You are on page 1of 2

MONITORS

DynaCHARGE 100 Series


The DynaCHARGE 100 series particulate monitoring systems offer a range of capability and functionality in single and multichannel
configurations. Both models are based on FilterSenses MICS (pronounced mix) platform.
DynaCHARGE PM 100 PRO
Highlights
High Performance and Rugged Construction
Widest Range of Features, Functions, and Approvals
The PM 100 PRO incorporates an advanced processor/display that provides a range of
value-added features for process control and EPA compliance. It is ultra-rugged for harsh
outdoors or it can be remote mounted.
Choice of sensing performance (any combination for multichannel)
Measurement

Highest precision/lowest levels (as low as 0.1mg/m3)


Most precise trending, calibrate for output in mg/m3, gr/cf

Monitoring

High precision/low levels (~1-5 mg/m3)


High resolution trending and EPA leak monitoring

Detection

Maintenance indication and leak/flow detection

On-screen trending (real-time, averaged, historical, and comparative)


Quickly understand process particulate flow and filter condition
Evaluate events on the spot (effective for EPA corrective actions rules)
Simplify conducting EPA response checks and gravimetric correlations
Comprehensive alarm management system
Data Historian (optional)
High-quality data, alarm, and event logging to internal flash
Real-time mirroring to SD card for redundancy and long-term archiving
EPA Quality Assurance (optional)
Set and record EPA quality assurance checks
DynaCHARGE PM 100 (enclosure window optional)
Highlights
Essential Features and Functions
Core FilterSense Advantages
The PM 100 provides reliable continuous particulate monitoring and leak/flow detection
along with a solid range of features, functions, and I/O via the MICS platform.

Prevent Emissions, Improve Operations...Our Edge Is Your Advantage

Particulate Monitoring
and Control Solutions
MONITORS
Model Comparison (some items are optional)
Universal Power
MICS Platform
Single and Distributed Enclosures
1

Processor/Display
Resolution (Minimum Detection)2

Range (Response Time)


Automatic Self Checks
On-Screen Strip Graphing
Output Averaging
Derived Output Variables
Alarming
Data Logging
EPA Quality Assurance
Channels (Configuration Based)
Analog and Digital I/O
Fieldbus Communications3
Environment
Construction
Area Classifications
Particulate Sensors
Temperature
Pressure

DynaCHARGE PM 100 PRO

DynaCHARGE PM 100

Single Only

Advanced/4.3" Color, Graphic


0.1 pA (as low as 0.1 mg/m3)
0.5 pA (~15 mg/m3)
5.0 pA (~510 mg/m3)
01000 mg/m3+ (<1 sec)
EPA Certifiable
With Historical Recall
Real-time and Avg (Simultaneous)

Alarm Management System


Historian with Redundancy
Yes
116 (or 32)
Up to 8 Each

-40F to 160F (-40C to 71C)


Harsh Process Duty
To Class I Div I
PS Type
-40F to 1600F (-40C to 871C)
Up to 2000 psi (137 bar)

Basic/2.7" Monochrome

0.5 pA (~15 mg/m3)


5.0 pA (~510 mg/m3)
01000 mg/m3+ (<1 sec)

Real-time or Avg

Basic
Basic

18 (or 16)
Up to 4 Each

-13F to 140F (-25C to 60C)


Industrial Duty
To Class II Div II
PS Type
-13F to 500F (-25C to 260C)
Up to 50 psi (3 bar)

Note1: 120-240 VAC or 24 VDC


Note2: Recommended Application: (0.1 pA Measurement), (0.5 pA Monitoring), (5.0 pA Detection)
Note3: Certified Fieldbus: Ethernet IP, DeviceNet, Modbus (TCP, RTU), Profibus (DPV1, V0, I/O), CanOpen, CC-Link, EtherCAT

Installation Example

DynaCHARGE PM 100 PRO