal: Type B 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition LPCB Ref. No. 154g/03

ID61

154g/04

ID62

154g/05

NFS2-8 2 Zone

NFS2-8 4 Zone

NFS2-8 8 Zone

Note: Products are available in various language groups as follows: Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, (shipped with English manuals) Group 1: English, Icelandic, French, Italian, Portuguese and Spanish Group 2: English, Dutch, German, French and Italian Group 3: English, Swedish, Danish, Norwegian and Finnish Group 4: English and Polish 002-477-122 Language region 1, light grey 002-477-129 Language region 1, black & grey 002-477-222 Language region 2, light grey 002-477-229 Language region 2, black & grey 002-477-322 Language region 3, light grey, dual relay 002-477-329 Language region 3, black & grey, dual relay, English manual 002-490-129 Language region 1, black & grey, dual relay, English manual 002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manua 002-477-142 Language region 1, light grey 002-477-149 Language region 1, black & grey 002-477-242 Language region 2, light grey 002-477-249 Language region 2, black & grey 002-477-342 Language region 3, light grey, dual relay 002-477-349 Language region 3, black & grey, dual relay 002-490-149 Language region 1, black & grey, dual relay, English manual 002-490-249 Language region 2, black & grey, dual relay, English manual 002-490-242 Language region 2, light grey, English manual 002-477-182 Language region 1, light grey

154g/06

154g/07

154g/08

76

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 002-477-189 002-477-282 002-477-289 002-477-382 002-477-389 002-490-189 002-490-289 002-490-282 Language region 1, black & grey Language region 2, light grey Language region 2, black & grey Language region 3, light grey, dual relay Language region 3, black & grey, dual relay Language region 1, black & grey, dual relay, English manual Language region 2, black & grey, dual relay, English manual Language region 2, light grey, English manual LPCB Ref. No.

Incorporating the following units: 020-747 8-Way relay kit 020-772 4-way monitored sounder kit Certified with the following options from EN 54 Part 2: Output to fire alarm devices Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment: Type A 7.10.3 Output to automatic fire protection equipment: Type C 7.10.4 Fault monitoring of fire protection equipment 7.11.1 Delays to outputs 7.11.2 Manual or automatic switching of delays to outputs 7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment 10 Test condition Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment. 020-628 Basic equipment kit ID2000 Group 0, 020-628-001Basic equipment kit ID2000 Group 1, UK ES PT IT 020-628-002Basic equipment kit ID2000 Group 2, UK NL FR Fixed build 2 loop analogue addressable control and indicating equipment. 002-459 ID2002, 2 loop control and indicating equipment, Group 1 Incorporating the following as optional modular units: Enclosures: 020-472-009 020-473-009 020-474-009 020-475-009 020-476-009 020-480-009 020-481-009 020-508-009 020-509-009 020-576 020-577 020-541-009 Modules: 020-649-009 020-708-009 020-644-009 020-588 020-478 020-479 020-648 Backbox Kit Standard, Black / Grey Backbox Kit Extended, Black / Grey Backbox Kit Extended Deep, Black / Grey Backbox Kit Double Extended, Black / Grey Backbox Kit Double Extended Deep, Black / Grey Cover Kit Main Moulded, Black / Grey Cover Kit Extended Moulded, Black / Grey Backbox Extension Standard Assembly Black / Grey Backbox Extension Deep Assembly Black / Grey Main Cover, Stainless Steel Extension Cover Stainless Steel PSU7A / 78Ah Battery Enclosure 64 Zone Extension Chassis Kit 64 Zone C/W Display Module Extension Chassis with Printer Printer Assembly Notifier Dual Loop Interface Board, (LIB) RS232 Interface RS485 Interface PSU3A PSU7A, (Requires Dual Transmission Path / Booster, PSU 7.8 7.9.1

ID2000

154g/09

ID2002

154g/09

Interface) 020-543 Dual Transmission Path / Booster, PSU Interface 020-548 PSU7A Status Indication Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 9.5 Disablements of addressable points 10 Test condition

12 Sep 2011

77

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Note 2: manuals) 002-467 Group 1: English, Spanish, Portuguese and Italian Group 2: English, Dutch, and French IDnet Network Gateway Unit, (NGU) Notifier Protocol Incorporating the following as modular units: 020-643 IDnet Fibre Optic Interface Kit 020-647 IDnet Network Gateway Module, (NGM) for use in ID3000 Panels 020-648 PSU3A Certified with the following options with requirements: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Output to fire protection equipment type A 7.10.3 Output to fire protection equipment type C 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.2 Dependency on more than one alarm signal type B 7.12.3 Dependency on more than one alarm signal type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablements of addressable points 10 Test condition 154g/NO1 Products are available in language variants as follows: Group 0: English, Spanish, Portuguese and Italian (shipped with English LPCB Ref. No.

Olympia Electronics S.A.


Kolindros Pierias, 60061, Australia Tel: (+30) 2353051200 Fax: (+30 )2353051486 E-mail: info@olympia-electronics.gr Website: www.olympia-electronics.gr
Certificate No: 1010a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2 006 Certificated Products BSR-2104 Two loop analogue addressable control and indicating equipment. Incorporating the following units: 1702091 Main board 0905073 Main processor board 0506073 Input / Output Unit 1603073 LED PCB board 2307103 Loop 1 incorporating power control board DPP100-24 Lambda PSU block Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to fire protection equipment (Type A) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.13 Alarm counter 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Four loop analogue addressable control and indicating equipment. Incorporating the following units: 1702091 Main board 0905073 Main processor board 0506073 Input / Output Unit 1603073 LED PCB board LPCB Ref. No. 1010a/01

BSR-2114

1010a/02

78

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2307103 2607103 DPP100-24 Loop 1 incorporating power control board Loop 2 board Lambda PSU block LPCB Ref. No.

Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to fire protection equipment (Type A) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.13 Alarm counter 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

Pelco Finland Oy
Kalkkipellontie 6, PO Box 415, Fl-02601 Espoo, Finland Tel: +358 10 446 511 Fax: +358 10 446 5103 Website: www.pelco.com/nordic Manufactured at: Pelco Finland Oy, Manttaalitie 5-7, 01530 Vantaa, Finland

Certificate No: 883b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2 : 2006 Certificated Products FX 8 Loop Analogue addressable CIE Basic unit incorporates the following modules: FX-MC FX-UI FX-PSB or FX-PSA Master controller User interface 4.5 A Power Supply 2.2 A Power Supply LPCB Ref. No. 883b/01

Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB FX-ALCA FX-LC FX-SLC FX-CLC FX-IOC FX-OCA FX-SAA Two loop addressable controller Apollo protocol card One loop addressable controller Apollo protocol card Two loop addressable controller System Sensor protocol card Two loop addressable controller System Sensor advanced protocol card Sixteen loop conventional Controller I/O controller board 16 clean output module Serial communications adapter for communication with external Systems (BSM or Alarm Management Systems). FX-SAB Serial communications adapter for communication in a networked FX system and with external systems (BSM or Alarm Management Systems). FX-SAC Serial communication module FX-LB80 80 Zone LED indication card FX-LB32 32 Zone LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.10.3 7.11 Outputs to fire alarm devices Output to fire alarm routing equipment Output to Fire Protection Equipment (Output Type C) Delays to outputs

12 Sep 2011

79

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.12.2 7.13 8.3 8.4 8.9 9.5 10 Dependencies on more than one alarm signal (Type B) Alarm counter Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

FXL

Notes: 1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 8 Loop Analogue addressable CIE Basic unit incorporates the following modules: FX-MC FX-UI FX-PSB or FX-PSA Master controller User interface 4.5 A Power Supply 2.2 A Power Supply

883b/02

Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB FX-ALCA FX-LC FX-SLC card FX-CLC FX-IOC FX-OCA FX-SAA FX-SAB FX-SAC FX-LB80 FX-LB32 FX-BAT FXM-BAT Two loop addressable controller - Apollo protocol card One loop addressable controller - Apollo protocol card Two loop addressable controller - System Sensor protocol card Two loop addressable controller System Sensor advanced protocol Sixteen loop conventional Controller I/O controller board 16 clean output module Serial communications adapter for communication with external systems (BSM or Alarm Management Systems). Serial communications adapter for communication in a networked FX system and with external systems (BSM or Alarm Management Systems). Serial communication module 80 Zone LED indication card 32 Zone LED indication card Separate battery box (4x17Ah, 12V) Separate battery box (4x12Ah, 12V)

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.10.3 7.11 7.12.2 7.13 8.3 8.4 8.9 9.5 10 Notes: 1) 2) Outputs to fire alarm devices Output to fire alarm routing equipment Output to Fire Protection Equipment (Output Type C) Delays to outputs Dependencies on more than one alarm signal (Type B) Alarm counter Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Scope of approval does not include the operation of the network functionality. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 883b/03

FXM

4 Loop Analogue addressable CIE Basic unit incorporates the following modules:

80

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products FX-MC FX-UI FX-PSB or FX-PSA Master Controller User Interface 4.5 A Power Supply 2.2 A Power Supply LPCB Ref. No.

Optional Modules -The following modules are optional additions to the basic unit: FX-ALCB protocol card FX-ALCA protocol card FX-LC Two loop addressable controller System sensor protocol card FX-SLC Two loop addressable controller System Sensor advanced protocol card FX-CLC Sixteen loop conventional Controller FX-IOC I/O controller board FX-OCA 16 clean output module FX-SAA Serial communications adapter for communication with external systems (BSM or Alarm Management Systems) FX-SAB Serial communications adapter for communication in a networked FX system and with external systems (BSM or Alarm Management Systems). FX-SAC Serial communication module FX-LB80 80 Zone LED indication card FX-LB32 32 Zone LED indication card FX-BAT Separate battery box (4x17Ah, 12V) FXM-BAT Separate battery box (4x12Ah, 12V) Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.10.3 7.11 7.12.2 7.13 8.3 8.4 8.9 9.5 10 Notes: 1) 2) Outputs to fire alarm devices Output to fire alarm routing equipment Output to Fire Protection Equipment (Output Type C) Delays to outputs Dependencies on more than one alarm signal (Type B) Alarm counter Fault signals from points Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition One loop addressable controller Apollo Two loop addressable controller Apollo

Scope of approval does not include the operation of the network functionality.

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. FXS Analogue addressable Repeater Panel Incorporating the following modules: FX-MC FX-UI Master Controller User Interface 883b/R01

Optional Modules -The following modules are optional additions to the basic unit: FX-IOC I/O Controller

12 Sep 2011

81

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT

Protec Fire Detection plc


Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 Fax: +44 (0)1282 717273 E-mail: sales@protec.co.uk Website: www.protec.co.uk
Certificate No: 201k to EN 54-2: 1997 and EN 54-4: 1997 Certificate No: 201ad to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006 Certificated Products 6400/DCN Display and Control node Incorporating the following units: WEFA 312E WEFA 168E WEFA 233E Display control unit Local display unit PF Terminal unit LPCB Ref. No. 201ad/01

Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm device(s) 7.9.1 Output to fire alarm routing equipment 7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition Notes: 1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node 6400/PSU 8A Power supply with charger Scope of approval does not include the operation of the network functionality. 201ad/02

2. 6400/2LPN

2 Loop processing node Incorporating the following units: WEFA 169E SSU WEFA 315B Dual loop driver WEFA 160E Local IO WEFA 230C Terminal board WEFA 232D 6400 Loop terminal board WEFA 237A LPN display board WEFA 288C 6400 OPTO isolated 485 board WEFA 315B 6400 Loop Transmission board Notes: 1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 542 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2. Scope of approval does not include the operation of the network functionality.

6400/4LPN

4 Loop processing node Incorporating the following units: WEFA 169E SSU

201ad/03

82

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products WEFA 315B 2 x Dual loop driver WEFA 160E Local IO WEFA 230C 5400 Terminal board WEFA 232D 6400 Loop terminal board WEFA 237A LPN display board WEFA 288C 6400 OPTO 485 board WEFA 315B 6400 Loop Transmission board Notes: 1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/PSU 8A Power supply with charger 2. Scope of approval does not include the operation of the network functionality. 6400/DCN/2LPN Display and control node plus 2 Loop processing node Incorporating the following units: WEFA 312E WEFA 168E WEFA 169E WEFA 315B WEFA 160E WEFA 230C WEFA 232D WEFA 288C WEFA 312E WEFA 315B Display control unit 5400 LED display unit SSU Dual loop driver Local IO 5400 Terminal board 6400 Loop terminal board 6400 OPTO isolated 485 board X400 SMT Display and control unit 6400 Loop Transmission board 201ad/04 LPCB Ref. No.

Certified with the following options with requirements from EN 54: Part 2: 7.8 7.9.1 7.11 7.12.3 7.13 8.3 8.9 9.5 10 Notes: 1. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Dependencies on more than one alarm signal Type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of each address point Test condition This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/PSU 8A Power supply with charger Scope of approval does not include the operation of the network functionality. 201ad/05

2. 6400/DCN/4LPN

Display and control node plus 4 Loop processing node Incorporating the following units: WEFA 312E Display control unit WEFA 168E 5400 Local display unit WEFA 169E SSU WEFA 315B 2 x Dual loop driver WEFA 160E Local IO WEFA 230C 5400 Terminal board WEFA 232C 6400 Loop terminal board WEFA 288C 6400 OPTO isolated 485 board WEFA 312E X400 SMT Display and control unit WEFA 315B 6400 Loop Transmission board Certified with the following options with requirements from EN 54: Part 2: 7.8 7.9.1 Output to fire alarm device(s) Output to fire alarm routing equipment

12 Sep 2011

83

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.11 7.12.3 7.13 8.3 8.9 9.5 10 Notes: 1. Delays to outputs Dependencies on more than one alarm signal Type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of each address point Test condition This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/PSU 8A Power supply with charger Scope of approval does not include the operation of the network functionality. 201ad/06 LPCB Ref. No.

2. 6400/PSU

8A Power supply with charger Incorporating the following units: 9000/BC8/40 8A Power supply with charger Notes: 1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units: 6400/DCN Display and Control node 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node 2. Scope of approval does not include the operation of the network functionality. 3. Certified to EN 54-4 only.

6301

6302

6304

Analogue addressable 1 Loop control and indicating equipment Incorporating the following units: 41-860-52 Main Board 41-850-50 Terminal Board 40-877-65 CP250 Printer Board 31-100-22 Backbox 31-243-36 Inner Plate 62-407-57 Door 04-701-38 Printer Mechanism 40-465-43 Series 9000 Power Supply Unit 31-275-44 Optional external 24 AH battery box 40-879-67 Network Card (Note: Scope of approval does not include the operation of the network card) Analogue addressable 2 Loop control and indicating equipment Incorporating the following units: 41-860-52 Main Board 41-850-50 Terminal Board 40-879-67 CP250 Printer Board 31-100-22 Backbox 31-243-36 Inner Plate 62-407-57 Door 04-701-38 Printer Mechanism 40-465-43 Series 9000 Power Supply Unit 31-275-44 Optional external 24 AH battery box 40-879-67 Network Card (Note: Scope of approval does not include the operation of the network card) Analogue addressable 4 Loop control and indicating equipment Incorporating the following units: 41-860-52 Main Board 41-850-50 Terminal Board 40-879-67 CP250 Printer Board 31-100-22 Backbox 31-243-36 Inner Plate 62-407-57 Door 04-701-38 Printer Mechanism 40-465-43 Series 9000 Power Supply Unit

201k/01

201k/02

201k/03

84

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 41-913-56 SMT Dual 6000 Loop Card 31-275-44 Optional external 24 AH battery box 40-879-67 Network Card (Note: Scope of approval does not include the operation of the network card) LPCB Ref. No.

SHIELD FIRE, SAFETY & SECURITY LTD


28th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United Kingdom Tel: +44 161 257 2541 Fax: +44 161 225 8817 E-mail: dorota@xportsales.com Website: www.xportsales.com
Certificate No: 548j to EN 54-2:1997 & EN54-4:1997 Certificate No: 548p-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products P-A300 Intelligent 1 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power supply unit F7.908.312 Zone indication board CGM12864 Alphanumeric display F2.910.093 Mains filter R150 Transformer F2.828.630a Printer board (option) Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10 Output to automatic Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 8.3 Fault signals from points 9.5 Disablement of addressable points Single zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Two zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 10 Test condition Four zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Eight zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Sixteen zone conventional control and indicating equipment Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.11 Delays to outputs 10 Test condition Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.826 Main board LPCB Ref. No. 548j/01

P-C201

548j/02

P-C202

548j/03

P-C204

548j/04

P-C208

548j/05

P-C216

548j/06

P-A2M

548p/01

12 Sep 2011

85

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products F7.820.827 F7.820.828 F7.820.829b F7.908.312d F7.820.1125 Switch board Loop interface board Power supply unit Zone indication and intervention board Loop board LPCB Ref. No.

Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit Certified with the following options with requirements from EN 54 part 2: 7.8 Output to Fire Alarm Devices 7.10.1 Output to automatic Fire Protection Equipment Type A 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment Incorporating the following units: F7.820.1238 Indication board F7.820.1239 Loop board F7.820.1311 Power board F7.820.1312 ZCP board F7.820.1326 Keypad board F7.820.1237 Main board F7.820.1310 Mother board Incorporating as optional modular units: F7.820.1313 USB communication board Certified with the following options with requirements from EN 54 Part 2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.11 7.12.1 7.12.2 7.13 8.3 9.5 10 Output to fire alarm devices Output to fire routing equipment Alarm confirmation input from fire routing equipment Output type A Output type B Delays to outputs Dependencies on more than one alarm signal Type A Dependencies on more than one alarm signal Type B Alarm counter Fault signals from points Disablement of each address point Test condition

P-A8M

548p/02

Siemens Switzerland Limited, Building Technologies Division


International Headquarters, Fire Safety & Security Products, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 Fax: +41 (0) 41 724 35 22 Manufacturing at: Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland Tel: +41 1 922 6111 Fax: +41 1 922 6450

UK Sales: Fire Safety and Security Limited Tel: +44 (0)1734 783703 Fax: +44 (0)1734 775750

Certificate No: 126h-(cl1) to EN 54-2: 1997 and EN 54-4: 1997 Certificate No: 126aw-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-5: 1997 + A1: 2002 + A2: 2006 Certificate No: 126aw-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

86

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products FC2020 Control and indicating equipment Incorporating as modular units: FCM2001-A2 FP2001-A1 FCI2002-A1 FHA2002-A1 Operating unit 70W Power supply Periphery board (2-Loop) Rear housing LPCB Ref. No. 126aw/01

and as optional modular units: FCM2002-A2 FCM2004-A1 FCM2005-A2 FCM2006-A2 FTO2001-A1 FCI2003-A1 FTO2002-A1 FN2001-A1 FCA2001-A1 FCA2002-A1 FCI2001-D1 FCM2003-C2 FCM2003-N2 FTO2004-C1 FTO2007-N1 SV 24V-150W REDUX Operating unit PMI- & mainboard Operating add-on module Operating add-on module (2 LED indicator) Event printer Loop extension (FDnet) 24 LED indicator (internal) Networking module (See Note 1) Isolated RS232 module Isolated RS485 module Fire brigade periphery module Operating unit (incl. FBA-Term.CH) Operating unit (incl. EVAC-Term.NL) PCB compl. FBA-Terminal (CH) PCB compl. EVAC- module (NL) 150W Power supply Redundancy module

Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.1 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 11 Note: 1) 2) FC2030 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/02 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type A (only for MS9i & collective line technology) Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition Standardised input/output interface

Control and indicating equipment Incorporating as modular units: FCM2001-A2 SV24V-150W FCI2002-A1 FHA2003-A1 FCA2007-A1 Operating unit 150W Power supply Periphery board (2-Loop) Rear housing Card cage (2 slot)

and as optional modular units: FCM2002-A2 FCM2004-A1 Operating unit PMI- & mainboard

12 Sep 2011

87

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-D1 Operating add-on (DA ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FTO2003-D1 Emergency alarm indicator FCA2006-A1 Connection mod. (Card Cage) FCI2008-A1 I/O card (programmable) FCL2001-A1 Line card (FDnet) FCL2002-A1 Line card (collective) FCL2003-A1 Line card (MS9i) REDUX Redundancy module LPCB Ref. No.

Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.1 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Note: 1) 2) FC2040 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/03 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type A (only for MS9i & collective line technology) Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition

Control and indicating equipment Incorporating as modular units; FCM2001-A2 FCM2007-A2 SV24V-150W FCI2004-A1 FHA2003-A1 Operating unit Operating add-on (4 LED ind.) 150W Power supply Periphery board (4-Loop) Rear housing

and as optional modular units: FCM2002-A2 FCM2004-A1 FCM2005-A2 FCM2006-A2 FTO2001-A1 FCI2003-A1 FTO2002-A1 FN2001-A1 FCA2001-A1 FCA2002-A1 FCI2001-D1 FCM2003-C2 FCM2003-N2 FTO2004-C1 FTO2007-N1 Operating unit PMI- & mainboard Operating add-on module Operating add-on module (2 LED indicator) Event printer Loop extension (FDnet) 24 LED indicator (internal) Networking module (See Note 1) Isolated RS232 module Isolated RS485 module Fire brigade periphery module Operating unit (incl. FBA-Term.CH) Operating unit (incl. EVAC-Term.NL) PCB compl. FBA-Terminal (CH) PCB compl. EVAC- module (NL)

88

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products REDUX Redundancy module LPCB Ref. No.

Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Note: 1) 2) FC2060 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/04 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition

Control and indicating equipment Incorporating as modular units: FCM2001-A2 SV24V-150W FCI2004-A1 FHA2003-A1 FCA2008-A1 Operating unit 150W Power supply Periphery board (4-Loop) Rear housing Card cage (5 slot)

and as optional modular units: FCM2002-A2 Operating unit FCM2004-A1 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-D1 Operating add-on (DA ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FTO2003-D1 Emergency alarm indicator FCA2006-A1 Connection mod. (Card Cage) FCI2008-A1 I/O card (programmable) FCL2001-A1 Line card (FDnet) FCL2002-A1 Line card (collective) FCL2003-A1 Line card (MS9i) REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.1 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type A (only for MS9i & collective line technology)

12 Sep 2011

89

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Note: 1) 2) FC721 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/05 Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

Control and indicating equipment Incorporating as modular units: FCM7201-Z3 FP2001-A1 FCI2010-A1 FHA2002-A1 Operating unit 70W Power supply Periphery board (1-Loop) Rear housing

and as optional modular units: FCM7202-Y3 FCM7203-H3 FCM2004-A1 FTO2001-A1 FTO2002-A1 FN2001-A1 FCA2001-A1 FCA2002-A1 Operating unit (+ LED Ind.) Operating unit (+ EVAC-Term.) PMI- & mainboard Event printer 24 LED indicator (internal) Networking module (See Note 1) Isolated RS232 module Isolated RS485 module

Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.1 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Note: 1) 2) FC722 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/06 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type A (only for MS9i & collective line technology) Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition

Control and indicating equipment Incorporating as modular units: FCM7201-Z3 SV24V/150W FCI2002-A1 FHA2003-A1 Operating unit 150W Power supply Periphery board (2-Loop) Rear housing

and as optional modular units:

90

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products FP2001-A1 70W Power supply FHA2001-A1 Rear housing FCM7202-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2004-A1 PMI- & mainboard FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Note: 1) 2) FC724 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/07 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

Control and indicating equipment Incorporating as modular units: FCM7201-Z3 SV24V/150W FCI2004-A1 FHA2003-A1 Operating unit 150W Power supply Periphery board (4-Loop) Rear housing

and as optional modular units: FCM7202-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2004-A1 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module REDUX Redundancy module Certified with the following Options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10.1 7.10.2 7.10.3 Output to fire alarm devices Output to fire alarm routing equipment Alarm Confirmation from fire alarm routing equipment Output to automatic fire protection equipment Type A Output to automatic fire protection equipment Type B Output to automatic fire protection equipment Type C

12 Sep 2011

91

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.10.4 7.11 7.12.2 7.12.3 7.13 8.3 8.9 9.5 10 Note: 1) 2) FT2040 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/R0 1 Fault monitoring of automatic fire protection equipment Delays to outputs Coincidence detection type B (only for FDnet & MS9i line technology) Coincidence detection type C Alarm counter Fault signals from points Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

Fire detection terminal for use with FC2020, FC2030, FC2040 & FC2060 control and indicating equipment Incorporating as modular units: FCM2002-A2 FTI2001-A1 FHA2001-A1 Operating unit Fire terminal board Rear housing

and as optional modular units: FCM2001-A2 Operating unit FCM2004-A1 PMI- & mainboard FTO2001-A1 Event printer FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) FP2001-A1 70W Power supply H28G200 Housing base REDUX Redundancy module Note: 1) 2) FT724 Scope of approval does not include the operation of the network functionality. This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126aw/R0 2

Fire detection terminal for use with FC721, FC722 & FC724 control and indicating equipment Incorporating as modular units: FCM7201-Z3 FTI2001-A1 FHA2001-A1 Operating unit Fire terminal board Rear housing

and as optional modular units: FCM7202-Y3 FCM7203-H3 FCM2004-A1 FTO2001-A1 FTO2002-A1 FN2001-A1 FCA2001-A1 FCA2002-A1 FP2001-A1 H28G200 REDUX Note: 1) Scope of approval does not include the operation of the network functionality. Operating unit (+ LED Ind.) Operating unit (+ EVAC-Term.) PMI- & mainboard Event printer 24 LED indicator (internal) Networking module (See Note 1) Isolated RS232 module Isolated RS485 module 70W Power supply Housing base Redundancy module

92

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2) CS1140 This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 126h/01 LPCB Ref. No.

Control and indicating equipment Comprising the following products: CC1140 Control and indicating equipment CT11 Operators console CI1140 Integrated central unit Incorporating as modular units: E3X100 Master module E3X102 Master Module E3X103 Master Module E3X120 Master card Cl1145 E3C010 Battery charging module E3C011 Battery charging module B2F020 Converter B2F040 Converter E3M140 Line module FD20 E3M070 Line module "Interactive" E3M071 Line module Interactive K3M140 Line card FD20 K3M071 Line card Interactive to E3X120 K3M080 Line card Collective B3Q460 Control console Algopilot "CT11" B3Q321 Fire department control panel (Swiss) E3G050 Contacts control unit E3G070 Universal control unit E3I020 RS232 unit K3I060 RS232 module E3L020 I/O control unit E3M080 Group line unit K3R071 Synoptic - Algo pilot K3R070 Synoptic - Algo pilot K3I050 LON/Synoptic converter E3M060 MS9i module E3G091 Remote TX i/face E3M110 AnalogPLUS module E3M111 Line module AnaloguPLUS K3M111 Line card AnalogPLUS B3R051 Parallel indicator panel (24 x 2 LED) E3G080 Control module Extinguishing B3Q440 Control console Extinguishing module E3G060 Control monitored module E3H020 C-Bus Gateway module E3I040 I-Bus/LON module B3Q560/B3Q600 Terminals China B3Q580 Text display terminal B3Q590 Text control terminal Nordic B3Q660 Operator console Standard Algopilot "CT11" B3Q661 Operator console Standard Algopilot "CT11" B3Q680 Control console Nordic Algopilot "CT11" B3Q565 Operator control Asia Pacific Algopilot "CT11" K3N010 RAM - Extension K3I110 LON Input/Output Box E3M171 Line Module Ex Interactive K5L020 Multi-Sect. Extinguishing P.C.B K3G060 Relay Card to Synptic BUS E3G100 Emergency Operation Link E3G110 Emergency Link to E3G080 K3R072 Synoptical Driver M3C080 Horn Monitoring Module Certified with the following Options with requirements from EN 54-2:1997 7.8 Outputs to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to Fire Protection Equipment 7.11 Delays to outputs 7.12 Coincidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.4 Complete failure of power supply 9.5 Disablement of addressable points

12 Sep 2011

93

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 10 11 Test condition Standardised input/output interface LPCB Ref. No.

Notes: 1) Compliance with clause 12.6.2 of EN 54-2:1997 requires LCD screen saving feature to be disabled for the alarm condition.

SMS
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: Nikki.Morgan@honeywell.com Website: www.gent.co.uk
Certificate No: 042bc to EN 54-2: 1997+ A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products Sentri1 Single loop analogue addressable control and indicating equipment Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Spanish language variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Single loop analogue addressable control and indicating equipment (Portuguese language variant) Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface) Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition Two loop analogue addressable control and indicating equipment (English language) Two loop analogue addressable control and indicating equipment (Portuguese language variant) Two loop analogue addressable con(Spanish language variant) control and indicating equipment Incorporating as modular units: 2434-859 2434-862 2434-762 2434-669 4374-164 Master Controller Board (MCB) Power Supply Unit Display and Key card (DKC) Loop processor card Text Membrane (English) LPCB Ref. No. 042bc/01

Sentri1-SP

042bc/02

Sentri1-PO

042bc/03

Sentri2 Sentri2-PO Sentri2-SP

042bc/04 042bc/05 042bc/06

94

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 4374-169 Text Membrane (Spanish) 4374-170 Text Membrane (Portuguese) 2434-861 Copper network card Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition One to Four loop analogue addressable control and indicating equipment (English language) One to Four loop analogue addressable control and indicating equipment (Portuguese language variant without printer module) One to Four loop analogue addressable control and indicating equipment (Spanish language variant without printer module) Incorporating as modular units 2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-167 Text Membrane (English) 4374-171 Text Membrane (Spanish) 4374-172 Text Membrane (Portuguese) 2434-674 Copper network card Scope of approval does not include the operation of the network card) Certified with the following options with requirements from EN 54 Part 2: 7.8 7.11 8.3 9.5 10 Output to fire alarm devices Delays to outputs Fault signals from points Disablement of each address point Test condition LPCB Ref. No.

Sentri4 Sentri4-PO Sentri4-SP

042bc/07 042bc/09 042bc/10

Thorn Security Limited, Trading as Tyco Safety Product


Hanworth Road, Sunbury on Thames, London TW16 5DB, United Kingdom Tel: 01932 743268 Fax: 01932 743292 E-mail: rdhadda@tycoint.com Website: www.Tycoemea.com
Certificate No: 018c-(cl-3) to EN54-2: 1997, EN54-4: 1997 Certificate No: 018f-(cl-1) to EN 54-2: 1997 + A1: 006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 018g-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 018h-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 018j-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 018k-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 Certificate No: 018m-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006

Control & Indicating Equipment


Certificated Products MZXC+ 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices LPCB Ref. No. 018c/02

12 Sep 2011

95

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit LPCB Ref. No.

MZXC+

018c/03

MZXC+

018c/04

MZXC+

018c/05

MZXC+

018c/06

MZXC+

018c/R01

MZXC+

018c/R02

96

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface 2-8 loop Analogue Addressable Control and Indicating Equipment Note: 1. The following product variants are approved Finished goods No. 557.200.003, MX4000 1-4 loop CIE, shallow housing Finished goods No. 557.200.005, MX-BBX battery box, shallow housing Finished goods No. 557.200.004, MX4000 1-8 loop CIE, deep housing Finished goods No. 557.200.006, MX-DPBX battery box, deep housing (door access) Finished goods No. 557.200.016, MX-DPBX battery box, deep housing (plain cover access) Finished goods No. 557.200.009, MX4000 1-4 loop, flush housing Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing Incorporating as modular units: OCM800 ODM800 CPU800 FIM802 PSU830 Operator Control Module Operator Display Module Main CPU module Field Interface Module drives 1 or 2 loops Power Supply Module LPCB Ref. No.

MZXC+

018c/R03

MX4000 2-8

018f/01

and as optional modular units: XLM800 ANN840 ANN880 COM820 MPM800 IOB800 FB800 Expansion Loop Module drives 1 or 2 additional loops 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board

MXR

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Repeater panel is approved for use with the MX4000 Control and Indicating Equipment: Note: 1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module)

018f/R01

12 Sep 2011

97

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products PSU830 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 1 loop Analogue Addressable Control and Indicating Equipment Note: 1. The following product variants are approved Finished goods No. 557.200.001, MX1000 1 loop CIE, shallow housing Finished goods No. 557.200.005, MX-BBX battery box, shallow housing Finished goods No. 557.200.002, MX1000 1 loop CIE, deep housing Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing Incorporating as modular units: OCM800 ODM800 CPU800 FIM801 PSU830 Operator Control Module Operator Display Module Main CPU module Field Interface Module Power Supply Module LPCB Ref. No.

MX1000

018g/01

and as optional modular units: ANN840 ANN880 COM820 MPM800 IOB800 FB800 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface MXR Repeater panel is approved for use with the MX1000 Control and Indicating Equipment (LPCB Reference 018f/R01): Note: 1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator)

98

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 1-8 loop Analogue Addressable Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.203, MX2-210 1-4 loop CIE, shallow housing Finished goods No. 557.200.205, MX2-211, 1-8 loop CIE, deep housing Incorporating as modular units: DCM800 CPU800 FIM802 PSU830 Operator Control / Display Module Main CPU module Field Interface Module drives 1 or 2 loops Power Supply Module LPCB Ref. No.

MX2

018h/01

and as optional modular units: XLM800 ANN881 MPM800 FB800 Expansion Loop Module drives 1 or 2 additional loops 80 LED Annunciator module Multi Purpose Interface Module Fuse Board

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface MXR Repeater panel is approved for use with the MX2 Control and Indicating Equipment (LPCB Reference 018f/R01): Notes: 1. The following product variants are approved Finished goods No. 557.200.013, MXR-PSU repeater Finished goods No. 557.200.018, MXR-PSU-F repeater flush housing Finished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 2-8 loop Analogue Addressable Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.600, T2000 2-8 loop CIE, stainless housing Finished goods No. 557.200.602, T2000-BB battery box, stainless housing Finished goods No. 557.200.610, T2000 2-8 loop CIE, mild steel housing

T2000

018j/01

12 Sep 2011

99

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Finished goods No. 557.200.605, T2000-BB battery box, mild steel housing Incorporating as modular units: OCM800 ODM800 CPU800 FIM802 PSU830 Operator Control Module Operator Display Module Main CPU module Field Interface Module drives 1 or 2 loops Power Supply Module LPCB Ref. No.

and as optional modular units: XLM800 ANN840 ANN880 COM820 MPM800 IOB800 FB800 Expansion Loop Module drives 1 or 2 additional loops 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface T2000R Repeater panel is approved for use with the T2000CV Control and Indicating Equipment (LPCB Reference 018j/R01): Notes 1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing Incorporating as modular units: OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Repeater panel is approved for use with the T2000 Control and Indicating Equipment: Notes: 1. The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing Incorporating as modular units:

T2000R

018j/R01

100

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products OCM800 (Operator Control Module) ODM800 (Operator Display Module) PSU830 (Power Supply Module) and as optional modular units: ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) 3 loop Analogue Addressable Control and Indicating Equipment Notes: 1. The following product variants are approved Finished goods No. 557.200.620, T2000CV 3 loop CIE Finished goods No. 557.200.605, T2000-BB battery box Incorporating as modular units: OCM800 ODM800 CPU800 XLM800 FIM802 PSU830 Operator Control Module Operator Display Module Main CPU module Expansion Loop Module drives 1 or 2 additional loops Field Interface Module drives 1 or 2 loops Power Supply Module LPCB Ref. No.

T2000CV

018k/01

and as optional modular units: ANN840 ANN880 COM820 MPM800 IOB800 FB800 40 + 40 LED Annunciator module 80 LED Annunciator module 20 way Status Command Module Multi Purpose Interface Module Input/Output Expansion Board Fuse Board

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface T2000R Repeater panel is approved for use with the T2000CV Control and Indicating Equipment (LPCB Reference 018j/R01): Notes: 1) The following product variants are approved Finished goods No. 557.200.601, T2000R (AC) repeater stainless housing Finished goods No. 557.200.604, T2000R (DC) repeater stainless housing Finished goods No. 557.200.611, T2000R (AC) repeater mild steel housing Finished goods No. 557.200.612, T2000R (DC) repeater mild steel housing Incorporating as modular units: OCM800 ODM800 PSU830 (Operator Control Module) (Operator Display Module) (Power Supply Module)

and as optional modular units:

12 Sep 2011

101

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products ANN840 (40 + 40 LED Annunciator) ANN880 (80 LED Annunciator) MPM800 (Multi Purpose Interface Module) IOB800 (Input/Output Expansion Board) FB800 (Fuse Board) Analogue Addressable Control and Indicating Equipment 1 loop, 16 Zone Incorporating as modular units: DCM816 CPU800 FIM801 PMM800 BAQ60T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Power Supply LPCB Ref. No.

MZX-125

018m/01

MZX-250

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone Incorporating as modular units: DCM832 CPU800 FIM801 PMM800 BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Power Supply

018m/02

and as an optional modular unit: IOB800 Input/Output Expansion Board

MZX-251

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone Incorporating as modular units:

018m/03

102

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products DCM832 CPU800 FIM801 PMM800 BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Power Supply LPCB Ref. No.

and as an optional modular unit: IOB800 Input/Output Expansion Board

MZX-250-CH

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone Incorporating as modular units: DCM832 CPU800 FIM801 PMM800 FBF-CH BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Swiss Fire Brigade Interface Power Supply

018m/04

and as an optional modular unit: IOB800 Input/Output Expansion Board

MZX-251-S

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone Incorporating as modular units: DCM832 -S Operator Control / Display Module (Scandinavian Fire Brigade Interface/key) CPU800 Main CPU module FIM801 Field Interface Module PMM800 Power Supply Monitor

018m/05

12 Sep 2011

103

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products BAQ140T24 Power Supply LPCB Ref. No. and as an optional modular unit: IOB800 Input/Output Expansion Board

MZX-252

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2 loop, 32 Zone Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Power Supply

018m/06

and as an optional modular unit: IOB800 Input/Output Expansion Board

MZX-252-CH

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Analogue Addressable Control and Indicating Equipment 2 loop, 32 Zone Incorporating as modular units: DCM832 CPU800 FIM802 PMM800 FBF-CH BAQ140T24 Operator Control / Display Module Main CPU module Field Interface Module Power Supply Monitor Swiss Fire Brigade Interface Power Supply

018m/07

and as an optional modular unit: IOB800 Input/Output Expansion Board

104

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency) 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface 16 Zone Repeater Panel, is approved for use with the MZX-125 Control and Indicating Equipment Incorporating as modular units: DCM816 Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply 32 Zone Repeater Panel, is approved for use with the MZX-250, MZX-250-CH, MZX-251, MZX-252 & MZX-252-CH Control and Indicating Equipment Incorporating as modular units: DCM832 Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply 32 Zone Repeater Panel, is approved for use with the MZX-251-S Control and Indicating Equipment Incorporating as modular units: DCM832-S Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply LPCB Ref. No.

MZX-16-R

018m/R01

MZX-32-R

018m/R02

MZX-32-SR

018m/R03

UTC Fire & Security (Africa) trading as Ziton


Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa Tel: +27 21 5066000 Fax: +27 21 5066100 Website: www.utcfireandsecurity.com UK Sales Enquiries: Tel: +44 (0)1908 281981 Fax: +44 (0)1908 282554

Certificate No: 092h to EN 54: Part 2 and 4:1997 Certificate No: 018c to EN 54: Part 2 and 4: 1997 Certificate No: 092e to BS 5839-4: 1988 This certificate is to a withdrawn standard. Control and indicating equipment conforming to this version of the standard is not suitable for use within the jurisdiction of the European Union (EU). This certification, to the withdrawn version of the standard, is maintained because control and indicating equipment meeting the withdrawn version of the standard is still requested by some regulators outside of the EU. Certificate No: 092v to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006 Certificated Products ZC3-EN2 2 zone conventional control and indicating equipment LPCB Ref. No. 018c/02

12 Sep 2011

105

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone Expansion board C1652 5A Power supply board C1631 Repeater interface board (option) Certificated with the following options from EN 54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 8.9 Output to fault routing equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 16 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface board (option) 2,4 and 8 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP-PS230V4A-3 power supply unit LPCB Ref. No.

ZC3-EN4

018c/03

ZC3-EN8

018c/04

ZC3-EN16

018c/05

ZC3-EN32

018c/06

ZC3-RDU230-8

018c/R01

ZC3-RDU230-16

018c/R02

ZC3-RDU230-32

018c/R03

ZP5 Mark 5

092e/01

106

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products ZP-MCB5 main control board ZP-LD8-4 line driver board ZP-DU81L-2 LCD ZP-DU81P-2 plasma display board ZP-PR1 printer kit ZP-RL8-1 8 way programmable relay board Note: This product is certificated to a withdrawn standard. Control and indicating equipment conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 1, 2 and 4 loop analogue addressable control and indicating equipment Incorporating as modular units: ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus drive ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-xL 230V ac Power supply unit Approved with the following options from EN54-2: 7.8 Output to fire alarm devices 7.9 Output to fire alarm routing equipment 7.10 Output to fire protection equipment 7.11 Delays to outputs 7.12 Co-incidence detection 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault routing equipment 9.5 Disablement of addressable points 10.0 Test condition 11.0 Standardised input/output interface Conventional two zone control and indicating equipment Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-20 2A Power Supply Certified with the following options with requirements from EN 54-2: 7.8 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Delays to outputs Total loss of the power supply Test condition LPCB Ref. No.

ZP3

092h/01

1X-F2

092v/01

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/01

1X-F2-SC

Conventional two zone control and indicating equipment with Scandinavian key switch Incorporating the following units: 1X-F2-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key

12 Sep 2011

107

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54-2: 7.8 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Delays to outputs Total loss of the power supply Test condition LPCB Ref. No.

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available in the following language variants: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/02

1X-F4

Conventional four zone control and indicating equipment Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-20 2A Power Supply Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Total loss of the power supply Test condition This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International)

1X-F4-NL

Conventional four zone control and indicating equipment with alarm counter Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-20 2A Power Supply 2010-1-AC Alarm Counter Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 7.13 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Alarm counter Total loss of the power supply Test condition

092v/02

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International)

108

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 1X-F4-SC Conventional four zone control and indicating equipment with Scandinavian key switch Incorporating the following units: 1X-F4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-20 2A Power Supply 2010-SK Scandinavian Key Lock and Key Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Total loss of the power supply Test condition LPCB Ref. No. 092v/02

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/03

1X-F8

Conventional eight zone control and indicating equipment Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-40 4A Power Supply Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Total loss of the power supply Test condition

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/03

1X-F8-NL

Conventional eight zone control and indicating equipment with alarm counter Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 7.13 8.4 10 Notes: 1. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Alarm counter Total loss of the power supply Test condition

This product approval does not constitute compliance with the fire detection

12 Sep 2011

109

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/03 LPCB Ref. No. 2.

1X-F8-SC

Conventional eight zone control and indicating equipment with Scandinavian key switch Incorporating the following units: 1X-F8-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-40 4A Power Supply 2010-SK Scandinavian Key Lock and Key Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Total loss of the power supply Test condition

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/04

1X-E4

Conventional four zone control and indicating equipment with evacuation zones Incorporating the following units: 1X-E4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-40 4A Power Supply Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Total loss of the power supply Test condition

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/04

1X-E4-NL

Conventional four zone control and indicating equipment with evacuation zones and alarm counter Incorporating the following units: 1X-E4-MB Main control board 2010-1-RB Optional relay board 2010-1-SB Optional expander I/O board 2010-PS-40 4A Power Supply 2010-1-AC Alarm Counter

110

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.11 7.13 8.4 10 Notes: 1. 2. Output to fire alarm device(s) Output to fire alarm routing equipment Delays to outputs Alarm counter Total loss of the power supply Test condition LPCB Ref. No.

This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/05

2X-F1

1 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/05 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F1-FB

1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB Network board Interface Board for External Printer

12 Sep 2011

111

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/05 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F1-SC

1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F1-MB 2X-UI-SC controls 2010-2-PS-40 and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly Main control board User interface control board with fire routing 4A Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

112

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable LPCB Ref. No.

2X-F2

092v/06

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/06 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F2-FB

2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter

12 Sep 2011

113

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/06 Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

2X-F2-SC

2 loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/07 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F1-S

1 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB Network board Loop expansion board Interface board for external printer

114

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2X-ZI-24 2010-2-PS-C2 24 zone LED indication board UK mains cable LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable 1. Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F1-FB-S

092v/08

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 - Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 - Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 - Catalan, 99 English (International) 092v/09 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F1-SC-S

1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet

12 Sep 2011

115

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F2-S

2 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

116

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F2-FB-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable 092v/11 LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 - Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 Estonian, 31 - Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 - Catalan, 99 - English (International) 2X-F2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key Incorporating the following units: 2010-2-F2-MB 2X-UI-SC 2010-2-PS-40 2010-SK and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Main control board User interface control board with fire routing controls 4A Power Supply Scandinavian key and lock assembly 092v/12 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment

12 Sep 2011

117

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/R01 Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

2X-FR

Addressable Fire Panel Repeater Incorporating the following option with requirements: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment Incorporating the following option with requirements: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key Incorporating the following option with requirements: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater in small cabinet Incorporating the following option with requirements: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet Incorporating the following option with requirements: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet Incorporating the following option with requirements:

2X-FR-FB

092v/R02

2X-FR-SC

092v/R03

2X-FR-S

092v/R04

2X-FR-SC-S

092v/R05

2X-FR-FB-S

092v/R06

118

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

UTC Fire & Security Americas Corporation, Inc.


129 North Main Street, Pittsfield, ME 04967, United States Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com
Certificate No: 262v to EN 54: Part 2 and 4: 1997 Certificated Products EST3 Repeater Incorporating as modular units: 3-RS485BA Remote Annunciator RS485 Communications. 3-ANNCPU3 Remote Annunciator CPU 3-LCDANN-E LCD Display and User Interface for Remote Annunciator 3-ANNSM Remote (repeater) Annunciator Support Module 3-REMICA Remote paging Microphone 3-24Y 24, Yellow 3-12/S1GY 12 Switches. Green over-yellow pairs 3-6ANN-E(R) Remote Annunciator Back Box, 6 slots, with Door (R) indicates red 3-10ANN-E(R) Remote Annunciator Back Box, 10 slots, with Door (R) indicates red Certified with the following options with requirements from EN 54 Part 2: 7.8 7.13 8.3 10 Notes: 1. Scope of approval does not include system compatibility. EST3 Control and indicating equipment Incorporating as modular units: 3-SSDC1-E Signature (Single), driver controller module 3-SDDC1-E Signature (Dual), driver controller module 3-AADC1-E System Sensor driver control module 3-EASC-E Edwards (Single) Analogue driver controller module 3-EADC-E Edwards (Dual) Analogue driver controller module 3-PPS/M-230-E Primary Power Supply 3-BPS/M-230-E Booster Power Supply 3-BBC/M-230-E Booster Battery Charger Power Supply 3-ASU Audio Source Unit 3-ASU/FT-E Audio Source Unit with Fire Fighter Telephone 3-ASUMX/100 100 minute extended audio memory card 3ASU/4 Audio Source Unit with 4 Local Rail Modules (LRM) slots 3-ZA20A 20 watt Zone Amplifier, Class A 3-ZA20B 20 watt Zone Amplifier, Class B 3-ZA40A 40 watt Zone Amplifier, Class A 3-ZA40B 40 watts Zone Amplifier, Class B 3-CPU3 Central Processor Unit EFM-2 Data Communications Filter 3-ZA95 95 watt Zone Amplifier, Class A 3-CAB7-E 7 Slot Cabinet 3-CAB14-E 14 Slot Cabinet 3-CAB21-E 21 Slot Cabinet 262v/01 Output to fire alarm devices Alarm counter Fault Signals from points. Test condition LPCB Ref. No. 262/v01R

12 Sep 2011

119

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 3-CAB7D(R)-E Door for 7 Slot Cabinet, (R) indicates red 3-CAB14D(R)-E Door for 14 Slot Cabinet, (R) indicates red 3-CAB21D(R)-E Door for 21 Slot Cabinet, (R) indicates red 3-RCC7R-E Small Remote Battery Cabinet 3-RCC14R-E Medium Remote Battery Cabinet 3-RCC21R-E Large Remote Battery Cabinet 3-LCD Liquid Crystal Display, user interface 3-BATSEN-E Remote battery cabinet interface, temperature sensing 3-BATSEN Remote battery cabinet interface 3-BATS Battery Shelf 3-RS485A Data Communication, Class A 3-RS485B Data Communication, Class B 3-RS232 Serial Communications Card (Printer, etc) 3-PSMON Primary Power Supply Monitor 3-IDC8/4 Initiating Device Circuits/NACS 3-24R 24, Red 3-24Y 24, Yellow 3-24G 24, Green 3-12RY Red-over-yellow pairs 3-12SR 12 Switches. Red 3-12SY 12 Switches. Yellow 3-12SG 12 Switches. Green 3-12/S1GY 12 Switches. Green over-yellow pairs 3-12/S1RY 12 Switches. Red over-yellow pairs 3-12/S2Y 24, Yellow, 12 Switches 3-12/S2R 24, Red, 12 Switches 3-6/3S1G2Y Green-over-yellow-over-yellow triads, 6 triads 3-6/3S1GYR Green-over-yellow-over-red triads, 6 triads 3-6/3S2RY Red-over-yellow-over-red triads, 6 triads 3-BBCMON Booster, Battery Charger Monitor 3-BPSMON Booster Power supply Monitor 3-LDSM Annunciator strip support module 3-LRMF Local Rail Module Filler 3-FTCU MB Fire fighter Telephone Control Unit MB. 3-FTCU-E Fire fighter Telephone Control Unit Display. 3-REMICP Remote Microphone, Panel. 3-RCIC ASU Interconnect power and rail communication unit LPCB Ref. No.

UTC Fire & Security BV


Kelvinstraat 7, NL-6003DH, Weert, Netherlands Tel: + 31 495 58 30 00 Fax: + 31 495 55 00 42 E-mail: Daragh.O'Donnell@fs.utc.com Website: www.utcfireandsecurity.com
Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Unbranded - 2X
Certificated Products 2X-F1 1 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable LPCB Ref. No. 092v/05

Certified with the following options with requirements from EN 54-2:

120

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Interface Board for External Printer Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable 1. Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

2X-F1-FB

092v/05

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/05 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F1-SC

1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply

12 Sep 2011

121

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F2

2 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language variants: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

122

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F2-FB 2 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable 092v/06 LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language variants: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/06 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F2-SC

2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment

12 Sep 2011

123

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/07 Disablement of addressable points Test condition LPCB Ref. No.

2X-F1-S

1 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/08

2X-F1-FB-S

1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2:

124

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/09 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

2X-F1-SC-S

1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F2-S

2 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units:

12 Sep 2011

125

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2010-2-F2-MB 2X-UI 2010-2-PS-40 and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Main control board User interface control board 4A Power Supply Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/11 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-F2-FB-S

2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

126

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-F2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key Incorporating the following units: 2010-2-F2-MB Main control board 2X-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 2010-SK Scandinavian key and lock assembly and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable 092v/12 LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 2X-FR Addressable Fire Panel Repeater Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater in small cabinet Incorporating the following options with requirements from EN 54-2: 092v/R01 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

2X-FR-FB

092v/R02

2X-FR-S

092v/R03

12 Sep 2011

127

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

2X-FR-SC

092v/R03

2X-FR-SC-S

092v/R05

2X-FR-FB-S

092v/R06

Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Aritech - KFP
Certificated Products KFP-AF1 1 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable LPCB Ref. No. 092v/05

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

128

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/05 LPCB Ref. No.

KFP-AF1-FB

1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Interface Board for External Printer Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/05 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

KFP-AF1-SC

1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly

12 Sep 2011

129

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

KFP-AF2

2 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available in the following language variants: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/06 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

KFP-AF2-FB

2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F2-MB Main control board

130

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products KFP-A-UI-FB 2010-2-PS-40 and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable User interface control board with fire routing controls 4A Power Supply LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 Dutch, 02 French, 03 English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 French International, 45 Romanian, 71 Catalan, 99 - English (International) 092v/06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

KFP-AF2-SC

2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

12 Sep 2011

131

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/07 LPCB Ref. No.

KFP-AF1-S

1 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/08

KFP-AF1-FB-S

1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C)

132

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/09 Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

KFP-AF1-SC-S

1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

KFP-AF2-S

2 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply

12 Sep 2011

133

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. 2. 3. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. Scope of approval does not include the operation of the network functionality. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) 092v/11 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

KFP-AF2-FB-S

2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

134

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Catalan, 99 - English (International) KFP-AF2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key Incorporating the following units: 2010-2-F2-MB Main control board KFP-A-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 2010-SK Scandinavian key and lock assembly and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable 092v/12 LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) KFP-AFR Addressable Fire Panel Repeater Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 Alarm counter Total loss of the power supply Output to fault warning routing equipment 092v/R01 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

KFP-AFR-FB

092v/R02

KFP-AFR-SC

092v/R03

12 Sep 2011

135

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No. 092v/R04

KFP-AFR-S

KFP-AFR-SC-S

092v/R05

KFP-AFR-FB-S

092v/R06

Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Ziton - ZP2
Certificated Products ZP2-F1 1 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F1-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board 2-Loop Node Card Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable LPCB Ref. No. 092v/05

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

136

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-FB 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-232-IB 2010-2-LB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Interface Board for External Printer Loop expansion board 20 zone LED indication board 40 zone LED indication board UK mains cable 092v/05 LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-SC 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly 092v/05 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Certified with the following options with requirements from EN 54-2:

12 Sep 2011

137

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2 2 Loop intelligent analogue addressable control and indicating equipment Incorporating the following units: 2010-2-F2-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable 092v/06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Type A, B and C) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available in the following language variants: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-FB 2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 092v/06 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Type A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

138

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-SC 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-20 2X-ZI-40 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface Board for External Printer 20 zone LED indication board 40 zone LED indication board UK mains cable Scandinavian key and lock assembly 092v/06 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

12 Sep 2011

139

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-S 1 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB Network board 2010-2-LB Loop expansion board 2010-2-232-IB Interface board for external printer 2X-ZI-24 24 zone LED indication board 2010-2-PS-C2 UK mains cable Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition 092v/07 LPCB Ref. No.

Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-FB-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable 092v/08

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply

140

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F1-SC-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet Incorporating the following units: 2010-2-F1-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 2010-SK Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable Scandinavian key and lock assembly 092v/09 Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-S 2 Loop intelligent analogue addressable fire control panel in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board ZP-UI User interface control board 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 Network board Loop expansion board Interface board for external printer 24 zone LED indication board 092v/10 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

12 Sep 2011

141

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 2010-2-PS-C2 UK mains cable LPCB Ref. No. Certified with the following options with requirements from EN 54-2: 7.8 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-FB-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-FB User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable 092v/11 Output to fire alarm device(s) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-F2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key 092v/12 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

142

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating the following units: 2010-2-F2-MB Main control board ZP2-UI-SC User interface control board with fire routing controls 2010-2-PS-40 4A Power Supply 2010-SK Scandinavian key and lock assembly and as optional modules: 2010-2-NB 2010-2-LB 2010-2-232-IB 2X-ZI-24 2010-2-PS-C2 Network board Loop expansion board Interface board for external printer 24 zone LED indication board UK mains cable LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 7.9.1 7.9.2 7.10 7.11 7.12 7.13 8.4 8.9 9.5 10 Notes: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality. 3. Available with the following language kits: 01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 Catalan, 99 - English (International) ZP2-FR Addressable Fire Panel Repeater Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Output to Fire Routing Equipment Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with Scandinavian Key Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater in small cabinet Incorporating the following options with requirements from EN 54-2: 092v/R01 Output to fire alarm device(s) Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Output to fire protection equipment (Types A, B and C) Delays to outputs Dependencies on more than one alarm signal (Types A, B and C) Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition

ZP2-FR-FB

092v/R02

ZP2-FR-SC

092v/R03

ZP2-FR-S

092v/R04

12 Sep 2011

143

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 Alarm counter 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet Incorporating the following options with requirements from EN 54-2: 7.13 8.4 8.9 9.5 10 Alarm counter Total loss of the power supply Output to fault warning routing equipment Disablement of addressable points Test condition LPCB Ref. No.

ZP2-FR-SC-S

092v/R05

ZP2-FR-FB-S

092v/R06

Xtralis Pty Limited


4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, Australia Tel: +61 3 9936 7001, +44 (0)1442 242330 Fax: +61 3 9936 7201 E-mail: marketing-emea@xtralis.com Website: www.xtralis.com
Certificate No: 305f to EN 54-4: 1997 + A1: 2002 + A2: 2006

Power Supply Unit


Certificated Products VPS-215-U VPS-220-U 516-018-407 Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels Power Supply Unit Note: The unit is not intended to supply power to Fire Alarm Control Panels LPCB Ref. No. 305f/01 305f/02 305f/03

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 330d to EN 54: Part 2 and 4: 1997 Certificated Products Premier SX Premier SX Premier SX Premier SX Premier SX 1 zone conventional control and indicating equipment 2 zone conventional control and indicating equipment 4 zone conventional control and indicating equipment 6 zone conventional control and indicating equipment 8 zone conventional control and indicating equipment LPCB Ref. No. 330d/01 330d/02 330d/03 330d/04 330d/05

144

12 Sep 2011

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm devices 7.11 Delays to the actioning of outputs 10 Test condition 2 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 4 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 16 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 32 zone conventional control and indicating equipment Incorporating as modular units: C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option) Certified with the following options from EN 54: Part 2 7.8 Output to fire alarm devices 7.9 Output to fire routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to outputs 8.9 Output to fault warning equipment 10 Test condition 8 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 16 zone conventional repeater unit LPCB Ref. No.

Premier MX

330d/06

Premier MX 4

330d/07

Premier MX 8

330d/08

Premier MX 16

330d/09

Premier MX 32

330d/10

Premier MX Repeater 8

330d/R01

Premier MX Repeater 16

330d/R02

12 Sep 2011

145

PART 1: SECTION 3
CONTROL AND INDICATING EQUIPMENT
Certificated Products Incorporating as modular units: C1627 Mother board C1628 Display board C1631 Repeater interface 32 zone conventional repeater unit Incorporating as modular units: C1627 Mother board C1629 Display board C1631 Repeater interface LPCB Ref. No.

Premier MX Repeater 32

330d/R03

Certificate No: 018c to EN 54-2 and 4:1997 Certificated Products Prem1er AL 4 loop analogue addressable control and indicating equipment Incorporating: A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230V AC power supply control card A1599 Printer board Certified with the following options from EN 54-2: 1997 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of addressable points 10 Test condition LPCB Ref. No. 018c/01

146

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS There are many types of detectors on the market designed to work on different principles and fire parameters (e.g. smoke, flame radiation, convective heat etc). The selection of a detector for a particular area or application should be based on a number of factors including the following: The nature of the fire hazard The speed of response required The need to minimize false alarms

There are other factors to be taken into account such as architecture of the building, ease of maintenance and cost. Guidance on the selection of appropriate types of detectors should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). Where a particular type of detector is not covered by the installation rule or code of practice then guidance should be sought from the manufacturers literature. In any case, account should be given to the notes or limitations given with the listed detector in this section. This section lists fire detectors approved for use in fire detection and fire alarm systems in buildings. The initial approval and continued approval processes for detectors are outlined in scheme document SD021. The list includes detectors certified to recognised standards or to special test schedules which are developed by LPCB for detector types where suitable standards are not available or were not available at the time of the evaluation. Products listed in this section have been approved to: EN 54-5: 2000 Heat detectors - point detectors EN 54-5: 2000 + A1: 2002 Heat detectors - point detectors EN 54-7: 2000 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-7 :2000 +A1: 2002 and A2: 2006 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-10: 2002 Flame detectors - point detectors EN 54-10: 2002 + A1: 2005 Flame detectors - point detectors EN 54-12: 2002 Smoke detectors - line detectors using an optical light beam EN 54-20: 2006 Aspirating smoke detectors ISO7240-5: 2003 Point -type heat detectors ISO7240-6: 2004 Carbon monoxide fire detectors using electro-chemical cells ISO7240-7: 2003 Point-type smoke detectors using scattered light, transmitted light or ionization ISO7240-12: 2005 Line type smoke detectors using transmitting light beam ISO7240-15: 2004 Multisensor fire detectors ISO 7240-6: 2008 Carbon monoxide fire detectors using electro-chemical cells and heat sensors. CEA 4021: 1999 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor CEA 4021: 2003 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor LPS 1265-1.1: 2005 Requirements and Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide Fire Detectors Using Electrochemical Cells LPS 1274-1.0: 2005 Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide / Heat Multisensor Fire Detectors Using Electrochemical Cells LPS 1279: 2006 Testing Procedures for the LPCB Approval and Listing of Point Multisensor Fire Detectors using Optical or Ionization Smoke Sensors and Electrochemical Cell CO Sensors and, optionally, Heat Sensors

Approval can also be obtained for other detection principles not detailed above. In such circumstances, LPCB can develop test criteria to evaluate products, which in time may be used for the development of standards. Audit:

12 Sep 2011

147

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-5: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that heat detectors are certificated to EN 54-5: 2000 + A1: 2002 2. EN 54-7: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that smoke detectors are certificated to EN 54-7: 2000 + A1: 2002 and A2: 2006 3. EN 54-10: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 September 2008. It is therefore recommended that flame detectors are certificated to EN 54- 10: 2002 + A1: 2005 4. EN 54-12: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 31 December 2005. It is therefore recommended that beam detectors are certificated to EN 54- 12: 2002 5. CEA 4021: 2003 supersedes CEA 4021: 1999 which was withdrawn in June 2003 (i.e. at the same time as the national versions of EN 54-5: 1976 and EN 54-7: 1982 were officially withdrawn and replaced with EN 545: 2000 and EN 54-7: 2000). 6. EN 54-20: 2006 supersedes CEA 4022: 1999 which should have been withdrawn in 2009. EN 54-20: 2006 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 July 2009. It is therefore recommended that aspirating detectors are certificated to EN 54-20: 2006. 7. The bases with which a detector has been evaluated and shown to meet the relevant standards are listed with each detector. Bases are not approved/certificated in their own right unless they are combined with another device (e.g. short circuit isolator or sounder). 8. Since LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

ADI International
ADI International Espana, C/Vivero 5, 28040 Madrid, Spain Tel: +34 91 102 590 Fax: +34 91 535 0081 E-mail: alvazquez@ademco.es Website: www.ademco.es
Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005 Certificate No: 199u to EN 54-12: 2002

Beam Detectors
Certificated Products 8200R Conventional optical beam detector Note: 1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate levels 1 & 2 Conventional optical beam detector with self test facility Note: 1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate levels 1 & 2 Analogue optical beam detector with short circuit isolator feature LPCB Ref. No. 199u/01

8200RS

199u/02

8200

199w/01

148

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 8200S Analogue optical beam detector with self test facility and short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 199w/02 LPCB Ref. No.

Certificate No: 199p to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products 2610TEM Conventional optical/thermal smoke & heat detector (B401, B401DG, B401R, B401SD and B401RSD bases) Note: Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at High, Medium and Low. LPCB Ref. No. 199p/03

Bases: B401 B401DG B401R B401RSD

Standard base Deep base Standard Base with 470 ohm resistor Standard base with 470 ohm resistor and schottky diode

Certificate No: 199m to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products 2610EC Conventional photoelectric detector (B401, B401DG, B401R, B401SD and B401RSD bases) Note: Meets EN 54-7:2000 with low, medium and high sensitivities LPCB Ref. No. 199m/03

Bases: B401 Standard base B401DG Deep base B401R Standard base with 470 ohm resistor B401SD Standard base with schottky diode B401RSD Standard base with 470 ohm resistor and schottky diode

Certificate No: 199n to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products 3610EC 4610EC class A1R conventional rate of rise heat detector (B401, B401DG, B401R and B401RSD bases) class BS conventional heat detector (B401, B401DG, B401R, B401SD and B401RSD bases) LPCB Ref. No. 199n/07 199n/08

Bases: B401 B401DG B401R B401SD B401RSD

Standard base Deep base Standard Base with 470 ohm resistor Standard Base with schottky diode Standard base with 470 ohm resistor and schottky diode

12 Sep 2011

149

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Advanced Electronics Limited


34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0) 1226 737 465 Fax: +44 (0) 1226 737 469 E-mail: ithompson@advel.co.uk Website: www.Advel.co.uk
Certificate No: 928a-(cl-5) to EN54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-5) to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products 20-V350-ADV Analogue addressable Class P heat detector with short circuit isolator (20-AB100-ADV base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. 20-LV350-ADV Analogue addressable Class P, temperature detector (20-VB100-ADV and 20-AB100ADV bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional Class P, heat detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100-ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional photo smoke detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100-ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV 928d/01 LPCB Ref. No. 928a/01

20-AS3500-ADV

928d/02

20-AS1000-ADV

928e/02

Bases 20-AB100-ADV Mounting base 20-VB100-ADV Mounting base (with link resistor) 20-ABR100-ADV Universal adaptor base with resistor 20-ABDR100-ADV Universal adaptor base with resistor and Schottky diode 20-ABS100-ADV Deep adaptor base 20-ABSR100-ADV Deep adaptor base with resistor 20-ABSRD100-ADV Deep adaptor base with resistor and Schottky diode

Certificate No: 928b-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products 20-V100-ADV Analogue addressable photoelectric smoke detector with short circuit isolator (20-AB100ADV base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Analogue addressable optical smoke detector (20-VB100-ADV and 20-AB100-ADV bases) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Conventional photo smoke detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV) LPCB Ref. No. 928b/01

20-LV100-ADV

928e/01

20-AS1000-ADV

928e/02

150

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases 20-AB100-ADV Mounting base 20-VB100-ADV Mounting base (with link resistor) 20-ABR100-ADV Universal adaptor base with resistor 20-ABDR100-ADV Universal adaptor base with resistor and Schottky diode 20-ABS100-ADV Deep adaptor base 20-ABSR100-ADV Deep adaptor base with resistor 20-ABSRD100-ADV Deep adaptor base with resistor and Schottky diode

Certificate No: 928c-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003 Certificate No: 928f-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-sensor detectors
Certificated Products 20-V200-ADV Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (20-AB100-ADV base) Notes 1. LPCB Ref. No. 928c/01

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low 928f/01

20-LV200-ADV

Analogue addressable photo thermal multisensor (20-VB100-ADV and 20-AB100-ADV bases) Notes 1.

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

Bases 20-AB100-ADV Mounting base 20-VB100-ADV Mounting base (with link resistor)

12 Sep 2011

151

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Advantronic Systems S.L.


C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, Spain Tel: +34 91 806 2343 Fax: +34 91 803 1171 E-mail: jpedrouzo@advantronic.es Website: www.advantronic.es
Certificate No: 928a-(cl-3) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-3) to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products AT120A Analogue addressable Class P heat detector with short circuit isolator (BA100 base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Analogue addressable Class P, temperature detector (BA100 base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional Class P, heat detector (BA100 and BA101 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. LPCB Ref. No. 928a/01

AT120AS AT120CM

928d/01 928d/02

Bases BA100 Mounting base BA101 Deep adaptor base

Certificate No: 928b-(cl-3) to 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products AT110A Analogue addressable photoelectric smoke detector with short circuit isolator (BA100 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Analogue addressable optical smoke detector (BA100 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Conventional photo smoke detector (BA100 and BA101 bases) LPCB Ref. No. 928b/01

AT110AS

928e/01

AT110CM Bases BA100 Mounting base BA101 Deep adaptor base

928e/02

Certificate No: 928c-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003 Certificate No: 928f-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-sensor Detectors
Certificated Products AT130A Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (BA100 base) LPCB Ref. No. 928c/01

152

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products LPCB Ref. No. Notes 1.

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low 928f/01

AT130AS

Analogue addressable photo thermal multisensor (BA100 base) Notes 1.

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

Bases BA100 Mounting base

Aguilera Electronica S.L


C / Julian Camarillo 26, Madrid 28037, Spain Tel: +34 917545511 Fax: +34 917545098 E-mail: aguilera@aguilera.es
Certificate No: 512d-(cl-2) to EN 54-5: 2000

Point Heat Detectors


Certificated Products AE/C5-TV Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) LPCB Ref. No. 512d/04

Bases: P/N854001 4-Wire detector base Certificate No: 512a-(cl-2) to EN 54-7: 2000

12 Sep 2011

153

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Point Smoke Detectors
Certificated Products AE/C5-OP Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) LPCB Ref. No. 512a/02

Bases: P/N854001 4-Wire detector base Certificate No: 512b-(cl-1) to EN54-5:2000, EN54-7:2000 & CEA 4021:1999

Multi-criteria Detectors
Certificated Products AE/C5-OPT Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) LPCB Ref. No. 512b/02

Bases: P/N854001 4 Wire detector base

Alarm Supply Pte Ltd


63 Jalan Pemimpin, 03-07 Pemimpin Industrial Building, Singapore 577219, Singapore Tel: +65 625 83445 Fax: +65 625 86428
Certificate No: 512a to EN 54-7: 2000

Smoke Detectors
Certificated Products EA318-2 EA318-2L Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 2 wire photoelectric smoke detector with remote LED output (E300-Base) LPCB Ref. No. 512/01 512a/02

Bases: E300-Base 4-wire detector base P/N852001 2-wire detector base Certificate No: 512d to EN 54-5: 2000

Heat Detectors
Certificated Products EA323-2 EA323-2L/A2R Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (E300-Base) LPCB Ref. No. 512d/02 512d/04

Bases: E300-Base 4-wire detector base P/N852001 2-wire detector base

154

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Apollo Fire Detectors Limited


36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 Fax: +44 (0)2392 492754 E-mail: enquiries@apollo-fire.co.uk Sales Enquiries Germany, Apollo Deutschland GmbH Tel: +49 5241 330 60 Fax: +49 5241 330 629 E-mail: info@apollo-feuer.de

Sales Enquiries Spain, Apollo Espana Tel: +34 627 988 061 Fax: +34 949 335 289 E-mail: apollo.espana@apollo-fire.com

Sales Enquiries China, Apollo Fire Detectors Limited, Shanghai representative office Tel: +86 21 5237 0922 Fax: +86 21 5237 0920 E-mail: tony.ye@apollo-fire.com

Certificate No: 010p to EN 54: Part 5: 2000 Certificate No: 010r to EN 54: Part 5: 2000 Certificate No: 010ab to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products XPA-HT-11170-APO Xpander addressable radio linked Class A1R heat detector (XPA-WB-10022-APO mounting base) Notes: 1) Meets the requirements of EN 54-5 for Class A1R. 2) The complete radio base/detector combination is available as Apollo Part No.: XPACB-11170-APO. 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 4) The radio link functionality of this device is not included within the scope of approval. Xpander addressable radio linked Class CS heat detector (XPA-WB-10022-APO mounting base) Notes: 1) Meets the requirements of EN 54-5 for Class CS. 2) The complete radio base/detector combination is available as Apollo Part No.: XPACB-11171-APO. 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 4) The radio link functionality of this device is not included within the scope of approval. Analogue addressable Class A2S heat detector (45681-500 and 45681-501 mounting bases) Certificated with Apollo Series 90 and XP95 digital communication protocols Analogue addressable Class CS heat detector (45681-500 and 45681-501 mounting bases) Certificated with Apollo Series 90 and XP95 digital communication protocols Analogue addressable heat detector (45681-209 and 45681-210 mounting base)2 Note: Meets the requirements of EN 54: Part 5 for the following settings Class A1R in mode 1 and in conventional mode. Class A2 in mode 2 and in conventional mode. Class A2S in mode 3 and in conventional mode. Class CR in mode 4 and in conventional mode. Class CS in mode 5 and in conventional mode. Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols when the Discovery heat detector has been configured in accordance with manufacturer's LPCB Ref. No. 010ab/01

XPA-HT-11171-APO

010ab/02

59000-400 XPlorer 59000-410 XPlorer 58000-400 Discovery

010p/01 010p/02 010p/03

12 Sep 2011

155

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 55000-120 Series 65 instructions. Conventional Class A1R heat detector - Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class A1R Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class A1R heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class A1R Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class A1R heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class A1R Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class BR heat detector - Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class BR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class BR heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class BR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class BR heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class BR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class CR heat detector- Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class CR heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class CR heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CR Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class CS heat detector - Flashing LED/Reed switch (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CS Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class CS heat detector - Flashing LED (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CS Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional Class CS heat detector - Standard (45681-200 mounting base) Note: Meets the requirements of EN 54: Part 5 - Class CS Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Analogue addressable Class A2S heat detector 45681-209 and 45681-210 mounting base) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. Analogue addressable Class CS heat detector 45681-209 and 45681-210 mounting base) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. Analogue addressable Class A2S heat detector 45681-209 and 45681-210 mounting base) Certificated with Apollo Discovery, XP95, and S90 digital communications protocol configured for the Discovery heat detector in accordance with manufacturers instructions. Analogue addressable intrinsically safe Class A2S heat detector (45681-215 mounting base) Certified with Apollo Series 90 and XP95 digital communications protocol Heat detectors with Apollo Approval Reference* 00001 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-HT-11001-APO Orbis class A1R heat detector with SensAlert and FasTest LPCB Ref. No. 010p/04

55000-121 Series 65

010p/05

55000-122 Series 65

010p/06

55000-125 Series 65

010p/07

55000-126 Series 65

010p/08

55000-127 Series 65

010p/09

55000-130 Series 65

010p/10

55000-131 Series 65

010p/11

55000-132 Series 65

010p/12

55000-135 Series 65

010p/13

55000-136 Series 65

010p/14

55000-137 Series 65

010p/15

55000-400 XP95

010p/20

55000-401 XP95

010p/21

55000-420 XP95

010p/22

55000-440 XP95 IS Orbis Class A1R

010p/23 010r/01

156

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products ORB-HT-11013-APO Orbis class A1R heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11019-APO Orbis class A1R heat detector with SensAlert OPX-HT-11025-APO Orbis class A1R heat detector with SensAlert OEX-HT-11037-APO Orbis class A1R heat detector with Flashing LED and SensAlert OIX-HT-11043-APO Orbis class A1R heat detector with Flashing LED and SensAlert OMX-HT-11049-APO Orbis class A1R heat detector with SensAlert OSX-HT-11061-APO Orbis class A1R heat detector with Flashing LED and SensAlert OMX-HT-11071-APO Orbis class A1R heat detector with Flashing LED and SensAlert OAX-HT-11077-APO Orbis class A1R heat detector with Flashing LED and SensAlert OEX-HT-11089-APO Orbis class A1R heat detector with SensAlert OSX-HT-11095-APO Orbis class A1R heat detector with SensAlert OPX-HT-11125-APO Orbis class A1R heat detector with Flashing LED and SensAlert OLX-HT-11137-APO Orbis class A1R heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00002 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-HT-11002-APO Orbis class A2S heat detector with SensAlert and FasTest ORB-HT-11014-APO Orbis class A2S heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11020-APO Orbis class A2S heat detector with SensAlert OPX-HT-11026-APO Orbis class A2S heat detector with SensAlert OEX-HT-11038-APO Orbis class A2S heat detector with Flashing LED and SensAlert OIX-HT-11044-APO Orbis class A2S heat detector with Flashing LED and SensAlert OMX-HT-11050-APO Orbis class A2S heat detector with SensAlert OSX-HT-11062-APO Orbis class A2S heat detector with Flashing LED and SensAlert OMX-HT-11072-APO Orbis class A2S heat detector with Flashing LED and SensAlert OAX-HT-11078-APO Orbis class A2S heat detector with Flashing LED and SensAlert OEX-HT-11090-APO Orbis class A2S heat detector with SensAlert OSX-HT-11096-APO Orbis class A2S heat detector with SensAlert OPX-HT-11126-APO Orbis class A2S heat detector with Flashing LED and SensAlert OLX-HT-11138-APO Orbis class A2S heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00003 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-HT-11003-APO Orbis class BR heat detector with SensAlert and FasTest ORB-HT-11015-APO Orbis class BR heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11021-APO Orbis class BR heat detector with SensAlert OPX-HT-11027-APO Orbis class BR heat detector with SensAlert OEX-HT-11039-APO Orbis class BR heat detector with Flashing LED and SensAlert OIX-HT-11045-APO Orbis class BR heat detector with Flashing LED and SensAlert OMX-HT-11051-APO Orbis class BR heat detector with SensAlert OSX-HT-11063-APO Orbis class BR heat detector with Flashing LED and SensAlert OMX-HT-11073-APO Orbis class BR heat detector with Flashing LED and SensAlert OAX-HT-11079-APO Orbis class BR heat detector with Flashing LED and SensAlert OEX-HT-11091-APO Orbis class BR heat detector with SensAlert OSX-HT-11097-APO Orbis class BR heat detector with SensAlert OPX-HT-11127-APO Orbis class BR heat detector with Flashing LED and SensAlert OLX-HT-11139-APO Orbis class BR heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00004 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11004-APO Orbis class BS heat detector with SensAlert and FasTest ORB-HT-11016-APO Orbis class BS heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11022-APO Orbis class BS heat detector with SensAlert OPX-HT-11028-APO Orbis class BS heat detector with SensAlert OEX-HT-11040-APO Orbis class BS heat detector with Flashing LED and SensAlert OIX-HT-11046-APO Orbis class BS heat detector with Flashing LED and SensAlert OMX-HT-11052-APO Orbis class BS heat detector with SensAlert OSX-HT-11064-APO Orbis class BS heat detector with Flashing LED and SensAlert OMX-HT-11074-APO Orbis class BS heat detector with Flashing LED and SensAlert OAX-HT-11080-APO Orbis class BS heat detector with Flashing LED and SensAlert OEX-HT-11092-APO Orbis class BS heat detector with SensAlert OSX-HT-11098-APO Orbis class BS heat detector with SensAlert OPX-HT-11128-APO Orbis class BS heat detector with Flashing LED and SensAlert OLX-HT-11140-APO Orbis class BS heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00005 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11005-APO Orbis class CR heat detector with SensAlert and FasTest LPCB Ref. No.

Orbis Class A2S

010r/02

Orbis Class BR

010r/03

Orbis Class BS

010r/04

Orbis Class CR

010r/05

12 Sep 2011

157

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products ORB-HT-11017-APO Orbis class CR heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11023-APO Orbis class CR heat detector with SensAlert OPX-HT-11029-APO Orbis class CR heat detector with SensAlert OEX-HT-11041-APO Orbis class CR heat detector with Flashing LED and SensAlert OIX-HT-11047-APO Orbis class CR heat detector with Flashing LED and SensAlert OMX-HT-11053-APO Orbis class CR heat detector with SensAlert OSX-HT-11065-APO Orbis class CR heat detector with Flashing LED and SensAlert OMX-HT-11075-APO Orbis class CR heat detector with Flashing LED and SensAlert OAX-HT-11081-APO Orbis class CR heat detector with Flashing LED and SensAlert OEX-HT-11093-APO Orbis class CR heat detector with SensAlert OSX-HT-11099-APO Orbis class CR heat detector with SensAlert OPX-HT-11129-APO Orbis class CR heat detector with Flashing LED and SensAlert OLX-HT-11141-APO Orbis class CR heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00006 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11006-APO Orbis class CS heat detector with SensAlert and FasTest ORB-HT-11018-APO Orbis class CS heat detector with Flashing LED, SensAlert and FasTest OAX-HT-11024-APO Orbis class CS heat detector with SensAlert OPX-HT-11030-APO Orbis class CS heat detector with SensAlert OEX-HT-11042-APO Orbis class CS heat detector with Flashing LED and SensAlert OIX-HT-11048-APO Orbis class CS heat detector with Flashing LED and SensAlert OMX-HT-11054-APO Orbis class CS heat detector with SensAlert OSX-HT-11066-APO Orbis class CS heat detector with Flashing LED and SensAlert OMX-HT-11076-APO Orbis class CS heat detector with Flashing LED and SensAlert OAX-HT-11082-APO Orbis class CS heat detector with Flashing LED and SensAlert OEX-HT-11094-APO Orbis class CS heat detector with SensAlert OSX-HT-11100-APO Orbis class CS heat detector with SensAlert OPX-HT-11130-APO Orbis class CS heat detector with Flashing LED and SensAlert OLX-HT-11142-APO Orbis class CS heat detector with SensAlert and FasTest Heat detectors with Apollo Approval Reference* 00009 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base ORB-HT-11166-APO Orbis class A1S heat detector with SensAlert and FasTest ORB-HT-11167-APO Orbis class A1S heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50001 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51145-APO Orbis intrinsically safe class A1R heat detector with SensAlert and FasTest ORB-HT-51146-APO Orbis intrinsically safe class A1R heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50002 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51147-APO Orbis intrinsically safe class A2S heat detector with SensAlert and FasTest ORB-HT-51148-APO Orbis intrinsically safe class A2S heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50003 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51149-APO Orbis intrinsically safe class BR heat detector with SensAlert and FasTest ORB-HT-51150-APO Orbis intrinsically safe class BR heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50004 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51151-APO Orbis intrinsically safe class BS heat detector with SensAlert and FasTest ORB-HT-51152-APO Orbis intrinsically safe class BS heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50005 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51153-APO Orbis intrinsically safe class CR heat detector with SensAlert and FasTest ORB-HT-51154-APO Orbis intrinsically safe class CR heat detector with Flashing LED, LPCB Ref. No.

Orbis Class CS

010r/06

Orbis Class A1S

010r/07

Orbis IS Class A1R

010r/08

Orbis IS Class A2S

010r/09

Orbis IS Class BR

010r/10

Orbis IS Class BS

010r/11

Orbis IS Class CR

010r/12

158

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Orbis IS Class CS SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50006 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base) ORB-HT-51155-APO Orbis intrinsically safe class CS heat detector with SensAlert and FasTest ORB-HT-51156-APO Orbis intrinsically safe class CS heat detector with Flashing LED, SensAlert and FasTest Intrinsically safe heat detectors with Apollo Approval Reference* 50009 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base ORB-HT-51157-APO Orbis intrinsically safe class A1S heat detector with SensAlert and FasTest ORB-HT-51158-APO Orbis intrinsically safe class A1S heat detector with Flashing LED, SensAlert and FasTest Bases: 45681-200 Series 60 mounting base 45681-200 Series 60/65 Mounting Base 45681-201 Series 60 diode mounting base 45681-201 Series 60/65 Diode Mounting Base 45681-207 Series 60 intrinsically safe mounting base 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base 45681-215 XP95 intrinsically safe mounting base 45681-245 Series 65 Relay mounting base 45681-246 Series 65 Auxiliary relay mounting base 45681-247 Series 65 EOL 12 Volt mounting base 45681-248 Series 65 EOL 24 Volt mounting base 45681-500 XPlorer standard mounting base 45681-501 XPlorer remote LED mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) TimeSaver deep bases with Apollo Approval Reference* EB: ORB-MB-00019-APO TimeSaver deep base ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** * The Apollo Approval Reference Number identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS LPCB Ref. No. 010r/13

Orbis IS Class A1S

010r/14

Certificate No: 010q to EN 54: Part 7: 2000 Certificate No: 010s to EN 54: Part 7: 2000 Certificate No: 010ac to EN 54-7: 2000 + A1: 2002

Point Smoke Detectors


Certificated Products XPA-OP-12034-APO Xpander addressable radio linked photoelectric smoke detector (XPA-WB-10022-APO mounting base) Notes: 1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-12034-APO. 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 3) The radio link functionality is not included within the scope of approval. Analogue addressable optical smoke detector (45681-500 and 45681-501 mounting bases) Certificated with Apollo Series 90 and XP95 digital communication protocols Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base)2 Note: Meets the requirements of EN 54:Part 7 in modes 1, 2, 3, 4, 5 and in conventional mode. Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols LPCB Ref. No. 010ac/01

59000-600 Xplorer 58000-500 Discovery

010q/01 010q/02

12 Sep 2011

159

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products that have been configured for the Discovery ionisation smoke detectors has been configured in accordance with manufacturer's instructions. Analogue addressable photoelectric smoke detector (45681-209 and 45681-210 mounting base)2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Conventional ionisation smoke detector - Flashing LED/Reed switch (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional ionisation smoke detector - Flashing LED (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional ionisation smoke detector - Standard (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional integrating ionisation smoke detector - Flashing LED/Reed switch (45681200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional integrating ionisation smoke detector - Flashing LED (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional integrating ionisation smoke detector - Standard (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional optical smoke detector - Flashing LED/Reed switch (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional optical detector - Flashing LED (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Conventional optical smoke detector - Standard (45681-200 mounting base) Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681201 mounting bases Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors in accordance with manufacturers instructions . Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors in accordance with manufacturers instructions . Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery ionisation smoke detectors in accordance with manufacturers instructions . Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base)2 Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions. Analogue addressable intrinsically safe optical smoke detector (45681-215 mounting base) Certified with Apollo Series 90 and XP95 digital communications protocol LPCB Ref. No. 010q/03

58000-600 Discovery

55000-215 Series 65

010q/04

55000-216 Series 65 55000-217 Series 65 55000-218 Series 65

010q/05 010q/06 010q/07

55000-219 Series 65

010q/08

55000-220 Series 65

010q/09

55000-315 Series 65

010q/10

55000-316 Series 65 55000-317 Series 65 55000-500 XP95

010q/11 010q/12 010q/16

55000-520 XP95

010q/17

55000-600 XP95

010q/18

55000-620 XP95

010q/19

55000-560 XP95

010q/20

55000-660 XP95

010q/21

55000-640 XP95 IS

010q/22

160

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 55000-540 XP95 IS Orbis Analogue addressable intrinsically safe ionisation smoke detector (45681-215 mounting base) Certified with Apollo Series 90 and XP95 digital communications protocol Optical smoke detectors with Apollo Approval Reference* 00007 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-OP-12001-APO Orbis optical smoke detector with SensAlert, FasTest and DirtAlert ORB-OP-12003-APO Orbis optical smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert OAX-OP-12004-APO Orbis optical smoke detector with SensAlert OPX-OP-12005-APO Orbis optical smoke detector with SensAlert and DirtAlert OEX-OP-12007-APO Orbis optical smoke detector with Flashing LED and SensAlert OIX-OP-12008-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlert OMX-OP-12009-APO Orbis optical smoke detector with SensAlert and DirtAlert OSX-OP-12011-APO Orbis optical smoke detector with Flashing LED and SensAlert OMX-OP-12013-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlert OAX-OP-12014-APO Orbis optical smoke detector with Flashing LED and SensAlert OEX-OP-12016-APO Orbis optical smoke detector with SensAlert OSX-OP-12017-APO Orbis optical smoke detector with SensAlert OPX-OP-12023-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlert OLX-OP-12025-APO Orbis optical smoke detector with SensAlert and FasTest Intrinsically safe optical smoke detectors with Apollo Approval Reference* 50007 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008-APO adapter base ORB-OP-52027-APO Orbis intrinsically safe optical smoke detector with SensAlert, FasTest and DirtAlert ORB-OP-52028-APO Orbis intrinsically safe optical smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert Bases: 45681-200 Series 60 mounting base 45681-200 Series 60/65 Mounting Base 45681-201 Series 60 diode mounting base 45681-201 Series 60/65 Diode Mounting Base 45681-207 Series 60 intrinsically safe mounting base 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base 45681-215 XP95 intrinsically safe mounting base 45681-245 Series 65 Relay mounting base 45681-246 Series 65 Auxiliary mounting base 45681-247 Series 65 EOL 12 Volt mounting base 45681-248 Series 65 EOL 24 Volt mounting base 45681-500 XPlorer standard mounting base 45681-501 XPlorer remote LED mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** * The Apollo Approval Reference Number identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003 Certificate No: 010m to CEA 4021: 1999-06(en) Certificate No: 010t to EN 54-7: 2000 & CEA 4021: 1999-06 Certificate No: 010ad to EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 LPCB Ref. No. 010q/23 010s/01

Orbis IS

010s/02

12 Sep 2011

161

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Multi-criteria Detectors
Certificated Products XPA-OH-13032-APO Xpander addressable radio linked photoelectric multisensor smoke detector (XPA-WB10022-APO mounting base) Notes: 1) The complete radio base/detector combination is available as Apollo Part No.: XPACB-13032-APO. 2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells. 3) The radio link functionality is not included within the scope of approval. Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base) Note: Certificated at the following settings. Mode 1 - High sensitivity smoke detector with standard heat enhancement. Mode 2 - Smoke detection only. Mode 3 - Medium sensitivity smoke detector with standard heat enhancement. Mode 4 - Low sensitivity smoke detector with high heat enhancement. Mode 5 - Class A1 heat detector. Also Certificated in conventional alarm modes 1, 2, 3, 4 and 5. Certificated with Discovery XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions. Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base)1 Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions. Multisensor smoke detectors with Apollo Approval Reference* 00008 for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base) ORB-OH-13001-APO Orbis multisensor smoke detector with SensAlert, FasTest and DirtAlert ORB-OH-13003-APO Orbis multisensor smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert OAX-OH-13004-APO Orbis multisensor smoke detector with SensAlert OPX-OH-13005-APO Orbis multisensor smoke detector with SensAlert and DirtAlert OEX-OH-13007-APO Orbis multisensor smoke detector with Flashing LED and SensAlert OIX - OH-13008-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlert OMX-OH-13009-APO Orbis multisensor smoke detector with SensAlert and DirtAlert OSX-OH-13011-APO Orbis multisensor smoke detector with Flashing LED and SensAlert OMX-OH-13013-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlert OAX-OH-13014-APO Orbis multisensor smoke detector with Flashing LED and SensAlert OEX-OH-13016-APO Orbis multisensor smoke detector with SensAlert OSX-OH-13017-APO Orbis multisensor smoke detector with SensAlert OPX-OH-13023-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlert OLX-OH-13025-APO Orbis multisensor smoke detector with SensAlert and FasTest Intrinsically safe multisensor detectors with Apollo Approval Reference* 50008 (Approved for use with base styles OB (+ATEX marking) and ORB-MB-50008-APO adapter base) ORB-OH-53027-APO Orbis intrinsically safe multisensor detector with SensAlert, FasTest and DirtAlert ORB-OH-53028-APO Orbis intrinsically safe multisensor detector with Flashing LED, SensAlert, FasTest and DirtAlert Bases: 45681-209 XP95/Discovery standard deep mounting base 45681-210 XP95 mounting base TimeSaver bases with Apollo Approval Reference* OB TimeSaver LX bases with Apollo Approval Reference* OL TimeSaver diode bases with Apollo Approval Reference* OD TimeSaver relay bases with Apollo Approval Reference* OR TimeSaver LX diode bases with Apollo Approval Reference* DX TimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking) ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207) ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201) XPA-WB-10022-APO Radio link mounting base** LPCB Ref. No. 010ad/01

58000-700 Discovery

010h/01

55000-885 XP95

010m/01

Orbis

010t/01

Orbis IS

010t/02

162

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
* The Apollo Approval Reference Number identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS

Certificate No: 010an to EN 54-10: 2002 + A1:2005

Flame Detectors
Certificated Products 55000-022 55000-023 55000-024 55000-025 XP95 intelligentflame detector (45681-209 and 45681-210) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 XP95 intelligent 2 flame detectorand 45681-210) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 XP95 intelligent 3 flame detectorand 45681-210) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 S65 conventional UV flame detector (45681-200 and 45681-201) Note: Meets EN 54-10: 2002 at Class 1 and Class 3 LPCB Ref. No. 010an/01 010an/02 010an/03 010an/04

Bases 45681-200 45681-201 45681-209 45681-210 Mounting Base Mounting Base with Diode Deep Base Mounting Base

Argus Security S.r.l.


Via Josip Ressel 2/7, S Dorligo della Valle, 34018 Trieste, Italy Tel: +39 (0) 402821110 Fax: +39 (0) 402823483 E-mail: dcresseri@argussecurity.it Website: www.argussecurity.it
Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products V350 Analogue addressable Class P heat detector with short circuit isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B Vega-Lite analogue addressable Class P, heat detector (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01

LV350

928d/01

S3500

928d/02

Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S UBR100 DBSR100 UBDR100

Vega adaptor mounting base (with link resistor) Universal adaptor mounting base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode

12 Sep 2011

163

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
DBSRD100 Deep adaptor base with resistor and Schottky diode

Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products V100 Analogue addressable photoelectric smoke detector with short circuit isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Vega-Lite analogue addressable optical smoke detector (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. 1. LPCB Ref. No. 928b/01

LV100

928e/01

S1000

Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100)

928e/02

Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S UBR100 DBSR100 UBDR100 DBSRD100

Vega adaptor mounting base (with link resistor) Universal adaptor mounting base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode

Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003 Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multisensor Detectors
Certificated Products V200 Analogue addressable Class P heat and photoelectric smoke multi sensor detector with short circuit isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. LPCB Ref. No. 928c/01

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) Thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 High Optical only level 2

164

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Optical only level 3 Optical only level 4 Low Vega-Lite analogue addressable photo thermal multisensor (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Notes 1. LPCB Ref. No. 928f/01

LV200

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

Bases VB100 UB100 VB100S UB100S VDBS100 DBS100 VDBS100S DBS100S

Vega adaptor mounting base (with link resistor) Vega universal mounting base Vega adaptor base with shorting clip Universal adaptor base with shorting clip Vega deep adaptor base Deep adaptor base Vega deep adaptor base with shorting clip Deep adaptor base with shorting clip

Certificate No: 928j to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Heat Detectors
Certificated Products SG350 Wireless heat detector (WAB100 base) Notes: 1. 2. LPCB Ref. No. 928j/01

Meets the requirements of EN 54-5 for Class A1R The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases WAB100

Wireless Adaptor Base

Certificate No: 928k to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke Detectors
Certificated Products SG100 Wireless optical smoke detector (WAB100 base) Notes: 1. 2. LPCB Ref. No. 928k/01

Meets the requirements of EN 54-7 in the normal sensitivity setting The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases

12 Sep 2011

165

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
WAB100 Wireless Adaptor Base

Certificate No: 928m to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products SG200 Wireless multi-criteria detector (WAB100 base) Notes: 1. 2. 3. LPCB Ref. No. 928m/01

Meets the requirements of EN 54-5 for Class A1 Meets the requirements of EN 54-7 in the normal sensitivity settings The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases WAB100

Wireless Adaptor Base

Argus-Spectrum Co
65 Serdobolskaya St, St. Petersburg 197342, Russian Federation Tel: +7 812 7037500 Fax: +7 812 7037501 E-mail: mail@argus-spectr.ru Website: www.argus-spectr.ru
Certificate No: 928a-(cl-2) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-2) to EN 54-5: 2000 + A1: 2002 Certificate No: 603d to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products S3500 Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector with short circuit isolator (VB100 and UB100 bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. LV350 Vega-Lite analogue addressable Class P, temperature detector (VB100 and UB100 bases) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B. 928d/01 LPCB Ref. No. 603d/01

V350

928a/01

Bases: BS100 BSD100 VB100 UB100 DBS100 UBR100 DBSR100 UBDR100 DBSRD100

Standard base Schottky Diode base Vega adaptor mounting base (with link resistor) Universal adaptor base Deep adaptor base Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode

Certificate No: 928b-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 603c to EN 54-7: 2000 + A1: 2002 + A2: 2006

166

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Point Smoke Detector
Certificated Products S1000 V100 Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100) Analogue addressable photoelectric smoke detector with short circuit isolator (VB100 and UB100 bases) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Vega-Lite analogue addressable optical smoke detector (VB100 and UB100 bases) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low Bases VB100 UB100 UB100 DBS100 UBR100 DBSR100 UBDR100 DBSRD100 LPCB Ref. No. 603c/01 928b/01

LV100

928e/01

Vega adaptor mounting base (with link resistor) Vega universal mounting base Universal adaptor base Deep adaptor base Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode

Certificate No: 928c-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003 Certificate No: 928f-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-sensor Detectors
Certificated Products V200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (VB100 and UB100 bases) Notes 1. LPCB Ref. No. 928c/01

2. 3.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low 928f/01

LV200

Vega-Lite analogue addressable photo thermal multisensor (VB100 and UB100 bases) Notes 1.

Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 2 - thermally enhanced smoke detection with Class A1 heat response Multi criteria level 3 - thermally enhanced smoke detection with Class A1 heat response

12 Sep 2011

167

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Multi criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No.

2. 3.

Bases VB100 Vega adaptor mounting base (with link resistor) UB100 Vega universal mounting base

ATEIS Middle East FZCO


LIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab Emirates Tel: +971 4 6091325 Fax: +971 4 6091326 E-mail: info@ateis.ae Website: www.ateis.ae
Certificate No: 928a-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 928d-(cl-9) to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products VELOX V350 Analogue addressable Class P heat detector with short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01

VELOX LV350

928d/01

X350

928d/02

Bases VELOX VB100 UB100 VELOX VB100S UB100S VELOX VDBS100 DBS100 VELOX VDBS100S DBS100S UBR100 DBSR100 UBDR100 DBSRD100

Velox adaptor base Universal adaptor base Velox adaptor base with shorting clip Universal adaptor base with shorting clip Velox deep adaptor base Deep adaptor base Velox deep adaptor base with shorting clip Deep adaptor base with shorting clip Universal adaptor base with resistor Deep adaptor base with resistor Universal adaptor base with resistor and Schottky diode Deep adaptor base with resistor and Schottky diode

Certificate No: 928b-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e-(cl-9) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products VELOX V100 Analogue addressable photoelectric smoke detector with short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Note: LPCB Ref. No. 928b/01

168

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Conventional photoelectric smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100 bases) LPCB Ref. No.

VELOX LV100

928e/01

X100

928e/02

Bases VELOX VB100 UB100 VELOX VB100S UB100S VELOX VDBS100 DBS100 VELOX VDBS100S DBS100S

Velox adaptor base Universal adaptor base Velox adaptor base with shorting clip Universal adaptor base with shorting clip Velox deep adaptor base Deep adaptor base Velox deep adaptor base with shorting clip Deep adaptor base with shorting clip

Certificate No: 928c-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Certificate No: 928f-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products VELOX V200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable Class P heat and photoelectric smoke multi-sensor detector (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: LPCB Ref. No. 928c/01

VELOX LV200

928f/01

12 Sep 2011

169

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Bases VELOX VB100 UB100 VELOX VB100S UB100S VELOX VDBS100 DBS100 VELOX VDBS100S DBS100S LPCB Ref. No.

Velox adaptor base Universal adaptor base Velox adaptor base with shorting clip Universal adaptor base with shorting clip Velox deep adaptor base Deep adaptor base Velox deep adaptor base with shorting clip Deep adaptor base with shorting clip

Bardic by Honeywell
140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United Kingdom Tel: +44 (0) 116 246 2212 Fax: +44 (0) 116 246 2210 Website: www.bardic.co.uk
Certificate No: 199n to EN 54-5: 2000

Heat Detectors
Certificated Products ZF03 class A2S ZF04 class BS ZF05 class A1R Conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Conventional rate of rise heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199n/10 199n/11 199n/12

Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode Certificate No: 199m to EN 54-7: 2000

Photoelectric Detectors
Certificated Products ZF01 Conventional photoelectric detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199m/05

Bases: 2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode Certificate No: 199p to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021 1999

Multi-criteria Detectors
Certificated Products ZF02 Conventional photo thermal detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) LPCB Ref. No. 199p/04

Bases:

170

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
2020B Standard base 2020DB Deep base 2020BSD Standard base with schottky diode 2020DBSD Deep base with schottky diode

Beijing Leader Huaxin Electronics Co. Ltd


No. 17 Rongjing Eastern Road, Economy & Technology Developed Area, Beijing 100176, China Tel: +86 10 67876681 Fax: +86 10 67863972 E-mail: hy,chen@beijingleader.com.cn Website: www.beijingleader.com.cn
Certificate No: 987a to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products JTY-GM-LD3000EN/A Analogue addressable photoelectric smoke detector (LD10EN base) LPCB Ref. No. 987a/01

Bases: LD10EN mounting base

Ceasefire Industries Ltd


"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, India Tel: +91 -22-22854677, 22854678 Fax: +91-22-66349069 E-mail: response@ceasefire.in Website: www.ceasefire.in
Certificate No: 117g-(cl-1) to EN54-5:2000

Point Heat Detectors


Certificated Products DFJ-AE3 DCD-CE3 ACB-E Class A1S conventional fixed temperature heat detector (YBN-R/6 base) Class CR conventional rate of rise high temperature heat detector (YBN-R/6 base) Analogue addressable Class P heat detector (YBN-R/3 and YBO-R/SCI bases) Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. LPCB Ref. No. 117g/02 117g/06 117g/09

Bases YBN-R/3 base YBN-R/6 standard base YBO-R/SCI isolator base Certificate No: 358c-(cl-1) to EN54-7:2000

Smoke Detectors
Certificated Products ALK-E (WHT) Analogue addressable optical smoke detector (White) (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Conventional optical smoke detector (White) (YBN-R/6) LPCB Ref. No. 358c/03

SLV-E3 (WHT)

358c/05

Bases YBN-R/3 base YBN-R/6 standard base YBO-R/SCI isolator base YBO-BS base sounder YBO-BSB base sounder and beacon

12 Sep 2011

171

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Chubb Fire Ltd


Chubb House, Staines Road West, Sunbury on Thames TW16 7AR, United Kingdom Tel: +44 (0)1932 785588 Fax: +44 (0)1932 777222 E-mail: sales@chubb.co.uk Website: www.chubb.co.uk
Certificate No: 118h to EN 54-7: 2000

Point Smoke Detectors


Certificated Products Resonance High Sensitivity Laser Analogue addressable photoelectric laser smoke detector (B501, B501DG and B5241EFT & B524IEFT-1 bases) Note: meets the requirements of EN 54-7: 2000 at sensitivities 7 to 9 inclusive LPCB Ref. No. 118h/01

Bases: B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base

Multi-criteria Detectors
Bases: B501Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base

Point Heat Detectors


Bases: B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005

Beam Detectors
Certificated Products Resonance Optical Beam 6500F Analogue optical beam detector with self test facility and short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199w/02

Consilium Marine and Safety AB


Salsmstaregatan 21 Box 8763, Gothenburg SE402 76, Sweden Tel: +46 31 710 77 64 Fax: +46 31 710 78 00 E-mail: cmsab@consilium.se Website: www.consilium.se
Certificate No: 041k-(cl-1) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Photoelectric smoke and heat detectors


Certificated Products EV-PP Analogue addressable combined photoelectric smoke and class A1 heat sensor LPCB Ref. No. 041k/01

172

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases UB-2 Universal base UB-6 Universal base

Context Plus Ltd


Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom Tel: +44 (0)161 257 2541 Fax: +44 (0)161 225 8817 E-mail: xportsales@xportsales.com Website: www.xportsales.com
Certificate No: 010u-(cl-2) to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products 55000-465IMC 55000-475IMC Analogue addressable Class A2S heat detector 45681-213IMC and 45681-505IMC bases) Analogue addressable Class CS heat detector 45681-213IMC and 45681-505IMC bases) LPCB Ref. No. 010u/04 010u/05

Bases 45681-200IMC 45681-213IMC 45681-505IMC

Mounting base Common mounting base Negative switching isolating base

Certificate No: 010v-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products 55000-665IMC Analogue addressable optical smoke 45681-213IMC and 45681-505IMC bases) LPCB Ref. No. 010v/02

Bases 45681-200IMC 45681-213IMC 45681-505IMC

Mounting base Common mounting base Negative switching isolating base

Cooper Industries Inc


Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 303303 Fax: +44 (0)1302 367155 E-mail: sales@cooper-ls.com Website: www.cooper-ls.com UK Sales: Menvier & JSB Tel: +44 (0)1302 303222 Fax: +44 (0)1302 367155 E-mail: enquiries@cooper-ls.com Website: www.cooper.ls.com

UK Sales: Tel: +44 (0)1594 541900 Fax: +44 (0)1594 541910

Certificate No: 685b to EN 54-7: 2000 Certificate No: 685d to EN 54-7: 2000

12 Sep 2011

173

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Point Smoke Detectors
Certificated Products CID310 COP1310 FXN521 MID810 COPP320 CPD320 CPDB320 FXN523 MPD820 CAI310 COP1410 FXN721 MAI810 Conventional ionisation smoke detector (CFS version) (CDB300 base) Conventional ionisation smoke detector (CFS version) (COPC800 base) Conventional ionisation smoke detector (JSB version) (FXN520 base) Conventional ionisation smoke detector (MDB800 base) Conventional photoelectric smoke detector (CFS version) (COPC800 base) Conventional photoelectric smoke detector (CFS version) (CDB300 base) Conventional photoelectric smoke detector (CFS version) (CDBB300 base) Conventional photoelectric smoke detector (JSB version) (FXN520 base) Conventional photoelectric smoke detector (MDB800 base) Analogue addressable ionisation smoke detector (CFS version) (CAB300 base) Analogue addressable ionisation smoke detector (CFS version) (COPA800 base) Analogue addressable ionisation smoke detector (JSB version) (FXN720 base) Analogue addressable ionisation smoke detector (MAB800 base) LPCB Ref. No. 685b/01 685b/01 685b/01 685b/01 685b/02 685b/02 685b/02 685b/02 685b/02 685d/02 685d/02 685d/02 685d/02

Bases: CDB300 standard conventional mounting base (CFS version) CDBB300 standard conventional mounting base (CFS version) COPC800 standard conventional mounting base (CFS version) FXN720 standard analogue addressable mounting base (JSB version) MDB800 standard conventional mounting base MDB800 Standard conventional mounting base (Menvier version) FXN520 Standard conventional mounting base (JSB version)

Point Heat detectors


Bases: FXN720 standard analogue addressable mounting base (JSB version) COPA800 standard analogue addressable mounting base (CFS version) CAB300 standard analogue addressable mounting base (CFS version) CABB300 standard analogue addressable mounting base (CFS Version) MAB800 standard analogue addressable mounting base FXN520 standard conventional mounting base (JSB version) CDB300 standard conventional mounting base (CFS version) CDBB300 standard conventional mounting base (CFS version) COPC800 standard conventional mounting base (CFS version) NDFXN520 standard conventional mounting base (without diode)

Cooper Safety
Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: 01302 321541 Fax: 01302 303220
Certificate No: 685j-(cl-1) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005 Certificate No: 685j-(cl-2) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005 Certificate No: 685h-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 685h-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products CPD321 CPDB321 FXN533 MPD821 CAP320 CAPB320 COPP420 FXN723 MAP820 Conventional photoelectric smoke detector (MDB800/CDB300 base) Conventional photoelectric smoke detector (FXN520/CDBB300 base) Conventional photoelectric smoke detector (FXN520/CDBB300 base) Conventional photoelectric smoke detector (MDB800/CDB300 base) Intelligent analogue addressable photoelectric smoke detector (CAB300 base) Intelligent analogue addressable photoelectric smoke detector (CABB300 base) Intelligent analogue addressable photoelectric smoke detector (COPA800 base) Intelligent analogue addressable photoelectric smoke detector (FXN720 base) Intelligent analogue addressable photoelectric smoke detector (MAB800 base) LPCB Ref. No. 685h/01 685h/01 685h/01 685h/01 685j/01 685j/01 685j/01 685j/01 685j/01

174

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases MAB800 CABB300 FXN720 CAB300 COPA800 MDB800/CDB300 FXN520/CDBB300 Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard conventional mounting base Schottky conventional mounting base

Certificate No: 685k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July 2003(en) Certificate No: 685k-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July 2003(en) Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificate No: 685g-(cl-2) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-criteria Detectors
Certificated Products CPT341 CPTB341 FXN632 MPT951 CAPT340 Conventional photo/thermal multisensor and Class A2S heat detector (MDB800/CDB300 base) Conventional photo/thermal multisensor and Class A2S heat detector (FXN520/CDBB300 base) Conventional photo/thermal multisensor and Class A2S heat detector (FXN520/CDBB300 base) Conventional photo/thermal multisensor and Class A2S heat detector (MDB800/CDB300 base) Intelligent analogue addressable Class A2S multisensor opto/heat detector (CAB300 base) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) Intelligent analogue addressable Class A2S multisensor opto/heat detector (CABB300 base) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) Intelligent analogue addressable Class A2S multisensor opto/heat detector (COPA800 base) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) Intelligent analogue addressable Class A2S multisensor opto/heat detector (FXN720 base) Notes: 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) Intelligent analogue addressable Class A2S multisensor opto/heat detector (MAB800 base) Notes: LPCB Ref. No. 685g/01 685g/01 685g/01 685g/01 685k/01

CAPTB340

685k/01

COPOH450

685k/01

FXN722

685k/01

MAOH850

685k/01

12 Sep 2011

175

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) LPCB Ref. No.

Bases MAB800 CABB300 FXN720 CAB300 COPA800 MDB800/CDB300 FXN520/CDBB300 Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard conventional mounting base Schottky conventional mounting base

Certificate No: 685m-(cl-1) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005 Certificate No: 685m-(cl-2) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005

Heat Detectors
Certificated Products CAH330 Intelligent analogue addressable Class P heat detector (CAB300 base) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector (CABB300 base) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector (COPA800 base) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector (FXN720 base) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS Intelligent analogue addressable Class P heat detector (MAB800 base) Notes: 1) Meets the requirements of EN 54-5 at classes A1R, BS and CS LPCB Ref. No. 685m/01

CAHB330

685m/01

COPH430

685m/01

FXN725

685m/01

MAH830

685m/01

Bases MAB800 CABB300 FXN720 CAB300 COPA800 Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base Standard analogue addressable mounting base

Certificate No: 685a-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 685a-(cl-2) to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products CFR330 CFRB330 FXN525 MFR830 CMT360 CMTB360 Conventional Class A2S heat detector base) Conventional Class A2S heat detector (FXN520/CDBB300 base) Conventional Class A2S heat detector base) Conventional Class A2S heat detector base) Conventional Class BS heat detector base) Conventional Class BS heat detector base) LPCB Ref. No. 685a/01 685a/01 685a/01 685a/01 685a/02 685a/02

176

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products FXN524 MMT860 CHT390 CHTB390 FXN526 MHT890 Conventional Class BS heat detector base) Conventional Class BS heat detector base) Conventional Class CS heat detector base) Conventional Class CS heat detector base) Conventional Class CS heat detector base) Conventional Class CS heat detector base) LPCB Ref. No. 685a/02 685a/02 685a/03 685a/03 685a/03 685a/03

Bases MDB800/CDB300 Standard conventional mounting base FXN520/CDBB300 Schottky conventional mounting base

Cooper Scurit SAS


Parc Europen dEntreprises II, Rue Beethoven, BP 10184, 63204 Riom Cedex, France Tel: +44 (0)1302 3397 Fax: +44 (0)1302 303220 E-mail: Fariz.khellaf@cooperindustries.com
Certificate No: 685j-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 685h-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products DOFS3000 DOFA3000 Conventional photoelectric smoke detector (NUG30255 base) Intelligent analogue addressable photoelectric smoke detector (NUG30256 base) LPCB Ref. No. 685h/01 685j/01

Bases NUG30256 NUG30255 Standard analogue addressable mounting base Standard conventional mounting base

Certificate No: 685m-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005

Heat Detectors
Certificated Products DTVA3000 Intelligent analogue addressable Class P heat detector (NUG30256 base) Notes: 1. Meets the requirements of EN 54-5 at classes A1R, BS and CS LPCB Ref. No. 685m/01

Bases NUG30256 Standard analogue addressable mounting base

Certificate No: 685k-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 , EN 54-17: 2005 and CEA4021: July 2003(en) Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products DMCFS3000 DMCFA3000 Conventional photo/thermal multisensor and Class A2S heat detector (NUG30255 base) Intelligent analogue addressable Class A2S multisensor opto/heat detector (NUG30256 base) Notes: 1. Meets the requirements of EN 54-5 and EN 54-7in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S) LPCB Ref. No. 685g/01 685k/01

12 Sep 2011

177

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases NUG30255 NUG30256 Standard conventional mounting base Standard analogue addressable mounting base

Certificate No: 685a-(cl-3) to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products DTVS3000 DTS77S3000 DTS90S3000 Bases NUG30255 Conventional Class A2S heat detector (NUG30255 base) Conventional Class BS heat detector (NUG30255 base) Conventional Class CS heat detector (NUG30255 base) LPCB Ref. No. 685a/01 685a/02 685a/03

Standard conventional mounting base

Detector Electronics Corporation


Minneapolis, Minesota 55438, United States Tel: +001 952 946 6488 E-mail: detronics@detronics.com Website: www.det-tronics.com
Certificate No: 973a to EN 54-10: 2002 + A1: 2005 and EN 54-17: 2005 Certificate No: 973e to EN 54-10: 2002 + A1: 2005 Certificated Products X9800 Addressable Class 1 IR flame detector with short circuit isolator Note : The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Addressable Class 1 UV / IR flame detector with short circuit isolator Note : The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Addressable Class 1 multispectrum IR flame detector with short circuit isolator Note: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Addressable Class 1 UV flame detector with short circuit isolator The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Conventional Class 1 IR flame detector Conventional Class 1 UV / IR flame detector Conventional Class 1 multispectrum IR flame detector Conventional Class 1 UV flame detector LPCB Ref. No. 973a/01

X5200

973a/02

X3301

973a/03

X2200

973a/04

X9800 X5200 X3301 X2200

973e/01 973e/02 973e/03 973e/04

EMCO
125 El Alamean Street, El Mohandessin, Cairo, Egypt Tel: 00202 33 44 3 245 Fax: 00202 330 36 86 0 E-mail: emco@4emco.com Website: www.4emco.com
Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 928d to EN 54-5: 2000 + A1: 2002

178

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products AD203S Analogue addressable Class P heat detector with short circuit isolator (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector lite (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01

AD203

928d/01

Bases AB100 AB100D AB200 AB200D AB100-S AB100D-S AB200-S AB200D-S

Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip

Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products AD201S Analogue addressable photoelectric smoke detector with short circuit isolator (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector lite (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928b/01

AD201

928e/01

Bases AB100 AB100D AB200 AB200D AB100-S AB100D-S AB200-S AB200D-S

Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip

Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003 Certificated Products AD202S Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke LPCB Ref. No. 928c/01

12 Sep 2011

179

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low 928f/01 LPCB Ref. No.

2. 3.

AD202

Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

Bases AB100 AB100D AB200 AB200D AB100-S AB100D-S AB200-S AB200D-S

Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip

Emergi-Lite Safety Systems (Thomas & Betts Ltd)


Bruntcliffe Lane, Morley, Leeds LS27 9LL, United Kingdom Tel: +44 (0)113 2810600 Fax: +44 (0)113 2810601 Website: www.emergi-lite.co.uk
Certificate No: 010p to EN 54-5:2000 + A1:2002

Point Heat Detectors


Certificated Products FADY-TEM Analogue addressable heat detector (FA95-ACB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 Class A1R in mode 1 and in conventional mode Class A2 in mode 2 and in conventional mode Class A2S in mode 3 and in conventional mode Class CR in mode 4 and in conventional mode Class CS in mode 5 and in conventional mode LPCB Ref. No. 010p/03

180

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. Conventional Class A1R heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class A1R Conventional Class BR heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class BR Conventional Class CR heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class CR Conventional Class CS heat detector (FAP6-STB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 - Class CS LPCB Ref. No. 010p/06 010p/09 010p/12 010p/15

FAP6-RR6 FAP6-RR75 FAP6-RR90 FAP6-FT8

Bases: FAP6-STB Mounting base Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002, CEA 4021:2003

Multi-criteria Detectors
Certificated Products FADY-MUS Analogue addressable multisensor detector (FA95-ACB mounting base) Notes: 1) Certificated at the following settings: Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. LPCB Ref. No. 010h/01

Bases: FA95-ACB Mounting base FAP6-STB Diode mounting base Certificate No: 010q to EN 54 - 7:2000 + A1:2002

Point Smoke Detectors


Certificated Products FADY-OPT Analogue addressable optical smoke detector (FA95-ACB mounting base) Notes: 1) Meets the requirements of EN54: Part 7 in modes 1, 2, 3, 4 and 5 and in conventional mode. 2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions. Conventional ionisation smoke detector (FAP6-STB mounting base) Conventional optical smoke detector (FAP6-STB mounting base) LPCB Ref. No. 010q/03

FAP6-ION FAP6-OPT Bases; FAP6-STB Mounting base

010q/06 010q/12

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)


P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates Tel: +971 6 5340300 Fax: +971 6 5340090 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 506a to EN54-7: 2000

12 Sep 2011

181

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Point Smoke Detectors
Certificated Products FX-0311-2 FX-0311-3 FX-0311-4 Bases: AHMB-031 mounting base Certificate No: 506b to EN43-7: 2000 & CEA 4021: 1999 (2 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) (3 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) (4 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) LPCB Ref. No. 506a/02 506a/03 506a/04

Multi-criteria Detectors
Certificated Products FX-0315-2 FX-0315-3 FX-0315-4 Bases: AHMB-031 mounting base Certificate No: 506c to EN54-5: 2000 (2 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) (3 - wire) Optical smoke and Class A2 detector (AHMB-31 Base) (4 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) LPCB Ref. No. 506b/01 506b/02 506b/03

Point Heat Detector


Certificated Products FX-0316-2 FX-0316-3 FX-0316-4 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB31 Base) (3 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 Base) (4 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB31 Base) LPCB Ref. No. 506c/01 506c/02 506c/03

Bases: AHMB-031 mounting base

Eurotech Fire Systems Ltd


19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United Kingdom Tel: (0)203 141 0999 E-mail: enquiry@eurotechfire.com Website: www.eurotechfire.com
Certificate No: 041f-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 842a-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products EURV-P EURVC-P EURVC-P EURV-P Analogue addressable optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. Conventional optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Conventional optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Analogue addressable optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. LPCB Ref. No. 041f/01 041f/03 842a/01 842a/04

Bases EURB-4 universal mounting base EURB-4-EV universal mounting base EURB-4SD universal mounting base with schottky diode EURB-4SE-EV Standard deep base

182

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Certificate No: 041g-(cl-1) to EN 54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 1999 Certificate No: 041h-(cl-1) to EN54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products EURV-PH EURV-H-A1R EURV-H-CS EURVC-H-A2S EURVC-H-CS Analogue addressable optical smoke / class A1R heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings. Analogue addressable Class A1R heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Analogue addressable Class CS heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Conventional Class A2S heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Conventional Class CS heat detector (EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) LPCB Ref. No. 041g/01 041h/01 041h/02 041h/03 041h/04

Bases EURB-4 universal mounting base EURB-4-EV universal mounting base EURB-4SD universal mounting base with schottky diode EURB-4SE-EV Standard deep base

Everday Technology Co. Limited


No,.95., Sec. 2., Ligong 1 St. Road., Letzer Industrial Park, Yilan County 26841, Taiwan ROC Tel: +886 3 990 6099 Fax: +862 3 990 6029 E-mail: sales@everday.com Website: sales.everday@everday.com
Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products EA318-2 EA318-2(LED) EA318-4-12 EA318-4-24 Conventional 2 wire photoelectric smoke detector (P/N852001 base) Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) Conventional 4 wire photoelectric smoke detector (P/N854001 base) LPCB Ref. No. 512a/01 512a/02 512a/03 512a/04

Bases: P/N854001 4-wire detector base P/N852001 2-wire detector base

Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003

Multi-criteria Detectors
Certificated Products EA318-2H EA318-2H-LED EA318-4H-12 EA318-4H-24 Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) LPCB Ref. No. 512b/01 512b/02 512b/03 512b/04

12 Sep 2011

183

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases: P/N854001 4-wire detector base P/N852001 2-wire detector base

Certificate No: 512d to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products EA323-2 EA323-2 EA323-2L EA323-2L EA323-4 EA323-4 EA323-4 EA323-4 Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base) Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base) LPCB Ref. No. 512d/01 512d/02 512d/03 512d/04 512d/05 512d/06 512d/07 512d/08

Bases: P/N852001 2-Wire detector base P/N854001 4-Wire detector base

Fire Fighting Enterprises Ltd


9 Hunting Gate, Hitchin, Hertfordshire SG4 0TJ, United Kingdom Tel: +44 (0) 1462 444740 Fax: +44 (0) 1462 444789 E-mail: sales@ffeuk.com Website: www.ffeuk.com
Certificate No: 831a to EN 54-12: 2002 Certificated Products Fireray 5000 Multi-head Conventional self aligning optical beam detector and system controller (0020-017 mounting bracket) Notes: 1. Meets the requirements of EN 54-12 :2002 when configured with the following settings: Delay to fire setting between 2 and 20 seconds only Sensitivity level setting from 25% to 35% only 2. The device is available as 50m (approved over a range of 8 to 50m) and 100m (approved over a range of 50 to 100m) versions. 3. Approved for use with 1-4 detector heads. LPCB Ref. No. 831a/01

Fireguard Safety Equipment Co Ltd


2nd Floor, 145-147 St John Street, London EC1V 4PY, United Kingdom Tel: +44 (0)8450 751042 Fax: +44 (0)8450 751043 E-mail: info@fireguard-uk.com Website: www.fireguard-uk.com
Certificate No: 512a-(cl-4) to EN 54-7: 2000 + A1: 2002 Certificate No: 928e-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products Fireguard FG318-2L Conventional 2 wire photoelectric smoke detector with remove LED output (Fireguard LPCB Ref. No. 512a/02

184

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products P/N FG854001 base) Bases: Fireguard P/N FG854001 4 wire detector base Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No.

FGSD100

928e/01

Bases VB100 Vega adaptor base (with link resistor) UB100 Universal adaptor base VB100S Vega adaptor base with shorting clip UB100S Universal adaptor base with shorting clip VDBS100Vega deep adaptor base DBS100 Deep adaptor base VDBS100S Vega deep adaptor base with shorting clip DBS100SDeep adaptor base with shorting clip Certificate No: 512d-(cl-4) to EN54-5: 2000 + A1: 2002 Certificate No: 928d-(cl-7) to EN 54-5: 2000 + A1: 2002 Certificated Products Fireguard FG323-2L Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (Fireguard P/N FG854001 base) Bases: Fireguard P/N FG854001 4 wire detector base Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 512d/04

FGHD350

928d/01

Bases VB100 Vega adaptor base (with link resistor) UB100 Universal adaptor base VB100S Vega adaptor base with shorting clip UB100S Universal adaptor base with shorting clip VDBS100Vega deep adaptor base DBS100 Deep adaptor base VDBS100S Vega deep adaptor base with shorting clip DBS100SDeep adaptor base with shorting clip

Fireonica Co. Ltd


2 The Dingle, Wolverhampton WV3 9ET, United Kingdom Tel: 01902 762 163 Fax: 0845 075 1043 E-mail: info@fireguard-uk.com
Certificate No: 928d-(cl-8) to EN 54-5: 2000 + A1: 2002 Certificate No: 928e-(cl-8) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products FOHD350 Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928d/01

12 Sep 2011

185

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products FOSD100 Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928e/01

Bases VB100 Vega adaptor base (with link resistor) UB100 Universal adaptor base VB100S Vega adaptor base with shorting clip UB100S Universal adaptor base with shorting clip VDBS100Vega deep adaptor base DBS100 Deep adaptor base VDBS100S Vega deep adaptor base with shorting clip DBS100SDeep adaptor base with shorting clip

FIREX Protection System Technology Ltd


28-38 Desborough Street, High Wycombe, Bucks, United Kingdom Tel: +44 (0)1494 601077 Fax: +44 (0)1494 601011 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 548c to EN 54-5: 2000

Heat Detectors
Certificated Products FX9103 FX9103I Conventional heat detector Class A1R (DZ-03 base) Intelligent Rate of Rise Heat Detector Class A1R (DZ-03 base) LPCB Ref. No. 548c/01 548c/02

Bases: DZ-03 Standard detector base Certificate No: 548d to EN 54-7: 2000

Smoke Detectors
Certificated Products FX9102 FX9102I Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02

Bases: DZ-03 Standard detector base Certificate No: 548k to EN 54-12:2002

Beam Detectors
Certificated Products FX9105RI Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01

186

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

GE Security Inc (Trading As Edwards System Technology)


8985 Town Center Parkway, Bradenton, Florida, United States Tel: 941 739-42228 E-mail: gesecurity.customerservice@ge.com
Certificate No: 262s to EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 1999

Multi-Criteria Detectors
Certificated Products SIGA-IPHSI Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 & SIGA-AB4G bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2) The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases Intelligent analogue addressable thermally enhanced photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2) The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases LPCB Ref. No. 262s/01

SIGA-PHSI

262s/02

Bases: SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base SIGA-RB4 Relay base with trim skirt SIGA-IB Isolator Base SIGA-IB4 Isolator base with 4 inch mounting adaptors SIGA-AB4G Sounder base Accessories SIGA-LED Indicator

Certificate No: 262t to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products SIGA-ISI Intelligent analogue addressable ionisation smoke detector SIGA-SB, SIGA-SB4, SIGARB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2) The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases Intelligent analogue addressable photoelectric smoke detector SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2) The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases LPCB Ref. No. 262t/01

SIGA-PSI

262t/02

12 Sep 2011

187

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases: SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base SIGA-RB4 Relay base with trim skirt SIGA-IB Isolator Base SIGA-IB4 Isolator base with 4 inch mounting adaptors SIGA-AB4G Sounder base Accessories SIGA-LED Indicator

Certificate No: 262u to EN 54-5:2000 + A1:2002

Point Heat Detectors


Certificated Products SIGA-HRSI Intelligent analogue addressable Class A1 & A2R rate of rise heat detector SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 and SIGA-AB4G bases) Notes: 1) The SIGA-LED indicator is also approved for use with the SIGA-SB and SIGA-SB4 bases LPCB Ref. No. 262u/02

Bases: SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base SIGA-RB4 Relay base with trim skirt SIGA-IB Isolator Base SIGA-IB4 Isolator base with 4 inch mounting adaptors SIGA-AB4G Sounder base Accessories SIGA-LED Indicator

Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries: E-mail: gent.export@honeywell.com

Certificate No: 567a to BS 5445: Part 7: 1984 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Certificate No: 042bd to EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005 Certificate No: 042az to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products 17840-01 Conventional optical smoke detector (17800-01, 17800-02, 17801-01, 17801-02 mounting bases) LPCB Ref. No. 042az/01

188

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products S4-715 S-Quad analogue addressable optical smoke detector Standard base with or without S4FLUSH semi-flush fixing kit) Note: 1) Meets the requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical Conventional photoelectric smoke detector (17800-01, 17801-01, 17800-02 and 1780102 bases) Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. LPCB Ref. No. 042bd/01

17840-01

567a/02

Bases: 78200-01NM standard base 17800-01 standard base 17801-01 standard base with diode 17800-02 low profile base 17801-02 low profile base with diode S4-700 Standard base S4-FLUSH Semi-flush fixing kit Certificate No: 567b to BS 5445: Part 5: 1977 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. Certificate No: 042ak to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 & CEA GEI 1 - 084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0 Certificate No: 042be to EN54-5: 2000+A1: 2002, EN54-17: 2005, EN54-18: 2005 Certificate No: 042ay to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products S4-780 S-Quad analogue addressable Class P heat detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirements of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable Class P heat detector with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Conventional Class A1 fixed temperature heat detector (17800-01, 17800-02, 17801-01, 17801-02 mounting bases) Conventional Class A1 rate of rise heat detector (17800-01, 17800-02, 17801-01, 1780102 mounting bases) S-Quad analogue addressable Class P heat detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) LPCB Ref. No. 042ak/01

S4-780-ST 17850-01 17860-01 S4-720

042ak/03 042ay/01 042ay/02 042be/01

Note: Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B

17850-01

Conventional grade 1 fixed temperature heat detector (17800-01, 17801-01, 17800-02 and 17801-02 bases)

567b/01

12 Sep 2011

189

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 17860 -01 Conventional grade 1 rate-of-rise heat detector (17800-01, 17801-01, 17800-02 and 17801-02 bases) Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU. 567b/02 LPCB Ref. No.

Bases: 17800-01 standard base 17801-01 standard base with diode 17800-02 low profile base 17801-02 low profile base with diode S4-700 standard base S4-FLUSH semi-flush fixing kit Certificate No: 042am to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003-07 & CEA GEI 1 - 084 and CEA GE 1 - 052: 11.06.97 Draft 2.0 Certificate No: 042an to EN 54-5: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1:2002, CEA 4021: 2003-07, CEA GEI 1 - 084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0 Certificate No: 042bf to EN54-5: 2000+A1: 2002, EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005

Multi-criteria Detectors
Certificated Products S4-711-ST S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) The strobe function is not included within the scope of this approval S-Quad analogue addressable dual optical smoke, Class P heat and carbon monoxide multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 5 at the following settings: State 9 - Class A1 heat 3) Carbon monoxide detection is not included within the scope of this approval S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Speech and strobe not included in scope of approval S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) LPCB Ref. No. 042am/02

S4-911

042am/03

S4-711-ST-VO

042an/01

S4-771

042an/02

190

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S4-911-ST-VO S-Quad analogue addressable optical smoke, heat and carbon monoxide multisensor detector with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirements of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 5 at the following settings: State 9 - Class A1 heat 3) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 4) Carbon monoxide detection, speech and strobe not included within the scope of this approval S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Speech not included in scope of approval. S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Strobe not included in scope of approval. S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit) Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat S4-711 S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush fixing kit) Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat 042bf/02 042an/03 LPCB Ref. No.

S4-711-VO

042an/05

S4-770-ST

042an/06

S4-710

042bf/01

Bases:

12 Sep 2011

191

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
34700 standard base S4-700 standard base S4-FLUSH semi-flush fixing kit Certificate No: 042bh to EN 54-12: 2002 and EN 54-17: 2005

Beam Detectors
Certificated Products S4-34740 Analogue addressable optical beam smoke detector with short circuit isolator ( S4-34741-01 and S4-34741-03) Notes: 1. The S4-34740 beam sensor pair comprises of an S4-34741 beam transmitter, plus an S4-34742 beam receiver. 2. Meets the requirements of EN 54-12 at the following sensitivity settings: States 0, 1: 3.01dB States 2, 3: 1.25dB LPCB Ref. No. 042bh/01

Ancillaries: S4-34741-01 beam angle bracket S4-34741-03 beam parallel bracket

GEZE GmbH
Reinhold-Vster-Str. 21-29, D-71229 Leonberg, Germany Tel: +49 (0)7152-203-0 Fax: +49 (0)7152-203-310 E-mail: p.igl@geze.com Website: www.geze.com
Certificate No: 928d-(cl-10) to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products GC003 D Conventional non-latching Class P heat detector (GC160 B base) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928d/02

Base GC160 B

Universal adaptor base

Certificate No: 928e-(cl-10) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products GC002 D Base GC160 B Conventional non-latching photo smoke detector (GC160 B base) LPCB Ref. No. 928e/02

Universal adaptor base

Global System Technology Plc


Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United Kingdom Tel: +44 (0)1283 225 478 Fax: +44 (0)1283 222 039 E-mail: info@gst.uk.com Website: www.gst.uk.com
Certificate No: 548k to EN 54-12:2002

192

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Beam Detectors
Certificated Products I-9105R Intelligent Reflective Beam Detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31 dB LPCB Ref. No. 548k/01

Certificate No: 548c to EN 54-5:2000

Point Heat Detectors


Certificated Products C9103 I-9103 Bases: DZ-03 Standard detector base Certificate No: 548d to EN 54-7:2000 Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R heat detector (DZ-03 base) LPCB Ref. No. 548c/01 548c/02

Smoke Detectors
Certificated Products C-9102 I-9102 Bases: DZ-03 Standard detector base Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02

Group 4 Securicor Plc


Manor Royal, The Manor, Crawley, West Sussex RH10 9UN, United Kingdom Tel: +44 (0)20 87707000 Fax: +44 (0)20 87722531 Website: www.g4s.com
Certificate No: 548c to EN 54-5: 2000

Heat Detectors
Certificated Products GS104C GS104I Conventional heat detector Class A1R (DZ-03 base) Intelligent rate of rise heat detector Class A1R (DZ-03 base) LPCB Ref. No. 548c/01 548c/02

Bases DZ-03 Standard detector base Certificate No: 548d to EN54-7: 2000

Smoke Detectors
Certificated Products GS102C GS102I Conventional photoelectric smoke detector (DZ-03 base) Intelligent photoelectric smoke detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02

Bases DZ-03 Standard detector base

12 Sep 2011

193

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 548k to EN 54-12:2002

Beam Detectors
Certificated Products GS105RI Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01

Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn Sales Enquiries: Tel: +852 28778566 Fax: +852 25118699 Tel: +86 (10)64392919 Fax: +86 (10)64391767

Certificate No: 548c to EN 54-5: 2000

Point Heat Detectors


Certificated Products JTWB-ZCD-G1 (A) JTW-ZCD-G3N Bases: DZ-03 Standard detector base Certificate No: 548d to EN 54-7: 2000 Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R Rate of Rise Heat Detector (DZ-03 base) LPCB Ref. No. 548c/01 548c/02

Point Smoke Detector


Certificated Products JTY-GF-GST104 JTY-GD-G3 Bases: DZ-03 standard detector base Certificate No: 548k to EN 54-12:2002 Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02

Beam Detectors
Certificated Products JTY-HM-GST102 Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31 dB LPCB Ref. No. 548k/01

194

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 117f to EN54-7: 2000 + A1: 2002, EN54-5: 2000 + A1: 2002 and CEA 4021: 1999

Multi-Criteria Detectors
Certificated Products 1410010 Intelligent analogue addressable multisensor (YBN-R/3 base) Note: Meets EN 54-5 class A1 and B and EN 54-7 at 3.0%/m sensitivity setting in normal and low power mode. LPCB Ref. No. 117f/01

Certificate No: 117g to EN 54 Part 5: 2000

Point Heat Detectors/Sensors


Certificated Products 1215110 1215120 1217180 1217190 1410020 Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and 1226150) Class CS conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and 1226150 bases) Class A1R conventional rate of rise temperature heat detector (YCA-RL/3H2M, YBNR/6SK and 1226150 bases) Conventional Class CR rate of rise high temperature heat detector (YBN-R/6SK and 1226150 bases) Intelligent analogue addressable Class P heat detector (1426010 and 1226110 bases) Note: Meets requirements of EN54-5: 2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. LPCB Ref. No. 117g/02 117g/03 117g/04 117g/06 117g/09

Bases: 1226150 Standard base 1426010 Standard base YCA-RL/3H2M Addressable base YBN-R/6SK Schottky diode base Certificate No: 117j to EN 54-12: 2002

Beam Detectors
Certificated Products 1213060 1213080 Optical Beam Smoke Detector Note: Certified at a sensitivity setting of 30% obscuration Conventional 2 wire optical beam smoke detector Notes: 1) Approved at sensitivity setting 25% and 50%. 2) Approved for use with 1213080 2WI interface kit. LPCB Ref. No. 117j/01 117j/03

Certificate No: 164g to EN 54-7: 2000 + A1: 2002

Point Smoke Detectors


Bases: 1226110 Short circuit isolating base 1226150 Standard base 1426010 Standard base YBN-R/6SK Schottky Diode base

12 Sep 2011

195

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 358c to EN 54-7: 2000

Point Smoke Detectors/Sensors


Certificated Products 1412110 Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) LPCB Ref. No. 358c/03

1412120

358c/04

1212270 1212280

358c/05 358c/06

Bases YBN-R/3 YBO-R/SCI YBO-BS YBO-BSB YBN-R/6 YBN-R/6SK YBO-R/6R YBO-R/6RS YBO-R/6RN YBO-R/6PA Standard base Positive switching short circuit isolator base Sounder base Sounder base with Beacon Standard base Standard base with schottky diode Relay base Relay base latching with schottky diode Relay base non latching Protector alarms base

Hochiki America Corporation


7051 Village Drive, Buena Park, California 90621, United States Tel: +1 714 522 2246 Fax: +1 714 522 2268 E-mail: sales@hochiki.com Website: www.hochiki.com
Certificate No: 358d to EN 54-10: 2002 + A1: 2005

Flame Detectors
Certificated Products IR3 IR3-IS IR3-EX IR2-UV IR2-UV-EX Conventional IR 3 Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 Intrinsically Safe Flame Detector Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 (Exd) Flameproof Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR 2 (Exd) Flameproof Flame Detector (IR-AMB) Note: Meets EN 54-10: 2002 at Class 1 only LPCB Ref. No. 358d/01 358d/02 358d/03 358d/04 358d/05

Ancillaries IR-AMB Mounting Bracket

196

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Hochiki Corporation
246 Tsuruma, Machidia, Tokyo 194-8577, Japan Tel: +81 3 3444 4111 Fax: +81 3 3444 4167 E-mail: info@hochiki.co.jp Website: www.hochiki.co.jp
Certificate No: 117k to EN 54-10: 2002 + A1: 2005 Certificated Products DRD-E Conventional Class 1 IR Flame Detector (YBN-R/6SK, YBN-R/6, YBO-R/6R, YBO-R/6RN, YBO-R/6PA, YBO-R/6RS) LPCB Ref. No. 117k/01

Bases YBN-R/6SK YBN-R/6 YBO-R/6R YBO-R/6RN YBO-R/6PA YBO-R/6RS Conventional Schottky diode base Conventional standard base Conventional latching relay base Conventional non-latching relay base Conventional 2 wire base Conventional latching relay base with integral Schottky diode

Hochiki Europe (UK) Limited


Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 Website: www.hochikieurope.com All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260131 Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 Fax: +81 3 3444 4167 E-mail: overseas@hochiki.co.jp Website: www.hochiki.co.jp

Manufacturing at (Certificate Nos. 164, 164g, 164m) Hochiki Europe (UK) Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (01634 260131 Fax: +44 (0)1634 260132 E-mail: sales@hochikieurope.com Website: www.hochikieurope.com

Manufacturing at (Certificate Nos. 358, 358c) Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, United States Tel: +1 714 522 2246 Fax: +1 714 522 2268 E-mail: overseas@hochiki.co.jp Website: www.hochiki.com

Certificate No: 117g to EN 54 Part 5: 2000

12 Sep 2011

197

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Point Heat Detectors/Sensors
Certificated Products DCD-1E-IS DFJ-AE3 DFJ-AE3 (HFP) DFJ-CE3 DFJ-CE3 (HFP) DCD-AE3 DCD-AE3 (HFP) DCD-AE3M DFG-60BLKJ DCD-CE3 DCD-CE3(HFP) DCD-CE3M ACB-E Class A1 conventional intrinsically safe fixed temperature and rate of rise heat detector (YBN-R/4IS1 base) Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and YBN-R/6 bases) Class A1S conventional fixed temperature heat detector (YBN-R/6(HFP) base) Class CS conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK Schottky and YBN-R/6 bases) Class CS conventional fixed temperature heat detector (YBN-R/6(HFP)base) Class A1R conventional rate of rise temperature heat detector (YCA-RL/3H2M, YBNR/6SK and YBN-R/6 bases) Class A1R conventional rate of rise temperature heat detector (YBN-R/6 (HFP)base) Conventional Class A1R rate of rise temperature heat detector (YBN-R/6M base) Class A2 conventional fixed temperature water resistant heat detector CDX Class CR conventional rate of rise high temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and YBN-R/61 bases) Class CR conventional rate of rise high temperature heat detector (YBN-R/6(HFP)base) Conventional Class CR rate of rise high temperature heat detector (YBN-R/6M base) Intelligent Analogue addressable Class P heat detector (YBN-R/3 and YBO-R/SCI1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Intelligent analogue addressable Class P heat detector (YBN-R/3(HFP) and YBOR/SCI(HFP) bases). Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Intelligent analogue addressable Class P heat detector (YBN-R/3 and YBO-R/SCI bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Weather proof Intelligent Analogue addressable Class P heat detector (YBN-R/31 and YBO-R/SCI1 bases) Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol. Conventional Intrinsically Safe Mounting base Addressable base Schottky diode base Standard base Standard base Positive Switching Short circuit isolating base Standard Base LPCB Ref. No. 117g/01 117g/02 117g/02 117g/03 117g/03 117g/04 117g/04 117g/04 117g/05 117g/06 117g/06 117g/06 117g/09

ACB-E (HFP)

117g/09

ACB-EM

117g/09

ACB-EW

117g/10

YBN-R/4IS YCA-RL/3H2M YBN-R6 SK YBN-R/6 YBN-R/3 YBO-R/SCI YBN-R/6M

All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260131 Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 Fax: +81 3 3444 4167

Certificate No: 117j to EN 54-12: 2002

Beam Detectors
Certificated Products SRA-ET SRA-ET (HFP) Optical Beam Smoke Detector Note: 1) Certified at sensitivity settings 30% obscuration Optical Beam Smoke Detector LPCB Ref. No. 117j/01 117j/01

198

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: 1) Certified at sensitivity settings 30% obscuration Conventional 4 wire optical beam smoke detector Notes: 1) Approved at sensitivity setting 25% and 50% Conventional 2 wire optical beam smoke detector Notes: 1) Approved at sensitivity setting 25% and 50% 2) Approved for use with SPC-ET2WI interface kit Conventional 2 wire optical bem smoke detector. Notes: 1) Approved at sensitivity setting 25% and 50% 2) Approved for use with SPC-ET2WI interface kit LPCB Ref. No. 117j/02 117j/03

SPC-E SPC-ET

SPC-ET(HFP)

117j/03

All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260131 Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 Fax: +81 3 3444 4167

Certificate No: 117f to EN 54: 2000 + A1: 2002, EN 54-4: 2000 + A1: 2002 and CEA 4021: 1999

Multi-criteria Detectors
Certificated Products ACA-E ACA-E (HFP) Intelligent Analogue addressable multisensor (YBN-R/3 base) Note: Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode. Intelligent analogue addressable multisensor (YBN-R/3(HFP) base) Note: Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode. LPCB Ref. No. 117f/01 117f/01

Bases: YBN-R/3 base YBN-R/3 Standard base YBN-R/2NA base YBO-R/SCI Positive switching short circuit isolator base YBN-R/4IS intrinsically safe mounting base1 YCA-RL/3H2 addressable base YCA-RL/5H2 master addressable base AMU-B2 addressable base AMU-MB master addressable base YBC-RL/4H5 base YBF-RL/3J slave base YBF-RL/4H5 base1 YBK-RL/4H1A base1 YBK-RL/4H2 base1 YCA-RL/3H2M addressable base YBN-R/6SK Schottky diode base YBN-R/6 Standard base YBN-R/4 base1 YBN-R/6M Standard base YBO-BS Sounder base YBO-BSB Sounder base with Beacon YBO-R/5 base1 YBN-R/4M base1 YBO-R/5M base1 YBO-R/6R Relay base YBO-R/6RS Relay base latching with schottky diode YBO-R/6RN Relay base non latching YBO-R/6PA Protector alarms base

12 Sep 2011

199

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
YBO-RSCI/NS Negative Switching Short circuit isolating base YBF-RL/4H3H 2 wire mounting base YBF-RL/4H5H 2 wire mounting base
1 LP

Bases manufactured buy Hochiki Europe. All other bases manufactured by Hochiki Corporation. denotes detector/base combination is approved in low power mode also.

All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 Fax: +44 (0) 1634 260132

Manufacturing at (Certificate Nos 117, 117f, 117g, 117h, 117j) Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, Japan Tel: +81 3 3444 4111 Fax: +81 3 3444 4167 E-mail: overseas@hochiki.co.jp Website: www.hochiki.co.jp

Manufacturing at (Certificate Nos 164, 164g, 164m) Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 Fax: +44 (0) 1634 260132 E-mail: sales @hochikieurope.com Website: www.hochikieurope.com

Manufacturing at (Certificate Nos 358, 358c) Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, United States Tel: +1 714 522 2246 Fax: +1 714 522 2268 E-mail: overseas@hochiki.co.jp Website: www.hochiki.com

Certificate No: 117h to EN 54-7: 2000 Certificate No: 164g to EN 54-7: 2000 + A1: 2002 Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors/Sensors


Certificated Products SLV-E(J) ALK-E(J) Conventional photoelectric smoke detector (YBN-R/4C base) Analogue addressable photoelectric smoke detector (YBN-R/2NA,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Conventional photoelectric smoke detector (YBN-R/4IS base) Conventional photoelectric smoke detector (YBF-RL/4H3, YBF-RL/4H5, YBF-RL/4H5H bases) Intelligent Analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent Analogue addressable optical smoke detector (White) (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent analogue addressable optical smoke detector (White) (YBN-R/3(HFP), YBO/R3SCI(HFP), YBO/BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and lower power modes Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent Analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)
1

LPCB Ref. No. 117h/01 117h/02

SLR-E-IS SLK-EN ALK-E

164g/02 164g/03 358c/03

ALK-E (WHT)

358c/03

ALK-E(HFP)

358c/03

ALK-EM

358c/03

ALG-EN

358c/04

200

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes ALG-EN (BLK) Intelligent Analogue addressable optical smoke detector(Black) (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent Analogue addressable optical smoke detector(White) (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector(White) (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector (White) (YBN-R/6(HFP) bases) Conventional optical smoke detector (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector(Black) (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) Conventional optical smoke detector(White) (YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases) 358c/04 LPCB Ref. No.

ALG-EN (WHT)

358c/04

ALG-ENM

358c/04

SLV-E3 SLV-E3 (WHT) SLV-E3(HFP) SLR-E3N SLR-E3N(BLK) SLR-E3N(WHT)

358c/05 358c/05 358c/05 358c/06 358c/06 358c/06

Bases YBO-R/SCI YBO-BS YBO-BSB YBO-R/6R YBO-R/6RS YBO-R/6RN YBO-R/6PA YBN-R/3 YBN-R/2NA YBN-R/6 YBN-R/6SK YBO-BS YBO-BSB Positive switching short circuit isolator base Sounder base Sounder base with Beacon Relay base Relay base latching with schottky diode Relay base non latching Protector alarms base Standard base Standard base Standard base Standard base with schottlky diode Sounder base Sounder base with Beacon

All Enquiries to: Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 Fax: +44 (0) 1634 260132

Manufacturing at (Certificate Nos 164, 164g, 164m) Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0) 1634 260131 Fax: +44 (0) 1634 260132 E-mail: sales@hochikieurope.com Website: www.hochikieurope.com

Certificate No: 164m to EN54-10:2002

12 Sep 2011

201

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Flame Detectors
Certificated Products IFD-E IFD-E(IS) IFD-E(EXD) Conventional IR Flame detector Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 Intrinsically Safe Flame Detector Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR 3 (Exd) Flameproof Flame Detector Note: Meets EN 54-10: 2002 at Class 1 only
3

LPCB Ref. No. 164m/01 164m/02 164m/03

Honeywell Automation (I) Pvt. Ltd


53, 54, 55 Hadapasar Indl. Estate, Hadapsar, Pune-411013, India Tel: +91 020 66780200 Fax: +91 020 66780172 E-mail: rahul.dwivedi@honeywell.com Website: www.myhoneywell.com
Certificate No: 550b to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021:1999

Multi-criteria Detectors
Certificated Products TC840ME Analogue optical/thermal smoke & heat detector (14506414-007 base) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R LPCB Ref. No. 550b/03

Bases; 1450614-007 Standard analogue detector base Certificate No: 550c to EN 54-5: 2000

Point Heat Detectors


Certificated Products TC808E1002M01 TC808E1028M01 Analogue addressable Class A1S fixed temperature heat detector (14506414-007 base) Analogue addressable Class A1R high temperature rate of rise heat detector (14506414007 base) LPCB Ref. No. 550c/04 550c/05

Bases: 14506414-007 Standard analogue detector base Certificate No: 550a to EN 54-7: 2000

Point Smoke Detectors


Certificated Products TC806E1012M01 Analogue addressable optical smoke detector (14506414-007 base) Notes: 1) Meets EN 54-7 with low, medium and high sensitivity settings LPCB Ref. No. 550a/03

Bases: 14506414-007 standard analogue detector base

Honeywell Control Systems Limited


Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: +44 (0)1344 655609 Fax: +44 (0)1344 655474 Website: www.honeywellbuildingsolutions.co.uk

202

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 199p-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificate No: 199aa-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005 Certificate No: 199t-(cl-1) to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-criteria Detectors
Certificated Products TC840MFEIS Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable optical/thermal smoke & heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Note: Meets the requirements of EN54-5: 2000 at class A1R and EN54-7: 2000 at sensitivity settings 1 to 5 Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501AP, B501DG, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS 1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Notes: 1.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 2.) Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): Nuisance Environment Applications: Application 0,Alarm Level 4 Application 1,Alarm Level 5 Application 2,Alarm Level 4 or 5 Application 3,Alarm Level 5 Application 4,Alarm Level 5 LPCB Ref. No. 199aa/01

TC840MEIS

199aa/02

TC840ME

199p/02

TC840MFE

199p/05

TC840MFES

199p/06

TC840MES

199p/07

TC850E1009-yy

199t/01

EN54-5 Class A1R, EN54-7, EN54-5 Class A1R

LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021

12 Sep 2011

203

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Application 5,Alarm Level 5 Application 6,Alarm Level 5 Application 7,Alarm Level 5 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, LPS1279 & CEA 4021 LPCB Ref. No.

Bases: B501 standard analogue detector base B501AP intelligent detector base B524IEFT analogue short circuit isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base

Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005

Beam Detectors
Certificated Products TC847A1004EUR 100m analogue addressable reflective IR smoke beam detector with self-test facility and short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199w/02

Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199n-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat Detectors


Certificated Products TC808EIS1002 TC808EIS1051 TC808EIS1028 TC808E 1002M01 TC808E 1028M01 TC808E1051M01 TC808ES1028 TC808ES1051 TC808ES1002 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Class A1S analogue addressable fixed temperature heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Class A1R analogue addressable rate of rise heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Class BS analogue addressable high temperature heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/03 199n/04 199n/05 199n/15 199n/16 199n/17

Bases: SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base B501 analogue detector base B501AP intelligent sensor base B501DG analogue deep base B524IEFT analogue short circuit isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base

204

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 Certificate No: 199m-(cl-1) to EN 54-7: 2000 + A1: 2002 Certificate No: 199ab-(cl-1) to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke Detectors/Sensors


Certificated Products TC846A1005 Analogue addressable laser optical detector (B501, B501DG & B524IEFT bases) Note: meets requirements of EN 54 Part 7 at sensitivity settings of 7 to 9 inclusive TC806EIS1012 Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity TC842B1007 AE Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP bases) Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity 199m/07 199ab/01 LPCB Ref. No. 118h/01

TC806ES1012

199m/10

Bases: B501 Analogue detector base B501DG Analogue deep base B501AP Intelligent detector base B524IEFT Analogue short circuit isolator base B524IEFT-1 Analogue short circuit isolator base B524HTR Heater Base B524RTE Latching relay base SIGI-IBS Isolator base SIGA-SB Standard Base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base SIGA-RB4 Relay base with trim skirt

Honeywell Control Systems Ltd


Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: 01344 655609 Fax: 01344 655474 Website: www.honeywellbuildingsolutions.co.uk
Certificate No: 262s to EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 1999 Certificate No: 262t to EN 54-7: 2000

Smoke Detectors
Certificated Products XLS-IPHSI Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4 & SIGA-AB4G bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2) The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases. Intelligent thermally enhanced photoelectric smoke detector (SIGA-SB, SIGA-SB4, SIGARB and SIGA-RB4 bases) Note: Meets the requirements of EN54-7: 2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, and 3/5%/ft. Intelligent ionisation smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB and SIGA-RB4 bases) LPCB Ref. No. 262s/01

XLS-PHSI

262s/02

XLS-ISI

262t/01

12 Sep 2011

205

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: Meets the requirements of EN54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft and 3.5%/ft Intelligent photoelectric smoke detector (SIGI-IBS, SIGA-SB4, SIGA-RB and SIGA-RB4 bases) Note: Meets the requirements of EN54-7: 2000 at sensitivity settings 10%/ft, 2%/ft, 2/5%/ft, 3%/ft and 3/5%/ft LPCB Ref. No. 262t/02

XLS-PSI

Bases SIGI-IBS isolator base SIGA-SB standard base SIGA-SB4 standard base with trim skirt SIGA-RB relay base SIGA-RB4 relay base

Certificate No: 262u to EN 54-5: 2000

Heat Detectors
Certificated Products XLS-HFSI XLS-HRSI Intelligent class A2S fixed heat detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB and SIGA-RB4 bases) Intelligent class A1 rate of rise heat detector (SIBI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, and SIGA-RB4 bases) LPCB Ref. No. 262u/01 262u/02

Bases SIGI-IBS Isolator base SIGA-SB Standard base SIGA-SB4 Standard base with trim skirt SIGA-RB Relay base

Horing LIH Industrial Co Ltd


No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC Tel: +886 2 22487599 Fax: +886 2 22407752
Certificate No: 506a to EN 54-7: 2000

Point Smoke Detectors


Certificated Products AHS-871 AH-0311-2 AH-0311-3 AH-0311-4 Bases: AHMB-031 mounting base AHMB-L mounting base Certificate No: 506b to EN 54-7: 2000, EN 54-5: 2000 & CEA 4021:1999 Conventional photoelectric smoke detector (AHMB-L mounting base) (2 wire) Conventional photoelectric smoke detector (AHMB-031 Base) (3 wire) Conventional photoelectric smoke detector (AHMB-031 Base) (4 wire) Conventional photoelectric smoke detector (AHMB-031 Base) LPCB Ref. No. 506a/01 506a/02 506a/03 506a/04

Multi-criteria Detectors
Certificated Products AH-0315-2 AH-0315-3 AH-0315-4 Bases: AHMB-031 mounting base (2 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (3 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (4 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) LPCB Ref. No. 506b/01 506b/02 506b/03

206

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 506c to EN 54-Part 5: 2000

Point Heat Detector


Certificated Products AH-0316-2 AH-0316-3 AH-0316-4 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 Base) (3 wire) Conventional three wire rate of rise and fixed temperature heat detector (AHMB031 Base) (4 wire) Conventional four wire rate of rise and fixed temperature heat detector (AHMB031 Base) LPCB Ref. No. 506c/01 506c/02 506c/03

Bases: AHMB-031 mounting base

Industrial Scientific Oldham


Rue Orfila - ZI Est - BP417, 62027 Arras Cedex, France Tel: +33 321 60 8130 Fax: +33 321 60 8000 E-mail: info@eu.indsci.com Website: www.groupoldham.com/site_en/fra
Certificate No: 911a-(cl-3) to EN54-10: 2002 + A1: 2005

Flame Detectors
Certificated Products 40/40R Conventional Class 1 single IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40R-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 1 triple IR (IR3) flame detector Notes: 1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters or numbers following the standard model number outlined respectively below e.g.40/40I-abcde) a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 1 quad IR flame detector Notes: 1. Meets the requirements of EN 54-10: 2002 Class 1at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40M-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below LPCB Ref. No. 911a/01

40/40I

911a/02

40/40M

911a/03

40/40L4B

911a/04

12 Sep 2011

207

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products e.g.40/40L4B-abcde): a. b. c. d. e. 40/40L4 LPCB Ref. No. Wiring options - 1 to 5 Maximum operating temperature - 1=75 C ; 2=85 C Cable entry - 1=M25 ; 2=3/4-14NPT Housing - S=Stainless steel ; A=Aluminium Approval - C= ATEX, IECEx; F= FM, CSA 911a/05

Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40LB-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40UB-abcde): a. Wiring options 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40U-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA

40/40LB

911a/06

40/40L

911a/07

40/40UB

911a/08

40/40U

911a/09

208

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

INIM Electronics s.r.l.


Via Fosso Antico - Loc, Centobuchi, 63033 Monteprandone (AP), Italy Tel: +39 0735 705007 Fax: +39 0735 704912 E-mail: enea.galiffa@inim.biz Website: www.inim.biz
Certificate No: 991d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 991c to EN 54-7: 2000 + A1:2002 + A2:2006

Smoke Detectors
Certificated Products ID100 Conventional optical smoke detector (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. LPCB Ref. No. 991c/01

ED100

Analogue addressable optical smoke detector with short circuit isolator (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.

991d/01

Bases: EB0010 Standard base EB0020 Relay base Certificate No: 991f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 991e to EN 54-5: 2000 + A1:2002

Heat Detectors
Certificated Products ID200 Conventional class P heat detector (EB0010 and EB0020 bases). Note: 1) Meets the requirements of EN54-5:2000 at class A1R & class B. LPCB Ref. No. 991e/01

ED200

Analogue addressable class P heat detector with short circuit isolator (EB0010 and EB0020 bases). Note: 1) Meets the requirements of EN54-5:2000 at class A1R & class B.

991f/01

Bases: EB0010 Standard base EB0020 Relay base

Certificate No: 991b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005 Certificate No: 991a to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1:2002 + A2:2006 and CEA4021: 2003

12 Sep 2011

209

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Multi-Criteria Detectors
Certificated Products ID300 Conventional multi-criteria detector (EB0010 and EB0020 bases). Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. 2) Meets the requirements of EN 54-5:2000 at class A1R & class B. Analogue addressable multi-criteria detector with short circuit isolator (EB0010 and EB0020 bases). LPCB Ref. No. 991a/01

ED300

991b/01

Note: 1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. 2) Meets the requirements of EN 54-5:2000 at class A1R & class B.

Bases: EB0010 Standard base EB0020 Relay base

Kidde Products Ltd


Thame Park Road, Thame, Oxfordshire OX9 3RT, United Kingdom Tel: +44 (0)1844 265003 Fax: +44 (0)1844 265156 E-mail: general.enquiries@kiddeuk.co.uk Website: www.kfp.co.uk
Certificate No: 404c to EN54-20: 2006

Aspirating Smoke Detectors


Certificated Products Senator 25 High sensitivity aspirating smoke detector Notes: 1) LPCB Ref. No. 404c/01

Senator 100

For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke detector Notes: 1)

404c/02

Senator 200

Senator 200

For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke standard detector (Senator 200 Stand Alone Command Module Ancillary) Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke command module detector Notes:

404c/03

404c/04

210

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating minimum display version smoke detector (Senator 200 Stand Alone Command Module Ancillary) Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. - The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No.

Senator 200

404c/05

Ancillaries: Senator 200 Stand Alone Command Module

Kidde Products Ltd, trading as AirSense Technology


Unit 1, Caxton Place, Caxton Way, Stevenage, Hertfordshire SG1 2UG, United Kingdom Tel: +44 (0)1462 751296 Fax: +44 (0)1462 729137 E-mail: tech@airsense.co.uk Website: www.airsense.co.uk/airsense
Certificate No: 404c to EN54-20: 2006 Certificated Products Stratos Micra 25 High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke detector Notes: 1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4. 2) The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. 3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating smoke standard detector (Stratos HSSD 2 Stand Alone Command Module Ancillary) Notes: The approval of the detectors is conditional upon the following requirements: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating command module smoke detector Notes: The approval of the detectors is conditional upon the following requirements: LPCB Ref. No. 404c/01

Stratos Micra 100

404c/02

Stratos HSSD 2

404c/03

Stratos HSSD 2

404c/04

12 Sep 2011

211

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating minimum display version smoke detector (Stratos HSSD 2 Stand Alone Command Module Ancillary) Notes: The approval of the detectors is conditional upon the following requirements: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. High sensitivity aspirating standard smoke detector 1, 2, 3 Notes: The approval of the detectors is conditional upon the following requirements: 1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4. 2. The approval of the detector is conditional upon the following requirements: Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.80%/m, 1.66%/m and 7.54%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No.

Stratos HSSD 2

404c/05

Stratos Nano

404c/06

Ancillaries: Stratos HSSD 2 Stand Alone Command Module

Labor Strauss Sicherungsanlagenbau GmbH


Wiegelestrasse 36, A-1231 Vienna, Austria Tel: +43 1 52114-44 Fax: +43 1 52114-27 E-mail: andreas.kurzweil@lst.at Website: www.lst.at
Certificate No: 928e-(cl-11) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products FC650/O Conventional Photo Detector (FC600/B, FC600/BR and FC600/BRD bases) LPCB Ref. No. 928e/02

Bases FC600/B FC600/BR FC600/BRD

Universal adaptor base Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode

Certificate No: 928d-(cl-11) to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products FC650/TDIFF/57 FC650/TMAX/78 Conventional Class A1R Thermal Detector (FC600/B, FC600/BR and FC600/BRD bases) Conventional Class B Thermal Detector (FC600/B, FC600/BR and FC600/BRD bases) LPCB Ref. No. 928d/02 928d/02

212

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases FC600/B FC600/BR FC600/BRD

Universal adaptor base Universal adaptor base with resistor Universal adaptor base with resistor and Schottky diode

Lichfield Fire & Safety Equipment Co. Ltd


2nd Floor, Suite 4, Saturn Centre, Spring Road, Ettingshall, Wolverhampton WV4 6JX, United Kingdom Tel: +44 (0)8700 664401 Fax: +44 (0)8700 664402 E-mail: info@lifeco-uk.com Website: lifeco-uk.com
Certificate No: 506c to EN 54-5: 2000

Point Heat Detectors


Certificated Products LFHD60 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB031 base) LPCB Ref. No. 506c/01

Bases: AHMB-031 mounting base Certificate No: 506a to EN 54-7: 2000

Photoelectric Smoke Detectors


Certificated Products LF-PE-4100 Bases: AHMB-L mounting base LF-PE-4100 Conventional photoelectric smoke detector (AHMB-L base) LPCB Ref. No. 506a/01

Mavili Elektronik Ticaret Ve Sanayi A.S.


Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey Tel: +90 216 4664 505 Fax: +90 216 4664 510 E-mail: mavili@mavili.com.tr Website: www.mavigard.com
Certificate No: 926a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products MG-9100 Intelligent analogue addressable system photoelectric smoke detector (MG-3510 base) LPCB Ref. No. 926a/01

Bases: MG-3510 standard mounting base

Certificate No: 926b to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products MG-9300 Intelligent analogue addressable system class A1R rate of rise heat detector (MG-3510 base) LPCB Ref. No. 926b/01

Bases: MG-3510 standard mounting base

12 Sep 2011

213

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 926c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-criteria Detectors
Certificated Products MG-9400 Intelligent analogue addressable system class A1R multisensor detector (MG-3510 base) LPCB Ref. No. 926c/01

Bases: MG-3510 standard mounting base

Morley-IAS Fire Systems By Honeywell


Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@morleyias.co.uk Website: www.morley-ias.co.uk
Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat Detectors


Certificated Products MI-FHSE-S2I MI-HTSE-S2I MI-RHSE-S2I MI-FHSE MI-RHSE MI-HTSE HRZ-1005T HRZ-1004T HRZ-1005 MI-RHSE-S2 MI-HTSE-S2 MI-FHSE-S2 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Class A1S analogue addressable fixed temperature heat detector (B501, B501DG and B524IEFT bases) Class AIR analogue addressable rate of rise heat detector (B501, B501DG and B524IEFT bases) Class BS analogue addressable high temperature heat detector (B501, B501DG and B524IEFT bases) Class A2S conventional fixed temperature heat detector (HRZ-1000BSD base) Class BS conventional fixed temperature heat detector (HRZ-1000BSD base) Class A1R conventional rate of rise heat detector (HRZ-1000BSD base) Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/03 199n/04 199n/05 199n/10 199n/11 199n/12 199n/15 199n/16 199n/17

Bases: B501 standard analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base B501AP intelligent sensor base B524IEFT-1 short circuit isolator B524HTR heater base B524RTE latching relay base HRZ-1000BSD standard base with Schottky diode Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005

Multi-criteria Detectors
Certificated Products MI-PTIR-S2I Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) LPCB Ref. No. 199aa/01

214

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable optical/thermal smoke & heat detector (B501, B501DG & B524IEFT bases) Meets the requirements of EN54-5: 2000 at class A1R and EN54-7: 2000 at sensitivity settings 1 to 5 Conventional photo thermal detector (HRZ-1000BSD base) Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Bases: B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue short circuit isolator base B524IEFT-1 analogue sensor short circuit isolator base B524HTR heater base B524RTE latching relay base HRZ-1000BSD standard base with Schottky diode Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005 LPCB Ref. No.

MI-PTSE-S2I

199aa/02

MI-PTSE

199p/02

HRZ-1002 MI-PTIR

199p/04 199p/05

MI-PTIR-S2

199p/06

MI-PTSE-S2

199p/07

Point Smoke Detectors


Certificated Products MI-LZR MI-PSE-S2I MI-PSE HRZ-1003 MI-PSE-S2 Analogue addressable photoelectric laser smoke detector (B501, B501DG and B524IEFT bases) Meets the requirements of EN 54-7 at sensitivity settings of 7 to 9 inclusive.Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Analogue optical detector (B501, B501DG and B524IEFT bases) Meets EN 54-7: 2000 with 'low', 'medium' and 'high' sensitivities Conventional photoelectric detector (HRZ-1000BSD base) Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity LPCB Ref. No. 118h/01 199ab/01 199m/02 199m/05 199m/10

12 Sep 2011

215

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products LPCB Ref. No.

Bases: B501 analogue detector base B501DG analogue deep base B524IEFT analogue short circuit isolator base B501AP intelligent sensor base B524IEFT-1 short circuit isolator base B524HTR heater base B524RTE latching relay base HRZ-1000BSD standard base with Schottky diode Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005

Beam Detectors
Certificated Products MI-LPB2 Analogue optical beam detector with short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199w/01

Morley-IAS Fire Systems By Honeywell


Honeywell Fire Systems, BSEL Tech Park, Floor 6,Sector 30A, Opposite Vshi Station, Vashi, New Mumbai, India Tel: +91 022 67122427 Fax: +91 022 67122422 E-mail: rk.raman@honeywell.com Website: www.myhoneywell.com
Certificate No: 550b to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021:1999

Multi-criteria Detectors
Certificated Products MI-PTSE Analogue optical/thermal smoke & heat detector (MI-B501 base) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R LPCB Ref. No. 550b/03

Bases: MI-B501 Standard analogue detector base Certificate No: 550c to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products MI-FHSE MI-RHSE Analogue addressable Class A1S fixed temperature heat detector (MI-B501 base) Analogue addressable Class A1R high temperature rate of rise heat detector (MI-B501 base) LPCB Ref. No. 550c/04 550c/05

Bases: MI-B501 Standard analogue detector base Certificate No: 550a to EN 54-7: 2000 + A1: 2002

Point Smoke Detectors


Certificated Products MI-PSE Analogue addressable optical smoke detector (MI-B501 base) Note: Meets EN 54-7 with low, medium and high sensitivity settings LPCB Ref. No. 550a/03

216

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases MI-B501 standard analogue detector base

MSA AUER
Thiemannstrae 1, 12059 Berlin, Germany Tel: +49 30 6886 2531 Fax: +49 30 6886 2582 E-mail: axel.schubert@auer.de Website: www.msa-auer.de
Certificate No: 911a-(cl-2) to EN 54-10: 2002 + A1: 2005

Flame Detectors
Certificated Products 4R Conventional Class 1 single IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4R-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 1 triple IR (IR3) flame detector Notes: 1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters or numbers following the standard model number outlined respectively below e.g.4I-abcde) a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 1 quad IR flame detector Notes: 1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4M-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4L4B-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4L4-abcde): a. Wiring options - 1 to 5 LPCB Ref. No. 911a/01

4I

911a/02

4M

911a/03

4L4B

911a/04

4L4

911a/05

12 Sep 2011

217

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products b. c. d. e. 4LB Maximum operating temperature - 1=75 C ; 2=85 C Cable entry - 1=M25 ; 2=3/4-14NPT Housing - S=Stainless steel ; A=Aluminium Approval - C= ATEX, IECEx; F= FM, CSA LPCB Ref. No.

Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4LB-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4L-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4UB-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4U-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA

911a/06

4L

911a/07

4UB

911a/08

4U

911a/09

Multron Systems Pte Ltd


217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 Fax: +65 6743 2777 / 6395 6869 E-mail: info@multron.com Website: www.multron.com
Certificate No: 548c-(cl-6) to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products DET-C103 DET-A103 Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R heat detector (DZ-03 base) LPCB Ref. No. 548c/01 548c/02

Bases:

218

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
DZ-03 Standard detector base Certificate No: 548d-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Photoelectric Smoke Detectors


Certificated Products DET-C102 DET-A102 Conventional Photoelectric Smoke Detector (DZ-03 base) Intelligent Photoelectric Smoke Detector (DZ-03 base) LPCB Ref. No. 548d/01 548d/02

Bases: DZ-03 Standard detector base Certificate No: 548k-(cl-6) to EN 54-12: 2002

Beam Detectors
Certificated Products DET-105RB Intelligent Optical Beam Detector Notes: 1: Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 1.61 dBLevel 2 2.31dB LPCB Ref. No. 548k/01

Nitin Ventures FZE


P.O. Box 262294, Jabel Ali Free Zone, Dubai, United Arab Emirates Tel: +97 148865858/859 Fax: +97 148865800 E-mail: sales@nitinventures.com Website: www.nitinventures.com
Certificate No: 010h-(cl-1) to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products NV-I-MS Analogue addressable multisensor detector (NV-IA-SB mounting base) Notes: 1) Certificated at the following settings: Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5. LPCB Ref. No. 010h/01

Bases: NV-IA-SB Mounting Base Certificate No: 010p-(cl-1) to EN 54-5: 2000 +A1: 2002

Point Heat Detectors


Certificated Products NV-I-H Analogue addressable heat detector (NV-IA-SB mounting base) Notes: 1) Meets the requirements of EN54: Part 5 Class A1R in mode 1 and in conventional mode Class A2 in mode 2 and in conventional mode Class A2S in mode 3 and in conventional mode Class CR in mode 4 and in conventional mode Class CS in mode 5 and in conventional mode. Conventional class A1R heat detector - flashing LED (NV-C-SB mounting base) Notes: LPCB Ref. No. 010p/03

NV-C-H-A1R

010p/05

12 Sep 2011

219

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 1) Meets the requirements of EN54: Part 5 - Class A1R Bases: NV-IA-SB mounting base NV-C-SB mounting base Certificate No: 010q-(cl-1) to EN 54-7: 2000 + A1: 2002 LPCB Ref. No.

Point Smoke Detectors


Certificated Products NV-I-I NV-I-O NV-C-I NV-C-O Bases: NV-IA-SB mounting base NV-C-SB mounting base Analogue addressable ionisation smoke detector (NV-IA-SB mounting base) Notes: 1) Meets the requirements of EN54-7: 2000 in modes 1,2,3,4 and 5 in conventional mode Analogue addressable optical smoke detector (NV-IA-SB mounting base) Notes: 1) Meets the requirements of EN54-7:2000 in modes 1,2,3 4 and 5 in conventional mode Conventional ionisation smoke detector - flashing LED (NV-C-SB mounting base) Conventional optical smoke detector- flashing LED (NV-C-SB mounting base) LPCB Ref. No. 010q/02 010q/03 010q/05 010q/11

Nittan (UK) Limited


Hipley Street, Old Woking, Surrey GU22 9LQ, United Kingdom Tel: +44 (0)1483 769555/8 Fax: +44 (0)1483 756686 E-mail: sales@nittan.co.uk Website: www.nittan.co.uk
Certificate No: 041f to EN54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 842a-(cl-1) to EN-54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 755a-(cl-1) to EN54-7: 2000 + A1: 2002

Point Smoke Detectors


Certificated Products EV-P EVC-P EVC-DP EVC-P ST-P-OM ST-PY-AS EV-P Analogue addressable optical smoke detector (UB-4,UB-4-EV,UB-4-SD and STB-4SEEV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. EVC-P Conventional optical smoke detector (STB-4-SE-24VR, STB-4SE, UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Conventional Dual Optical Smoke Detector (STB-4, STB-4SD, STB-4SE, STB-4SE-24VR, UB-4 and UB-5 bases) Conventional optical smoke detector (STB-4-SE24VR, STB-4-SE ,STB-4 , UB-4 and UB-4SD bases) Conventional optical smoke detector (STB-4-SE24VR, STB-4-SE ,STB-4, UB-4 , UB-4R470 and UB-4SDR470 bases) Analogue addressable photoelectric smoke detector (STB-4-SE ,STB-4 and UB-4 bases) Analogue addressable photoelectric smoke detector ,STB-4-SE-EV and UB4-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. LPCB Ref. No. 041f/01 041f/03 755a/01 842a/01 842a/02 842a/03 842a/04

Bases STB-4 Standard mounting base STB-4SE-EV mounting base STB-4SE Standard deep mounting base STB-4SD Schottky diode mounting base STB-4-SE-24VR Relay mounting base UB-4 Universal mounting base 4 terminal UB-5 Universal mounting base 5 terminal UB-4-EV Universal base UB-4SD Universal base with Shottky diode

220

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 041h to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products EV-H-A1R EV-H-CS EVC-H-A2S EVC-H-CS Analogue addressable Class A1R heat detector (UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Analogue addressable Class CS heat detector and STB-4SE-EV bases) Analogue addressable Class A2S heat detector (UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Analogue addressable Class CS heat detector and STB-4SE-EV bases) LPCB Ref. No. 041h/01 041h/02 041h/03 041h/04

Bases UB-4 Universal base UB-4-EV Universal base UB-4SD Universal base with Shottky diode STB-4SE-EV mounting base

Certificate No: 041g to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1:2002 + A2: 2006 and CEA4021: 1999

Multi-criteria Detectors
Certificated Products EV-PH Analogue addressable optical smoke / class A1R heat detector (UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings. LPCB Ref. No. 041g/01

Bases UB-4 Universal base UB-4-EV Universal base UB-4SD Universal base with Shottky diode STB-4SE-EV mounting base

Nittan Fire Protection (Zhongshan) Co Ltd


2nd Floor, No 29 Building, New Concentrated Construction Quarter, Zhongshan Torch Hi-Tec Industrial Development Zone, Zhongshan, Guangdong, 8285701, China
Certificate No: 842a to EN54-7:2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products EVC-P ST-P-OM ST-PY-AS EV-P Conventional optical smoke detector (STB-4-SE-24VR,STB-4SE, STB-4SE-EV,UB-4,UB-4-EV and UB-4SD bases) Conventional optical smoke detector (STB-4-SE-24VR, STB-4SE ,STB-4, UB-4 , UB-4R470 and UB-4SDR-470 bases) Analogue addressable photoelectric smoke detector ,STB-4 and UB-4 bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings. Analogue addressable photoelectric smoke detector UB-4SD bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only. LPCB Ref. No. 842a/01 842a/02 842a/03 842a/04

Bases STB-4SE-EV mounting base STB-4SE Standard deep base STB-4-SE-24VR Relay base UB-4 universal base UB-4-EV universal base

12 Sep 2011

221

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
UB-4SD Standard base with Schottky diode UB-4R-470 Standard base with 470 ohm resistor UB-4SDR-470 Standard base with Schottky diode and 470 ohm resistor UB-4-EV mounting base

Notifier Fire Systems by Honeywell


Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 199m to EN 54-7: 2000 + A1: 2002 Certificate No: 118h to EN 54-7: 2000 + A1: 2002 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke Detectors


Certificated Products FSL-751E NFXI-OPT SDX-751EM SD-851E IDX-751 AE Analogue addressable photoelectric laser smoke detector (B501, B501DG & B5241EFT bases) Note: meets the requirements of EN 54:Part 7 at sensitivity settings of 7 to 9 inclusive. Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Analogue optical smoke detector smoke detector (B501, B501DG and B5241EFT bases) Note: Meets EN54-7 with 'low', 'medium' and 'high' sensitivity settings Conventional photoelectric smoke detector (B401 base) Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP bases) Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000DB, ECO1000DBR and ECO1000DBRSD LPCB Ref. No. 118h/01 199ab/01 199m/02 199m/03 199m/07

NFX-OPT ECO1003ABL

199m/10 199m/11

Bases: B501 base B401 base B501DG deep base B5241EFT short circuit isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base B501AP Intelligent detector base Certificate No: 199n to EN 54-5: 2000 + A1:2002 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat Detectors


Certificated Products NFXI-TFIX58 NFXI-TFIX78 NFXI-TDIFF FDX-551EM FDX-551REM FDX-551HTEM FD-851RE Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Class A1S analogue addressable fixed temperature heat detector (B501, B501DG and B5241EFT bases) Class A1R analogue addressable high temp rate of rise heat detector (B501, B501DG and B5241EFT bases) Class BS analogue addressable high temperature heat detector (B501, B501DG and B5241EFT bases) Conventional Class A1R rate of rise heat detector (B401 base) LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/03 199n/04 199n/05 199n/07

222

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products FD-851HTE FD-851TE NFX-TDIFF NFX-TFIX78 NFX-TFIX58 ECO1004TABL Conventional Class BS heat detector (B401 base) Conventional class A2S fixed temperature heat detector (B401, B401R, B401RSD, B401SD, B401DG bases) Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Class BS conventional high temperature heat detector (ECO1000DB, ECO1000DBR, ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Class A1R conventional thermal detector (ECO1000DB, ECO1000DBR, ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Class A2S conventional fixed temperature heat detector (ECO1000DB, ECO1000DBR, ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) LPCB Ref. No. 199n/08 199n/14 199n/15 199n/16 199n/17 199n/18

ECO1005ABL

199n/19

ECO1005TABL

199n/20

Bases: B501 base B401 base B401R standard base with resistor B401RSD standard base with resistor and schottky diode B401SD standard base with schottky diode B401DG deep base B501AP intelligent sensor base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005

Multi-criteria Detectors
Certificated Products NFXI-SMT3 Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable optical/thermal smoke & heat detector (B501, B501DG and B5241EFT bases) Conventional photoelectric/thermal detector (B401 base) Note: Meets the requirements of EN54-7: 2000 at "High", 'Medium' and 'Low' sensitivity settings Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR & B524RTE bases) Note: Certified at the following settings: LPCB Ref. No. 199aa/01

NFXI-SMT2

199aa/02

SDX-751TEM SD-851TE IRX-751TEM

199p/02 199p/03 199p/05

NFX-SMT3

199p/06

12 Sep 2011

223

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R NFX-SMT2 Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Note :Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set sensitivity Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 Bases: B501 base B401 base B501DG deep base B524IEFT-1 analogue short circuit isolator base B501AP intelligent sensor base B524HTR heater base B524RTE latching relay base Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005 199p/07 LPCB Ref. No.

ECO1002ABL

199p/08

IRX-751CTEM

199t/01

EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021

Beam Detectors
Certificated Products LPB-400 Analogue optical beam detector with short circuit isolator feature. Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 Analogue optical beam detector with short circuit isolator feature. Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 Analogue optical beam detector with self test facility and short circuit isolator feature. Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199w/01

LPB-700

199w/01

LPB-700T

199w/02

224

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Notifier Fire Systems India


Honeywell Fire Systems, BSEL Tech Park, Floor 6, 603, Sector 30A, opposite Vashi Station, Vashi, New Mumbia, India Tel: +91 022 67122427 Fax: +91 02267122422 E-mail: rk.raman@honeywell.com Website: www.myhoneywell.com
Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021:1999

Multi-criteria Detectors
Certificated Products SDX-751TEM Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1 bases) Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5:2000 at Class A1R LPCB Ref. No. 550b/03

Bases: B501 Standard base B501DG Deep analogue detector base B5242EFT-1 Short circuit islolator base

Certificate No: 550c to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products FDX-551EM FDX-551REM Analogue addressable Class A1S fixed temperature heat detector (B501, B501DG and B5241EFT-1 bases) Analogue addressable Class A1R high temperature rate of rise heat detector (B501, B501DG and B5241EFT-1 bases) LPCB Ref. No. 550c/04 550c/05

B501 Standard base B501DG Deep analogue detector base B542IEFT-1 Short circuit islolator base Certificate No: 550a to EN 54-7: 2000 + A1: 2002

Point Smoke Detectors


Certificated Products SDX-751EM Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases) Notes: 1) Meets EN 54-7 with low, medium and high sensitivity settings LPCB Ref. No. 550a/03

Bases: B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base

OG Elektronik
Sanayi Mah., 636 Sok., Erol Apt. 11/3, Antalya, Turkey Tel: +9 0242 344 2500 Fax: +9 0242 344 2120 E-mail: info@og.com.tr; ahmet@og.com.tr Website: www.og.com.tr
Certificate No: 928a-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005 Certificate No: 928d-(cl-1) to EN 54-5: 2000 + A1: 2002

12 Sep 2011

225

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Heat Detectors
Certificated Products FF T200 FF T200L FF T1000 Analogue addressable Class P heat detector with short circuit isolator (FF BS200 base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P, temperature detector (FF BS200 base) Notes 1. Meets the requirements of EN 54-5 for Class A1R and Class B Conventional Class P, heat detector (FF UBR200 and FF BRD200 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. LPCB Ref. No. 928a/01 928d/01 928d/02

Bases FF BS200 Mounting base (with link resistor) FF UBR200 Universal adaptor base with resistor FF BRD200 Universal adaptor base with resistor and Schottky diode

Certificate No: 928b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005 Certificate No: 928e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products FF O200 Analogue addressable photoelectric smoke detector with short circuit isolator (FF BS200 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low FF O200L Analogue addressable optical smoke detector (FF BS200 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low FF O1000 Conventional photo smoke detector (FF UBR200 and FF BRD200 bases) 928e/02 928e/01 LPCB Ref. No. 928b/01

Bases FF BS200 Mounting base (with link resistor) FF UBR200 Universal adaptor base with resistor FF BRD200 Universal adaptor base with resistor and Schottky diode

Certificate No: 928c-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003 Certificate No: 928f-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Multi-sensor Detectors
Certificated Products FT OT200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (FF BS200 base) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 Thermally enhanced smoke detection with Class A1 LPCB Ref. No. 928c/01

226

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products heat response Multi Criteria Level 4 (least sensitive) Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 High Optical only level 2 Optical only level 3 Optical only level 4 Low Analogue addressable optical smoke detector (FF BS200 base) Notes 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No.

FF OT200L

928f/01

Bases FF BS200 Mounting base (with link resistor)

Pelco Finland Oy
Kalkkipellontie 6, PO Box 415, Fl-02601 Espoo, Finland Tel: +358 10 446 511 Fax: +358 10 446 5103 Website: www.pelco.com/nordic
Certificate No: 199u to EN 54-12: 2002 Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005

Beam Detectors
Certificated Products EB-6500R Conventional optical beam detector Note: 1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Conventional optical beam detector with self test facility Note: 1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Analogue optical beam detector with short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 Analogue optical beam detector with self test facility and short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2 LPCB Ref. No. 199u/01

EB-6500RS

199u/02

EB-6500 EB-6500S

199w/01 199w/02

Certificate No: 199m to EN 54-7: 2000 + A1: 2002

Point Smoke Detectors


Certificated Products ESMI2251EM ED2351E Analogue optical detector (B501, B501DG, B524IEFT, B524HTR and B524RTE bases) Note: Meets EN 54-7:2000 with low, medium and high sensitivities Conventional photoelectric detector (B401, B401DG, B401R, B401SD and B401RSD bases) Note: 1. Meets EN 54-7: 2000 with Low, Medium and High sensitivites LPCB Ref. No. 199m/02 199m/03

12 Sep 2011

227

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases: B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 Analogue sensor base B501DG Analogue sensor deep base B524IEFT Analogue sensor isolator base B524HTR Heater base B524RTE Latching relay base

Certificate No: 199n to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products ESMI5251EM ESMI5251REM ESMI5251HTEM ED5351E ED4351E ED5351TE Class A1S analogue addressable fixed temperature heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Class A1R analogue addressable rate of rise heat detector B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Class BS analogue addressable high temperature heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Class A1R conventional rate of rise heat detector (B401, B401DG, B401R and B401RSD bases) Class BS conventional heat detector (B401, B401DG, B401R, B401SD and B401RSD bases) Class A2S conventional fixed temperature heat detector (B401, B401R, B401RSD, B401SD and B401DG bases) LPCB Ref. No. 199n/03 199n/04 199n/05 199n/07 199n/08 199n/14

Bases: B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 analogue sensor base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base

Certificate No: 199p to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003

Multi Criteria Detectors


Certificated Products ESMI2251TEM Analogue addressable optical/thermal smoke & heat detector (B501, B501AP, B501DG, B524IEFT, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at sensitivity settings 1 to 5 Conventional optical/thermal smoke & heat detector (B401, B401DG, B401R, B401SD and B401RSD bases) Note: 1. Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at High, Medium and Low. Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases) Note: Certified at the following settings:Normal Mode: Alarm Levels 1 to 5 (Mult-criteria): EN54-5 Class A1R, EN54-7 AND CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Analogue addressable multi-criteria fire detector and incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases) LPCB Ref. No. 199p/02

ED2351TEM

199p/03

ESMI2251TLE

199p/05

ESMI2251CTLE

199t/01

228

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products LPCB Ref. No.

Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 Bases: B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG Deep detector base B524IEFT Short circuit isolator base B524HTR Heater base B524RTE Latching relay base

EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021

Philton Fire & Security Limited


61 Lower Road, Harrow, Middlesex HA2 0DE, United Kingdom Tel: +44(0) 20-8864-7534 Fax: +44(0) 20 8864 8631 E-mail: james.colyer@philton.com Website: www.philton.com
Certificate No: 404c to EN54-20:2006

Aspirating Smoke Detecors


Certificated Products Guardian LaserSTAMP high sensitivity aspirating smoke detector Notes: 1. 2. 3. For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply complying with EN 54-4. The approval of the detector is conditional upon the following requirements: - Design, installation and commissioning are performed in accordance with the system design manual and instructions. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD. LPCB Ref. No. 404c/01

12 Sep 2011

229

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Pittway Tecnologica Srl.


Via Caboto 19/3, 34147 Trieste, Italy Tel: +39 040 94 90111 Fax: +39 040 38 2137 E-mail: sandro_bonin@systemsensor.com Website: www.systemsensoreurope.com European Sales: System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, Switzerland Tel: +41 44 943 4424 Fax: +41 44 943 4399 E-mail: sse.marketing@systemsensor.com Website: www.systemsensoreurope.com

Certificate No: 199m to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke Detectors


Certificated Products 22051EI ECO1003 2251EM 2351E Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity Conventional photoelectric smoke detector (ECO1000DB, ECO1000DBR and ECO1000DBRSD) Analogue optical smoke detector (B501, B501AP, B501DG, B5241EFT, B524HTR and B524RTE bases) Note: Meets EN54-7 with 'low', 'medium' and 'high' sensitivity settings Conventional photoelectric smoke detector (B401, B40DG, B401R, B401SD and B401RSD bases) Note: Meets the requirements of EN54-7:2000 at 'low', 'medium' and 'high' sensitivity settings Conventional photoelectric detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP, B524HTR and B524RTE bases) Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings Intrinsically safe conventional ionisation smoke detector (B401 base) Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases) Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity LPCB Ref. No. 199ab/01 199m/01 199m/02 199m/03

Vision 2020P 22051EISE

199m/05 199m/07

1151EIS 22051E

199m/08 199m/10

Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base ECO1000B standard base. ECO1000BSD standard base with schottky diode. ECO1000BR standard base, 470 ohm resistor. ECO1000BRSD standard base, 470 ohm resistor and schottky diode. ECO1000BR680 standard base, 680 ohm resistor. ECO1000BR680SD standard base, 680 ohm resistor and schottky diode. ECO1000BR1000 standard base, 1000 ohm resistor. ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode. ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor

230

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
ECO1000DBRSD deep base with 470 ohm resistor and schottky diode ECO2000B mounting base. Certificate No: 199n to EN 54-5: 2000 + A1: 2002 Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat Detectors


Certificated Products 52051EI 52051HTEI 52051REI ECO1005 5251EM 5251REM 5251HTEM ECO1005T Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases) Class A1R conventional thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Class A1S analogue addressable fixed temperature heat detector (B501, B501AP, B501DG, B5241EFT, B524HTR and B524RTE bases) Class A1R analogue addressable high temp rate of rise heat detector B501AP, B501DG, B524HTR and B524RTE bases) Class BS analogue addressable high temperature heat detector B501AP, B501DG, B524HTR and B524RTE bases) Class A2S conventional fixed temperature heat detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Class A1R conventional rate of rise heat detector (B401, B401DG, B401R, B401SD, & B401RSD bases) Class BS conventional heat detector (B401, B401 DG, B401R, B401SD, & B401RSD bases) Class BS conventional high temperature heat detector (ECO1000DB, ECO1000DBR, ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Class A2S conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Class BS conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Class A1R conventional rate of rise heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) Intrinsically safe conventional A1R heat detector (B401 base) Conventional class A2S fixed temperature heat detector (B401, B401R, B401RSD, B401SD, B401DG bases) Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class BS fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) LPCB Ref. No. 199ac/01 199ac/02 199ac/03 199n/01 199n/03 199n/04 199n/05 199n/06

5351E 4351E ECO1004T Vision 2020F Vision 2020HF Vision 2020R 5451EIS 5351TE 52051RE 52051HTE 52051E

199n/07 199n/08 199n/09 199n/10 199n/11 199n/12 199n/13 199n/14 199n/15 199n/16 199n/17

Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base

12 Sep 2011

231

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
ECO1000B standard base. ECO1000BSD standard base with schottky diode. ECO1000BR standard base, 470 ohm resistor. ECO1000BRSD standard base, 470 ohm resistor and schottky diode. ECO1000BR680 standard base, 680 ohm resistor. ECO1000BR680SD standard base, 680 ohm resistor and schottky diode. ECO1000BR1000 standard base, 1000 ohm resistor. ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode. ECO2000B mounting base. ECO1000DB deep base. ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode. Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003 Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2006 & CEA 4021: 2003 Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005

Multi-criteria Detectors
Certificated Products 22051TLEI Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases) Note :Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set sensitivity Analogue addressable optical/thermal smoke & heat detector B501AP, B501DG, B524HTR and B524RTE bases) Note: Meets the requirements of EN 54-5:2000 at class A1R and EN 54-7:2000 at sensitivity settings 1 to 5 Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, & B401RSD bases) Note: Meets the requirements of EN54-5:2000 at class A1R and EN54-7:2000 at 'High' 'Medium' and 'Low' sensitivity settings. Conventional photo thermal detector (2020B, 2020DB, 2020BSD and 2020DBSD bases) Analogue addressable multi-criteria detector incorporating photoelectric, thermal and IR sensors (B501, B501AP, B501DG, B524HTR and B524RTE bases) Note: Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: Certified at the following settings: Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1.) xx = (Range 0-99) ~ indicates the communication software protocol LPCB Ref. No. 199aa/01

22051TEI

199aa/02

ECO1002

199p/01

2251TEM

199p/02

2351TEM

199p/03

Vision 2020PT 2251TLE

199p/04 199p/05

22051TLE

199p/06

22051TE

199p/07

2251CTLE-xx-yy

199t/01

232

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 2.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White 3.) Certified at the following settings: Normal Mode: Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R Nuisance Environment Applications: Application 0, Alarm Level 4 Application 1, Alarm Level 5 Application 2, Alarm Level 4 or 5 Application 3, Alarm Level 5 Application 4, Alarm Level 5 Application 5, Alarm Level 5 Application 6, Alarm Level 5 Application 7, Alarm Level 5 LPCB Ref. No.

EN54-7, LPS1279 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-7 & CEA 4021 EN54-5 Class A1R, EN54-7 & CEA 4021 EN54-5 Class A1R, LPS1279 and CEA 4021

Bases: 2020B standard base 2020DB deep base 2020BSD standard base with schottky diode 2020DBSD deep base with schottky diode B401 standard base B401DG deep base B401R standard base with 470 ohm resistor B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode B501 standard analogue detector base B501AP intelligent detector base B501DG analogue sensor deep base B524IEFT analogue sensor isolator base B524IEFT-1 analogue short circuit isolator base B524HTR heater base B524RTE latching relay base ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode ECO2000B mounting base

Certificate No: 199u to EN 54-12: 2002 Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005

Beam Detectors
Certificated Products 6500R 6500RS 6500 Conventional optical beam detector Note: meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Conventional optical beam detector with self test facility Note: meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2 Analogue optical beam detector with short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and Acclimate levels 1 & 2 LPCB Ref. No. 199u/01 199u/02 199w/01

12 Sep 2011

233

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 6500S Analogue optical beam detector with self test facility and short circuit isolator feature Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and Acclimate levels 1 & 2 LPCB Ref. No. 199w/02

Plana Fabrega
C/Caracas, 08030, Barcelona, Spain Tel: 0034 93 243 1111 Fax: 0034 93 243 0350 E-mail: jgarcia@planafabrega.com; rseome@planafabrega.com
Certificate No: 199m to EN 54-7: 2000 + A1: 2002

Smoke Detectors
Certificated Products OPT1 Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR, ECO1000DBRSD bases) LPCB Ref. No. 199m/01

ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode

Certificate No: 199n to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products TEVOL Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR, ECO1000DBRSD bases) LPCB Ref. No. 199n/01

ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode ECO1000DB deep base ECO1000DBR deep base with 470 ohm resistor ECO1000DBRSD deep base with 470 ohm resistor and schottky diode

234

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Protec Fire Detection plc


Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 Fax: +44 (0)1282 717273 E-mail: sales@protec.co.uk Website: www.protec.co.uk
Certificate No: 201f to EN 54-7: 2000 Certificate No: 201p to EN 54-7: 2000 Certificate No: 201ab to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 201v to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products 6000PLUS/OP/S Analogue addressable smoke detector with indoor sounder and short circuit isolator (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms Analogue addressable smoke detector with indoor sounder and short circuit isolator (export) (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s Conventional ionisation smoke detector (3000/BASE) Conventional optical smoke detector (3000/BASE) MK II Analogue addressable optical smoke detector (6000/BASE and 6000/DIB bases) Note: Meets requirements of EN 54-7: 2000 at the following mode settings: i. Normal sensitivity mode Analogue addressable smoke detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting LPCB Ref. No. 201ab/01

6000PLUS/OP/SX

201ab/02

3000/ION 3000/OP Mk II 6000/OP 6000PLUS/OP

201f/01 201f/04 201p/01 201v/01

Bases: 6000/BASE standard low profile base 6000/DIB isolator base 3000/BASE Standard Base 6000PLUS/BASE, standard mounting base 6000PLUS/FFBASE, recessed mounting base N28-075-01, Plug and Play Fast Fix base N28-075-02, Plug and Play Surface base

Certificate No: 201g to EN 54-5: 2000 + A1: 2002 Certificate No: 201r to EN 54-5: 2000 Certificate No: 201w to EN 54-5: 2000 + A1: 2002 Certificate No: 201aa to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Point Heat Detectors


Certificated Products 6000PLUS/HT/S Analogue addressable heat detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms Analogue addressable heat detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) LPCB Ref. No. 201aa/01

6000PLUS/HT/SL

201aa/02

12 Sep 2011

235

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 3) The beacon functionality is not included within the scope of this approval 6000PLUS/HT/TSL Analogue addressable heat detector with talking indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 2) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. 3) The beacon functionality is not included within the scope of this approval Conventional class A1 rate of rise and fixed temperature heat detector (3000/BASE) Conventional class A2 rate of rise fixed temperature (3000/BASE) Analogue addressable heat detector (6000/BASE & 6000/DIB bases) Note: Meets requirements of EN 54-5: 2000 at Class A1 (High sensitivity) and A2 (Normal sensitivity). Analogue addressable heat detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-07501 and N28-075-02 bases) Note: Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2 201aa/03 LPCB Ref. No.

3000/TEMP56 3000/TEMP64 6000/TEMP 6000PLUS/HT

201g/01 201g/02 201r/01 201w/01

Bases: 3000/BASE standard base 6000/BASE standard low profile base 6000/DIB isolator base 6000PLUS/BASE, standard mounting base 6000PLUS/FFBASE, recessed mounting base N28-075-01, Plug and Play Fast Fix base N28-075-02, Plug and Play Surface base

Certificate No: 201j to EN 54: Part 5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 2003 Certificate No: 201q to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021 Certificate No: 201s to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021 Certificate No: 201u to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 Certificate No: 201x to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 201y to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003 Certificate No: 201z to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 201ac to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003

Multi-criteria Detectors
Certificated Products 6000PLUS/OPHT/I Analogue addressable multisensor detector with short circuit isolator (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings Conventional optical smoke and Class A2 heat detector (3000/BASE) Analogue addressable optical smoke and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases). Note: 1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only: i) Normal sensitivity mode ii) Low sensitivity mode Analogue addressable optical smoke, CO and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases) Notes: 1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode LPCB Ref. No. 201ac/01

3000/OPHT Mk II 6000/OPHT Mk II

201j/01 201q/01

6000/OPHTCO

201s/01

236

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products settings only: i) Normal sensitivity mode II) Low sensitivity mode 2) The CO element is not LPCB approved Analogue addressable multisensor detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings Analogue addressable multisensor detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms Analogue addressable multisensor detector with indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s Analogue addressable multisensor detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The beacon functionality is not included within the scope of this approval Analogue addressable multisensor detector with talking indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice Message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. Analogue addressable multisensor detector with talking indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s iv) Bell, 800Hz Analogue addressable multisensor detector with talking indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-07502 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. 4) The beacon functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with short circuit isolator LPCB Ref. No.

6000PLUS/OPHT

201u/01

6000PLUS/OPHT/S

201x/01

6000PLUS/OPHT/SX

201x/02

6000PLUS/OPHT/SL

201x/03

6000PLUS/OPHT/TS

201x/04

6000PLUS/OPHT/TSX

201x/05

6000PLUS/OPHT/TSL

201x/06

6000PLUS/OPHTCO

201y/01

12 Sep 2011

237

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) The CO functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The CO functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets rhe requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s 4) The CO functionality is not included within the scope of this approval Analogue addressable multisensor and CO detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-07502 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The CO and beacon functionality are not included within the scope of this approval Analogue addressable multisensor and CO detector with talking indoor sounder short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit. 4) The CO and beacon functionality are not included within the scope of this approval Analogue addressable multisensor and CO detector with talking indoor sounder, short circuit isolator and beacon (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases) Notes: 1) Meets the requirements of EN 54-5: 2000 at Class A2 2) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings 3) Meets the requirements of EN 54-3: 2001 with the following tones: i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s iv) Bell, 800Hz 4) The CO and beacon functionality are not included within the scope of this approval LPCB Ref. No.

6000PLUS/OPHTCO/S

201z/01

6000PLUS/OPHTCO/SX

201z/02

6000PLUS/OPHTCO/SL

201z/03

6000PLUS/OPHTCO/TSL

201z/04

6000PLUS/OPHTCO/TSLX

201z/05

Bases: 3000/BASE standard base 6000/BASE standard low profile base 6000/DIB isolator base 6000PLUS/BASE, standard mounting base 6000PLUS/FFBASE, recessed mounting base N28-075-01, Plug and Play Fast Fix base N28-075-02, Plug and Play Surface base

238

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Safex Fire Services Limited


202 Dhanraj Industrial Estate, Sun Mill Road, Lower Parel West, Mumbai-400 013, India Tel: +91-22-24938108 Fax: +91-22-24950224 E-mail: ho@safexfire.com Website: www.safexfire.com
Certificate No: 506a-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products SF-871 Bases AHMB-L mounting base Conventional photoelectric smoke detector (AHMB-L Base) LPCB Ref. No. 506a/01

Certificate No: 506b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 ,EN 54-5: 2000 + A1: 2002 , CEA 4021: 1999

Multi-Criteria Detectors
Certificated Products SF-0315-2 SF-0315-3 SF-0315-4 Bases AHMB-031 mounting base (2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) (4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) LPCB Ref. No. 506b/01 506b/02 506b/03

Sareme UAB
Naugarduko str. 32/2, Vilnius LT2006, Lithuania Tel: +3705 2135047 Fax: +3705 2333567 E-mail: valdemar@sareme.lt
Certificate No: 512d to EN 54-5: 2000

Heat Detectors
Certificated Products EA323-2 EA323-4 Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base) LPCB Ref. No. 512d/01 512d/05

Bases: P/N854001 4-Wire detector base

12 Sep 2011

239

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southhampton)


Unit 7, The Quadrangle, Abbey Park Industrial Estate, Romsey, Southampton, Hampshire SO51 9DL, United Kingdom Tel: +44 (0)23 8076 5500 Fax: +44 (0)23 8076 5501 Website: www.slb.com
Certificate No: 648a to LPCB Test Schedule 109819/1.1 Certificate No: 648b to LPCB Test Schedule E120263/1.3

Linear Heat Detection System


Certificated Products LTS200 Fibre Optic Linear Heat Detection System consisting of:- LTS200 Sensor Control Unit. - SensorTube (Part No. 00.000011) Optical Fibre sensor. The approval is conditional on the following: - The linear heat detection system is installed, configured and commissioned in accordance with the manufacturer's instructions. - The optical fibre sensor does not exceed a maximum length of 2 km and is connected in a loop configuration with the break detect option enabled. - The zone/alarm configuration parameters are set, in accordance with the manufacturer's instructions (User Manual Page 40), to give an alarm response equivalent to Class A1R specified in EN 54-5: 2000. Fibre Optic Linear Heat Detection System consisting of: - DTS240 Sensor Control Unit. - SensorTube (Part No. 00.000011) Optical Fibre sensor. The approval is conditional on the following: -The linear heat detection system is installed, configured and commissioned in accordance with the manufacturer's instructions. - The optical fibre sensor does not exceed a maximum length of 4 km and is connected in a loop configuration with the break detect option enabled. - The zone/alarm configuration parameters are set, in accordance with the manufacturer's instructions(User Manual Page 30), to give an alarm response equivalent to Class A1R specified in EN 54-5: 2000. LPCB Ref. No. 648a/01

LTS240

648b/01

SHIELD FIRE, SAFETY & SECURITY LTD


28th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United Kingdom Tel: +44 161 257 2541 Fax: +44 161 225 8817 E-mail: dorota@xportsales.com Website: www.xportsales.com
Certificate No: 548k to EN 54-12: 2002

Beam Detectors
Certificated Products D-A430/R Intelligent optical beam detector Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings: Level 1 - 1.61 dB Level 2 - 2.31dB LPCB Ref. No. 548k/01

Certificate No: 548d to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products D-C401 Conventional photoelectric smoke detector (DZ-03 base) LPCB Ref. No. 548d/01

240

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products D-A411 Bases: DZ-03 Standard detector base Certificate No: 548c to EN 54-5: 2000 Intelligent photoelectric smoke detector (DZ-03 base) LPCB Ref. No. 548d/02

Heat Detectors
Certificated Products D-C402 D-A412 Bases: DZ-03 Standard detector base Conventional Class A1R heat detector (DZ-03 base) Intelligent Class A1R heat detector (DZ-03 base) LPCB Ref. No. 548c/01 548c/02

Siemens Switzerland Limited, Building Technologies Division


International Headquarters, Fire Safety & Security Products, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 Fax: +41 (0) 41 724 35 22 Manufacturing at: Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland Tel: +41 1 922 6111 Fax: +41 1 922 6450

UK Sales: Siemens Building Technologies Limited, FSP Division Tel: +44 (0)1784 461616 Fax: +44 (0)1784 464646

Certificate No: 126x-(cl-1) to EN 54:7: 2000 + A1:2002 + A2:2006 Certificate No: 126ab-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 126am-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 Certificate No: 531c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 531d-(cl-1) to EN 54-7:2000 + A1:2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003-07 Certificate No: 531e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A1: 2006 and EN 54-17: 2005

Point Smoke Detectors


Certificated Products FDO241 FDO221 DO1131A DO1152A Analogue addressable photoelectric smoke detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Analogue addressable photoelectric smoke detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Addressable photoelectric smoke detector with short circuit isolator (DB1131A base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings Addressable photoelectric smoke detector with short circuit isolator (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1131A base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Scattered light smoke detector (Z94 base) Note: 1. Meets requirements of EN54-7 at standard (2.5%/m) and increased (1.7%/m) sensitivity setting LPCB Ref. No. 126ab/01 126ab/02 126am/03 126am/05

DOT1131A

126am/06

DOT1152A

126am/09

R970

126x/01

12 Sep 2011

241

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products DO1101A DO1101A-Ex DO1151A Conventional photoelectric smoke detector (DB1101A base) Intrinsically safe conventional photoelectric smoke detector (DB1101A base) Addressable photoelectric smoke detector (DB1151A base) Note: 1. Meets EN54-7 at Personen/life sensitivity settings Addressable photoelectric smoke detector with thermal enhancement (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Intrinsically safe addressable photoelectric smoke detector with thermal enhancement (DB1151A base) Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Conventional photoelectric smoke detector with thermal enhancement (SO320 base) Conventional photoelectric smoke detector (SO320 base) Analogue addressable photoelectric smoke detector with thermal enhancement (SO620 base) Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settings Analogue addressable photoelectric smoke detector (SO620 base) Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settings Analogue addressable photoelectric smoke detector (SO820 base) Note: Meets the requirements of EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings Analogue addressable multi sensor smoke detector (DB720, DB721 bases) Note: 1. Meets the requirements of EN 54-7 in the following sensitivities: 1 - Robust 3.5%/m 2 - Sensitive 2.5%/m Analogue addressable smoke detector with short circuit isolator (DB720, DB721 bases) Note: 1. Meets the requirements of EN 54-7 in the following sensitivities: 1 - Standard 2.5%/m 2 - Sensitive 1.8%/m Analogue addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (SO320 base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings Analogue addressable photoelectric smoke detector with short circuit isolator (SO320 base) Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings LPCB Ref. No. 126x/02 126x/03 126x/04

DOT1151A

126x/05

DOT1151A-Ex

126x/06

OH320C OP320C OH620 OP620 OP820 OH720

531c/02 531c/04 531c/05 531c/06 531c/07 531d/01

OP720

531e/01

OH320A

531e/02

OP320A

531e/03

Bases: Z94 base FDB221 base FDB201 base "Collective" FDB291 base attachment surface FDB292 base attachment surface wet DB720 Detector base DB721 Detector base with loop contact DB1101A base DB1131A base DB1151A base DBZ1191 base attachment SO620 Analogue addressable (AnalogPLUS) detector base SO820 Analogue addressable (Interactive) detector base SO320 base for SynovaTM 300 series detectors

242

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 126aa-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 126an-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 531b-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificate No: 531f-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 126av-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005

Point Heat Detectors


Certificated Products FDT241 FDT221 DT1101A DT1101A-Ex DT1102A DT1102A-Ex DT1151A-Ex DT1131A DT1152A Analogue addressable rate of rise heat detector with short circuit isolator. (FDB221, FDB201, FDB291 and FDB292 bases) Note: Meets EN 54-5: 2000 at Class A1R, A1S, BR and BS. Analogue addressable rate of rise heat detector with short circuit isolator (FDB221, FDB201, FDB291 and FDB292 bases) Note: Meets EN 54-5: 2000 at Class A1R and BR Conventional class A1R heat detector (DB1101A base) Conventional intrinsically safe class A1R heat detector (DB1101A base) Conventional class B heat detector (DB1101A base) Conventional intrinsically safe class B heat detector (DB1101A base) Analogue addressable intrinsically safe heat detector (DB1151A base) Note: Meets EN54-5: 2000 at class A1R and class B Analogue addressable class A1R heat detector with short circuit isolator (DB1131A base) Analogue addressable heat detector with short circuit isolator (DB1151A base) Note: 1. Meets EN 54-5:2000 at class A1R and class BS Conventional class A1R heat detector (SO320 base) Conventional class A2 heat detector (SO320 base) Analogue addressable (AnalogPLUS) Class A1R heat detector (SO620 base) Analogue addressable (Interactive) heat detector (SO820 base) Note: Meets the requirements of EN54-5: 2000 at class A1R and class BR Analogue addressable class A2S and A2R heat detector with short circuit isolator (DB720, DB721 bases) Notes: 1. Meets the requirements of EN 54-5 at classes A2S and A2R Analogue addressable class A2S heat detector with short circuit isolator (DB720, DB721 bases) Notes: 1. Meets the requirements of EN 54-5 at class A2S Analogue addressable class A1R heat detector with short circuit isolator (SO320 base) Analogue addressable class A2 heat detector with short circuit isolator (SO320 base) LPCB Ref. No. 126aa/01 126aa/02 126an/01 126an/02 126an/03 126an/04 126an/06 126av/01 126av/02

HI320C HI322C HI620 HI820 HI720

531b/03 531b/04 531b/05 531b/06 531f/01

HI722

531f/02

HI320A HI322A

531f/03 531f/04

Bases: Z94 base DFB1190 base FDB221 base FDB201 base Collective FDB291 base attachment surface FDB292 base attachment surface wet DB720 Detector base DB721 Detector base with loop contact DB1101A base for conventional addressing DB1131A base for analogue addressing DB1151A base for interactive fire detectors SO320 base for SynovaTM 300 series detectors SO620 Analogue addressable (AnalogPLUS) detector base SO820 Analogue addressable (Interactive) detector base

Certificate No: 126ag-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005 Certificate No: 126ak-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005

Beam Detectors
Certificated Products FDL241-9 DLO1191 Analogue addressable beam detector with short circuit isolator (FDLB291 base) Note: Certified at sensitivity settings 30%, 50% and 65% Optical beam smoke detector with short circuit isolator (DLB1191A base) LPCB Ref. No. 126ag/01 126ak/01

12 Sep 2011

243

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Note: 1. Certified at sensitivity setting 30%, 50% and 65% Bases: FDLB291 base DLB1191A base Certificate No: 126s-(cl-1) to EN 54-10: 2002 Certificate No: 126af-(cl-1) to EN 54-10: 2001 + A1: 2005 and EN 54-17: 2005 Certificate No: 126ay-(cl-1) to EN 54-10: 2002 and EN 54-17: 2005 LPCB Ref. No.

Flame Detectors
Certificated Products FDF241-9 FDF221-9 DF1192 Analogue addressable infra red flame detector with short circuit isolator (FDFB291 base) Note: 1. Meets EN 54-10: 2002 at Class 1 and 2 only Analogue addressable infra red flame detector with short circuit isolator (FDFB291 base) Note: 1. Meets EN 54-10: 2002 at Class 1 and 2 only Analogue addressable infra red flame detector with short circuit isolator (DFB1190 Base) Note: 1. Certificated in increased & standard sensitivity settings - Class 1 and 2 respectively. Analogue addressable infra red flame detector with short circuit isolator (DFB1190 Base) Note: 1. Certificated in increased & standard sensitivity settings - Class 1 and 2 respectively. Analogue addressable IS infra red flame detector with short circuit isolator (DFB1190 Base) Note: 1. Certificated in increased & standard sensitivity settings - Class 1 and 2 respectively. Conventional I.S. infra red flame detector (DFB 1190 base) Note: 1. Certificated in "increased" & "standard" sensitivity settings - Class 1 and 2 respectively. LPCB Ref. No. 126af/01 126af/02 126ay/01

DF1191

126ay/02

DF1151-Ex

126ay/03

DF1101-Ex

126s/03

Bases: Z94 base DFB 1190 base FDFB291 base Certificate No: 126ah-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005

Multi-criteria Detectors
Certificated Products FDOOT241-9 Analogue addressable multisensor detector with short circuit isolator (FDB201, FDB202, FDB221, FDB222, FDB291 and FDB293 bases) Note: Meets the requirements of EN 54-5: 2000 at Class A2R & A2S and EN 54-7: 2000 at sensitivity settings: Parameter No. 1 Universal Parameter No. 2 Robust with thermal enhancement Parameter No. 3 Sensitive Parameter No. 4 Balanced with thermal enhancement Parameter No. 5 Suppression with thermal enhancement Parameter No. 6 Response with thermal enhancement Parameter No. 7 Robust / BGD with thermal enhancement Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB222, FDB291 and FDB293 bases) Note: Meets the requirements of EN 54-5: 2000 at Class A2R & A2S and EN 54-7: 2000 at sensitivity settings: Parameter No. 2 Robust with thermal enhancement Parameter No. 4 Balanced with thermal enhancement Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB222, FDSB291 & FDSB293 bases) Note - the following modes are approved LPCB Ref. No. 126ah/01

FDOOT221

126ah/02

FDOOTC241

126ah/03

244

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Mode 0 - Neural Fire Detector: 0.0) High Compensation 0.2) Robust 0.4) Balanced 0.5) Suppression 0.6) Fast Response 0.7) High Compensation 0.9) High Sensitive Fast 0.10) Balanced CO 0.12) Suppression CO Mode 1 - Heat Detector 1.3) A1S 1.4) BS Mode 2 - Smoke Detector 2.0) Universal 2.1) Universal 2.2) Robust 2.3) Sensitive LPCB Ref. No.

Bases: FDB221 base with stand offs FDB201 base Collective with stand offs FDB202 base Collective without stand offs FDB222 base without stand offs FDB291 base attachment surface FDB292 base attachment surface wet FDB293 base attachment surface wet

SMS
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: Nikki.Morgan@honeywell.com Website: www.gent.co.uk
Certificate No: 042ak to EN 54-5: 2000 + A1: 20002, EN 54-3: 2001 + A1: 2002, CEA GEI 1-084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0,

Point Heat Detectors


Certificated Products Sen-780 S-Quad analogue addressable Class P heat detector with sounder (Sen-700 Standard base with or without Sen-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Contiuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs S-Quad analogue addressable Class P heat detector with sounder and strobe (Sen-700 Standard base with or without Sen-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Contiuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe note included in scope of approval LPCB Ref. No. 042ak/01

Sen-780-ST

042ak/03

Bases: Sen-700 standard base Sen-FLUSH semi-flush fixing kit

12 Sep 2011

245

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 042an to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002, CEA 4021: 2003-07, CEA 1-084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0 Certificate No: 042bf to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005

Multi Criteria Detectors


Certificated Products Sen-770-ST S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobe (Sen-700 Standard base with or without Sen-FLUSH semi-flush mounting kit) Notes: 1. Meets the requirement of EN 54- 5 and EN 54-7 at the following settings: State 0 - Medium optical / Class A1 heat 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe not included in scope of approval. S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector (SEN-700 base with or without SEN-FLUSH mounting kit) Note: 1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat LPCB Ref. No. 042an/06

SEN-710

042bf/01

Bases: SEN-700 standard base SEN-FLUSH Semi-flush fixing kit SEN-FLUSH Semi-flush mounting kit Certificate No: 042be to EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005 Certificate No: 042bd to EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005

Point Smoke Detectors


Certificated Products SEN-715 S-Quad analogue addressable optical smoke detector (SEN-700 base with or without SEN-FLUSH mounting kit) Note: 1. Meets the requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical S-Quad analogue addressable Class P heat detector (SEN-700 base with or without SEN-FLUSH mounting kit) Note: 1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Class A1 heat LPCB Ref. No. 042bd/01

SEN-720

042be/01

Bases: Sen-700 standard base Sen-FLUSH semi-flush fixing kit SEN-FLUSH Semi-flush mounting kit

Spectrex Inc
Peckman Industrial Park, 218 Little Falls Road, Cedar Grove, NJ 07009, United States Tel: +973 239 8389 Fax: +973 239 7614 E-mail: eric@spectrex-inc.com Website: www.spectrex-inc.com
Certificate No: 911a-(cl-1) to EN 54-10: 2002 + A1: 2005

246

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Flame Detectors
Certificated Products Sharpeye 40/40R Conventional Class 1 single IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40R-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 1 triple IR (IR3) flame detector Notes: 1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters or numbers following the standard model number outlined respectively below e.g.40/40I-abcde) a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 1 quad IR flame detector Notes: 1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40M-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4B-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40LB-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV/IR flame detector LPCB Ref. No. 911a/01

Sharpeye 40/40I

911a/02

Sharpeye 40/40M

911a/03

Sharpeye 40/40L4B

911a/04

Sharpeye 40/40L4

911a/05

Sharpeye 40/40LB

911a/06

Sharpeye 40/40L

911a/07

12 Sep 2011

247

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L-abcde): a. b. c. d. e. Sharpeye 40/40UB Wiring options - 1 to 5 Maximum operating temperature - 1=75C ; 2=85C Cable entry - 1=M25 ; 2=3/4-14NPT Housing - S=Stainless steel ; A=Aluminium Approval - C= ATEX, IECEx; F= FM, CSA 911a/08 LPCB Ref. No.

Conventional Class 2 UV flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40UB-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA Conventional Class 2 UV flame detector Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40U-abcde): a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA

40/40U

911a/09

Sterling Safety Systems


Unit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United Kingdom Tel: +44(0)1926485282 Fax: +44(0)1926485090 E-mail: info@sterlingsafety.co.uk Website: www.sterlingsafety.co.uk
Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 928d to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products HFI-TA-01 Analogue addressable Class P heat detector with short circuit isolator (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector lite (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01

HFI-TAE-01

928d/01

Bases HFI-UB-01 HFI-DUB-01 HFI-DMB-01 HFI-DDB-01 HFI-UBS-01 HFI-DUBS-01 HFI-DMBS-01

Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip

248

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
HFI-DDBS-01 Vega deep adaptor base with shorting clip

Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products HFI-PA-01 Analogue addressable photoelectric smoke detector with short circuit isolator (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector lite (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928b/01

HFI-PAE-01

928e/01

Bases HFI-UB-01 HFI-DUB-01 HFI-DMB-01 HFI-DDB-01 HFI-UBS-01 HFI-DUBS-01 HFI-DMBS-01 HFI-DDBS-01

Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip

Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003 Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Multi-Sensor Detectors
Certificated Products HFI-MA-01 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFIDMBS-01 and HFI-DDBS-01 bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928c/01

12 Sep 2011

249

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products HFI-MAE-01 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928f/01

Bases HFI-UB-01 HFI-DUB-01 HFI-DMB-01 HFI-DDB-01 HFI-UBS-01 HFI-DUBS-01 HFI-DMBS-01 HFI-DDBS-01

Universal adaptor base Deep adaptor base Vega adaptor base Vega deep adaptor base Universal adaptor base with shorting clip Deep adaptor base with shorting clip Vega adaptor base with shorting clip Vega deep adaptor base with shorting clip

System Sensor
3825 Ohio Avenue, Saint Charles, Illinois 60174, United States Tel: +1 630 377 6580 Fax: +1 630 377 7245 Website: www.systemsensor.com European Sales Enquiries: System Sensor Europe Tel: +44 (0)1403 891920 Fax: +44 (0)1403 891921

Certificate No: 118h to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products 7251 Analogue addressable photoelectric laser smoke detector (B501, B501AP, B501DG, B524IEFT, B524IEFT-1 bases) Note: meets requirements of EN 54: Part 7 at sensitivities 7 to 9 inclusive LPCB Ref. No. 118h/01

Bases: B501 analogue sensor base B501AP intelligent detector base B501DG deep base B524IEFT short circuit isolator base B524IEFT-1 short circuit isolator base

250

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

System Sensor, Honeywell International (I) PVT. Limited


Sector 36, Pace City - II, Gurgaon - 122 004, Haryana, India Tel: +91 124 6371770 Fax: +91 124 6371713 E-mail: anil.chugh@honeywell.com
Certificate No: 550a to EN 54-7: 2000 + A1 2002

Point Smoke Detectors


Certificated Products 2351E Conventional photoelectric smoke detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-7:2000 at low, medium & high sensitivity settings. Conventional photoelectric smoke detector (FL/B401 base) Notes: Meets the requirements of EN54-7 at low, medium and high sensitivity settings. Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Conventional photoelectric smoke detector (FL/1000B base) Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases) Notes : Meets EN 54-7 with low, medium and high sensitivity settings LPCB Ref. No. 550a/01

FL/2351E

550a/01

EC01003 FL/1003 2251EM

550a/02 550a/02 550a/03

Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base FL/B401 standard base FL/1000B standard base

Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7:2000 + A1: 2002 & CEA 4021: 1999

Multi Criteria Detectors


Certificated Products 2351TEM Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at Class A1R and EN54-7:2000 at low, medium & high sensitivity settings. Conventional optical/thermal detector (FL/B401 base) Notes: Meets the requirements of EN54-5 at Class A1R and EN54-7 at High, Medium and Low sensitivity settings. LPCB Ref. No. 550b/01

FL/2351TEM

550b/01

12 Sep 2011

251

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products ECO1002 Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Note: Meets the requirements of EN 54-5:2000 at class A1R at pre-set sensitivity. Conventional optical/thermal detector base) Notes: Meets the requirements of EN54-5 at class A1R at pre-set sensitivity Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1 bases) Notes : 1) Meets the requirements of EN 54-7: 2000 at sensitivity settings 1 to 5 2) Meets the requirements of EN 54-5: 2000 at Class A1R LPCB Ref. No. 550b/02

FL/1002

550b/02

2251TEM

550b/03

Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode B501 standard analogue detector base B501DG deep analogue detector base B5241EFT-1 analogue short circuit isolator base FL/B401 standard base FL/1000B standard base

Certificate No: 550c to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products 5351E Class A1R conventional rate of rise heat detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at class A1R. Conventional Class A1R rate of rise heat detector (FL/B401 base) Class BS conventional heat detector (B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases) Note: Meets the requirements of EN54-5:2000 at class BS. Conventional A1R rate-of-rise heat detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases) Conventional Class A1R rate of rise heat detector (FL/1000B base) Analogue addressable Class A1S fixed temperature heat detector (B501, B501DG and B5241EFT-1 bases) Analogue addressable Class A1R high temperature rate of rise heat detector (B501, B501DG and B5241EFT-1 bases) LPCB Ref. No. 550c/01

FL/5351E 4351E

550c/01 550c/02

ECO1005 FL/1005 5251EM 5251REM

550c/03 550c/03 550c/04 550c/05

252

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Bases: B401 standard base B401DG deep base B401R standard base with schottky diode B401SD standard base with schottky diode B401RSD standard base with 470 ohm resistor and schottky diode B401R1000 standard base with 1000 ohm resistor B401DGR deep base with 470 ohm resistor B401DGR1000 deep base with 1000 ohm resistor B401DGSD deep base with schottky diode ECO1000B standard base ECO1000BSD standard base with schottky diode ECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diode ECO1000BR680 standard base, 680 ohm resistor ECO1000BR680SD standard base, 680 ohm resistor and schottky diode ECO1000BR1000 standard base, 1000 ohm resistor ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode FL/B401 standard base FL/1000B standard base

Talentum Developments Limited


Beal Lane, Shaw, Oldham, Lancashire OL2 8PF, United Kingdom Tel: +44 (0)1706 844714 Fax: +44 (0)1706 882612 E-mail: info@talentum.co.uk Website: www.talentum.co.uk
Certificate No: 729a to EN 54-10: 2002

Flame Detectors
Certificated Products 016589 016689 016579 016679 016519 016619 016581 016681 016571 016511 016611 016591 016521 Conventional IR Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only Analogue Addressable IR 3 Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only Conventional IR 3 Intrinsically Safe Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only Analogue Addressable IR 3 Intrinsically Safe Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only Conventional IR 3 (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only Analogue Addressable IR 3 (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10:2002 at Class 1 only Conventional IR2 Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only Analogue Addressable IR2 Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR2 Intrinsically Safe Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only Conventional IR2 (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only Analogue Addressable IR2 (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR 2 Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only Conventional UV/IR 2 (Exd) Flameproof Flame Detector (007127) Note: Meets EN 54-10: 2002 at Class 1 only
3

LPCB Ref. No. 729a/01 729a/02 729a/03 729a/04 729a/05 729a/06 729a/07 729a/08 729a/09 729a/10 729a/11 729a/12 729a/13

Ancillaries 007127 Mounting Bracket

12 Sep 2011

253

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

Tamlite Emergency & Fire


Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire B98 0HU, United Kingdom Tel: +44 (0)1527 51777 Fax: +44 (0)1527 517666 E-mail: sales@tamlite.co.uk Website: www.tamlite.co.uk
Certificate No: 928d to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products FSV-RR/FH Conventional Class P, heat detector (FSV-CDB base) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B. LPCB Ref. No. 928d/02

Base FSV-CDB Universal adaptor base with resistor and Schottky diode

Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products FSV-OPT/P Conventional photo smoke detector (FSV-CDB base) LPCB Ref. No. 928e/02

Base FSV-CDB Universal adaptor base with resistor and Schottky diode

Teledata S.r.l.
Via Giulietti 8, Milan 20132, Italy Tel: +39 02-27201352 Fax: +39 02-2593704 E-mail: info@teledata-i.com Website: www.teledate-i.com
Certificate No: 928a-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005 Certificate No: 928d-(cl-6) to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products SF3500 Analogue addressable Class P heat detector with short circuit isolator (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B Analogue addressable Class P heat detector lite (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B LPCB Ref. No. 928a/01

SF3500E

928d/01

Bases BS100 BS100E BS100/S BS100E/S

Universal adaptor base Vega adaptor base Universal adaptor base with shorting clip Vega adaptor base with shorting clip

254

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificate No: 928b-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificate No: 928e-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificate No: 928f-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Point Smoke Detectors


Certificated Products SF1000 Analogue addressable photoelectric smoke detector with short circuit isolator (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable photoelectric smoke detector lite (BS100, BS100E, BS100/S and BS100E/S bases) Note: 1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite (BS100, BS100E, BS100/S and BS100E/S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No. 928b/01

SF1000E

928e/01

SF2000E

928f/01

Bases BS100 BS100E BS100/S BS100E/S

Universal adaptor base Vega adaptor base Universal adaptor base with shorting clip Vega adaptor base with shorting clip

Certificate No: 928c-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products SF2000 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (BS100, BS100E, BS100/S and BS100E/S bases) Notes: 1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response LPCB Ref. No. 928c/01

12 Sep 2011

255

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low LPCB Ref. No.

2.

3.

Bases BS100 BS100E BS100/S BS100E/S

Universal adaptor base Vega adaptor base Universal adaptor base with shorting clip Vega adaptor base with shorting clip

Thorn Security Limited, trading as Tyco Safety Products


Dunhams Lane, Letchworth SG6 1BE, United Kingdom Tel: +44 (0)1462 667700 Fax: +44 (0)1462 667777 E-mail: mashbury@tycoint.com Website: www.tycosafetyproducts-europe.com
Certificate No: 681c-(cl-1) to EN 54-5: 2000 + A1: 2002

Heat Detectors
Certificated Products 801H 601H-R 601H-F MD601Ex MD611Ex 816H 611H-F 631H-F MX Digital addressable Class P heat detector (4B and 5B bases) Note: 1. Meets EN54 Part 5 for classes A1R, A2S and CR. Conventional Class A1R heat detector (4B, 4B-D and 5B bases) Conventional Class A1S heat detector (4B, 4B-D and 5B mounting bases) Conventional intrinsically safe Class A1R rate of rise heat detector (MUBEx base, 5BEx bases) Conventional intrinsically safe Class A1S fixed temperature heat detector (MUBEx base, 5BEx base) MX Digital addressable Class P heat detector (4B and 5B bases) Note: 1. Meets EN54 Part 5 for classes A1R, A2S and CR. Conventional Class A1S fixed temperature heat detector (4B, 4B-D and 5B base) Conventional Class CS fixed temperature heat detector (4B, 4B-D and 5B base) LPCB Ref. No. 681c/01 681c/02 681c/03 681c/04 681c/05 681c/06 681c/07 681c/08

Bases: 4B 4" universal mounting base 4B-D 4" diode mounting base 5B 5 Universal mounting base 5BEX Intrinsically safe detector base MUBEx Intrinsically safe detector base

Certificate No: 681j-(cl-1) to EN 54-7: 2000 + AI: 2002 + A2: 2006 and CEA4021: 1999 Certificate No: 681q-(cl-1) to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1:2002 + A2: 2006, LPS1274 Issue 1 & CEA 4021: 2003 Certificate No: 681b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA4021: 2003 Certificate No: 681a-(cl-1) to EN 54-5: 2000 + A1: 2002 & Test Schedule 68297/29.0 Test schedule for Carbon Monoxide Fire Detectors Certificate No: 681e-(cl-1) to EN 54-5: 2000 + A1: 2002 & LPS1265 Iss.1.0

256

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Multi-criteria Detectors
Certificated Products 801CH MX Digital addressable Carbon Monoxide and Class P heat detector (4B and 5B bases) Notes: Approved with the following mode configurations:1. Carbon monoxide detector at High and Normal sensitivity 2. Rate of rise heat detector at Class A1R 3. Fixed temperature heat detector at Class A2S 4. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity 5. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity and rate of rise heat detector at Class A1R Conditions of approval: 1. The 801CH should only be installed in accordance with the manufacturers recommendations. 2. The 801CH should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning / flaming fires. 3. Refer to technical publication 17A-02-DET for limitations on the use of carbon monoxide fire detection. MX digital addressable photoelectric smoke and Class P heat detector (4B and 5B Bases) LPCB Ref. No. 681a/01

801PH

681b/01

Note: Approved with the following mode configurations:1. Optical smoke detector at High and Normal sensitivity 2. Rate of rise heat detector at Class A1R 3. Fixed temperature heat detector at Class A2S 4. Heat enhanced optical smoke detector at High and Normal sensitivity 5. Optical smoke detector using FastLogic at High and Normal sensitivity 6. Heat enhanced optical smoke detector using FastLogic at High and Normal sensitivity 601CH 601PH MR601Tex 816PH 801PC Conventional Class A1R thermally enhanced Carbon Monoxide detector (4B, 4B-D and 5B Bases) Conventional high performance photoelectric smoke detector (4B, 4B-D and 5B bases) Conventional intrinsically safe high performance photoelectric smoke detector with heat enhancement (MUBEx base, 5BEx bases) MX Digital addressable photoelectric detector with heat enhancement (4B and 5B bases) Note: 1. Meets EN54 Part 7 at Normal sensitivity Analogue addressable combined optical, heat and CO fire detector (4B, 5B and DHM-5B bases) Notes: 1. Certificated at the following modes: Mode 0 - Universal multi-criteria (smoke /heat/CO) wide spectrum fire detection with Class A2S heat detection Mode 1 - Multi-criteria (smoke /heat/CO) fire detection with high false alarm immunity with Class A2S heat detection Mode 2 - Class A1R heat detection Mode 3 - Thermally enhanced smoke detection Mode 4 - Thermally enhanced CO detection 2. Meets the requirements of LPS 1274 at modes 0 and 4, CEA 4021 and EN 54-7 at modes 0, 1 and 3, and EN 54-5 at modes 0, 1, and 2. Analogue addressable combined optical, heat and CO fire detector ( marine version) (4B, 5B and DHM-5B bases) Notes: 1. Certificated at the following modes: Mode 0 - Universal multi-criteria (smoke /heat/CO) wide spectrum fire detection with Class A2S heat detection Mode 1 - Multi-criteria (smoke /heat/CO) fire detection with high false alarm immunity with Class A2S heat detection Mode 2 - Class A1R heat detection Mode 3 - Thermally enhanced smoke detection Mode 4 - Thermally enhanced CO detection 2. Meets the requirements of LPS 1274 at modes 0 and 4, CEA 4021 and EN 54-7 at modes 0, 1 and 3, and EN 54-5 at modes 0, 1, and 2. 681e/01 681j/01 681j/02 681j/03 681q/01

811PC

681q/02

Bases: 4B 4 universal mounting base

12 Sep 2011

257

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
4B-D Diode mounting base 4B-D 4" Diode mounting base 5B 5 Universal mounting base MUB Universal mounting base MUBEx intrinsically safe detector base DHM-5B - Deck head mounting adaptor for 5" base 5BEx Intrinsically safe mounting base

Certificate No: 763a to EN 54-10: 2002 Certificate No: 681r-(cl-1) to EN 54-10: 2002 Certificate No: 018e-(cl-1) to EN 54-10: 2001+ A1:2005

Flame Detectors
Certificated Products S231i+ S231f+ S241i+ S241f+ S251i+ S251f+ S261f+ S271f+ S271i+ 601F 601FEx 801F 801FEx S231i+ S231f+ S241i+ S241f+ S251i+ S251f+ S261f+ S271i+ S271f+ Class 1, conventional 2-wire intrinsically safe IR flame detector Class 1, conventional 2-wire flame proof IR flame detector Class 1, 4-20mA intrinsically safe IR flame detector Class 1, 4-20mA flame proof IR flame detector Class 1, analogue addressable intrinsically safe IR flame detector Class 1, analogue addressable flame proof IR flame detector Class 1, relay flame proof IR flame detector Class 1, analogue addressable intrinsically safe triple IR flame detector with MX interface Class 1, analogue addressable flame proof triple IR flame detector with MX interface Conventional Class 2 flame detector (4B, 4B-D and 5B bases) Conventional Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases) MX addressable Class 2 flame detector (4B and 5B bases) MX addressable Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases) Conventional class 1 2-wire intrinsically safe IR flame detector Conventional class 1 2-wire flame proof IR flame detector 4-20mA current class 1 intrinsically safe IR flame detector 4-20mA current class 1 flame proof IR flame detector Analogue addressable class 1 intrinsically safe IR flame detector Analogue addressable class 1 flame proof IR flame detector Relay class 1 flame proof IR flame detector Analogue class 1 triple IR flame detector with MX interface Analogue class 1 flame proof triple IR flame detector with MX interface LPCB Ref. No. 018e/01 018e/02 018e/03 018e/04 018e/05 018e/06 018e/07 018e/08 018e/09 681r/01 681r/02 681r/03 681r/04 763a/01 763a/02 763a/03 763a/04 763a/05 763a/06 763a/07 763a/08 763a/09

Bases: 4B 4 standard mounting base 4B-D 4 diode mounting base 5B standard mounting base MUBEx Intrinsically safe mounting base 5BEx Intrinsically safe mounting base MUB standard mounting base 5B standard mounting base 5BI addressable isolator base

Certificate No: 681d-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke Detectors
Certificated Products 801I 601I 601P 816P MX Digital addressable ionisation smoke detector (4B and 5B bases) Note: 1. Meets EN54 Part 7 in normal and high sensitivity settings only. Conventional ionisation smoke detector (4B, 4B-D and 5B bases) Conventional optical smoke detector (4B, 4B-D and 5B bases) MX Digital addressable photoelectric detector (4B and 5B bases) Note: 1. Meets EN54 Part 7 at normal and high sensitivity LPCB Ref. No. 681d/01 681d/02 681d/03 681d/05

Bases: 4B 4" universal mounting base 4B-D Diode mounting base 5B 5 Universal mounting base

258

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

UTC Fire & Security (Africa) trading as Ziton


Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa Tel: +27 21 5066000 Fax: +27 21 5066100 Website: www.utcfireandsecurity.com UK Sales Enquiries: Tel: +44 (0)1908 281981 Fax: +44 (0)1908 282554

Point Smoke Detectors


Bases: ZP7-SB1 standard base Z6-BS1 conventional surface base Z6-BS5 conventional diode base

Multi-criteria Detectors
Bases: ZP7-SB1 standards base

UTC Fire & Security Americas Corporation, Inc.


129 North Main Street, Pittsfield, ME 04967, United States Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com European Sales: Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE, United Kingdom Tel: +44 (0)1903 711 440 Fax: +44 (0)1903 711 448 E-mail: info@estinternational.com

Point Smoke Detectors


Bases: E6-BS1 Conventional surface base ZP7-SB1 Standard base

Point Heat Detectors


Bases: E6-BS1 Conventional surface base

UTC Fire & Security BV


Kelvinstraat 7, NL-6003DH, Weert, Netherlands Tel: + 31 495 58 30 00 Fax: + 31 495 55 00 42 E-mail: Daragh.O'Donnell@fs.utc.com Website: www.utcfireandsecurity.com
Certificate No: 092p-(cl-1) to EN 54-5: 2000 + A1: 2002 Certificated Products EA20E-3 Analogue addressable Class P heat detector LPCB Ref. No. 092p/01

12 Sep 2011

259

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products (ZP7-SB1 base) (Labelled EST) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled Photain Controls) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled Plana Fabrega) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Analogue addressable Class P heat detector (ZP7-SB1 base) (Labelled Ziton) Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only. Conventional Class A1 heat detector (E6-BS1 base) (Labelled EST) Conventional Class A1 heat detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional Class A1R heat detector (E6-BS1 base) (Labelled EST) Conventional Class A1R heat detector (FSBP2000 base) (Labelled Photain Controls) Conventional Class A1R heat detector (BD-21 & BD-22 bases) (Labelled Plana Fabrega) Conventional Class A1R heat detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional Class B heat detector (E6-BS1 base) (Labelled EST) Conventional Class B heat detector (FSBP2000 base) (Labelled Photain Controls) Conventional Class B heat detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) LPCB Ref. No.

PRRPHDI2004

092p/01

T-17003

092p/01

ZP720-3

092p/01

E620-581-3 Z620-581-3 E620-582-3 PRRP2004 TV-7003 Z620-582-3 E620-771-3 PHDP2004HT Z620-771-3

092p/02 092p/02 092p/03 092p/03 092p/03 092p/03 092p/04 092p/04 092p/04

Bases ZP7-SB1 Z6-BS1 E6-BS1 BD-21 FSBP2000 Z6-BS5 BD-22 Standard base Conventional surface base Conventional surface base Conventional surface base Conventional surface base Conventional diode base Conventional diode base

Certificate No: 092n-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 Certificated Products EA10E-2 Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled EST) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled Plana Fabrega) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled Photain Controls) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable ionisation smoke detector (ZP7-SB1 base) (Labelled Ziton) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled EST) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector LPCB Ref. No. 092n/01

I-17001

092n/01

ISDI2000

092n/01

ZP710-2

092n/01

EA30E-2

092n/02

O-17002

092n/02

260

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products (ZP7-SB1 base) (Labelled Plana Fabrega) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled Photain Controls) Note: 1. Approved for use at Standard sensitivity setting only. Analogue addressable photoelectric smoke detector (ZP7-SB1 base) (Labelled Ziton) Note: 1. Approved for use at Standard sensitivity setting only. Conventional ionisation smoke detector (E6-BS1 base) (Labelled EST) Conventional ionisation smoke detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) Conventional photoelectric smoke detector (E6-BS1 base) (Labelled EST) Conventional photoelectric smoke detector (BD-21 & BD-22 bases) (Labelled Plana Fabrega) Conventional photoelectric smoke detector (FSBP2000 base) (Labelled Photain Controls) Conventional photoelectric smoke detector (Z6-BS1 & Z6-BS5 bases) (Labelled Ziton) LPCB Ref. No.

PPDI2000

092n/02

ZP730-2

092n/02

E610-3 Z610-3 E630-3 O-7002 PPDP2004 Z630-3

092n/03 092n/03 092n/04 092n/04 092n/04 092n/04

Bases ZP7-SB1 Z6-BS1 E6-BS1 BD-21 FSBP2000 Z6-BS5 BD-22 Standard base Conventional surface base Conventional surface base Conventional surface base Conventional surface base Conventional diode base Conventional diode base

Certificate No: 092k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003 Certificated Products EA32E-2 Analogue addressable combined photoelectric smoke and heat detector. (Labelled EST) (ASBE-2 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled EEC) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled Plana Fabrega) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled Photain Controls) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. Analogue addressable combined photoelectric smoke and heat detector. (Labelled Ziton) (ZP7-SB1 base) Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5. LPCB Ref. No. 092k/01

EAS707

092k/01

OT-17004

092k/01

PPDPHDI2000

092k/01

ZP732-2

092k/01

Bases ZP7-SB1 Standard base ASBE-2 Standard base

12 Sep 2011

261

PART 1: SECTION 4.1


COMMERCIAL DETECTORS

VRC Terofire Products


Lion House, Lion Street, Congleton, Cheshire CW12 4BH, United Kingdom Tel: +44 (0)1260 297578 Fax: +44 (0)1260 290078 E-mail: sales@terofire.com
Certificate No: 512d to EN 54-5: 2000

Point Heat Detectors


Certificated Products 10-0003 10-0003 Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base) LPCB Ref. No. 512d/03 512d/04

Bases: P/N854001 4-Wire detector base Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products 10-0001 Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001 base) LPCB Ref. No. 512a/02

Base P/N854001 4-Wire detector base

Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Criteria Detectors
Certificated Products 10-0002 Conventional 2 wire photoelectric smoke and heat detector with remote LED output (P/N854001 base) LPCB Ref. No. 512b/02

Base P/N854001 4-Wire detector base

Xtralis Pty Limited


4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, Australia Tel: +61 3 9936 7001, +44 (0)1442 242330 Fax: +61 3 9936 7201 E-mail: marketing-emea@xtralis.com Website: www.xtralis.com

European Operations at: Xtralis (UK) Limited, Vision House, Focus 31, Mark Road, Hemel Hempstead, Hertfordshire HP2 7BW, United Kingdom Tel: +44 (0)1442 242330 Fax: +44 (0)1442 249327

Certificate No: 305e to EN 54-20: 2006 Certificate No: 305d to EN 54-20: 2006

262

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS Aspirating Smoke Detectors
Certificated Products VESDA VLF-250-xx (VLF250-01NF*) high sensitivity aspirating smoke detector Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07208). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07209). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved configurations: - VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version - VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version - VLC-400 (VLF-400-NF*) VLC Apollo (AP) version - VLC-700 (801519.F0*) VLC Esser (EB) version - VLC-800 (VLF-800-NF*) VLC Tyco (MX) version Approved remote units with the VLC-505 VESDAnet (VN) version: - VRT-J00 Remote VLC display (with 7 relays) - VRT-K00 Remote VLC display (no relays) - VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in LPCB Ref. No. 305d/01

VESDA VLF-500-xx (VLF500-01NF*) high sensitivity aspirating smoke detector

305d/02

VESDA VLC High sensitivity aspirating smoke detector

305d/03

12 Sep 2011

263

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products accordance with the VESDA VLC product guides (10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700], 09515 [VLC-800]). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLP-012 (VLP-01200-NF*) VLP detector with Display & Programmer VLP-002 (VLP-00200-NF*) VLP detector with Display VLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs only VLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDs VLP-100 VLP detector with OEM cover Approved remote units: VRT-100 Remote Programmer VRT-200 Remote VLP Display unit (with 7 relays) VRT-300 VESDAnet socket VRT-500 Remote Relay unit (with 7 relays) VRT-600 Remote VLP Display unit (without relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLP product guide (10278). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDs VLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display Module VLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program Module VLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDs VLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display Module VLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program Module VLS-100 VLS with 7 Relays and OEM cover VLS-500 VLS with 12 Relays and OEM cover Approved Remote Units: VRT-400 Remote Scanner Display with 7 relays VRT-700 Remote Scanner Display with no relays VRT-800 Remote Scanner Display with 12 relays VRT-900 Remote Scanner Relays -12 relays VRT-E00 Remote Scanner Relays - 7 relays Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLS product guide (10279). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French LPCB Ref. No.

VESDA VLP High sensitivity aspirating smoke detector

305d/04

VESDA VLS High sensitivity aspirating smoke detector

305d/05

264

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products market. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07208). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Incorporating the following ancillary equipment: VIC-010 VESDAnet network card VIC-020 Multifunction control card VIC-030 Multifunction control card VRT-V00 Remote VLF display (with 7 relays) VRT-W00 Remote VLF display (no relays) VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07209). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels. 7. Alternative model number with suffix* as indicated, intended for French market. 8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved configurations: - VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version - VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version - VLC-400 (VLF-400-NF*) VLC Apollo (AP) version - VLC-700 (801519.F0*) VLC Esser (EB) version - VLC-800 (VLF-800-NF*) VLC Tyco (MX) version Approved remote units with the VLC-505 VESDAnet (VN) version: - VRT-J00 Remote VLC display (with 7 relays) - VRT-K00 Remote VLC display (no relays) - VRT-500 Remote relay unit (with 7 relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any 7. LPCB Ref. No.

VESDA VLF-250-xx (VLF250-01NF*) high sensitivity aspirating smoke detector

305d/06

VESDA VLF-500-xx (VLF500-01NF*) high sensitivity aspirating smoke detector

305d/07

VESDA VLC High sensitivity aspirating smoke detector

305d/08

12 Sep 2011

265

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLC product guides (10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700], 09515 [VLC-800]). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLP-012 (VLP-01200-NF*) VLP detector with Display & Programmer VLP-002 (VLP-00200-NF*) VLP detector with Display VLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs only VLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDs VLP-100 VLP detector with OEM cover Approved remote units: VRT-100 Remote Programmer VRT-200 Remote VLP Display unit (with 7 relays) VRT-300 VESDAnet socket VRT-500 Remote Relay unit (with 7 relays) VRT-600 Remote VLP Display unit (without relays) Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLP product guide (10278). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed. Approved Configurations: VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDs VLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display Module VLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program Module VLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDs VLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display Module VLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program Module VLS-100 VLS with 7 Relays and OEM cover VLS-500 VLS with 12 Relays and OEM cover Approved Remote Units: VRT-400 Remote Scanner Display with 7 relays VRT-700 Remote Scanner Display with no relays VRT-800 Remote Scanner Display with 12 relays VRT-900 Remote Scanner Relays -12 relays VRT-E00 Remote Scanner Relays - 7 relays Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2. The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3. System design, installation and commissioning shall be performed in accordance with the VESDA VLS product guide (10279). 4. Remote display, programmer and relay modules are also approved in a 19 sub rack. 5. The detector is also approved when used with in-line filter models, LPCB Ref. No.

VESDA VLP High sensitivity aspirating smoke detector

305d/09

VESDA VLS High sensitivity aspirating smoke detector

305d/10

266

12 Sep 2011

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. Alternative model numbers with suffix* as indicated, intended for French market. 7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed Xtralis Class C aspirating smoke detector LPCB Ref. No.

XCC-010

305e/01

Notes: 1.

2. 3. 4.

5.

For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming with the requirements of EN 54-4. System design, installation and commissioning shall be performed In accordance with the Xtralis Class C product guide (Document 14159). The device is approved for sensitivity Class C. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

Accessories: E700-FILASSY VSP-850 In line filter In line filter

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 010v to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors


Certificated Products 80-020 Fyreye FEO2000 80-120 Fyreye FEAO2000 Conventional optical smoke detector (80-50, 80-052, 80-054 mounting bases) Analogue addressable optical smoke detector (80-50, 80-080, 80-090 mounting bases) LPCB Ref. No. 010v/01 010v/02

Bases: 80-050 FE CB Common mounting base 80-052 FE DB Diode mounting base 80-054 FE RB Relay mounting base 80-080 FEA RB Addressable relay mounting base 80-090 FE IB Negative switching isolating base Certificate No: 010u to EN 54-5: 2000 + A1: 2002

Point Heat Detectors


Certificated Products 80-030 Fyreye FEHR2000 80-032 Fyreye FEHBR2000 80-040 Fyreye FEFH2000 80-130 Fryeye FEAH2000 Conventional Class A1R heat detector (80-50, 80-052, 80-054 mounting bases) Conventional Class BR heat detector (80-050,80-052,80-054 mounting bases) Conventional Class C heat detector (80-50, 80-052, 80-054 mounting bases) Analogue addressable Class A2S heat detector (80-50, 80-080, 80-090 mounting bases) LPCB Ref. No. 010u/01 010u/02 010u/03 010u/04

12 Sep 2011

267

PART 1: SECTION 4.1


COMMERCIAL DETECTORS
Certificated Products 80-131 Fyreye FEAHH2000 Analogue addressable Class CS heat detector (80-50, 80-080, 80-090 mounting bases) LPCB Ref. No. 010u/05

Bases: 80-050 FE CB Common mounting base 80-052 FE DB Diode mounting base 80-054 FE RB Relay mounting base 80-080 FEA RB Addressable relay mounting base 80-090 FE IB Negative switching isolating base

268

12 Sep 2011

PART 1: SECTION 4.2


DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE Statistics show that Government initiatives which have increased the amount of self-contained smoke alarms fitted in domestic dwellings have had a significant impact in reducing the amount of deaths and injuries caused by fire in the UK. Section 1: Fire detection and fire alarm systems of the Building Regulations 2000, Document B1 Fire Safety in Dwellings states that All new dwelling houses shall be provided with a fire detection and fire alarm system in accordance with the relevant recommendations of BS 5839-6: 2004 to at least a Grade D, Category LD3 standard BS 5839-6: 2004 Grade D requires a system of one or more mains-powered smoke alarms each with an integral standby supply (i.e. battery back-up). The system may in addition incorporate one or more mainspowered heat alarms, each with an integral standby supply. LPCBs list of approved products in this section is intended to help you select equipment that complies with these regulatory requirements. The initial approval and continued approval processes of these types of detectors are outlined in scheme document SD078. Products listed in this section have been approved to: BS 5446-1: 2000 Fire detection and fire alarm devices for dwellings Part 1 Specification for smoke alarms BS 5446-2: 2003 Fire detection and fire alarm devices for dwellings Part 2 Specification for heat alarms BS 5446-3: 2005 Specification for smoke alarm kits for deaf and hard of hearing people EN 14604: 2005 Smoke alarm devices EN 50291: 2001 Carbon monoxide detectors (electrical) in domestic premises For domestic applications, care needs to be taken over the correct choice of the type of detector, its siting and the condition of batteries in order to maintain the alarm in accordance with the manufacturers requirements. Further guidance is available from LPCB if required. Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Note: 1. EN 14604: 2005 supersedes BS 5446-1: 2000 which was withdrawn in July 2008. Information concerning the date of withdrawal of conflicting standards in the foreword to EN 14604: 2005 is incorrect. The correct data is given in the Foreword to the UK version of BS EN 14604: 2005 and gives the date of withdrawal of BS 5446:1: 2000 as July 2008. However, EN 14604: 2005 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 August 2008. It is therefore recommended that detectors are certificated to EN 14604: 2005 as soon as possible.

Digital Security Controls, a Division of Tyco Safety Products Canada Ltd


3301 Langstaff Road, Concord, ON L4K 4L2, Canada Tel: (001) 905 760 3000 Fax: (001) 905 760 3020 E-mail: dnita@dsc.com Website: www.dsc.com
Certificate No: 1018a to EN 50291: 2001 Certificated Products WS4913 Type B battery operated carbon monoxide alarm with integral 433.92MHz RF transmitter. LPCB Ref. No. 1018a/01

Notes: 1) The functionality of the RF link is excluded from the scope of the certification. WS8913 Type B battery operated carbon monoxide alarm with Integral 868.35MHz RF transmitter. 1018a/02

12 Sep 2011

269

PART 1: SECTION 4.2


DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE
Certificated Products Notes: 1) The functionality of the RF link is excluded from the scope of the certification. LPCB Ref. No.

Eyston Company Ltd


27 Zhen Tian South Road, Wei Xing Industrial Zone, Yan Tian, Feng Gang, Dongguan, Guangdong, China Tel: +852 25573135 Fax: +852 28970249 E-mail: tracylo@eyston.com Website: www.eyston.com
Certificate No: 679a to BS 5446-1: 2000

Smoke Alarms
Certificated Products SD-176H SD-196H SD-170H SD-1982 SD-1782 Battery operated ionisation smoke alarm with alarm silence feature Battery operated photoelectric smoke alarm with alarm silence feature Battery operated ionization smoke alarm 9v battery operated photoelectric smoke alarm with alarm silence feature 9v battery operated ionisation smoke alarm with alarm silence feature LPCB Ref. No. 679a/01 679a/02 679a/03 679a/04 679a/05

Certificate No: 679b to EN 14604: 2005

Smoke Alarm
Certificated Products SD-176H SD-170H SD-1982 SD-1782 SD-196H Battery operated ionisation smoke alarm with alarm silence feature Battery operated ionisation smoke alarm 9V Battery operated photoelectric smoke alarm with alarm silence feature 9V Battery operated ionisation smoke alarm with alarm silence feature Battery operated photoelectric smoke alarm with alarm silence feature LPCB Ref. No. 679b/01 679b/02 679b/03 679b/04 679b/05

FireAngel Ltd (A Division of Sprue Aegis plc)


Vanguard Centre, Sir William Lyons Road, Coventry CV4 7EZ, United Kingdom Tel: +44 (0)2476 323232 Fax: +44 (0)2476 693610 E-mail: info@fireangel.co.uk Website: www.fireangel.co.uk
Certificate No: 651c to EN 50291: 2001

Carbon Monoxide Alarms


Certificated Products CO-828 CO-808 CO-808S Carbon Monoxide Alarm - LCD Carbon Monoxide Alarm - LED Sealed Carbon Monoxide Alarm - Dual LED LPCB Ref. No. 651c/01 651c/02 651c/03

Certificate No: 651d to EN 14604: 2005

Smoke Alarms
Certificated Products SI 601 SI 610 WSI 601 SO 601 SO 610 Battery operated ionisation smoke alarm Sealed Battery operated ionisation smoke alarm Battery operated ionisation smoke alarm with RF transmitter module Note: The RF transmitter module is not covered within the scope of this approval Battery operated optical smoke alarm Sealed Battery operated optical smoke alarm LPCB Ref. No. 651d/01 651d/02 651d/03 651d/04 651d/05

270

12 Sep 2011

PART 1: SECTION 4.2


DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE
Certificated Products WSO 601 WSO 610 Battery operated optical smoke alarm - with RF transmitter module Note: The RF transmitter module is not covered within the scope of this approval. Sealed Battery operated optical smoke alarm - with RF transmitter module Note: The RF transmitter module is not covered within the scope of this approval LPCB Ref. No. 651d/06 651d/09

Fireblitz Extinguisher Ltd


Units 15/17 Manford Industrial Estate, Manor Road, Erith, Kent DA8 2AJ, United Kingdom Tel: +44 (0)1322 342238 Fax: +44 (0)1322 331532 E-mail: sales@fireblitz.co.uk Website: www.fireblitz.co.uk
Certificate No: 971a-(cl-2) to EN 14604: 2005

Smoke Alarms
Certificated Products FireHawk FHB10 FireHawk FHB10i 10 year batteryphotoelectric smoke alarm 10 year batteryphotoelectric smoke alarm with interlink LPCB Ref. No. 971a/01 971a/02

Gira Giersiepen Gmbh & Co. KG


DahlienstraBe, D-42461 Radevormwald, Germany Tel: +49 (2195) 602-0 Fax: +49 (2195) 602-339 E-mail: info@gira.de Website: www.gira.de
Certificate No: 1025a-(cl-1) to EN 14604: 2005

Smoke Alarms
Certificated Products 2330 02 2334 02 Battery operated photoelectric smoke alarm (replaceable battery) Note: 1. The radio link functionality is not included within the scope of approval Mains operated photoelectric smoke alarm Note: 1. The radio link functionality is not included within the scope of approval LPCB Ref. No. 1025a/01 1025a/02

Kidde Finland Oy
Tiilenpolttajankuja 6, 01720 Vantaa, Finland Tel: +358 9 615 87 235 Fax: +358 9 615 87 285 E-mail: antti.soininen@kidde.fi Website: www.kidde.fi
Certificate No: 904a-(cl-2) to EN 14604:2005

Smoke Alarm
Certificated Products 0914N 0915N 0916N 0918N Replaceable 9V Battery operated ionization smoke alarm Replaceable 9V Battery operated ionization smoke alarm Replaceable 9V Battery operated ionization smoke alarm with alarm silence feature Replaceable 9V Battery operated ionization smoke alarm with alarm silence feature LPCB Ref. No. 904a/02 904a/03 904a/04 904a/05

12 Sep 2011

271

PART 1: SECTION 4.2


DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

Kidde Safety Europe Ltd


Mathison Way, Poyle Road, Colnbrook, Berkshire SL3 0HB, United Kingdom Tel: 01753 685148 Fax: 01753 685096 E-mail: Simon.Jones@kiddesafety.co.uk Website: www.kiddesafetyeurope.co.uk
Certificate No: 904a-(cl-1) to EN 14604: 2005

Domestic Alarms
Certificated Products 0910UK 0914UK 0914UK (Fire Sentry) 0915UK 0916UK 0918UK i9040EU i9060EU i9080EU 9V Battery operated ionization smoke alarm Replaceable 9V Battery operated ionization smoke alarm Replaceable 9V Battery operated ionization smoke alarm Replaceable 9V Battery operated ionization smoke alarm Replaceable 9V Battery operation ionization smoke alarm with alarm silence feature Replaceable 9V Battery operated ionization smoke alarm with emergency light and alarm silence feature Replaceable 9V Battery operated ionization smoke alarm with alarm silence feature Replaceable 9V Battery operated ionization smoke alarm with alarm silence feature Replaceable 9V Battery operated ionization smoke alarm with emergency light and alarm silence feature LPCB Ref. No. 904a/01 904a/02 904a/02 904a/03 904a/04 904a/05 904a/06 904a/07 904a/08

Ningbo Siterwell Electronics Co., Ltd.


A Zone, Hongtang Industrial Park, Hongfa Road, Hongtang Street, Jangbei District 315013, China Tel: 0086-574-8307 6656 Fax: 0086-574-8307 6652 E-mail: sales@china-siter.com
Certificate No: 1044a to EN 14604: 2005 Certificated Products GS505 GS506 GS503 Battery operated photoelectric smoke alarm Battery operated photoelectric smoke alarm Battery operated photoelectric smoke alarm (replaceable battery) (replaceable battery) (replaceable battery) LPCB Ref. No. 1044a/01 1044a/02 1044a/03

Visonic
24 Habarzel Street, Tel Aviv 69710, Israel Tel: +44 (0)870 7300810 Fax: +44 (0)870 7300801 E-mail: DalitS@visonic.com Website: www.visonic.com
Certificate No: 512e to EN 50291: 2001

Carbon Monoxide Alarms


Certificated Products MCT-442 Type A battery operated carbon monoxide alarm LPCB Ref. No. 512e/01

272

12 Sep 2011

PART 1: SECTION 4.2


DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

Weckx Handelsonderneming
Stalbergweg 55, 5913 BJ Venlo, Netherlands Tel: +31 (0)77 3512776 Fax: +31 (0)77 3547959 E-mail: info@weckx.nl Website: http://www.weckx.nl
Certificate No: 971a-(cl-3) to EN 14604: 2005 Certificated Products W-Save WS10 W-Save WS10i 10 year battery operated photoelectric smoke alarm 10 year battery operated photoelectric smoke alarm with interlink LPCB Ref. No. 971a/01 971a/02

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 330j to EN 14604: 2005 Certificated Products ZD-SI-601 ZD-SI-610 ZD-SO-601 ZD-SO-610 Battery operated ionisation smoke alarm Battery operated ionisation smoke alarm Battery operated optical smoke alarm Battery operated optical smoke alarm LPCB Ref. No. 330j/01 330j/02 330j/03 330j/04

12 Sep 2011

273

PART 1: SECTION 5
MANUAL CALL POINTS The purpose of a manual call point is to enable a person discovering a fire to initiate the operation of a fire alarm system so that appropriate measures can be taken. Therefore it is important for the manual call point to be recognizable and simple to use. For this reason, the European standard has attempted to standardised their appearance and function. There are basically two types of manual call points which are related to the method of operation. - Type A: direct operation (single action). - Type B: indirect operation (double action). Both types require the breaking or the visible displacement by change of position of a frangible element forming part of the front face. Guidance on the selection, siting and speed of response should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). For example BS 5839-1 recommends only type A with a speed of evacuation signal within 3 seconds. Other codes of practice, may require a type B installation. This section lists manual call points approved for use in fire detection and fire alarm systems in buildings. The initial approval and continued approval processes for manual call points are outlined in scheme document SD041. Products listed in this section have been approved to: EN 54-11: 2001 Manual call points EN 54-11: 2001 + A1: 2005 Manual call points ISO 7240-11: 2005 Manual call points Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-11: 2001 supersedes BS 5839-2: 1983 which was withdrawn in November 2003. EN 54-11: 2001 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 September 2008. 2. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Advanced Electronics Limited


34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0) 1226 737 465 Fax: +44 (0) 1226 737 469 E-mail: ithompson@advel.co.uk Website: www.Advel.co.uk
Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005 Certificate No: 928h-(cl-5) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products 58100-908 ADV 20-VCP100-ADV Analogue addressable manual call point with short circuit isolator and surface mounting box. Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 010w/03 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

274

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS

Advantronic Systems S.L.


C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, Spain Tel: +34 91 806 2343 Fax: +34 91 803 1171 E-mail: jpedrouzo@advantronic.es Website: www.advantronic.es
Certificate No: 928h-(cl-3) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products AV111AL Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

AMPAC Technologies PTY Ltd


7 Ledgar Road, Balcatta 6021, Australia Tel: +618 (9242) 3333 Fax: +618 (9242) 3334 E-mail: info@ampac.net Website: www.ampac.net
Certificate No: 010n to EN 54-11:2001 Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005 Certificated Products 213-0050 213-0052 213-0051 213-0053 Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box LPCB Ref. No. 010n/02 010n/06 010w/01 010w/03

12 Sep 2011

275

PART 1: SECTION 5
MANUAL CALL POINTS

Apollo Fire Detectors Limited


36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 Fax: +44 (0)2392 492754 E-mail: enquiries@apollo-fire.co.uk Sales Enquiries Germany, Apollo Deutschland GmbH Tel: +49 5241 330 60 Fax: +49 5241 330 629 E-mail: info@apollo-feuer.de

Sales Enquiries Spain, Apollo Espana Tel: +34 627 988 061 Fax: +34 949 335 289 E-mail: apollo.espana@apollo-fire.com

Sales Enquiries, China Apollo Fire Detectors Limited, Shanghai representative office Tel: +86 21 5237 0922 Fax: +86 21 5237 0920 E-mail: tony.ye@apollo-fire.com

Certificate No: 010d to BS 5839: Part 2:1983 Certificate No: 010n to EN 54-11: 2001 Certificate No: 010w to EN 54-11: 2001 and EN 54-17: 2005 Certificated Products 55000-900 XP95 55000-940 XP95 IS 55000-950 XP95 58000-900 Discovery 58000-910 Discovery 58000-920 Discovery 59000-910 XPlorer 55100-905 XP95 58100-910 Discovery 55100-908 XP95 58100-908 Discovery 58100-905 Discovery 58100-950 Discovery 55100-940 XP95IS 58100-951 Discovery Analogue addressable flush and surface mounted manual call point Certificated with Apollo, Series 90 and XP95 communication protocols Analogue addressable intrinsically safe manual call point Certificated with Apollo, Series 90 and XP95 communication protocols Analogue addressable waterproof manual call point Certificated with Apollo, Series 90 and XP95 communication protocols Analogue addressable flush and surface mounted manual call point Certificated with Series 90, XP95 and Discovery digital communication protocols Analogue addressable flush mounted manual call point Certificated with Series 90, XP95 and Discovery digital communication protocols Analogue addressable surface mounted manual call point Certificated with Series 90, XP95 and Discovery digital communication protocols Analogue addressable surface mounted manual call point Certificated with Series 90 and XP95 digital communication protocols Certificated with the Burgess V3NCSET7 Mk 1 microswitch Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box Analogue addressable manual call point with short circuit isolator, glass frangible element and surface mounting box Analogue addressable waterproof manual call point Analogue addressable intrinsically safe manual call point. Analogue addressable waterproof manual call point with short circuit isolator LPCB Ref. No. 010d/06 010d/03 010d/04 010d/05 010d/05 010d/05 010n/01 010n/02 010n/06 010w/01 010w/03 010w/05 010n/08 010n/09 010w/06

276

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS

Argus Security S.r.l.


Via Josip Ressel 2/7, S Dorligo della Valle, 34018 Trieste, Italy Tel: +39 (0) 402821110 Fax: +39 (0) 402823483 E-mail: dcresseri@argussecurity.it Website: www.argussecurity.it
Certificate No: 928h to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005

Manual Call Points


Certificated Products VCP100 Analogue addressable Type A re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

Argus-Spectrum Co
65 Serdobolskaya St, St. Petersburg 197342, Russian Federation Tel: +7 812 7037500 Fax: +7 812 7037501 E-mail: mail@argus-spectr.ru Website: www.argus-spectr.ru
Certificate No: 928h-(cl-2) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products VCP100 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

ATEIS Middle East FZCO


LIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab Emirates Tel: +971 4 6091325 Fax: +971 4 6091326 E-mail: info@ateis.ae Website: www.ateis.ae
Certificate No: 928h-(cl-10) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificated Products VELOX VCP100 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

12 Sep 2011

277

PART 1: SECTION 5
MANUAL CALL POINTS

Bentel Security s.r.l.


Via Gabbiano, n.22, Z.Ind. Le S.Scolastica, Corropoli, Teramo 64013, Italy Tel: +39 0861 839060 Fax: +39 0861 839065 E-mail: info@bentelsecurity.com Website: www.bentelsecurity.com
Certificate No: 681n to EN 54-11: 2001 + A1: 2005 Certificated Products FC420CP FC421CP Addressable Type A indoor manual call point Addressable Type A outdoor manual call point LPCB Ref. No. 681n/01 681n/02

Ceasefire Industries Ltd


"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, India Tel: +91 -22-22854677, 22854678 Fax: +91-22-66349069 E-mail: response@ceasefire.in Website: www.ceasefire.in
Certificate No: 166b-(cl-1) to EN54-11: 2001 + A1: 2005 Certificate No: 164j-(cl-1) to EN54-11:2001 Certificated Products MCP1A-R470SF-H029-02 HCP-E Indoor surface/flush mounting conventional call point Addressable Manual Call Point (SR and SR1T mounting boxes) LPCB Ref. No. 166b/39 164j/01

Accessories: SR SR1T SR2T SR3T SR4T MR ETT L BZR/1 BZR/2 BZR/3 M141 PTR C

Surface mounting plastic box Surface mounting plastic box c/w 1 terminal Surface mounting plastic box c/w 2 terminals Surface mounting plastic box c/w 3 terminals Surface mounting plastic box c/w 4 terminals Surface mounting metal box European Terminal Tray ETT1, 2 & 3 Earth Continuity Link Bezel Type 1 Bezel Type 2 Bezel Type 3 Spacer Piece Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE Hinged Cover(1)

Note: The hinged cover is optionally indicated by the presence of C at the end of the model number.

Context Plus Ltd


Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom Tel: +44 (0)161 257 2541 Fax: +44 (0)161 225 8817 E-mail: xportsales@xportsales.com Website: www.xportsales.com
Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005 Certificated Products 55100-908 IMC Analogue addressable manual call point with short circuit isolator and surface mounting box. LPCB Ref. No. 010w/01

278

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS

Cooper Fulleon Limited


Llantarnam Park, Cwmbran, South Wales NP44 3AW, United Kingdom Tel: +44 (0)1633 628500 Fax: +44 (0)1633 866346 E-mail: sales@fulleon.co.uk Website: www.cooperfulleon.com
Certificate No: 378c to EN 54: Part 11: 2001 Certificated Products CX/G/R/BB CX/P/R/NB CX/P/R/BB CXL/GP/R/BB CXL/GP/R/NB CXL/GP/R/WP CXL/GP/R/BB CXL/GP/R/NB CXL/GP/R/WP CXL/GP/R/BB/HE CXL/GP/R/WP/HE Conventional re-settable indoor manual call point, with surface mount back box* Conventional indoor manual call point, flush mounted* Conventional indoor manual call point, with surface mount back box* Conventional type A glass or plastic re-settable indoor manual call point, with surface mount back box Conventional type A glass or plastic re-settable indoor manual call point, flush mounted Conventional type A glass or plastic re-settable indoor/outdoor manual call point Conventional type A glass or plastic re-settable indoor manual call point, with surface mount back box Conventional type A glass or plastic re-settable indoor manual call point, flush mounted Conventional type A glass or plastic re-settable indoor/outdoor manual call point Conventional Type A glass or plastic re-settable indoor manual call point with Chinese text Conventional Type A glass or plastic re-settable indoor / outdoor manual call point with Chinese text LPCB Ref. No. 378c/01 378c/02 378c/02 378c/03 378c/03 378c/04 378c/05 378c/05 378c/06 378c/07 378c/08

* Approved with V4NCSET7 Mk1 or V4NSET7-UL micro switches only. Accessories: /BB surface mounted (plastic back box)

Cooper Industries Inc


Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 303303 Fax: +44 (0)1302 367155 E-mail: sales@cooper-ls.com Website: www.cooper-ls.com
Certificate No: 378d-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificate No: 378d-(cl-2) to EN 54-11: 2001 and EN 54-17: 2005 Certificated Products CBG 370S CBG 370 PAJ3034900 CBG 370WP PAJ3035100 CBG 370S-O CBG 370-O CBG 370WP-O FXN501 FXN503 MBG813 MBG814 MBG817 FXN502 Addressable type A glass indoor manual call point, with surface mount back box Addressable type A glass indoor manual call point, flush mounted Addressable type A plastic re-settable indoor manual call point with surface mount back box Addressable weatherproof type A glass indoor/outdoor manual call point Addressable weatherproof type A plastic re-settable indoor/outdoor manual call point Addressable type A glass indoor manual call point, with surface mount back box Addressable type A glass indoor manual call point, flush mounted Addressable weatherproof type A glass indoor/outdoor manual call point Addressable type A glass indoor manual call point, with surface mount back box Addressable weatherproof type A glass indoor/outdoor manual call point Addressable type A glass indoor manual call point, with surface mount back box Addressable type A glass indoor manual call point, flush mounted Addressable weatherproof type A glass indoor/outdoor manual call point Addressable type A glass indoor manual call point, flush mounted LPCB Ref. No. 378d/05 378d/06 378d/07 378d/08 378d/09 378d/12 378d/13 378d/14 378d/05 378d/08 378d/05 378d/06 378d/08 378d/06

12 Sep 2011

279

PART 1: SECTION 5
MANUAL CALL POINTS

EMCO
125 El Alamean Street, El Mohandessin, Cairo, Egypt Tel: 00202 33 44 3 245 Fax: 00202 330 36 86 0 E-mail: emco@4emco.com Website: www.4emco.com
Certificate No: 928h to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005 Certificated Products ACP200 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

Emergi-Lite Safety Systems (Thomas & Betts Ltd)


Bruntcliffe Lane, Morley, Leeds LS27 9LL, United Kingdom Tel: +44 (0)113 2810600 Fax: +44 (0)113 2810601 Website: www.emergi-lite.co.uk
Certificate No: 010n to EN 54-11:2001 Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005 Certificated Products FA95-400 FADY-400-ISO Analogue addressable manual call point with surface mounting box Analogue addressable manual call point with short circuit isolator and surface mounting box LPCB Ref. No. 010n/02 010w/03

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)


P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates Tel: +971 6 5340300 Fax: +971 6 5340090 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 506d to EN 54-11: 2001 Certificated Products FX-0217 Conventional indoor surface/flush mounting manual call point Note: Approved for surface mount use when used with the AHMB-0217 back box LPCB Ref. No. 506d/01

Accessories: AHMB-0217 back box for surface mounting

Everday Technology Co. Limited


No,.95., Sec. 2., Ligong 1 St. Road., Letzer Industrial Park, Yilan County 26841, Taiwan ROC Tel: +886 3 990 6099 Fax: +862 3 990 6029 E-mail: sales@everday.com Website: sales.everday@everday.com
Certificate No: 512f to EN 54-11: 2001 + A1: 2005

280

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS Manual Call Points
Certificated Products EM921 EM921-F EM921-TC EM921-FTC Accessories: EM921B1 EM921B2 EM921B3 Conventional manual call point with LED Conventional manual call point with flashy LED Convetnional manual call point with LED and transparent cover Conventional manual call point with flashy LED and transparent cover LPCB Ref. No. 512f/01 512f/02 512f/03 512f/04

Regular mounting base, 28mm High mounting base, 40mm High mounting base, 55m

Fireguard Safety Equipment Co Ltd


2nd Floor, 145-147 St John Street, London EC1V 4PY, United Kingdom Tel: +44 (0)8450 751042 Fax: +44 (0)8450 751043 E-mail: info@fireguard-uk.com Website: www.fireguard-uk.com
Certificate No: 512f-(cl-1) to EN 54-11: 2001 + A1: 2005 Certificate No: 928h-(cl-8) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificated Products Fireguard FG921-FTC FGCP100 Conventional manual call point with flashy LED and transparent cover Analogue addressable Type A resettable indoor manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 512f/04 928h/01

Accessories: Fireguard FG921B1 Regular mounting base, 28mm Fireguard FG921B2 High mounting base, 40mm Fireguard FG921B3 High mounting base, 55m Ancillaries: SR01 Surface mounting box Flush mounting plate

Fireonica Co. Ltd


2 The Dingle, Wolverhampton WV3 9ET, United Kingdom Tel: 01902 762 163 Fax: 0845 075 1043 E-mail: info@fireguard-uk.com
Certificate No: 928h-(cl-9) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificated Products FOCP100 Analogue addressable Type A resettable indoor manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

FIREX Protection System Technology Ltd


28-38 Desborough Street, High Wycombe, Bucks, United Kingdom Tel: +44 (0)1494 601077 Fax: +44 (0)1494 601011 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 548g-(cl-3) to EN 54-11: 2001

12 Sep 2011

281

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products FX9201 FX9201I Conventional manual call point Intelligent manual call point LPCB Ref. No. 548g/01 548g/02

Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk Middle East Sales Enquiries: E-mail: gent.export@honeywell.com

Certificate No: 042aq to EN 54-11: 2001 + A1: 2005 Certificated Products S4-34800 Analogue addressable Type A indoor manual call point (S4-34895 surface mount back box) Notes: 1) Approved for use with glass non re-settable element Analogue addressable Type A indoor manual call point with protective cover (S4-34895 surface mount back box) Notes: 1) Approved for use with glass non re-settable element Analogue addressable Type A indoor manual call point (S4-34895 surface mount back box) Notes: 1) Approved for use with plastic re-settable element Analogue addressable Type A indoor manual call point with protective cover (S4-34895 surface mount back box) Notes: Approved for use with plastic re-settable element LPCB Ref. No. 042aq/01

S4-34842

042aq/02

S4-34805

042aq/05

S4-34845

042aq/06

Accessories: S4-34895 surface mount back box

Global System Technology Plc


Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United Kingdom Tel: +44 (0)1283 225 478 Fax: +44 (0)1283 222 039 E-mail: info@gst.uk.com Website: www.gst.uk.com
Certificate No: 548g-(cl-5) to EN 54-11: 2001 + A1: 2005 Certificated Products C-9202 I-9202 DC-9204 DI-9204 Conventional manual call point Intelligent manual call point Conventional re-settable indoor manual call point, surface and flush mounting (C-92FC) Digital addressable re-settable indoor manual call point, surface and flush mounting (C92FC) LPCB Ref. No. 548g/01 548g/02 548g/03 548g/04

Accessories: C-92FC Transparent Cover

282

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS

Group 4 Securicor Plc


Manor Royal, The Manor, Crawley, West Sussex RH10 9UN, United Kingdom Tel: +44 (0)20 87707000 Fax: +44 (0)20 87722531 Website: www.g4s.com
Certificate No: 548g-(cl-2) to EN 54-11: 2001 Certificated Products GS202C GS202I Conventional manual call point Intelligent manual call point LPCB Ref. No. 548g/01 548g/02

Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn
Certificate No: 548g to EN 54-11: 2001 + A1: 2005 Certificated Products J-SAF-GST9211 (E) J-SAM-GST9111 (E) DC-9204 DI-9204 Conventional manual call point Intelligent manual call point Conventional re-settable indoor manual call point, surface and flush mounting (C-92FC) Digital addressable re-settable indoor manual call point, surface and flush mounting (C92FC) LPCB Ref. No. 548g/01 548g/02 548g/03 548g/04

Accessories: C-92FC Transparent cover

HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 164j to EN 54-11:2001 Certificate No: 164r to EN 54-17: 2005, EN 54-11: 2001 + A1: 200 Certificated Products 1440270 1440300 1440380 1440360 Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) Weather Proof Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) Intelligent analogue addressable manual call point with short circuit isolator (SR mounting box) Weather Proof Intelligent analogue addressable manual call point with short circuit isolator LPCB Ref. No. 164j/01 164j/04 164r/01 164r/02

Ancillaries: SR Surface mounting plastic box - indoor models only SR1T Surface mounting plastic box c/w 1 terminal

12 Sep 2011

283

PART 1: SECTION 5
MANUAL CALL POINTS

Hochiki Europe (UK) Limited


Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 Website: www.hochikieurope.com
Certificate No: 164j to EN 54-11: 2001 + A1: 2005 Certificate No: 164r to EN 54-17: 2005, EN 54-11: 2001 + A1: 2005 Certificated Products HCP-E (HFP) HCP-EF HCP-E(DPS) HCP-W(HFP) HCP-W(DPS) SCP-DPS HCP-E HCP-W HCP-E(SCI) HCP-E(HFP)-SCI HCP-W(SCI) HCP-W(HFP)-SCI HCP-EM HCP-WM Intelligent Addressable Manual Call Point (SR and SR1T mounting boxes) Intelligent Analogue Addressable Manual Call Point - French - (SR and SR1T mounting boxes) Intelligent Analogue Addressable Manual Call Point - with Dual Pole Switching - (SR and SR1T mounting boxes) Weather Proof Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) Weather Proof Intelligent Analogue Addressable Manual Call Point with Dual Pole Switching (SR and SR1T mounting boxes) Intelligent Analogue Addressable Type A Indoor Manual Call Point Intelligent Analogue Addressable Manual Call Point (SR and SRIT mounting boxes) Weather Proof Intelligent Analogue Addressable Manual Call Point (SR and SRIT mounting boxes) Intelligent Analogue Addressable Manual Call Point with short circuit isolator (SR mounting box) Intelligent Analogue Addressable Manual Call Point with short circuit isolator (SR mounting box) Weather proof Intelligent Analogue Addressable Manual Call point with short circuit isolator Weather Proof Intelligent analogue addressable manual call point with short circuit isolator Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) Weather Proof Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) LPCB Ref. No. 164j/01 164j/02 164j/03 164j/04 164j/05 164j/06 164j/01 164j/04 164r/01 164r/01 164r/02 164r/02 164j/01 164j/04

Accessories: SR Surface mounting plastic box - indoor models only SR1T Surface mounting plastic box c/w 1 terminal

Honeywell Control Systems Ltd


Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: 01344 655609 Fax: 01344 655474 Website: www.honeywellbuildingsolutions.co.uk
Certificate No: 262p-(cl-1) to EN 54-11: 2001 + A1: 2005 Certificated Products XLS-271 Accessories KAC SR3T-P KAC ETTI-P Digital addressable indoor manual call point, surface or flush mounted. LPCB Ref. No. 262p/01

Surface mounted box Flush mounted box

284

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS

Horing LIH Industrial Co Ltd


No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC Tel: +886 2 22487599 Fax: +886 2 22407752
Certificate No: 506d to EN 54-11: 2001 Certificated Products AH-0217 Conventional indoor surface/flush mounting manual call point Note: Approved for surface mount use when used with the AHMB-0217 back box LPCB Ref. No. 506d/01

Accessories: AHMB-0217 back box for surface mounting

KAC Alarm Company Limited


KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom Tel: +44 (0)1527 406655 Fax: +44 (0)1527 406677 E-mail: sales@kac.co.uk OR marketing@kac.co.uk Website: www.kac.co.uk
Certificate No: 166b to EN 54-11: 2001 + A1: 2005 Certificated Products WR2001 WR2012 WR2004 WR2061 WR2072 WR2101 WR3001 WR3101 WR3061 WR3072 WR3631 MCP545-1 MCP545-2 MCP545-3 MCP545-4 MCP1A-Rxxxxx-yyyy-zzIS MCP1B-Rxxxxx-yyyy-zz MCP2A-Rxxxxx-yyyy-zz MCP2B-Rxxxxx-yyyy-zz MCP3A-Rxxxxx-yyyy-zz MCP4A-R000xx-yyyy-zz MCP5A-RP01wwxx-yyyyzz MCP5A-RP03wwxx-yyyyzz Indoor manual call point, flush mounted (single pole changeover). Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor manual call point, flush mounted (single pole changeover). Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor manual call point, flush mounted. Indoor surface mounting addressable manual call point Indoor flush mounting addressable manual call point Outdoor surface mounting addressable manual call point Outdoor surface mounting addressable manual call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting addressable call point Advanced Protocol (and System Sensor 500 series protocol) Indoor surface/flush mounting addressable call point Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. ww X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) 3. x G (Glass element) x F (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 6. IS indicates the intrinsically safe version. Indoor surface/flush mounting conventional call point LPCB Ref. No. 166b/01 166b/02 166b/03 166b/04 166b/05 166b/06 166b/07 166b/08 166b/09 166b/10 166b/11 166b/35 166b/36 166b/37 166b/38 166b/39 166b/40 166b/41 166b/42 166b/43 166b/44 166b/45 166b/47

MCP7A-RC01xx-yyyy-zz

166b/49

12 Sep 2011

285

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products MCP7B-RC01xx-yyyy-zz WCP1A-RxxxSx-yyyy-zz WCP1B-RxxxSx-yyyy-zz WCP2A-RxxxSx-yyyy-zz WCP2B-RxxxSx-yyyy-zz WCP3A-RxxxSx-yyyy-zz WCP4A-R000Sx-yyyy-zz WCP5A-RPwwSx-yyyy-zz WCP5A-RPwwSx-yyyy-zz Indoor surface/flush mounting conventional call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting addressable waterproof call point Advanced Protocol (and System Sensor 500 series protocol) Outdoor surface mounting addressable waterproof call point Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. S G (Glass element) S F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point IIndoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Notes: 1. XXX xx indicates the series resistor value 039 xx (lowest 39 4K7 xx (highest 4.7 k 2. xxx X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals 3. xxxx G (Glass element) xxxx F (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 6. IS indicates the intrinsically safe version. Indoor surface/flush mounting conventional call point Notes: 1. XXX xx indicates the electrical configuration ( 000 xx = no resistor, C01 xx = single pole changeover connections) 2. xxx X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals 3. xxxx G (Glass element) xxxx F (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 6. IS indicates the intrinsically safe version. Indoor surface/flush mounting conventional call point Notes: 1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) 2. x G (Glass element) x F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Notes: LPCB Ref. No. 166b/50 166b/51 166b/52 166b/53 166b/54 166b/55 166b/56 166b/57 166b/59

WCP7A-RC01Sx-yyyy-zz WCP7B-RC01Sx-yyyy-zz MCP1A-Rxxxxx-yyyy-zz MCP1B-Rxxxxx-yyyy-zzIS MCP2A-Rxxxxx-yyyy-zzIS MCP2B-Rxxxxx-yyyy-zzIS

166b/61 166b/62 166b/39 166b/40 166b/41 166b/42

MCP3A-Rxxxxx-yyyy-zzIS

166b/43

MCP4A-R000xx-yyyy-zzIS

166b/44

MCP7A-RC01xx-yyyy-zzIS MCP7B-RC01xx-yyyy-zzIS

166b/49 166b/50

286

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products 1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) 2. x G (Glass element) x F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. MCP5A-RP07xx-zz Indoor surface/flush mounting addressable call point (Labor Strauss protocol) Advanced Protocol (and Labor Strauss protocol) Notes: 1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) 2. x G (Glass element) x F (Flexible element) 3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. Outdoor surface mounting addressable call point Advanced Protocol (and Labor Strauss protocol) Notes: 2. zz (Range 0-99) indicates 1. S G (Glass element) S F (Flexible element) customer marking options detailed on KAC controlled drawing 08/2639. Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call poin Outdoor surface mounting conventional waterproof call point Notes: 1. XXX xx indicates the series resistor value 039 xx (lowest 39 4K7 xx (highest 4.7 k 2. xxxS G (Glass element) xxxS F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. Outdoor surface mounting conventional waterproof call point Notes: 1. XXX Sx indicates the electrical configuration ( 000 Sx = no resistor, C01 Sx = single pole changeover connections) 2. xxxS G (Glass element) xxxS F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 5. IS indicates the intrinsically safe version. Outdoor surface mounting conventional waterproof call point Notes: 1. S G (Glass element) S F (Flexible element) 2. yyyy (Range A000 to Z999 or STCK for standard stocked product),indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 4. IS indicates the intrinsically safe version. Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Notes: 1. S G (Glass element) S F (Flexible element) 2. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639 166b/67 LPCB Ref. No.

WCP5A-RP07Sx-zz

166b/68

WCP1A-RxxxSx-yyyy-zzIS WCP1B-RxxxSx-yyyy-zzIS WCP2A-RxxxSx-yyyy-zzIS WCP2B-RxxxSx-yyyy-zzIS

166b/51 166b/52 166b/53 166b/54

WCP3A-RxxxSx-yyyy-zzIS

166b/55

WCP4A-R000Sx-yyyy-zzIS

166b/56

WCP7A-RC01Sx-yyyy-zzIS WCP7B-RC01Sx-yyyy-zzIS

166b/61 166b/62

12 Sep 2011

287

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products 4. IS indicates the intrinsically safe version. MCP5A-RP01yz-K01301IS MCP5A-RP03yz-K01301IS Indoor surface/flush mounting addressable call point Sensor 500 series protocol) for use in intrinsically safe systems Indoor surface/flush mounting addressable call point 500 series protocol) for use in intrinsically safe systems Notes: 1. S z (Surface mounted) F z (Flush mounted) 2. y G (Glass element) y F (Flexible element) 166b/65 166b/66 LPCB Ref. No.

Accessories: SR SR1T SR2T SR3T SR4T ETT L M141W PTR C

Surface mounting plastic box(1) Surface mounting plastic box c/w 1 terminal(1) Surface mounting plastic box c/w 2 terminals(1) Surface mounting plastic box c/w 3 terminals(1) Surface mounting plastic box c/w 4 terminals(1) European Terminal Tray ETT1, 2 & 3(1) Earth Continuity Link(1) Spacer Piece(1) Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1) Hinged Cover(2) Notes: 1. The above accessories are only supplied with MCP 1-7 Series manual call points 2. The hinged cover is only supplied with the MCP & WCP Series manual call points optionally indicated by the presence of C at the end of the model number.

Certificate No: 166e to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificated Products MCP5A-RPwwxx-yyyy-zz MCP5A-RPwwxx-yyyy-zz Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol) Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol 2. ww X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) 3. x G (Glass element) x F (Flexible element) 4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol) Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol 2. S G (Glass element) S F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. Indoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and Labor Strauss protocol) Notes: 1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) LPCB Ref. No. 166e/01 166e/02

WCP5A-RPwwSx-yyyy-zz WCP5A-RPwwSx-yyyy-zz

166e/03 166e/04

MCP5A-RP08xx-zz

166e/07

288

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products 2. x G (Glass element) x F (Flexible element) 3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. Outdoor surface mounting addressable call point with short circuit isolator Advanced Protocol (and Labor Strauss protocol) Notes: 1. S G (Glass element) S F (Flexible element) 2. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639. LPCB Ref. No.

WCP5A-RP08Sx-zz

166e/08

Accessories: SR Surface mounting plastic box(1) SR1T Surface mounting plastic box c/w 1 terminal(1) SR2T Surface mounting plastic box c/w 2 terminal(1) SR3T Surface mounting plastic box c/w 3 terminal(1) SR4T Surface mounting plastic box c/w 4 terminal(1) ETT European Terminal Tray ETT 1, 2 & 3(1) L Earth Continuity Link(1) M141W Spacer Piece(1) PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1) C Hinged Cover(2) Notes: 1. The above accessories are only supplied with MCP Series manual call points 2. The hinged cover is supplied with the MCP & WCP Series manual call points optionally indicated by the present of C at the end of the model number.

Labor Strauss Sicherungsanlagenbau GmbH


Wiegelestrasse 36, A-1231 Vienna, Austria Tel: +43 1 52114-44 Fax: +43 1 52114-27 E-mail: andreas.kurzweil@lst.at Website: www.lst.at
Certificate No: 928h-(cl-6) to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005 Certificated Products FI700/MCP Analogue addressable Type A re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

MGC Systems Corp.


25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3, Canada Tel: + 905 660 4655 Fax: + 905 660 4113 E-mail: mcherubin@mircom.com Website: www.mircom.com
Certificate No: 512f to EN 54-11: 2001 + A1: 2005 Certificated Products MCP-100 Conventional manual call point with LED and transparent cover LPCB Ref. No. 512f/04

12 Sep 2011

289

PART 1: SECTION 5
MANUAL CALL POINTS

Morley-IAS Fire Systems By Honeywell


Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@morleyias.co.uk Website: www.morley-ias.co.uk
Certificate No: 166e to EN 54-11: 2001 and EN 54-17: 2005 Certificate No: 166b to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificated Products MI-MCP-xxxxx-I Indoor surface/flush mounting addressable call point with short circuit isolator. Advanced Protocol Honeywell 500 series protocol) Note: 1. xxxxx = GLASS (Glass element) or FLEX_ (Flexible element) Indoor surface/flush mounting addressable call point Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. xxxxx = GLASS (Glass element) FLEX _ (Flexible element) Outdoor surface mounting addressable waterproof call point Advanced Protocol (and Honeywell 500 series protocol) Notes: 1. Sx = S G (Glass element) S F (Flexible element) Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and Honeywell 500 series protocol) Note: 1. Sx = S G (Glass element) S F (Flexible element) Accessories: SR Surface mounting plastic box(1) SR1T Surface mounting plastic box c/w 1 terminal(1) SR2T Surface mounting plastic box c/w 2 terminal(1) SR3T Surface mounting plastic box c/w 3 terminal(1) SR4T Surface mounting plastic box c/w 4 terminal(1) ETT European Terminal Tray ETT 1, 2 & 3(1) L Earth Continuity Link(1) BZR/1 Bazel Type 1(1) BZR/2 Bazel Type 2(1) BZR/3 Bazel Type 3(1) M141W Spacer Piece(1) PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1) C Hinged Cover(2) Notes: 1. The above accessories are only supplied with MI-MCP-xxxxx & MI-MCP-xxxxx-I manual call point 2. The hinged cover may be supplied with all models and is optionally indicated by the presence of C at the end of the model number. LPCB Ref. No. 166e/02

MI-MCP-xxxxx

166b/47

MI-WCP-R/Sx

166b/59

MI-WCP-R/I/Sx

166e/04

Multron Systems Pte Ltd


217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 Fax: +65 6743 2777 / 6395 6869 E-mail: info@multron.com Website: www.multron.com
Certificate No: 548g-(cl-6) to EN 54-11: 2001 + A1: 2005 Certificated Products MCP-C204 MCP-A204 Conventional re-settable indoor manual call point, surface and flush mounting (C-92FC) Digital addressable re-settable indoor manual LPCB Ref. No. 548g/03 548g/04

290

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products call point, surface and flush mounting (C-92FC) Accessories C-92FC Transparent cover LPCB Ref. No.

Nitin Ventures FZE


P.O. Box 262294, Jabel Ali Free Zone, Dubai, United Arab Emirates Tel: +97 148865858/859 Fax: +97 148865800 E-mail: sales@nitinventures.com Website: www.nitinventures.com
Certificate No: 010w-(cl-1) to EN 54-11: 2001 and EN 54-17: 2005

Manual Call Points


Certificated Products NV-II-MCP NVI Series Manual Call Point LPCB Ref. No. 010w/03

Notifier by Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230230 Fax: +44 (0)1444 230689 E-mail: sales@notifierfiresystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 166e to EN 54-11: 2001 + A1: 2005, EN 54-17: 2005 Certificate No: 166b to EN 54-11: 2001 + A1: 2005 Certificated Products M700KACI-xx Indoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol) Notes: 1. xx = S x (Surface mounted) F x (Flush mounted) 2. xx = x G (Glass element) x F (Flexible element) 3. The above manual call point is approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G31051BBAQ) Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol) Note: 1. S x = S G (Glass Element) S F (Flexible Element) Indoor surface/flush mounting addressable call point Advanced Protocol (and System Sensor 500 series protocol) Notes: 1. xx = S x (Surface mounted) F x (Flush mounted) 2. xx = x G (Glass element) x F (Flexible element) LPCB Ref. No. 166e/01

M700WCP-R/I/Sx

166e/03

M700KAC-xx

166b/45

Accessories: SR SR1T SR2T SR3T SR4T ETT L BZR/1 BZR/2 BZR/3 M141W PTR

Surface mounting plastic box(1) Surface mounting plastic box c/w 1 terminal(1) Surface mounting plastic box c/w 2 terminal(1) Surface mounting plastic box c/w 3 terminal(1) Surface mounting plastic box c/w 4 terminal(1) European Terminal Tray ETT 1, 2 & 3(1) Earth Continuity Link(1) Bazel Type 1(1) Bazel Type 2(1) Bazel Type 3(1) Spacer Piece(1) Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1)

12 Sep 2011

291

PART 1: SECTION 5
MANUAL CALL POINTS
C Hinged Cover(2) Notes: 1. The above accessories are only supplied with M700KAC-xx & M700KACI-xx manual call points 2. The hinged cover may be supplied with all models and is optionally indicated by the precence of 'C' at the end of the model number.

OG Elektronik
Sanayi Mah., 636 Sok., Erol Apt. 11/3, Antalya, Turkey Tel: +9 0242 344 2500 Fax: +9 0242 344 2120 E-mail: info@og.com.tr; ahmet@og.com.tr Website: www.og.com.tr
Certificate No: 928h-(cl-1) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products FF VB200 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

Pelco Finland Oy
Kalkkipellontie 6, PO Box 415, Fl-02601 Espoo, Finland Tel: +358 10 446 511 Fax: +358 10 446 5103 Website: www.pelco.com/nordic
Certificate No: 010n-(cl-1) to EN 54-11: 2001 + A1: 2005 Certificated Products EPP-23E EPP-23P ESMI Intellia analogue addressable waterproof manual call point PELCO Intellia analogue addressable waterproof manual call point LPCB Ref. No. 010n/08 010n/08

Protec Fire Detection plc


Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 Fax: +44 (0)1282 717273 E-mail: sales@protec.co.uk Website: www.protec.co.uk
Certificate No: 201m to EN 54-11: 2001 Certificated Products 6000/MCP Analogue addressable indoor break glass unit LPCB Ref. No. 201m/01

Accessories: N 63-111-48 Surface mounting back box

292

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS

Safety Technology International (Europe) Limited


Unit 49G Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire B98 0HU, United Kingdom Tel: +44 (0)1527 520999 Fax: +44 (0)1527 501999 E-mail: sales@sti-europe.com Website: www.sti-europe.com
Certificate No: 653a to EN 54-11: 2001 + A1: 2005 Certificated Products Series 01 Conventional Type A re-settable indoor flush/surface mounted manual call point Notes: 1) Flush mount approved model RP-RF-01 (M200) 2) Surface mount approved model RP-RS-01 (M200 + M125) 3) Surface mount approved model RP-RS1-01 (M223) 4) Approved colour, red only LPCB Ref. No. 653a/01

Accessories M200 wall plate M125 back box M223 back box

Sareme UAB
Naugarduko str. 32/2, Vilnius LT2006, Lithuania Tel: +3705 2135047 Fax: +3705 2333567 E-mail: valdemar@sareme.lt
Certificate No: 512f to EN 54-11:2001 + A1:2005 Certificated Products SF MCP127 SF MCP127-F SF MCP127-TC SF MCP127-FTC Conventional manual call point with LED Conventional manual call point with flashy LED Conventional manual call point with LED and transparent cover Conventional manual call point with flashy LED and transparent cover LPCB Ref. No. 512f/01 512f/02 512f/03 512f/04

Accessories SF MCP127-B1 Regular mounting base, 28mm SF MCP127-B2 High mounting base, 40mm SF MCP127-B3 High mounting base, 55m

SHIELD FIRE, SAFETY & SECURITY LTD


28th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United Kingdom Tel: +44 161 257 2541 Fax: +44 161 225 8817 E-mail: dorota@xportsales.com Website: www.xportsales.com
Certificate No: 548g-(cl-4) to EN 54-11: 2001 Certificated Products BG-A450 BG-C440 Intelligent manual call point Conventional manual call point LPCB Ref. No. 548g/02 548g/01

12 Sep 2011

293

PART 1: SECTION 5
MANUAL CALL POINTS

Siemens Switzerland Limited, Building Technologies Division


International Headquarters, Fire Safety & Security Products, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 Fax: +41 (0) 41 724 35 22
Certificate No: 126w-(cl-1) to EN 54-11: 2001 + A1: 2005 Certificate No: 166b to EN 54-11: 2001 Certificate No: 126ap-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificate No: 126as to EN 54-11: 2001 + A1: 2005 Certificate No: 126ax-(cl-1) to EN 54-11: 2002 + A1: 2005 and EN 54-17: 2005 Certificated Products DM1154 Ex DM1101 MT320C DM1104 DM1104H DM1154H-Ex MT320C DM1101 FDM225-RP FDM225-RG FDM226-RP FDM226-RG FDM224 FDM224H FDM221 FDM223 FDM223H FDM225 RP (F) FDM225-RG (F) Addressable interactive manual call point Conventional indoor and outdoor manual call point Conventional indoor and outdoor manual call point Conventional indoor and outdoor manual call point Conventional indoor and outdoor manual call point (DMZ1197-AC) Addressable interactive manual call point (DMZ1197-AC) Indoor manual call point, flush mounted (single pole changeover) Indoor manual call point, flush mounted (DMZ1191 mounting box) Digital addressable Type A indoor/outdoor manual call point with resettable plastic element and incorporating a short circuit isolator (FDMH295-R and FDMH295-S) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating a short circuit isolator (FDMH295-R and FDMH295-S) Digital addressable Type A indoor/outdoor manual call point with resettable plastic element and incorporating a short circuit isolator (including housing base) Digital addressable Type A indoor/outdoor manual call point with resettable plastic element and incorporating a short circuit isolator (including housing base) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC and DMZ1195) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC and DMZ1197-AD) Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (FDMC291 and FDMK291) Digital addressable Type B indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC and DMZ1195) Digital addressable Type B indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC) Digital addressable Type A indoor/outdoor manual call point with re-settable plastic element and incorporating short circuit isolator; French labelling on re-settable plastic element (FDMH295-R and FDMH295-S) Digital addressable Type A indoor/outdoor manual call point with non-resettable glass element and incorporating a short circuit isolator; French labelling on non-resettable glass element (FDMH295-R and FDMH295-S) Collective Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element Collective Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element. Conventional Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element. Conventional Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element. Collective Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element. Collective Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element; French labelling on Resettable Plastic Element. Analogue addressable indoor and outdoor manual call point with short circuit isolator Interactive indoor and outdoor manual call point with short circuit isolator Addressable indoor and outdoor manual call point with short circuit isolator Interactive indoor and outdoor manual call point with short circuit isolator Analogue addressable indoor and outdoor manual call point with short circuit isolator (DMZ1197-AC) Interactive indoor and outdoor manual call point with short circuit isolator (DMZ1197-AC) LPCB Ref. No. 126w/01 126w/02 126w/03 126w/06 126w/09 126w/12 166b/07 166b/11 126ap/01 126ap/02 126ap/03 126ap/04 126ap/05 126ap/06 126ap/07 126ap/08 126ap/09 126ap/10 126ap/11

FDM1101-RG FDM1101-RP FDM1101A-RG FDM1101A-RP FDM1101-RG(F) FDM1101-RP(F) DM1131 DM1151 DM1134 DM1154 DM1134H DM1154H

126as/01 126as/02 126as/03 126as/04 126as/05 126as/06 126ax/01 126ax/02 126ax/03 126ax/04 126ax/05 126ax/06

Accessories: FDMC291 protective cover FDMK291 key with cover DMZ1197-AC protective cover DMZ1195 key

294

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS
DMZ1197-AD seal for wet areas Bases: FDMH295-R Housing base FDMH295-S Housing base with holes and sockets

SMS
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: Nikki.Morgan@honeywell.com Website: www.gent.co.uk
Certificate No: 042aq to EN54-11: 2001+ A1:2005 Certificated Products SEN-800 Analogue addressable Type A indoor manual call point (SEN-895 surface mount back box) Note: Approved for use with glass non re-settable element Analogue addressable Type A indoor manual call point (SEN-895 surface mount back box) Note: Approved for use with plastic re-settable element LPCB Ref. No. 042aq/01

SEN-805

042aq/05

Accessories: SEN-895 Surface mount back box 042aq

Sterling Safety Systems


Unit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United Kingdom Tel: +44(0)1926485282 Fax: +44(0)1926485090 E-mail: info@sterlingsafety.co.uk Website: www.sterlingsafety.co.uk
Certificate No: 928h to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005 Certificated Products HFI-CP-01 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

Synaps Technology Srl


Padriciano 99 c/o Area Science Park, Trieste 34012, Italy Tel: 0039 040 3755360 Fax: 0039 040 3755361 E-mail: info@synaps-technology.com Website: www.synaps-technology.com
Certificate No: 959a to EN 54-11: 2001 + A1: 2005 Certificated Products SyCALL R6847L Conventional type A indoor manual call point Ancillaries Deep back box Safety cover Wall flush mount plate (white only) and external trim frame (white only) LPCB Ref. No. 959a/01

12 Sep 2011

295

PART 1: SECTION 5
MANUAL CALL POINTS

Teledata S.r.l.
Via Giulietti 8, Milan 20132, Italy Tel: +39 02-27201352 Fax: +39 02-2593704 E-mail: info@teledata-i.com Website: www.teledate-i.com
Certificate No: 928h-(cl-7) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005 Certificated Products FDVCP100 Analogue addressable Type A resettable indoor manual call point with short circuit isolator (SR01 and Flush mounting plate) LPCB Ref. No. 928h/01

Ancillaries SR01 Surface mounting box Flush mounting plate

Thorn Security Limited, trading as Tyco Safety Products


Dunhams Lane, Letchworth SG6 1BE, United Kingdom Tel: +44 (0)1462 667700 Fax: +44 (0)1462 667777 E-mail: mashbury@tycoint.com Website: www.tycosafetyproducts-europe.com
Certificate No: 681n-(cl-1) to EN 54-11: 2001 + A1: 2005 Certificate No: 166b to EN 54-11: 2001 + A1: 2005 Certificated Products CP820 CP830 MCP200 MCP210 MCP250M MCP230 MCP260M Addressable Type A indoor manual call point Addressable Type A indoor manual call point Indoor surface/flush mounting conventional call point Indoor surface/flush mounting conventional call point Indoor/outdoor surface/flush mounting conventional call point Marine model Outdoor surface mounting conventional waterproof call point Outdoor surface mounting conventional waterproof call point Marine model LPCB Ref. No. 681n/01 681n/02 166b/41 166b/41 166b/41 166b/53 166b/53

UTC Fire & Security (Pty) LTD Trading as Ziton


Ziton House, 555 Voortrekker Road, Maitland 7405, South Africa Tel: +27 21 5066000 Fax: +27 21 5066100 Website: www.ziton.com
Certificate No: 092r to EN 54-11: 2001 + A1: 2005 Certificated Products ZP785-3 Analogue addressable manual call point Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable manual call point, Labelled Photain Controls Accessories: DMN787 Surface mounting box with earth terminal, red LPCB Ref. No. 092r/01

BGUI2000LED

092r/01

296

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable manual call point, Labelled EST Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable manual call point, Labelled Ziton Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable manual call point, Labelled Clymac Accessories: DMN787 DM790 DM795 DMN782 DMN715 DMN784 DMN800 Surface mounting box with earth terminal, red Flush mount cradle with connectors Flush mount cradle with connectors and forkgrips Hinged transparent MCP protection cover EN 54 universal MCP glass Call point test key Resettable element LPCB Ref. No.

EA785-3

092r/01

ZP785-3S-SW

092r/01

CL785-3

092r/01

UTC Fire & Security Americas Corporation, Inc.


129 North Main Street, Pittsfield, ME 04967, United States Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com European Sales: Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE, United Kingdom Tel: +44 (0)1903 711 440 Fax: +44 (0)1903 711 448 E-mail: info@estinternational.com

Certificate No: 262p to EN 54-11: 2001 Certificated Products SIGI-271 Accessories SR3T-P Surface mounted box ETT1-P Flush mounted box Digital addressable indoor manual call point, surface or flush mounted LPCB Ref. No. 262p/01

12 Sep 2011

297

PART 1: SECTION 5
MANUAL CALL POINTS

UTC Fire & Security BV


Kelvinstraat 7, NL-6003DH, Weert, Netherlands Tel: + 31 495 58 30 00 Fax: + 31 495 55 00 42 E-mail: Daragh.O'Donnell@fs.utc.com Website: www.utcfireandsecurity.com
Certificate No: 092r-(cl-3) to EN 54-11: 2001 + A1: 2005 Certificated Products ZP787-3 Outdoor analogue addressable manual call point, Labelled Ziton Accessories: DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Outdoor analogue addressable manual call point, Labelled Ziton Accessories: DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Outdoor analogue addressable manual call point, Labelled EST Accessories: DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Outdoor analogue addressable manual call point, Labelled EST Accessories: DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable indoor manual call point, Labelled Ziton Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable indoor manual call point, Labelled Photain Controls Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable indoor manual call point, Labelled EST Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable indoor manual call point, Labelled EST Accessories: LPCB Ref. No. 092r/02

ZP787-3-SW

092r/02

EA787-3

092r/02

EA787-3-18

092r/02

ZP785-3

092r/01

BGUI2000LED

092r/01

EA785-3

092r/01

EA785-3-18

092r/01

298

12 Sep 2011

PART 1: SECTION 5
MANUAL CALL POINTS
Certificated Products LPCB Ref. No. DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable indoor manual call point, Labelled Ziton Accessories: DMN787 Surface mounting box with earth terminal, red DM790 Flush mount cradle with connectors DM795 Flush mount cradle with connectors and forkgrips DMN782 Hinged transparent MCP protection cover DMN715 EN 54 universal MCP glass DMN784 Call point test key DMN800 Resettable element Analogue addressable indoor manual call point, Labelled Clymac Accessories: DMN787 DM790 DM795 DMN782 DMN715 DMN784 DMN800 Surface mounting box with earth terminal, red Flush mount cradle with connectors Flush mount cradle with connectors and forkgrips Hinged transparent MCP protection cover EN 54 universal MCP glass Call point test key Resettable element

ZP785-3S-SW

092r/01

CL785-3

092r/01

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 653a-(cl-1) to EN 54-11: 2001 + A1: 2005 Certificated Products ZT-CP3 Conventional Type A re-settable indoor flush/surface manual call point. Notes: 1. Flush mount approved model ZT-CP3/F (M200) 2. Surface mount approved model ZT-CP3 (M223) 3. Approved colour, red only LPCB Ref. No. 653a/01

Accessories M200 wall plate M223 back box

12 Sep 2011

299

PART 1: SECTION 6
LINE UNITS A Line Unit is the term given to define devices used for functions other than fire detection, which are connected to a fire detection and alarm system transmission path or within other components of the fire detection and alarm system e.g. inside Control and Indicating Equipment. For example, the following devices may be regarded as Line Units: short circuit isolators input/output interfaces

Short-circuit isolators are used to limit the consequences of low parallel resistance faults between the lines of a transmission path of a fire detection and fire alarm system. The transmission path is normally in a loop configuration which is separated into sections by the short circuit isolators, such that a detected fault in a particular section will isolate that particular section allowing other components in other sections on the loop to function correctly. Input/output devices are intended for different applications, and may therefore have different functions. Their functions are specified by the manufacturer and they are tested and approved against this specification. This section lists approved Line Units which are connected to a fire detection and alarm system. The initial approval and continued approval processes for Line Units are outlined in scheme document SD038. Products listed in this section have been approved to: EN 54-17: 2005 Short-circuit isolators EN 54-18: 2005 Input/output devices Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. It is recommended that short circuit isolators and input/output devices are certificated to EN 54-17: 2005 and EN 54-18: 2005 respectively. EN 54-17: 2005 and EN 54-18: 2005 are now harmonised standards for the Construction Products Directive and CE marking is required for most of the European market by 1 December 2008. It is therefore recommended that devices are certificated to EN 54-17: 2005 or EN 54-18: 2005 where applicable as soon as possible. 2. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

ADI International
ADI International, C/Mijancas 1, 28022 Madrid, Spain Tel: +34 91 102 5948 Fax: +34 902 550 776 E-mail: victor.gomez@adi-int.com Website: www.ademco.es
Certificate No: 199v to EN 54-17: 2005 and EN 54-18: 2005

Line Units
Certificated Products M910C Conventional zone monitor module LPCB Ref. No. 199v/07

300

12 Sep 2011

PART 1: SECTION 6
LINE UNITS

Advanced Electronics Limited


34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0) 1226 737 465 Fax: +44 (0) 1226 737 469 E-mail: ithompson@advel.co.uk Website: www.Advel.co.uk
Certificate No: 010aa to EN 54-17: 2005 Certificate No: 010ag to EN 54-18: 2005 Certificated Products 55000-802ADV 55000-182ADV 55000-803ADV 55000-822ADV DIN-Rail Mounted Dual Isolator DIN-Rail Sounder Controller (5 Amperes) DIN-Rail Mounted Input/Output Unit Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg DIN-Rail Mounted Switch Monitor LPCB Ref. No. 010aa/06 010ag/08 010ag/10 010ag/13

Apollo Fire Detectors Limited


36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 Fax: +44 (0)2392 492754 E-mail: enquiries@apollo-fire.co.uk Sales Enquiries Germany Apollo Deutschland GmbH Tel: +49 5241 330 60 Fax: +49 5241 330 629 E-mail: info@apollo-feuer.de

Sales Enquiries Spain, Apollo Espana Tel: +34 627 988 061 Fax: +34 949 335 289 E-mail: apollo.espana@apollo-fire.com

Sales Enquiries China, Apollo Fire Detectors Limited,, Shanghai representative office Tel: +86 21 5237 0922 Fax: +86 21 5237 0920 E-mail: tony.ye@apollo-fire.com

Certificate No: 010f to EFSG/F/95/007 Certificate No: 010k to CEA GEI 1-052:Draft 2: 1997 Certificate No: 010aa to EN 54-17:2005 Certificate No: 010ag to EN54-18: 2005 Certificate No: 010ah to EN54-17: 2005 & EN54-18: 2005 Certificated Products 45681-321 XP95 45681-323 XP95 55000-710 XP95 55000-720 XP95 55000-840 XP95 Negative short circuit isolating base Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Positive short circuit isolating base Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Positive short circuit isolator (45681-211 mounting base) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Negative short circuit isolator (45681-211 mounting base) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor plus with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols LPCB Ref. No. 010k/04 010k/03 010k/01 010k/02 010k/05

12 Sep 2011

301

PART 1: SECTION 6
LINE UNITS
Certificated Products 55000-841 XP95 55000-842 XP95 55000-843 XP95 55000-844 XP95 55000-845 XP95 55000-846 XP95 55000-847 XP95 55000-848 XP95 55000-849 XP95 55000-851 XP95 55000-852 XP95 55000-855 XP95 55000-856 XP95 55000-588 XP95 55000-589 XP95 45681-284 55000-875 55000-588 55000-841 55000-843 55000-845 55000-847 55000-849 55000-852 45681-321 45681-323 55000-710 55000-720 55000-802 55000-812 55000-181 55000-182 55000-821 55000-822 55000-855 55000-856 55000-760 45681-517 45681-518 45681-242 45681-245 45681-246 45681-247 45681-248 45681-508 ORB-RB-10004 ORB-SW-10005 55000-797 55000-803 55000-804 Analogue addressable switch monitor plus with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable Zone monitor unit with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable zone monitor unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable input/output unit with isolator flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable input/output unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable output unit with isolator flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable output unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable sounder controller unit with isolator -flush mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable sounder controller unit with isolator -surface mounted Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Single Channel Protocol Translator Dual Channel Protocol Translator Analogue addressable 3 Channel Input/Output unit with short circuit isolator Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable 3 Channel Input/Output unit Approved with Apollo Series 90, XP95 and Discovery digital communication protocols XP95/Discovery short circuit isolating base XP95 analogue addressable mains switch input/output unit XP95 analogue addressable 3 channel input/output unit with isolator XP95 analogue addressable switch monitor plus with isolator XP95 analogue addressable switch monitor with isolator XP95 analogue addressable zone monitor unit with isolator XP95 analogue addressable input/output unit with isolator XP95 analogue addressable output unit with isolator XP95 analogue addressable sounder controller with isolator XP95 20D negative short circuit isolating base XP95 20D positive short circuit isolating base XP95 20D positive short circuit isolator XP95 20D negative short circuit isolator XP95 analogue addressable DIN-rail dual isolator XP95 analogue addressable DIN-rail zone monitor XP95 analogue addressable DIN-rail 8A sounder controller unit XP95 analogue addressable DIN-rail sounder control unit XP95 analogue addressable DIN-rail switch monitor plus XP95 analogue addressable DIN-rail switch monitor XP95 analogue addressable DIN-rail protocol translator - single Note: to ensure compliance is maintained, all connecting cables to the protocol translator shall be less than 3m. XP95 analogue addressable DIN-rail protocol translator - dual Note: to ensure compliance is maintained, all connecting cables to the protocol translator shall be less than 3m. XP95/Discovery Analogue addressable mini switch monitor with isolator Enhanced deep isolating base (White) Enhanced deep isolating base (Red) XP95 analogue addressable low power relay base S65 conventional standard relay base S65 conventional auxiliary relay base S65 conventional end of line 12V relay base S65 conventional end of line 24V relay base S65 conventional 12V relay base Orbis TimeSaver relay base Orbis Sav-wire base XP95 analogue addressable DIN-rail mains input/output unit Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg. XP95 analogue addressable DIN-rail input/output unit Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg. XP95 analogue addressable DIN-rail output unit Note: to ensure compliance is maintained, this device shall be installed within an LPCB Ref. No. 010k/05 010k/06 010k/06 010k/10 010k/10 010k/07 010k/07 010k/08 010k/08 010k/09 010k/09 010f/01 010f/02 010k/11 010k/12 010aa/01 010ag/16 010ah/01 010ah/03 010ah/04 010ah/05 010ah/06 010ah/07 010ah/08 010aa/02 010aa/03 010aa/04 010aa/05 010aa/06 010ah/02 010ag/07 010ag/08 010ag/12 010ag/13 010ag/14 010ag/15 010ah/09 010aa/07 010aa/08 010ag/01 010ag/02 010ag/03 010ag/04 010ag/05 010ag/06 010ag/17 010ag/18 010ag/09 010ag/10 010ag/11

302

12 Sep 2011

PART 1: SECTION 6
LINE UNITS
Certificated Products enclosure weighing greater than 4.75kg. Bases: 45681-211 XP95 isolator base LPCB Ref. No.

Argus Security S.r.l.


Via Josip Ressel 2/7, S Dorligo della Valle, 34018 Trieste, Italy Tel: +39 (0) 402821110 Fax: +39 (0) 402823483 E-mail: dcresseri@argussecurity.it Website: www.argussecurity.it
Certificate No: 928n to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008 Certificated Products VW2W100 Wire to wireless translator module LPCB Ref. No. 928n/01

Autronica Fire & Security AS


Postboks 5620 NO-7483, Trondheim, Norway Tel: +47 73582500 Fax: +47 73582501 E-mail: info@autronicafire.no Website: www.autronicafire.no
Certificate No: 378g-(cl-1) to EN 54-17: 2005 Certificated Products 116-BBL-100 116-BBL-100/IP Addressable indoor beacon with isolator Notes: 1) the beacon functionality is not included within the scope of this approval Addressable outdoor beacon with isolator Notes: 1) the beacon functionality is not included within the scope of this approval LPCB Ref. No. 378g/01 378g/02

Chubb Fire Ltd


Chubb House, Staines Road West, Sunbury on Thames TW16 7AR, United Kingdom Tel: +44 (0)1932 785588 Fax: +44 (0)1932 777222 E-mail: sales@chubb.co.uk Website: www.chubb.co.uk
Certificate No: 199v to EN 54-17: 2005 and EN 54-18: 2005 Certificate No: 199x to EN 54-17: 2005 Certificated Products Resonance single input module Resonance dual input module Resonance dual input single output module Resonance single output module Resonance mains switching output module Resonance 'boxed' 240V switching output module Resonance DIN rail mount 240V mains switching Analogue addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 'boxed' 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator LPCB Ref. No. 199v/01 199v/02 199v/03 199v/04 199v/05 199v/05 199v/06

12 Sep 2011

303

PART 1: SECTION 6
LINE UNITS
Certificated Products output module Resonance conventional zone module B524IEFT-1 ISO524-1 Conventional zone interface module Resonance isolator base Resonance packaged isolator LPCB Ref. No. 199v/07 199x/01 199x/02

Context Plus Ltd


Export House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom Tel: +44 (0)161 257 2541 Fax: +44 (0)161 225 8817 E-mail: xportsales@xportsales.com Website: www.xportsales.com
Certificate No: 010ap-(cl-2) to EN 54-17: 2005 Certificate No: 010ah to EN 54-18: 2005 and EN 54-17: 2005 Certificated Products 45681-505IMC 55000-843IMC 55000-845IMC 55000-847IMC 55000-852IMC Negative switching isolating base Analogue addressable switch monitor with isolator Analogue addressable zone monitor with isolator Analogue addressable input/output unit with isolator Analogue addressable sounder control unit with isolator LPCB Ref. No. 010ap/01 010ah/04 010ah/05 010ah/06 010ah/08

Detector Electronics Corporation


Minneapolis, Minesota 55438, United States Tel: +001 952 946 6488 E-mail: detronics@detronics.com Website: www.det-tronics.com
Certificate No: 973b to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products EQ3730ab(EDIO) Enhanced Discrete Input/Output Module with short circuit isolator Note 1: a refers to either D-DIN rail or P-panel mounting b refers to either W- non-SIL version or T- SIL version Note 2: The 750XCH-24D Magnecraft relay is an ancillary module used in conjunction with the EDIO module Note 3: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Note 4: The EQ3730ab(EDIO) is approved for use in an EQ5410 cabinet. Eight channel Relay Module with short circuit isolator Note 1: a refers to either D-DIN rail or P-panel mounting b refers to W- non-SIL version only Note 2: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Note 3: The EQ3720ab(RM) is approved for use in an EQ5410 cabinet. Analogue Input Module with short circuit isolator Note 1: a refers to either D-DIN rail or P-panel mounting b refers to W- non-SIL version only Note 2: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Note 3: The EQ3710ab(AIM) is approved for use in an EQ5410 cabinet. Signal Audible Module with short circuit isolator Note 1: The 750XCH-24D Magnecraft relay is an ancillary module used in conjunction with the SAM module. Note 2: The isolation is applied on the LON communication transmission path and not LPCB Ref. No. 973b/01

EQ3720ab(RM)

973b/02

EQ3710ab(AIM)

973b/03

EQ25EM(SAM)

973b/04

304

12 Sep 2011

PART 1: SECTION 6
LINE UNITS
Certificated Products the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Note 3: The EQ25EM(SAM) is approved for use in an EQ5410 cabinet. Initiating Device circuit with short circuit isolator Note 1: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone. Note 2: The EQ22EM(IDCSC) is approved for use in an EQ5410 cabinet. LPCB Ref. No.

EQ22EM(IDCSC)

973b/05

Emergi-Lite Safety Systems (Thomas & Betts Ltd)


Bruntcliffe Lane, Morley, Leeds LS27 9LL, United Kingdom Tel: +44 (0)113 2810600 Fax: +44 (0)113 2810601 Website: www.emergi-lite.co.uk
Certificate No: 010k to CEA GEI 1-052:11.06.97 Draft 2 Certificated Products FA95-LIU FA95-SMUPLUS FA95-1CI/O FA95-1CO FA95-SCC Negative short circuit isolator (FA95-LLB base) Notes: 1) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable switch monitor plus with isolator surface mounted Notes: 1) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable input/output unit with isolator surface mounted Notes: 1) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable output unit with isolator surface mounted Notes: 1) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols Analogue addressable sounder control unit with isolator surface mounted Notes: 1) Approved with Apollo Series 90, XP95 and Discovery digital communication protocols LPCB Ref. No. 010k/02 010k/05 010k/07 010k/08 010k/09

Bases: FA95-LLB Mounting base

FIREX Protection System Technology Ltd


28-38 Desborough Street, High Wycombe, Bucks, United Kingdom Tel: +44 (0)1494 601077 Fax: +44 (0)1494 601011 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 548m-(cl-3) to EN54-18: 2005 Certificate No: 548n-(cl-3) to EN54-17: 2005 Certificated Products FX9300I FX9301I FX9503 Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548m/01 548m/01 548n/01

12 Sep 2011

305

PART 1: SECTION 6
LINE UNITS

GE Security Inc
8985 Town Center Parkway, Bradenton, Florida 34202, United States Tel: (941) 739-42228 E-mail: gesecurity.customerservice@ge.com
Certificate No: 262y-(cl-1) to EN 54-18: 2005 Certificate No: 262x-(cl-1) to EN 54-17: 2005 Certificated Products SIGA-CC1 Single Input Signal Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGAMP2L Note 2: approved with personality code 5 Auto-Sync Output Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGAMP2L Note 2: approved with personality code 5 Dual Input Signal Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGAMP2L Note 2: approved with personality code 7 Universal Class A/B Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGAMP2L Note 2: approved with personality codes 3, 4, 8, 11, 12, 15, 16 and 18 Control Relay Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 8 Control Relay Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 8 Polarity Reversal Relay Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 8 Single Input Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality codes 3, 4 and 18 Dual Input Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality codes 3, 4 and 18 Monitor Module Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 3 Isolator Module (SIGA-MP1, SIGA-MP2 and SIGA-MP2L) LPCB Ref. No. 262y/01

SIGA-CC1S

262y/02

SIGA-CC2

262y/03

SIGA-UM

262y/04

SIGA-CR SIGA-CR2 SIGA-CRR SIGA-CT1 SIGA-CT2 SIGA-MM1 SIGA-IM Ancillaries SIGA-MP1 Mounting Plate SIGA-MP2 Mounting Plate SIGA-MP2L Mounting Plate

262y/05 262y/06 262y/07 262y/08 262y/09 262y/10 262x/01

GE Security Inc (Trading As Edwards System Technology)


8985 Town Center Parkway, Bradenton, Florida, United States Tel: 941 739-42228 E-mail: gesecurity.customerservice@ge.com
Certificate No: 902b-(cl-1) to EN-54-17: 2005 Certificated Products SIGA-IB Analogue addressable short circuit isolator base Note: 1) Certified for used with fire detector models LPCB Ref. No. 902b/01

306

12 Sep 2011

PART 1: SECTION 6
LINE UNITS
Certificated Products SIGA-IPHSI, SIGA-PHSI, SIGA-PSI, SIGA-ISI and SIGA-HRSI. SIGA-IB4 Analogue addressable short circuit isolator base (with 4 inch mounting adaptors) Note: 1) Certified for used with fire detector models SIGA-IPHSI, SIGA-PHSI, SIGA-PSI, SIGA-ISI and SIGA-HRSI. 902b/02 LPCB Ref. No.

Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk

Certificate No: 042ba to EN 54-17: 2005 & EN 54-18: 2005 Certificated Products S4-34410 S4-34411 S4-34415 S4-34420 S4-34450 Analogue addressable 1 input interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes) Analogue addressable 1 output DIN rail mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 output surface mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 input and 1 output interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes) Analogue addressable 4 input / output interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes) LPCB Ref. No. 042ba/01 042ba/02 042ba/03 042ba/04 042ba/05

Accessories: S4-34490 Plastic Box S4-34492 Metal Box

Global System Technology Plc


Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United Kingdom Tel: +44 (0)1283 225 478 Fax: +44 (0)1283 222 039 E-mail: info@gst.uk.com Website: www.gst.uk.com
Certificate No: 548m-(cl-1) to EN54-18: 2005 Certificate No: 548n-(cl-1) to EN54-17: 2005 Certificated Products I-9300 I-9301 C-9503 Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548m/01 548m/02 548n/01

12 Sep 2011

307

PART 1: SECTION 6
LINE UNITS

Group 4 Securicor Plc


Manor Royal, The Manor, Crawley, West Sussex RH10 9UN, United Kingdom Tel: +44 (0)20 87707000 Fax: +44 (0)20 87722531 Website: www.g4s.com
Certificate No: 548m-(cl-2) to EN54-18: 2005 Certificate No: 548n-(cl-2) to EN54-17: 2005 Certificated Products GS300I GS301I GS503C Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548m/01 548m/02 548n/01

Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn
Certificate No: 548n to EN 54-17: 2005 Certificate No: 548m to EN 54-18: 2005 Certificated Products GST-LD-8322 GST-LD-8300 GST-LD-8301 Loop isolator Analogue addressable input module Analogue addressable single input/output module LPCB Ref. No. 548n/01 548m/01 548m/02

HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 164b to EFSG/F/95/007 Certificate No: 164q to EN 54-17: 2005, EN 54-18: 2005 Certificate No: 164n to EN 54-17: 2005 Certificate No: 164p to EN 54-18: 2005

Line Units
Certificated Products 1433100 1433620 1433560 1433540 1433600 1226110 1433380 1433640 Dual Zone Monitor Intelligent analogue addressable single zone monitor with short circuit isolator Intelligent analogue addressable dual input module with short circuit isolator Intelligent analogue addressable dual sounder controller with short circuit isolator Intelligent analogue addressable dual relay controller with short circuit isolator Short Circuit Isolating Base Intelligent Analogue addressable powered output module Intelligent Analogue addressable single input module LPCB Ref. No. 164b/05 164q/01 164q/03 164q/05 164q/07 164n/01 164p/10 164p/11

308

12 Sep 2011

PART 1: SECTION 6
LINE UNITS

Hochiki Europe (UK) Limited


Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 Website: www.hochikieurope.com
Certificate No: 164b to EFSG/F/95/007 Certificate No: 164p to EN-54-18: 2005 Certificate No: 164q to EN 54-17: 2005, EN 54-18: 2005 Certificate No: 164n to EN 54-17: 2005

Line Units
Certificated Products CHQ-Z CHQ-SZM/OEM(SCI) CHQ-SZM/DIN(SCI) CHQ-DIM/OEM(SCI) CHQ-DIM/DIN(SCI) CHQ-DSC/OEM(SCI) CHQ-DSC/DIN(SCI) CHQ-DRC/OEM(SCI) CHQ-DRC/DIN(SCI) CHQ-SZM/OEM(HFP)-SCI CHQ-DIM/OEM(HFP)-SCI CHQ-DSC/OEM(HFP)-SCI CHQ-DRC/OEM(HFP)-SCI YBO-R/SCI(HFP) YBO-R/SCI(RED) YBO-R/SCI(WHT) YBO-R/SCI YBO-R/6R YBO-R/6R(WHT) YBO-R/6RS YBO-R/6RS(WHT) YBO-R/6RN YBO-R/6RN(WHT) CHQ-POM CHQ-SIM CHQ-POM(HFP) CHQ-SIM(HFP) CHQ-SZM/M(SCI) CHQ-DIM/M(SCI) CHQ-DSC/M(SCI) CHQ-DRC/M(SCI) YBO-R/SCIM Dual zone monitor Intelligent Analogue Addressable Single Zone monitor with Short Circuit Isolator Intelligent Analogue Addressable Single Zone monitor with Short Circuit Isolator (DIN rail version) Intelligent Analogue Addressable Dual Input Module with Short Circuit Isolator Intelligent Analogue Addressable Dual Input Module with Short Circuit Isolator (DIN rail version) Intelligent Analogue Addressable Dual Sounder Controller with Short Circuit Isolator Intelligent Analogue Addressable Dual Sounder Controller with Short Circuit Isolator (DIN rail version) Intelligent Analogue Addressable Dual Relay Controller with Short Circuit Isolator Intelligent Analogue Addressable Dual Relay Controller with Short Circuit Isolator (DIN rail version) Intelligent analogue addressable single zone monitor with short circuit isolator Intelligent analogue addressable dual input module with short circuit isolator Intelligent analogue addressable dual sounder controller with short circuit isolator Intelligent analogue addressable dual relay controller with short circuit isolator Short Circuit Isolating Base Short Circuit Isolating Base (RED) Short Circuit Isolating Base (WHITE) Short Circuit Isolating Base Conventional latching relay base Conventional latching relay base - White Conventional latching relay base with integral Schottky diode Conventional latching relay base with integral Schottky diode - White Conventional non-latching relay base Conventional non-latching relay base - White Intelligent Analogue addressable powered output module Intelligent Analogue addressable single input module Intelligent Analogue addressable powered output module Intelligent Analogue addressable single input module Intelligent analogue addressable single zone monitor with short circuit isolator Intelligent analogue addressable dual input module with short circuit isolator Intelligent analogue addressable dual sounder controller with short circuit isolator Intelligent analogue addressable dual relay controller with short circuit isolator Short Circuit Isolating Base LPCB Ref. No. 164b/05 164q/01 164q/02 164q/03 164q/04 164q/05 164q/06 164q/07 164q/08 164q/01 164q/03 164q/05 164q/07 164n/01 164n/02 164n/03 164n/01 164p/07 164p/07 164p/08 164p/08 164p/09 164p/09 164p/10 164p/11 164p/10 164p/11 164q/01 164q/03 164q/05 164q/07 164n/01

Honeywell Control Systems Limited


Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: +44 (0)1344 655609 Fax: +44 (0)1344 655474 Website: www.honeywellbuildingsolutions.co.uk
Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005 Certificated Products TC841E1019EIS TC809E1043 TC809E1050 Conventional zone monitor module with resistive end of line Analogue addressable single channel input module with short short circuit isolator Analogue addressable dual channel input module with short circuit isolator LPCB Ref. No. 199v/08 199v/01 199v/02

12 Sep 2011

309

PART 1: SECTION 6
LINE UNITS
Certificated Products TC809E1068 TC810E1032 TC810E1040 TC810E1057 TC841E1019 Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator LPCB Ref. No. 199v/03 199v/04 199v/05 199v/06 199v/07

Honeywell Control Systems Ltd


Honeywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United Kingdom Tel: 01344 655609 Fax: 01344 655474 Website: www.honeywellbuildingsolutions.co.uk
Certificate No: 262x-(cl-1) to EN54-17: 2005 Certificated Products XLS-IM Ancillaries SIGA-MP1 SIGA-MP2 SIGA-MP2L Isolator Module LPCB Ref. No. 262x/01

Mounting Plate Mounting Plate Mounting Plate

INIM Electronics s.r.l.


Via Fosso Antico - Loc, Centobuchi, 63033 Monteprandone (AP), Italy Tel: +39 0735 705007 Fax: +39 0735 704912 E-mail: enea.galiffa@inim.biz Website: www.inim.biz
Certificate No: 991g to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products EM312SR EU311 Analogue addressable Mini input/output module with short circuit isolator Analogue addressable Micro input/output module with short circuit isolator LPCB Ref. No. 991g/01 991g/02

Morley-IAS Fire Systems By Honeywell


Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@morleyias.co.uk Website: www.morley-ias.co.uk
Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005 Certificate No: 199r to CEA GEI 1-052 Draft 2.0: 11.06.97 & prEN 54-17 Draft: July 2002 Certificated Products MI-DMMI MI-DMM2I MI-D2ICMO MI-DCMO MI-D240CMO MI-240CMO-DIN MI-DCZM MI-DISO MI-DCZRM Analogue addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator Conventional zone interface module Short circuit isolator module Conventional zone monitor module with resistive end of line LPCB Ref. No. 199v/01 199v/02 199v/03 199v/04 199v/05 199v/06 199v/07 199r/01 199v/08

310

12 Sep 2011

PART 1: SECTION 6
LINE UNITS

Multron Systems Pte Ltd


217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 Fax: +65 6743 2777 / 6395 6869 E-mail: info@multron.com Website: www.multron.com
Certificate No: 548m-(cl-5) to EN54-18: 2005 Certificate No: 548n-(cl-5) to EN54-17: 2005 Certificated Products MOD-A300 MOD-A301 MOD-A503 Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548m/01 548m/02 548n/01

Nitin Ventures FZE


P.O. Box 262294, Jabel Ali Free Zone, Dubai, United Arab Emirates Tel: +97 148865858/859 Fax: +97 148865800 E-mail: sales@nitinventures.com Website: www.nitinventures.com
Certificate No: 010k- (cl-1) to CEA GEI 1-052: 11.06.97 Draft 2 Certificated Products NV-IA-ISO NV-IAII-SM NV-IAII-IO NV-IAII-O NV-IAII-SC NV-IAII-ZM Bases: NV-IA-ISOB Isolator Base Certificate No: 010aa-(cl-1) to EN 54-17:2005 Certificated Products NV-IA-IB Short circuit isolating base LPCB Ref. No. 010aa/01 Negative short circuit isolator (NV-IA-ISOB isolator base) Analogue addressable switch monitor with isolator - surface mounted Ananlogue addressable input/output unit with isolator - surface mounted Analogue addressable output unit with isolator - surface mounted Analogue addressable sounder control unit with isolator - surface mounted Analogue addressable zone monitor unit with isolator - surface mounted LPCB Ref. No. 010k/02 010k/06 010k/07 010k/08 010k/09 010k/10

Notifier Fire Systems by Honeywell


Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 Fax: +44 (0)1444 230888 E-mail: sales@notifiersystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 199r to CEA GEI 1-052 Draft 2.0: 11.06.97 & prEN 54-17 Draft: July 2002 Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005 Certificated Products M700X M710 M720 M721 Short circuit isolator module Analogue addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator LPCB Ref. No. 199r/01 199v/01 199v/02 199v/03

12 Sep 2011

311

PART 1: SECTION 6
LINE UNITS
Certificated Products M701 M701-240 M701-240-DIN M710-CZ M710-CZR Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator Conventional zone interface moudule Conventional zone monitor module with resistive end of line LPCB Ref. No. 199v/04 199v/05 199v/06 199v/07 199v/08

Pelco Finland Oy
Kalkkipellontie 6, PO Box 415, Fl-02601 Espoo, Finland Tel: +358 10 446 511 Fax: +358 10 446 5103 Website: www.pelco.com/nordic
Certificate No: 199x to EN 54-17: 2005 Certificate No: 199v to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products EMISO524 EM210ECZ EM210E-CZR Short circuit isolator Conventional zone interface module Conventional zone monitor module with resistive end of line LPCB Ref. No. 199x/02 199v/07 199v/08

Pittway Tecnologica Srl.


Via Caboto 19/3, 34147 Trieste, Italy Tel: +39 040 94 90111 Fax: +39 040 38 2137 E-mail: sandro_bonin@systemsensor.com Website: www.systemsensoreurope.com European Sales: System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, Switzerland Tel: +41 44 943 4424 Fax: +41 44 943 4399 E-mail: sse.marketing@systemsensor.com Website: www.systemsensor.com

Certificate No: 199r to CEA GEI 1-052 Draft 2.0 (11-06-97) and prEN 54-17 Draft (July 2002) Certificate No: 199x to EN 54-17: 2005 Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005 Certificated Products M200XE B524IEFT-1 ISO524-1 M210E M220E M221E M201E M201E-240 M201E-240-DIN M210E-CZ M210E-CZR Short circuit isolator module Short circuit isolator base Short circuit isolator module Analogue Addressable single channel input module with short circuit isolator Analogue addressable dual channel input module with short circuit isolator Analogue addressable dual channel input and single channel output module with short circuit isolator Single channel output module with short circuit isolator Single channel 240V output module with short circuit isolator Single channel 240V output module, DIN rail mount with short circuit isolator Conventional zone interface module Conventional zone monitor module with resistive end of line Will be labelled as M210E-CZR-yy, where yy indicates the protocol identifier option value between 00 and 99. LPCB Ref. No. 199r/01 199x/01 199x/02 199v/01 199v/02 199v/03 199v/04 199v/05 199v/06 199v/07 199v/08

312

12 Sep 2011

PART 1: SECTION 6
LINE UNITS

Protec Fire Detection plc


Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 Fax: +44 (0)1282 717273 E-mail: sales@protec.co.uk Website: www.protec.co.uk
Certificate No: 201t to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products 6000/CCO 6000/MIP Clean Contact Output Interface Module Monitored Input Interface Module LPCB Ref. No. 201t/01 201t/03

SHIELD FIRE, SAFETY & SECURITY LTD


28th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United Kingdom Tel: +44 161 257 2541 Fax: +44 161 225 8817 E-mail: dorota@xportsales.com Website: www.xportsales.com
Certificate No: 548m-(cl-4) to EN54-18: 2005 Certificate No: 548n-(cl-4) to EN54-17: 2005 Certificated Products AI-500 AI-510 AI-520 Analogue addressable input module Analogue addressable single input/output module Loop isolator LPCB Ref. No. 548m/01 548m/02 548n/01

Siemens Switzerland Limited, Building Technologies Division


International Headquarters, Fire Safety & Security Products, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 Fax: +41 (0) 41 724 35 22 Manufacturing at: Siemens Building Technologies AG, Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, Switzerland Tel: +41 1 922 6111 Fax: +41 1 922 6450

UK Sales: Tel: +44 (0)1189 783703 Fax: +44 (0)1189 775750 Website: www.sibt.com/www.uk.cerberus.com

Certificate No: 126m-(cl-1) to EN 54-17: 2005 and EN 54-18: 2005 Approved Products DC1192 Input/output module with short circuit isolator LPCB Ref. No. 126m/04

Certificate No: 126ae-(cl-1) to EN 54-17: 2005 Certificated Products FDCL221 Analogue addressable line separator with short circuit isolator LPCB Ref. No. 126ae/01

12 Sep 2011

313

PART 1: SECTION 6
LINE UNITS
Accessories: TS35 standard top hat rail Certificate No: 126ad-(cl-1) to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products FDCI222 Analogue addressable input module with short circuit isolator Note: 1. Approved when used with FDCH291 or FDCH292 enclosure or in a CIE enclosure compliant with EN 54-2 Analogue addressable input/output module with short circuit isolator Note: 1. Approved when used with FDCH291 or FDCH292 enclosure or in a CIE enclosure compliant with EN 54-2 LPCB Ref. No. 126ad/01

FDCIO222

126ad/02

Accessories: FDCM291 mounting foot TS35 standard top hat rail FDCH291 enclosure FDCH292 sealed enclosure Certificate No: 126aq-(cl-1) to EN 54-17:2005 and EN 54-18:2005 Certificated Products FDCIO223 Addressable transponder incorporating short circuit isolators (FDCH292, FDCM291) Note: 1. Approved when used in conjunction with housing box FDCH292 Digital addressable mimic display driver (F50F410, 520379) Note: 1. Approved when used with a metal enclosure at least complying with protection IP30 and weighing at least 4.5kg Floor repeater terminal Floor repeater display Housing box Mounting foot LED flat cable AC/AC Transformer LPCB Ref. No. 126aq/01

FT2001-A1

126aq/02

class 126aq/03 126aq/04

FT2010-A1 FT2011-A1 FDCH292 FDCM291 F50F410 520379

Certificate No: 531h-(cl-1) to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products FDCI221 FDCIO221 Analogue addressable input module Notes: 1. Approved when used with the FDCH221 Analogue addressable input module Notes: 1. Approved when used with the FDCH221 LPCB Ref. No. 531h/01 531h/02

Accessories FDCH221 Enclosure

Certificate No: 126au-(cl-1) to EN 54-17: 2005 Certificated Products FDCL221-M Multi line short circuit isolator module LPCB Ref. No. 126au/01

314

12 Sep 2011

PART 1: SECTION 6
LINE UNITS

SMS
Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: Nikki.Morgan@honeywell.com Website: www.gent.co.uk
Certificate No: 042ba to EN54-18: 2005, EN54-17: 2005 Certificated Products SEN-INT-INPUT SEN-INT-ACDIN SEN-INT-AC SEN-INT-AC SEN-INT-OUTPUT SEN-INT-4I0 Analogue addressable 1 input interface module with short circuit isolator low voltage (SEN-490 and SEN-492 boxes). Analogue addressable 1 output DIN rail mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 output DIN rail mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 output surface mounting interface module with short circuit isolator, medium voltage. Analogue addressable 1 input and 1 output interface module with short circuit isolator, low voltage (SEN-490 and SEN-492 boxes) Analogue addressable 4 input / output interface module with short circuit isolator, low voltage (SEN-490 and SEN-492 boxes) LPCB Ref. No. 042ba/01 042ba/02 042ba/03 042ba/03 042ba/04 042ba/05

Accessories: SEN-490 Plastic Box SEN-492 Metal Box

Thorn Security Limited, trading as Tyco Safety Products


Dunhams Lane, Letchworth SG6 1BE, United Kingdom Tel: +44 (0)1462 667700 Fax: +44 (0)1462 667777 E-mail: mashbury@tycoint.com Website: www.tycosafetyproducts-europe.com
Certificate No: 681k-(cl-1) to GEI 1-052: 11-06-97 Certificate No: 681t-(cl-1) to EN 54-18: 2005 Certificate No: 681u-(cl-1) to EN 54-18: 2005 Certificate No: 681v-(cl-1) to EN 54-17: 2005 & EN 54-18: 2005 Certificated Products 5BI 801IB 801RB HVR800 5" Isolator base Digital addressable isolator base Digital addressable relay base High voltage relay module Notes: 1. For use only with RIM800 relay interface module Contact input module Detector input module Relay interface module Mini input module Sounder notification module Extinguishing input module Small addressable multi input/output module Loop powered beam detector interface module Notes: 1. DDM800 LPCB Ref. No. 681k/01 681k/02 681k/03 681t/01

CIM800 DIM800 RIM800 MIM800 SNM800 LAV800 MIO800 BDM800

681t/02 681t/03 681t/04 681t/05 681t/06 681t/07 681t/08 681u/01

Approved when used in conjunction with the FIRERAY 2000/50R/100R beam detector and BTM800 thermal module 681v/01

Detector driver module with short circuit isolator Notes: 1. Approved for use with enclosure models M520 and D800

12 Sep 2011

315

PART 1: SECTION 6
LINE UNITS
Certificated Products 2. The unit is approved when powered from an EN 54-4 approved power source LPCB Ref. No.

Accessories M520 D800 Standard indoor enclosure Outdoor weatherproof enclosure

UTC Fire & Security (Africa) trading as Ziton


Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa Tel: +27 21 5066000 Fax: +27 21 5066100 Website: www.utcfireandsecurity.com UK Sales Enquiries: Ziton Limited Tel: +44 (0)1908 281981 Fax: +44 (0)1908 282554

UTC Fire & Security Americas Corporation, Inc.


129 North Main Street, Pittsfield, ME 04967, United States Tel: +1 207 487 3104 Fax: +1 207 487 5526 E-mail: leon.newsome@ge.com Website: www.gesecurity.com European Sales: Rudford Estate, Ford Aerodrome, Arundel, West Sussex BN18 0BE, United Kingdom Tel: +44 (0)1903 711 440 Fax: +44 (0)1903 711 448 E-mail: info@estinternational.com

Certificate No: 262d to EFSG/F/95/007 Approved Products SIGA-CC1 SIGA-CC2 SIGA-CT1I SIGA-CT2I Single input signal module Note: Approved using personality code 5 Dual input signal module Note: Approved using personality code 7 Single input module Note: Approved using personality codes 3, 4 and 18 Dual input module Note: Approved using personality codes 3, 4 and 18 LPCB Ref. No. 262d/01 262d/02 262d/03 262d/04

316

12 Sep 2011

PART 1: SECTION 6
LINE UNITS

UTC Fire & Security BV


Kelvinstraat 7, NL-6003DH, Weert, Netherlands Tel: + 31 495 58 30 00 Fax: + 31 495 55 00 42 E-mail: Daragh.O'Donnell@fs.utc.com Website: www.utcfireandsecurity.com
Certificate No: 092w-(cl-1) to EN 54-18:2005 Certificate No: 092t-(cl-1) to EN 54-17:2005 Certificate No: 092u-(cl-1) to EN 54-18:2005 Certificated Products A51E-1 EA51E-1 A70E-2 A60E-2 EA60E-2 ZP7-IB Analogue addressable high voltage relay module Analogue addressable high voltage relay module Analogue addressable conventional line interface module Notes: 1) The switched alarm output is not approved. Analogue addressable line isolator module Analogue addressable line isolator module Analogue addressable isolator base Note: 1) Approved for use with the following detectors: ZP710-2, ZP720-3, ZP730-2 & ZP732-2. Analogue addressable isolator base Note: 1) Approved for use with the following detectors: EA10E-2, EA20E-3, EA30E-2 & EA32E-2. Analogue addressable dual monitored sounder unit Note: 1) The external power supply must be compliant with EN 54-4 Analogue addressable dual monitored sounder unit Note: 1) The external power supply must be compliant with EN 54-4 Analogue addressable dual monitored sounder unit Note: 1) The external power supply must be compliant with EN 54-4 Analogue addressable single input interface module (Labelled Ziton) Analogue addressable single input interface module (Labelled EST) Analogue addressable line relay module (Labelled Ziton) Analogue addressable line relay module (Labelled EST) LPCB Ref. No. 092w/01 092w/01 092w/02 092t/01 092t/01 092t/02

EA-IB1

092t/02

ZP752-2

092w/03

EA752-2

092w/03

SOUNDI2000

092w/03

A45E-2 EA45E-2 A50E-2 EA50E-2

092u/01 092u/01 092u/02 092u/02

Vimpex Limited
Star Lane, Great Wakering, Essex SS3 0PJ, United Kingdom Tel: +44 (0) 1702 216999 Fax: +44 (0) 1702 216699 E-mail: sales@vimpex.co.uk Website: www.vimpex.co.uk
Certificate No: 456b to EN 54-17: 2005 Certificate No: 456c to EN 54-17: 2005 and EN 54-18: 2005 Certificated Products BA873x0/MT/SCI Isolating sounder base (shallow) Notes: 1 Key for certification; x indicates body colour: 3 = White, 4 = Red. LPCB Ref. No. 456b/01

12 Sep 2011

317

PART 1: SECTION 6
LINE UNITS
Certificated Products 2 3 The device is approved when used with the DINT1 Interface (refer to LPCB Cert. Ref. 456c). The device is approved when used with the Hosiden Besson Sounder Banshee MT and Sounder/Strobe LED Flashtone Banshee MT. (refer to LPCB Cert. Ref. 715a). 456b/02 LPCB Ref. No.

BA873x1/MT/SCI

DINT1

Isolating sounder base (deep) Notes: 1 Key for certification; x indicates body colour: 3 = White, 4 = Red. 2 The device is approved when used with the DINT1 Interface (refer to LPCB Cert. Ref. 456c). 3 The device is approved when used with the Hosiden Besson Sounder Banshee MT and Sounder/Strobe LED Flashtone Banshee MT. (refer to LPCB Cert. Ref. 715a). Isolating Sounder Interface Card Notes: 1. The device is approved for use with the BA873xx/MT/SCI series Isolating Sounder Bases (refer to LPCB Cert. Ref. 456b)

456c/01

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 010ap-(cl-1) to EN 54-17: 2005 Certificated Products 80-090 Fyreye FE IB Negative switching isolating base LPCB Ref. No. 010ap/01

318

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES Fire alarm devices: The purpose of a fire alarm devices is to warn person(s) within, or in the vicinity of, a building of the occurrence of a fire emergency situation in order to enable such person(s) to take appropriate measures. Fire alarm warning devices could be sounders, visual alarm e.g. beacons, or even loudspeakers. These devices can be of different construction and may have different parameters for example sounders are defined in terms of frequency ranges, temporal patterns and output levels, beacons are defined in terms of light temporal pattern and frequency of flashing. Guidance on the type, frequency, temporal pattern, and output levels should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). For example BS 5839-1 recommends sounders with continuous output and frequency range between 500 Hz to 1000 Hz. Fire alarm devices may be used for other type of risk or non-fire emergency alarm. In this case it is always recommended that a different message, colour, temporal pattern, or frequency signal from the fire signal is selected to avoid confusion. This section lists alarm device approved for use indoors and outdoors in fire detection and fire alarm systems. The initial approval and continued approval processes for sounders are outlined in scheme document SD039. Products listed in this section have been approved to: EN 54-3: 2001 Sounders EN 54-3: 2001 + A1: 2002 + A2: 2006 Sounders The initial approval and continued approval processes for visual are outlined in scheme document SD115. Products listed in this section have been approved to: EN 54-23: 2010 visual alarms The initial approval and continued approval processes for loudspeakers are outlined in scheme document SD113. Products listed in this section have been approved to: EN 54-24: 2008 Loudspeakers Audit: Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: 1. EN 54-3: 2001 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that sounders are certificated to EN 54-3: 2001. 2. EN 54-23: 2010 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 March 2013. It is therefore recommended that sounders are certificated to EN 54-23: 2010. 3. EN 54-24: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 April 2011. It is therefore recommended that sounders are certificated to EN 54-24: 2008. 4. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

12 Sep 2011

319

PART 1: SECTION 7
ALARM WARNING DEVICES

Advanced Electronics Limited


34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0) 1226 737 465 Fax: +44 (0) 1226 737 469 E-mail: ithompson@advel.co.uk Website: www.Advel.co.uk
Certificate No: 928g-(cl-5) to EN 54-3: 2001 + A1: 2002 and EN 54 -17: 2005 Certificated Products 20-VLS100-ADV Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady LPCB Ref. No. 928g/01

Advantronic Systems S.L.


C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, Spain Tel: +34 91 806 2343 Fax: +34 91 803 1171 E-mail: jpedrouzo@advantronic.es Website: www.advantronic.es
Certificate No: 928g-(cl-3) to EN 54-3: 2001 + A1: 2002 and EN 54 -17: 2005 Certificated Products AV112AL Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady LPCB Ref. No. 928g/01

Apollo Fire Detectors Limited


36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 Fax: +44 (0)2392 492754 E-mail: enquiries@apollo-fire.co.uk
Certificate No: 010af to EN 54-3: 2001

Wireless Sounders
Certificated Products XPA-SO-14001-APO Xpander addressable sounder (Red ) (XPA-SB-10023-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14001-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder (White) (XPA-SB-10024-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14002-APO 3) The device must be used with the following batteries only: LPCB Ref. No. 010af/01

XPA-SO-14002-APO

010af/02

320

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products LPCB Ref. No.

XPA-SN-14003-APO

MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder strobe (Red head / red lens) (XPA-SB-10023-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14003-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval.
Xpander addressable sounder beacon (Red head / amber lens) (XPA-SB-10024-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14004-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval. Xpander addressable sounder beacon (White head / clear lens) (XPA-SB-10024-APO mounting base) Notes: 1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 13 2) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14005-APO 3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells 4) The radio link functionality is not included within the scope of approval.

010af/03

XPA-SN-14004-APO

010af/04

XPA-SN-14005-APO

010af/05

Bases: XPA-SB-10023-APO Radio link mounting base - red XPA-SB-10024-APO Radio link mounting base - white Certificate No: 010ak to EN54-3: 2001 +A1:2002 +A2:2006

Sounders
Certificated Products 55000-001 XP95 Type B intelligent open area sounder (Red) Note: 1. Meets the requirements of EN 54-3:2001 at the following tones: Apollo standard-840Hz,0.5s/558Hz,0.5s Dutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s XP95 Type B intelligent open area sounder (White) Note: 1. Meets the requirements of EN 54-3:2001 at the following tones: Apollo standard-840Hz,0.5s/558Hz,0.5s Dutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s XP95 Type B intelligent open area sounder beacon (Red) Note: 1. Meets the requirements of EN 54-3:2001 at the following tones: Apollo standard-840Hz,0.5s/558Hz,0.5s Dutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s XP95 Type B intelligent open area sounder beacon (White) Note: 1. Meets the requirements of EN 54-3:2001 at the following tones: Apollo standard-840Hz,0.5s/558Hz,0.5s Dutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off LPCB Ref. No. 010ak/01

55000-002

010ak/02

55000-005

010ak/03

55000-006

010ak/04

12 Sep 2011

321

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products German DIN-1200-500Hz over 1s 58000-005 Discovery Type B intelligent open area sounder beacon (Red) enhanced deep isolating bases) Note: 1. Meets the requirements of EN 54-3:2001 at the following tones: T1- Apollo Evacuation 558Hz,0.5s/840Hz,0.5s T3- Dutch Slow Whoop 500-1200Hz in 3.5s, 0.5s off T4- German DIN1200-500Hz over 1s Discovery Type B intelligent open area sounder beacon (White) enhanced deep isolating bases) Note: 1. Meets the requirements of EN 54-3:2001 at the following tones: T1- Apollo Evacuation 558Hz,0.5s/840Hz,0.5s T3- Dutch Slow Whoop 500-1200Hz in 3.5s, 0.5s off T4- German DIN1200-500Hz over 1s 010ak/05 LPCB Ref. No.

58000-007

010ak/06

Bases: 45681-517 Enhanced deep isolating base (White) 45681-518 Enhanced deep isolating base (Red)

Argus Security S.r.l.


Via Josip Ressel 2/7, S Dorligo della Valle, 34018 Trieste, Italy Tel: +39 (0) 402821110 Fax: +39 (0) 402823483 E-mail: dcresseri@argussecurity.it Website: www.argussecurity.it
Certificate No: 928g to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54 -17: 2005

Sounders
Certificated Products VLS100-H Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Slow whoop tone 500 to 1200Hz, 3s sweep, 0.5s silence Sweep (DIN) tone 1200 to 500Hz, 1Hz Continuous tone 990Hz, steady Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF) Continuous tone 990Hz, steady LPCB Ref. No. 928g/02

VLS100

928g/01

Argus-Spectrum Co
65 Serdobolskaya St, St. Petersburg 197342, Russian Federation Tel: +7 812 7037500 Fax: +7 812 7037501 E-mail: mail@argus-spectr.ru Website: www.argus-spectr.ru
Certificate No: 928g-(cl-2) to EN54-3: 2001 + A1: 2002 and EN 54 -17: 2005 Certificated Products VLS100-H Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Slow whoop tone 300 to 1200Hz, 3s sweep, 0.5s silence LPCB Ref. No. 928g/02

322

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products Sweep (DIN) tone 1200 to 500Hz, 1Hz Continuous tone 990Hz, steady Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady LPCB Ref. No. 928g/01

VLS100

ATEIS Middle East FZCO


LIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab Emirates Tel: +971 4 6091325 Fax: +971 4 6091326 E-mail: info@ateis.ae Website: www.ateis.ae
Certificate No: 928g-(cl-7) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products VELOX VLS100 Analogue addressable Type A sounder with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone: 990 and 650Hz, 2Hz (250ms-250ms) Pulsed tone: 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone: 990Hz, steady Analogue addressable Type A sounder with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at the following tone settings: Slow whoop tone 500 to 1200Hz, 3s sweep, 0.5s silence Sweep (DIN) tone 1200 to 500Hz, 1Hz Continuous tone 990Hz, steady LPCB Ref. No. 928g/01

VELOX VLS100-H

928g/02

Autronica Fire & Security AS


Postboks 5620 NO-7483, Trondheim, Norway Tel: +47 73582500 Fax: +47 73582501 E-mail: info@autronicafire.no Website: www.autronicafire.no
Certificate No: 378h-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products 116-BBQ-230 Addressable indoor sounder and beacon with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) 2) the beacon functionality is not included within the scope of this approval Addressable outdoor sounder and beacon with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) 2) the beacon functionality is not included within the scope of this approval Addressable indoor sounder with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: LPCB Ref. No. 378h/01

116-BBQ-230/IP

378h/02

116-BBR-230

378h/03

12 Sep 2011

323

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) Addressable outdoor sounder with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) Addressable indoor base sounder with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) Addressable indoor base sounder and beacon with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) 2) the beacon functionality is not included within the scope of this approval Addressable indoor base sounder with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) Addressable indoor base sounder and beacon with isolator Notes: 1) meets the requirements of EN 54-3: 2001 for the following tones: - General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz) 2) the beacon functionality is not included within the scope of this approval LPCB Ref. No.

116-BBR-230/IP

378h/04

116-BBR-130

378h/05

116-BBQ-130

378h/06

116-BBR-131

378h/07

116-BBQ-131

378h/08

Ceasefire Industries Ltd


"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, India Tel: +91 -22-22854677, 22854678 Fax: +91-22-66349069 E-mail: response@ceasefire.in Website: www.ceasefire.in
Certificate No: 164h-(cl-1) to EN54-3:2001 Certificated Products YBO-BSB (WHT) Loop powered base sounder and beacon (YBN-R/3 and YBO-R/SCI bases). 1) The beacon function of this device is not included in the scope of this approval. 2) Meets the requirements of EN54-3 at the following tones: 1) - 925 Hz : 250 ms / 628 Hz : 250 ms 2) - 925 Hz Continuous 3) - 628 Hz Continuous 4) - (French) 554 Hz : 100 ms/ 440 Hz : 400 ms 5) - (Swedish) 660 Hz : 150 ms/ Off : 150 ms LPCB Ref. No. 164h/03

324

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 6) - 925Hz : 15oms / Off : 600 ms 7) - 670 hZ : 250MS / 845 hZ : 370 MS 8) - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9) - 1200 Hz : 500 ms/ 500 Hz : 500 ms 10) - 970 Hz : 500 ms / Off : 500 ms 11) - Sweet 800 Hz - 970 Hz over 140 ms (7 Hz) 12) - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13) - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14) - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15) - Sweet 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16) - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17) - ISO8201 : 970 Hz : 500 ms 18) - ISO8201 : 2850 Hz : 500 ms 19) - 800 Hz : 250 ms / 970 Hz : 250 ms 20) - 2850 Hz Continuous 21) - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22) - 800 Hz : 500 ms / 970 Hz : 500 ms 23) - 2850 Hz : 500 ms / Off : 500 ms 24) - 925 Hz : 250 ms / Off : 1000 ms 25) - 970 Hz Continuous 26) - 660 Hz : 1800 ms / Off: 1800 ms 27) - 660 Hz : 6500 ms / Off : 13000 ms 28) - 660 Hz Continuous 29) - 554 Hz : 500 ms / 440 Hz : 500 ms 30) - 660 Hz : 500 ms / Off : 500 ms 31) - 2850 Hz : 150 ms / Off : 100 ms 32) - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33) - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34) - 988 Hz : 250 ms / 645 Hz : 250 ms 35) - 510 Hz : 250 ms / 610 Hz : 250 ms 36) - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37) - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38) - 845 Hz Continuous 39) - 970 Hz : 1000 ms / Off : 1000 ms 40) - 800 Hz : 150 ms / 970 Hz : 150 ms 41) - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42) - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43) - 2850 Hz : 1000 ms / Off : 1000 ms 44) - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45) - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46) - 440 Hz : 600 ms / Off : 600 ms 47) - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48) - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49) - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50) - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51) - Whoop 500-1200 3.5s/0.5s Bases YBN -R/3 base YBO-R/SCI isolator base Certificate No: 715a-(cl-2) to EN54-3:2001 Certificated Products Banshee MT Sounder (892 shallow base version and 893 deep base version) 1. Certified to EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Sound 143 Banshee HF (and Bedlam) Sound 19 Slow Whoop (Dutch) Sound 20 DIN Klung (German) 2. Approved as Type A when used with shallow base (892) & Type B when used with deep base (B93). 3. Approved voltage range 10-28V. Bases 892 shallow base 893 deep base LPCB Ref. No. 715a/01 LPCB Ref. No.

12 Sep 2011

325

PART 1: SECTION 7
ALARM WARNING DEVICES

Cooper Fulleon Limited


Llantarnam Park, Cwmbran, South Wales NP44 3AW, United Kingdom Tel: +44 (0)1633 628500 Fax: +44 (0)1633 866346 E-mail: sales@fulleon.co.uk Website: www.cooperfulleon.com
Certificate No: 378b to EN54-3: 2001 + A1: 2002 + A2: 2006 Certificated Products ROLP Roshni Conventional Type A/B LP Sounder Notes: 1. The sounder is approved in red and white colours 2. Using Deep, U-shaped and shallow sounder bases in red and white colours 3. Meets the requirements of EN54-3: 2001 at the following tones: 3 - Sweep 800Hz - 970Hz in 1s 7 - Slow whoop 500Hz - 1200Hz in 3.5s - 0.5s silence 8 - Sweep 1200Hz - 500Hz in 1s 14 - Continuous 970Hz steady 29 - Alternating 990Hz 250ms / 650Hz 250ms 30 - Alternating 510Hz 250ms / 610Hz 250ms Conventional Type A/B LP Sounder Notes: 1. The sounder is approved in red and white colours 2. Using Deep, U-shaped and shallow sounder bases in red and white colours 3. Meets the requirements of EN54-3: 2001 at the following tones: 3 - Sweep 800Hz - 970Hz in 1s 7 - Slow whoop 500Hz - 1200Hz in 3.5s - 0.5s silence 8 - Sweep 1200Hz - 500Hz in 1s 14 - Continuous 970Hz steady 29 - Alternating 990Hz 250ms / 650Hz 250ms 30 - Alternating 510Hz 250ms / 610Hz 250ms LPCB Ref. No. 378b/01

ROLP/SV Roshni

378b/02

Cranford Controls Limited


Unit 2, Waterbrook Estate, Waterbrook Road, Alton, Hampshire GU34 2UD, United Kingdom Tel: +44 (0)1420 592444 Fax: +44 (0)1420 592445 E-mail: sales@cranfordcontrols.com Website: www.cranfordcontrols.com
Certificate No: 546a to EN 54-3: 2001 + A1: 2002 + A1: 2006 Certificated Products VTG-32E-SB Conventional indoor Type A sounder Notes: 1) The sounder is approved in red and white colours (-R and -W suffixes) 2) Certified to EN54-3: 2001 with the following selectable tones: 1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms) 2 nd Stage tone for all above (800Hz continuous tone) 11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off) Conventional outdoor Type B sounder Notes: 1) The sounder is approved in red and white colours (-R and -W suffixes) 2) Certified to EN54-3: 2001 with the following selectable tones: 1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms) 2 nd Stage tone for all above (800Hz continuous tone) 11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off) Conventional outdoor Type B sounder (116-100 mounting base) Notes: 1) Certified to EN54-3: 2001 with the following selectable tones: LPCB Ref. No. 546a/01

VTG-32E-DB

546a/01

VPR-DT

546a/02

326

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 1 - Evacuate Tone (500-1200Hz Rising Sweep over 3.5 Sec 0.5 Sec off) 2 - Alert Tone (970Hz Continuous Tone) 2) Certified at Maximum Volume only. Conventional indoor Type A sounder base Notes: 1) This sounder meets the requirements of EN 54-3:2001 for the following tones at low, medium and high volume settings: 1 - LF Sweep (Cranford sweep) (800-1000Hz @ 0.5 Sec) 3 - Alternative Warble (800-1000Hz @ 0.5 Sec) 11 - Dutch Sweep Tone (970Hz Cont) 25 - German DIN Tone (Sweep 1200-500Hz @ 1Hz) 27- French Tone AFNOR (554Hz 100ms and 440Hz for 400 ms) 2) Cover plate (Part No. 116-099) must be used . LPCB Ref. No.

VSO-32

546a/04

Base: 116-100 Viper Mounting Base

EMCO
125 El Alamean Street, El Mohandessin, Cairo, Egypt Tel: 00202 33 44 3 245 Fax: 00202 330 36 86 0 E-mail: emco@4emco.com Website: www.4emco.com
Certificate No: 928g to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products AS200 Analogue addressable Type A sounder with short circuit isolator LPCB Ref. No. 928g/01

Notes: 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone 990Hz, steady

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)


P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates Tel: +971 6 5340300 Fax: +971 6 5340090 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 506e to EN 54-3: 2001 Certificated Products FX-0218 Conventional fire alarm bell LPCB Ref. No. 506e/01

Fireguard Safety Equipment Co Ltd


2nd Floor, 145-147 St John Street, London EC1V 4PY, United Kingdom Tel: +44 (0)8450 751042 Fax: +44 (0)8450 751043 E-mail: info@fireguard-uk.com Website: www.fireguard-uk.com
Certificate No: 506e-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificated Products FG-0218 FG-03127S Conventional fire alarm bell Conventional Type A electronic sounder LPCB Ref. No. 506e/01 506e/02

12 Sep 2011

327

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products Notes: Meets the requirements of EN54-3: 2001 at the following tones 1-Alternating Tones 800/970Hz at 2Hz 2-Sweeping 800/970Hz at 7Hz LPCB Ref. No.

FIREX Protection System Technology Ltd


28-38 Desborough Street, High Wycombe, Bucks, United Kingdom Tel: +44 (0)1494 601077 Fax: +44 (0)1494 601011 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 548e to EN 54-3: 2001 Certificated Products FX9403 FX9403I Conventional sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/01 548e/02

GE Security Inc (Trading As Edwards System Technology)


8985 Town Center Parkway, Bradenton, Florida, United States Tel: 941 739-42228 E-mail: gesecurity.customerservice@ge.com
Certificate No: 902a-(cl-1) to EN-54-3: 2001 + A1:2002 + A2:2006 Certificated Products SIGA-AB4G Analogue addressable Type A sounder base Notes: 1) Certified for used with fire detector models SIGA-IPHSI, SIGA-PHSI, SIGA-PSI, SIGA-IS and SIGA-HRSI. 2) Meets the requirements of EN 54-3 with Steady and Temporal tones, and operating voltages from 16-33 VDC. 3) Certified for use with AB4G-SB surface mounting box. LPCB Ref. No. 902a/01

Ancillary AB4G-SB Surface mounting box

Gent By Honeywell
140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 Fax: +44 (0)116 246 2300 E-mail: gent_enquiry@gent.co.uk Website: www.gent.co.uk
Certificate No: 042ah to EN 54-3: 2001 Certificate No: 042ar to EN 54-3: 2001 +A1 , CEA GEI 1-052- Draft 2.0 11-06-97 Certificate No: 042bj to EN 54-3: 2001 + A1: 2002 + A2: 2006, EN 54-17: 2005 Certificate No: 042bk to EN 54-3: 2001 + A1: 2002 + A2: 2006

328

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products S3-SN-R S3-SN-W S3IP-SN-R S3IP-SN-W S2IP-SN-R S2IP-SN-W S2IP-SN-R3 S2IP-SN-W3 S3-SN-ST-RR S3-SN-ST-WR S3IP-SN-ST-RR S3IP-SN-ST-WR S3IP-SN-ST-RW S31P-SN-ST-WA S3-VO-R S3-VO-W S3IP-VO-R S3IP-VO-W S2IP-VO-R S2IP-VO-W S3-VO-ST-RR S3-VO-ST-WR S3IP-VO-ST-RR S3IP-VO-ST-WR S3-SN-R S3-SN-W S3IP-SN-R S3IP-SN-W S2IP-SN-R S2IP-SN-W S2IP-SN-R3 S2IP-SN-W3 S3-SN-ST-RR S3-SN-ST-WR S3IP-SN-ST-RR S3IP-SN-ST-WR S3IP-SN-ST-RW S3IP-SN-ST-WA S3-SN-R-V2 Red LP Indoor Analogue Addressable Sounder White LP Indoor Analogue Addressable Sounder Red Outdoor Analogue Addressable Sounder White Outdoor Analogue Addressable System Sounder Red Outdoor Analogue Addressable System Sounder White Outdoor Analogue Addressable System Sounder 3 Way Red Outdoor Analogue Addressable System Sounder 3 Way White LP Outdoor Analogue Addressable Sounder/Strobe Red Lens Red LP Indoor Analogue Addressable Sounder/Strobe Red Lens White LP Indoor Analogue Addressable Sounder/Strobe Red Lens Red Outdoor Analogue Addressable Sounder/Strobe Red Lens White Outdoor LP Analogue Addressable Sounder/Strobe Red Lens Red Outdoor Analogue Addressable Sounder/Strobe 2 Way White Lens White Outdoor Analogue Addressable Sounder/Strobe 2 Way Amber Lens Red LP Indoor Voice Analogue Addressable Sounder White LP Indoor Voice Analogue Addressable Sounder Red LP Outdoor Voice Analogue Addressable Sounder White LP Outdoor Voice Analogue Addressable Sounder Red Outdoor Voice Analogue Addressable Sounder White Outdoor Voice Analogue Addressable Sounder Red LP Indoor Voice Analogue Addressable Sounder/Strobe Red Lens White LP Indoor Voice Analogue Addressable Sounder/Strobe Red Lens Red Outdoor Voice Analogue Addressable Sounder/Strobe Red Lens White LP Outdoor Voice Analogue Addressable Sounder/Strobe Red Lens Analogue Addressable Red LP Indoor Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White LP Indoor Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor System Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor System Sounder with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor System Sounder 3 Way with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor System /Sounder 3 Way with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White LP Outdoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red LP Indoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White LP Indoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor LP Sounder/Strobe Red Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable Red Outdoor Sounder/Strobe 2 Way White Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Analogue Addressable White Outdoor Sounder / Strobe 2 Way Amber Lens with short circuit isolator Note: Meets the requirements of EN 54-3:2001 at Low Tone and High Tone Addressable Red LP Indoor Sounder with short circuit isolator Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable White LP Indoor Sounder with short circuit isolator Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable Red Outdoor Sounder with short circuit isolator Note: LPCB Ref. No. 042ah/01 042ah/02 042ah/03 042ah/04 042ah/05 042ah/06 042ah/07 042ah/08 042ah/09 042ah/10 042ah/11 042ah/12 042ah/13 042ah/14 042ah/15 042ah/16 042ah/17 042ah/18 042ah/19 042ah/20 042ah/21 042ah/22 042ah/23 042ah/24 042ar/01 042ar/02 042ar/03 042ar/04 042ar/05 042ar/06 042ar/07 042ar/08 042ar/09 042ar/10 042ar/11 042ar/12 042ar/13 042ar/14 042bj/01

S3-SN-W-V2

042bj/02

S3IP-SN-R-V2

042bj/03

12 Sep 2011

329

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable White Outdoor Sounder with short circuit isolator Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable White Outdoor Sounder with short circuit isolator Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable Red Outdoor Sounder with short circuit isolator Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable White Outdoor Sounder with short circuit isolator Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Analogue Addressable Red LP Indoor Sounder/Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable White LP Indoor Sounder/Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red Outdoor Sounder/Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable White Outdoor LP Sounder/Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red Outdoor Sounder/Strobe White Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red Outdoor System Voice Enhanced Sounder with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. LPCB Ref. No.

S3IP-SN-W-V2

042bj/04

S2IP-SN-R-V2

042bj/05

S2IP-SN-R-V2

042bj/05

S2IP-SN-W-V2

042bj/06

S3-SN-ST-RR-V2

042bj/07

S3-SN-ST-WR-V2

042bj/08

S3IP-SN-ST-RR-V2

042bj/09

S3IP-SN-ST-WR-V2

042bj/10

S3IP-SN-ST-RW-V2

042bj/11

S2IP-VP-R

042bj/12

330

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red LP Indoor Sounder Voice Enhanced with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable White LP Indoor Sounder Voice Enhanced with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable White LP Indoor Sounder Voice Enhanced /Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red LP Indoor Sounder Voice Enhanced /Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red Outdoor LP Sounder Voice Enhanced with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable White Outdoor LP Sounder Voice Enhanced with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable White Outdoor LP Sounder Voice Enhanced / Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Analogue Addressable Red Outdoor LP Sounder Voice Enhanced / Strobe Red Lens with short circuit isolator Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes strobe function. Conventional Red LP Indoor Sounder Note: Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. LPCB Ref. No.

S3-VP-R

042bj/13

S3-VP-W

042bj/14

S3-VP-ST-WR

042bj/15

S3-VP-ST-RR

042bj/16

S3IP-VP-R

042bj/17

S3IP-VP-W

042bj/18

S3IP-VP-ST-WR

042bj/19

S3IP-VP-ST-RR

042bj/20

C3-SN-R-V2

042bk/01

12 Sep 2011

331

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products C3-SN-W-V2 Conventional White LP Indoor Sounder Note: Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Conventional Red LP Outdoor Sounder Note: Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Conventional White LP Outdoor Sounder Note: Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. Conventional Red LP Indoor Sounder/Strobe Red Lens Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes Strobe function. Conventional White LP Indoor Sounder/Strobe Red Lens Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes Strobe function. Conventional Red LP Outdoor Sounder/Strobe Red Lens Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes Strobe function. Conventional White LP Outdoor Sounder/Strobe Red Lens Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes Strobe function. Conventional Red LP Indoor Sounder Voice Enhanced /Strobe Red Lens Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes Strobe function. Conventional White LP Indoor Sounder Voice Enhanced /Strobe Red Lens Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz. 2. Certification excludes Strobe function. LPCB Ref. No. 042bk/02

C3IP-SN-R-V2

042bk/03

C3IP-SN-W-V2

042bk/04

C3-SN-ST-RR-V2

042bk/05

C3-SN-ST-WR-V2

042bk/06

C3IP-SN-ST-RR-V2

042bk/07

C3IP-SN-ST-WR-V2

042bk/08

C3-VP-ST-RR

042bk/09

C3-VP-ST-WR

042bk/10

Bases: Shallow Base IP31C Deep Base IP55C Note All products may be used with either base

332

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES

Global System Technology Plc


Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United Kingdom Tel: +44 (0)1283 225 478 Fax: +44 (0)1283 222 039 E-mail: info@gst.uk.com Website: www.gst.uk.com
Certificate No: 548e to EN 54-3:2001 Certificated Products C-9403 I-9403 Conventional sounder strobe Notes:Meets the requirements of EN 54-3: 2001 at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Notes:Meets the requirements of EN 54-3: 2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/01 548e/02

Group 4 Securicor Plc


Manor Royal, The Manor, Crawley, West Sussex RH10 9UN, United Kingdom Tel: +44 (0)20 87707000 Fax: +44 (0)20 87722531 Website: www.g4s.com
Certificate No: 548e to EN 54-3:2001 Certificated Products GS403C GS403I Conventional sounder strobe Note: Meets the requirements of EN 54-3:2001 at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Note: Meets the requirements of EN 54-3:2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/01 548e/02

Gulf Security Technology Co. Ltd (Manufacturing Division of Global System Technology PLC)
No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502528 Fax: +86 0335 8508942 E-mail: gst@gst.com.cn Website: www.gst.com.cn
Certificate No: 548e to EN 54-3:2001 Certificated Products GST-HX-F8502 GST-HX-M8502 Conventional sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/01 548e/02

12 Sep 2011

333

PART 1: SECTION 7
ALARM WARNING DEVICES

HDR
Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 E-mail: info@hochikieurope.com Website: www.hochikieurope.com
Certificate No: 164h to EN 54 3: 2001 Certificated Products 1460040 Loop Powered Base Sounder (1426010 and 1226110 bases) Notes: 1) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop Powered Sounder/Base (1426010 and 1226110 bases) Notes 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous LPCB Ref. No. 164h/01

1460070

164h/03

334

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop Powered Sounder Wall Sounder (1426010 and 1226110 bases) Notes: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered wall sounder beacon (YBN-R/3 and YBO-R/SCI bases) Note: 1 The beacon function of this device is not included in the scope of this approval 2 Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms LPCB Ref. No.

1460050

164h/02

1460090

164h/04

12 Sep 2011

335

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s LPCB Ref. No.

Bases: 1226110 Isolator base 1426010 Standard Base

Hochiki Europe (UK) Limited


Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 Fax: +44 (0)1634 260132 Website: www.hochikieurope.com
Certificate No: 164h to EN 54 3: 2001 Certificated Products YBO-BS(HFP) Loop powered base sounder (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms LPCB Ref. No. 164h/01

336

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered base sounder white version (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms LPCB Ref. No.

YBO-BS(WHT)

164h/01

12 Sep 2011

337

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered wall sounder (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered wall sounder - white version (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered wall sounder - weatherproof version (YBN-R/3, YBO-R/SCI and WS2WPK base) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered base sounder and beacon (YBN-R/3 and YBO-R/SCI bases) Notes: 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms LPCB Ref. No.

CHQ-WS2(HFP)

164h/02

CHQ-WS2(WHT)

164h/02

CHQ-WS2/W

164h/02

YBO-BSB(HFP)

164h/03

338

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered base sounder and beacon white version (YBN-R/3 and YBO-R/SCI bases) Notes: 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms LPCB Ref. No.

YBO-BSB(WHT)

164h/03

12 Sep 2011

339

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered base sounder (YBN-R/3 and YBO-R/SCI bases) Notes: 1) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms LPCB Ref. No.

YBO-BS

164h/01

340

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered base sounder and beacon (YBN-R/3 and YBO=R/SCI bases) Notes: 1) The beacon function of this device is not included in the scope of this approval 2) Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered wall sounder (YBN-R/3 and YBO-R/SCI bases) Note: 1) Meets the requirements of EN 54-3 at the following tones: H1 - 925/628 at 2Hz LPCB Ref. No.

YBO-BSB

164h/03

CHQ-WS2

164h/02

12 Sep 2011

341

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s Loop powered wall sounder beacon (YBN-R/3 and YBO-R/SCI bases) Note: 1 The beacon function of this device is not included in the scope of this approval 2 Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s CHQ-WSB (WHT) Loop powered wall sounder beacon (YBN-R/3 and YBO-R/SCI bases) Note: 1 The beacon function of this device is not included in the scope of this approval 2 Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 164h/04 LPCB Ref. No.

CHQ-WSB

164h/04

342

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Loop powered wall sounder beacon (YBN-R/3 and YBO-R/SCI bases) Note: 1 The beacon function of this device is not included in the scope of this approval 2 Meets the requirements of EN 54-3 at the following tones: 1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous LPCB Ref. No.

CHQ-WSB(HFP)

164h/04

12 Sep 2011

343

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms Continued . 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s Bases: YBN-R/3 Analogue mounting base (ivory and white) YBO-R/SCI Isolator base LPCB Ref. No.

Horing LIH Industrial Co Ltd


No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC Tel: +886 2 22487599 Fax: +886 2 22407752
Certificate No: 506e to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificated Products AH-0218 AH-03127S Conventional fire alarm bell Conventional type A electronic sounder Notes: Meets the requirements of EN54-3: 2001 at the following tones: 1-Alternating tones 800/970Hz at 2Hz 2-Sweeping 800/970Hz at 7Hz Conventional Type A electronic sounder beacon Notes: 1. Meets the requirements of EN54-3: 2001 at the following tones: 1-Alternating Tones 800/970Hz at 2Hz 2-Sweeping 800/970Hz at 7Hz 2. The beacon functionality is not included within the scope of approval. LPCB Ref. No. 506e/01 506e/02

AH-03127-BS

506e/03

344

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES

Hosiden Besson Limited


St Joseph's Close Trading Estate, St Joseph's Close, Hove, East Sussex BN3 7EZ, United Kingdom Tel: +44 (0)1273 860000 Fax: +44 (0)1273 777501 E-mail: info@hbl.co.uk Website: www.hbl.co.uk
Certificate No: 715a-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificated Products Banshee MT Sounder (892 shallow base version and deep base version) Notes: 1) Certified to EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Sound 13 Banshee HF (and Bedlam) Sound 19 Slow Whoop (Dutch) Sound 20 DIN Klung (German) Sound 21 AFNOR (French) 2) Approved as Type A when used with shallow base (892) & Type B when used with deep base (893) 3) Approved voltage range 10-28V Conventional 32 tone sounder with 1 Watt Xenon beacon (shallow & deep bases) Notes: 1) Suitable for Type A indoor application when used with shallow base & deep base 2) Approved with body moulding & lens colour variations 3) Approved at 12 & 24 VDC 4) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 32 tone sounder with LED beacon & deep bases) Notes: 1) Suitable for Type A indoor application when used with shallow or deep base 2) Suitable for Type B outdoor application when used with deep base & sealing gasket 3) Approved at 12 & 24 VDC 4) Approved with body moulding & lens colour variations 5) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 32 Tone Sounder Notes: 1) Suitable for Type A indoor application only 2) Approved at 12 & 24 VDC 3) Approved with body moulding colour variations 4) To be used in conjunction with a suitable detector when supplied without cover 5) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 32 tone sounder with bipolar supply input (shallow & deep bases) Notes: 1) Suitable for Type A indoor application when used with shallow or deep base 2) Suitable for Type B outdoor application when used with deep base & sealing gasket 3) Approved at 12 & 24 VDC 4) Approved with body moulding colour variations 5) Meets requirements of EN 54-3: 2001 with the following tones: Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9Hz Sound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9Hz LPCB Ref. No. 715a/01

Flashtone Banshee MT

715a/02

LED Flashtone Banshee MT

715a/03

Wafer MT

715a/04

Bipolar Banshee MT

715a/05

12 Sep 2011

345

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products Sound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3Hz Sound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeat Sound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeat Sound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms Conventional 2 tone sounder Notes: 1) Suitable for Type A indoor application only 2) Approved with body moulding colour variations 3) Meets requirements of EN 54-3: 2001 with the following tones: Sound 1 Continuous 850 Hz Sound 2 Fast Sweep 800 - 950 Hz @ 9 Hz LPCB Ref. No.

FM Bedroom

715a/06

Bases: Shallow base (various colour options) Deep base (various colour options)

KAC Alarm Company Limited


KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom Tel: +44 (0)1527 406655 Fax: +44 (0)1527 406677 E-mail: sales@kac.co.uk OR marketing@kac.co.uk Website: www.kac.co.uk
Certificate No: 166c to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificate No: 166d to EN 54-3 + A1:2002 + A2: 2006 and EN 54-17: 2005 Certificated Products EMA1224B4R EMA1224B4W SOU-SSR-4 SOU-SSW-4 SOU-LPR-4 SOU-LPW-4 SOU-SR-4 SOU-SW-4 WMSST-xx-Pww 4 Tone wall mounting conventional sounder, red. Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone wall mounting conventional sounder, white Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone surface mounting conventional sounder with sealing kit, red Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone surface mounting conventional sounder with sealing kit, white Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone low profile mounting conventional sounder, red Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone low profile mounting conventional sounder, white. Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone surface mounting conventional sounder, red. Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC 4 Tone surface mounting conventional sounder, white. Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Intelligent wall mounted sounder strobe Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. X x indicates body colour. R =Red, W =Bright White, P =Pure White 3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear 4. Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532 VDC Intelligent wall mounted sounder Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. xx indicates body colour. RR =Red, WW =Bright White, PW =Pure White 3. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC LPCB Ref. No. 166c/01 166c/02 166c/03 166c/04 166c/05 166c/06 166c/07 166c/08 166c/09

WMSOU-xx-Pww

166c/10

346

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products IBSST-xx-Pww Intelligent integrated detector base sounder strobe Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. X x indicates body colour. R =Red, W =Bright White, D =Detector White, K =Black, P =Pure White 3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear 4. Meets the requirements of EN54-3 for all tones at voltage range 15-32 VDC with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only Intelligent integrated detector base sounder Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. xx indicates body colour. RR =Red, WW =Bright White, DD =Detector White, KK =Black, PW =Pure White 3. Meets the requirements of EN54-3 for all tones at voltage range 15-32 VDC with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only Conventional Type A wall mounted sounder (red) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Conventional Type A wall mounted sounder (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Conventional Type A sounder base (white) Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Conventional Type A sounder base (white), supplied with red lid Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Conventional Type A sounder base (white), supplied with white lid Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Conventional Type A wall mounted sounder Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1. ww (Range 0-99 even numbers only indicates the ommunication software protocol 2. X x indicates body colour. R =Red, W =Bright White, P =Pure White 3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear 4. Meets the requirements of EN54-3 for all tones and output levels at voltage range 1528v Intelligent wall mounted sounder with short circuit isolator Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol 2. xx indicates body colour. RR =Red, WW =Bright White, PW =Pure White 3. Meets the requirements of EN54-3 for all tones and output levels at voltage range 1528v Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol 2. X x indicates body colour. R =Red, W =Bright White, D =Detector White, K =Black, P =Pure White 3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear 4. Meets the requirements of EN54-3 for all tones at voltage range 15-28v with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only Intelligent integrated detector base sounder with short circuit isolator Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol 2. xx indicates body colour. RR =Red, WW =Bright White, DD =Detector White, KK =Black, PW =Pure White 3. Meets the requirements of EN54-3 for all tones at voltage range 15-28v with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only Conventional Type A wall mounted sounder strobe (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10LPCB Ref. No. 166c/11

IBSOU-xx-Pww

166c/12

EMA1224FR

166c/15

EMA1224FW DBS-4 DBS-R-4 DBS-W-4 DBS1224B4W WMSST-xx-Pww

166c/16 166c/27 166c/28 166c/29 166c/30 166d/01

WMSOU-xx-Pww

166d/02

IBSST-xx-Pww

166d/03

IBSOU-xx-Pww

166d/04

EMA12Fxxxx

166c/31

12 Sep 2011

347

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 14 VDC 2) XX xx indicates body colour. RS =Red, WS =White 3) xx XX indicates lens colour. SR =Red, SA =Amber, SC =Clear Conventional Type A wall mounted sounder strobe (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 2127 VDC 2) XX xx indicates body colour. RS =Red, WS =White 3) xx XX indicates lens colour. S -=Red and Amber supplied, SR =Red, SA =Amber, SB =Blue Conventional Type A wall mounted sounder strobe (white) (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 1014 VDC 2) XX Wx indicates base type. LP =ELPBR/W, - S =ESBR/W, SS =ESBRS/WS. 3) xxW X indicates lens colour. R =Red, A =Amber, B =Blue, G =Green Conventional Type A wall mounted sounder strobe (red) (ELPBR/W, ESBR/W and ESBRS/WS bases) Notes: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 2127 VDC 2) XX Rx indicates base type. LP =ELPBR/W, - S =ESBR/W, SS =ESBRS/WS. 3) xxR X indicates lens colour. R =Red, A =Amber, B =Blue Intelligent wall mounted sounder strobe with short circuit isolator. Note: 1. Meets the requirements of EN54-3 for all tones and output levels at voltage range 1528v Intelligent wall mounted sounder strobe. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC Intelligent integrated detector base sounder strobe Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. Intelligent integrated detector base sounder strobe with short circuit isolator Note: 1. Meets the requirements of EN54-3 for all tones at voltage range 15-28v with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only EMA1224B4R-D 4 Tone Type A conventional wall mounting sounder, red Note: Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 4 Tone Type A conventional wall mounting sounder, white Note: Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 4 Tone Type A conventional ceiling mounting sounder, white Note: Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 166c/37 LPCB Ref. No.

EMA24Fxxxx

166c/32

SST-xxWx-14

166c/33

SST-xxRx-14

166c/34

WMSST-RR-P30

166d/07

WMSST-RR-P29 IBSST-DR-P29

166c/35 166c/36

IBSST-DR-P30

166d/08

EMA1224B4W-D

166c/38

DBS1224B4W-D

166c/40

348

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Bases: ELPBR/W Low profile base IP21C, red or white ESBR/W Standard base IP54, red or white ESBRS/WS Standard base and IP66 sealing kit, red or white

Morley-IAS Fire Systems By Honeywell


Charles Avenue, Burgess Hill, West Sussex RH15 9UF Tel: +44 (0)1444 235556 Fax: +44 (0)1444 254410 E-mail: sales@morleyias.co.uk Website: www.morley-ias.co.uk

Certificate No: 166c to EN 54-3: 2001 Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97 Certificated Products MI-WSDB-X-XX Intelligent wall mounted sounder strobe Notes: 1) x-xx indicates body colour. R=Red, W=Detector White 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent wall mounted sounder Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe Notes: 1) x-xx indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent integrated detector base sounder Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1) x-xx indicates body colour. R=Red, W=Detector White 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent wall mounted sounder with short circuit isolator Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1) x-xx indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear Intelligent integrated detector base sounder with short circuit Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black LPCB Ref. No. 166c/09

MI-WSD-X MI-IBSDB-X-XX

166c/10 166c/11

MI-IBSD-X MI-WSDB-X-XX-I

166c/12 166d/01

MI-WSD-X-1 MI-IBSDB-X-XX-I

166d/02 166d/03

MI-IBSD-X-I

166d/04

Multron Systems Pte Ltd


217 Kallang Bahru, Multron Building, Singapore 339 347, Singapore Tel: +65 6743 2555 / 6395 6868 Fax: +65 6743 2777 / 6395 6869 E-mail: info@multron.com Website: www.multron.com
Certificate No: 548e-(cl-6) to EN 54-3:2001 + A1:2002 + A2:2006 Certificated Products AVD-C403 AVD-A403 Conventional sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) Intelligent sounder strobe Notes: Meets the requirements of EN 54-3: 2001 at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) LPCB Ref. No. 548e/01 548e/02

12 Sep 2011

349

PART 1: SECTION 7
ALARM WARNING DEVICES

Notifier by Honeywell
Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230230 Fax: +44 (0)1444 230689 E-mail: sales@notifierfiresystems.co.uk Website: www.notifierfiresystems.co.uk
Certificate No: 166c to EN 54-3: 2001 + A1:2002 + A2:2006 Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97 Certificated Products NS4/R 4 Tone wall mounting conventional sounder (red) Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v 4 Tone wall mounting conventional sounder (white) Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v Intelligent wall mounted sounder strobe Notes: 1) x/x indicates body colour. R=Red, W=Detector White 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent wall mounted sounder Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe Notes: 1) x/x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent integrated detector base sounder Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 4 Tone Type A conventional wall mounting sounder, red Note: Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 4 Tone Type A conventional wall mounting sounder, white Note: Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 4 Tone Type A conventional ceiling mounting sounder, white Note: Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1) x/x indicates body colour. R=Red, W=Detector White 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent wall mounted sounder with short circuit isolator Note: 1) x indicates body colour. R=Red, W=Detector White Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1) x/x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black LPCB Ref. No. 166c/01

NSR4/W

166c/02

AWSB32/X/X

166c/09

AWS32/X ABSB32/X/X

166c/10 166c/11

ABS32/X NS3D/R

166c/12 166c/37

NS3D/W

166c/38

NBS3D

166c/40

AWSB32/X/X-I

166d/01

AWS32/X-I ABSB32/X/X-I

166d/02 166d/03

350

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products ABS32/X-I 2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent integrated detector base sounder with short circuit isolator Note: 1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black LPCB Ref. No. 166d/04

OG Elektronik
Sanayi Mah., 636 Sok., Erol Apt. 11/3, Antalya, Turkey Tel: +9 0242 344 2500 Fax: +9 0242 344 2120 E-mail: info@og.com.tr; ahmet@og.com.tr Website: www.og.com.tr
Certificate No: 928g-(cl-1) to 54-3: 2001 + A1: 2002 and EN 54 -17: 2005 Certificated Products FF LS200 Analogue addressable Type A sounder with short circuit isolator Notes 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady LPCB Ref. No. 928g/01

Protec Fire Detection plc


Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 Fax: +44 (0)1282 717273 E-mail: sales@protec.co.uk Website: www.protec.co.uk
Certificate No: 201n to EN 54-3: 2001 Certificated Products 6000/SSR2 Analogue addressable Type A/B sounder - red (Shallow and N29-982-75 base) Notes: 1) The device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones: 1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz Analogue addressable Type A/B sounder - white (Shallow and N29-982-75 base) Notes: 1) This device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones: 1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz Analogue addressable Type A/B sounder - red (Shallow and N29-982-75 base) Notes: 1) This device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones: 1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz 3 - Dutch whoop - 500 / 1500 Hz Analogue addressable Type A/B sounder - white (Shallow and N29-982-75 base) Notes: 1) This device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones: 1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz 3 - Dutch whoop - 500 / 1500 Hz LPCB Ref. No. 201n/01

6000/SSW2

201n/02

6000/SSR2/NL

201n/03

6000/SSW2/NL

201n/04

Bases: N29-982-75 Deep base Shallow base

12 Sep 2011

351

PART 1: SECTION 7
ALARM WARNING DEVICES

SHIELD FIRE, SAFETY & SECURITY LTD


28th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United Kingdom Tel: +44 161 257 2541 Fax: +44 161 225 8817 E-mail: dorota@xportsales.com Website: www.xportsales.com
Certificate No: 548e to EN 54-3: 2001 Certificated Products S-A491 Intelligent sounder strobe Notes: Meets the requirements of EN 54-3: 2001at the following tones: Mode I (for pre alarm): 0.61Hz (430ms on / 1200ms off) Mode II (for fire alarm): 1.30Hz (430ms on / 340ms off) Conventional sounder strobe Notes: Meets the requirements of EN 54-3: 2001at the following tones: Fixed tone: 1.35Hz (400ms on / 340ms off) LPCB Ref. No. 548e/02

S-C481

548e/01

Siemens Switzerland Limited, Building Technologies Division


International Headquarters, Fire Safety & Security Products, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 Fax: +41 (0) 41 724 35 22
Certificate No: 126ar-(cl-1) to EN54-3: 2001+A1: 2002+A2: 2006 and EN54-17: 2005 Certificate No: 531g-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Sounders
Certificated Products FDS229-R Analogue addressable sounder beacon (Red) with short circuit isolator (FDB221, FDB221-AA, FDB291 and FDB293) 1) Meets the requirements of EN 54-3 at the following tones: Continuous 970Hz 1s Intermittent 950Hz 1s Sweep-down 1200Hz-500Hz 3.5s Slow-whoop sweep-up, 0.5s linear 500Hz-1200Hz Pulse-tone 150ms on 100ms off 500Hz Intermittent 150ms on 600ms off 500Hz Continuous 500Hz Alternating 0.1s on 0.4s off 560Hz/440Hz Intermittent 600ms on 650ms off 420Hz 3.75s Slow-whoop sweep-up, 0.25s linear 500Hz-1200Hz Intermittent 0.5s on 0.5s off 1s pause 970Hz Analogue addressable sounder beacon (Amber) with short circuit isolator (FDB221, FDB221-AA, FDB291 and FDB293) 1) Meets the requirements of EN 54-3 at the following tones: Continuous 970Hz 1s Intermittent 950Hz 1s Sweep-down 1200Hz-500Hz 3.5s Slow-whoop sweep-up, 0.5s linear 500Hz-1200Hz Pulse-tone 150ms on 100ms off 500Hz Intermittent 150ms on 600ms off 500Hz Continuous 500Hz Alternating 0.1s on 0.4s off 560Hz/440Hz Intermittent 600ms on 650ms off 420Hz 3.75s Slow-whoop sweep-up, 0.25s linear 500Hz-1200Hz Intermittent 0.5s on 0.5s off 1s pause 970Hz Analogue addressable Type A base sounder LPCB Ref. No. 126ar/01

FDS229-A

126ar/02

DBS720

531g/01

Notes: 1) Meets the requirements of EN 54-3 with the following tones: Tone 1 Continuous 970Hz Tone 2 Intermittent 950Hz; 1s on,1s off

352

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products Tone 3 Sweep down 1200Hz?500Hz at 1Hz Tone 4 Slow whoop 500Hz?1200Hz over 3.5s, 0.5s off Tone 5 Pulse tone 500Hz; 0.15s on, 0.1s off Tone 6 Intermittent 500Hz; 0.15s on, 0.6s off Tone 7 Continuous 500Hz Tone 8 Alternating 560Hz 0.1s/440Hz 0.4s Tone 9 Intermittent 420Hz; 0.6s on, 0.65s off Tone 10 Slow whoop - 500?1200Hz over 3.75s, 0.25s off Tone 11 Intermittent 970Hz; 3 pulses 0.5s on, 0.5s off repeated after 1.5s 2) Approved only when used with detector devices OP720, OH720, HI720 or HI722 LPCB Ref. No.

Accessories: FDB221 FDB221-AA FDB291 FDB293 detector base detector base, addressed with 2 micro-terminals base attachment base attachment wet

Sterling Safety Systems


Unit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United Kingdom Tel: +44(0)1926485282 Fax: +44(0)1926485090 E-mail: info@sterlingsafety.co.uk Website: www.sterlingsafety.co.uk
Certificate No: 928g to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products HFI-WSR-01 Analogue addressable Type A sounder with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone 990Hz, steady LPCB Ref. No. 928g/01

System Sensor Europe


KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom Tel: +44 (0)1527 406700 Fax: +44 (0)1527 406699 Website: www.systemsensoreurope.com
Certificate No: 166c to EN 54-3: 2001 Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97 Certificated Products WMSST-XX-P01 Intelligent wall mounted sounder strobe Notes: 1) xx indicates body colour. R=Red, W=Bright White 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Intelligent wall mounted sounder Note: 1) xx indicates body colour. RR=Red, WW=Bright White Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Intelligent integrated detector base sounder strobe Notes: 1) xx indicates body colour. R=Red, W=Bright White, D=Detector White, K=Black LPCB Ref. No. 166c/09

WMSOU-XX-P01

166c/10

IBSST-XX-P01

166c/11

12 Sep 2011

353

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. Intelligent integrated detector base sounder Note: 1) xx indicates body colour. RR=Red, WW=Bright White, DD=Detector White, KK=Black Intelligent non-integrated detector base sounder strobe Notes: 1) xx indicates body colour. R=Red, W=Bright White 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Intelligent non-integrated detector base sounder Note: 1) xx indicates body colour. RR=Red, WW=Bright White Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. Intelligent wall mounted sounder strobe with short circuit isolator Notes: 1) xx indicates body colour. R=Red, W=Bright White 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Intelligent wall mounted sounder with short circuit isolator Note: 1) xx indicates body colour. RR=Red, WW=Bright White. Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Intelligent integrated detector base sounder strobe with short circuit isolator Notes: 1) xx indicates body colour. R=Red, W=Bright White, D=Detector White, K=Black 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent integrated detector base sounder with short circuit isolator Note: 1) xx indicates body colour. RR=Red, WW=Bright White, DD=Detector White, KK=Black Meets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent non-integrated detector base sounder strobe with short circuit isolator Notes: 1) xx indicates body colour. R=Red, W=Bright White 2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear Meets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent non-integrated detector base sounder with short circuit isolator Note: 1) xx indicates body colour. RR=Red, WW=Bright White Meets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent wall mounted sounder strobe Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-28v. Intelligent integrated detector base sounder strobe. Notes: 1) Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only. Intelligent wall mounted sounder strobe Meets the requirements of EN54-3 for all tones and output levels at voltage range 1532v. Intelligent integrated detector base sounder strobe. Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only. LPCB Ref. No.

IBSOU-XX-P01 DBSST-XX-P01-C

166c/12 166c/13

DBSOU-XX-P01-C

166c/14

WMSST-XX-P02

166d/01

WMSOU-XX-P02

166d/02

IBSST-XX-P02

166d/03

IBSOU-XX-P02

166d/04

DBSST-XX-P02-C

166d/05

DBSOU-XX-P02-C

166d/06

WMSST-RP-P30

166d/07

IBSST-DR-P30

166d/08

WMSST-RR-P29 IBSST-DR-P29

166c/35 166c/36

354

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES

Teledata S.r.l.
Via Giulietti 8, Milan 20132, Italy Tel: +39 02-27201352 Fax: +39 02-2593704 E-mail: info@teledata-i.com Website: www.teledate-i.com
Certificate No: 928g-(cl-6) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005 Certificated Products FDS100 Analogue addressable Type A sounder with short circuit isolator Notes: 1) Meets the requirements of EN 54-3 at the following tone settings: Dual tone: 990 and 650Hz, 2Hz (250ms-250ms) Pulsed tone: 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone: 990Hz, steady LPCB Ref. No. 928g/01

Texecom Ltd
Bradwood Court, St Crispin Way, Haslingden, Lancashire BB4 4PW, United Kingdom Tel: +44 (0)1706 220460 Fax: +44 (0)1706 230692 E-mail: sales@texe.com Website: http://www.texe.com
Certificate No: 717a to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificated Products PSS-0068 Conventional Sounder with LED Strobe (Red Head / Red Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe (Red Head / White Base) PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe (Amber Head / Red Base) PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe (Amber Head / White Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder (Red) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder (White) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) LPCB Ref. No. 717a/01

PSS-0079

717a/02

PSS-0073

717a/03

PSS-0080

717a/04

PSS-0084

717a/05

PSS-0089

717a/06

12 Sep 2011

355

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products Notes: 1. 2. PBS-0003 LPCB Ref. No. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 717a/07

Universal base sounder (White) Notes: 1.

Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 717a/08

PBS-0009

Universal base sounder (Cream) Notes: 1. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe Common Operation (Red Head / Red Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with Red LED Strobe Common Operation (Clear Lens / White Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe Common Operation (Amber Head / Red Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with Red LED Strobe (Clear Lens / White Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Universal base sounder (Red) Notes: 1. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe Common Operation (Red Head / White Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13 Conventional Sounder with LED Strobe Common Operation (Amber Head / White Base) (PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases) Notes: 1. The above sounder is Type A when used the with the shallow base & Type B when used with the deep base only 2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSC-0045

717a/10

PSC-0051

717a/11

PSC-0054

717a/12

PSC-0055

717a/13

PBS-0015

717a/14

PSC-0062

717a/16

PSC-0063

717a/17

Bases:

356

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES
PSO-0001 Shallow base (red) PSO-0006 Shallow base (white) PSO-0003 Deep base (red) PSO-0007 Deep base (white)

Thorn Security Limited, trading as Tyco Safety Products


Dunhams Lane, Letchworth SG6 1BE, United Kingdom Tel: +44 (0)1462 667700 Fax: +44 (0)1462 667777 E-mail: mashbury@tycoint.com Website: www.tycosafetyproducts-europe.com
Certificate No: 681g-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificate No: 378e to EN 54-3: 2001 & EN 54-17: 2005 Certificated Products 802SB Analogue addressable type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Fast Sweep Dutch Slow Whoop 500Hz to 1200Hz Temporal 3 880Hz Conventional type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Conventional type A diode sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Conventional type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Conventional type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Analogue addressable type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Analogue addressable type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Analogue addressable type A sounder base Notes: 1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz Symphoni MX addressable loop powered Type A sounder (red) with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type A sounder (white) with short circuit isolator LPCB Ref. No. 681g/01

601SB

681g/02

601SBD

681g/03

602SB

681g/04

602SBD

681g/05

901SB

681g/06

912SB

681g/07

812SB

681g/08

LPSY800-R LPSY800-W

378e/01 378e/02

12 Sep 2011

357

PART 1: SECTION 7
ALARM WARNING DEVICES
Certificated Products Notes: 1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type B sounder (red) with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type A sounder beacon (red) with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type A sounder beacon (white) with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. Symphoni MX addressable loop powered Type B sounder beacon (red) with short circuit isolator Notes: 1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9. LPCB Ref. No. 378e/03 378e/04

LPSY865 LPAV800-R

LPAV800-W

378e/05

LPAV865

378e/06

UTC Fire & Security Inc. Trading as Edwards Systems Technology


8985 Town Center Parkway, Bradenton, Florida FL34202, United States Tel: 941 739-42228 Website: www.fs.utc.com
Certificate No: 262w to EN 54-3: 2001 + A1: 2002 + A2: 2006 Certificated Products G1x-HD-E Genesis Temporal Horn Notes: 1. Approved with back boxes G1B-MP and 27193-16 2. Meets the requirements of EN 54-3 at all volumes and the following tones:Continuous 3200HZ (interrupted at 40Hz) Temporal 3200Hz (interrupted at 40Hz); 2 pulses 0.5s on / 0.5s off, 1 pulse 0.5s on / 1.5s off, repeat. 3. x denotes housing colours Blank = White housing R = Red housing F = White housing with Fire Marking RF = Red housing with Fire Marking. Genesis Temporal Horn / Strobe Notes: 1. Approved with back boxes G1B-MP and 27193-16 2. Meets the requirements of EN 54-3 at all volumes and the following tones:Continuous 3200HZ (interrupted at 40Hz) Temporal 3200Hz (interrupted at 40Hz); 2 pulses 0.5s on / 0.5s off, 1 pulse 0.5s on / 1.5s off, repeat. 3. x denotes housing colours Blank = White housing R = Red housing F = White housing with Fire Marking RF = Red housing with Fire Marking. LPCB Ref. No. 262w/02

G1x-HDVM-E

262w/03

Ancillaries G1B-MP Back box G1 series, white 27193-16 Back box, surface white

358

12 Sep 2011

PART 1: SECTION 7
ALARM WARNING DEVICES

Vimpex Limited
Star Lane, Great Wakering, Essex SS3 0PJ, United Kingdom Tel: +44 (0) 1702 216999 Fax: +44 (0) 1702 216699 E-mail: sales@vimpex.co.uk Website: www.vimpex.co.uk
Certificate No: 692a to EN 54-3: 2001 Certificated Products MBF-6EV-24 MBF-8EV MBA-6 + BBX.4 MBA-8 + BBX.4 6" (150mm) 24Vdc fire alarm bell with aluminium gong 8" (200mm) 24Vdc fire alarm bell with aluminium gong 6" (150mm) fire alarm bell with aluminium gong complete with back box 8" (200mm) fire alarm bell with aluminium gong complete with back box LPCB Ref. No. 692a/01 692a/02 692a/04 692a/05

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 692a-(cl-1) to EN 54-3: 2001 + A1: 2002 Certificated Products ZTB8B - 41-005 ZTB6B/WP - 41-003A ZTB8B/WP - 41-006 8" (200mm) 24Vdc fire alarm bell with aluminimum gong 6" (150mm) fire alarm bell with aluminium gong complete with back box. 8" (200mm) fire alarm bell with aluminium gong complete with back box. LPCB Ref. No. 692a/02 692a/04 692a/05

12 Sep 2011

359

PART 1: SECTION 8
FIRE RESISTANT CABLES This section lists fire resistant cables for use in fire safety, fire detection and fire alarm systems and other applications where specifications require cables with specific performance in the event of a fire. BS 5839-1:2002+A2:2008 Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance BS 5839-1:2002+A2:2008 includes requirements for fire resistant cables for fire detection and alarm systems. It calls for Standard and Enhanced fire resistant cables and defines the requirements for these in Clause 26.2. These cables have to comply with BS EN 60702-1 (with a polymeric sheath), BS 7629 or BS 7846, and:Standard fire resisting cables also have to: a) achieve Class PH30 when tested in accordance with EN 50200:2006. and b) maintain circuit integrity when exposed to a special flame / mechanical shock / water spray sequence equivalent to achieving a duration of 30 minutes when tested in accordance with BS EN 50200:2006 Annex E. - Enhanced fire resisting cables also have to: a) achieve a 120 minute survival when tested in accordance with EN 50200:2006. and b) maintain circuit integrity when exposed to a special flame / mechanical shock / water spray sequence equivalent to achieving a duration of 120 minutes when tested in accordance with BS 8434-2:2003+A2:2009. Cables complying with these requirements are listed as Standard or Enhanced under BS 5839-1, Clause 26.2. Building Regulations 2000 - Fire Safety - Approved Document B The Building Regulations 2000 - Fire Safety - Approved Document B - Volume 2 - Buildings other than dwelling houses (Amended 2007) defines a protected power circuit to be able to continue to function during a fire. A protected circuit for operation of equipment in the event of fire should consist of a cable meeting at least the requirements of PH30 when tested in accordance with EN 50200. Larger or complex buildings may require fire protection systems to operate for extended periods during fire and guidance on such systems is given in BS 5839-1, BS 5266-1 and BS 7346-6. Additional provisions for applications not covered by the above may be given in BS 8519:2010. Other Standards Used The other standards and test methods currently used for certification are listed below. This list includes some "withdrawn" standards. Where possible, these will be replaced by the superseding standards when certificates are renewed. However, where withdrawn standards are called up by current standards, certification to the withdrawn standard may need to be maintained until the calling standard is amended to remove the reference: - BS 6207-1:1995 Mineral insulated cables with rated voltage not exceeding 750V - BS 6387:1994 Performance requirements for cables required to maintain circuit integrity under fire conditions - BS 6425-1:1990 Gases evolved during combustion of electric cables. Part 1: Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables - BS 7346-6:2005 Components for smoke and heat control systems - Part 6: Specification for cable systems - BS 7622-2:1993 Measurement of smoke density of electric cables burning under defined conditions - BS 7629-1:1997 Thermosetting insulated cables with limited circuit integrity when affected by fire. Part 1: Multicore cables. - BS 7629-1:1997 (Incorporating Amendment Nos.1 and 2) Thermosetting insulated cables with limited circuit integrity when affected by fire. Part 1: Multicore cables (The provisions introduced by amendment No.1: 2004 are effective from 1st April 2004) - BS 7629-1:2008 Electric cables - Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire Part 1: Multicore and multipair cables - BS 7846:2000 Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire.

360

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES - BS 7846:2000 (Incorporating Amendment No.1) Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire. (The provisions introduced by amendment No.1: 2004 are affective from 1st April 2004) - BS 7846:2000 (Incorporating Amendment Nos.1 and 2) Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire. - BS 7846:2009 Electric cables - Thermosetting insulated, armoured, fire - resistant cables of rated voltage 600/1 000 V, having low emission of smoke and corrosive gases when affected by fire - Specification - BS 8434-1:2003 Method of test for assessment of the fire integrity of electric cables - Part 1: test for unprotected small cables for use in emergency circuits - BS EN 50200 with addition of water spray - BS 8434-2:2003+A2:2009 Method of test for assessment of the fire integrity of electric cables - Part 2: test for unprotected small cables for use in emergency circuits- BS EN 50200 with a 930C flame and with water spray - BS 8491:2008 Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and other certain active fire safety systems - BS 8519:2010 Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications - Code of practice - EN 50200:2000 Method of test for resistance to fire of unprotected small cables for use in emergency circuits - EN 50200:2006 Method of test for resistance to fire of unprotected small cables for use in emergency circuits - EN 50266:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically mounted bunched wires or cables - EN 50267-2-1:1999 Common test method for cables under fire conditions- tests on gases evolved during combustion of materials from cables - procedures - Determination of the amount of halogen acid gas - EN 50267-2-3:1999 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Procedure 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity - EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions - EN 60332-3:2009 Tests on electric and optical fibre cables under fire conditions - Part 3: Test for vertical flame spread of vertically mounted bunched wires or cables - EN 60702-1:2002 Mineral insulated cables and their terminations with rated voltage not exceeding 750V - EN 61034-2: 2005 Measurement of smoke density of cables burning under defined conditions - IEC 331:1970 Fire resisting characteristics of electric cables - IEC 60754-1:1994 Tests on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas - IEC 60754-2:1991 Tests on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity - IEC 60331-21:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 21 Procedure and requirements - Cables of rated voltage up to and including 0,6/1,0kV - IEC 60331-23:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 23 Procedure and requirements - Electric data cables - IEC 60331-25:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 25 Procedure and requirements - Optical fibre cables - IEC 60331-31:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 31 Procedure and requirements for fire with shock - Cables of rated voltage up to and including 0,6/1,0kV - IEC 60332-3:2000 Tests on electric cables under fire conditions - Part 3: Tests on bunched wires or cables - IEC 61034-2:2005 Measurement of smoke density of cables burning under defined conditions Notes: 1) The rated voltages Uo/U recognised for BS 6387:1994 are, 300/500V and 450/750V, and for BS 7629 are 300/500V, where Uo is the power-frequency voltage to earth and U is the power-frequency voltage between conductors. 2) Testing of single core cable to BS 6387:1994 is not recognised by the standard. This is because it requires the cable to have at least two metallic elements. Therefore LPCB approval of single core cable is based on the cable being tested in a stainless steel conduit. 3) MICC Cables approved to BS 5839-1:2002+A2:2008 Clause 26.2 must be sheathed with an overall polymeric covering.

12 Sep 2011

361

PART 1: SECTION 8
FIRE RESISTANT CABLES 4) BS EN 50200:2006 Annex E and BS 8434-2:2003+A2:2009 provide methods of test that meet the requirements for a special flame / mechanical shock / water spray sequences described in BS 58391:2002+A2:2008, Clause 26.2 d) and e), respectively.

2M KABLO SAN. ve TIC. A.S.


Sanayi Mahallesi, 1678 Sokak No: 3, 34511 Esenyurt, Istanbul, Turkey Tel: +90 212 672 7314 Fax: +90 212 672 7312 E-mail: sales@2mkab.com Website: www.2mkab.com
Certificate No: 711a to BS 6387: 1994 and BS EN 50200: 2006 Class PH120

FireKab BMK-SH FE 180


Nominal csa of conductors (mm2) 1.0 (1) 1.5 (1) 2.5 (1) Uo/U 300/500 V Note: 1) Solid conductor only. Certificate No: 711b to BS EN 50200: 2006 Class PH120 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3, 4, 5 & 7 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH120 Class PH120 Class PH120 LPCB Ref. No. 711a/01

FireKab JE-H(ST)H BD FE 180 E30-E90


Nominal csa of conductors (mm) 0.50(1, 2) 1.50(1) Uo/U 175/300V Notes: 1) Solid conductor only. 2) External diameter of this conductor is 0.80mm. Certificate No: 711c to BS 6387: 1994 and BS EN 50200: 2006 Class PH30 Core Construction (excluding earth wire) 1, 2, 4, 8, & 12 pairs 1 & 2 pairs BS EN 50200 Class PH120 Class PH120 LPCB Ref. No. 711b/01

FireKab NGF FE 180 PH30


Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) Uo/U 300/500V Notes: 1) Solid conductor only. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH30 Class PH30 Class PH30 LPCB Ref. No. 711c/01

362

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES

AC Electrical Wholesalers Ltd


Cobham Road, Ferndowne Industrial Estate, Wimborne, Dorset BH21 7SJ, United Kingdom Tel: +44 (0)1202 851800 Fax: +44 (0)1202 851818 Website: www.ac-electrical.com
Certificate No: 682a to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), BS EN 50200:2006 Class PH120, BS 8434-1:2003 30min and BS 5839-1:2002 Clause 26.2d

NoBurn Platinum
Nominal csa of conductor (mm2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 (Incorporating Amendments No.1 & 2) Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS 84341 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No. 682a/01

Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), the NoBurn Platinum cables listed met the requirements of smoke density of BS EN 50268-2:2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-21:1999. 4) The duration of 30min when tested in accordance with BS 8434-1:2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d of BS 5839-1:2002. 5) The NoBurn Platinum cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos.1 and 2), met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS 8434-1:2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.

AEI Cables Limited


Birtley, Chester-le-Street, Co. Durham DH3 2RA, United Kingdom Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail: sales@aeicables.co.uk Website: www.aeicables.co.uk
Certificate No: 221b to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2: 2000

Firetec Power LSZH Cable


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10.0 16 Uo/U 450/750V Note: 1) The Firetec Power LSZH cable also met Category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 (see note 1) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 50268-2 >60% >60% >60% >60% >60% >60% >60% LPCB Ref. No. 221b/02

12 Sep 2011

363

PART 1: SECTION 8
FIRE RESISTANT CABLES
Certificate No: 221c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

Firetec Single Core LSZH


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 185 240 300 400 630 800 1000 Uo/U 600/1000V Note 1: Note 2: Note 3: Note 4: Note 5: Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. Note 6: To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. Note 7: To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. Note 8: These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Note 9: The Firetec Single Core LSZH cable also met IEC 60331-21: 1999 when installed in steel conduit. Note 10: Only Clause 10 of BS 6387 was conducted. Certificate No: 221e to BS 7629-1: 2008, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E & BS 5839-1: 2002+A2:2008 Clause 26.2d Core Construction (See note 1) One One One One One One One One One One One One One One One One One One One One BS 6387 (see notes 2-4) C, W, Z(5) C, W, Z(5) C, W, Z(5) C, W, Z(5) C, W, Z(5) C, W, Z(5) C, W, Z(6,7) C, W, Z(6,7) C, W, Z(6,7) C(7) C(7) C(7) C(7) C(7) C(7) C(7) Complies(10) Complies(10) Complies(10) Complies(10) BS EN 50267-1-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl IEC 60331-21 (see notes 8 & 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 221c/01

Firetec Standard Multicore LSZH


Nominal csa of conductor (mm2) 1.5(1) 2.5
(1)

Core Construction (excluding drain wire and earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4

BS 7629-1

BS EN 50200 Class PH120 Class PH120 Class PH120

BS EN 50200 Annex E 30min(4) 30min


(4)

BS 5839-1 Clause 26.2 Standard(5) Standard


(5)

LPCB Ref. No. 221e/01

Complies(3) Complies
(3)

4.0(2)

Complies(3)

30min(4)

Standard(5)

Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the Firetec Standard Multicore LSZH cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

364

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 5) The Firetec Standard Multicore LSZH cables listed conform to BS 7629-1: 2008, met class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 221f to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

Firetec Enhanced Multicore LSZH


Nominal csa of conductor (mm2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the Firetec Enhanced Multicore LSZH cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2: 2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. 5) The Firetec Enhanced Multicore LSZH cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS 8434-2 120min(4) 120min(4) 120min(4) 120min(4) BS 5839-1 Clause 26.2 Enhanced(5) Enhanced(5) Enhanced(5) Enhanced(5) LPCB Ref. No. 221f/01

Certificate No: 221h to BS 6387: 1994 and BS EN 60702-1: 2002

Mineral Insulated Cable (light duty)


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 Uo/U 300/500 V Note: 1. The above range is certified in both Bare and Served constructions. Certificate No: 221h to BS 6387: 1994 and BS EN 60702-1: 2002 Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies LPCB Ref. No. 221h/01

Mineral Insulated Cable (single core)


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 Core Construction One One One One One One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 221h/02

12 Sep 2011

365

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm2) 120 150 185 240 300 400 Uo 750V Notes: 1) The above range is certified in both Bare and Served constructions. 2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Certificate No: 221h to BS 6387: 1994 and BS EN 60702-1: 2002 Core Construction One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies LPCB Ref. No.

Mineral Insulated Cable (heavy duty)


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 Uo/U 450/750V Core Construction 2, 3, 4, 7, 12 & 19 2, 3, 4, 7 & 12 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 221h/03

Notes: 1) The above range is certified in both bare and served constructions. 2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Certificate No: 221j to BS 7846: 2009

Firetec Armoured LSZH


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 600/1000V Note: 1) Stranded conductors only. 2) In meeting the requirements of BS 7846: 2009, the Firetec Armoured LSZH cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994. Certificate No: 221k to BS 7846: 2009 Category F2 Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 221j/01

366

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES Firetec Armoured
Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 Uo/U 600/1000V Notes: 1) Stranded conductors only. 2) In meeting the requirements of BS 7846: 2009 Category F2, the Firetec Armoured cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994. Core Construction (see note 1) 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 221k/01

Certificate No: 221n to BS EN 60702-1: 2002 and BS 6387: 1994

AEI MI CABLE (LIGHT DUTY)


Nominal csa of conductor (mm) 1.0(1,2) 1.5(1,2) 2.5(1,2) 4.0(1,2) Uo/U 300/500V Notes: 1) Solid conductor only 2) The above cables are certified in Bare construction only. Certificate No: 221p to BS 60702-1: 2002, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2: 2009 120min, BS EN 50267-2-1: 1999 Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 BS EN 60702-1 Complies Complies Complies Complies BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z LPCB Ref. No. 221n/01

AEI MI CABLE (LIGHT DUTY)


Nominal csa of conductor (mm) 1.0(1,2) 1.5(1,2) 2.5
(1,2)

Core construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2

BS EN 60702-1 (see note 3) Complies Complies Complies Complies

BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z

BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120

BS 8434-2 120min 120min 120min 120min

BS 5839-1 Clause 26.2 Enhanced(4) Enhanced(4) Enhanced


(4)

BS EN 502672-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl

LPCB Ref. No. 221p/01

4.0(1,2)

Enhanced(4)

Uo/U 300/500V Notes: 1) 2) 3) 4) Solid conductor only. The above cables are certified in Served construction only. In meeting the requirements of BS EN 60702-1: 2002, the AEI MI CABLE (LIGHT DUTY) listed met the requirements of smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997. The AEI MI CABLE (LIGHT DUTY) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200:2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

12 Sep 2011

367

PART 1: SECTION 8
FIRE RESISTANT CABLES

Alpha Fire Services W.L.L.


P O Box 11741, Manama, Kingdom of Bahrain Tel: +973 1773 8100 / +973 3960 7378 Fax: +973 1773 6161 E-mail: farff@batelco.com.bh; admin@alphafirebahrain.com; admin1@afs-bahrain.com Website: www.alphafireservices.com
Certificate No: 568a-(cl-1) to BS 6387: 1994 and BS EN 50267-2-1: 1999

ALPHAFIRE FPC4
Nominal csa of conductors (mm2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl LPCB Ref. No. 568a/01

ATOM KABLO SANAYI VE TICARET A.S.


Ankara Karayolu 6. Km, Akkale Bedesi, Denizli 20155, Turkey Tel: +90 258 274 63 52 Fax: +90 258 274 64 31 E-mail: atom@atom.com.tr Website: www.atom.com.tr
Certificate No: 905a to BS 7846: 2009 Category F2

ATOM FIRERES ARMOURED


Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35 Uo/U 600/1000V Note 1: Note 2: Stranded conductors only. In meeting the requirements of BS 7846: 2009 Category F2, the ATOM FIRERES ARMOURED cableslisted met the requirements of smoke density of BS EN 61034 2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, tapes, filler, bedding and outer covering when tested in accordance with BS EN 50267 2 1: 1999. Core construction (see note 1) 2, 3, 4, 5, 7, 12 & 19 2, 3, 4, 5, 7, 12 & 19 2, 3, 4, 5, 7, 12 & 19 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 905a/01

Bangkok Cable Co Limited


93 Moo. 11 Suksawad Road, Naiklongbangplakod, Prasamutchedee, Samutprakarn, 10290, Thailand Tel: +662 2544550 Fax: +662 2543859

Certificate No: 576a to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2: 2000

368

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES 450/750V Low smoke halogen free fire resistant cable
Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 450/750V Notes: 1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 2) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. Certificate No: 576a to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2: 2000 Core Construction (see note 1) One (3) One (3) One (3) One (3) One (2,3) One (2,3) One (2,3) One (2,3) One (2,3) One (2,3) One (2,3) One (2,3) One One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 50268-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% LPCB Ref. No. 576a/01

600/1000V XLPE/Armoured/Low smoke halogen free fire resistant cable


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 450/750V Note: 1) The above named cable also met category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387 Core Construction (see note 1) One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One, 2, 3 & 4 One & 2 One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 50268-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% LPCB Ref. No. 576a/02

12 Sep 2011

369

PART 1: SECTION 8
FIRE RESISTANT CABLES

Cavicel SpA
Via Caduti del Lavoro, 18/A, 20096 Pioltello, Milan, Italy Tel: +39 02 9216 0521 Fax: +39 02 9216 0753 E-mail: cavicel@cavicel.com Website: www.cavicel.com
Certificate No: 217d to BS 6387:1994, BS EN 50267-2-1:1999

FIRECEL SR 112
Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 Uo/U 450/750 V Notes: 1. 2. 3. 4. 5. Stranded conductor only. Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. To satisfy the requirement of BS 6387, testing for C, W and Z categories was conducted using a 20mm steel conduit as the other metallic element. For large size cables, the category C testing was conducted using a 38mm steel conduit as the other metallic element. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. Core Construction (see note 1) One One One One One One One BS 6387 (see notes 2, 3, 4 & 5) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI LPCB Ref. No. 217d/01

Certificate No: 217f to BS 7629-1:2008, BS 6387:1994, BS EN 50200:2006, BS EN 50200:2006 Annex E, BS 5839-1:2002+A2:2008

FIRECEL SR 114H Fire Resistant Cable


Nominal csa of conductor (mm 2) Core Construction (excluding drain wire and earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 BS6387 BS EN 50200 BS EN 50200 Annex E BS 5839-1 Clause 26.2 LPCB Ref. No.

1.0(1) 1.5(2) 2.5(2) 4.0(3)

Complies(4) Complies(4) Complies(4) Complies(4)

C, W, Z C, W, Z C, W, Z C, W, Z

Class PH30 Class PH30 & PH60 Class PH30 & PH60 Class PH30 & PH60

30min(5) 30min(5) 30min(5) 30min(5)

Standard(6) Standard(6) Standard(6) Standard(6)

217f/01

Uo/U 300/500V Notes: 1. 2. 3. 4. Solid conductor only. Solid & Stranded conductors. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the FIRECEL SR 114H cables listed met the requirements of smoke density of BS EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. 5. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 6. The FIRECEL SR 114H cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 217g to BS 7629-1:2008, BS 6387:1994, BS EN 50200:2006, BS 8434-2:2003+A3:2009, BS 5839-1:2002+A2:2008

370

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES FIRECEL SR 114E Fire Resistant Cable
Nominal csa of conductor (mm2) 1.0(1) 1.5(2) 2.5(2) 4.0(3) Uo/U 300/500V Notes: 1. 2. 3. 4. Solid conductor only. Solid & Stranded conductors. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the FIRECEL SR 114E cables listed met the requirements of smoke density of BS EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. 5. The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. 6. The FIRECEL SR 114E cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 BS 6387 BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 Enhanced(6) Enhanced(6) Enhanced(6) Enhanced(6) LPCB Ref. No.

Complies(4) Complies(4) Complies(4) Complies(4)

C, W ,Z C, W, Z C, W, Z C, W, Z

Class PH120 Class PH120 Class PH120 Class PH120

120min(5) 120min(5) 120min(5) 120min(5)

217g/01

Certificate No: 217h to BS 6387: 1994 and BS EN 60702-1: 2002

FIRECEL MI 900 L
Nominal csa of conductor (mm 2) 1.0 1.5 2.5 4.0 Uo/U 300/500 V Note 1: The above range is certified in both Bare and Served constructions. Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z BS EN 60702-1 Complies Complies Complies Complies LPCB Ref. No. 217h/01

Certificate No: 217h to BS 6387: 1994 and BS EN 60702-1: 2002

FIRECEL MI 901 H
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo 750V Note 1: The above range is certified in both Bare and Served constructions. Core construction One One One One One One One One One One One One One One One One One BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 217h/02

12 Sep 2011

371

PART 1: SECTION 8
FIRE RESISTANT CABLES
Note 2: For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Certificate No: 217h to BS 6387: 1994 and BS EN 60702-1: 2002

FIRECEL MI 900 H
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 Uo/U 450/750V Core Construction 2, 3, 4, 7, 12 & 19 2, 3, 4, 7 &12 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 217h/03

Note 1: The above range is certified in both Bare and Served constructions. Note 2: For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer.

Context Plus Ltd


175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United Kingdom Tel: +44 (0)161 257 2541 Fax: +44 (0)161 225 8817 E-mail: xportsales@xportsales.com Website: www.xportsales.com
Certificate No: 682a-(cl-3) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2: 2008 Clause 26.2d

Context Plus
Nominal csa of conductor (mm 2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the Context Plus cables listed met the requirements of smoke density of BS EN 61034-2: 2005 fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 5) The Context Plus cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1 :2002+A2:2008. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 BS EN 50200 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Complies(3) Complies(3) Complies(3) Complies(3)

Class PH120 Class PH120 Class PH120 Class PH120

682a/01

372

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES

Dtwyler Cables
Unit of Dtwyler Switzerland Inc, Gotthardstrasse 31, CH-6460 Altdorf, Switzerland Tel: +41 41 875 1122 Fax: +41 41 875 1860 E-mail: info.ch@daetwyler-cables.com Website: www.daetwyler-cables.com
Certificate No: 172b to BS 7629-1: 2008, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E 30min and BS 5839-1: 2002+A2:2008 Clause 26.2d

Pyrofil Standard Fire Safety Cable


Nominal csa of conductor (mm2) 1.0(1) 1.5(2) 2.5(2) Uo/U Notes: 1) 2) 3) 4) 5) 300/500V Solid conductor only. Solid and stranded conductors. In meeting the requirements of BS 7629-1: 2008, the Pyrofil Standard Fire Safety Cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the outer covering, binder tape and insulation when tested in accordance with BS EN 50267-2-1: 1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. The Pyrofil Standard Fire Safety Cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core Construction (excluding drainwire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 Complies(3) Complies(3) Complies(3) BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH30 Class PH30 Class PH30 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) LPCB Ref. No. 172b/01

Certificate No: 172c to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120min and BS 5839-1: 2002+A2:2008 Clause 26.2e

Pyrofil Enhanced Fire Safety Cable


Nominal csa of conductor (mm) 1.5(1) 2.5(1) Core construction (excluding drain wire and earth) 2 2 BS 7629-1 BS 6387 BS EN 50200 BS 84342 BS 5839-1 Clause 26.2 Enhanced(4) Enhanced(4) LPCB Ref. No.

Complies(2) Complies(2)

C,W,Z C,W,Z

Class PH120 Class PH120

120min(3) 120min(3)

172c/01

Uo/U 300/500V Notes: 1) 2) 3) 4) Solid and stranded conductors. In meeting the requirements of BS 7629-1: 2008, the Pyrofil Enhanced Fire Safety Cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. The Pyrofil Enhanced Fire Safety Cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 200+A2:2008.

Certificate No: 172d to BS 6387: 1994, BS EN 61034-2: 2005, BS EN 50267-2-1: 1999, IEC 60754-1: 1994, BS EN 50267-2-3: 1999 and IEC 60754-2-am1: 1997

12 Sep 2011

373

PART 1: SECTION 8
FIRE RESISTANT CABLES Pyrofil Fire Safety BS 6387 CWZ
Nominal csa of conductor (mm) 1.5 2.5 Core Construction (see note 1) 2 2 BS 6387 C, W, Z C, W, Z BS EN 50267-2-1 (see note 2) <0.5% HCl <0.5% HCl BS EN 50267-2-3 (see note 3) Complies Complies BS EN 61034-2 >60% >60% LPCB Ref. No. 172d/01

Uo/U Note 1: Note 2: Note 3:

300/500V Solid conductors only. In achieving less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999, the Pyrofil Fire Safety BS 6387 CWZ cables listed also met the requirements of IEC 60754-1: 1994. In achieving a weighted average of pH greater than 4.3 and a weighted average of Conductivity less than 10S/mm on the constituent materials when tested in accordance with BS EN 50267-2-3: 1999, the Pyrofil Fire Safety BS 6387 CWZ cables listed also met the requirements of IEC 60754-2-am1: 1997.

Doncaster Cables
Millfields Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire DN5 0SJ, United Kingdom Tel: +44 (0)1302 821700 Fax: +44 (0)1302 821701 E-mail: sales@doncastercables.com Website: www.doncastercables.com
Certificate No: 338a to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E & BS 58391: 2002+A2:2008 Clause 26.2d

Firesure Cables
Nominal csa of conductor (mm2) 1.0(1) 1.5
(1)

Core construction (drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4

BS 7629-1 Complies(3) Complies


(3)

BS EN 50200 Class PH30 Class PH30 Class PH30 Class PH30

BS EN 50200 Annex E 30min(4) 30min


(4)

BS 5839-1 Clause 26.2 Standard(5) Standard


(5)

LPCB Ref. No. 338a/01

2.5(2) 4.0(2)

Complies(3) Complies(3)

30min(4) 30min(4)

Standard(5) Standard(5)

Uo/U 300/500V Note 1: Note 2 Note 3: Solid conductor only. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the Firesure Cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements of CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binding tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d of BS 5839-1: 2002+A2:2008. The Firesure Cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Note 4:

Note 5:

Certificate No: 338b to BS 7629-1: 2008, BS 6387: 1994, IEC 60331-21: 1999, IEC 60332-3-24: 2000+A1:2008, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120min and BS 5839-1: 2002+A2:2008 Clause 26.2e

374

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES FIRESURE PLUS
Nominal csa of conductor (mm 2) 1.0 (1) 1.5(1) 2.5(1) 4.0(2) Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 BS 6387 IEC 60331-21 IEC 60332-324 Complies Complies Complies Complies BS EN 50200 BS84342 BS 5839-1 LPCB Ref. No.

Complies(3) Complies(3) Complies(3) Complies(3)

C,W,Z C,W,Z C,W,Z C,W,Z

Complies(4) Complies(4) Complies(4) Complies(4)

Class PH120 Class PH120 Class PH120 Class PH120

120min(5) 120min(5) 120min(5) 120min(5)

Enhanced(6) Enhanced(6) Enhanced(6) Enhanced(6)

338b/01

Uo/U 300/500V Note 1: Note 2: Solid conductor only Stranded conductor only

Note 3: In meeting the requirements of BS 7629-1: 2008, the FIRESURE PLUS listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements of CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binding tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. Note 4 Note 5: These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C. The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e of BS 5839-1: 2002+A2:2008. The FIRESURE PLUS cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for a enhanced fire resistant cable as described in Clause 26.2e of BS 5839-1: 2002+A2:2008.

Note 6:

Draka UK Limited
Alfreton Road, Derby DE21 4AE, United Kingdom Tel: +44 (0)1332 345431 Fax: +44 (0)1332 331237 E-mail: firetuf@drakauk.com Website: www.drakauk.com
Certificate No: 361b to BS 6387: 1994 and BS EN 50267-2-1: 1999

FTP
Nominal csa of conductor (mm2) 1.5(1) 2.5(1) 4.0(1) 6.0(1) 10(1) 16(1) 25(1) 35(1) 50(1) 70(1) 95(1) 120(1) 150(1) 185(1) 240(1) 300(1) 400(1) Uo/U 600/1000V Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 (see notes 2 & 3) C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50267-2-1 (outer covering) <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI LPCB Ref. No.

361b/01

12 Sep 2011

375

PART 1: SECTION 8
FIRE RESISTANT CABLES
Note 1: Note 2: Note 3: Stranded conductor only. The FTP cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer.

Certificate No: 361c to BS 6387: 1994 and BS EN 50267-2-1: 1999

Firetuf FTPU 950 Fire Resistant Mifer OHLS cable


Nominal csa of conductor (mm2) 1.5 1.5 2.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 120/70 150/70 185/95 240/120 50/25 70/35 95/50 Uo/U 450/750V Notes: 1) The Firetuf FTPU 950 Fire Resistant Mifer OHLS cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 2) For cable with an outside diameter of in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Certificate No: 361d to BS7629-1: 2008, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2d, BS EN 50200: 2006 Class PH30 and BS EN 50200: 2006 Annex E Core Construction (excluding drain wire & earth) 2, 3, 4 & 5 7,10,12,16,20,21 & 30 2, 3, 4 & 5 7,10,12,16,20,21 & 30 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth 4+ Concentric Earth BS 6387 (see notes 1 & 2) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No.

361c/01

FT30
Nominal csa of conductor (mm2) 1.5 2.5 4.0 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 2008, the FT30 cables listed met the requirements of smoke density of BS EN 61034-2: 2005 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 BS 6387 BS EN 50200 BS EN 50200 Annex E 30min (2) 30min (2) 30min (2) BS 5839-1 Clause 26.2 Standard (3) Standard (3) Standard (3) LPCB Ref. No.

Complies (1) Complies (1) Complies (1)

C, W, Z C, W, Z C, W, Z

Class PH30 Class PH30 Class PH30

361d/01

376

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
3) The FT30 cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Certificate No: 361e to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2d, BS EN 50200: 2006 Class PH30 and BS EN 50200: 2006 Annex E

FT EMC
Nominal csa of conductor (mm2) 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 2008, the FT EMC cables listed met the requirements of smoke density of BS EN 610342: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999 . 2) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 3) The FT EMC cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Certificate No: 361f to BS 7629-1: 2008, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min Core Construction (excluding drain wire & earth) 2 2 BS 7629-1 BS EN 50200 BS EN 50200 Annex E 30min(2) 30min(2) BS 5839-1 Clause 26.2 Standard(3) Standard(3) LPCB Ref. No.

Complies(1) Complies(1)

Class PH30 Class PH30

361e/01

FT120
Nominal csa of conductor (mm2) 1.5 2.5 4.0 Core Construction (excluding drain wire and earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 BS 6387 C,W,Z C,W,Z C,W,Z BS EN 50200 Class PH120 Class PH120 Class PH120 BS 84342 120min (2) 120min (2) 120min
(2)

BS 5839-1 Clause 26.2 Enhanced


(3)

LPCB Ref. No. 361f/01

Complies
(1)

Complies
(1)

Enhanced
(3)

Complies
(1)

Enhanced
(3)

Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 2008, the FT120 cables listed met the requirements of smoke density of BS EN 61034-2: 2005 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. 3) The FT120 cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Certificate No: 361g to BS 8491: 2008, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and BS EN 60332-3-24: 2009

FTP120
Nominal csa of conductor (mm 2 ) 2.5(1,2) 4.0(1,2) 6.0(1,2) 10(1,2) 16(1,2) 25(1,2) 35(1,2) 50(1,2) Core Construction (excluding earth wire) 7 2, 3, 4 & 7 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 8491 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min BS EN 502672-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% BS EN 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 361g/01

12 Sep 2011

377

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm 2 ) 70(1,2) 95(1,2) 120(1,2) 150(1,2) 185(1,2) 240(1,2) 300(1,2) 400(1,2) Uo/U 600/1000V Note 1: Note 2: Stranded conductor only. All cables have the blue core designated as a Neutral conductor; only phase to earth voltage was applied to the 2 core cables. Core Construction (excluding earth wire) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 8491 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min BS EN 502672-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% BS EN 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No.

Certificate No: 361h to BS6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FT SIFER 950i
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. 6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. 7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. 8) FT SIFER 950i cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Certificate No: 361h to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999 Core construction (see note 1) One One One One One One One One One One One One One One One One One One One BS 6387 (see notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) IEC 60331-21 (see note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies BS EN 50267-2-1 (outer covering) <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI LPCB Ref. No. 361h/01

378

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES FT SIFER 950s
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 Uo/U 600/1000V Notes: 1) 2) 3) 4) 5) 6) 7) 8) Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. The FT SIFER 950s cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Core construction (see note 1) One One One One One One One One One One One One One One One One One One One One One BS 6387 (see notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C(7) C(7) C(7) IEC 60331-21 (see note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies BS EN 50267-2-1 (outer covering) <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI LPCB Ref. No. 361h/02

Dubai Cable Company (Private) Limited


Ducab-M2, Plot No. - J6 14-15-16,, Sector - M41, Industrial City of Abu Dhabi-1, Mussafah, Abu Dhabi, United Arab Emirates Tel: +9714 808 2500 Fax: +9714 808 2622 E-mail: ducab@ducab.com Website: www.ducab.com, Sales office: PO Box 11529, Dubai, United Arab Emirates
Certificate No: 949a to BS 7846: 2009

Ducab - FR
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 Uo/U 600/1000V Note 1: Stranded conductors only. Core construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 949a/01

12 Sep 2011

379

PART 1: SECTION 8
FIRE RESISTANT CABLES
Note 2: In meeting the requirements of BS 7846: 2009 Category F2, the Ducab - FR cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, tapes, filler, bedding and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

Dubai Cable Company (Private) Limited, Trading as Ducab


Old Abu Dhabi Road, Jebel Ali, Dubai, United Arab Emirates Tel: +9714 808 2500 Fax: +9714 808 2622 E-mail: ducab@ducab.com Website: www.ducab.com, Sales office: PO Box 11529, Dubai, UAE

Certificate No: 781a to BS 7846: 2000 (Incorporating Amendments Nos 1 and 2)

Ducab - FR
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In meeting the requirements of BS 7846: 2000 (incorporating Amendments Nos. 1 & 2) Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994. Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (Incorporating Amendments Nos. 1 and 2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 781a/01

Certificate No: 781b to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU)

Ducab - FR
Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 Uo/U 600/1000 V Notes: 1) Stranded conductors only. 2) In meeting the requirements of BS 7846: 2000 Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994. 3) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 781a covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2) Core Construction (see Note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see Notes 2 & 3) F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 781b/01

380

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES

Certificate No: 781c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50268-2: 2000 and IEC 60331-21: 1999

Ducab - FR SC
Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. 4) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 6) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Core Construction (see note 1) One One One One One BS 6387 (see notes 2 - 5) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 502672-1 <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl BS EN 50268-2 >60% >60% >60% >60% >60% IEC 6033121 (see note 6) Complies Complies Complies Complies Complies LPCB Ref. No. 781c/01

Dubai Cable Company (Private) Limited, Trading as Ducab


Ducab-M1, Plot No. - 2D12,3D2,4D2,5D2, Sector - M41, Industrial City of Abu Dhabi-1, Mussafah, Abu Dhabi, United Arab Emirates Tel: +9714 808 2500 Fax: +9714 808 2622 E-mail: ducab@ducab.com Website: www.ducab.com, Sales office: PO Box 11529, Dubai, UAE Sales office: PO Box 11529, Dubai, United Arab Emirates

Certificate No: 782a to BS 7846: 2000 (Incorporating Amendments Nos 1 and 2)

Ducab - FR
Nominal csa of conductor (mm2) 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 600/1000V Notes: 1) Stranded conductors only. 2) In meeting the requirements of BS 7846: 2000 Incorporating Amendments Nos. 1 & 2) Category F2, the Ducab - FR cables met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387:1994. Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (Incorporating Amendments Nos. 1 and 2) F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 782a/01

12 Sep 2011

381

PART 1: SECTION 8
FIRE RESISTANT CABLES

Certificate No: 782b to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU)

Ducab - FR
Nominal csa of conductor (mm2) 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 600/1000 V Notes: 1) Stranded conductors only. 2) In meeting the requirements of BS 7846: 2000 Category F2, the Ducab - FR cables listed met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994. 3) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 782a covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2) Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see notes 2 & 3) F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 782b/01

Certificate No: 782c to BS 6387: 1994, IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

Ducab - FR SC
Nominal csa of conductor mm 2 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Notes: 1) 2) 3) Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Core construction (See note 1) One One One One One One One One One One One One One One One One One One One BS 6387 (See notes 2 - 4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) BS EN 50267 -2-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 61034-2 IEC 60331-21 (See note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No.

>60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60%

782c/01

382

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
4) 5) 6) 7) 8) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V.

Certificate No: 782d to BS 7846: 2009 Category F2

Ducab - FR
Nominal csa of conductor (mm) 1.5 2.5 4.0 6.0 10 16 Core construction (see note 1) 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 782d/01

Uo/U 600/1000V Notes: 1) 2) Stranded conductors only. In meeting the requirements of BS 7846: 2009 Category F2, the Ducab-FR cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994.

Certificate No: 782f to BS 6387: 1994, IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

Ducab - FR SCS
Nominal csa of conductor (mm) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950oC and at a voltage rating of 600V. Core construction (See note 1) One One One One One One One One One One One One One One One One One One One BS 6387 (See notes 2 - 4) C, W, Z(5) C, W, Z(5) C, W, Z(6,7) C, W, Z(6,7) BS50267-2-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 782f/01

12 Sep 2011

383

PART 1: SECTION 8
FIRE RESISTANT CABLES

Eland Cables
120 Highgate Studios, 53-79 Highgate Road, London NW5 1TL, United Kingdom Tel: +44 (0)20 7241 8787 Fax: +44 (0)20 7241 8700 E-mail: sales@eland.co.uk Website: www.eland.co.uk
Certificate No: 568c-(cl-1) to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

FireForce
Nominal csa of conductor (mm) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 & 2) Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH30 Class PH30 Class PH30 Class PH30 BS 84341 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No. 568c/01

Notes: 1) Solid and Stranded conductors. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FireForce cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002. 5) The FireForce cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)


P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates Tel: +971 6 5340300 Fax: +971 6 5340090 E-mail: firex@emirates.net.ae Website: www.firexuae.com
Certificate No: 568a-(cl-3) to BS 6387: 1994 and BS EN 50267-2-1: 1999

FIREX
Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Certificate No: 568a-(cl-3) to BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01

FIREX-UK
Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01

384

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Certificate No: 711c-(cl-3) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

Tornado FE180 PH30


Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) Uo/U 300/500V Note: 1: Solid conductor only. Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH30 Class PH30 Class PH30 LPCB Ref. No. 711c/01

Fireguard Safety Equipment Co Ltd


2nd Floor, 145-147 St John Street, London EC1V 4PY, United Kingdom Tel: +44 (0)8450 751042 Fax: +44 (0)8450 751043 E-mail: info@fireguard-uk.com Website: www.fireguard-uk.com
Certificate No: 711c-(cl-2) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

Fireguard-UK FG FRC 180 PH30


Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) Uo/U 300/500V Note 1. Solid conductor only. Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH30 Class PH30 Class PH30 LPCB Ref. No. 711c/01

Global System Technology Plc


Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United Kingdom Tel: +44 (0)1283 225 478 Fax: +44 (0)1283 222 039 E-mail: info@gst.uk.com Website: www.gst.uk.com
Certificate No: 568a-(cl-2) to BS 6387: 1994 and BS EN 50267-2-1: 1999

GST
Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01

12 Sep 2011

385

PART 1: SECTION 8
FIRE RESISTANT CABLES
Uo/U 300/500 V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Certificate No: 682a-(cl-4) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN 50200: 2006 Annex E, BS 5839-1: 2002+A2: 2008 Clause 26.2d

GST
Nominal csa of conductor (mm) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No. 682a/01

Uo/U 300/500V Notes: 1) 2) 3) 4) 5) Solid conductor only Stranded conductor only In meeting the requirements of BS 7629-1:2008, the GST cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1:1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. The GST cables listed conform to BS 7629-1:2008, met Class PH120 when tested in accordance with BS EN 50200:2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002+A2:2008.

Grupo General Cable Sistemas, S.A.


CTRA. Rusinol, 63., 08560, Manlleu, Spain Tel: +34 93 852 02 00 Fax: +34 93 852 02 22 E-mail: info@generalcable.es Website: www.generalcable.es
Certificate No: 722a to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50268-2: 2000 and IEC 60331-21: 1999

SEGURFOC FR 950 07Z-R-M


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 Core Construction (see note 1) one (3,4) one (4,5,6) one (4,5,6) one (4,5,6) one (4,5,6) one (4,5,6) one (2,5,6) one (2,5,6) one (2,5,6) one (2,5,6) one (2,5,6) one (2,5,6) one (2,5,6) one (2,6) one (2,6) one (2,6) one (2,6) one (2,6) BS 6387 (insulation & Binder tape) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W C, W C, W C, W C, W C, W C, W C C C C C BS EN 50267-21 >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI >0.5%HCI BS EN 502682 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 6033121 (see note 7) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 722a/01

386

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Uo/U 450/750V Notes: 1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 2) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 3) To satisfy the requirement of BS 6387, testing for C & W categories was conducted using a 20mm stainless steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for Z category was conducted using a 20mm stainless steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for W category was conducted using a 38mm stainless steel conduit as the other metallic element. 6) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. 7) Testing to IEC 60331-21: 1999 was conducted at 450V.

Grupo General Cable Sistemas, S.A.


CTRA. DE RIBAS KM 13.250, Montcada I Reixac, 08110, Barcelona, Spain Tel: +34 93 227 95 00 Fax: +34 93 227 95 22 E-mail: info@generalcable.es Website: www.generalcable.es
Certificate No: 730a to BS 7846: 2000 (Incorporating Amendment Nos 1 and 2)

SEGURFOC FRA 950


Nominal csa of conductor (mm2) 1.5(1) 2.5(1) 4.0(1) 6.0(1) 10(1) 16(1) 25(1) 35(1) 50(1) 70(1) 95(1) 120(1) 150(1) 185(1) Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In meeting the requirements of BS 7846 category F2, the SEGURFOC FRA 950 cable met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see note 2) F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 LPCB Ref. No. 730a/01

Certificate No: 730a to BS 7846: 2000 (Incorporating Amendment Nos 1 and 2)

SEGURFOC FRA-1 950


Nominal csa of conductor (mm2) 240(1) 300(1) 400(1) Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In meeting the requirements of BS 7846 category F2, the SEGURFOC FRA-1 950 cable met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387. Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 (see note 2) F2 F2 F2 LPCB Ref. No. 730a/02

12 Sep 2011

387

PART 1: SECTION 8
FIRE RESISTANT CABLES

Huzhou Jiusheng Electric Co Ltd


1000 Xifeng Road, Huzhou Economy & Technologhy Area, Huzhou, Zhejiang, China Tel: +86 572 222 8188 Fax: +86 572 222 8177 E-mail: zjh@hz-tec Website: www.teccable.com
Certificate No: 948a to BS EN 60702-1: 2002 and BS 6387: 1994

TEC MI BARE CABLE (LIGHT DUTY)


Nominal csa of conductor (mm) 1.0(1,2) 1.5(1,2) 2.5(1,2) 4.0(1,2) Uo/U 300/500V Notes: 1) 2) Solid conductor only. The above cables are certified in Bare construction only. Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 BS EN 60702-1 Complies Complies Complies Complies BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z LPCB Ref. No. 948a/01

Certificate No: 948b to BS 60702-1: 2002, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120, BS 8343-2: 2003+A2:2009 120min and BS EN 50267-2-1: 1999

TEC MI SERVED CABLE (LIGHT DUTY)


Nominal csa of conductor (mm) 1.0(1,2) 1.5
(1,2)

Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2

BS EN 60702-1 (see note 3) Complies Complies Complies Complies

BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z

BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120

BS 8434-2 120min 120min 120min 120min

BS 5839-1 Clause 26.2 Enhanced(4) Enhanced


(4)

BS EN 502672-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl

LPCB Ref. No. 948b/01

2.5(1,2) 4.0
(1,2)

Enhanced(4) Enhanced
(4)

Uo/U 300/500V Notes: 1) 2) 3) 4) Solid conductor only. The above cables are certified in Served construction only. In meeting the requirements of BS EN 60702-1: 2002, the TEC MI SERVED CABLE (LIGHT DUTY) listed met the requirements of smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997. The TEC MI SERVED CABLE (LIGHT DUTY) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Irish Driver-Harris Company Limited


Millbanks, New Ross, Co. Wexford, Ireland Tel: +353 51 421 405 Fax: +353 51 422 983 E-mail: sales@idh.ie Website: www.idh.ie
Certificate No: 408a to BS 7629-1:1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30, BS8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

388

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES Kilflam 2000
Nominal csa of conductor (mm2) 1.0(1) 1.5(2,3) 2.5(4) 4.0(4) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Solid conductor at 3 & 4 cores only. 3) Stranded conductor at 2 core only. 4) Stranded conductor only. 5) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), the Kilflam 2000 cables met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCI on the (outer covering, insulation and binder tape) when tested in accordance with BS EN 50267-2-1: 1999. 6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002. 7) The Kilflam 2000 cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200:2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002. Certificate No: 408b to BS 6387: 1994 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos.1 & 2) Complies(5) Complies(5) Complies(5) Complies(5) BS EN 50200 BS 8434-1 BS 5839-1 Clause 26.2 Standard(7) Standard(7) Standard(7) Standard(7) LPCB Ref. No.

Class PH30 Class PH30 Class PH30 Class PH30

30min(6) 30min(6) 30min(6) 30min(6)

408a/01

Kilflam 1000
Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10.0 16.0 Uo/U 450/750V Notes: 1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable only having one core. 2) To satisfy the requirements of BS 6387, testing for C, W and Z categories was conducted using 20mm steel conduit as the other metallic element. Certificate No: 408d to BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z LPCB Ref. No. 408b/01

Kilflam 1200
Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10.0 Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 3) The Kilflam 1200 cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 20mm steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element. Core Construction (see note 1) One(4,6) One(4,6) One(4,6) One(5,6) One(5,6) BS 6387 (see notes 2, 3 & 7) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl LPCB Ref. No. 408d/01

12 Sep 2011

389

PART 1: SECTION 8
FIRE RESISTANT CABLES
6) To satisfy the requirement of BS 6387, testing for W and Z categories was conducted using a 20mm steel conduit as the other metallic element. 7) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. Certificate No: 408e to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

Kilflam 2000
Nominal csa of conductor (mm) 1.0(1) 1.5(2,3) 2.5(4) 4.0(4) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Solid conductor at 3 & 4 cores only. 3) Stranded conductor at 2 core only. 4) Stranded conductor only 5) In meeting the requirements of BS 7629-1: 1997, the Kilflam 2000 cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. 6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 7) The Kilflam 2000 cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. 8) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 408a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (see note 8) Complies(5) Complies(5) Complies(5) Complies(5) BS EN 50200 BS 8434-1 BS 5839-1 Clause 26.2 Standard(7) Standard(7) Standard(7) Standard(7) LPCB Ref. No.

Class PH30 Class PH30 Class PH30 Class PH30

30min(6) 30min(6) 30min(6) 30min(6)

408e/01

Certificate No: 408b-(cl-1) to BS 6387: 1994

Fumeguard FR
Nominal csa of conductor (mm) 1.5 2.5 4.0 6.0 10.0 16.0 Uo/U 450/750V Notes: 1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 2) To satisfy the requirement of BS 6387, testing for C, W, and Z categories was conducted using 20mm steel conduit as the other metallic element. Certificate No: 408f to BS 7629-1: 2008, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E 30min and BS 5839-1: 2002+A2:2008 Clause 26.2d Core construction One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z LPCB Ref. No. 408b/01

Kilflam Standard 2000


Nominal csa of conductor (mm) 1.0(1) Core construction (excluding earth wire) 2, 3 & 4 BS 7629-1 Complies(3) BS EN 50200 Class PH30 BS EN 50200 Annex E 30min(4) BS 5839-1 Clause 26.2 Standard(5) LPCB Ref. No. 408f/01

390

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm) 1.5(1) 2.5(2) 4.0(2) Uo/U 300/500V Notes: 1) 2) 3) 4) 5) Solid conductor only. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the Kilflam Standard 2000 cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002+A2:2008. The Kilflam Standard 2000 cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core construction (excluding earth wire) 2, 3 & 4 2, 3 & 4 2 BS 7629-1 Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH30 Class PH30 Class PH30 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Certificate No: 408g to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Kilflam Standard 2000


Nominal csa of conductor (mm) 1.0(1) 1.5(1) 2.5(2) 4.0(2) Uo/U 300/500V Notes: 1) 2) 3) 4) 5) Solid conductor only. Stranded conductor only. In meeting the requirements of BS 7629-1: 1997, the Kilflam Standard 2000 cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002+A2:2008. The Kilflam Standard 2000 cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core construction (excluding earth wire) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 (see note 6) Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH30 Class PH30 Class PH30 Class PH30 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No. 408g/01

Certificate No: 408h to BS 7846: 2009 Category F2

Kilflam 4000 SWA


Nominal csa of conductor (mm) 1.5 2.5 4.0 6.0 10 16 Uo/U 600/1000V Note 1: Note 2: Stranded conductors only. In meeting the requirements of BS 7846: 2009 Category F2, the Kilflam 4000 SWA cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994. Core construction (see note 1) 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 408h/01

12 Sep 2011

391

PART 1: SECTION 8
FIRE RESISTANT CABLES

Certificate No: 408j to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009

Kilflam 3000
Nominal csa of conductor (mm) 1.0(1) 1.5(1) 2.5(2) 4.0(3) Uo/U 300/500V Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Solid conductor only. Solid & Stranded conductors. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the Kilflam 3000 cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. The Kilflam 3000 cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 Complies(4) Complies(4) Complies(4) Complies(4) BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS 8434-2 120min(5) 120min(5) 120min(5) 120min(5) BS 5839-1 Clause 26.2 Enhanced(6) Enhanced(6) Enhanced(6) Enhanced(6) LPCB Ref. No. 408j/01

Certificate No: 408k to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

Kilflam 1000 a
Nominal csa of conductor (mm) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 Uo/U 600/1000V Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Note 9: Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. The Kilflam 1000 a cable also met IEC 60331-21: 1999 when installed in steel conduit. Core construction (See note 1) One One One One One One One One One One One One One BS 6387 (See notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C(7) C(7) C(7) C(7) BS EN 50267-2-1 (Outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl IEC 60331-21 (See notes 8 & 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 408k/01

Certificate No: 408m to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

392

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES Fumeguard FR a
Nominal csa of conductor (mm) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 Uo/U 600/1000V Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Note 9: Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. The Fumeguard FR a cable also met IEC 60331-21: 1999 when installed in steel conduit. Core construction (See note 1) One One One One One One One One One One One One One BS 6387 (See notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C(7) C(7) C(7) C(7) BS EN 50267-2-1 (Outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl IEC 60331-21 (See notes 8 & 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 408m/01

Jaylow Supplies Ltd


Jaylow House, Leyton Link Estate, Argall Avenue, Leyton, London E10 7FD, United Kingdom Tel: +44 (0)870 444 6890 Fax: +44 (0)870 444 6891 Website: www.jaylowcables.com
Certificate No: 682a-(cl-1) to BS 7929-1: 2008, BS EN 50200: 2006 Class PH120, BS EN50200: 2006 Annex E and BS 58391:2002+A2: 2008 Clause 26.2d

Jayflame
Nominal csa of conductor (mm2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the Jayflame cables listed met the requirements of smoke density of BS EN 610342: 2005 fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 5) The Jayflame cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 BS EN 50200 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Complies(3) Complies(3) Complies(3) Complies(3)

Class PH120 Class PH120 Class PH120 Class PH120

682a/01

12 Sep 2011

393

PART 1: SECTION 8
FIRE RESISTANT CABLES

Keystone Electric Wire & Cable Company Ltd


#110 DD 83, Kwan Ti North Village, Fanling, New Territories, Hong Kong Tel: +852 2691 7183 Fax: +852 2695 9738 E-mail: sales@keystonecable.com Website: www.keystonecable.com Manufacturing at: Dongguan Keystone Electric Wire & Cable Co Ltd, Ye Sha Management District,, Shatin, Dongguan City, Guangdong, China Tel: +86 769 8886 1814 Fax: +86 769 8886 1696 E-mail: jessey@keystonecable.com

Sales Office: Tel: +852 2691 7183 Fax: +852 2695 9738 E-mail: sales@keystonecable.com Website: www.keystonecable.com

Certificate No: 663b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and IEC 60331-21: 1999

KEYSTONE FR 7211 Cable


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 Uo/U 450/750V Notes: 1) Stranded conductor only. 2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 4) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for Z category was conducted using a 20mm steel conduit as the other metallic element. 6) To satisfy the requirement of BS 6387, testing for C & W category was conducted using a 38mm steel conduit as the other metallic element. 7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element. Core Construction (see note 1) One One One One One One One One One One One One One One One One BS 6387 (see note 23) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(5,6) C,W,Z(5,6) C,W,Z(5,6) C(7) C(7) C(7) C(7) C(7) C(7) C(7) C(7) BS EN 50267-21 <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI BS EN 610342 >60% >60% >60% >60% >60% >60% >60% >60% IEC 6033121 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 663b/01

394

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES Manufacturing at: Dongguan Keystone Electric Wire & Cable Co Ltd, Ye Sha Management District,, Shatin, Dongguan City, Guangdong, China Tel: +86 769 8886 1814 Fax: +86 769 8886 1696 E-mail: jessey@keystonecable.com

Sales Office: Tel: +852 2691 7183 Fax: +852 2695 9738 E-mail: sales@keystonecable.com Website: www.keystonecable.com

Certificate No: 663c to BS 7846: 2009

KEYSTONE Fire Resistance Armoured Cable


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 663c/01

Uo/U 600/1000V Note: 1) Stranded conductors only. 2) In meeting the requirements of BS 7846: 2009, the KEYSTONE Fire Resistance Armoured Cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994.

KME Italy SpA


Via Della Repubblica 257, 55051 Fornaci Di Barga, Lucca, Italy Tel: +39 0583 701.1 Fax: +39 0583 701623 E-mail: massimo.banfi@kme.com Website: www.kme-italy.com
Certificate No: 427a to BS 6387: 1994 and BS EN 60702-1: 2002

MICO - KME Light duty Mineral Insulated Cable


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 Uo/U 300/500V Note: 1. The above range is certified in both Bare and Served constructions. Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies LPCB Ref. No. 427a/01

12 Sep 2011

395

PART 1: SECTION 8
FIRE RESISTANT CABLES
Certificate No: 427a to BS 6387: 1994 and BS EN 60702-1: 2002

MICO - KME Single core heavy duty mineral insulated cables


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo 750V Notes: 1) The above range is certified in both Bare and Served constructions. 2) For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Certificate No: 427a to BS 6387: 1994 and BS EN 60702-1: 2002 Core Construction One One One One One One One One One One One One One One One One One BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 427a/02

MICO - KME Multi-core heavy duty mineral insulated cables


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 Uo/U 450/750V Notes: 1) The above range is certified in both Bare and Served constructions. 2) For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the manufacturer. Core Construction 2, 3, 4, 7, 12 & 19 2, 3, 4, 7 & 12 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 427a/03

LEONI Studer AG
Herrenmattstr. 20, CH 4658 Dniken, , Switzerland Tel: +41 62 288 83 15 Fax: +41 62 288 83 83 E-mail: wolfgang.miess@leoni-studer.ch Website: www.leoni-infrastructure.com
Certificate No: 896a to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 90 Cable Single Core Sl


Nominal csa of conductor (mm 2 ) 1.5 2.5 Core Construction (See note 1) one one BS 6387 (See notes 2-4) C,W,Z (5) C,W,Z (5) BS EN 50267-2-1 <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% IEC 60331-21 (See note 9) Complies Complies IEC 60332-324 Complies Complies LPCB Ref. No. 896a/01

396

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm 2 ) 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Notes: 1) 2) 3) 4) 5) 6) 7) 8) 9) Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. Only Clause 10 of BS 6387 was conducted. The BETAflam FR-MI 90 Cable Single Core SI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Core Construction (See note 1) one one one one one one one one one one one one one one one one one BS 6387 (See notes 2-4) C,W,Z (5) C,W,Z (5) C,W,Z (5) C,W,Z (5) C,W,Z (6,7) C,W,Z (6,7) C,W,Z (6,7) C,W,Z (6,7) C,W,Z (6,7) C(7) C(7) C(7) C(7) C(7) C(7) Complies(8) Complies(8) BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See note 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies IEC 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No.

Certificate No: 896a to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 90 Cable Single Core DI


Nominal csa of conductor (mm 2 ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Notes: Core Construction (See note 1) one one one one one one one one one one one one one one one one one one one BS 6387 (See notes 2-4) C,W,Z
(5)

BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI

BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60%

IEC 60331-21 (See note 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies

IEC 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies

LPCB Ref. No. 896a/02

C,W,Z C,W,Z (5) C,W,Z (5) C,W,Z (5) C,W,Z (5) C,W,Z (6,7) C,W,Z (6,7) C,W,Z (6,7) C(7) C(7) C(7) C(7) C(7) C(7) C(7) Complies(8) Complies(8) Complies(8)

(5)

12 Sep 2011

397

PART 1: SECTION 8
FIRE RESISTANT CABLES
1) 2) 3) 4) 5) 6) 7) 8) 9) Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. Only Clause 10 of BS 6387 was conducted. The BETAflam FR-MI 90 Cable Single Core DI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V.

Certificate No: 896b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Single Core SI


Nominal csa of conductor (mm 2 ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Notes: 1) 2) 3) 4) 5) 6) 7) 8) 9) Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. Only Clause 10 of BS 6387 was conducted. The BETAflam FR-MI 110 Cable Single Core SI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Core Construction (See Note 1) one one one one one one one one one one one one one one one one one one one BS 6387 (See Notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C(7) C(7) C(7) C(7) C(7) C(7) Complies(8) Complies(8) BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See note 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies IEC 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 896b/01

Certificate No: 896b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Single Core DI


Nominal csa of conductor (mm 2 ) 1.5 2.5 4.0 Core Construction (See note 1) one one one BS 6387 (See notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% IEC 60331-21 (See note 9) Complies Complies Complies IEC 60332-324 Complies Complies Complies LPCB Ref. No. 896b/02

398

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm 2 ) 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 600/1000V Notes: 1) 2) 3) 4) 5) 6) 7) 8) 9) Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. Only Clause 10 of BS 6387 was conducted. The BETAflam FR-MI 110 Cable Single Core DI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Core Construction (See note 1) one one one one one one one one one one one one one one one one BS 6387 (See notes 2-4) C,W,Z(5) C,W,Z(5) C,W,Z(5) C,W,Z(6,7) C,W,Z(6,7) C,W,Z(6,7) C(7) C(7) C(7) C(7) C(7) C(7) C(7) Complies(8) Complies(8) Complies(8) BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See note 9) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies IEC 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No.

Certificate No: 896c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Multicore


Nominal csa of conductor (mm 2 ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U Notes: 1) 2) 600/1000V Stranded conductor only. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Core Construction (See note 1) 2, 3, 4, 5, 6, 7, 8, 10, 14, 19, 21, 24, 27, 33, 37 & 41 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 21 & 24 2, 3, 4, 5, 6 & 7 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 2, 3, 4 & 5 3&4 3&4 3&4 3&4 3&4 3&4 BS 6387 (See note 2) C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See Note 3) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies IEC 60332-324 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 896c/01

12 Sep 2011

399

PART 1: SECTION 8
FIRE RESISTANT CABLES
3) The BETAflam FR-MI 110 Cable Multicore cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600/1000V.

Certificate No: 896c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Multicore STA


Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35(3) 50 70 95 120 150 185 240 300 400 Uo/U Notes: 1) 2) 3) 4) 600/1000V Stranded conductor only. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. BS EN 61034-2: 2005 approval applies to the 35mm2 cable at 3 & 4 cores only. The BETAflam FR-MI 110 Cable Multicore STA cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600/1000V. Core Construction (See note 1) 2, 3, 4, 5, 7, 10, 19, 21 & 41 2, 3, 4, 5, 7, 10 & 21 2, 3, 4, 5 & 7 2, 3, 4 & 5 2, 3, 4 & 5 3, 4 & 5 3, 4 & 5 3, 4 & 5 3&4 3&4 3&4 3&4 3&4 3&4 3&4 3&4 3&4 BS 6387 (See note 2) C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See note 3) Complies Complies Complies Comlies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies IEC 603323-24 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 896c/02

Certificate No: 896c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Multicore SWA


Nominal csa of conductor (mm 2) 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U Notes 1) 2) 600/1000V Stranded conductor only. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Core Construction (See note 1) 3, 4 & 5 3, 4 & 5 3, 4 & 5 3, 4 & 5 3, 4 & 5 3, 4 & 5 3, 4 & 5 3&4 3&4 3&4 3&4 3&4 3&4 3&4 3&4 3&4 BS 6387 (See note 2) C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% IEC 60331-21 (See note 3) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies IEC 603323-24 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 896c/03

400

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
3) The BETAflam FR-MI 110 Cable Multicore SWA cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600/1000V.

Certificate No: 896d to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Comms S/UTP


Nominal csa of conductor (mm 2) 0.75(1) 1.0(1) 1.5(1, 2) 2.5(1) Uo/U Notes: 1) 2) 3) 300/500V Stranded conductor only. BS EN 61034-2: 2005 approval applies to the 1.5mm2 cable at 1, 2 & 3 pairs only. The BETAflam FR-MI 110 Cable Comms S/UTP cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 300/500V. Core Construction (excluding drain wire) 1, 2, 3, 5, 7 & 10 pairs 1, 2, 3, 5, 7 & 10 pairs 1, 2, 3, 5, 7 & 10 pairs 1, 2, 3, 5, 7 & 10 pairs BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% IEC 60331-21 (See note 3) Complies Complies Complies Complies IEC 603323-24 Complies Complies Complies Complies LPCB Ref. No. 896d/01

NAJD ELECTRICALS & SAFETY EQUIPMENT TRADING


Damascus Street, Al Qusais, Dubia, United Arab Emirates Tel: +971 4 267 5414 Fax: +971 4 267 5443 E-mail: najdelec@emirates.net.ae
Certificate No: 568d-(cl-1) to IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

JST Fire Cable IEC 60331


Nominal csa of conductor (mm) 1.0(1) 1.5(1) 2.5(1) Uo/U 300/500V Note: 1. Solid and Stranded conductors. Core construction drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 IEC 60331-21 Complies Complies Complies BS EN 50267-2-1 <0.5% HCl <0.5% HCl <0.5% HCl BS EN 61034-2 >60% >60% >60% LPCB Ref. No. 568d/01

Certificate No: 568a-(cl-4) to BS 6387: 1994 and BS EN 50267-2-1: 1999

JST Fire Cable


Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500V Notes: 1. Solid and Stranded conductors. 2. Stranded conductor only. Core construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No. 568a/01

12 Sep 2011

401

PART 1: SECTION 8
FIRE RESISTANT CABLES

Nexans Turkiye Endustri ve Ticaret A.S.


Izmir Karayolu Uzeri 6.km, Denizli, Turkey Tel: 0090 212 266 0160 Fax: 0090 212 266 0170 E-mail: Info.turkey@nexans.com Website: www.nexans.com.tr
Certificate No: 946a to BS 7846: 2009 Category F2

NX 400 ALSECURE PLUS


Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 600/1000V Notes: 1) 2) Stranded conductors only. In meeting the requirements of BS 7846: 2009 Category F2, the NX 400 ALSECURE PLUS cables listed met the requirements for fire resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994. Core Construction (see note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 946a/01

Certificate No: 946b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and IEC 60331-21: 1999

NX 100 ALSECURE PLUS


Nominal csa of conductor (mm 2 ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 Uo/U 450/750V Note 1: Note 2: Note 3: Note 4: Stranded conductor only. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. Where a single cable is fitted in a conduit, only phase to earth voltage was applied. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. Core construction (See note1) One One One One One One One One One One One One One One One One BS 6387 (See notes 23) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(5,6) C,W,Z(5,6) C,W,Z(5,6) C,W,Z(5,6) C,W,Z(5,6) C,W,Z(5,6) C(6) C(6) C(6) C(6) C(6) BS EN 50267-21 <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI <0.5% HCI BS EN 610342 >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% >60% IEC 6033121 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 946b/01

402

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Note 5: Note 6: To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element.

Norden Communication UK Ltd


2nd Floor, 145-157 St John Street, London EC1V 4PY, United Kingdom Tel: +44 (0) 207 788 7663 Fax: +44 (0) 203 292 1987 E-mail: sales@nordencommunication.com Website: www.nordencommunication.com
Certificate No: 711c-(cl-1) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

FireNor PH30
Nominal csa of conductors (mm) 1.0(1) 1.5(1) 2.5(1) Uo/U 300/500V Note: 1. Solid conductor only. Core construction drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50200 Class PH30 Class PH30 Class PH30 LPCB Ref. No. 711c/01

Prysmian Cables & Systems Limited


Energy Cables Unit, Wrexham Industrial Estate, Wrexham LL13 9PH, United Kingdom Tel: +44 (0)1978 662345 Fax: +44 (0)1978 662292 E-mail: cables.marketing.uk@prysmian.com Website: www.prysmian.co.uk
Certificate No: 517a to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FP300 Single Core LSZH Cable


Nominal csa of conductor (mm2) 50 70 95 120 185 240 300 400 630 800 1000 Uo/U 450/750V Notes: 1) These cables also met category C when tested for voltage rating 600/1000V which is not recognised by BS 6387. 2) Clause 8 (bending) and 9.1 & 9.2 (impact) can not be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for category C was conducted using 38mm steel conduit as the other metallic element. 4) Where single cable is fitted in conduit, only phase to earth voltage was applied. 5) Only clause 10 of BS 6387 was conducted. 6) These cables met the requirements of IEC 60331 when tested at a temperature of 950C (which is not recognised by IEC 60331) and at a voltage rating of 600V. Certificate No: 517b to BS 6387:1994 Core Construction One One One One One One One One One One One BS 6387 (see notes 1 to 4) C C C C C C Complies(5) Complies(5) Complies(5) Complies(5) Complies(5) BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI IEC 60331-21 (see note 6) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 517a/01

12 Sep 2011

403

PART 1: SECTION 8
FIRE RESISTANT CABLES FP400 Fire resistant cable
Nominal csa of conductor (mm2) 50 70 95 120 185 240 300 400 Uo/U 450/750V Note: 1) The FP400 cable also met categories C, W, and Z when tested for voltage rating of 600/1000V which is not recognised by BS 6387. Certificate No: 517c to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005 Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z LPCB Ref. No. 517b/01

FP600S
Nominal csa of conductor (mm 2) 70(1) 95(1) 120(1) 150
(1)

Core construction (See note 1) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4

BS 7346-6 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min

BS 8491 (fire survival time see note 2) 120min 120min 120min 120min 120min 120min 120min 120min

BS EN 50267-2-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl

BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60%

LPCB Ref. No. 517c/01

185(1) 240
(1)

300(1) 400(1)

Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the FP600S cables listed also achieved a 120min fire survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B.

Prysmian Cables & Systems Ltd


Energy Cables, Chickenhall Lane, Bishopstoke, Eastleigh, Hants SO50 6YU, United Kingdom Tel: +44 (0)8457 678345 Fax: +44 (0)2380 295465 E-mail: cables.marketing.uk@prysmian.com Website: www.prysmian.co.uk
Certificate No: 077a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

FP200 Gold LSOH


Nominal csa of conductor (mm2) 1.0 1.5 2.5 Core Construction (excluding drain wire & earth) 7 7, 12 & 19 7 & 12 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies(1) Complies(1) Complies(1) LPCB Ref. No. 077a/02

404

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Uo/U 300/500V Note: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Gold LSOH cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. Certificate No: 077a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

FP200 Flex
Nominal csa of conductor (mm2) 1.0 1.5 2.5 Uo/U 300/500V Note: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Flex cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. Certificate No: 077b to BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies(1) Complies(1) Complies(1) LPCB Ref. No. 077a/03

FP 300 fire resistant cable LSOH outer covering


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10 16 Uo/U 450/750V Note: 1) The FP300 LSOH cable also met Category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. Certificate No: 077b to BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No. 077b/01

FP 400 fire resistant cable LSOH outer covering


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Core Construction 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 BS 6387 (see note 1) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No. 077b/02

12 Sep 2011

405

PART 1: SECTION 8
FIRE RESISTANT CABLES
Uo/U 450/750V Notes: 1) The FP400 cable also met category C, W, Z when tested for voltage rating 600/1000 V which is not recognisedby BS 6387. 2) The FP400 cable approved with insulation type XLPE (GP8). 3) The FP400 cable approved with insulation type EPR (GP6). Certificate No: 077b to BS 6387: 1994 and BS EN 50267-2-1: 1999

FP 200 Gold LSOH


Nominal csa of conductor (mm2) 2.5 Uo/U 300/500V Certificate No: 077c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999 Core Construction (excluding drain wire & earth) 19 BS 6387 C&W BS EN 50267-2-1 (binder tape & outer covering) <0.5% HCl LPCB Ref. No. 077b/03

FP 100 Fire resistant single core cable for installation in conduit


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 450/750V Notes: 1) Testing was conducted using 20mm steel conduit. 2) To satisfy the requirement of BS 6387 the conduit was considered as the other metallic element. 3) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 4) Only a single cable is fitted in conduit, hence only phase to earth voltage was applied. 5) Testing to IEC 60331 was conducted at voltage rating of 600/1000V and at 950C. Core Construction One One One One One One One One One One One One One One One One One One One One BS 6387 (see notes 1 - 4) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C C BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl IEC 60331-21 (see Note 5) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 077c/01

Certificate No: 077d to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2:2000

FP150 LS0H
Nominal csa of conductor (mm2) 1.0 1.5 2.5 Uo/U 300/500V Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl BS EN 50268-2 >60% >60% >60% LPCB Ref. No. 077d/01

406

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Certificate No: 077e to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21:1999

FP 300 single core cable


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 450/750V Notes: 1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) of the BS 6387 standard cannot be conducted due to the cable having only one core. 2) The single core cable also met category C, W, Z when tested for voltage rating 600/1000 V which is not recognised by BS 6387. 3) To satisfy the requirement of BS 6387, testing for C, W and Z categories was conducted using a 20mm steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element. 5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 6) Only clause 10 of BS 6387 was conducted. 7) Testing to IEC 60331 was conducted at voltage rating of 600/1000V and at 950oC. Certificate No: 077e to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999 Core Construction One One One One One One One One One One One One One One One One One One One One BS 6387 (see notes 1,2, & 5) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C(4) C(4) C(4) C(4) C(4) C(4) C(4) Complies(6) Complies(6) Complies(6) Complies(6) BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl IEC 60331-21 (see Note 7) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 077e/01

FP 300MI single core cable


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Uo/U 450/750V Notes: 1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) of the BS 6387 standard cannot be conducted due to the cable having only one core. Core Construction One One One One One One One One One One One One One One One One One One One One BS 6387 (see notes 1, 2 & 5) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C(4) C(4) C(4) C(4) C(4) C(4) C(4) Complies(6) Complies(6) Complies(6) Complies(6) BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl IEC 60331-21 (see note 7) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 077e/02

12 Sep 2011

407

PART 1: SECTION 8
FIRE RESISTANT CABLES
2) The single core cable also met category C, W, Z when tested for voltage rating 600/1000 V which is not recognised by BS 6387. 3) To satisfy the requirement of BS 6387, testing for C,W, and Z categories was conducted using a 20mm steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic element. 5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 6) Only clause 10 of BS 6387 was conducted. 7) Testing to IEC 331 was conducted at voltage rating of 600/1000V and at 950C which is not recognised by the standard. Certificate No: 077f to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30 & PH60 and BS 5839-1: 2002 Clause 26.2d

FP200 Gold LSOH


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendment Nos. 1 & 2) Complies(1) Complies(1) Complies(1) Complies(1) BS EN 50200 BS 5839-1 Clause 26.2 Standard(2) Standard(2) Standard(2) Standard(2) LPCB Ref. No. 077f/01

Class PH30 Class PH30 & PH60 Class PH30 & PH60 Class PH30 & PH60

Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Gold LSOH cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. 2) The FP200 Gold LSOH cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water tests described in Clause 26.2 d) of BS 5839-1: 2002 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 077g to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min & BS 5839-1: 2002 Clause 26.2e

FP Plus
Nominal csa of conductor (mm2) 1.0 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendmennt Nos. 1 & 2), the FP Plus cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 3) The FP Plus cables listed conform to BS 7629-1: 1997, meet Class PH120 when tested in accordance with EN 50200: 2000 and meet a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence meet the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 077h to BS 7629-1: 1997 (Incorporating Amendment No.1), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: Clause 26.2e Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendment Nos.1 & 2) Complies(1) Complies(1) Complies(1) BS EN 50200 Class PH120 Class PH120 Class PH120 BS 8434-2 120min 120min 120min BS 5839-1 Clause 26.2 Enhanced(3) Enhanced(3) Enhanced(3) LPCB Ref. No. 077g/01

408

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES FP Plus Flex
Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 Core Construction (excluding drain wire & earth) 2,3 & 4 2,3 & 4 2,3 & 4 2,3 & 4 BS 7629-1 (Incorporating Amendment No.1) Complies (1) Complies(1) Complies(1) Complies(1) BS EN 50200 BS 84342 BS 5839-1 Clause 26.2 Enhanced(3) Enhanced(3) Enhanced(3) Enhanced(3) LPCB Ref. No.

Class PH120 Class PH120 Class PH120 Class PH120

120min(2) 120min(2) 120min(2) 120min(2)

077h/01

Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the FP Plus Flex cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. 2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 3) The FP Plus Flex cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 077j to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).

FP200 Gold LSOH


Nominal csa of conductor (mm2) 1.0 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997, the FP200 Gold LSOH cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS 6425-1: 1990. 2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 077a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2) Certificate No: 077j to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU). Core Construction (excluding drain wire & earth) 7 7, 12 & 19 7 & 12 BS 7629-1 (see Note 2) Complies (1) Complies (1) Complies (1) LPCB Ref. No. 077j/01

FP200 Flex
Nominal csa of conductor (mm2) 1.0 1.5 2.5 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997, the FP200 Flex cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS 6425-1: 1990. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (see Note 2) Complies (1) Complies (1) Complies (1) LPCB Ref. No. 077j/02

12 Sep 2011

409

PART 1: SECTION 8
FIRE RESISTANT CABLES
2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 077a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2) Certificate No: 077k to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30 & PH60 and BS 5839-1: 2002 Clause 26.2d

FP200 Gold LSOH


Nominal csa of conductor (mm2) 1.0 1.5 2.5 4.0 Uo/U 300/500V Notes: 1) In meeting the requirements of BS 7629-1: 1997, the FP200 Gold LSOH cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS 6425-1: 1990. 2) The FP200 Gold LSOH cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water tests described in Clause 26.2 d) of BS 5839-1: 2002 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. 3) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 077f covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2) Certificate No: 077g to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min & BS 5839-1: 2002 Clause 26.2e Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (see Note 3) Complies (1) Complies (1) Complies (1) Complies (1) BS EN 50200 BS 5839-1 Clause 26.2 Standard (2) Standard (2) Standard (2) Standard (2) LPCB Ref. No.

Class PH30 Class PH30 & PH60 Class PH30 & PH60 Class PH30 & PH60

077k/01

FP Plus
Nominal csa of conductor (mm 2) 1.5 2.5 Core Construction (excluding drain wire & earth) 2 2 BS 7629-1 (Incoporating Amendments Nos. 1 & 2) Complies(2) Complies
(2)

BS EN 50200 Class PH120 Class PH120

BS 84342 120min 120min

BS 5839-1 Clause 26.2 Enhanced Enhanced

LPCB Ref. No. 077g/02

Uo/U 300/500V Notes: 1) Solid conductor only. 2) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP Plus cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. 3) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 4) The FP Plus cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met the 120min duration when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 077m to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

410

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES FP600
Nominal csa of conductor (mm 2) 4.0(1) 6.0(1) 10(1) 16(1) 25(1) 35(1) 50(1) 70(1) Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In achieving 120min fire survival time in accordance with BS 7346-6: 2005, the FP600 cables listed also achieved a 120min fire survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346: 2005 Annex B. Certificate No: 077n to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005 Core construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7346-6 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min BS 8491 (fire survival time see note 2) 120min 120min 120min 120min 120min 120min 120min 120min BS EN 50267-2-1 <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% LPCB Ref. No. 077m/01

FP600S
Nominal csa of conductor (mm 2) 2.5(1) 4.0(1) 6.0(1) 10(1) 16(1) 25(1) 35(1) 50(1) 70(1) Uo/U 600/1000V Notes: 1) 2) 3) Stranded conductor only. All 2 core cables have the blue core designated as a Neutral conductor; only phase to earth voltage was applied. In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the FP600S cables listed also achieved a 120min fire survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B. Core construction (see note 2) 7 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2&3 BS 7346-6 (fire survival time) 120min 120min 120min 120min 120min 120min 120min 120min 120min BS 8491 (fire survival time see note 3) 120min 120min 120min 120min 120min 120min 120min 120min 120min BS EN 50267-2-1 <0.5%HCl <0.5%HCl <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI BS EN 61034-2 >60% >60% >60% >60% >60% >60% >60% >60% >60% LPCB Ref. No. 077n/01

Prysmian Power Cables & Systems Australia Pty Limited


1 Heathcote Road, Liverpool, Sydney, New South Wales 2170, Australia Tel: +61 2 9600 0777 Fax: +61 2 9600 0303 Website: www.pirelli.com
Certificate No: 422a to BS 6387: 1994 and BS EN 50267-2-1: 1999

FIRESTOP FS-90 Single Core Cable


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 Core Construction One( 1,2) One( 1,2) One( 1,2) One(1) One(1) BS 6387 (See notes 3, 4 & 5) C C C C C BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No. 422a/01

12 Sep 2011

411

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm2) 16 25 35 50 70 95 120 150 185 240 300 Uo/U 450/750V Notes : 1) Approved for the CEC01QGR series construction. 2) Approved for the CEC01QAZ series construction. 3) Clause 8 (Bending) and 9.1 & 9.2 (Impact) of the BS 6387 standard cannot be conducted due to the cable having only one core. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 20mm and 38mm steel conduit as the other metallic element. 5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. Certificate No: 422b to BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction One(1) One(1) One(1) One(1) One(1) One(1) One(1) One(1) One(1) One(1) One(1) BS 6387 (See notes 3, 4 & 5) C C C C C C C C C C C BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No.

FIRESTOP FS-90 Multicore Cable


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 400 Uo/U 450/750V Notes: 1) Approved for CEC04QMR series construction. 2) Approved for REC04QMR series construction. Core Construction (See notes 1,2) 4(1) 4(1) 4(1) 4(1) 4(1) 4(1) 4(1) 4(1) 4(1,2) 4(1,2) 4(1,2) 4(1,2) 4(1,2) 4(1,2) 4(1,2) 4(1,2) 4(2) BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No. 422b/01

RAMCRO S.p.A
Via Marzorati, 15 - 20014 Nerviano, Milan, Italy Tel: +39 0331 406560 Fax: +39 0331 406559 E-mail: ramcro@ramcro.it
Certificate No: 568a to BS 6387: 1994 and BS EN 50267-2-1: 1999

Ramfirecro-F3
Nominal csa of conductor (mm2) 1.0(1) 1.5(1) 2.5(1) Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 6387 C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 568a/01

412

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm2) 4.0(2) Uo/U 300/500V Notes: 1) Solid and stranded conductors. 2) Stranded conductor only. Certificate No: 568b to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min & BS 5839-1:2002 Clause 26.2d Core Construction 2, 3 & 4 BS 6387 C, W, Z BS EN 50267-2-1 (outer covering) <0.5%HCI LPCB Ref. No.

Ramfirecro-F3 Standard
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 (1) 4.0 (2) Uo/U 300/500V Notes: 1) Solid and Stranded conductors. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997, the Ramfirecro-F3 Standard cables listed met the requirements of smoke density of BS 7622-2: 1993 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS 6425-1: 1990. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002. 5) The Ramfirecro-F3 Standard cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. 6) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 568c covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2) Core Construction (excluding drain wire & earth) 2 ,3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (see note 6) Complies (3) Complies (3) Complies (3) Complies (3) BS EN 50200 BS 8434-1 BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard (5) LPCB Ref. No.

Class PH30 Class PH30 Class PH30 Class PH30

30min (4) 30min (4) 30min (4) 30min (4)

568b/01

Certificate No: 568c to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

Ramfirecro-F3 Standard
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 (1) 4.0 (2) Uo/U 300/500V Notes: 1) Solid and Stranded conductors. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the Ramfirecro-F3 Standard cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 BS 84341 BS 5839-1 Clause 26.2 Standard (5) Standard (5) Standard (5) Standard (5) LPCB Ref. No.

Class PH30 Class PH30 Class PH30 Class PH30

30min (4) 30min (4) 30min (4) 30min (4)

568c/01

12 Sep 2011

413

PART 1: SECTION 8
FIRE RESISTANT CABLES
4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 5) The Ramfirecro-F3 Standard cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 568d to IEC 60331-21: 1999, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005

Ramfirecro-F3 IEC 60331


Nominal csa of conductor (mm) 1.0(1) 1.5(1) 2.5(1) Uo/U 300/500V Notes: 1) Solid and Stranded conductors. Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 IEC 60331-21 Complies Complies Complies BS EN 50267-2-1 <0.5% HCl <0.5% HCl <0.5% HCl BS EN 61034-2 >60% >60% >60% LPCB Ref. No. 568d/01

Shakun Polymers Limited


(Cable Division), Plot No. 4, Silver Industrial Estate, Bhimpore, Patalia Road, Daman 396 210, India Tel: +91 260 222 1538 Fax: +91 260 222 1199 E-mail: technical@shakunpolymers.com Website: www.shakuncables.com
Certificate No: 978a to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d Nominal csa of conductor (mm2 1.5(1) Uo/U 300/500V Note 1: Note 2: Note 3: Note 4: Solid conductor only. In meeting the requirements of BS 7629-1: 2008, the FrTek cable listed met the requirements of smoke density of BS EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. The FrTek cable listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core construction (excluding drain wire and earth) 2 BS 7629-1 Complies(2) BS6387 C,W,Z BS EN 50200 Class PH30 BS EN 50500 Annex E 30min(3) BS 5839-1 Clause 26:2 Standard(4) LPCB Ref. No. 978a/01

SHIELD FIRE, SAFETY & SECURITY LTD


28th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United Kingdom Tel: +44 161 257 2541 Fax: +44 161 225 8817 E-mail: dorota@xportsales.com Website: www.xportsales.com
Certificate No: 682a-(cl-5) to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2d, BS EN 50200: 2006 Annex E and BS EN 50200: 2006 Class PH120 Nominal csa of conductor (mm) 1.0(1) Core construction (excluding drain wire & earth) 2, 3 & 4 BS 7629-1 Complies(3) BS EN 50200 Class PH120 BS EN 50200 Annex E 30min(4) BS 58391Clause 26.2 Standard(5) LPCB Ref. No. 682a/01

414

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm) 1.5(1) 2.5(1) 4.0(2) Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2 BS 7629-1 Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH120 Class PH120 Class PH120 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) BS 58391Clause 26.2 Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Uo/U 300/500V Note 1: Note 2: Note 3: Note 4: Note 5: Solid conductor only. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the Shield-UK cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape and insulation when tested in accordance with BS EN 50267-2-1: 1999. The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. The Shield-UK cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Suzhou Cableplus Technologies Co., Ltd.


No.7, Nanxin Road, Changkun Industrial Park, Shajiabang, Changshu, Jiangsu 215542, China Tel: +86 512 5257 8665 Fax: +86 512 5257 1665 E-mail: info@cableplus-sz.com Website: www.cableplus-sz.com
Certificate No: 827a to BS 6387: 1994 and BS EN 50267-2-1: 1999

Firepro
Nominal csa of conductor (mm) 1.5(1) 2.5(1) 4.0(1) 6.0(1) 10(1) 16(1) Uo/U 450/750V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 6) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. Core Construction One(3) One(3) One(3) One(3) One(4, 5) One(4, 5) BS 6387 (see note 2 & 6) C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl LPCB Ref. No. 827a/01

Tai Sin Electric Limited


24 Gul Crescent, Jurong Town, Singapore 629531, Singapore Tel: +65 6861 3401 Fax: +65 6861 4084 E-mail: kokfong@taisin.com.sg Website: www.taisin.com.sg
Certificate No: 982a to BS 7629-1: 2008, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

12 Sep 2011

415

PART 1: SECTION 8
FIRE RESISTANT CABLES FRA-XOL (E)
Nominal csa of conductor (mm 2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500V Note 1: Note 2: Note 3: Note 4: Note 5: Solid conductor only. Stranded conductor only. In meeting the requirements of BS 7629-1: 2008, the FRA-XOL (E) cables listed met the requirements of smoke density of BS EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. The FRA-XOL (E) cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core construction (excluding drain wire and earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 Complies(3) Complies(3) Complies(3) Complies(3) BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS 8434-2 120min(4) 120min(4) 120min(4) 120min(4) BS 5839-1 Clause 26.2 Enhanced(5) Enhanced(5) Enhanced(5) Enhanced(5) LPCB Ref. No. 982a/01

Certificate No: 982b to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdication of the European Union (EU), BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

FRA-XOL (E)
Nominal csa of conductor (mm 2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Uo/U 300/500V Note 1: Note 2: Note 3: Note 4: Note 5: Note 6 Solid conductor only. Stranded conductor only. In meeting the requirements of BS 7629-1: 1997, the FRA-XOL (E) cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999. The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase. The FRA-XOL (E) cables listed conform to BS 7629-1: 1997, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Core construction (excluding drain wire and earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (see note 6) Complies(3) Complies(3) Complies(3) Complies(3) BS6387 C,W,Z C,W,Z C,W,Z C,W,Z BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS 8434-2 120min(4) 120min(4) 120min(4) 120min(4) BS 5839-1 Clause 26.2 Enhanced(5) Enhanced(5) Enhanced(5) Enhanced(5) LPCB Ref. No. 982b/01

Certificate 982a covers cables certified in accordance with BS 7629-1: 2008

TELE-FONIKA Kable Sp. z o.o., S.K.A.


ul.Wielicka 114, 30-663 Krakow, Poland Tel: +48 12 652 50 00 Fax: +48 12 652 51 56 E-mail: iso@tfkable.pl Website: www.tfkable.pl
Certificate No: 814b to BS 7629-1: 1997 (Incorporating Amendments. Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: 2002 Clause 26.2e

416

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES FLAME-X 950 Enhanced
Nominal csa of conductor (mm) 1.0(1) 1.5
(1)

Core Construction drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4

BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies(3) Complies


(3)

BS6387

BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120

BS 84342 120min(4) 120min


(4)

BS 5839-1 Clause 26.2 Enhanced(5) Enhanced


(5)

LPCB Ref. No. 814b/01

C,W,Z C,W,Z C,W,Z C,W,Z

2.5(1) 4.0(2)

Complies(3) Complies(3)

120min(4) 120min(4)

Enhanced(5) Enhanced(5)

Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FLAME-X 950 Enhanced cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 5) The FLAME-X 950 Enhanced cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 814a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

FLAME-X 950
Nominal csa of conductor (mm) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 & 2) Complies(3) Complies(3) Complies(3) Complies(3) BS 6387 BS EN 50200 BS 8434-1 BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No.

1.0(1) 1.5(1) 2.5(1) 4.0(2)

C,W,Z C,W,Z C,W,Z C,W,Z

Class PH30 Class PH30 Class PH30 Class PH30

30min(4) 30min(4) 30min(4) 30min(4)

814a/01

Uo/U 300/500V Notes: 1) Solid conductor only 2) Stranded conductor only 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FLAME-X 950 cables listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002. 5) The FLAME-X 950 cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002. Certificate No: 814d to BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2)

FLAME-X 950 Power


Nominal csa of conductor (mm) 1.5 (1) 2.5 (1) 4.0 (1) 6.0 (1) Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No. 814d/01

12 Sep 2011

417

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm) 10(1) 16(1) 25(1) 35 (1) 50 (1) 70(1) 95 (1) 120 (1) 150(1) 185(1) 240(1) 300(1) Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) In meeting the requirements of BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2) Category F2, the FLAME-X Power cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994. Certificate No: 814c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999 Core Construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No.

Flame-X 950 Single


Nominal csa of conductor (mm) 1.5(1) 2.5(1) 4.0 (1) 6.0 (1) 10 (1) 16 (1) 25 (1) 35 (1) 50 (1) 70 (1) 95 (1) 120 (1) 150 (1) 185 (1) 240 (1) 300 (1) 400 (1) 500 (1) Uo/U 600/1000V Notes: 1) Stranded conductor only. 2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element. 5) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the other metallic element. 6) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387. 7) Where a single cable is fitted in a conduit, only phase to earth voltage was applied. 8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950C and at a voltage rating of 600V. Certificate No: 814e to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU). Core Construction One One One One One One One One One One One One One One One One One One BS 6387 (See Notes 2, 6 & 7) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(4,5) C, W, Z(4,5) C, W, Z(4,5) C, W, Z(3) C, W, Z(3) C, W, Z(3) C, W, Z(3) C(4) C(4) C(4) C(4) C(4) C(4) BS EN 50267-2-1 (outer covering) <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl IEC 60331-21 (See Note 8) Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies LPCB Ref. No. 814c/01

FLAME-X-950 Power
Nominal csa of conductor (mm) 1.5(1) 2.5(1) Core construction 2, 3 & 4 2, 3 & 4 BS 7846 notes 2 & 3) F2(2) F2(2) LPCB Ref. No. 814e/01

418

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm) 4.0(1) 6.0(1) 10(1) 16(1) 25(1) 35(1) 50(1) 70(1) 95(1) 120(1) 150(1) 185(1) 240(1) 300(1) Uo/U 600/1000V Notes: 1) 2) 3) Stranded conductor only In meeting the requirements of BS 7846: 2000 Category F2, the FLAME-X Power cables listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994 BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators. Certificate 814d covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2) Core construction 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7846 notes 2 & 3) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) F2(2) LPCB Ref. No.

Tratos Cavi SpA


Via Stadio 2, Pieve S. Stefano 52036, Arezzo, Italy Tel: +39 0575 7941 Fax: +39 0575 798026 E-mail: direzione@tratos.it Website: www.tratos.it
Certificate No: 222a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min & BS 5839-1: 2002 Clause 26.2d

FIRE-safe TW950 Fire Resistant Cable


Nominal csa of conductor (mm2) 1.0 (1) 1.5 (1) 2.5 (2) 4.0 (2) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies (3) Complies (3) Complies (3) Complies (3) BS EN 50200 BS 84341 BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Class PH30 Class PH30 Class PH30 Class PH30

30min(4) 30min(4) 30min(4) 30min(4)

222a/01

Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FIRE-safe TW950 Fire Resistant Cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS 6425-1: 1990. 4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002.

12 Sep 2011

419

PART 1: SECTION 8
FIRE RESISTANT CABLES
5) The FIRE-safe TW950 Fire Resistant Cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 222b to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min & BS 5839-1: 2002 Clause 26.2e

Firesafe Enhanced
Nominal csa of conductor (mm2) 1.0 (1) 1.5
(1)

Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4

BS 7629-1 (Incorporating Amendments Nos. 1 and 2) Complies (3) Complies


(3)

BS EN 50200

BS 84342

BS 5839-1 Clause 26.2 Enhanced


(5)

LPCB Ref. No.

2.5 (2) 4.0


(2)

Complies (3) Complies


(3)

Class PH120 Class PH120 Class PH120 Class PH120

120min (4) 120min


(4)

222b/01

Enhanced
(5)

120min (4) 120min


(4)

Enhanced
(5)

Enhanced
(5)

Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos.1 & 2), the Firesafe Enhanced cables listed met the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002. 5) The Firesafe Enhanced cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos.1 & 2), met Class PH120 when tested in accordance with EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Tyco Thermal Controls Canada Limited


250 West Street, Trenton, Ontario K8V 5S2, Canada Tel: +613 392 6571 Fax: +613 394 3711 Website: www.tycothermal.com
Certificate No: 676a to BS EN 60702-1: 2002, BS 6387: 1994 and BS EN 50267-2-1: 1999

Pyrotenax Bare Mineral Insulated Cable (light duty)


Nominal csa of conductor (mm2) 1.0T 1.0 1.5T 1.5 2.5T 2.5 4.0 Uo/U300/500V T = Twisted light duty Note: 1) The above range is certified in bare construction only. Certificate No: 676a to BS EN 60702-1: 2002, BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction (see note 1) 2 2, 3, 4 & 7 2, 3, 4 2, 3, 4 & 7 2, 3, 4 2, 3, 4 & 7 2 BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 676a/01

420

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES Pyrotenax Bare Mineral Insulated Cable (single core heavy duty)
Nominal csa of conductor (mm2) 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 240 300 Uo 450V Note: 1) The above range is certified in bare construction only. 2) For single core cables, only phase to earth voltage was applied. Certificate No: 676a to BS EN 60702-1: 2002, BS 6387: 1994 and BS EN 50267-2-1: 1999 Core Construction (see note 1) One One One One One One One One One One One One One One One BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 676a/02

Pyrotenax Bare Mineral Insulated Cable (heavy duty)


Nominal csa of conductor (mm2) 1.5 2.5 4.0 6.0 10 16 25 Uo/U 450/750V Note: 1) The above range is certified in bare construction only. Core Construction (see note 1) 2, 3, 4, 7, 12 & 19 2, 3, 4, 7 & 12 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 2, 3, & 4 BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies BS 6387 C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z C, W, Z BS EN 50267-2-1 <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI <0.5%HCI LPCB Ref. No. 676a/03

Tyco Thermal Controls Huzhou Co Limited


Shuanglin Industrial Zone, Nanxun District, Huzhou, Zhejiang Province 313012, China Tel: +86 572 7362100 Fax: +86 572 7362166
Certificate No: 841a to BS EN 60702-1: 2002, BS 6387: 1994, BS 7346-6: 2005 and BS 8491: 2008

Pyrotenax Pyro MI Bare Mineral Insulated Cables (Heavy Duty)


Nominal csa of conductor (mm 2) 1.5 2.5 4.0 6.0 10 16 25(3) 35 50 70 95 Core Construction (see notes 1&2) one, 2, 3, 4, 7, 12 & 19 one, 2, 3, 4, 7, & 12 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one one one one BS EN 60702-1 Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS 7346-6 (fire survival time) 120min BS8491 (fire survival time see note 4) 120min LPCB Ref. No. 841a/01

12 Sep 2011

421

PART 1: SECTION 8
FIRE RESISTANT CABLES
Nominal csa of conductor (mm 2) 120 150 185 240 300 400 Uo/U 450/750V Notes: 1) Solid conductor only. 2) The above cables are certified in bare construction only. 3) BS 7346-6: 2005 and BS 8491: 2008 approval applies to the 25mm2 cable at 4 cores only. 4) In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the Pyrotenax Pyro MI Bare Mineral Insulated Cables (Heavy Duty) listed also achieved a 120min fire survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B. Certificate No: 841b to BS EN 60702-1: 2002, BS 6387: 1994, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003 120min, BS 58391: 2002 Clause 26.2e, BS EN 50267-2-1: 1999, BS 7346-6: 2005 and BS 8491: 2008 Core Construction (see notes 1&2) one one one one one one BS EN 60702-1 Complies Complies Complies Complies Complies Complies BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z BS 7346-6 (fire survival time) 120min 120min 120min 120min BS8491 (fire survival time see note 4) 120min 120min 120min 120min LPCB Ref. No.

Pyrotenax Pyro MI Served Mineral Insulated Cables (Heavy Duty)


Nominal csa of Conductor (mm 2) Core Construction (see notes 1 & 2) BS EN 60702-1 BS 6387 BS EN 50200 BS 8434-2 (see note 4) BS 58391 Clause 26.2 (see note 5) Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced Enhanced BS EN 50267-2-1 (outer covering) BS 73466 (fire survival time see note 7) 120min 120min 120min 120min 120min LPCB Ref. No.

1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 150 185 300 400 Uo/U 450/750V

one, 2, 3, 4, 7, 12 & 19 one, 2, 3, 4, 7 & 12 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one one one one one one one one one

Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies Complies

C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z C,W,Z

Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 Class PH120 -

120min 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min 120min -

<0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl <0.5%HCl

841b/01

Notes: 1) Solid conductor only. 2) The above cables are certified in served construction only. 3) BS EN 50200: 2006, BS 8434-2: 2003 and BS 5839-1: 2002 Clause 26.2 approval applies to the 25mm2 cable at 1 & 2 cores only. 4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002. 5) The Pyrotenax Pyro MI Served Mineral Insulated Cables (Heavy Duty) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

422

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
6) BS 7346-6: 2005 and BS 8491: 2008 approval applies to the 25mm2 cable at 3 & 4 cores only. 7) In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the Pyrotenax Pyro MI Served Mineral Insulated Cables (Heavy Duty) listed also achieved a 120min fire survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B. Certificate No: 841c to BS EN 60702-1: 2002 and BS 6387: 1994

Pyrotenax Pyro MI Bare Mineral Insulated Cables (Light Duty)


Nominal csa of conductor (mm 2) 1.0(1,2) 1.5(1,2) 2.5(1,2) 4.0(1,2) Uo/U 300/500V Notes: 1) 2) Solid conductor only. The above cables are certified in Bare construction only. Core Construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 BS EN 60702-1 Complies Complies Complies Complies BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z LPCB Ref. No. 841c/01

Certificate No: 841d to BS EN 60702-1: 2002, BS 6387: 1994, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003 120min, BS 5839-1: 2002+A2:2008 Clause 26.2e and BS EN 50267-2-1: 1999

Pyrotenax Pyro MI Served Mineral Insulated Cables (Light Duty)


Nominal csa of conductor (mm) 1.0(1,2) 1.5(1,2) 2.5(1,2) 4.0
(1,2)

Core construction 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2

BS EN 60702-1 (see note 3) Complies Complies Complies Complies

BS 6387 C,W,Z C,W,Z C,W,Z C,W,Z

BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120

BS 8434-2 120min 120min 120min 120min

BS 5839-1 Clause 26.2 Enhanced(4) Enhanced(4) Enhanced(4) Enhanced


(4)

BS EN 502672-1 (outer covering) <0.5% HCl <0.5% HCl <0.5% HCl <0.5% HCl

LPCB Ref. No. 841d/01

Uo/U 300/500V Notes: 1) 2) 3) 4) Solid conductor only. The above cables are certified in Served construction only. In meeting the requirements of BS EN 60702-1: 2002, the Pyrotenax Pyro MI Served Mineral Insulated Cables (Light Duty) listed met the requirements of smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997. The Pyrotenax Pyro MI Served Mineral Insulated Cables (Light Duty) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Tyco Thermal Controls UK Ltd


3 Rutherford Road, Stephenson Industrial Estate, Washington, Tyne & Wear NE37 3HX, United Kingdom Tel: +44 (0)191 419 8200 Fax: +44 (0)191 419 8201 E-mail: jjones@tycothermal.com Website: www.tycothermal.com
Certificate No: 063d to BS EN 60702-1: 2002, BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 and BS 5839-1: 2002+A2:2008 Clause 26.2e

12 Sep 2011

423

PART 1: SECTION 8
FIRE RESISTANT CABLES PYRO MI Mineral Insulated Cables
Nominal csa of conductor (mm2) PYRO MI Light Duty 1.0(1,2) 1.5(1,2) 2.5(1,2) 4.0(1,2) PYRO MI Heavy Duty 1.5(1,3) 1.5(1,3) 2.5(1,3) 2.5(1,3) 4.0(1,3) 6.0(1,3) 10(1,3) 16(1,3) 25(1,3) 35(1,3) 50(1,3) 70(1,3) 95(1,3) 120(1,3) 150(1,3) 185(1,3) 240(1,3) 300(1,3) 400(1,3) PYRO MI Twisted Light Duty 1.0T(1,2) 1.5T(1,2) 2.5T(1,2) 4.0T(1,2) Core Construction BS EN 607021 (see note 6) BS 6387 BS EN 502672-1 (outer covering) BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 LPCB Ref. No. 063d/01 2, 3, 4 & 7 2, 3, 4 & 7 2, 3, 4 & 7 2 Complies
(4)

Complies(4) Complies(4) Complies(4)

C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4)

<0.5% HCl

(5)

<0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5)

Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5)

120min

(5)

Enhanced

(5,7)

120min(5) 120min(5) 120min(5)

Enhanced(5,7) Enhanced(5,7) Enhanced(5,7)

one, 2, 3 & 4 7, 12 & 19 one, 2, 3 & 4 7 & 12 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one, 2, 3 & 4 one one one one one one one one one one

Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4)

<0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5)

120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5)

Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7)

2 2, 3 & 4 2 2

Complies(4) Complies(4) Complies(4) Complies(4)

C, W, Z(4) C, W, Z(4) C, W, Z(4) C, W, Z(4)

<0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5)

Class PH120(5) Class PH120(5) Class PH120(5) Class PH120(5)

120min(5) 120min(5) 120min(5) 120min(5)

Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7)

Notes: 1) 2) 3) 4) 5)

Solid conductor only. The PYRO MI Mineral Insulated Light Duty Cables were tested at a voltage rating of 300/500V. The PYRO MI Mineral Insulated Heavy Duty Cables were tested at a voltage rating of 450/750V. Approval applies to the Bare and Served cables. Approval applies to the Served cable only.

424

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES
6) 7) In meeting the requirements of BS EN 60702-1: 2002, the PYRO MI Mineral Insulated Served Cables listed met the requirements of smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997. The PYRO MI Mineral Insulated Served Cables listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Union Cable Company Ltd


Unit 15, Goddard Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1QF, United Kingdom Tel: +44 (0)1928 577 418 Fax: +44 (0)1928 581 099jim@unioncable.co.uk E-mail: sales@unioncable.co.uk Website: www.unioncable.co.uk
Certificate No: 682a-(cl-2) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120,BS EN50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Firetrax Gold
Nominal csa of conductor (mm 2) 1.0 (1) 1.5 (1) 2.5 (1) 4.0 (2) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the Firetrax Gold cables listed met the requirements of smoke density of BS EN 61034-2: 2005 fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1:1999. 4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 5) The Firetrax Gold cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008. Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 BS EN 50200 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Complies(3) Complies(3) Complies(3) Complies(3)

Class PH120 Class PH120 Class PH120 Class PH120

682a/01

Ventcroft Limited
Goddard Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1NQ, United Kingdom Tel: +44 (0)1928 581098 Fax: +44 (0)1928 581099 E-mail: sales@ventcroft.co.uk Website: www.ventcroft.co.uk
Certificate No: 682a to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN 50200:2006 Annex E and BS 58391:2002+A2:2008 Clause 26.2d

NoBurn Platinum
Nominal csa of conductor (mm2) 1.0(1) 1.5(1) 2.5(1) 4.0(2) Core Construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 BS EN 50200 BS EN 50200 Annex E BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No.

Complies(3) Complies(3) Complies(3) Complies(3)

Class PH120 Class PH120 Class PH120 Class PH120

30min(4) 30min(4) 30min(4) 30min(4)

682a/01

12 Sep 2011

425

PART 1: SECTION 8
FIRE RESISTANT CABLES
Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the NoBurn Platinum cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999. 4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase. 5) The NoBurn Platinum cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008.

Wrexham Mineral Cables


Wynnstay Technology Park, Ruabon, Wrexham, Clwyd LL14 6EN, United Kingdom Tel: +44 (0)1978 810789 Fax: +44 (0)1978 821502 E-mail: sales@wrexhammineralcable.com Website: www.wrexhammineralcables.com
Certificate No: 333a to BS EN 60702-1: 2002, BS 6387: 1994, BS 50267-2-1: 1999, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003 120 min and BS 5839-1: 2002+A2:2008 Clause 26.2e

Wrexham Mineral Insulated Cables


Nominal csa of conductor (mm2) WMIC Light Duty 1.0(1,2) 1.5 (1,2) 2.5(1,2) 4.0(1,2) WMIC Heavy Duty 1.5(1,3) 2.5(1,3) 4.0(1,3) 6.0(1,3) 10(1,3) WMIC Twisted Light Duty 1.0T(1,2) 1.5T(1,2) 2.5T(1,2) 4.0T(1,2) Core Construction BS EN 60702-1 (See note 6) BS 6387 BS EN 50267-2-1 (outer covering) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 LPCB Ref. No. 333a/01 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 2, 3 & 4 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) Complies(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4) Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) 120min(5) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7)

2 2, 3 & 4 2 2

Complies(4) Complies(4) Complies(4) Complies(4)

C,W,Z(4) C,W,Z(4) C,W,Z(4) C,W,Z(4)

<0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5) <0.5% HCl(5)

Class/PH120(5) Class/PH120(5) Class/PH120(5) Class/PH120(5)

120min(5) 120min(5) 120min(5) 120min(5)

Enhanced(5,7) Enhanced(5,7) Enhanced(5,7) Enhanced(5,7)

Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7:

Solid conductor only. The Wrexham Mineral Insulated Light Duty Cables were tested at a voltage rating of 300/500V. The Wrexham Mineral Insulated Heavy Duty Cables were tested at a voltage rating of 450/750V. Approval applies to the Bare and Served cables. Approval applies to the Served cable only. In meeting the requirements of BS EN 60702-1: 2002, the Wrexham Mineral Insulated Served Cables listed met the requirements of smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997. The Wrexham Mineral Insulated Served Cables listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434?2: 2003 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839?1: 2002+A2:2008.

426

12 Sep 2011

PART 1: SECTION 8
FIRE RESISTANT CABLES

Zeta Alarm Systems by GLT Exports Limited


Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 Fax: +44 (0)1792 455176 E-mail: ghassan@gltexports.com Website: www.gltexports.com
Certificate No: 330h to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN50200: 2006 Annex E and BS 5839-1: 2002+A2: 2008 Clause 26.2d

Fire Defence
Nominal csa of conductor (mm) 1.0 (1) 1.5 (1) 2.5 (1) 4.02) Uo/U 300/500V Notes: 1) Solid conductor only. 2) Stranded conductor only. 3) In meeting the requirements of BS 7629-1: 2008, the Fire Defence cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1:1999. 4) The duration of 30min when tested in accordance with BS 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase. 5) The Fire Defence cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008. Core construction (excluding drain wire & earth) 2, 3 & 4 2, 3 & 4 2, 3 & 4 2 BS 7629-1 Complies(3) Complies(3) Complies(3) Complies(3) BS EN 50200 Class PH120 Class PH120 Class PH120 Class PH120 BS EN 50200 Annex E 30min(4) 30min(4) 30min(4) 30min(4) BS 5839-1 Clause 26.2 Standard(5) Standard(5) Standard(5) Standard(5) LPCB Ref. No. 330h/01

12 Sep 2011

427

PART 1: SECTION 9
ALARM RECEIVING CENTRES This section lists Alarm Receiving Centres approved to LPS 1020 Requirements for Alarm Receiving Centres and those certified to the requirements of BS 5979 Code of Practice for Remote Centres Receiving Signals from Security Systems. The Fire Services 'Model Agreement' between the Fire and Rescue authorities and users of remotely monitored fire alarm systems calls for third party certification of both the installer and the Alarm Receiving Centre (ARC). The LPCB approval scheme based on the criteria of LPS 1020 when used in conjunction with BS 5979 provides the means to achieve the alarm receiving centre requirement of the model agreement. Third party certification of the installer can be achieved via the LPCBs scheme for installers based, on the requirements of LPS 1014 Requirements for certificated fire detection and alarm systems firms. For further details of the Model Agreement contact:The Chief Fire Officers Association 9-11 Pebble Close Amington Tamworth Staffordshire B77 4RD Tel: +44 (0) 1827 302 300 Since the Alarm receiving centres must have links to the appropriate fire brigade mobilisation centres, the list includes details of the fire authority areas for which they are approved.

Banham Alarms (Prop: Banham Patent Locks Limited)


10 Pascal Street, London SW8 4SH, United Kingdom Tel: +44 (0)207 622 5151 Fax: +44 (0)207 498 2461 Website: www.banham.com
Certificate No. CSFA006 to LPS 1020 Alarm receiving equipment: Telecom Red CARE System. Approved Fire Authority areas of operation: Bedfordshire, Berkshire, Buckinghamshire, East Sussex, Essex, Hampshire, Hertfordshire, Kent, Greater London, Surrey West Sussex.

EMCS - East Midlands Central Station Limited


Waterside House, Tissington Close, Chilwell, Nottingham NG9 6QG, United Kingdom Tel: +44 (0)844 80 999 80 Fax: +44 (0)844 80 999 70 E-mail: admin@emcs.co.uk Website: www.emcs.co.uk
Certificate No. CFSA 017 to LPS 1020 Issue 2.1 Alarm receiving equipment: BT Redcare (Incorporating Classic,GSM,AGILE and ASSURE), CSL Dualcom, Emizon21, Webway One Digital Communicators, (Point Id and SIA communication Protocols) CCTV - Adpro, DM and VDT. Approved fire authority areas of operation: Avon, Bedfordshire, Berkshire, Buckinghamshire, Cambridgeshire, Central Scotland, Cheshire, Cleveland, Cornwall, Cumbria, Derbyshire, Devon, Dorset, Dumfries & Galloway, Durham, Dyfed, East Sussex, Essex, Fife, Gloucestershire, Grampian, Guernsey, Hampshire, Hereford & Worcester, Hertfordshire, Highlands & Islands, Humberside, Isle Of Man, Isle Of Wight, Kent, Lancashire, Leicester, Lincolnshire, London, Lothian & Borders, Manchester, Merseyside, Mid/West Wales, Norfolk, North Wales, North Yorkshire, Northants, Northern Ireland, Northumberland, Oxfordshire, Powys, Shropshire, Somerset, South Wales, South Yorkshire, Staffordshire, Strathclyde, Suffolk, Surrey, West Sussex, Tayside, Tyne & Wear, Warwickshire, West Midlands, West Yorkshire, Wiltshire.

428

12 Sep 2011

PART 1: SECTION 9
ALARM RECEIVING CENTRES

National Monitoring (Prop. AVR Group Limited)


Units 16/24, Attenburys Park Estate, Attenburys Lane, Timperley, Cheshire WA14 5QN, United Kingdom Tel: +44 (0)870 4009998 Fax: +44 (0)870 4009988
Certificate No. CSFA008 to LPS 1020 Alarm receiving equipment: Telecom Red CARE System. Approved fire authority areas of operation: Avon, Bedfordshire, Berkshire, Cambridgeshire, Cheshire, Clwyd, Cumbria, Derbyshire, Devon, Dorset, Essex, Gloucestershire, Hampshire, Hereford & Worcester, Humberside, Lancashire, Leicestershire, Lincolnshire, London, Greater Manchester, Merseyside, Norfolk, Northamptonshire, Northern Ireland, Nottinghamshire, North Yorkshire, Shropshire, South Yorkshire, Staffordshire, Suffolk, Surrey, Tyne and Wear Warwickshire, West Glamorgan, West Midlands, West Yorkshire, Strathclyde.

Security Services (Prop: Bryan Enterprises Ltd.)


2 Berry Street, Stoke on Trent ST4 1AY, United Kingdom Tel: +44 (0)1782 416308 Fax: +44 (0)1782 849522
Certificate No. CSFA007 to LPS 1020 Alarm receiving equipment: Telecom Red CARE System. Approved fire authority areas of operation: Cheshire, Clwyd, Greater Manchester, Gwynedd, Shropshire, Staffordshire, West Midlands

Southern Monitoring Services Limited


Security House, 212-218, London Road, Waterlooville, Hampshire PO7 7AJ, United Kingdom Tel: +44 (0)870 242 220 Fax: +44 (0)870 243 330
Certificate No. CSFA003 to LPS 1020 Alarm receiving equipment: Telecom Red CARE System. Approved fire authority areas of operation: Avon, Bedfordshire, Berkshire, Buckinghamshire, Cambridgeshire, Cheshire, Cleveland, Clwyd, Cornwall, Cumbria, Derbyshire, Devon, Dorset, East Sussex, Essex, Gloucestershire, Grampian, Greater London, Gwent, Hampshire, Hereford & Worcester, Hertfordshire, Humberside, Isle of Wight, Kent, Lancashire, Leicestershire, Lincolnshire, Lothian, Greater Manchester, Merseyside, Mid Glamorgan, Norfolk, Northamptonshire, North Yorkshire, Nottinghamshire, Oxfordshire, Powys, Shropshire, Somerset, South Glamorgan, South Yorkshire, Staffordshire, Strathclyde, Suffolk, Surrey, Tyne & Wear, Warwickshire, West Glamorgan, West Midlands, West Sussex, West Yorkshire, Wiltshire.

12 Sep 2011

429

PART 1: SECTION 10
ALARM TRANSMISSION AND FAULT MONITORING EQUIPMENT AND SIGNALLING SYSTEMS Introduction This section of the Red Book lists alarm transmission and fault routing equipment suitable for use with fire alarm systems as defined by Figure 1 of EN 54-1: 1996 Fire detection and fire alarm systems Part 1. Alarm transmission equipment suitable for use with intruder alarm and hold-up systems are listed in Volume 2 Part 4 Section 1.2 of the Red Book. Where alarm transmission equipment may be suitable for use with both fire alarm systems and intruder alarm and hold-up systems the entry for the approved equipment will appear in Volume 1 Part 1 Section 10 and Volume 2 Part 4 Section 1.2 of the Red Book. Where appropriate, reference is made to published standards and the following standards are currently used for the approval schemes: EN 54-21: 2006 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment

EN 54-21: 2006 is a harmonised standard for the Construction Products Directive. Compliance with the EN standard entitles the equipment manufacturer to apply the CE mark and is mandatory in many countries within the EU. ANNEX ZA of EN 54-21 states that for CE marking purposes it is not necessary to test the alarm transmission and fault routing equipment performance characteristics in conjunction with the transmission networks to confirm the claimed transmission parameters D, M, T, A ,S and I. These parameters are however described in the EN 54-21 normative ANNEX A and may be tested as an option. Unless otherwise stated LPCB approval to EN 54-21 confirms that the routing equipment meets only those requirements of ANNEX ZA relating to the operational and environmental reliability of the item(s) located within the protected premises. Whereas LPS 1277 includes criteria for both fire and security systems that specifically requires the alarm transmission and fault routing equipment to be tested in conjunction with the appropriate transmission networks. Particular emphasis is placed on the verification of manufacturers claims by measuring alarm transmission times over the transmission path(s) between the equipment under test and the corresponding alarm receiving centre. The response to the reporting of fault conditions is measured in a similar way. The results of these measurements are expressed in terms of alarm transmission system (ATS) performance criteria classification, using the parameters D, M, T and where applicable S and I. Where, D = Transmission time classification M = Transmission time maximum values T = Reporting time classification S = Substitution Security I = Information Security Availability is considered a key parameter under LPCB approval and is therefore included within the requirements of LPS 1277 and the resultant performance is expressed using the parameter A for Availability. The actual performance parameters measured during the LPCB test programme are included with the product listing entry in the Redbook as an indicator of the level of performance that can be expected from the alarm transmission system. Products approved to LPS 1277 encompass all of the requirements of EN 54-21 and products tested and approved by the LPCB will have met the compliance criteria of EN 54-21 in full. It is therefore recommended that alarm transmission and fault routing equipment be approved to LPS 1277 where possible.

430

12 Sep 2011

PART 1: SECTION 10
ALARM TRANSMISSION AND FAULT MONITORING EQUIPMENT AND SIGNALLING SYSTEMS Compliance with relevant safety standards and applicable mandatory directives is a pre-requisite of LPCB approval and listing. Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Notes: Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

12 Sep 2011

431

PART 1: SECTION 10.1


ALARM TRANSMISSION AND FAULT ROUTING EQUIPMENT Alarm transmission and fault monitoring equipment approved to the requirements of EN 54-21: 2006 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment. Unless stated otherwise the performance of those components of the alarm transmission and fault monitoring system normally located in the protected premises have been tested and assessed for compliance without connection to the associated alarm transmission networks as prescribed by ANNEX ZA of EN 54-21.

Note: At the time of gong to print no alarm transmission and fault monitoring equipment was listed as compliant with EN 54-21. Please check www.redbooklive.com for updates.

432

12 Sep 2011

PART 1: SECTION 10.2


ALARM TRANSMISSION AND FAULT ROUTING EQUIPMENT AND SYSTEMS Alarm transmission equipment approved to LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment Requirements and tests are included in the Loss Prevention Standard that enables the assessment of the performance of those components of the alarm transmission system normally located in the protected premises when used in conjunction with the appropriate transmission networks. Specifiers are advised to check the issue of LPS 1277 against which the alarm transmission equipment is approved. At the time of going to print the current publication of LPS 1277 was Issue 3.

BT Redcare
Monument TE, 11-13 Great Tower Street, London EC3R 5EA, United Kingdom Tel: +44 (0) 800 800 828 Fax: +44 (0)20 7929 6490 Website: www.redcare.bt.com
Certificate No: 775a to LPS 1277: Issue 2.2 Product Name UC-372G-UK ASSURE STAR Fire Category B Security Grade 3 Primary Transmission Path Asynchronous digital subscriber line (ASDL) operated by BT Broadband Secondary Transmission Path General packet radio service (GRPS) on a BT mobile network LPCB Ref. No. 775a/01

Performance Parameters Transmission Transmission Path Time Classification Primary D4


Secondary Combined1 D4 D4

Transmission Time Max. Values M32 M32 M32

Reporting Time Classification T5 T33 T54

Substitution Security S2 S2 S2

Information Security I3 I3 I3

Network Availability5 A3 A1 A3

Approved Ancillaries AO100 External base antenna (short) BA900-5 High gain antenna (long) CAB0106 10m low loss extension cable UltraCapture8 Video Card UltraCapture4 Video Card Notes: 1) The combined performance parameters are shown for the ASSURE STAR as a whole, i.e. with both primary and secondary transmission paths operational. The alarm transmission performance parameters of the ASSURE STAR are consistent with those of ATS 5. 2) During a planned maintenance procedure the ASSURE STAR will achieve performance classification D4 at a maximum transmission time classification M2. The maintenance procedure will be operated approximately four times per year and will be of approximately 5 minutes duration. 3) The loss of the secondary path following a previous failure of the primary path results in a reporting time classification of T4. 4) The simultaneous loss of the primary and secondary transmission paths results in a reporting time classification of T5. 5) Network availability classifications have been based on the limited availability data. At the time of the initial evaluation only a limited number of ASSURE STAR alarm transmission equipment were in service and these were subject to interruption due to engineering trials whilst the data was being recorded. The monitoring of network availability continues and the classification will be updated when available. When operating with both transmission paths functioning correctly the combined system availability will meet classification A3.

12 Sep 2011

433

PART 1: SECTION 10.2


ALARM TRANSMISSION AND FAULT ROUTING EQUIPMENT AND SYSTEMS

CSL DualCom Limited


Salamander Quay West, Park Lane, Harefield, Middlesex UB8 6NZ, United Kingdom Tel: +44 (0)1895 474474 Fax: +44 (0)1895 474440 E-mail: sales@csldual.com Website: www.csldual.com
Certificate No: 723a to LPS 1277: Issue 2.2 Certificated Products CS 1400 DualCom Fire Alarm Transmission Equipment (Ancillaries CS 1050, CS1053) LPCB Ref. No. 723a/01

Note: Meets the requirements of LPS 1277 for Category B fire alarm transmission equipment. The DualCom Fire has two transmission paths, a primary path signalling over the Packet Data Radio Network operated by Vodafone Ltd., and a secondary path operating over the Public Switched Telephone Network

Alarm transmission system performance parameters Transmission Transmission time Transmission Reporting time Path classification time classification Max. values M3 <90s1

Network availability

Primary Secondary

D4 D3

T3 T52

A4 A4

Notes: 1) Equivalent to M2 of EN 50136-1-1:1998 2) The simultaneous loss of the primary and secondary transmission paths results in a reporting time classification of T3 Approved with the following Ancillaries CS 1050 DualCom 8 Channel Expander CS 1053 DualCom High gain aerial

WebWayOne Ltd
11 Kingfisher Court, Hambridge Road, Newbury, Berkshire RG14 5SJ, United Kingdom Tel: +44 (0)1635 231500 Fax: +44 (0)1635 231539 E-mail: sales@webwayone.co.uk Website: www.webwayone.co.uk
Certificate No: 1022a/01 & 02 to LPS 1277: Issue 3.0

Alarm transmission and fault routing equipment


Certificated Products 22-5005 WebWay IP/GPRS LPS Fire Type 1 22-5015 WebWay GPRS/PSTN LPS Fire Type 2 The WebWay IP/GPRS LPS Fire Type 1 1) Alarm transmission and fault routing equipment comprises equipment part no. 22-5005 plus configuration part no. '1411AD155001. The WebWay GPRS/PSTN LPS Fire Type 2 1) Alarm transmission and fault routing equipment comprises equipment part no. 22-5015 plus configuration part no. '1411AD155003. LPCB Ref. No. 1022a/01 1022a/02

Approved with the following Ancillaries 22-5054 High performance disc antenna 22-5049-5m High gain extension antenna with 5 metre cable 22-5049-10m High gain extension antenna with 10 metre cable 22-5049-15m High gain extension antenna with 15 metre cable 22-5049-20m High gain extension antenna with 20 metre cable 22-5076 PSTN Dialler PCB module 22-5073 RS232 Serial interface module2) 22-5076 Modem capture alarm panel interface module2)

434

12 Sep 2011

PART 1: SECTION 10.2


ALARM TRANSMISSION AND FAULT ROUTING EQUIPMENT AND SYSTEMS
1)

The alarm transmission and fault routing equipment is to be used in accordance with the installation instructions and in conjunction with fire alarm control and indicating equipment compliant with EN 54-2 and capable of meeting options with requirements associated with Clause 7.9, 8.2.4(g), 8.2.5(b), 8.9, 9.4.1(c), 9.4.2(b), 10.1(e), 11(a) and 11(b). Fire alarm and fire fault or trouble signals from the alarm panel must be connected via PIN inputs. The PIN inputs shall be programmed as End of Line (EOL). The 22-5005 WebWay IP/GPRS LPS Fire Type 1 shall be housed within a metallic enclosure providing protection against ingress to IP30 at access level 2 and be connected to an integral power supply compliant with EN 54-4.

2)

Fire alarm, fire fault or trouble messages must be transmitted using the PIN interfaces.

The performance of the above listed products has been found to meet the fire detection and alarm system requirements of LPS 1277 Issue 3.0 with the following performance parameters: Alarm Transmission System Performance Parameters 22-5005 WebWay IP/GPRS LPS Fire Type 1

LPCB Product Name Fire Category Performance Classification N/A

Designated T ransmission Paths Cert No Primary Broadband (IP) Secondary Duplicate

WebWay IP/GPRS LPS Fire Type 1

EN54-21 Type 1

GPRS

N/A

1022a/01

Confirmed Performance Parameters

Transmission time Classification D4


3) 4)

Transmission time Max. Values M3

Reporting time Classification3) T5

Substitution Security S2

Information Security I3

Netw ork Availability 4) A4

Enhanced Performance Rating N/A

Primary path reporting time Network Availability confirmed with both designated primary and secondary paths operating.

ATS path failure

ATS path failure conditions Loss of Primary path only (i.e. secondary path remaining operational) Loss of Secondary path only (i.e. primary path remaining operational) Loss of Secondary path w hilst operating w ithout Primary path (i.e. the loss of Secondary path some time after a previous loss of the Primary path).

Reporting Time Classification T5 T3 T5

Reporting catastrophic 5) failure of ATS


5)

T4

The detected loss of the primary path followed by immediate detection of loss of the Secondary path.

____________________________________________________________________________________________ 22-5015 WebWay GPRS/PSTN LPS Fire Type 2

Product Name

Fire Category

LPCB Performance Classification

Designated T ransmission Paths Cert No Primary Secondary Duplicate

WebWay GPRS/PSTN LPS Fire Type 2

EN54-21 Type 2

N/A

GPRS

PSTN

N/A

1022a/02

Confirmed Performance Parameters

12 Sep 2011

435

PART 1: SECTION 10.2


ALARM TRANSMISSION AND FAULT ROUTING EQUIPMENT AND SYSTEMS
Transmission time Classification D3
3) 4)

Transmission time Max. Values M3

Reporting time Classification3) T 3 Plus

Substitution Security S2

Information Security

Netw ork Availability 4) A4

Enhanced Performance Rating N/A

I3

Primary path reporting time. Network Availability confirmed with both designated primary and secondary paths operating.

ATS path failure

ATS path failure conditions Loss of Primary path only (i.e. secondary path remaining operational) Loss of Secondary path only (i.e. primary path remaining operational) Loss of Secondary path w hilst operating w ithout Primary path (i.e. the loss of Secondary path some time after a previous loss of the Primary path).

Reporting Time Classification T3Plus T3 T3

Reporting catastrophic 5) failure of ATS


5)

T3

The detected loss of the primary path followed by immediate detection of loss of the Secondary path.

436

12 Sep 2011

PART 1: SECTION 10.3


SIGNALLING SYSTEMS In previous editions of the Red Book this section listed alarm signalling systems approved to special requirements developed by LPCB, prior to the publication of LPS 1277 and EN-54-21. The approval of these products has now expired and has been replaced by approval of products to LPS 1277 and EN-54-21. Please refer to Part 1:Section 10.1 'Alarm Transmission and fault routing equipment' for a list of equipment approved to EN 54-21or Part 1:Section 10.2 'Alarm Transmission and fault routing equipment and systems' for a list of equipment approved to LPS 1277.

BT Redcare
Monument TE, 11-13 Great Tower Street, London EC3R 5EA, United Kingdom Tel: +44 (0) 800 800 828 Fax: +44 (0)20 7929 6490 Website: www.redcare.bt.com
Certificate No: 099a Certificated Products 3GSTU-12V 3GSTU-24V LPCB Ref. No. n/a n/a

Note to Specifiers In January 2008 Red Book entries for the BT Redcare 3GSTU-12V and 3GSTU-24V alarm transmission equipment were removed because the scheme against which these products were approved had been superseded by LPS 1277. LPCB assessment of the quality management system associated with production of the 3GSTU-12V and 3GSTU-24V has been maintained and both products, now referred to as 'Classic STU' and 'Fire STU', are currently being evaluated to LPS 1277. Red Book listing will be reinstated once compliance with the requirements of LPS 1277 has been successfully demonstrated.

12 Sep 2011

437