You are on page 1of 7

660MW vs 500MW

PARAMETERS

DESCRIPTION

UNIT

660 MW AT BMCR

5000 MW AT BMCR

S/H STEAM FLOW


SH STEAM PR

T/HR
KG/CM2
0C

2225
256 540 1742 299

1625
178 540 1397.4 340

SH STEAM TEMP RH STEAM FLOW RH STEAM TEMP INLET RH STEAM TEMP OUTLET RH STEAM PRESS OUTLET FEED WATER TEMP PR. DROP IN SH SYSTEM PR. DROP IN RH SYSTEM

T/HR
0C

540
0C

568 41.9 46.61 289.64 49.2 1.69 255 17 2.1

KG/CM2
0C

KG/CM2 KG/CM2

PHYSICAL

1. NO DRUM 2. ECONOMISER BANKS & O/L HEADER 3. TWO STAGES OF REHEATER

4. FINAL SUPER HEATER (COUNTER FLOW)


5. MAIN STEAM & HRH O/L HEADERS 6. SPIRAL WALL 7. VERTICAL BUCK STAYS

8. ELECTRO HYDRAULIC SAFETY VALVES


9. BA HOPPERS 6 NOS. 10. ESP PASSES 6 NOS. 11. AXIAL ID FANS

12. LDO & HFO SYSTEMS


13. BOILER FILLING ONLY THROUGH ECO FEED LINE 14. OXYGENATED WATER TREATMENT

MATERIALS

DESCRIPTION ECONOMISER

500 MW SA210Gr A1

660 MW SA210Gr C

WATER WALL
DRUM/SEPERATOR LTSH DIVISIONAL SH FINAL SH LTRH FINAL RH SH OUTLET HEADER RH OUTLET HEADER

SA210Gr C
SA299 SA213T11 SA213T11,22,91 SA213 T22,91 and TP347H SA213T11,22 SA213 T22,91 and TP347H SA335P22 SA335P22

SA213T22
SA302C SA213T11,23,91

SA213T11,23,91, 92 SA210GrC, SA213T12, 23 SA213T23,91, Super304H SA335P91 SA335P23, P91

PRESSURE PARTS MATERIALS :


SECTION Economizer Tubes Evaporator Tubes Superheater Tubes Spiral Vertical Primary Secondary Final Reheater Tubes Primary Final MATERIAL SA210C SA213T22 SA213T22 SA213T23, T91 SA213T12, T23, T91 SA213T23, T91, T92 SA210C, T12, T23 SA213T23, T91, SUPER304 H SA302C SH outlet RH outlet SA335P91 SA335P91 Material SA-210C Oxidation Criteria 454

SA-213T2
SA-213T12 SA-213T22 SA-213T23 SA-213T91 SA-T92 SUPER304H

482
552 593 593 649 649 760

Separators Headers