You are on page 1of 96

THE INSTITUTION OF CIVIL ENGINEERS

GESMM3 EXAMPLES
MARTINBARNES
tT
troMAs TELFoRD, LoN DoN, r es2
Published forthe lnstitution of Civil Engineers by Thomas Telford Services Ltd, Thomas Telford
House, l Heron Ouay, London E144JD.
Firstedition 1986
Second edition 1992
Terms used in this book include terms which are defined in the ICE Conditions of Contract and in
settlement of d isputes a rsing in the cou rse of civil eng ineerng contracts.
This g uide and the statements made or opinions expressed therein is published on the
undeistanding thatthe author is solely responsible forthe opinions expressed in t and that its
publication does not necessarily imply that such statements and or opinions are or reflect the
views or opinions of ICE Council or ICE committees.
@
The lnstitution of Civil Engineers 1992
Brtish Lbrary Catalogung in Publcation Data
Barnes, Martn
CESMM3 examples
l. T1le
624.1
ISBN:07277 16573
All rghts, including translation, reserued. Except forfar copyng, no part ofths publcation may be reproduced, stored in a
retrieval system, ortransmitted in any form or by any means electronc, mechancal, photocopyng, recording or otheMise,
without pror wrtten permission being obtained from the publsher.
Typeset by Opus Magazns, London
Prnled and bound in Great Brtain by Staples of Rochester, Kent
CONTENTS
lntroduction
Diagrams
Example billof quantities pages
3
17
Class A:
Class B:
Class C:
Class D:
Class E:
Class F:
Class G:
Class H:
Class l:
Class J:
Class K:
Class L:
General items. 19
Ground investigation, 26
Geotechnical and other specialist processes, 29
Demolition and site clearance, 31
Earthworks, 32
ln situ concrete,36
Concrete ancillaries, 39
Precast concrete, 44
Pipework-pipes, 45
Pipework-fittings and valves, 47
Pipework-manholes and pipework ancillaries, 50
Pi pework-su pports a nd protection, ancilla ries to
laying and excavation, 53
Structural metalwork, 56
Miscellaneous metalwork, 57
Timber,58
Piles, 60
Piling ancillaries, 64
Roads and pavings, 67
Rail track. 70
Tunnels. 72
Brickwork, blockwork and masonry. 75
Painting, 78
Waterproofing. 79
Miscellaneous work, 81
Sewer and water main renovaton and ancillary works, 84
Simple building works incidental to civil engineering works. 91
Class M:
Class N:
Class O:
Class P:
Class O:
Class R:
Class S:
Class T:
Class U:
Class V:
Class W:
Class X:
Class Y:
Class Z:
INTRODUCTION
INTRODUCTION
The Work Classifcation divides the work which is covered by the
CESMM into twenty-six classes lettered A to Z. Each class contains
three types of information: an 'includes and excludes' list, a
classification table and a table of rules.
The includes and excludes list is given at the head of each class. It tells
the user of CESMM3 which general types of work are included in a
class and which classes cover other similar work which is excluded
from that class. In some cases, e.g. in classes A, C, D, I and V, the
scope or coverege of the items in a class is also given. These lists should
not be regarded merely as an index to CESMM3; they are important
to the interpretation of the coverege of the bill items generated by the
classes. Clearly the lists do not set out to be comprehensive; they do
not mention everything which is included or everything which is
excluded.
The classification table is the tabulation of the work components
covered by a class, divided into the three divisions es described in
section 3. The horizontal lines in the tabulation indicate which lists of
features from one division apply to which features in the other
divisions. This is usually straightforward, but must be given close
attention where the lines ate at different levels in the different
divisions. Headings are given in some lists of features and are printed
in italics in CESMM3. They should be included in item descriptions in
all cases where they would not duplicate information. For example,
the heading 'Cement to BS 12 or BS 146'is obviously essential in the
descriptions for items F 1-3
*
1-4 covering provision of concrete as
otherwise the information about cement is not given.
In many places the classification table uses the word'stated'in phrases;
such as 'Formwork : stated surface features' and 'Width: stated
exceeding 300 mm'. Written in full these phrases mightbecome: 'This
item classification is for formwork which has a particular surface
feature. Descriptions of items in this classification shall state the
Particuler
surface feature required' and'This item classification is for
things the width of which exceeds 300 mm. Descriptions of items in
this classifcation shall state the actual width of the things required'.
The rules on the right-hand peges ere as important as the classification
tables. In one sense they are more important as sometimes they
overrule the classification table. The rules ere errenged alongside the
sections of the classification to which they apply. This is indicated by
the horizontal lines which align from the left- to the right-hand pages.
Rules printed above a double line apply to all items in a class (see
paragraph 3.11).
The terms which are printed in italics in the rules are those which are
CESMM3 EXAMPLES
taken directly from the classification table. This style of printing is
adopted as an aid to cross-reference between the tables and the rules; it
has no effct on interpretation of the rules.
CESMM3 uses some untraditional terms. They are adopted to
comply with British Standards or to keep up with the move to
standardize units and terms under the general umbrella of metrication.
Thus pipes have a bore not a diameter, because the bore is the diameter
of the hole down the middle, and cannot be confused with the outside
diameter of the pipe. Mass is the measure of the quantity of matter;
weight is no longer used. CESMM3 refers to weight in only one place
where it was considered that the alternative phrase'piece mass' would
be totally unfamiliar. The abbreviation for number is'nr'.
Example bill pages are given in this book for each class in the Work
Classification. The examples are not taken from actual contracts.
They can be used as a guide to the layout and style ofbills and bill items
compiled using CESMM3. The example bill items, not being related
to a particularjob, show less non-standard description amplifying the
basic descriptions than is given in real bills. Similarly, in order not to
imply that particular specifcation details are recommended, item
descriptions in the example bills frequently refer to hypothetical
specification clauses by a clause number or to details on hypothetical
drawings. This procedure is permitted in real bills by paragraph5.l2
but it is not adopted in them to the same extent as it has been in the
example bill pages.
The examples use the code numbers in the'Work Classification as item
numbers. This practice is recommended but is not a requirement of
CESMM3. It is adopted at the discretion of the bill compiler in
accordance with paragr aph 4.3.
The examples do not cover all the items which culd be generated by
CESMM3 or even all the items which might occur in one bill. They
give hypothetical items which demonstrate those applications of the
rules in CESMM3 which are novel or would benefit from
demonstration for other reasons. The items are laid out as ifthey were
pages from a bill to demonstrate layout, numbering and the use of
headings. The examples illustrate the alternative procedures open to
bill compilers where CESMM3 permits alternatives. Compilers of
real bills should try to be consistent, not to demonstrate all the possible
alternatives as the examples do.
Each heading and item description in the example bill pages ends with
a full stop. This is a helpful discipline when there are two or more
headings t the top of one bill page. The full stops help to relate the
headings to the lines drawn across the description column which show
which items apply to each heading (see paragraph 5.9). Within item
descriptions, a semicolon has been used to separate basic from
additional description.
2
i
I
:!t
'l
t-
Work measured in
item A
I
tt"me
I
lr
L--_J
DIAGRAMS
Original Surface and
Commencing Surface
for item A
Fig. 1. Application of the definitions
of the four surfaces given in
paragraphs 1 . 1 0-1 .1 3. The Excavated
Surface for one item becomes the
Commencing Surface for the next
item if excavation is measured in
more than one stage (see
also
paragraph 5.21)
Maximum
depth
ilem A
Surface
item A and
Commencing
Surface for item B
Maximum
deplh
item B
Final Surface and
Excavated Surface
for tem B
Commencing
Fig. 2. Three items are required for
this excavation. Al an be described
as 'maximum
depth 10- 15 m'.
Definition rules 1.12 and 1.13 do not
require intermediate surfaces to be
identified Other solt material
Other soft material
Excavated
CLASS l: PIPEWORK- PIPES
Fig. 3. Classification table for pipes in
class l. This is the simplest table in
CESMM3 and shows clearly how the
three divisions of classification
combine to produce brief
descriptions and code numbers for
groups of components of civil
engineering works. ln this case the
brief descriptions are amplified in bills
of quantities by more specific
information given in accordance with
the additional description rules in
class I
lncludes:
Excludes:
Provision, laying and
jointing
of pipes
Excavating and backfilling pipe trenches
Work included in classes J, K, L and Y
Piped building services
(included in class Z)
FIRSTDtvtStON sEcoND DrvlsloN THIRD DIVISION
l Claypipes m
2 Concretepipes m
3 lron pipes m
4 Steelpipes m
5 Polyvinylchloride pipes m
6 Glass reinforced plastic pipes m
7 Highdensitypolyethylenepipes m
8 Medium density polyethylene ppes m
1
2
3
4
5
6
7
8
Not in trenches
ln trenches, depth: not exceeding 1.5 m
1.5-2 m
?-2.5 m
2.5-3 m
3-3.5 m
3.$4m
exceeding 4 m
5
Nominal bore: not exceeding 200 mm
200-300 mm
300-600 mm
600-900 mm
900-1200 mm
1200-1500 mm
1500-1800 mm
exceedng 1800 mm
CESMM3 EXAMPLES
MEASUREMENT RULES
M1 The Commencing Surface
adopted n the preparaton ofthe
Bll of Ouanttes shall be adopted
for the measurement of the
completed work .
M2 The depths of grout holes,
holes for ground anchorages and
drainsshall be measured along
the holes irrespective of
inclination.
M3 Drilling through previously
grouted holes in the course of
stage grouting shall not be
measured. Where holes are
expressly requred to be
extended, the number of holes
shall be measured and drilling
through previously grouted holes
shall be measured as drilling
through rock or aftficial hard
material.
M4 The numberofstages
measured shall be the total
number of groutng stages
expressly required.
DEFINITION RULES COVERAGE RULES
GLASS C
ADDITIONAL
DESCRIPTION RULES
Al The diameters of holes shall
be stated in item descriptions for
drilling and drving for grout holes
and grout holes.
Fig. 4. The layout of the classified
rules in CESMM3: note the different
style of each of the four types of rule,
the horizontal alignment and the use
of the double horizontal line to
separate rules of general applicaton
to the class
Section A.
Section B.
Section C.
Section D.
Section E.
List of principal quanttes
Preamble
Daywork Schedule
Work items
Part 1. General items
Part 2. Outfall
Part 3. Plowden treatment works
Part 4. West branch sewers
Part 5. East branch sewers
Part 6. Whettleton pumpng staton
Grand Summary
Fig. 5, Example of the standardized
sequence of contents of a bill of
quantities which results from
application of paragraphs 5.2 and 5.8.
Sections of the Bill are identifled by
the letters A to E to distinguish them
from the numbered parts into which
the work items themselves are
divided
Section A. List of principal quanltes
Fig. 6. Example of a list of principal
quantities compiled to comply with
paragraph 5.3
General items
Provisional Sums
Prime Cost ltems
Outfall
Excavation
Filling
Concrete
900 mm steel pipework
Plowden treatment works
Excavation
Filling
Concrete
Pipework
West branch sewers
Pipelines
Manholes
East branch sewers
Pipelines
Manholes
Whettleton pumping station
Excavation
Filling
Concrete
Part 1 .
Pat 2.
Part 3.
Part 4.
Part 5.
Part 6.
40 000 f
165000
4 000 m3
1 000 m3
850 m3
200 m
23 000 m3
8 000 m3
9 000 m3
1 200m
8000m
40 nr
9000m
50 nr
m3
m3
m3
2:O
400
600
6
I
Dl Drilling and excavaton for
work in this class shall be deemed
lo be in materal other than rock or
a n if i cia I ha rd m aferial un less
otherwse stated n tem
descriptons.
Cl ltemsforworknthsclass
shall be deemed to include
disposal ofpxcavated material and
removal of dead services.
DIAGRAMS
E421 E422 842
nal Surface
Fig. 7. CESMM3 does not divide
excavation nto depth bands
(a),
but
according to total depth (b)
1
2
E
_
*o5
o
o
.l
0
Final
(a)
Orginal Surlace
1
2
E
.
o-
o

10
Final Surface
(b)
Numbor
Fig. 8. Column layout described in
paragraph 5.22 and typing capacity of
the columns when a typewriter
producing ten characters to the inch
sis
used
x999.99 Description line max 34 chaacters sum 999999
o.99 m2 99999.9
o
)
6
D
o
o
o
c
o
o
o
o
o
c
o
o
o

Fig. 9. Time based graph showing


how the payment of the Adjustment
Item sum relates to the tendered
value of work items. lt illustrates the
effect of paragraph 6.4
Work items (a) When the work items do not reach
their tendered value
Tme
o
l
E

o
o
E
c
o
o
100
o
ol
6
c
o
o
o
G
(b) When lhe work items exceed
their lendered value
7
8424
8425
8426
E 4 26
Amount
Item doscrpton Rato
f p
Adjustment
Ad
justment
Work items
Time Completion
CESMM3 EXAMPLES
Fig. 10. All prices against items in
bills of quantities compiled using
CESMM3 have an assumed
.relationship to cost. This relationship
is either to quantities which can be
observed in the physical work itself
(quantity-proportional
unit rates), to
time (Time-Related
Charges) or to
neither quantity nor time (Fixed
Charges). This figure shows where
the items which embody these three
relationships are to be found in
CESMM3
Related to quantites
Relationship specif ied
Fig. 1 1 . Zones of inclination for grout
hole drilling and driving given in the
second division of class C, item
codes C 1-3 1-5
*.
Notice the
precise
boundaries for the zones. For
example, drilling at 45'to the vertical
upwards is in zone 4, drilling at 45" to
the vertical upwards is in zone 5
@
@
@
@
o
Fig.12. These ridiculously shaped
structures, which are to be
constructed after excavation for them
has been carried out, demonstrate
the application of rules M6 and M16.
The volume measured for excavation
is the volume bounded by the double
line. The volume measured for
backfilling, if required, would be the
part of this volume not occupied by
the finished structure
I
t
Work items
Specf ed requremenls Method- Related Charges
Fixed
Time
related
Ouantity
related
Fixed
Time
related
.::
:' 45'
232 e.o.d.
Excavated
volume
DIAGRAMS
235 a.o.d
Fig. 13. The volume measured for
excavaton below water is that which
is below water at the higher
anticipated level
at 235 a.o.d.
Boundary at 232 a.o.d.
b
Fig. 1 4. The general
case of the cut
and fill operation. When a composite
earthmoving operation such as that
represented here is to be measured,
care must be taken to ensure that
enough quantities are measured in
the field to enable the quanttes
against the bill items to be calculated
Dispose
a
%,
,o
lmport
d
e
9
ililtililt
CESMM3 EXAMPLES
mm
B
500 600
0.1 o4 09 1.1 1 1.3 1 4 1.5
m
mm2
o
@
2500
@
10
A
Not exceeding 0.03 m2 003-0 1 m2 0 1-0'25 m2 0 25-1 m2 Exceeding 1 m2
m
0.1 o2 03 o.4 0.5 06 07 0.8 0.9 10 111 1.3 1.4 1 5
mm
Fig. 15. Nomogram for areas of
cross-section of rectangular columns,
beams, piers and casing to metal
sections. lf a straight edge s placed
from the breadth dimension on scale
B to the depth on scale D, the
intersection on scale A shows the
range from CESMM3 in which the
cross-sectonal area of the
component occurs. lf the intersection
is very close to a range boundary, it is
necessary to check by calculation
Fig. 16. lllustration of rule M2(e).
Formwork ig measured for the
surface AB but not for the surface BC
45'
i,
10
Earth or other matter
DIAGRAMS
@
t
o
o
o
@
o
+
o
q,
o
o
o
o-
@
Fig. 17. lnclination zones for plane
formwork defined in rules M2(e), M3,
D1 and 42. Note the precise
boundaries of the zones. For
example, an inclination of 10" to the
vertical is in zone 3; an inclination of
1OVz" is in zone 2
@
10'
@
5" o
3

o
x
Horzontal
o
15'
15"
5
45'
10" 10'
@
@

o
o
o-
o_
@

o
o
o
o
@
Formwork sde
@
The simple case requiring
no additional descrption
Fig. 18. lnserts classified according to
rule A1 5. The fourtypes of insert are
shown illustrating their different
effects on wall formwork. The figure
viewed on its side illustrates the
same points for slab formwork
(a) Proiecting from one
surface of lhe concrele
(b) Projecting from both
surfaces of the concrete
(c) Wholly within lhe concrete
11
CESMM3 EXAMPLES
Fig. 19. Measurement of pipe trench
depths. The depths of pipe trenches
are given in zones
(measured to pipe
invert level). Thus any variation in
trench depth at remeasurement
shows itself as a change to the
lengths of pipe which occur in each
depth zone
Commencing
Surface
Manhole A
Manhole B
Depth
15m __---
2m
-
25 m ...-
3m_
-
35 m
4m-
7
_-
-u-
--'/
l3
3,5
Fig. 20. Simplified example showing
how remeasurement of an pipe run in
depth zones deals with variations in
pipe trench depths
Ppe
Ppe
b
b
Ppe
Ppe
a lnvert raised 250 mm
lnvert lowered 250 mm
80m
Zone
2
Depth
15m
2m
25 m
3m
35 m
4m
J
4
5
6
7
o
Ppe
run
a
b
c
Fig.21 . Dimension used in
calculating nominal trench widths for
multiple bore ducts and twinned
pipes. This is described in rules D1
and D7 of class K and 43, M2 and D1
of class L. The dimension is referred
to as the
'distance between the
inside faces of the outer pipe walls'
I
tL
=.---
a
.---
4
5
Zone
2
Length in zone: m
2 3 4 5 6 7
20
20
20
10
20
20 10
10 20
20
10
20
20
20
12
Driven pile
Bored pile
DIAGRAMS
Fig.22. Measurement of piles. At
least two bill items are given for each
group of preformed concrete, timber
or isolated steel piles: number of
piles of a stated length and depth
driven. At least three bill items are
given for each group of cast in place
piles: number of piles, concreted
length and depth bored or driven
stating the depth of the deepest ple
in the group.
These items are
generated
by the third division of
classification of class P and
associated rules.
Fig. 23. Awall with these surface
features could be considered as of
thickness 900 mm with 200 mm x
200 mm projections oras of thickness
1 100 mm with 200 mm x 200 mm
rebates. Additional description must
be given when work such as this-
straddling the boundary of two parts of
the Work Classif ication
-
is to be
measured. This is the effect of
paragraph
5.13. The wall in the figure
should be identified using additional
description to avoid uncertainty
13
r -
Pile
length
Depth
bored
or driven
900 mm
length
Pe
I
-t
-l
\
\
0"
t-
1100 mm
-l
t-
CESMM3 EXAMPLES
Fig.24.lnclination zones used for
classification of
Painting
and
waterproofing of plane surfaces of
width exceedrng 1 m as given in the
third division of classes V and W.
(See
also rule M2.) Note the
Precise
boundaries of the zones. Forexample,
a soff it surface inclined at 60'to the
horizontal is classed in zone 4; one
inclined at 61" is classed in zone 3'
@
@
on V)
@
Side painted
or waterproofed
@
Fig.25. Skirting boards are measured
as a single item where theY have the
same characteristics but different
.
shapes
(rule A4). These skirting
bords have the same dimensions but
two different shaPes
I[,
14
DIAGRAMS
L Fig.26. Rule M3 simplifies the
measurement of diagonal strutting.
The length measured is 2 x L rather
thanS x /
Joist Strut
Walls
Fig.27 .lnclination zones used for
classification of boarding and
insulation (rule
D4) and surface
finishes, linings and partitions
exceeding 1m wide (rule
D7). Notethe
precise boundaries of the zones. For
example, a sloping uppersurface
inclined at 75" to the vertical is classed
inzone2; one inclined at 76o is classed
in zone 1
o
o
I
<)
o
=
Walls
xXXXXXXxxxxxX)a Side to be boarded, insulatd or finished
15
Number Item descrlptlon Unlt Gluantlty Rate Amount

P
PRT I : GRNERT, rTRMS
-
a^+r-^+ri-1 raarll rananf
Performance bond.
Insufance of the hlorks
Thlrd party lnsurance.
sum
sum
sum
sum
sum
wk
sum
sum
wk
wk
nr
sum
sum
wk
sum
sum
sum
sum
20
2ii8
20
200
20
Speci fi ecl requi rements.
Establlshment and removal of offices for
the Engineer's staff.
Maintenance of offices for the
Engineer's staff.
Maintenance of offices for the EngJ-neer's
staff after lssue of the substantlal
Completion Certlflcate.
Establishment and removal of laboratorles
for the Engineerts staff.
Maintenance of aboratories for the
Engineer's staff,
Transport vehicle; as Speclfieatlon
clause 184 .9.
Transport vehlcle; as Speciflcatlon
clause 184.9 for use after lssue of
Substantla CompJ-etIon Certiflcate.
Set of progress photographs comprisl-ng
six prints.
Equipment for use bv the Englneerts staff-
Establlshment and removal of offlce
equlpment.
Malntenance of offlce equipment.
Malntenance of offlce equlpment after lssue
of Substantlal Completlon Certlflcate.
Establishment and removal of laboratory
equlpment.
Malntenance of laboratory equipment.
Establlshment and removal- of surveylng
equipment.
Maintenance of surveying equipment.
EXAMPLE BILL OF OUANTITIES PAGES
GENERAI ITEMS
At- 10
A120
130
A211.1
Azrt.2
A211.3
ALz.Z
A2r2.2
A227.1,
A22r.2
A229
A231.1
A23r.2
A231.3
A232,L
A232,2
A233. I
A233.2
PAGE
19
CESMM3 EXAMPLES
GENERAI ITEMS
A242
A243
A250
A260.L
A260.2
A260.3
A260 .4
A260.5
A260,6
A260,'l
A2?L.L
A2'12.L
A212.2
A273.L
A2'13.2
A2't6.L
A2't3.2
A27 6.I
A27 6.2
A277.L
A2't1 .2
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
Qnal fI a ranrri rt
Attendance upon the Engineer, s staff,
chainmen.
Attendance upon the Engineer, s
laboratory assistants .
tettng of material-s; concrete
samples and methods of testlng
Speclfication clauses 186.1 to
staff,
test cubes;
as
186.9
Testing of the Works-
Clay pipes normaL bore not exceedlng
200 mm, test as Specification clause 18?.1
Clay plpes nominal bore 200 - 300 mm,
test as Speclficatlon cl-ause 187.2
Spun lron plpes nomlnal bore not exceedlng
200 mm, tesL as Speclfication clause 18?.3
Spun iron plpe nominal- bore 200 - 300 mm,
test as Speciflcation clause 187"3.
eration tanks; watertightness test as
Specificatlon clause 188. L.
FInaI settllng tanks; watertlghtness test
as Speclficatlon clause 189.1
Storm tanks; vratertlghtness est as
Speclficatlon cLause 190. 1
wk
wk
nr
sum
sum
sum
sum
sum
sum
sum
sum
sum
wk
sun
sum
sum
wk
sum
h
sum
wk
104
104
400
104
104
500
L'l
Tempora ry tlorks .
Traffic dlverslons.
Traffic regulatlon; establ-ishment and
removal.
Trafflc regulatlon; continuLng operatlon
and malntenance.
EstabLishment and removal of access roads.
Maintenance of access roads.
Establshment and removal of pumplng plant.
Malntenance of access roa.ds.
EstabLishment and removal of pumping plant.
Operatlon and malntenance of pumping plan.
Establlshment and removal of de-waterlng
pant.
Operatlon and mantenance of de-vraterlng
plant.
20
PAGE
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
Method-Rel ated Charges.
ccommodtl on and hui I dl ngs.
Set up offices; Flxed.
Malntaln offlces for the duratlon of
contruction; Tlme-Related.
Remove offlces; F1xed.
Set up stores and materials compound;
Flxed.
Remove stores and materlals compound;
Fxed.
Set up canteens and messrooms; Flxed.
Operate canteens and messrooms for the
duratlon of construction; Tlme-Related.
sum
sum
sum
sum
sum
sum
sum
sum
sufn
sum
sum
sum
sum
sum
Servl ces.
Set up electrlclty supply and standby
generator; Flxed.
llater suppJ-y for the duratlon of
constructlon; Tlme:Related.
Slte transport for the duration of
constructlon comprlslng oire 5t truck and
two tractors and trailers; Time-Related.
elfare facllltles complylng wlth IISAW
regulatlons for the duratlon of
constructlon; Tlme-ReLated.
P.Ia.oL
35t crane for erc:v:t{on nd concrctlno
of main tanks
Brlng to Slte; Flxed.
Operate; TIme-Related.
Remove; Flxed.
EXAMPLE BILL OF OUANTITIES PAGES
GENERI ITEMS
A311.1
A31 I .2
A311.3
314.1
314.2
A315.1
431 5.2
A32 1
A322
A325
A32'l
A331.1
A331 .2
A331.3
Curpldd
W
tende PAGE
21
CESMM3 EXAMPLES
GENERAI ITEMS
A333. 1
A333 .2
A33 9. 1
339.2
A351.1
A351.2
A351.3
353
A35 6
A361.1
A361.2
A352.1
A362.2
A352.3
A362.4
Conrpleted
W
tenderct
22
Number Item descrlptlon Unlt Qtnntlty Rate Amount
E p
Team comprisino two pusher/ripper
bulIdozers. six mot-or scrors and one
-^-a-la
h'rl i^-^- f nr n { n omhnlmant
shale fIII1no
Bring to Slte twlce and remove twice;
rtxd.
Operate i Tlme-Rel,ated
sum
sum
sum
sum
sum
sum
sum
sum
sum
sum
sum
sum
sum
sum
sum
Brlng to Slte and remove
Jacks
and other
prestressing plant for stessl-ng brldge 12
deck beams; Fixed.
Bring to Site and remove 3 grout pans and
2 grout pumps for vrork l-n items
2.8111.L to 2.8345 lncluslve; Flxed.
Temporrv horks
Road dl,verslon at Newton Street
drrrl ngr construct I on crr' vert 2I b.
Install-; Fixed.
Operate and maintain; Tlme-Rel-ated.
Remove; Fixed.
Install access road, Slte entrance to
batchlng plant near downstream tunneJ-
portal-; Fixed,
Pumplng as required during excavation and
concretlng of tower foundatlons;
Tlme-Re l-ated.
Erect scaffoldlng surroundlng
administration bLock; Fixed.
lllre of scaffoldlng surroundlng
admlnistratlon bLock from completlon of
frame until completion of brlckwork;
Tlme-ReLated.
Erection of falsework to support
brldge deck formwork: 'i-ed.
Bridg 1..
Brldge 2.
Bridge 3.
Brldge 4.
PAGE
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
Method-Rel ated Chrges
Tenprary lilorks,
Temporary sheet piJ.e wall- to retaln
excavatlon on South side of Long Lane
dlversion from chainaqe L25 to 275; Fixed
Make 4 sets of full height forms for
treated water reservolr columns; Fixed.
Make 120 raked slde paneJ-s and 20
rectangular end panels for formwork to 3m
high 1lfs ln maln dam concreting; F1xed.
Use L5 m long clrcular steel- form for
linlng diverslon tunneL; lime-Related.
sum
sum
sum
sum
sum
sum
sum
sum
Supervlslon and labour.
Management and supervlsion for the duratlon
of constructlon; Tlme-Related.
Addltlonal management and supervlslon
durlng constructlon of the maln pumphouse;
Time-ReIa!ed.
Adminlstralon for the duratlon of
constructlon; Time-Related.
Labour for maintenance of pJ-ant and site
services during earth moving and concreting
operations; Time-Rel-ated.
Labour for concreting gang durlng
concreting operatlons at main treatment
works site; Time-ReLated.
EXAMPLE BILL OF OUANTITIES PAGES
A363
4354.1
A364.2
4364 .3
371.1
A37r.2
^31
2
A373.1
A313.2
Cotnpletd by lenilerer
PAGE TO
23
Rate
Amount
I p
Unlt Quantlty
Item descrlptlon
Number
Percentage adJustment to
Provislonal Sum for Daywork labour.
Materials,
Percentage adjustment to
ProvlsionaL sum for Daywork materials
Plant.
Percentage adjustment to
Provislonal Sum for Daywork Plant.
SupplernentarY charges'
Percentage adjustment to
Provislonal Sum for DaYwork
supplementarY charges.
rov sl ona'l Srrms
tleyr.tork -
Labour.
Other Provl s ona Sums.
Permanent dlverslon of existing
services.
LandscaPing.
Repalrs to existing tanks.
Repairs to existing
PiPellnes'
50000
25000
2000c
20000
25000
1 5000
10000
CESMM3 EXAMPLES
GENERAL I
A4 11
A412
A4 13
A4 14
A4 15
A41 6
A4 1.?
A4 1B
a,420,t
A420.2
A420.3
A420 . S
t-
24
PAGE
Number Item descrlptlon
Unlt Ouantlly Rate Amount
I p
Nam{ n:ta{ Qrih-^^}
'-^+
< wh { h { n I rrla warl
Elect,ricaL installatlon.
Labours.
Other charges and profJ.t.
FIow recordlng and control equipment.
Labours.
Flow charges and profit.
Pumping machlnery.
Speclal laboursi a+-tendance on
commLssloning and testing as Speclflcation
clause 207.I, carrled out upon completion
of pump lnstalLatlon.
Other charges and proflt.
sum
sum
t
sum
sum
t
sum
sum
t
sum
sum
t
sum
sum
t
50000
2 5000
42000
3 7000
12000
00
00
00
00
00
It^.1
- '+ ^i
r: f c ur+ i h la na
lnelude work on the Site.
Precast concrete brldge beams.
Labours.
Other charges and proflt.
Precast concrete fltter wall units
Iabours.
Other charges and proflt.
EXAMPLE BILL OF OUANTITIES PAGES
GENERAL TEMS
A510. 1
A520. 1
A540.1
A510 . 2
A520.2
A54 0 .2
A510.3
A530
A54 0 .3
4610. 1
A620. 1
4640. 1
.61,0.2
A620.2
A640.2
PAGE
25
Rate Amount

p
Unlt Ouantlty Item descrlptlon Nurter
Number ln materlal other than rock maximum
depth 2 - 3 m; mLnlmum plan area at the
bottom of the excavation 2 m2. nr 6
Depth ln materlal other than rock;
mlnlmum plan area at the bottom of the
excavatlon 2 m2.
Depth supported.
Depth backflLled wtth excavated materlal.
Removal of obstructions.
m
m
m
h
18
18
18
5
Pumplng at a mlnimum extractlon rate of
7000 litres per hour. h T2
T.TGHT CABT.E PFIRCTISSTON BORFIHOT'F]S.
Nomtn-L-diamete r--..at*base.
-Ll0-mn.
Number.
Depth ln holes of maximum dePth not
exceeding 5 m.
Depth ln hoLes of maxlmum depth 5 - 10 m.
Depth in holes of maxlmum depth 10 - 20 m.
Depth in hoLes of maxlmum depth 20 - 30 m.
nr
m
m
m
m
I
20
10
15
50
Depth backfilled wtth excavated materlal
Chlselllng to prove rock or to pentrate
obstructlons.
95
h 10
CESMM3 EXAMPLES
B1 13
Bt-3 0
B1 50
B1 60
B170
BlBO
B2L0
823 1
8232
8233
8234
B260
8270
26
PAGE
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
ROTRY NRTT.T,ED trOREIHOI.ES.
Mlnlmrrm core d{ameter ?5 mm.
Number; continuatlons of llght cable
percusslon borehol-es.
Depth wlth core recovery In holes of
maximum depth 10 - 20 m.
Depth backfill-ed with cement grout.
Core boxes, core 3.0 m long.
SMPT,ES.
Dlsturbed samples of soft materlal from the
surface or from trla- plts and trenches:
mlnimum 5 kg;.C1ass 3.
Open tube samples from boreholes.
100 mm diameter x 450 mm long, undsturbed
sample; Class 1.
Disturbed sarnples from boreholes: mnlmum
5 kg, Class 3.
Groundwater samples from boreholes
minlmum 1 lltre.
nr
m
m
nr
nr
nr
NT
nr
nr
nr
nr
m
2
30
10
4
18
4o
2t
I
I
25
5
18
3
9
STTE TESTS ND ORSERVATTONS.
Groundhrater level; taken at commencement
and end of work each day.
Standard penetratlon test; in llght cable
percussion boreholes.
Vane test ln borehole.
TNSTRUMtrNTAT, OBSERVT ION S
Pressllr hed: week'l w ollserwat lons.
'
Standplpes.
Install covers.
Standpipe readings.
EXAMPLE BILL OF OUANTITIES PAGES
8310
834 3
B3 60
8370
841,2
B42L
8422
8423
85 L2
95 13
851 5
861 1
B613
861 4
PAGE
27
CESMM3 EXAMPLES
871 1
B7L2
B714
871 5
8722
8123
874 1
B76t
871 5
883 1
8832
883 3
B84 0
,1
Number Item dcrlptlon UnIt Quantlty Rate Amount
E p
T.AFORATORY TESTS
Csslflcatlon.
Moisture content.
Atterberg llmlts.
Particle size analysis by- sleve
Partl-cLe size analysls by plpette or
hydrometer.
nt
nr
nr
nr
nr
nr
nr
nr
h
h
h
nr
10
20
4
16
I
6
20
6
5
15
5
2
Chemicl content
SuLphate.
pH vaJ.ue.
Consolldati on.
Oedometer cell-.
en I el-ranaf h
Qulck undralned trlaxiaL set of three
38 mm dlameter speclmens.
Rock strength.
Point load tests on core samples as
Speclflcatlon cl-ause 8243
PROF'ESSTONAI. SERVTCNS.
Engineer or geologlst graduate.
Enqineer or geologist chartered.
Engineer or geologist princJ-pal or
consultant.
Vlslts to the SIte.
28
PAGE
Number Item descrlptlon Unlt Otantlty Rate Amount
E p
GROTECHNJC, Nn OTI{ER SPFCIAT,IST PROCESSES.
Dr{ Ing for grout hoes.
Ii ameter 50 rnm.
Vert lc I ll y downwards .
In holes of depth: not exceeding 5 m.
In holes of depth: 5 - 10.m.
In holes of depth: 20 - 30 m.
In holes of depth: 20 - 30 m.
In holes of depth: 50 m.
m
m
m
m
m
m
m
nr
nr
nr
t
t
t
nr
nr
t
t
t
nr
80
160
310
630
200
620
3300
234
't02
20
154
290
50
50
75
25
200
269
50
,Downwrds l- :n nc'l
p
O'
-
4 6' f n l-ha
vertlc'l .
In hol-es of maximum depth: 10 - 20 m.
In hoLes of maxlmum depth: 20 - 30 m.
Grout holes diameter 50 mm.
Number of holes.
Number of stages.
Slngle water pressure tests.
Grorrt materials and lnlection.
Materla l s.
Cement; to BS 12.
Pulverlzed fuel ash; as Speclflcatlon
clause G420.7 .
Sand; to BS 1199.
Tn jectlon
.
Number of lnJections; in descending stages
Number of lnjectlons; 1n ascendlng stages.
Neat cement grout,
Cement and sand grout.
Cement and pulverlsed fueL ash grout.
Slngle packer settLngs.
EXAMPLE BILL OF OUANTITIES PAGES
c111
CLL2
c 113
c 114
c 116
cL23
cIz4
c4t0
c420
c430
c51 1
c512
c513
c521.1
c52r.2
c522
c523.L
c523.2
c526
PGE
29
Amount
E
P
Unlt Quantlty Rate
Number Item descrlptlon
.
Excavatlon maxlmum depth 10 - 15 m.
Excqvation in rock maxlmun depth 10 - 15 m
Concrete; wlth sylphate resistlng cement
strength 30 N/mm.
High yield steel bar rei.nforcement to
BS 4449 dameter 12 mm.
Hlgh yieJ.d steel bar reinforcement to
BS 4449 diameter 16 mm.
Hlgh yieJ-d steel- bar reinforcement to
Bs 4449 diameter 20 mm.
aterproofed
Jolns;
as Speclflcation
cl-ause C47.
^la^r lrrnhar c l:nlrran wll far
Gulde waLls.
Temporarv oround nchoraoes; East Otray wall:
Sgeclf i cat on c-lause
-W224
Number maximum depth 25 m.
Total length of tendons.
-
/*^+-o. urrta rl
hnrlznnl lnl 2? i
'i na :nl nrnrrt 1nc <
crnr:t tet i nd- brecrr
Number of dralns across sectlonal dlmension
not exceeding 100 n.
Depth of dralns of maxl-mum depth:
10 - 15 m cross sectional dimension
not exceedlng 100 mm; type C2
granular materlal,
Sand drai ns
sum
nr
t
t
t
m
n
3
m
3
m
3
m
nr
m
2730
40
66
120
,A'
50
650
7
140
2400
400
CESMM3 EXAMPLES
c613
c623
c64 0
c664
c 665
c666
c670
c68 0
clLt
c't2t
cB11
cB5 1
-,r.-t
30
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
D 100
D220
D250
D320
D4L4
D43 5
D54 5
D620
0900
Number Item descrlptlon Unlt Ouanflty Rate Amount

P
PRT 5. |IEMOT.TTTON ANN SJTR C.RARANCtr
Tre'es girth 7
- 2 m holes backfilled
wlth excavated mater1al.
"
Trees glrth exceedlng 5 m.
Stumps diameter 500 mm
-
1 m.
Bulldlngs brickwork volume 250 - 500 m3;
farmhouse at Far1ey Court.
Buildings masonry volume 500 - 1000 m3;
barn at Farley Court.
Other structures metal volume
500 - 1OOO m3; screenlng plant to remain the
property of the Employer.
Plpellnes nominal- bore 300
- 500 mm.
Pump removed, cJ-eaned and delivered to
Employer's depot at Church Stretton.
General- cJ.earance.
ha
nr
nr
nr
sum
sum
sum
nr
m 110
27
2
39
30
2t
PAGE
31
Number Item descrlptlon Unlt Quantlty Rate Amount
I

Excavation by dredging; Mersey estuary


adjacent to Sandon Dock.
ExcavatLon for foundations topsoil- maximum
depth: not exceedlng 0.25 m.
Excavation for. foundatlons maximum depth:
1 - 2 m.
Excavatlon for foundatlons maxlmum depth:
L - 2 n around piJ-e shafts.
Hand excavation for foundatlons maxlmum
depth: L - 2 m; Commencing Surface
underside of blinding of outfaLl.
General e-cavatjon
Topsoil maxlmum depth 2 - 5 m.
Maximumdepth2-5m.
Rock maxlmum depth: 2 - 5 m,
Mass concrete exposed at the Commenclng
Surface maxlmum depth: 1 - 2 m.
Rel-nforced concrete not exposed at the
Commencing Surface maxlmum depth: L - 2 m
EAgrso86.1.
Fl-c.vt I on anci I I arl es.
Trlmming of excavated surfaces.
Tr1mm1ng of surfaces; excavated by
dredging.
Preparatlon of excavated surfaces.
3
m
3
m
3
m
3
m
3
m
3
m
3
m
*3
3
m
3
m
2
m
2
m
2
m
10971
37
170
23
15
53
L12
7 500
153
1 7350
750
52"tL
15763
l
CESMM3 EXAMPLES
81,20
E31 1
8324
F'324.1
F.324.2
E415
E'425
8435
F.444
8454
8512. 1
8512.2
E552
32
PAGE TOT
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
EART{IIORKS.
E-cavat l on anc { I ar'l es .
Preparation of xcavated rock surfaces.
Preparation of excavated surfacesi mass
concrete.
Dlsposal of excavated materlal.
Dlsposal of materl-aL excavated by dredgtng.
Double handJ.lng of excavated materlal.
Excavatl-on of material beLow the Flnal
Surface and replacement with grade B
granular materiaL.
Tlmber supports left ln.
Metal supports left ln.
2
m
2
m
^3
a3
a3
*3
^2
2
m
*3
m3
2
m
2
m
5't 6
110
2700
10971
10350
1 000
300
500
527
100 ? 16
1054
357
Fllling to structures.
Ftlltng to embankments, seected excavated
material other than topsoll or rock.
Fllling anclllaries trlmmlng of fllled
surfaces; incllned at an angle of 10' - 45"
to the horlzontal.
FIIlJ.ng anclJ.Larles preparatl-on of fllled
surfaces.
EXAMPLE BILL OF OUANTITIES PAGES
8523
F'524
8532. 1
8532.2
8542
E560
E570
E580
E 613
8624
E? 12
8722
PAGE
33
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
Excvatlon for cuttings; topsoil.
Excavation for cuttlngs; Excavated Surface
0.25 m above Flnal Surface.
Excavation for cuttings; Commenclng Surface
0.25 m above FinaL Surface,
Excavatlon ancillaries preparatlon of
excavaton surface.
Excavation ancillarles disposal of
excavaed material; to on Site spoil heap
at locatlon A on drawing
'l/47.
FlJ.ling embankments selected excavated
materlaL other than topsoiJ- or rock.
Fllling ancillaries preparation of fllled
surfaces.
Filllng ancillarles geotextlles; melded
fibre mat grade G2 lald uon surfaces
lnclined at an angle of 1"0' - 45' to the
horizontal,.
3
m
m
3
m
3
m
2
m
3
m
3
m
2
m
584
105 87
680
5 110
584
5834
2187
1250
CESMM3 EXAMPLES

'E
E2L0
F,220.L
F'220.2
E'522
E532
F.624
8712
E730
It-
34
PAGE
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
PRT 28. STTEVIIORKS.
TIRTH!ORKS.
GeneraL excavatlon topsoll maxlmum depth:
not exceedlng 0.25 m.
General excavatlon maxlmum depth: 1 - 2 m.
D1sposal of excavated materiaf.
F11lIng embankments selected excavated
materlal other than topsoil or rock.
Fllling thickness 150 mm excavated topsoil.
Fllltng thlckness 150 mm lmported topsoil.
Flll1ng anclllaries trlmming of filled
surfaces, topsoil.
Landscapng turflng
Landscaping grass seeding upon a surface
inclined at an angle to the horizontal
exceeding 10'.
Landscaplng oak trees exceedng 5 m hlgh.
Landscaping sycamore trees exceed-tng
5 m high.
3
m
3
m
3
m
2
m
a2
2
m
nr
nr
3482
25234
9924
15310
232t3
1 573
1 7036
5700
2050
110
120
EXAMPLE BILL OF OUANTITIES PAGES
SITEIT'IORKS
E411
8424
8532
E.624
864 1
F.642
E711
EB 1O
E83r)
E860.1
EB60
"
2
PAGE TOT
35
CESMM3 EXAMPLES
STREFFORD BRDGE
F14 3
F634
8654
F664
F665
F666. I
8666.2
Number Item descrlptlon Unlt Qunllty Rate Amount
E p
Standard m1x ST4 cement to BS 12, 20 mm
aggreqate to BS 882.
3
m
3
m
3
m
3
m
a3
a3
3
m
840
462
96
38
53
87
104
laclng of concrete.
Rei nforced.
Suspended sl-ab thlckness: exceedlng 500 mm;
volded bridge deck.
Col-umns and piers cross-sectlonal_ area:
0.25 - 1 m2.'
Beams cross-sectlonal area: 0 .25 - I m2.
Beams cross-sectlonal area: exceedlng 1 m2.
Beams special sectlons: type Jl
drawlng L31 /26.
Beams speclal- sectlons: type ;I2
drawlng L37/26.
36
PAGE
Number
Item descrlptlon Unlt Quanllty Rate Amount
E p
IN STTU CONCRETE.
Provlsion of concrete. standard mlv.
ST3 cement to BS 12, 20 mm aggregate
to BS. 882.
ST4 cement to 8512, 40 mm aggregate to
BS 882.
ST4 sulphate resisting cement to
BS 4027, 40 mm aggregate to BS 382
3
m
3
m
3
m
3
m
3
m
m-
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
?
m
3
m
3
m
350
t032
504
3
97
2L0
2T
5
1
10
906
t5
r20
31
10
290
s20
97
Provlslon of concrete designed mix for
ornamentaL surfaces grade C25 cement to
BS L2, 20 mm aggegate; minimum cement
content 250 kg,/mr sampling as Specificatlon
cLause 252.
Plac{ng of concrete.
Mass bl-lnding thickness not exceedlng
L50 mm,
Mass backfilllng around structure; beneath
lnl,et channel pJ.aced against an excavated
surface.
Mass benchinq; wet weIls
Mass fill-ing to flume; inlet channel- to
pumping station.
Mass pllnths; 900 x 900 x 1000 mm.
Mass plinths; 1500 x 1500 x 1500 mm
Rein forced.
Bases and ground sl-abs thlckness
300
- 500 mm.
Ground slabs thickness: 300 - 500 mm; to be
placed ln one continuous pour in fllter
block base.
Suspended slabs thickness: 300 - 500 rnm
Wal-ls thickness: not exceeding 150 mm,
Wall-s thickness: not exceeding 150 mm;
weir wall- top finished to precise line
and level.
Wal-Is thickness: 150 - 300 mm.
300 - 500 mrn.
s cross-sectlonal area:
WalLs thlckness:
CoLumns and oler
0.1
-
0.25 m2.
EXAMPLE BILL OF OUANTITIES PAGES
INLET WORKS
F133
FL44
F14B
8253
F51I
F580. 1
F5B0
"
2
F580 .3
F580.4
F580.5
F623.I
8623.2
F 633
F641.1
864I.2
F 642
F64 3
F 653
PAGE
37
CESMM3 EXAMPLES
INIET WORKS
F65 4
F65 5
8664
F666. 1
8666.2
F666.3
F666.4
F'680. t
F680.2
F680.3
F680. 4
Number Item descrlptlon
Unlt Quantlty Rate Amount
E p
Colmns anQ piers cross-sectlonal area:
0.25
- 1 m2.'
Columns and plers cross-sectional area:
exceeding I mz; column cap.
Beams cross-sectional
area: 0 .25 - L m2
Beams speclal sectlons; 600 x 900 mm
(lnterna.l-)
box beam, wall- thickness:
150 mm.
Beams special sections; type J3
drawing I31 /21 .
Beams speciaL sectlons; type J4
drawlng L37 /21 .
Beams special sections; type ,15
drawing L37/2'7.
Dlffuser drun thickness lS0 mm, diff::ser
type D1 drawlng t3'7/49.
Box cuLvert lnternaL dimenslons 1.5 x 3 m
wal-1 thickness: 250 mm.
Box culvert internal_ dimenslons 2 x 4 m
wal1 thickness: 250 mrn.
Steps and stalrs thickness: 100
- 300 mm.
TN STTII CONCRETF]
Other concrete forms,
Pl:clnc of concete.
3
m
3
m
3
m
a3
3
m
3
m
3
m
3
m
3
m
3
m
3
m
94
67
16
98
66
78
3
10
70
L2
104
38
PAGE
Number
Item descrlPtlon Unlt Ouantty Rate Amount
p
Formwork rough flnlsh horlzontal- wldth
0.1 - 0.2 m.
Formwork rough finish horizontal wldth
0.2'- 0.4 m to be left in.
Formwork rough finish vertlcal.
Formwork rough finish curved to one radius
in one plane; radlus 10.5 m, back of wall
D drawing 1-3'l / 6 .
Formwork rough finish for concrete
component of constant cross-section; box
culvert internal dimensions 1.5 x 3 m wal-l-
thickness: 250 mm.
tr'orrnwork fair fini sh.
Horizontal wldth not exceeding 0.1 m.
Horlzontal width 0.2
-
0.4 n.
Horizontal.
SJ-oping width G.l
- 0"2 m"
Sloping wldth 0.1 - 0.2 m; upper surfaee
S loping .
Sloping; upper surface.
Battered.
Vertical- width not exceeding 0,1 m.
VertlcaL width 0.1 - 0,2 m.
Vertical width 0.2
-
O.4 m,
VerticaI.
Curved to one radius 1n one plane wldth
0.15 m; radius 1.0 m, column plinths.
Curved to one radius in one pJ-ane radius
11 . 5 m; face of wal-l- D drawing L37 / 6 ,
Spherlcal radlus 2 m; fLume chamber.
Conical maximum radius 600 run minimum
radius 300 mm; outl-et chamber.
Conical maximum radius 800 mm minimum
radius 400 mm; inlet chamber.
m
m
2
2
m
2
m
m
m
2
m
2
m
m
m
2
m
2
m
2
m
m
m
2
m
2
m
m
2
m
2
m
m
2
m
129
7
370
99'7
326
410
331
981
723
27
r28
157
429
410
924
I92
780
927
1354
43
21
35
EXAMPLE BILL OF OUANT IES PAGES
GTL2
c1L 3
Gl4 5
Gl5 5
G184
G2LT
G2T3
GzI5
G222
"r
c222.2
e225.L
G225.2
G235
c24l
e242
c243
G245
c252
c255
c260.L
c260.2
c260,3
PAGE
39
CESMM3 EXAMPLES
G2'IL
c212
c21 6
G218.L
c2'18.2
c281.1
G28L.2
c281.3
G282
"l
c282.2
c282.3
c284
c28 5
c286
c299
Amount
E
P
Ouantlty Rate Unlt
Item descrlptlon Number
CONCRETE ANCTT,T,RTES,
'ormwork fal r f n1 sh.
For'small voids dePth
For small voids dePth
For large volds dePth
For large volds dePth
For large volds dePth
For concrete comPonents of constant
cross-section .
Beams; 200 x 300 mm beam 827.
Beamsi 300 x 400 mm beam 828.
Beams; 450 x 600 mm beam 830.
Columns; 450 x 450 mm columns I '' 24"
Columns; 600 x 600 mm columns 25 - 30.
Col.umns; curved to 150 mm" radius columns
31 - 54.
Box culvert lnternal dlmension 1.5 x 3 m
wall thickness 250 mm beneath entrance
road.
ProJections.
Intruslons.
not
0.5
2.3
2.3
2,6
exceeding 0.5 m.
-
1m.
m.
m.
m.
m
m
m
m
m
m
m
m
m
m
nr
nr
nr
nr
nr
5
15?
2gs
76
5
L
37
50
46
98
27
95
310
207 6
15 94
For diffuser drum lncluding
perforatlons
as detailed on drawlng I37 /54.
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
c51 1
c5t2
G5L3
G514
G515.1
c515.2
G516.1
c5I6. 2
c516 . 3
G517 . t
G577 ,2
c518
c526.1
c526,2
G528
c563. 1
c563.2
G5 64
Number Item descrlptlon Unlt Quantlty Rate Amount
I p
CONCRFITE ANCTI,LRTES
Rel nforcernent
Paln round steel hars to RS 4449-
Dlameter 6 mm.
Dlameter I mm.
Dlameter 10 mm.
Diameter 12 mm.
Dlameter 16 mm.
Dlameter 15 mrn; Iength 15 m.
Dlameter 20 mm.
Dlameter 20 mm; length 15 m"
DLameter 20 mm; Iength 18 m.
Diameter 25 rnm.
Diameter 25 mn; length 15 m.
Dlameter 32 run or greater.
t
t
t
t
t
t
t
t
t
t
t
t
t
t
2
m
2
m
2
m
3.7
3.9
4.2
4.9
5.7
2.r
5.9
1.0
0.9
6,3
r,2
1,6
4.2
2.r
3.9
3'128
1807
286
Deformed hlgh yieJ-d steel bars to BS 4449
dlameter 20 mm.
Deformed hlgh yield steel bars to BS 4449
dl-ameter 20 mm; length 15 m.
Deformed high yleld st,eeL bars to BS 4449
diameter 32 mm or greater.
Steel
3-4
Stee.l-
3-4
Steel
4-5
fabric to BS 4483 nominaL mass
kg/n2; reference 4193.
fabrlc to BS 4483 nominal mass
kg/m2 reference 4252.
fabrlc to BS 4483 noml-nal- mass
kq/m'; reference C503.
L-_
PGE TO
41
CESMM3 EXAMPLES
G62I
c622
c64 1
c642
c643. I
c643.2
c65 I
G652
c653
c654.1
c654.2
G670.1
c610.2
G682.t
c682.2
Number Item descrlptlon Unlt Quantlty Rate Amount
p
CONCRRTE NCTT,T,RTFIS.
Joi,nt s
25 mm hitr:men impregnated fibreboard filler
Open surface width: not exceeding 0.5 m.
Open surface bridth: 0.5 -. 1 m.
Formed surface width: not exceedlng 0.5 m.
Formed surface width: 0.5 - 1 m.
Formed surface width: 1.2 m.
Formed surface wldth: 1.45 m.
m
m
m
m
m
m
2
2
2
2
2
m
m
m
m
m
m
m
nr
nr
9't
38
107
9B
21
41
38
110
150
28
64
I25
670
r28
3t_
PVC centre bulb waterstop; 100 rnm wde
PVC centre bulb waterstop,. 175 mm wLde
Rubber centre bul-b waterstop; 225 mm w1de.
Rubber centre buLb waterstop; 400 mm wide
Rubber centre bulb waterstop; 450 mm wide
Rebate sealed with 25 x 25 mm Plastic or
slmllar approved.
Rebate sealed with 25 x 25 mm PJ.astljolnt
or similar approved.
Sleeved and capped dowels; 25 mm dlameter
by 300 mm mild steel bars at 0.5 m centres
as detail E drawlng I3'l/25.
Sl-eeved and capped dowels; 25 mm diameter
by 300 mm mild steel- bars at 1 m centres
as detail E drawing L31/2.
42
PAGE
Number Item descrlpton Unlt Quantlty Rate Amount
I p
CONCRETR NCTf .I,RTRS.
Concrete ccessorles.
Flnishlng of top surfaces wood float.
Flnishlng of top surfaces steeL trovrel.
Finishing of top surfaces granolithc
finish; as Specification clause GBl05,
40 mm thick; steel trowel- surface
treatment.
Finishlng of top surfaces granollthic
flnish; as Speclflcation clause G8/05,
55 mm hicki steel- trorrel" surface
treatment.
Flnishing of top surfaces cement and sand
screed as Speciflcatlon clause G8,/1.2, 40 mm
thlck; steel trowel surface treatment.
Flnishlng of formed surfaees bush
hammering.
2
m
2
m
*2
2
m
2
m
*2
m
nr
nr
nr
nr
nr
nr
nr
491 6
1 0821
L92
141
98
481
21
110
110
64
10
3
4
I
Tnserts
100 mm dlameter GVC plpe; excludlng supply
of the pipe.
10 mm diametex, 25 mm deep expanding boj-t
projecting from one surface.
15 mm dlameter, 40 mm deep rag bolt
proJecting from one surface.
25 mm dlameter, 100 mm long mlLd steel
holdlng down bolt projectlng from one
concrete surface for scraper machlnery'
as detall L drawlng I38/J-'1.
100 run diameter ductiJ.e lron plpe
proJecting frorn one surface; excJ-uding
supply of pipe.
150 mm diameter ductile lron plpe with
puddle flange projecting from two surfaces;
excludlng suppl.y of pipe.
225 mm dlameter ductlle iron pipe
proJectlng fron two surfaces grouted vIth
grout type G3 Into 450 x 450 mm preformed
opening; excludlng supply and flxlng of the
pipe under separate contract.
Groutlng under plates area 0.1 - 0.5 m2
with type G2 grout,
EXAMPLE BILL OF OUANTITIES PAGES
G81 1
G812
G814.1
c8I4.2
GB 15
c822
G83 l
c832. 1-
c832.2
c832.3
c832.4
c832.5
c832. 6
G842
PAGE
43
Number Item descrlptlon Unlt Quantlty RatE Amount
I p
PRECAST CONCRETT
Ord'inary prescribed mix concrete orade C40
as Specifi cati on cl ause F 2/36.
Strefforcl Bridge fieck.
Secondary beams lnverted t,ee 180 x 400 mm
length 4.25 m mass 500 kg-lt mark 81.
Secondary end beams rectangular 200 x 450 mm
length 4 .25 n mass 500 kg-It mark 82.
Prestressed pre-tensioned maln beams I
section 800 x 1400 mm length 23,1 m mass
31 t mark 83 prestresslng as drawing 136/21
and Specificatlon cLauses H2/2L-21.
Service duct cover slabs thickness 100 mm
area 1 - 4 m2 mass 500 kg-J-t mark 51.
Parapet coplng nlts flLleted rectangul
250 x 220 mm cross-sectional area 0.05
mass 120 kglm mark CL.
ar
*2
nr
nr
nr
nr
m
32
4
z
28
124
CESMM3 EXAMPLES
BRIDGES
Hl13.1
HTL3.2
H268
H523
H8 l0
M
PAGE
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
PIPEW9BK_J.IPE.1
Clav ppes to BS 65 with splgot and socket
f le-ibl e
Jolnl
s nomi na] bore 225 mm { n
treFches.
Between manhol es 7 encl I 1.
Depth:1.5-2m.
Depth:2-2.5n.
Depth:2.5:3m.
m
m
m
fn
m
m
m
m
m
187
29r
L02
113
202
98
r27
78
2t
Retween menholes 27 nd 31
Depth:1.5-2m.
Depth:2-2.5n.
re st re.sed-locretdpes_to_lS_191-l
fclass Ml wii.h ogee
Jolnts
nomina
375 mm,
Betveen manholes 18 and 19 lnstalJ-ed by
thrust boring under Central lal-es line
rallway embankment.
Depth:2-2.5m.
Depthl 2.5-3m.
Depth:4.5-5m.
EXAMPLE BILL OF OUANTITIES PAGES
SITE PIPEI,INES
r123.1
TT24.L
f125
t123.2
rt24.2
T23T
r234
r235
T23B
PGE TO
45
CESMM3 EXAMPLES
SITE PIPELINES
T233
I34 1
r343
134 5
r 346
15t2
r513
r 514
\
Number Item descrlptlon Unlt Quantlty Rate Amount

p
P-IPEWARK_-
P-I!.E.I
restresserl concrete p,lpes to BS 5911
llcc M wifh
^
-{^i
-+ - -^-i
- 1
3?5, mm.
Manhole 23 to orimary tank.
Depth 1 .5 - 2 m; in trench laid alongside
second pipe.
m
m
m
m
2'7
16
L2
33
33
15
150
1.28
Ducti le spun iron plpes to trS 4622 fclass 3l
with Forsoam joints nominal bore 700 mm.
Feed plpe suppotted above the ground.
In trench depth 1.5 - 2 m Commencing
Surface underside of main tank slab; draw
off pipe main tank colector to valve
chamber.
In trench D depth 2.5 - 3 m bypass
Pressure
maln valve chamber to circulation unlt.
In trench D depth 3 - 3,5 m servlce maln
valve chamtrer to circuLaLiorr unit.
Upvc
pipgs
to FS 3505 with compresslon
la'if c ^irI rnra
Tn trenches.
Depth: not exceeding 1.5 m; excavatlon
by hand.
Depth:1,5-2m,
Depth:2-3m.
46
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
SITE PIPELINES
f
I
JII2
Jl22
JI32
J2L2
J2r3.t
J2t3,2
J2T4
J222
J223. r
J223.2
J224
J232
.I233
J234
I
J
Amount
p
Unlt Ouantty Rate Item descrlptlon
Number
PTF!{ORK
-
F'ITTTNGS ANN V,VFS.
Tapers
Bends.
Junctlons and branches
Prestressed concrete pipe flttlnos to-
RS 5911
(class
Ml wlth ogee
Joints.
Bends; nominal bore 225 mm.
Bends; nominal bore 375 mm.
Bends; nominal bore 450 mm.
Bends; nomlnal bore 825 mm.
ilunctlons and branches,' nomlnal bore
225 r,n.
Junctlons and branches; nomfnal bore
375 mm"
,Junctlons and branches; nominal bore
450 mm.
.Junctions and branches; nominaL bore
825 mm.
Tapers; nominal bore 225 mm.
Tapers; nomlnal bore 450 mm.
Tapers; nominal bore 825 rnm.
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
27
't6
I
385
L27
38
4T
141
19
41
23
16
16
4
PAGE TO
47
CESMM3 EXAMPLES
SITE PIPELINES
J31 1
J313 . I
.t31.3 . 2
J313.3
J353
J382. 1
,r-?8? , ?
J3B3
.j393
J813.1
J813 . 2
J8r3.3
J83 5
,tBB4 , 1
JBSS.2
JB94
I
i
Amount
E
p
Unlt Quantlty Rate
Number Itom descrlptlon
PTPFORK
-
F'TTTTNG NN VAT,VFS.
frrrctlle spun lron plpe fittlngs to
RS 4622
(class
3 wlth GripDon
Joints.
Benps; normal- bore 150 mm.
Bends; nominal bore 400 rn 22.5' effectlve
length 220 m; not In trenches.
Bends; nomlnal bore 400 mm 45 effectlve
Iength 400 mm.
Bends; nominal bore 500 mm vertical 90'
effectlve length 840 mm.
Adaptors; nominal bore 400 mm Grippon to
flange effectlve length 150 run.
Straight specials nomLnaL bore 225 mm
effective length 1220 mm.
St:'alght speeials nomlnal bcre 225 mm
effective length 1500 mm; with puddle
flange.
Straight speclals nomina bore 400 mm
effectlve length 900 mm; not in trenches
Blank flanges; nclminal bore 400 run
Cast iron gate valves hand oPerated to
RS 3464 ltype al with evtension sPlndes.
400 mm nomlnal bore with T keY.
400 mm nominal bore wlth hand wheeI.
500 mm nominal bore with hand wheel.
Cast iron valves as F{oldwater Tndustries
cataloQrue numbers sated or smller
agoroved.
Double hinged flap val.ves nominal bore
1100 mm nr 890.
Penstocks nomlnaf bore 700 mm nr 731 wlth
handwheel- headstock and foot bracketi
invert to handwheel dlstance 2050 run.
Penstocks noml,nal bore 700 mm nr 740 with
T key headstock and foot bracket; invert
to T key dLstance 3100 mm.
Sludge draw off valves nomlnal bore
700 mm nr 780.
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
n!
27
1
6
3
6
1
1
2
6
9
3
3
3
4
2
3
48
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
SITE PIPELINES
J31 1
J313 . 1
J3T3,2
,t31.3 . 3
.t353
,J382. 1
J382,2
J3B3
,r393
J813. 1
J813 . 2
J813 . 3
J83 5
J884.1
J884.2
Amount
p
Unlt Ouantlty Rate
Number ltem doscrlptlon
PTtrlfORK
-
F'TTTTNG ANN VT.VRS.
Ductlle spun lron plpe fltt{ngs to
FS 4622 (clss
3) hrlth Grippn
Jonts.
Bends; normal bore 150 mm.
Bends; nominal bore 400 rw 22.5' effectlve
length 220 n not In trenches.
Bends; nomlnal bore 400 mm 45 effectlve
length 100 mm.
Bends; nomLnal bore 500 mm vertlcal 90'
effectlve length 840 mm.
Adaptors; nomlnal bore 400 run Grippon Eo
flange effective length l-60 mm.
Straight specials nominal bore 225 mm
effective length 1220 mm.
Stralght speclals nomlnal bore 225 mm
effectlve length 1500 mm; wlth puddJ.e
flange.
Stralght speclals nomlnal bore 400 mm
effectlve J.ength 900 mm; not in trenches.
Blank flanges; nomlnal bore 400 mm.
Cast iron gate va]ves hand oPerated to
RS 3464
(type
al wlth e-tension so{ndles.
400 run nomlnal bore with T key.
400 mm nominal bore wlth hand wheel-.
500 mm nomlnal- bore wlth hand wheel.
Cast i ron val ves as Ho] dwater Tndustr'l es
catalogrre numbers stated or slml Iar
agproved.
Double hinged flap valves nominal bore
1100 mm nr 890.
Penstocks nomlnal bore 700 mm nr 731 with
handwheel headstock and foot bracketi
lnvert to handwheel dlstance 2050 mm.
Penstocks nominal bore 700 mm nr 740 with
T key headstock and foot bracket; invert
to T key distance 3100 mm.
Sludge draw off vaLves nomlnal bore
?00 mm nr 780.
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
27
t
6
3
6
1
1
2
6
9
3
3
3
4
2
3
,J894
PAGE TO
49
CESMM3 EXAMPLES
CHAT MOSS PIPELINES
Kl1 1
K112.1
KTL2.2
KL22.L
Kr22.2
Kt 52
K21 1
K360
K4 10
K433
K434
K4 53
Number Item descrlptlon Unlt Quantlty Rate Amount
p
pTRIORK
-
MNHOT,ES ND TpRf/rlORK
AN.CLIJ.ITBI.L.
Manholes
Brlck depth not exceedlng 1.5 m; excavated
by hand; type Al with medium duty cast lron
cover to BS 497 reference MB1-55.
Brick depth I.5
- 2 m; type A1 with heavy
duty triangul-ar cast iron cover to BS 497
reference MA-T,
Brlck depth L5
-
2 m; type A2 with medlum
duty cast iron cqver to BS 497 reference
MB2-55.
Brick wlth backdrop depth I .5 - 2 mi type
410 with cast lron cover to BS 497
reference MC2-60/45.
Brlck wlth backdrop depth 1.5 - 2 m;
type 420 with cast iron cover to BS 497
reference MCl-60,/60.
Precast concrete depth I.5 - 2 rn; type Cl
wlth triangul.ar cast iron cover to BS 49?
reference MA-T.
nr
nr
nr
nr
nr
RT
nr
nr
3
m
m
m
m
1
'l
4
5
3
33
6
15
310
54
89
2B
Catch plts brlck depth not exceedlng 1.5 m;
type Kl with l-ight duty cast iron cover to
BS 497 reference C6-24/24.
GuLLles precast concrete trapped; wlth
medium duty straight bar gulley grating to
BS 497 reference El2-L2.
Fllllng of French and rubble drains with
graded material; type C3 granular materiaL
Trenches for unpiped rubble draln
cross-secti.onal aiea 0.5 - 0.75 m2.
Trenches for unplped rubbl-e dralns
cross-sectlonal aiea 0.75 - 1 m2.
Rectangular sectlon ditches cross-sectional
area 0.5 - 0.15 m; tined wlth L000 g
auge melded flbre mat.
50
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
CHAT MOSS PIPELINES
K542
K543
K553
K623.r
K623.2
K64 I
K61 L
K612
K682.I
K682.2
K683
K71 I
Unit Quantlty Rate Amount
p
Item descriptlon
Number
ANCTLT.ARIF]S .
Unglazed vltrified clay 4 way 100 mm
nominal bore cable duct loose
Jointed
in
trenches depth not exceeding 1.5 m
beneath roads.
Unglazed vitrified cJ-ay 4 way 100 mm
nominal bore cabl-e duct oose
jointed in
trenches depth 1.5
-
2 m beneath roads.
Sectional corrugated metal culverts as
Specification clause K5613 nominal
interna diameter 700 mm in trenches depth
I.5
-
2 m in outfal-l-.
C ros s in gls,
River width 3 - 10 m pj-pe bore
900 - 1800 mm.
Canal- width 3 - 10 m,'
PiPe
bore
300 -
900 mm.
Hedge; pipe bore not exceedlng 300 mm.
sewer or drain; pipe bore not exceedng
300 mm.
Sewer or drain; pipe bore 300 - 900 mm.
Gas main; pipe bore 300 - 900 mm.
Existing sludge draw off pipe line: pipe
bore 300 - 900 mm.
Underground high voltage elect,ric cable:
pipe bore 900 - 1800 mm.
nr
NT
nr
nr
nr
nr
nr
nr
m
m
m
m
m
1,4
25
63
387
284
2
2
1
4
30
15
1
2
Breaking up and temporary reinstatement
of roads flexible road constructlon
maximum depth 75 mm with 250 mm sub-base;
pipe bore not exceeding 300 mm.
Breakng up and temporary reinstatement
of roads reinforced concrete slab depth
200 mm with 250 rnm type L 3ub-base; plpe
bore 300 - 900 mm.
Re i nst atement .
K1L2.T
PAGE
51
Number Item descrlptlon Unlt Ouantlty Rate Amount
p
PTPEWORK
-
MNHOT,ES ANN PTPEWORK
AN.ILBJ.I.
Breaking up and temporary reinstatement
of foads flexi-ble road construction
maximum depth ?5 mm with 250 mm type 1
sub-base; pipe bore 300 - 900 mm.
Breaking up temporary and permanent
reinstatement of footpaths precast
concrete paving flags maxlmum depth 75 mm
with 50 mm sand bed; plpe bore not
exceedlng 300 mm.
Strip topsoil from easement and reinstate
in cultivated land; mlnimum wldth 20 m.
m
m
m
m
nr
2
m
nr
783
54
3't26
241
41
450
I
l. har ni nourar nl I I vi ac
ReLnstatement of field ciraLns.
Marker posts; 100 x 100 x 1500 mm hardvood
set in concrete base as drawing 1,37/15
detail- C.
Timber supports eft ln excavatons.
Connectlon of pipes to exlstlng manholes;
nominal bore 200 - 300 mm; fouf water sewer
lncuding breaking into manhole,
reforming benching and dealing with flows
in accordance wlth detail-7 drawing c3/21.
CESMM3 EXAMPLES
CHAT MOSS PIPELINES
K712.2
K14]-
K760
KSrCr
KB2O
K83 0
K852
52
PAGE
Number
Item descrlptlon Unit Quantlty Rate Amount
E p
PTpFTORK
-
SLpORTS Nn
pROTFCTTON
NCTf,T,ARTFS TO T,YTNG NN RXCAVATION.
Extras to excavation ad backfi lllng
in nlna i^he
Excavation of rock.
3
m
Excavation of mass concrete.
Excavatlon or rei.nforced concrete.
Backfilling above the Flnal Surface wlth
concrete; mix ST 1.
3
m
3
m
Backfllling above the Flnal- Surface with
imported natura materlaf other than rock
or topsoil.
Excavation of natural material brelow the
F1nal Surface and backfllllng wlth
concrete: mlx ST 1.
Excavatlon of natural materlal below the
Final Surface and backfilling wlth type C2
granular materiaL.
3
n
3
m
Hand excavatlon of natural material bel-ow
the Final Surface and backfllling with
type C3 granular material.
E-tras to e-cevation nd backfi l li no
In manhol-es and other chambers excavation
of rock.
In manholes and other chambers: excavatlon
of mass concrete.
In thrust borlng: excavatlon of rock.
3
m
Speclal p'l pe I ayl ng methods.
Thrust boring pipe nominal bore
300 -
600 mm; manholes 18 to 19. m
460
65
B5
2
310
260
274
230
27
4
L27
98
EXAMPLE BILL OF OUANTITIES PAGES
CHAT MOSS PIPELINES
Ll11.
LLI2
L113
Ll15
L1- 16
Ll17
L118. L
L11B
"
2
LL2T
LT22
L14 1
L223
PAGE
53
CESMM3 EXAMPLES
CHAT MOSS PIPELINES
],33 1
L332
13 52
L353
L4;l I
L432
L531. 1
L531.2
L60 1
Number
Item descrlptlon
Unlt Ouantlty Rate Amount
p
TPE!IORK
-
SUpORTS ANf
pROTF.CTTON
NCI,I,ARTFS TO T,AYTNG ANI RXCAVATTON
Imported granular
materlal- type C2
pipe nominal bore not exceeding 200 mm.
Imported granular
material type C2 plpe
nominal- bore 200 - 300 mm.
Relnforced concrete mix ST 3 reinforced
as drawlng I3'7/I9 detall B pipe nomlnal_
bore 200
- 300 mm.
Reinforced concrete mlx ST 3 relnforced
as drawing I3'7/19 detalt pipe nominaL
bore 300
- 600 mm.
Reds depth 1 50 mm
Imported granuJ_ar
materlal_ type C2 ptpe
nomlnal- bore not exceeding 200 mm; be
depth 200 mm.
Imported granular
materlal type C2 plpe
nomlnal- bore 200
- 300 mm; bed depth
200 mm.
llarrnches.
Imported granular
materlal type C2 plpe
nominal bore not exceeding 200 mm; bed
depth 200 mm.
Imported granular
materiaL type C2 to two
pipes, maximum dj_stance between inside
face of outer wal_ls of pipes 600 mm; bed
depth 200 mm.
Reds and surrounds.
Surrounds
Ialrapping and lagging p.pe nominal bore not
exceedlng 200 mn with lrlrapo.
m
m
m
m
m
m
m
m
m
27
2483
L25
50
250
402
41
20't
90
54
PAGE TOT
Number
Item descrlptlon Unlt Quantlty Rate Amount
E p
PTPFI!IORK
-
StlppORTS ANf' ROTFICTTON
NCTT,T,ARIRS TO I,AYTNG ANI' FIXCVTTON
Stools and thrust blocks
VoJ.ume 0.1 - 0.2 m3 concrete grade c21
plpe nomlnaL bore not exceedlng 200 mm.
Volume O.2
- 0.5 m3 concrete grade G21
pipe nominal bore 200
-
300 mm wih strap
as drawing 3/27 detatL 5.
nr
nr
nr
4
2
3
Isol-ated pipe support; height 1 - 1.5 m
plpe nomlnal bore 200
-
300 mm; 1200 mn
long hanger, 6 run galvanized mll-d steel as
drawfng 3/27 detaLL 3.
EXAMPLE BILL OF OUANTITIES PAGES
CHAT MOSS PIPELINES
L72I
L732
L822
PGE
55
CESMM3 EXAMPLES
M31 1
M32I
M351
h
M353
M3 51
M37 0
M380
M620
M632
M662
M810
M870
Ir
Number Item descrlptlon Unit Quanllty Hate Amount
I p
STRUCTURAL MFTAT,WORK.
a^irir^r
^.t
rtr v. a+^^l
^--^
?r
F'abricat i on of members for frames
stra oht on pl n.
Coumns.
Beams.
Roof trusses comprislng single
70 x ?0 x B angle rafters and 50 x 50 x 6
InternaL and bottom ties.
Bu1lt-up side girders cambered comprlslng
two single 150 x 90 x 12 angles top boom,
two single 150 x 75 x 12 angles bottom
boom with verticals ?0 x 70 x 8 angJ-es,
diagonals 70 x 70 x 8, B0 x 80 x B and
90 x 90 x 10 angles.
Bracings, purlins and claddng rails.
GriJ-J.ages.
Anchorages and holdlng bolt assemblies
cmprising 4 nr 450 x 24 bolls with plates
150 x 150 x 10.
t
t
t
t
t
t
nr
t
nr
nr
m
m
2
r.4
0.9
0.9
2.6
L.1
0.4
4
7.9
150
84
24t
241
Rrection of conveyor gantry.
Frame members,
Site bol-ts black diameter 16 - 20 mm
HSFG load indlcating bol-ts diameter
16 - 20 mm wth washers.
Convevor gantrv e-amoe C. steel grade 434
Off Site surface treatment.
Blast cleanlng to BS 4232 second quality.
Palnting one coat zinc epoxy prlmer.
56
PAGE TO
Number
Item descrlptlon Unit Quantily Rate Amount
I p
MSCET,LNEOUS METT,VIORK
Stalrways and landlngs; stalrcase 53
drawing L36/2'l .
Stairways and landings; staircase 54
drawing 136/28.
Galvanised mlld steeL l-adders; stringers
65 x 13 mm, 400 mm apart, rungs 20 mm
diameter at 300 rnm centres; stringers
extended and returned 1000 rnm to form
handrail.
Gal-vanised miLd steel Iadders; stringers
65 x 13 run, 400 mm apart, rungs 20 mm
dlameter at 300 run centres; stringers
extended and returned 1000 mm to form
handrail; wlth safety cage of 3 nr
65 x 13 mm verticals and 65 x 13 mm hoops
750 mm diameter at ?00 mm centres cage
commencing 2500 mm above commencing leveI
Miscel-laneous framing; galvanised m1Id
steeJ. angle section 64 x 64 x 9 mm.
Mlscel-Laneous framing; galvanised miJ-d
steel angle sectlon 38 x 38 x 6 mm.
Plate floorlng; galvanlsed mlld steel-
cheguer pJ-at.ing 10 mm thick as detaled oi
drawing 136/42.
Open grid floorlng; galvanised mild steel-
to BS 4592 as detail-ed on drawing I37/49.
Duct covers; galvanised mild steel
10 mm thick, width 300 mn as detailed on
drawing L31 /50,
Covered tanks vol-ume 100
-
300 m3;
galvanised mil-d steel- to BS417 part I
reference T40.
Gal-vanised mild steel adjustabJ-e V-notch
weir plate to precise l-evels as detalled
on drawlng 136/7 detail A.
Cast iron light duty lnspection cover to
BS 497 reference C6 - 24/24.
Supp1y cast iron step irons to BS 1247
type a2.
SuppJ.y 2200 x 2200 run galvanised mild
steel forebay screen as detalled on
drawing 1,36/98.
t
t
m
m
m
m
2
m
2
m
2
m
nr
m
nr
nr
t
3.'t
4.5
14
24
24't
53
86
47
27
3
137
2
t2
L.4
EXAMPLE BILL OF OUANTITIES PAGES
N1l0.l-
N110.2
N130.1
N130.2
N161.1
N161.2
N1 70
N180
N23 0
N28 6
N999.1
N999.2
N999.3
N999.4
PAGE TO
57
CESMM3 EXAMPLES
DOCK 3
or22
or23
014 3
tr
oL52
o15 3
02L1
o2r2
o213
0242
o243
Number Item descrlptlon Unlt Quantlty Rate Amount
E p
TTMRER
Hardwood comognents cross-sectional re
0.0
-
0.02 r: wrouoht finlsh,
150 x'?5 mm Greenheart length 1.5 - 3 m.
150 x 100 mm Greenheart length 3 - 5 m;
pier decking runners.
m
m
m
m
m
m
m
m
184
204
163
28'l
364
196
47
280
48
440
Hardwood components cross-sectonal area
0.04
-
0.1 rr: wrought flnsh.
300 x 300 mm Greenheart J-ength 3
-
5 m;
pler braces between pl1es.
Hardwood co$ponents cross-sectionl area
0.1
-
0.2 n: wrought flnish.
350 x 350 mm Greenheart length 1.5 - 3 m
400 x 400 mm Greenheart length 3 - 5 m;
pier decking bearers.
Softwood components
ross-sectional
area
not evceedino 0.01 rr: wrouoht f i ni sh.
75 x 75 mm DougJ-as flr tanalized length
not exceeding 1.5 m.
100 x I00 mm DougJ-as fir tanalized length
1.5
-
3m.
100 x 50 mm Douglas flr tanaLlzed with
rounded edges length 3 - 5 m; hand rall
Softwood components cross-sect{ona' area
0.04
-
0.1 n: wrought fnlsh.
150 x 300 mm DougJ-as fir length 1.5 - 3 m
225 x 3OO mm DougJ.as fir length 3 -
5 m,'
pier rubbing pece.
58
PAGE TOT
EXAMPLE BILL OF OUANTITIES PAGES
DOCK 3
0330.
1
0330.2
0510
o520
0540.1
a540.2
o550

I
I
Number
Item descrlptlon Unlt Ouantlty Rate Amount
E p
150 x 70 run Greenheart
250x70mGreenheart.
2
m
2
m
nr
nr
nr
nr
nr
786
260
10
50
50
40
10
Flttlngs nd fstenlngs.
Gal vanised mi I d stee l
.
Straps glrth: 457 mm wldth 50 mm thLckness
5 mm as drawlng D3/2'l .
Splkes: Iength 75 mm.
Bolts: J.ength 75 mm, dlalqeter 5 mm.
Bolts; stalnLess steel length 100 mm
dlameter 6 mm.
Plates; stalnless steel 100 x 100 mm
thLckness 6 mm.
PAGE
59
Number Item descrlptlon Unlt Cf,antlty Rate Amount
E p
Pl l ing to Prrmplng Sttlon.
aannaninn arrrf:o ?? r n l
Rored cast in pace plles concrete grde
C25' as Sgeclflcatlon clause 713.3.
l''llameter 900 mm.
Number of plles.
Concreted length.
Depth bored maximum depth 18m.
nr
m
m
nr
m
m
97
1 195
1305
42
932
992
filameter 1200 mm raked at incllnatlon
ratlo l:6.
Number of piles.
Concreted ength.
Depth bored maxlmum depth 35 m.
CESMM3 EXAMPLES
PUMPING STATION
P 151
PL52
P 153
P 161
i L9
P 163
60
PAGE TO
EXAMPLE BILL OF OUANTITIES PAGES
BRIDGE
P331. L
P33 1 .2
P332
P351. 1
P35 1 .2
P352
tr
Unlt Quantlty Rate Amount
I
p
Item descrlptlon
Number
Soecl ficatlon clause ?13.4 relnforcement
Number of piles length 8.5 m; mild steel
drivlng heads and shoes.
Number of plles length L2.5 t, mlld steel
drivlng heads and shoes.
Depth drlven.
PLUsLo-,.Bddce.
aannana errf:a +n
L^
^-
^ -^
1
300 mm
reformed pl es concrete grade C25 as
Speci flcatlon clause 713-4 relnforcement
as detall 5 on drawlng |3?/65 nomlnal
r.lrcrrlar rllameter 450 mm.
Number of plles length 12.5 m.
Number of plles length I7.2m.
Depth driven.
nr
nr
nr
nr
m
10
t7
284
L2B
40
2720
PAGE
61
CESMM3 EXAMPLES
P IER
P 651
P 652
Amount
I
P
Unlt Ouantty Rate
Number Item descrlptlon
:
0-15
-
0.25 : 400 Y 4OO mm Greenheert'
Commencino Surface to be Origlnal Surface
of bed of Rlver Corve,
Number of plJ-es length 7.5 m; galvanlsed
mild steeL driving head and shoe as detail
5 drawing L40/'l .
Depth drj.ven.
eilf-ro--e&.r.
104
630
62
PAGE
Numbcr
'ltcm.deccrlptlon
Unlt Quantlty Rato Amount
I p
PTT.TNG
'NO
SORAGE
TTNK.
Tnterlockngr grrade 43 stee plles
Conrmenclng Surface 300 mm below Orlglnal
Srrrface.
Length of corner plles.
-
Iength of taper plles.
Driven area.
Area of plles of length: not exceedlng
14 mi treated with two coats bltumen paint
Area of plles of length: 14 - 24 m;
treated wlth two coats bitumen'palnt
m
m
a2
m
*2
44
21
684'l
3764
4i1
EXAMPLE BILL OF OUANTITIES PAGES
STORAGE TANK
P831.1
P83L.2
PB32
P 833
P 834
PAGE
63
CESMM3 EXAMPLES
PUMPING STATION
Qr25
Q135
Qlss
Q15 6
Q1B 5
QLB 6
Q2LL
Q2I2
Q700
Unlt Ouantty Rate Amount
E
p
Item descrlption Number
Cs.t In pl ce concrete oi es.
Backfilllng empty bore with selected
excavated materia diameter 900 mm.
Permanent caslngs each length not
exceedlng 13 m, dJ.ameter 900 mm diameter
plle,
Enlarged basesi 2500 mm diameter to 900 mm
diameter pile.
Enlarged bases; 3000 mm dlameter to 1200 mm
diameter plle.
Preparlng heads 900 mm diameter.
Preparing heads; 1200 mm diameter.
PIIJNGINSLIJARITS
Mlld steel renforcement to RS 4449.
Stralght bars, nomlnal slze not exceedlng
25 mm.
Straight bars, nominal slze: exceedlng
25 mm.
Obstructlons
m
t
t
h
m
nr
nr
nr
nr
40
87
46.3
150
20
27.3
42
87
42
64
PAGE
Number Item descrlptlon Unlt Quantlty Rate Amount
p
P Tf .ING ANCTI,I,ARTES
Timbcr o lcs crass-satianl re<
0.1's
-
-2s n3.
Pre-boring.
Number of pile extenslons.
Length of pile extensions each Length not
exceedlng 3 m.
Cutting off surplus lengths.
m
nr
m
m
h
nr
200
.50
75
25
10
5
0bstructions.
Pile tests, maintained loading wlth
various reactic.ns test Load: 75 t; to
workng pile.
EXAMPLE BILL OF OUANTITIES PAGES
P IER
Q4 15
Q44s
Q455
Q47s
Q700
Q81 1
PAGE TO
65
CESMM3 EXAMPLES
Q64
3
0653
Q673
Q70
0
TANKS
Amount
I
p
Unlt Ouantlty Rate
Number
Item descrlptlon
Interlocking stel plJ.es section
moduLus 1150 cmr/m.
Ur.U.t of pile extensions.
Length of pile extensions each Ienqth
not exceeding 3m.
Cuttlng off horizontal surplus lengths,
average depth 1..5m.
pTT,TNG
ANCTT,f.RrES.
Obstructions.
h
nr
m
150
300
20
220
66
PAGE
Number
Item descrlptlon Unlt Ouantlty Rate Amount
p
ROADS ND PVTNGS.
Sub-beses.
f I evihl e rod l"'ses and
surfaclng.
Granular material DTp Specfled type 1
depth 475 mm.
lfet-mix macadarn DTp Specifled cl-ause 808
depth 210 mm.
Dense bitumen macadam DTp Speclfied cl-ause
903 depth 60 mm.
Rol-l-ed asphalt DTp Specified clause 907
depth 40 mm.
Surface dressing depth 25 mm; nomj-nal 20 mm
coated chlppings.
3760
3750
37 60
3?60
3?60
971
48
27
9r'7
48
27
r426
387
387
t426
2't
Straight or curved to radlus exceedlng
12 m.
Curved to radlus not exceeding 12 m.
Quadrants
Precast concrete channels to BS 7263:
Part I figure 1 (h) straight or curved to
radius exceeding 12 m; 400 x 150 mm bed.
Precast concrete channel-s to BS 7263:
Part 1: figure I (h) curved to radius not
exceedlng 12 m, 400 x 1.50 mm bed.
Precast concrete channels to BS 7263:
Part L: figure 1(h) quadrant, 400 x 150 nm
bed.
T,ight duty
Davements.
Granular base depth 150 mm; DTp Specifled
type 1.
Hardcore base depth 300 mm.
In situ concrete grade C15 depth 150 mm.
Precast concrete fJ-ags to BS'1263: Part 1:
type D; thickness 63 mm.
Joint new concrete road to existing
concrete road.
EXAMPLE BILL OF OUANTITIES PAGES
NEIITON TO DINCHOPE ROAD
R118
R2L6
R232
R322
R341
R61 1
R61 2
R61 3
R64 1
R642
R64 3
R714
R127
R77 4
R78 3

R90 0
PAGE
67
CESMM3 EXAMPLES
SERVICE ROADS
Rt24
R17 0
R18 0
R414.1
R4r4.2
R443
R4BO
R52 4
R53 4
R65 1
R652
Number Item descrlptlon UnIt Quantlty Rate Amount
I p
BOADSIND-P]IXGS.
Sub-bases, flexibLe road bases and
surfacing.
Granular materlal DTp Speclfled type 2
depth 150 mm.
GeotextlLes; Georam, grade G2.
Additional depth of hardcore.
2
m
2
m
a3
2
m
2
m
2
m
2
m
m
m
m
m
103 9
103 9
380
103 9
t1 64
103 9
103 9
32L
47
r27
480
Cneret
pevements.
Carriageway slabs of DTp Specifled pavlng
qual-ity concrete depth 150 mm.
Carriageway sl-abs of DTp Speclfied pavlng
quality concrete depth 150 mm; lncllned at
an angle exceeding 10.
Steel fabric reinforcement to BS 4483
nomlnal mass 3 - 4 kq/n2; type 4252.
Waterproof membrane below concrete
pavements; 500 grade J.mpermeable plastlc
sheeting.
Jolnts in concrete oavernents.
Expansion
joints
depth 100 - 150 mmi as
detail C drawlng I31/5I at 5 m centres.
Contractlon
jolnts
depth 100 - 150 mm; as
detall- D drawing 1,3'l/5I aE 2,5 m centres.
Kerbs, channels and edglngs,
Precast concrete edglngs to BS 7263:
Part 1: figure 1 (m) straight or curved to
radius exceeding 12 m 200 x 200 mm
concrete ST1 bed and haunch.
Precast concrete edglngs to BS 7263:
Part 1: flgure 1 (m) curved to radius not
exceedlng L2 n; 200 x 200 mm concrete
STL bed and haunch.
68
PAGE
Number Item descrlptlon Unlt Quantlty Rate Amount
E
P
ROAI'IS ANN PVTNGS.
T,lgit dtv ovements.
Granular base DTp Speclfled type 2
depth 100 mm.
Granular base DTp Specifid type 2 depth
150 mm; lnclined at an angJ-e exceedlng
L0 to the horlzonta.
Precast concrete flags to BS 7263: Part I
type D depth 50 mm.
Precast concrete flags to BS 7263: Part 1
type D depth 50 mn; inclined at an angle
exceeding 10 to the horlzontal-.
2
m
2
m
2
m
2
m
840
31
330
390
EXAMPLE BILL OF OUANTITIES PAGES
SERVICE ROADS
R713
R714
R782. 1
R182
"2
PAGE
69
CESMM3 EXAMPLES
s 110
s120
s21 1
s2L4
s25 0
s28 1
s283
s310
s425
s4?1
s472
s481
s482
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
BUJIAACK.
Track foundatlon. bottom ballast,
crushed granite.
3
m
2
m
636
Track foundatlon, waterproof membranet
visQueen 1000 gauge. r250
Tklng up trck
lfelded trck on cncrete cIeepers. ftllv
rf a'.t' rnc n w
Bul-l head rail, plaln track.
BulL head rail, turnouts.
Conductor rails.
Sundr1es, buffer stops, approximate weight
2.5 tonnes <f sueel- raii and Llmber
sleeper construction.
Sundrles, wheelstops.
nr
m
2000
4
4 000
nr 4
2
f,lftlno, ockino and slewlng.
BulI head rall track, Iength 20 m, maxlmum
distance of sl-ew 200 mm, maximum lift
100 m. NI 1
Supplyi ng.
FLat bottom rail, reference 113A, mass
56 kg,/m.
Sleepers, softwood tlmberl
2600 x 250 x 130 mm.
Sleepers, concrete 26O0 x 250 x 150 mm
type C2.
Fittings, chairs, type 4.
Fittings, base plates, type 3.
38
nr
nr
nr
nr
s04
2'l
1008
1008
70
PAGE
Number
Item descrlptlon Unlt Quantlty Rate Amount
p
RATT, TRACK.
Suoplyl ng.
Pandrol rall fastenlngs, type 7.
Plain ftsh plates, type 9.
Turnouts, type T4, drawing 27.
Dlamond crossings, type DCl drawlng 27.
Sundrles, buffer stops, type 82 approximate
welght 2.5 tonnes.
Sundrles, swltch heaters, type SH2.
nr
nr
nr
nr
nr
nr
m
m
nr
nr
nr
nr
nr
94
L2'l
4
2
4
6
3200
2000
500
4
2
10
4
6
Lavl ng fI at bottom ral l s.
Plaln track; rail reference J.134, mass
56 kg/m, flsh plated
Jolnls
on tlmber
sleepers.
Plaln track; ral1 reference 1134r mass
56 kg,/m, welded
Jolnts,
on concrete
sleepers.
Form curve ln plaln track, radlus
exceedlng 300 m, welded
Jolnts
on concrete
sleepers.
Turnouts type T4, drawlng 27, Iength
26.2 m, flsh plated joints on timer
sleepers.
Diamond crosslngs, type DCl. drawLng 21'
Iength 27.4 n, flsh plated
Jolnts
on tlmer
sleepers.
elded
Jolnts
by Qulck Thermlt process.
Sundrles buffer sops approxlmate
weight 2.5 ,tonnes.
Sundrles swltch heater.
EXAMPLE BILL OF OUANTITIES PAGES
s4 83
s4 84
s5 10
s520
s5B 1
s58 5
s621.1
s62L,2
s623
s624
s625
s627
s68 1
s685
PAGE
71
CESMM3 EXAMPLES
T112.1
,TLL2.2
TL32
T17 0
T232.I
1232.2
T252.1
"1252.2
Number Item descrlptlon Unlt Ouantlty Rate Amount
E p
FORTIFY TT'NNET, ANN OVFRFT,OW SIF'T
Tunnel e-cavatlon d'l ameter 2.5 m.
In rock; stralght.
In rock; curved, materlal to be used
as filllng.
3
m
a3
3
m
2
m
2
m
a3
2
m
2
m
2L80
520
280
4352
820
175
3 566
160
I
Shaft excavatlon diameEex 2.8 m ln rock;
stralght.
Excavated surfaces ln rock; volds fllled
with cement grout as Speciflcation cLause
r3't /1t7 .
In situ reinforced cast concrete primary
stralght tunnel linlng internal diameter
2.0 m; concrete as Specj.fj.catlon
clause 137 /F3.
In sltu relnforced concrete primary
curved tunnel llnlng lnternal dlameter
2.0 m; concrete as Specificatl-on clause
L3't /83.
In sltu straight linlng formwork flnlsh
grade T2 lnternal dlameter 2.0 m.
In situ curved llnfng formwork flnlsh
grade T2 lnternal dlameter 2.0 m.
72
PAGE TOT
EXAMPLE BILL OF OUANTITIES PAGES
"tL28,L
rL28.2
T180.1
TL80,2
T53 B
Ts? 1
T57 4
Item descrlptlon
Unit Gluantlty Rate Amount
I p
Number
tlork to be e'ecuted under compressed ai r
t garlge
Presstrre
not evceeding one bar.
Excavation stralght tunnel- dlameter
10.3 m In Group 5 materlaL.
Excavation straJ.ght tunnel diameter
10.3 m in Group 6 materlal.
Excavated surface Group 5 materials;
volds fil1ed with cement grout as
Specificatlon Clause L3'l /T1,'l .
Excavated surface in Group 6 material;
voids fil-Ied with cement grout as
Specification C1ause L37 /1I7.
Cast iron bol-ted segmenta tunnel lining
rlngs lnternal- diameter 9.5 m; nominal
wldth 450 mm comprlsing 16 segrments
maxlmum plece welght 110 kq l-36 bol_ts
and grummets and 2'12 washers.
Parall-el circumferentlal packlng for
preformed segmental tunnel linings
lnternal- dlameter 9.5 m;
bltumen impregnated fibreboard
thlckness I mm.
Leaf fibre cauJ.king for preformed
segmentaL tunnel- Iinings internaL dlameter
9.5 m.
DVFRSTON TTINNE,.
nr
nr
2
m
m
3
m
3
m
2
m
4 1000
8800
15800
3400
133 0
1,329
51500
L-.
PAGE
73
CESMM3 EXAMPLES
1332
T352
TB11
TB3 1
T832
TB3 4
TB3 5
T83 6
T84 0
Unlt Ouantlty Rate Amount
I p
Number Item descrlptlon
FOREFY TUNNET, ANn OVERFT,OI/ SIIAFT
rectanoular 3.2 - 2-4 m.
Cast concrete size 2.'15 x 1.95 m;
concrete as Speclflcatlon clause 137,/F3.
Formwork finlsh Grade T1 size 2.75 x
1.95 m.
Srrpport and stal'i I i zatlon.
Rock bolts lmpact expanding mechanical
55 mm diameter with 30 mm square shank
maximum length 5 m.
Pessure grouting.
Sets of drllllng and grouting plant.
Drllllng and flushlng dlameter 50 mm
length5-10m.
Re-drilllng and fLushing holes length
5-10m.
InJection of cement grout as Speciflcatlon
clause 13?/T801.
Face packers.
Forward probing J-ength 10 - 15 m.
m
t
m
3
m
2
m
nr
nr
m
130
615
108
1 080
540
B5
480
1
180
74
PAGE
Number Item descriptlon Unit Quantty Rate Amount
p
RRTCR!IORK. BT,OCKWORK ANn MASONRY.
Cornmon briekwork to RS 3921: stretcher
bond, flush pointed mortar tvpe M2.
fOZ'.5 mm nominal thickness vertlcal
stralght wal-1s; cavlty constructlon.
Columns and plers, cross-sectional
dimensions 600 x 600 mm.
Anc lar es
Damp proof courses; width 100 mm to
BS 743 type D.
Damp proof courses; width 225 mm to
BS 743 type D.
Concrete lnfill grade 1; thlckness 50 mm.
Fxing and ties; galvanised mild steel-
in accordance with Specification
cl-ause 5/27.
Bullt-in pipes and ducts
area not exceeding 0.05
cro ss -s ect i on a l-
2
m.
Built-in pipes and ducts cross-sectlonal-
area O .10 mz.
Facing brickwork.
Plowden Red facings as Specifiction
clause 5/29.
102.5 mm nomlnal thi-ckness vertical-
straight wall-; stretcher bond flush
pointed, mortar type M3 cavity
construct ion .
Surface featrrres.
Brick on edge coplng.
Special sill as detail D drawing I31/91.
*2
m
m
m
m
2
2
m
NI
nr
m
m
m
287
43
150
l1
31
304
69
6
321
143
31
EXAMPLE BILL OF OUANTITIES PAGES
u111
u1 60
uI82.l
uL82.2
ut 85
U1B6
U1B7
u188
U2IL
v21I.r
u217 .2
PAGE TOT
75
CESMM3 EXAMPLES
u282
U2B7
U2B 8
u33 3
u33 4
u37 1
u37 5
U3B3
u38 4
u4t 1.1
usrt.2
u482.r
o482.2
Number Item descrlption Unlt Quantlty Rate Amount
E
P
BRTCKVORK. RT,OCKVIORK ND MASONRY.
Rrickwork anci l ari es.
Damp proof coursesi width 100 mm to
BS
'?43
type D.
Bullt-ln pipes and ducts
area not exceeding 0.05
cross-sectlonal
2
m
Built-n pipes and ducts cross-sectional
area 0.10 m'.
Rnoineering brckwork class R to S 3921,
stretcher bond flush pointed mortar
type M4.
450 mm nominal- thlckness battered stralght
wall.
450 mm nominal thickness battered curved
walI.
Bullnosed copings
BuJ.Inosed corbels.
Movement
Jolnt;
25 mm bitumen impregnated
fibreboard, mean wldth 450 mm wlth
plastljoint seal-er both sides.
Bond to existlng work.
m
nr
nr
2
m
2
m
m
m
m
2
m
2
m
2
m
m
m
187
69
6
8?
184
41
83
27
L4
203
t2'l
83
46
VertlcaL l00 mm nominal thlckness
stralght wall.
Vertical 140 mm nominal thickness
straight wall.
Damp proof courses; width 100 mm to
BS 743 type D.
Damp proof courses; width 140 mm to
BS 743 type D.
76
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
u5l- 1
u582
u587
u73 5
u77r
u78 6
u787
u799
Number Item desctlpton Unlt Quantlty Rate Amount
p
RTCKIIORK. F,OCKVIORK AND MASONRY.
Ilense concrete hockwork. solld block to
BS 6073, stretcher bond. flush pointed
^7:7 f rr M1
Vertlcal 140 mm nominal thickness stralght
waLl.
Damp proof coursesi wldth 140 mm to BS 743
type D.
Bullt-in pipes and ducts
area not exceedlng 0.05
cross-sectlonal
2
m.
shlr mesonrv
portnd
stone rubbed
flnlsh Speciflcation clause 5/40 mortar
type M2.
300 mm nonlnal thlckness vertLcal faclng
to concrete flush pointed.
Surface features; rounded coplngs
1200 x 600 mm as drawing L37/9L.
ncillarles flxlngs and tles; Alleyslots
at 1500 mm centres.
AnciLlarles built-ln plpes and ducts
cross-sectl-onal area 0.025
-
0.25 m'.
BoLlards diameter 600 mm height 900 mm as
drawng L37 /93.
^2
m
nr
2
m
m
m
nr
nr
83
27
4L
4387
r236
4 38?
45
24
L-.
PAGE
77
CESMM3 EXAMPLES
vl- 13
v116
Vl1B
v313
v31 6
V31B
v326
v533
v53 4
v5 63
v566
v633
v63 6
Unlt Quantlty Rate Amount
E p
Item descrlptlon Number
Zinc rich prlmer paint on metaL surfaces
othr than mctal sectlons and plpework
lnclined at an angJ-e exceeding 60' to' the
horizontal; in one coat.
Zin'c rlch prJ-mer paint on metal surfaces
other than metaL sectlons and pipework
width not exceeding 300 mlir; in one coat.
Zinc rich prlmer paint on metaf surfaces
other than metal- sectlons and plpework
lsolated groups of surfaces; 300 x 200 mm
inspection covers and frames in one coat.
OiI peint in three cots
On metal surfaces other than metal
sections and pipework; incllned at an
angle exceedlng 60' to the horizontal.
On metal surfaces other than metal
sections and pipework of width not
exceeding 300 mm.
On metal surfaces other than metal
sectlons and plpework isofated groups of
surfaces; 300 x 200 mm inspectlon covers
and frames,
Timber surfaces of width not exceedJ.ng
300 mm.
,PAINTING
Emulslon palnt ln three coats.
Smooth concrete surfaces incLined at an
angle exceeding 60' to the horizontal.
Smooth concrete soffit and lower
surfaces inclined at an angJ-e not,
exceedlng 60' to the horlzontal.
Brlckwork and blockwork surfaces
Inclined at an angle exceedlng 60' to the
horizontal.
Brlckwork and blockwork surfaces of
width not exceeding 300 mm.
Cement palnt on smooth concrete surfaces
lnclined at an angle exceeding 60' o the
horj.zontal; in one coat.
Cement paint on smooth concrete surfaces
of width not exceeding 300 mm; in
one coat.
nr
m
m
m
2
m
m
2
m
41
91
1,4
47
91
I4
14
481
326
3 867
187
2'l
L4
78
PAGE
Number
Item descrlptlon Unlt Quantlty Rate Amount
I p
SAI.BPBAO&ING
Damp prooflng, waterproof sheetlng to
upper surfaces incl-ined at an angle not
exceedlng 30 to the horizontal; polythene
to BS 3012 in one layer thickness 5 mm.
Tanking, asphaJ.t to upper surfaces
lncl-lned at an angle not exceeding 30' to
the horizontal; mastic asphalt to BS 1097
in one coatlng thlckness 25 mm.
Tanking, asphalt to surfaces lncllned at
an angJ-e exceedlng 60' to the horlzontal;
mastic asphalt to BS 1097 In one coaIng
thickness 25 mm.
Rooflng asphalt upper surfaces lncLlned
at an angle not exceedlng 30' to the
horlzontal-i mastlc asphalt to BS 988 in
two coatings total thlckness 25 mm
lncludlng heavy gauge poJ-ythene Isolating
membrane non-stalning rooflng felt to
BS 74? type 1C expanded polystyrene
thickness 25 mm and concrete grade 10
screened average thickness 75 mm.
Protective layer sand and cement screed
type A thickness 25 mm upper surfaces
lncllned at an angJ-e not exceeding 30' to
the horizontal.
2
m
2
m
2
m
m
2
m
320
410
534
'126
410
EXAMPLE BILL OF OUANTITIES PAGES
GENERATOR HOUSE
w131
W2LL
!{213
f311
v44 1
PAGE
79
CESMM3 EXAMPLES
PUMP HOUSE
t3? 1
!lI373
371
Unlt Quantlty Rate Amount

p
Number Item descrlptlon
Proflled alumlnlum sheet to BS 4868
type A L mm thick ln one layer upper
surfaced lncl-ined at an angle not exceedlng
30' to the horizontal.
Proflled aluminium sheet to Bs 4868
tt/pe A 1 run thlck in one layer surfaces
Inclined at an angl-e exceedl-ng 60' to the
horizontal.
Waterproof sheetlng upper surfaces
lncllned at an angle not exceedj-ng 30'
to the horlzontal; corrugated plastic
translucent sheet to BS 4154 1.5 mm thick.
I/iIATRRPROOF'TNG
Roofng
2
m
2
m
2
m
463
t25
51
80
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
x1 13
x133
xl3 6
xr.63.1
xl91
x1 93
x1 98
Unit Quantlty Rate Amount
E
p
Item descrlptlon
Numbr
Timber post and rail fence helght 1.3 m,
to BS l'122 Part 7.
Concrete post and wire plastic coated
chain lLnk fence to BS 1722 Part I height
1.4 m concrete grade 10 foundations
450 x 450 x 450 mm deep.
Concrete pos and wlre anti-lntruder
chaln link fence to BS L'122 Part 10 height
2.9 m with cranked posts concrete grade
10 foundations 600 x 500 x ?50 mm deep.
T1mber close boarded fence hetght 1.4 m;
wlth concrete posts to BS 1755 Part 5
concrete grade 10 foundations on surface
lncllned at an angle exceedlng 10'
Chestnut pale fence helght 900 mm,' with
timber posts to BS 1122 Part 4.
MIld steel uncllmbable fence height
L.372 m; Lo BS L122 Part 9 concrete grade
10 foundatlons 450 x 450 x 450 mm deep.
Mlld steel crash barrler helght 600 mm
concrete STI foundatlons
300 x 300 x 450 mm deep.
MTSCET,,\ROUS WORK
F enFes
187
4?0
305
403
108
t 871
13
PAGE
81
CESMM3 EXAMPLES
x215
x235
x295
x331.1
x33r.2
x332.L
x332.2
x333. 1
x333 .2
x334.1
x334.2
Number Item descrlptlon Unlt Ouatty Rate Amount
E p
U,ISCEIJTNEQIS-UA8,.
GatFs and stlles
Tlmber fleld gate, 2 leaves, overall
rrldth 3.353 m hetght 1.143 m; ro BS 3470.
Metal fleld gate wldth 3.353 m helght
1.143 m; t,o BS 3470.
Entrance gate wldth 3.5 m hetght 1.4 mt
galvanl-sed mlld steel angle sections
ftlled ln wlth plastlc coated chain llnk
fencing as detall D drawlng L3'l/75.
nr
nr
nr
m
m
nr
nr
m
m
nr
nr
14
2
1
4'l
36
10
8
23
16
4
3
Iralnage to strrrctures hove cround
@.
Gutters; 100 mm dLamet.er
cutters; 150 run dLameter.
Gutter bends 90'; 100 mm diameter.
Gutter outletsi 150 mm dLameter.
Downplpes; 100 run dlameter.
Downpipes; 150 mn diameter
Swan necks,' 100 mm dlameter.
Shoes; 150 nun diameter.
82
PAGE
Numbcr
Item descrlptlon Unlt Quantlty Rate Amount
I p
MI.SCEIJTNEaIS-HOBI,.
Rock f i' I ed gabions.
Box gablon 1 x 1 x 2 mz 4 mm x 100 x 100 mm
galvanlsed wire mesh, excavated rock
grde GB1.
Box gabJ-on 1 x 1 x 2 mi 4 mm x 100 x 100 mm
galvanlsed wire mesh excavated rock
grade GBl.
Mattress gabion, thickness 150 mm,
4 mm x 100 x 100 mm galvanlsed wlre mesh,
excavated rock grade GB2.
nr
nr
2
m
21
45
50
EXAMPLE BILL OF OUANTITIES PAGES
x410.1
x4L0.2
x420
PAGE
83
CESMM3 EXAMPLES
NEI,ITON STREET
Y1 10
YT2I
vL23
Y13 0
Y13 1
yL32
YI42
Yt 51
YI52
Y15 3
Unlt Rate Amount
E
p
Number
EIXT ST TNG PR T CK SRVTIR NOMT NL__gLUE--6.0.0_MN
ovo.In.
Lateral-; bore not exceeding 150 run;
clayware.
Dead water mal-ni bore not exceedJ-ng
150 mm; cast lron.
CCTV Survey.
Removino Intrrrslons.
Pee'ia!,
Cleaning.
uoglno aterals wlth grout as
Sgeclfi catlon cl ause ?.21 .
Bore not exceedlng 300 mm.
U shaped; lnternal cross sectlonal
dimensions 350 mn x 200 mm.
F{lllno laterals wlth grout as
Soec fi catl on c ause 7.21.
Internal cross section dimensions
450 mm x 350 mm U-shaped."
@.
Area not exceeding 0.1 m2.
Area 0.1 - 0 ,25 m2 .
Area 0. 6 m2.
nr
m
nr
3
m
nr
nr
nr
nr
nr
5?
L2
2L
2
1
1
57
6
4
1
84
PAGE TO
Number Item descrlptlon Unlt Ouantlty Rate Amount
I p
EXTSTTNG RRTCK SEER NOMTNAT, STZR 600 rnm
ato.rD.
Stalil I I -tion of e-lstlng sewers.
Polntlng brlckwork with cement mortar.
Pointing pipe
Joints
under pressure wth
epoxy mortar.
2
m
2
m
nr
3
m
m
14
7
4
6
57
Evternal groutlng.
Number of holes.
Injectlon of cement grout as Speciftcation
clause 7.24.
Renovation of exsting sewers
Butt fuslon wel-ded HDPE type SDR 4,
t,hickness 4 mm, 500 mm minimum lnternal-
dl-ameter.
EXAMPLE BILL OF OUANTITIES PAGES
NEIITON STREET
Y2LO
Y290
Y23L
y232
Y31 1
PAGE
85
CESMM3 EXAMPLES
NEWTO STREET
Y333
Y334.l-
Y334.2
Y360
Y411 . I
vALr.2
Y4t 3
Unlt Amount
E p
Item descrlptlon Quantlty Rate Number
EXTSTTNG PRTCK SRWER NOMTNI, SIZF
1200 X 900 mm. EGG SHAPEh.
Renovtlon of existing sewers.
GLass reinforced pJ-astlc as Specificatlon
cLause 7.50, minimum internal cross
sectlon dlmensions 1050 x 750 mm.
Glass reinforced concrete, 15 mm thick'
internal cross section dlmensions
1050 x 750 mm, egg shaped.
Gl-ass reinforced concrete, 15 mm thick,
lnternal cross section dlmensions
1320 x 850 mm, curved to offset of
70 mm per metre.
Segmentel l lnlngs
Cement grout as SpecJ.flcation
clause 7.25.
nnulus ororrti ng.
T,aterals to renovated sewers.
Bore: not exceedlng 150 mm, to HDPE
sliplining, type SDR 17.
Bore: 150 - 300 mm, to ITDPE sliplinlng,
type SDR 17, regarded.
900 x 600 mm, egg shaped, to GRP
segmental llnlng, 15 mm thick.
Joi nt i ng.
m
m
m
m3
nr
nr
nr
45
38
10
10
2
3
1
86
PAGE
Number Item descrlptlon
Unlt Quantlty Rate Amount
e p
FXTSTTNc RRTCK SEIRR NOMTNAT. STZF:
'l
200 X 900 mm, EGG SHPE'I.
Renovtlon of e-istlng sewers.
Segmenta I {nngs.
G1ass reinforced plastic
as Specificatlon
clause 7,50, mlnimum internaL cross
sectlon dimensions 1050 x 750 mm.
Glass reinforced concrete, 15 mm thick.
lnternal- cross section dlmensions
1050 x ?50 mm, egg shaped.
GLass reinforced concrete, 15 mm thlck,
Internal cross sectlon dimensions
1320 x 850 mm, curved to offset of
70 mm per metre.
nnul us orouti ngr.
Cement grout as Specification
clause 7.25.
m
m
m
m3
nr
nr
nr
45
38
2
10
10
3
1
Lterals to renoveted sewrs
Joi nt i ng
Bore: not exceeding 150 mm, to HDPE
slipJ-ining, type SDR 17.
Bore: 150
- 300 mm, to HDPE sIlpllnlng,
type SDR 17, regarded.
900 x 600 mm, egg shaped, to GRP
segmental lInlng, 15 mm thlck.
EXAMPLE BILL OF OUANTITIES PAGES
NE!TON STREET
Y333
Y334.1
Y334.2
Y3 60
Y411 . 1
YALL.2
Y4 13
PAGE
87
CESMM3 EXAMPLES
NEWTON STREET
Y42l .l
v42r,2
Y422
Y423
Y625
Y657
Y653
Amount
E
p
Unlt Quantlty Rate
Item descrlPtlon
Number
RXTSTTNG RRfCK SFVER NOMTNAf. STZR
1200 v 900 mm, FGG St{APEfi.
Flap yaves.
Remove exlstlng; nominal diameter 225 mm'
Remove existing; nomLnal dlameter 300 mm'
Replace existing; nominal diameter 225 mm'
New; HoLdwater cataLogue reference
918;
nominal dl-ameter 300 mm.
New manholes.
Brlck wlth backdrop type 14, heavy duty
cover and framei dePth 3 - 3.5 m'
Precast concreLe tyPe 2Br heavy duty cover
and frame; dePth 7'5 m.
Precast concrete Lype 2C, heavy duty cover
and frame; dePth 2 -
2.5 m.
nr
nr
nr
nr
nr
nr
nr
88
PAGE
EXAMPLE BILL OF OUANTITIES PAGES
VTESTFIELD ROAD
v5r2
Y522
Y542
Y562
Number
Item descrlptlon Unlt Qantlty Rate Amount
I
P
vr,vEs sv r 7-32
NXTSTTNG CST TRON MINS NOMTNI. ROREI NOT
FXCFTEI'TNG 200-300 mn.
Cleanlng.
Removing lntrusions.
CCTV Survey.
Epoxy Ilnlng as Speclficatlon
clause 263.0'l .
m
nr
m
m
60
t5
60
60
L-.
PAGE
89
CESMM3 EXAMPLES
NEVTON STREET
Number Item descrlptlon Unlt Quantlty Rate Amount
I
p
FXTSTTNG FRTCK SRhIRR NOMTNAT. STZE
1200 v 900 mm, FIGG StlAPPfi.
F-l,st i na manholes
ll-rrnnna :c r:ui aa )t la
Depth 2 -
2.5 n lncludlng removJ-ng cover
sIab, breaklng back shaft and backfllling
with pulverised fuel ash.
Depth 5.5 m incl-uding removlng cover sJ.ab,
breaklng shaft and backfilJ.Ing with
pulverlsed fuel ash.
nr
nr
nr
h
h
h
1
t
1
10
10
20
Itlork to benchlng and lnverts, as
drawlng 27lG incLuding bradlng out,
re-haunching and dealing with flows.
Tnterrupt i ons ,
Prepration of existing sev'rers.
Stabillzatlon of existing sewers.
Renovtion of exlstlno sewers
Segmental- Ilnings.
Y713
v1r7
Y'|20
Y810
Y82 0
Y833
90
PAGE TOT
Number
Item descrlptlon
Unlt Ouantty Rate Amount
p
RARTHVORKS.
(measred ln accordance with cLass E)
m
m
m
nt
m
2
m
fn
m
22
36
48
108
18
20
18
15
CONCRETE.
(measured
in accordance wlth classes F-H)
METT, CT,ANNTNG.
(measured
in accordance with class N)
trRrCKtlORK, RIOCKIORK ND MASONRY.
(measured
In accordance wlth class U)
CARPENTRY ANN JOINRRY.
Sr.rn softrrood strrcturl end carcssi ng
iJmhar :c ana^i fi+{
^l
"-^ , n?
In walls and partltlons; 50 x 38 mm.
In wa1ls and partltions; ?5 x 50 mm.
In pltched roofs; 75 x 50 mm,
In pitched roofs; 100 x 50 mm,
In pitched roofs; 150 x 25 mm.
Chipboard tongued and grqoved floor
boarding 19 mm thick.
Ml scel I eneous lol nery.
hlrought softwood skirtings, flnlshed slze
150 x 19 mm, In trvo cross section shapes.
frouqht softwood archltraves, flnished slze
46 x L9 mm, 1n two cross sectlon shapes.
EXAMPLE BILL OF OUANTITIES PAGES
GATE HOUSE
E***
F-Hr
* *
N210
u***
ZIT2.L
zII2..2
7,LI4.I
zLt4.2
zrL4.3
z132
2151
zr52
PAGE TOT
91
CESMM3 EXAMPLES
2153. 1
2t53.2
zLs4
276I.L
zr6t.2
zr62
zL63
zl69
zt64
7.22I
2311.1
z3rr.2
2311.3
z3tt.4
z3r3.I
23t3.2
GATE HOUSE
Number Item descdptlon Unlt Quantlty Rate Amount
E
P
CARENTRY NN JOTNRRY.
Misce I aneous ioi nerv.
ltrought softwood beadlng, flnished size
25 x 12 mm.
Vrought softwood capping, finlshed slze
144 x 19 run.
l{rought softwood shelves complete wlh all
framlng and support, 300 x 12 mm as
Drawlng No C1lGHl003.
m
m
nr
nr
nr
nr
nr
nr
^2
nr
nr
nr
nr
nr
nr
I
2
6
1
1
2
I
1
1
20
1
I
1
2
t
2
Kl tchen un { ts as
rlurore rr
rnge
manufactured bv Kitchens elioht. nit ?
Stnley Tndustril Rstate. Cheedle Fulme
SK8 7JJ.
1000 x 600 mm base unit
1000 x 600 mm slnk unlt
500 x 600 mm walL unit.
2000 x 600 mm v',ork top
1500 x 500 mm sJ.ngle bowL and dralner
sink unlt.
Flbreboard notlce board 2 m x 1 m x 12 mm
thlck.
FibregJ-ass guilt, 150 mn thick, lald
betvreen ceillng
Jolsts.
glNfiov\s
. nooRs ANn Gf ,z rNG
.
filrouoht softwood w'|ndows as frwlng
cA/GH l06.
Overall- slze of opening 300 x 900 mm.
Overal-l slze of opening 1500 x 1000 mm.
Overall size of openlng 1500 x 2000 mm.
OveraJ.f sLze of opening 1900 x 2000 mm.
frought hardwood door set type 1A as
Drawing CA/CH/O7, kept clean for stalnlng,
size 900 x 1850 mm.
Vrought softwood door set type 18 as
Drawlng CA/GH/l1, slze 900 x 1850 mm.
92
PGE
Number Item descrlptlon Unlt Gluantlty Rate Amount
E p
VTNnOT^]S, I'OORS ANI' cr,ZTNc.
Trannnnaarr :c r:wi aa AL /eH /l\'1
Paj.r of steel butt hinges; ?5 x 50 mm.
Pair of steel butt hinges; 100 x 75 mm.
frSteptoe"
door closers, 140 x 22 mn,
149 x ?0 mm horlzontal mortice latch.
Handles; ref HI.
Ilandles; ref H2.
nr
nr
nr
nr
nr
nr
2
m
2
m
^2
nr
2
m
2
m
2
m
2
m
m
5
L
3
1
1
2
13
1
1
I
20
90
4
t2
3
GLAZTNG.
6 mm clear float glass, fixed hrith putty.
5mm patterned glass as Drawlng CA/Gll/06.
6 mrn Georgian wlred glass in vlsLon panels
130 x 850 mm flxed wlth wod beads.
6 mm mlrror, 600 x 600 mm Ith 4 No
drilled holes, fixed wlth dome head
mlrror screlvs.
STIRF'ACE F'TNTSI]ES T,TNTNGS Nf PRTTTTONS-
Tn sltu flnlshes, heds and backlnos
Sand and cement floor screed 38 mm thlck,
floated flnish.
lal I s
3 mm plaster veneer coat.
Sand and cement backing, 6 mm thick,
2 coa|. plaster 13 mm thlck.
2 coaL plaster-13 mm thick to surfaces not
exceedlng i00 mm wide.
.EXAMPLE
BILL OF OUANTITIES PAGES
GATE HOUSE
z34L.r
234t.2
2342
2343
2345.r
2345.2
2351.1
235r.2
2351.3
2355
Z4TT
z4t3.L
2413.2
24r3.3
z4t5
PAGE
93
CESMM3 EXAMPLES
GATE HOUSE
z42t.r
z42r.2
2423
z43r
2443.L
2443.2
2445
7,452
2480
Unlt Quantlty Rate Amount
E
p
Number
Item descrlptlon
suRFCE FTNTSHES. T'TNTNGS ANn PARTTTTONS.
Oarry tlles as manufctured by Owen
Rrothers of Vrevham, Cwyd.
150 x 150 x 16 mm thck to floors
Carpet tiles, Soporo ranoe as suPplied by
Kinosland Carpets, St lbans, llerts'
500 x 500 squares Lo floors.
fihte ceramlc tles as mnufactured hy
Owen Frothers of IIrevham. Cl wycl .
100 x 100 x 6 mm thick to walls.
V'|nyl sheet floor covernci
trblue
heavenrl
as supplled by Klngsland Caroets.
St lbans tlerts.
4 mm thick
Plasterboard dry llningrs to walls and
,tt."hed co l rrmn s .
12 mm thlck flxed wlth piaster dabs.
12 mm thlck, flxed with nails.
12 mm thlck, foll backed, flxed with
plaster dabs, to surfaces not exceedlng
300 mm wlde.
'r!fel-come
2000" suspended ceillng to a
600 x 600 mm qrid, 150 -
500 mm deep with
6 No
"Centurlan"
lntegral light fittlngs
each 300 x 1200 mm.
rrHogbenrr
standard slngle L-shaped ftC
cubicle partltlon comprlslng slde panel
and door complete wlth all flttlngs and
lronmongery.
T2
6
4
4
3
20
1
45
2l
2
m
2
m
2
m
2
m
2
m
2
m
m
2
m
nr
94
PAGE
Number Item descrlptlon UnIt Quantlty Rate Amount
E p
PIPED RUTT,NING SF:RVTCES.
Cold weter {nsta lat,|on.
Copper pipes L2 mm bore.
Coper plpes 18 mm bore.
Copper ploe fittings.
12 mm capiJ.lary bends.
12 mm capiJ-J-ary junctlons
and branches.
1B mm capillary bends.
19 mm capilJ.ary taper.
18 mm compression bends
18 mm compresslon
Junctions
and branches.
18 mm compresslon valves.
Overf low plpework i nstallatl on.
12 mm UPVC pipes.
12 mm UPVC sovent we'ded plpe fttlnos
Bends.
m
m
nr
nr
nr
nr
nr
nr
nr
m
nr
m
m
nr
nr
nr
nr
nr
25
t5
L2
I
10
2
6
I
2
3
6
25
15
1
1
1
1
1
Preformed pioework Insr'Iation 15 mm thlck
To plpe bore 12 mm.
To plpe bore 18 mm.
Rol I er pl ant and anc ll ari es
5L electrlc water boller as Specfication
clause 24.I5.
MouLded plastlc 50I storage tank.
Sanltary appl lances and flttinos as
Iyfordt s
riSl
mpli ci ty'r ranoe
WC suite wlth pan, cistern, flush plpe
and seat, cataLogue ref L64
BowL urlnal with exposed flxlng lugs,
cJ-stern, flush pipe, waste flttlng and
trap, catalogue ref 178.
fash hand basln wlth brackets, plllar
taps, vJaste outlet, plug and chaln, and
trap, catalogue ref 182.
EXAMPLE BILL OF OUANTITIES PAGES
GATE HOUSE
2511.1
25L1,2
z5L2.L
25L2.2
25t2.3
25t2.4
2512.5
2512.6
7,5L2.1
2511.3
2512.8
2513.1
2513.2
z52L
2524
2530.1
2530,2
2530.3
PAGE
95
CESMM3 EXAMPLES
z'llL
z7l3.L
27t3.2
2712.1
7,'172.2
2772.3
z'7'12.4
218l
7,1lL
2782.L
2782.2
7,782.3
2783
2784.1
2784.2
z'r82.3
v***
hl***
x***
GATE HOUSE
Rate Amount

p
Unlt Quantlty
Item descrlPtlon
Number
CAT,ED RUI,|TNG SERVTCES.
PVC Insulated, 3 core, 12 mm cables lald
or drawn in condults.
PVC, insulated, 3 core, L2 mm cables flxed
to surfaces.
TeJ-ephone cable.
Cable and conduit
final circuits.
Light Ing.
Heating and
Power '
Motor
Water heater.
Egulpment.
rrvent
a quIck" extract fan catalogue
ref 1I.3.
Flt.lic.
Swi tches.
Dtstributlon
board.
Light switches; one gang.
Llght switches; two gang.
Llght fittinqs.
Swltched potrer sockets
Slngle.
DoubIe.
Telephcjne sockets
PINSX.C.
(measured In accordance with class V)
!iATERPROOF'TNG.
(measured ln accordance wlth class W)
40
1
6
L2
L5
2
t
1
1
t
2
1
4
2
2
m
nr
m
m
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
nr
DRTNAGE TO STRUCTURFIS ABOVFI GROUNN.
(measured in accordance wlth class X)
96
PAGE

You might also like