LABORATORIO N 4 PRESION DE VAPOR

Fecha:
REALIZACION:

Jueves, 14 de

Grupo: D Turno: 13.00 16:00 hrs.

Junio de 2012
ENTREGA:

Jueves, 21 de

Junio de 2012

Practica Integrantes Profesor

N 4 : Presin de Vapor Salazar Escobedo, Roberto 11170091 (Responsable) Alva Carbajal, Christopher 11170094 Quim. Aldo J. Guzmn Duxtan

Ciudad Universitaria

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

2012

TABLA DE CONTENIDO 1. RESUMEN ....................................................................................... 2 2. INTRODUCCION ............................................................................. 3 3. PRINCIPIOS TEORICOS ................................................................ 4 4. PROCEDIMIENTO EXPERIMENTAL .......................................... 9 5. TABULACION DE DATOS ........................................................ 10 6. EJEMPLOS DE CALCULOS ..................................................... 16 7. ANALISIS Y DISCUSION DE RESULTADOS ........................... 20 8. CONCLUSIONES ....................................................................... 20 9. RECOMENDACIONES .............................................................. 21 10. BIBLIOGRAFIA .......................................................................... 21 11. APENDICE ................................................................................. 22

Pgina | 1

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

1. Resumen
Un cuerpo necesita absorber o desprender una cantidad de energa determinada para pasar de un estado fsico a otro. Al calor necesario para pasar del estado lquido al gaseoso se le denomina calor latente de vaporizacin. Ahora si tenemos en cuenta la termodinmica clsica, parece lgico pensar que cuanto menor sea la presin a la que se le est sometiendo al lquido, ms fcil le ser a ste cambiar a estado gaseoso. Esto puede sustentarse en que los cuerpos aborrecen el vaco y de manera natural tienden a repartirse en l. As pues, el objetivo principal de nuestra prctica sern el estudio de la variacin de la presin con la temperatura en el equilibrio de agua hirviendo y vapor; las condiciones ambientales en dicha prctica fueron las siguientes: presin atmosfrica de 756mmHg, temperatura de 23C y un porcentaje de humedad de 92%. Adems, determinaremos el calor de vaporizacin del agua a partir de la medida de su presin de vapor a distintas temperaturas, concretamente entre 80 y 100 C, y se compararn los resultados obtenidos con los valores tericos. Utilizamos la ecuacin de Clausius Clapeyron para expresar matemticamente la variacin de la presin del vapor con la temperatura, y as mismo se graficaron nuestros datos y obtuvimos un porcentaje de error de 4% con respecto al calor molar de vaporizacin en la primera experiencia y de 5% en la segunda.

Pgina | 2

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

2. Introduccin
El experimento realizado tiene como objetivo determinar la presin de vapor de los lquidos mediante el mtodo esttico, a temperaturas mayores que la ambiental y con ellas calcular el calor molar de vaporizacin. Esta informacin es muy importante para la industria ya que encuentra su aplicacin en diversos procesos uno de los cuales es la caldera; que desde pequeas instalaciones locales para la produccin de vapor para coccin de alimentos, planchado en serie de ropa, tratamientos spticos de instrumentales y labores similares, con vapor de relativa baja temperatura y presin, hasta enormes instalaciones industriales, utilizadas para la alimentacin de turbinas de generacin de electricidad, y otros procesos industriales donde se requiere vapor en grandes cantidades, a altsimas temperaturas y presiones. Un ejemplo muy comn de una caldera es la olla a presin. En esencia una caldera es un recipiente cerrado, lleno parcialmente de agua a la que se le aplica calor procedente de alguna fuente, para hacerla hervir y producir vapores. Como estos vapores estn confinados a un espacio cerrado, se incrementar la presin interior y con ello la temperatura de ebullicin del agua, pudindose alcanzar finalmente muy elevados valores de presin y temperatura. Estos vapores se concentran en la parte superior del recipiente inicialmente vaco, conocido como domo, de donde se extrae va conductos para ser utilizado en el proceso en cuestin.

Pgina | 3

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

3. Marco Terico
Presin de Vapor: Las molculas en los lquidos no se encuentran en las posiciones rgidas de una red. Aun cuando carecen de la libertad total de las molculas gaseosas, ellas estn en constante movimiento. Debido a que los lquidos son ms densos que los gases, el promedio de colisiones entre las molculas es mucho mayor en la fase liquida que en la fase gaseosa. A cualquier temperatura dada, cierto nmero de molculas en un lquido tiene la suficiente energa cintica para escapar desde la superficie. A este proceso se llama evaporacin o vaporizacin. Cuando un lquido se evapora en un espacio de dimensiones limitadas, pronto las molculas del vapor se encuentran en todos los sitios del espacio libre. Pero, desde que la vaporizacin prosigue, aumentar el nmero de molculas en estado gaseoso, lo cual originar un aumento creciente en el vapor o sea mejor dicho en la presin ejercida por el vapor. A cada temperatura se alcanzar evidentemente una condicin de equilibrio cuando el nmero de molculas que abandonan el lquido para pasar al espacio sobre l es igual al nmero de las que vuelven en un tiempo dado. El espacio sobre el lquido estar saturado con el vapor y la presin ejercida ser la presin de vapor ser la presin del lquido a la temperatura dada. Se puede decir que esta presin debe ser independiente de la cantidad de lquido o del espacio ocupado por el vapor el nmero de molculas que abandonan el lquido a una temperatura dada ser proporcional al rea de la superficie proporcional a esta rea y a la presin de vapor, por lo tanto el equilibrio entre lquido y su vapor depende nicamente de la temperatura. Sabemos que en los lquidos y en los gases existen molculas energetizadas tan fuertemente que se mueven a velocidades bastante altas, cuando una de estas molculas llega a la superficie de un lquido (con la tendencia a alejarse del cuerpo principal del lquido), la molcula posee energa suficiente para deshacerse de las fuerzas que quieren retenerla en la superficie del lquido y como consecuencia se aleja de la superficie.

Pgina | 4

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

Este fenmeno de desprendimiento de las molculas fuertemente energizadas tiene lugar en toda la superficie liquida. De aqu resulta que la materia de un lquido continuamente tiende a asumir el estado de gas o vapor, a esto llamamos evaporacin. Un lquido al evaporarse origina muchas molculas en estado gaseoso, esto produce un incremento en la presin, ejercida por el vapor. De aqu de deducimos que al aumentar la temperatura (el lquido empezara a evaporarse) la presin tambin es mayor, por lo tanto son directamente proporcionales. Pero a qu se debe exactamente la presin de vapor, se da por el choque continuo entre molculas contra la superficie de las paredes que limitan al vapor es as que cuando impactan contra la superficie del lquido estarn bajo la influencia de las fuerzas atractivas de numerosas molculas liquidas que la detendrn y la integraran nuevamente al lquido, este fenmeno se conoce como condensacin.

Punto de Ebullicin: Se define punto de ebullicin de un lquido como la temperatura a la cual la presin del vapor es igual a la presin externa. Cuando se aplica calor a un lquido, su presin de vapor aumenta hasta hacerse igual a la presin atmosfrica. El punto de ebullicin vara con la presin externa que existe por encima de la superficie del lquido. Al descender la presin, el punto de ebullicin disminuye; un aumento en la presin aumenta el punto de ebullicin.

Variacin de la Presin de Vapor con la Temperatura: La presin de vapor de un lquido puro es la presin a la cual el lquido est en equilibrio con su vapor. Este equilibrio es dinmico; as, el nmero de molculas de lquido que se evaporan es igual al nmero de molculas de vapor que se condensan. La presin de vapor aumenta cuando aumenta la temperatura hasta llegar a la temperatura crtica (Tcrit), temperatura a partir de la cual no existe lquido y slo existe la fase vapor. El punto de ebullicin normal de un lquido (Teb) es la temperatura a la cual el lquido tiene una presin de vapor igual a la presin atmosfrica. La ecuacin de Clapeyron relaciona la presin de vapor con la temperatura:

Pgina | 5

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

(1) en donde representa el volumen molar del vapor y el volumen molar del lquido. Asimismo, y representan las entropas molares del vapor y el lquido, respectivamente. Debido a que el proceso de vaporizacin es reversible, podemos escribir para el cambio de entropa . (2) Donde es el calor molar de vaporizacin; por lo tanto: (3) Esta ecuacin (ecuacin de Clapleyron), es completamente general. En el caso particular de una transicin lquido-vapor en la que >> y, suponiendo que el vapor se comporta aproximadamente como un gas ideal:

Por lo que la ecuacin de Clapleyron, en este caso, se convierte en: (4) que es la ecuacin de Clausius-Clapeyron, que nos da la variacin de la presin de vapor con la temperatura. Reordenando se obtiene: (5) Y haciendo la aproximacin de que Hv es independiente de la temperatura, la ecuacin anterior se puede integrar, resultando: (6) donde P es la presin de vapor del lquido problema. Al representar grficamente frente a 1/T se debe obtener una lnea recta cuya pendiente es igual a:

Con lo que a partir de medidas de presin de vapor de un lquido a diferentes temperaturas se puede determinar su entalpa de vaporizacin.

Pgina | 6

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

Calor Latente de Vaporizacion: Para pasar de la fase lquida a la fase de vapor se necesita una absorcin de energa por parte de las molculas lquidas, ya que la energa total de stas es menor que la de las molculas gaseosas. En el caso contrario, en la condensacin, se produce un desprendimiento energtico en forma de calor. El calor absorbido por un lquido para pasar a vapor sin variar su temperatura se denomina calor de vaporizacin. Se suele denominar calor latente de vaporizacin cuando nos referimos a un mol. El calor molar de vaporizacin se podra referir a un proceso termodinmico a volumen constante o a presin constante, y los designaremos por (Hv)v y (Hv)p. En el primer proceso, el intercambio calrico que entra en juego se invierte en vencer la fuerza de atraccin del lquido y se suele denominar calor latente interno de vaporizacin molar. En el proceso a presin constante, que se realiza en la prctica frente a una presin exterior, prcticamente, invariable hay que agregar a la energa interna la necesaria para verificar el cambio de volumen, y viene dado por P(VV-VL) siendo P la presin del vapor y VV y VL, los volmenes molares del vapor y del lquido, respectivamente. As pues, el calor molar de vaporizacin a presin constante vendr dado por: (1) Como >> podemos considerar VL = 0 y (Hv)p = (Hv)v + PVV, pero como PVV = RT y considerando que se cumple la ley de los gases perfectos, nos queda: (2) Hasta ahora hemos considerado una nica presin sobre el lquido, la del vapor, pero si el lquido est sometido a una presin externa adicional la presin de vapor variar.

Entalpia: La mayora de los procesos fsicos y qumicos tienen lugar a presin constante y no a volumen constante. Esto es cierto, por ejemplo en el proceso de vaporizacin, la Pgina | 7

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

energa interna E se puede usar efectivamente en procesos a volumen constante, encontraremos muy conveniente en los cambios a presin constante emplear otra funcin termodinmica. Al igual que la energa interna no podemos establecer el valor absoluto de la entalpa para un cierto sistema aunque al igual que con E, es la magnitud delta, la diferencia de valores D H, la que es importante al igual que la energa interna, la entalpa de un sistema depende exclusivamente de su estado y no de su historia anterior.

Equilibrio Liquido-Vapor y Solido-Vapor: En estos dos casos el V molar del gas es mucho mayor que el del lquido o que el del slido por lo que puede hacerse la aproximacin:

Si adems se hace la suposicin de que el gas se comporta como gas ideal, la ecuacin de Clapeyron se transforma en: Esta ecuacin se suele expresar como:

Llamada ecuacion de Clausius Clapeyron. Si el rango de temperatura analizado es pequeo, se puede suponer que H es constante a lo largo de la lnea de equilibrio, y por tanto: Luego la ecuacion de Clausius integrada es: ( )

Pgina | 8

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

4. Procedimiento Experimental
Mtodo Esttico

En primer lugar instalamos el equipo, revisamos y verificamos el equipo instalado. Luego llenamos el matraz con agua destilada 1/3 de su volumen total, manteniendo la llave abierta al ambiente y calentamos el agua hasta el punto de ebullicin (la temperatura no debe exceder de 100C). A partir de 99Canotamos las temperaturas y presiones manomtricas hasta llegar a 80C. Tomamos las lecturas con intervalos de 1C.

Pgina | 9

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

5. Tabulacin de datos y resultados experimentales


Tabla #1: Condiciones del laboratorio Presin 756 mmHg Temperatura 23 C Humedad 92 %

Tabla #2: Datos Experimentales 2.1 Primera experiencia.


T C 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 T K 373.15 372.15 371.15 370.15 369.15 368.15 367.15 366.15 365.15 364.15 363.15 362.15 361.15 360.15 359.15 358.15 357.15 T-1 0.0026799 0.0026871 0.0026943 0.0027016 0.0027089 0.0027163 0.0027237 0.0027311 0.0027386 0.0027461 0.0027537 0.0027613 0.0027689 0.0027766 0.0027844 0.0027921 0.0027999 Patm 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 Pman 0 20 53 76 99 120 139 166 187 205 222 240 262 281 296 316 330 Pvapor de
agua

Ln P 6.628041 6.601230 6.555357 6.522093 6.487684 6.455199 6.424869 6.380123 6.343880 6.311735 6.280396 6.246107 6.202536 6.163315 6.131226 6.086775 6.054439 7,398.04 12,589.97 9,080.31 9,342.17 8,772.32 8,145.77 11,952.52 9,628.12 8,493.20 8,234.72 8,960.42 11,323.33 10,136.42 8,247.15 11,361.29 8,218.48 7,221.76

756 736 703 680 657 636 617 590 569 551 534 516 494 475 460 440 426

Pgina | 10

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor


756 756 756 756 342 359 374 389 414 397 382 367 6.025866 5.983936 5.945421 5.905362 10,538.15 9,625.75 9,955.01 11,014.94

83 82 81 80

356.15 355.15 354.15 353.15

0.0028078 0.0028157 0.0028237 0.0028317

2.2 Segunda experiencia:


T C 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 T K 373.15 372.15 371.15 370.15 369.15 368.15 367.15 366.15 365.15 364.15 363.15 362.15 361.15 360.15 359.15 358.15 357.15 356.15 355.15 T-1 0.0026799 0.0026871 0.0026943 0.0027016 0.0027089 0.0027163 0.0027237 0.0027311 0.0027386 0.0027461 0.0027537 0.0027613 0.0027689 0.0027766 0.0027844 0.0027921 0.0027999 0.0028078 0.0028157 Patm 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 756 Pman 0 19 52 76 95 117 136 161 187 206 219 238 260 278 296 314 328 340 357 Pvapor de agua 756 737 704 680 661 639 620 595 569 550 537 518 496 478 460 442 428 416 399 Ln P 6.628041 6.602588 6.556778 6.522093 6.493754 6.459904 6.429719 6.388561 6.343880 6.309918 6.285998 6.249975 6.206576 6.169611 6.131226 6.091310 6.059123 6.030685 5.988961 7,023.39 12,572.49 9,468.34 7,694.18 9,140.63 8,106.94 10,993.99 11,870.00 8,973.15 6,285.34 9,413.49 11,278.64 9,553.49 9,865.30 10,202.16 8,180.69 7,187.53 10,486.41 10,881.62

Pgina | 11

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor


756 756 374 385 382 371 5.945421 5.916202 7,261.11 11,590.58

81 80

354.15 353.15

0.0028237 0.0028317

Tabla #3: Datos Tericos


T C 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 T K 373.15 372.15 371.15 370.15 369.15 368.15 367.15 366.15 365.15 364.15 363.15 362.15 361.15 360.15 359.15 358.15 357.15 356.15 355.15 354.15 353.15 T-1 0.0026799 0.0026871 0.0026943 0.0027016 0.0027089 0.0027163 0.0027237 0.0027311 0.0027386 0.0027461 0.0027537 0.0027613 0.0027689 0.0027766 0.0027844 0.0027921 0.0027999 0.0028078 0.0028157 0.0028237 0.0028317 Pvapor de agua 760 733.24 707.27 682.07 657.62 633.9 610.9 588.6 566.99 546.05 525.76 506.1 487.1 468.7 450.9 433.62 416.8 400.6 384.9 369.7 355.11 Ln P 6.633318 9,890.82 6.597473 9,896.87 6.561412 9,903.64 6.525132 9,911.31 6.488627 9,920.14 6.451891 9,925.99 6.414933 9,933.11 6.377747 9,937.10 6.340342 9,942.52 6.302711 9,949.71 6.264845 9,959.05 6.226734 9,944.29 6.188469 9,951.84 6.149963 9,950.90 6.111246 9,987.57 6.072169 10,055.24 6.032606 10,019.56 5.992963 10,048.10 5.952984 10,069.61 5.912692 10,006.08 5.872428 10,018.98

Pgina | 12

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

Promedio Constante universal (R) Tabla #4: Clculos y resultados 4.1 Determinacin de los Promedio de
9,535.23

9962.97 1.987 cal/Kmol

promedios Promedio de
9,429.97

4.2 Grficos (en el apndice) de la primera experiencia 4.2.1 Grafico en Excel Del grafico en Excel obtenemos la ecuacin: y = -4767.6x + 19.405 Determinacin de Tenemos: Donde: m es la pendiente R es la constante universal segn el grafico en Excel:

Usamos los siguientes datos:

Reemplazando: 9,473.22

Pgina | 13

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

4.3 Grficos de la segunda experiencia 4.3.1 Grafico en Excel Del grafico en Excel obtenemos la ecuacin:

y = -4739.4x + 19.331
Determinacin de Tenemos: Donde: m es la pendiente R es la constante universal segn el grafico en Excel:

Usamos los siguientes datos:

Reemplazando: ( )

Pgina | 14

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

Tabla #5: Errores porcentuales

5.1 Primera Experiencia Experimental Promedio Grafico Excel Grafico a mano


9,535.23

Terico 9962.97 9962.97 9962.97

Error Porcentual 4.29 % 4.92 %

9,473.22

5.2 Segunda Experiencia Experimental Promedio Grafico Excel Grafico a mano


9,429.97

Terico 9962.97 9962.97 9962.97

Error Porcentual 5.35 % 5.48 %

Pgina | 15

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

6. Clculos
1 Con los datos de presin de vapor y temperatura, construya una grafica de 1/t vs Log P.

Experiencia #1:
6.70 6.60 6.50 6.40 6.30 6.20 6.10 6.00 5.90 5.80 0.00266 0.00268 0.00270 0.00272 0.00274 0.00276 0.00278 0.00280 0.00282 0.00284 0.00286

y = -4767.6x + 19.405 R = 0.9997

Experiencia #2:

Pgina | 16

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

6.70 6.60 6.50 6.40 6.30 6.20 6.10 6.00 5.90 5.80 0.00266 0.00268 0.00270 0.00272 0.00274 0.00276 0.00278 0.00280 0.00282 0.00284 0.00286

y = -4739.4x + 19.331 R = 0.9996

2 Calcule el calor molar de vaporizacin de la muestra, empleando la Ec. de Clausius-Claperyon y los datos de la grafica. Primera Ecuacin de Clausius-Clapeyron:

( Integrando se tiene:

Segunda ecuacin de Clausius-Clapeyron:

Con lo cual tenemos: ( ) ( ) (1)

Pgina | 17

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor de la experiencia 1 con los datos del grafico: ( 7,398.04 : )

Usamos la ecuacin (1) para hallar el ( )

As sucesivamente con los datos del grafico, luego obtenemos el = 9,535.23

Usamos la ecuacin (1) para hallar el ( )

de la experiencia 2 con los datos del grafico: ( 7,023.39 : )

As sucesivamente con los datos del grafico, luego obtenemos el = 9,429.97

3 Establezca una expresin matemtica de variacin de la presin de vapor con la temperatura. Compararemos la Ec. de Clausius-Claperyon con una ecuacin lineal:

Donde:

Pgina | 18

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

Ahora reemplazando datos para la experiencia 1: ( )

Usamos el primer dato de la grafica:

- 0.5126

Sucesivamente calculamos con los dems datos del grafico para hallar el - 0.4704 Con lo cual obtenemos la expresin matemtica: ( )

A continuacin hacemos lo mismo para la experiencia 2: ( ) Usamos el primer dato de la grafica:

- 0.51261

Sucesivamente calculamos con los dems datos del grafico para hallar el 0.47068 Con lo cual obtenemos la expresin matemtica:

Pgina | 19

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

( )

7. Anlisis y discusin de resultados


En este laboratorio se obtuvo un error del 4% con respecto al calor molar de vaporizacin para la experiencia 1 y del 5% para la experiencia 2. Esto se debe a los siguientes factores: Para este laboratorio el error con el que posiblemente nos hayamos topado sera que al momento de medir las distancias estas no hayan sido precisas ya que conforme vaya bajando la temperatura se debe de inmediatamente apuntar la medida en la que se encuentra. Otro error es que posiblemente no se haya equilibrado rigurosamente antes de comenzar a dictar las alturas ya que ambas columnas deben de comenzar en el mismo punto. Es as que para mejores resultados se debe de tener ms precisin en todas las mediciones que se haga ya que cada una es importante para cada paso que a continuacin se haga. De no ser as se podra llegar a un porcentaje de error muy grande el cual ya no sera aceptable.

Pgina | 20

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

8. Conclusiones
El objetivo principal de esta prctica ha consistido en estudiar la variacin de la temperatura de ebullicin del agua con la presin a la cual se est sometiendo el lquido. Inicialmente hemos calentado el agua hasta que se ha puesto a hervir. Para que se pusiera a hervir hemos necesitado que el dispositivo alcanzara la temperatura de 100 C. A continuacin hemos abierto una llave para que entrara cierta cantidad de vapor y aumentar de este modo la presin manomtrica. Luego de hacer los clculos se puede comprobar que conforme iba disminuyendo la temperatura a la cual se somete el lquido, ms aumentaba presin manomtrica pero disminua la presin del vapor. La temperatura que debe alcanzar el lquido y la presin del sistema guardan entre s una relacin que se puede linealizar para comprobar la proporcionalidad.

9. Recomendaciones
Tenemos que tener en cuenta que al momento de marcar las alturas en el papel milimetrado al variar el manmetro debemos hacerlo de la manera ms rpida posible ya que la temperatura sigue bajando. Con respecto al termmetro debemos considerar que no puede estar calibrado por lo tanto no podemos guiarnos de que el punto de ebullicin se alcanzara a los 100 C por lo que debemos examinar el agua y percatarnos exactamente cuando comienza a evaporarse. Adems al momento de retirar el papel milimetrado y comenzar a medir las diferencias de alturas debemos hacerlo con una regla milimetrada ya que el papel podra no estar calibrado. Por ltimo para disminuir nuestro rango de error debemos repetir la experiencia varias veces.

10.

Bibliografa

Chang, Raymond. Qumica 6ta edicin, pp. 204-213 Pgina | 21

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

CASTELLAN, Gilbert W. Fisicoqumica, segunda edicin. Mxico: Fondo Educativo Interamericano S.A., 1974. Pg. 785. DILLARD, Clyde y GOLDBERG, David. Qumica: reacciones, estructuras, propiedades. Mxico: Fondo Educativo Interamericano S.A., 1977. Pg. 414-415. http://academic.uprm.edu/ccsde/QuimicaFisica/Presion%20de%20vapor%20de%2 0un%20liquido%20puro.pdf http://slbn.files.wordpress.com/2008/09/tabla_presion-de-vapor.pdf http://mural.uv.es/ferhue/2o/labter/Curva_equilibrio_liquido-vapor_FHG.pdf

11.
A. Cuestionario

Apndice

1. Analice la relacin entre los valores del calor molar de vaporizacin y la naturaleza de las sustancias. A un lquido puede suministrrsele calor para aumentar su temperatura, el calor especfico de una sustancia es la cantidad de calor que se requiere para aumentar en 1 grado centgrado (o 1 kelvin) la temperatura de 1 gramo, sin que cambie su estado fsico (calor especfico = cal/gramo C, o bien joule/gramo C). La capacidad calorfica molar (kcal/mol C, o bien kJ/mol C) de un lquido es la cantidad de calor que debe suministrarse a un mol del mismo para que su temperatura aumente un grado Celsius. Si al lquido se le aporta calor a velocidad constante, la temperatura aumentar en forma constante hasta alcanzar su punto de ebullicin. Al llegar a l, permanecer constante hasta que se haya suministrado suficiente calor para que hierva todo el lquido. El CALOR MOLAR DE VAPORIZACIN .- de un lquido es el nmero de kilocaloras o kilo

joule de calor que debe suministrarse a un mol de dicho lquido en su punto de ebullicin para convertirlo en vapor, sin cambios en la temperatura. Los calores de vaporizacin pueden expresarse tambin en caloras por gramo o joules por gramo. El calor de vaporizacin del

Pgina | 22

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

agua es 540 cal/g, que corresponde a 9,73 kcal/mol o 40,7 kJ/mol. Es por ello que se debe de tener en claro que el calor molar de vaporizacin va ligado de la naturaleza de las sustancias prueba de ello son las quemaduras causadas por vapor de agua a 100 C son ms peligrosas que las causadas por agua lquida a 100 C, porque la cantidad de calor que comunican es mayor debido a la condensacin del vapor.

2.

Analice el efecto de la presin externa sobre el punto de ebullicin de una sustancia.

Aunque el agua hierve a 100C, cuando la presin es de 760 mmHg, el punto de ebullicin vara cuando la presin cambia. Por ejemplo: a bajas presiones, el agua hierve a una temperatura que es inferior a 100C. En la cumbre del Monte Blanco, a unos 4800 msnm, donde la presin atmosfrica media es de 420 mmHg, el agua hierve a poco ms de 84C. A presiones superiores a lo normal, el agua hierve a ms de 100C, por ejemplo: en las calderas de vapor a alta presin en que la presin de vapor es de 11.689 mmHg. 15.9 Kg/cm2, el agua hierve a 200C.

3. Explique el mtodo de saturacin gaseosa para determinar la presin de vapor de los lquidos. Se enva una corriente de gas portador inerte sobre la sustancia para que aqul se sature de vapor de sta. La medida de la cantidad de sustancia transportada por un volumen conocido de gas portador puede realizarse o bien mediante su recogida en un sifn adecuado o bien mediante una tcnica analtica acoplada. As se puede calcular despus la presin de vapor a una temperatura dada. Intervalo recomendado: de 10 -4 hasta 1 Pa. Este mtodo puede utilizarse tambin en el intervalo de 1 a 10 Pa siempre que se tenga cuidado. Aparato: El aparato utilizado en el presente mtodo se compone tpicamente de cierto nmero de elementos que se representan y se describen a continuacin. Gas inerte: El gas de arrastre no debe reaccionar qumicamente con la sustancia problema. El nitrgeno sirve en la mayora de los casos pero, a veces, pueden ser necesarios otros gases. El gas elegido debe estar seco. Control de flujo gaseoso: El sistema de control adecuado de gases es indispensable para lograr un flujo constante y determinado a travs de la columna de saturacin. Colectores de vapor: Su eleccin depende de las caractersticas de la muestra, as como el mtodo de anlisis utilizado. El vapor debe recogerse cuantitativamente y de manera que permita el anlisis posterior. Con determinadas sustancias, se utilizarn colectores con lquidos como el hexano o el etilenglicol. Con otras, se podrn utilizar absorbentes lquidos. Como alternativa a la recogida de vapor y su anlisis posterior, pueden utilizarse tcnicas analticas incorporadas en serie, como la cromatografa, para determinar la cantidad de material

Pgina | 23

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

arrastrado por una cantidad conocida de gas de arrastre. Adems, puede medirse la prdida de masa de la muestra. Intercambiador de calor: Para determinaciones a diferentes temperaturas, quiz sea necesario incluir en el aparato un intercambiador de calor. Columna de saturacin: La sustancia problema se deposita a partir de una solucin sobre un soporte inerte, que se introduce una vez recubierto en la columna de saturacin. Las dimensiones de sta y la velocidad de la salida deben elegirse de forma que garanticen la saturacin completa del gas de arrastre. En las determinaciones efectuadas a temperaturas superiores a la del ambiente, se debe calentar el espacio entre la columna y los colectores para impedir la condensacin de la sustancia. Con el fin de disminuir el arrastre de masa debido a la difusin, puede colocarse un capilar tras la columna de saturacin.

B. Grficos Experiencia #1: Grafico 4.2.1:

Pgina | 24

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

6.70

6.60

6.50

6.40

y = -4767.6x + 19.405 R = 0.9997

6.30

6.20

6.10

6.00

5.90

5.80 0.00266 0.00268 0.00270 0.00272 0.00274 0.00276 0.00278 0.00280 0.00282 0.00284 0.00286

El

promedio es la lnea secante a la grafica que contiene los diferentes

valores experimentales del calor de vaporizacin.

Pgina | 25

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

12,800.00 12,600.00 12,400.00 12,200.00 12,000.00 11,800.00 11,600.00 11,400.00 11,200.00 11,000.00 10,800.00 10,600.00 Calor de vaporizacion 10,400.00 10,200.00 10,000.00 9,800.00 9,600.00 9,400.00 9,200.00 9,000.00 8,800.00 8,600.00 8,400.00 8,200.00 8,000.00 7,800.00 7,600.00 7,400.00 7,200.00 7,000.00 0 5 10 15 Datos 20 25 Calor de vaporizacion promedio Calor de vaporizacion

Experiencia #2: Grafico 4.3.1:

Pgina | 26

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

6.70

6.60

6.50

y = -4739.4x + 19.331 R = 0.9996


6.40

6.30

6.20

6.10

6.00

5.90

5.80 0.00266 0.00268 0.00270 0.00272 0.00274 0.00276 0.00278 0.00280 0.00282 0.00284 0.00286

El

promedio es la lnea secante a la grafica que contiene los diferentes

valores experimentales del calor de vaporizacin. Pgina | 27

UNMSM

FACULTAD DE INGENIERIA INDUSTRIAL Presin de vapor

13,000.00

12,500.00

12,000.00

11,500.00

11,000.00

10,500.00 Calor de vaporizacion

10,000.00

9,500.00

Calor de vaporizacion Calor de vaporizacion promedio

9,000.00

8,500.00

8,000.00

7,500.00

7,000.00

6,500.00

6,000.00 0 5 10 Datos 15 20 25

Pgina | 28