You are on page 1of 2

Ecoson 950V

Veterinary Ultrasound Scanner

12 high resolution LCD with slim shape Two probe holders, 1 coupling gel holder Special probes for veterinary Probes: 2.510.0 MHz, convex/linear Zoom: partial zoom and picture in picture display Connection of video printer, laser printer and external LCD monitor Extensive application in veterinary Reports for examination of sheep, swine, bovine, equine, cat and other Various measurements: distance, area/perimeter, volume (ellipse method), heart rate, time, EF slope, fetal age, weight and EDCB - 4 USB ports, 1 VGA, 1 RS232

Specications Veterinary Ultrasound Scanner Ecoson 950V

General characteristics
Product type Probes available ultrasound scanner convex probe 2.5/3.0/3.5/4.0/5.0MHz micro convex probe 5.0/6.5/8.0MHz micro convex Probe 2.5/3.5/5.0MHz linear probe 5.0/6.5/7.5MHz linear probe 5.0/7.5/9.0/10.0MHz

Display characteristics
Display Display type Display modes Frame rate 12.1 LCD, 256 scales of grey B, B/B, 4B, B/M, M 60 frames per second (depending on frequency and probes)

Image characteristics
Digital scanning converter Zoom Dynamic range Focusing mode 576x460x8 bit At most 21 levels depth adjusting, 4 levels for acoustic zoom and PIP (Picture in Picture) 30 100dB Acoustic lens focusing, beam multi-point focusing, receiving point-to-point focus.

Image processing
Body marks General measurements Dog measurements Cat measurements Sheep measurements Swine measurements Bovine measurements Equine measurements Llama measurements General animal measurements (Animal1/Animal2) Additional data input 100 types of body marks with arrowhead indication distance, area/perimeter, volume, angle, heart rate, Time, EF slope, hip joint obstetrics GSD, CRL, HD, BD, User1~3. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics HD, BD, User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics CRL, User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics HL, SL, User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics CRL, BBD, BTD, BUD, User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics GSD, ERD, ESD, EED, User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics BPD, User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve obstetrics User1~6. cardiology left ventricle, left atrium, mitral valve, pulmonary valve

date, week, time, patient name, doctor name, hospital name, probe frequency, depth, scanning angle, focus position, frame rate, gain, acoustic output, frame average, line average, edge enhancement, dynamic range, gamma correction, gender, body mark, arrow, TGC curve, gray scale, system hint information, character note, input language, and data of measurement and calculation etc.

Power characteristics
Power supply Power input Continuous operation period AC 100240 V, 60/50 Hz 80 VA more than 8 hours

Weight and dimension


Size and weight
Rev 1.1/03.2012 EN

440 (height) x 420 (width) x 355 (depth) mm, 6.5 Kg

WEST MEDICA Franz-Siegel-Gasse 1 2380 Perchtoldsdorf, Austria tel.: +43 (1) 804 81 84 fax: +43 (1) 804 81 85 vienna@westmedica.com

www.ecoson.at www.westmedica.com