You are on page 1of 5

WIND PRESSURE IN BUILDINGS by Eurocode 1 (EN 1991-1-4)

Basic wind velocity Terrain category vb = z0 = zmin = Building height Building depth h= b= 25 0 0.003 1 77.36 28 m/s m m m m 4.2 table 4.1

Roughness factor Orography factor Terrain factor Mean wind velocity Turbulence intensity Peak velocity pressure

cr(z) = 1.585 c0(z) = 1 kr = 0.156 vm(z) = 39.624 m/s Iv(z) = 0.098 qp(z) = 1.658 kN/m
2

(4.4) 4.3.1 (4.5) (4.3) (4.7) (4.8)

Relation Pressure coefficient Suction coefficient Uper zone, Press. Bottom zone, Press.

h/b = cpe,10 = cpe,10 = qp(h) = qp(b) =

2.763 0.800 -0.588 1.326 1.123 kN/m2 kN/m2

h > 2b table 7.1 table 7.1 Suction Suction -0.975 -0.825

Roughness factor Orography factor Terrain factor Mean wind velocity Turbulence intensity Peak velocity pressure

cr(b) = 1.426 c0(b) = 1 kr = 0.156 vm(b) = 35.659 Iv(b) = 0.109 qp(b) = 1.403

991-1-4)

kN/m2 kN/m2

Total Total

2.301 1.948

kN/m2 kN/m2

0 I II III IV