Snubber and Rigid Strut

Snubber and Rigid Strut


Whenever unplanned dynamic loads occur, the dynamic duty components have the job of protecting the piping or other components affected from any damage. Unwanted abrupt movement of the components in the system can be caused by: 1) Internal excitation ; pressure shocks from valve operation, water hammer, pipe breakage, boiler event 2) External excitation ; wind load, seismic events, aircraft impact, explosion Snubber is a device developed to protect high pressure/temperature piping system in power plants and various types of industrial plants. It functions to restrain undesirable displacement of piping system or components when it is oscillate due to seismic or other type dynamic load, while it allows their free movement during the normal operating mode. On the other hand, rigid strut sustains the dynamic load, but do not allow axial movement. However, as it has angular bearings, limited angular movement is permitted. For the dynamic duty components, the dynamic loads are grouped as follows ; Rated Load for Dynamic Duty Components Size No. 03 06 1 3 6 10 16 25 40 60 100 Rated Load (kN) 3 6 10 30 60 100 160 250 400 600 1,000

Note) Special order required for Size 40, 60 100

1.0 REAR BRACKET


1.1 Type Designation BSN 6

Size Symbol of Rear Bracket 1.2 Dimensions

Snubber and Rigid Strut


2.0 RIGID STRUT
2.1 Type Designation RS S - 06 Size Configuration(S : Short, L : Long) Symbol of Rigid Strut

Type S ; installation length adjustable at one end in field(short type, 35(mm)) Type L ; installation length adjustable at both ends in field(long type, 75(mm)) 2.2 Dimensions Type S

Type L

Snubber and Rigid Strut


3.0 SNUBBER AND SNUBBER EXTENSION 3.1 Type designation Snubber SNA - 16 - EA - 160 SNP - 16 - 1000 Total Stroke Length(mm) Assembly Type(EA, FA) Size Symbol of Hydraulic Snubber Total Stroke for Snubber(mm) 100(mm), 160(mm), 250(mm)- Standard Type 310(mm), 400(mm), 460(mm) and 510(mm) - Extra stroke ; available on request Combination of total stroke and design displacement Design displacement 50 or less 51-110 111-200 201-260 Total stroke(mm) 100 X X X 160 X X 250 X 310 Size Symbol of Snubber Extension Length(mm) Snubber Extension

: Optimum, : Usable, X : Not Usable Assembly Type for Snubber Type FA : with shortest attachment for a limited installation length Type EA : with extension attachment for a long installation length For Type EA, snubber extension will be required to enlarge the C-C dimension 3.2 Feature Fig. 3.1 show the schematic diagram and main items of the Snubber Several features are described as follows; (1) Reliable hydraulic system including precise valve mechanism assures stable and symmetrical performance in both loading directions. (2) Self-contained oil reservoir eliminates fluid leakage from sealed connections. (3) High durability of seal materials assures longer service duration without frequent maintenance work. (4) Well-engineered construction simplifies disassembling and re-assembling of the unit, assuring easier maintenance works. (5) Installable in a limited space because of a plain cylindrical contour. (6) Filled with thoroughly verified genuine hydraulic fluid. (7) Easy-to-read stroke indicator.

Snubber and Rigid Strut


Caution : Without special comments of the Customer, the snubber will be preset at the shop as follows; Preset at 25(mm) if snubber were extended during hot state, Preset at [total stroke-25](mm) if snubber were retracted during hot state.

Fig. 3.1 Schematic Diagram and Main Items Part No. 1 2 3 4 5 6 7 8 9 10 11 12 Item Name Holder Casing Cylinder Cover Cylinder Tube Rod Cover Piston Piston Rod Tie Rod Accumulator Casing Cover Travel Indicator Canvas Cover

3.3 Charteristics Minimum Spring Rate(kg/mm) per load and stroke Stroke(mm) Type SNA - 03 SNA - 06 SNA - 1 SNA - 3 SNA - 6 SNA - 10 SNA - 16 SNA - 25 100 250 450 650 1,500 3,000 5,000 7,000 8,000 160/250 150 300 450 1,000 2,000 3,000 4,500 6,500

Design Parameters Design Parameter Drag force Bleed Rate Lock-up Rate Frequency Range Pressure Capacity Temperature Radiant Limit Angular Offset Criteria 2% of the rated load, or 50(kg), whichever is greater 0.5(mm/sec) 1~ 4(mm/sec) 1~ 33(Hz) 1.5 times of the rated load -15 ~ 60() 110 (TEKOHR 200 Fluid) Max. 15
8

Perm. Cycle under rated load 20,000(cycles)

Recommended Maintenance Once every 10 years

Snubber and Rigid Strut


3.4 Dimensions Type FA

Note 1) A2 : fully contracted length

Snubber and Rigid Strut


Type EA

Note 1) Length at middle position

Snubber and Rigid Strut


Type SNP
k