You are on page 1of 10

CALCULO DE ARMADURA DE RESERVORIO

DATOS
PROYECTO :AGUA POTABLE CCOMAYO

ACERO MUROS
ACERO VERTICAL
= 3/8
DIAMETRO
= 0.953
AREA
= 0.713
PESO
= 0.560
ACERO HORIZONTAL = 3/8
DIAMETRO
= 0.953
AREA
= 0.713
PESO
= 0.560

EXPEDIENTE :
ZONAL
: CANAS
EVALUADOR :CARLOS L
FECHA
: 6-May-12

CARACTERISTICAS GEOMETRICAS
VOLUMEN RESERVORIO

5.00

m3

ALTURA UTIL RESERVORIO =


1.25
LADO UTIL RESERVORIO
=
2.00
ESPECIFICACIONES

mts.
mts.

CONCRETO f'c
SOBRECARGA EN LOSA
ACERO fy
RESISTENCIA DEL SUELO

=
=
=
=

175
150
4,200
1.00

COEF. SISMICO
RECUBRIMIENTO r =
fs
fc

=
=
=
=

0.12
4.00 Cm
2,100 Kg/cm2
78.8 Kg/cm2

ACERO LOSA DE TECHO


ACERO HORIZONTAL = 3/8
DIAMETRO
= 0.953
AREA
= 0.713
PESO
= 0.560
ACERO LOSA DE FONDO
ACERO HORIZONTAL = 3/8
DIAMETRO
= 0.953
AREA
= 0.713
PESO
= 0.560

Kg/cm2
Kg/m2
Kg/cm2
Kg/cm2

0.20

0.15

Pulg.
Cms.
Cms2.
Kg/ml
Pulg.
Cms.
Cms2.
Kg/ml

Pulg.
Cms.
Cms2.
Kg/ml
Pulg.
Cms.
Cms2.
Kg/ml

1.00

1.35
1.35

Sc
SL
A'

Wc
0.10

B'
0.30
WL

NIVEL DE AGUA

S1
1.25
Ea
1.85

1.80

W1

0.4

0.98

Wa
A

B
S2

0.20

0.10
C

W2
0.28
0.68
0.85

CALCULOS
W1= Pc x V1
W2 = Pc x V2

558.00 Kg
648.00 Kg

Wa = Pa x Va
WL = Pc x VL

1250.00
276.00
172.50
100.44

Ws = Sc x A
S1 = 0,12 x W1
S2 = 0,12 x W2
SL = 0,12 x WL
Ss = 0,12 x Ws

Kg
Kg
Kg
Kg

116.64 Kg
49.68 Kg
37.26 Kg

1312.50 Kg

Ea = 1,12 x 0,5 x Pa x H12

VERIFICACION DEL ESFUERZO CORTANTE EN LA BASE AB


V = Fh / A

1.00 Kg/cm2

Vc = 0,29 ( f'c )^1/2

3.84 Kg/cm2
V=

1.00

Kg/cm2

<

Vc =

3.84

Kg/cm2BIEN !!

CALCULO DE LA ARMADURA
ACERO VERTICAL CARA B'-B
MOMENTO MAXIMO EN LA BASE A-B
Mu
d = t1 - r - D/2

765.68 Kg-mts.
10.52 Cms.

AREA DE ACERO
As1 =
72.56 Cms2
As2 =
1.98 Cms2

SE ASUME :

0.0013

CUANTIA = As / t1 x b
CUANTIA MINIMA POR FLEXION 0.0012
USAR :

1.98 Cms2

3/8

<

0.0013

BIEN!!

0.30 mts.

ACERO HORIZONTAL B'B


ASUMIR CUANTIA MINIMA PARA EL ACERO HORIZONTAL, CONSIDERANDO P = 0,0018
As = P x b x t1
USAR :

2.70 Cms2

3/8

0.26 mts.

ACERO EN LA ZAPATA
ASUMIR EL AREA DE ACERO HALLADA PARA LA BASE DE MURO
USAR :

3/8

0.30 mts.

ACERO EN LA LOSA DE FONDO


P1
P2
P3
P4
P5
LUEGO:

1904.4
3850.2
3348.00
5248.80
7500.00
WuD :
WuL :

4130.70
270.00
Wu :

4400.70

CALCULO DEL MOMENTO ULTIMO


Mu = 0,0513 * Wu * L2
d = t1 - r - D/2

1194.25 Kg--mts
15.52 Cms.

AREA DE ACERO
As1 =
107.88 Cms2
As2 =
2.07 Cms2

SE ASUME :

0.001

CUANTIA = As / t1 x b
CUANTIA MINIMA POR FLEXION 0.0012
USAR :

2.07 Cms2

3/8

>

0.0010

MAL!!

0.25 mts.

ACERO EN LA LOSA DE TECHO


WuD = 2400 * t1 * 1,5
WuL = SC * 1,8

360
270
630

Wu =
CALCULO DEL MOMENTO ULTIMO
Mu = 0,0479 * Wu * L2
d = t1 - r - D/2
AREA DE ACERO
As1 =
39.95 Cms2
As2 =
0.57 Cms2

120.71 Kg--mts
5.72 Cms.

SE ASUME :

0.57 Cms2

0.0006

CUANTIA = As / t1 x b

CUANTIA MINIMA POR FLEXION 0.0012

>

0.0006 MAL!! SE ASUME CUANTIA MINIMA P= 0.0012

As = P * t1 * b

USAR :

1.20 Cms2

3/8

0.25 mts

2.70
0.15

0.20

0.30

0.15

TUB. FG 3/4"
@ 0,30 Mts.

0.15

1.5

UNIONES
ELECTROSOLDADAS

0.10

2.00

ESCALINES FG
VER DETALLE

DETALLE DE ESCALINES

BUZON 0,60 x 0,60 Mts.


TAPA SANITARIA METALICA

ESPECIFICACIONES TECNICAS
0.15

0.20

0.20

0.15

2.00

0.15

RESISTENCIA DEL CONCRETO

f'c

175

Kg/cm2

FLUENCIA DEL ACERO

fy

4200

Kg/cm2

30

TRASLAPE MINIMO DE VARILLAS

cm

0.20

FONCODES
RESERVORIO APOYADO

5 M3

PLANTA
C. LOAYZA P.

May-12

TAPA SANITARIA METALICA


0,60 x 0,60 mts.

3/8

TUBERIA DE VENTILACION FG 2"

0.25

0.10

0.30
NIVEL DE AGUA

3/8

0.30

3/8

0.26

1.55

TARRAJEO C / IMPERMEABILIZANTE

1.25

3/8

0.30

3/8

3/8

0.25

PENDIENTE DE FONDO 1%

0.30

0.20

0.075

0.67

0.20

0.15

SOLADO DE CONCRETO

2.00

0.15

0.20

FONCODES
RESERVORIO APOYADO
CORTE A-A
C. LOAYZA P.

5 M3

May-12

3/8

0.25

3/8

2.30

ESPECIFICACIONES TECNICAS
RESISTENCIA DEL CONCRETO

f'c

175

Kg/cm2

FLUENCIA DEL ACERO

fy

4200

Kg/cm2

30

TRASLAPE MINIMO DE VARILLAS

2.30

cm

FONCODES
RESERVORIO APOYADO

5 M3

ARMADURA DE LOSA DE TECHO


C. LOAYZA P.

May-12

PLANILLA DE ARMADURA RESERVORIO

5 M3

ARMADURA LOSA DE TECHO

LONGITUD

VECES

PESO

3/8

2.38

20.4

27.19

3/8

2.24

5.02

LONGITUD

VECES

PESO

3/8

1.19

40.00

26.58

3/8

2.64

12.89

19.05

LONGITUD

VECES

PESO

3/8

1.93

34.67

37.47

3/8

4.75

13.92

37.04

2.24
0.07

2.24

ARMADURA LOSA DE FONDO


1.02
0.17

2.64

ARMADURA DE MURO
0.11

1.71

0.15

2.15

1.15

PESO TOTAL EN Kg

152.35

HOJA DE METRADOS DE RESERVORIO


CAPACIDAD :
PROYEC.:
EXPED.:
PARTIDA

6.00
6.01
6.02
6.03
6.04

6.05
6.06

6.07
6.08

6.09
6.10
6.11
6.12
6.13
6.14
6.15

AGUA POTABLE CCOMAYO


0

EVALUADOR:
FECHA:

DESCRIPCION

VECES

RESERVORIO
TRAZO Y REPLANTEO
EXCAVACION MANUAL
SOLADO DE CONCRETO E= 0.05 Mts.
CONCRETO F'C= 175 KG/CM2

5.00
1.00
1.00
1.00
1.00
2.00
2.00
1.00
CONFOR. DE PENDIENTE DE FONDO C F'C= 175 KG/CM21.00
ENCOFRADO Y DESENCOFRADO
4.00
4.00
1.00
ACERO FY= 4,200 KG/CM2
1.00
ESCALINES DE FIERRO GALVANIZADO
2.00
4.00
TARRAJEO INTERIOR CON IMPERMEABILIZANTE
TARRAJEO EXTERIOR MEZCLA 1:5
TAPA SANITARIA METALICA 0,60 x 0,60 Mts.
TUBERIA DE VENTILACION FG D= 2"
PRUEBA HIDRAULICA Y DESINFEC. RESERVORIO
SUMINISTRO Y COLOCACION DE HIPOCLORADOR
PINTADO DE MUROS EXTERIORES

LONG.

ANCHO

ALTURA

M3

CARLOS L
5/6/2012
SUB-TOTAL

TOTAL

2.70
2.70
2.70
2.70
2.30
2.00
2.30
2.00
2.30
2.00
2.00
152.35
2.05
0.30

4.00
1.00
4.00
1.00
1.00
1.00
1.00
1.00
4.00
1.00

2.00
2.00
2.30
2.30

2.30
2.30

2.70
2.70
2.70
2.70
0.15
0.15
2.30
2.00

0.80
0.20
1.55
1.55
0.10
1.65
1.55

2.00

1.55
2.00
1.65
2.30

1.65
2.30

7.29
5.83
7.29
1.46
1.07
0.93
0.53
4.00
15.18
12.40
4.00
152.35
4.10
1.20
12.40
4.00
15.18
5.29
1.00
1.00
1.00
1.00
15.18
5.29

7.29
5.83
7.29
3.99

4.00
31.58

152.35
5.30

16.40
20.47
1.00
1.00
1.00
1.00
20.47

TIEMPO DE EJECUCION DE OBRA


PARTIDA

6.00
6.01
6.02
6.03
6.04
6.05
6.06
6.07
6.08
6.09
6.10
6.11
6.12
6.13
6.14
6.15

DESCRIPCION

UNID

RESERVORIO
5.00
TRAZO Y REPLANTEO
m2
EXCAVACION MANUAL
m3
SOLADO DE CONCRETO E= 0.05 Mts.
m3
CONCRETO F'C= 175 KG/CM2
m3
CONFOR. DE PENDIENTE DE FONDO C F'C= 175 KG/CM2
m2
ENCOFRADO Y DESENCOFRADO
m2
ACERO FY= 4,200 KG/CM2
kg
ESCALINES DE FIERRO GALVANIZADO
ml
TARRAJEO INTERIOR CON IMPERMEABILIZANTE
m2
TARRAJEO EXTERIOR MEZCLA 1:5
m2
TAPA SANITARIA METALICA 0,60 x 0,60 Mts.
und
TUBERIA DE VENTILACION FG D= 2"
und
PRUEBA HIDRAULICA Y DESINFEC. RESERVORIO
glb
SUMINISTRO Y COLOCACION DE HIPOCLORADOR
und
PINTADO DE MUROS EXTERIORES
m2

UNID.

M3

METRADO

RENDI.

PERSONAL

PERSONAL BASE

TIEMPO

M3

7.29
5.83
7.29
3.99
4.00
31.58
152.35
5.30
16.40
20.47
1.00
1.00
1.00
1.00
20.47

200.00
3.00
70.00
9.00
70.00
10.00
250.00
15.00
6.00
10.00
5.00
10.00
10.00
10.00
25.00

1.00
1.00
2.00
2.00
2.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

1.00
5.00
2.00
2.00
2.00
5.00
1.00
1.00
2.00
2.00
1.00
1.00
1.00
1.00
1.00

0.29
3.11
0.83
3.54
0.46
5.05
4.88
2.83
10.93
8.19
1.60
0.80
0.80
0.80
6.55
6.33

m2
m3
m2
m3
m3
m3
m3
m2
m2
m2
m2
kg
ml

m2
m2
m2
m2
unid
unid
glb
unid
m2

VOLUMEN

ALTURA

LADO INTER

3.00
4.00
5.00

1.25
1.25
1.25

1.55
1.80
2.00

6.00
7.00
8.00
9.00
10.00
11.00
12.00
13.00
14.00
15.00
16.00
17.00
18.00
19.00
20.00
21.00
22.00
23.00
24.00
25.00
26.00
27.00
28.00
29.00
30.00
31.00
32.00
33.00
34.00
35.00
36.00
37.00
38.00
39.00
40.00
41.00
42.00
43.00
44.00
45.00
46.00
47.00
48.00
49.00
50.00
51.00
52.00
53.00
54.00
55.00
56.00
57.00
58.00
59.00
60.00

1.25
1.25
1.30
1.30
1.35
1.40
1.45
1.50
1.55
1.55
1.60
1.65
1.65
1.70
1.70
1.75
1.75
1.80
1.85
1.85
1.85
1.90
1.90
1.95
1.95
2.00
2.00
2.05
2.05
2.05
2.10
2.10
2.15
2.15
2.15
2.20
2.20
2.20
2.25
2.25
2.25
2.30
2.30
2.30
2.35
2.35
2.45
2.40
2.40
2.40
2.40
2.45
2.45
2.55
2.45

2.20
2.40
2.50
2.65
2.75
2.85
2.90
2.95
3.05
3.15
3.20
3.25
3.35
3.35
3.45
3.50
3.55
3.60
3.65
3.70
3.75
3.80
3.85
3.90
3.95
3.95
4.00
4.05
4.10
4.15
4.15
4.20
4.25
4.30
4.35
4.35
4.40
4.45
4.45
4.50
4.55
4.55
4.60
4.65
4.65
4.70
4.65
4.70
4.75
4.80
4.85
4.85
4.90
4.85
4.95

VOLUMEN ASUMIDO

5.00 M3
ALTURA

LADO

1.25

2.00