You are on page 1of 7

Story

BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE

Point

Load

12
12
12
12
12
12
12
12
12
12
12
12
12

SDL
SDLPEX
SDLNEX
SDLNEY
SDLPEY
SDPEX
SDNEX
SDNEY
SDPEY
SD1PEX
SD1NEX
SD1PEY
SD1NEY

FX

FY

-1.91
-2.36
-1.48
-1.87
-1.96
-2.34
-1.16
-1.69
-1.81
-2.53
-1.35
-2
-1.88

FZ

-0.36
-0.37
-0.35
0.31
-1.03
-0.35
-0.32
0.56
-1.23
-0.38
-0.36
-1.27
0.52

MX

26.08
27.31
24.62
24.05
27.88
24.84
21.25
20.49
25.6
27.4
23.81
28.16
23.05

MY

1.037 -4.473
1.085 -10.588
1.023
1.678
-1.654 -4.066
3.762 -4.844
1.035 -12.138
0.951
4.218
-2.617 -3.441
4.603 -4.479
1.145 -12.578
1.062
3.778
4.714 -4.919
-2.507 -3.881

MZ

0.025
0.038
0.007
0.056
-0.011
0.036
-0.005
0.06
-0.029
0.038
-0.003
-0.027
0.062

Footing F1
Shear Check

Unit - Kip-ft (KN-m)


Node
No.
12
12
12
12
12
12
12
12
12
12
12
12
12

Pu

Load

Kip
26.08
27.31
24.62
24.05
27.88
24.84
21.25
20.49
25.6
27.4
23.81
28.16
23.05

case
SDL
SDLPEX
SDLNEX
SDLNEY
SDLPEY
SDPEX
SDNEX
SDNEY
SDPEY
SD1PEX
SD1NEX
SD1PEY
SD1NEY

ALLOWABLE BEARING CAPACITY


Pu+5% Pu

Moment (kip-ft)
Mx
My

Kip
28.688
30.041
27.082
26.455
30.668
27.324
23.375
22.539
28.16
30.14
26.191
30.976
25.355

MAX LOAD

1.037
1.085
1.023
-1.654
3.762
1.035
0.951
-2.617
4.603
1.145
1.062
4.714
-2.507

30.976

Kips

-4.473
-10.588
1.678
-4.066
-4.844
-12.138
4.218
-3.441
-4.479
-12.578
3.778
-4.919
-3.881

B.C

Sq.

ksf
2.088
2.777
2.777
2.777
2.777
2.777
2.777
2.777
2.777
2.777
2.777
2.777
2.777

Side
3.707
3.289
3.123
3.086
3.323
3.137
2.901
2.849
3.184
3.294
3.071
3.340
3.022

2.088

Ksf

Column
CL
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

CB
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67

100

Kpa
Area

Area

q max

q min

Check

Req.
13.739464
10.817633
9.7521102
9.5263302
11.043413
9.8392533
8.4172356
8.1161957
10.140293
10.853283
9.4312649
11.154323
9.130225

Pro.

ksf
1.6835952
2.0842415
1.4540102
1.5991837
1.9927143
2.0356429
1.4105748
1.4474796
1.9134932
2.2015408
1.5286531
2.0794626
1.5976633

ksf
1.0486
0.7768
1.1252
0.9203
0.928
0.5666
0.8156
0.6991
0.7684
0.6689
0.9657
0.8706
0.8171

OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK

Footing

Beta
0
0
0
0
0
0
0
0
0
0
0
0
0

FL
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25
5.25

B
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92
3.92

FB
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00

21
21
21
21
21
21
21
21
21
21
21
21
21

137.7812 KN
MAX

MAXIMUM PRESSURE ULTIMATE PRESSURE =


FOOTING CANTILEVER LENGTH =
MOMENT =
As =

1.625

4.9414271604
0.0791895

FOOTING THICKNESS
VALUE OF F'c
VALUE OF D WILL BE

sq. in
1.5

3.742619 Ksf
ft

179.19662 KN/m2
0.4953

2.2015408 Ksf
105.40977 KN/m2

K-FT
Greater than As(min) (Therefore As Governs)
ft

3000

psi

16

in

457.1777 mm
21

BOTTOM COVER

in

50.798 mm

Mpa

406.380 mm

CHECK FOR ONE WAY SHEAR

CHECK FOR TWO WAY SHEAR(PUNCHING SHEAR)


Bo

128

in

3.25

Phi Vc =

17.877664 Kips

79.5199 KN

Phi Vc =

381.41 Kips

1696.5

KN

SHEAR =

6.0817565 Kips

27.0517 KN

SHEAR =

30.976 Kips

137.8

KN

Since

Phi Vc

is Greater Than SHEAR

FOOTING IS SAFE IN ONE WAY SHEAR

Since

Footing F1
Shear Check

Phi Vc is Greater Than SHEAR

FOOTING IS SAFE IN TWO WAY SHEAR(PUNCHING SHEAR

Footing F1
Shear Check

Ecentricity Ecentricity Kern Limit Kernlimit ex In Kern ey in Kern


ex
ey
Ckx
cky
Limit
Limit
0.155919 0.036148
0.875 0.666667
Yes
Yes
0.352452 0.036117
0.875 0.666667
Yes
Yes
0.06196 0.037774
0.875 0.666667
Yes
Yes
0.153695 0.062521
0.875 0.666667
Yes
Yes
0.15795 0.122669
0.875 0.666667
Yes
Yes
0.444225 0.037879
0.875 0.666667
Yes
Yes
0.180449 0.040684
0.875 0.666667
Yes
Yes
0.152669
0.11611
0.875 0.666667
Yes
Yes
0.159055 0.163459
0.875 0.666667
Yes
Yes
0.417319 0.037989
0.875 0.666667
Yes
Yes
0.144248 0.040548
0.875 0.666667
Yes
Yes
0.1588 0.152182
0.875 0.666667
Yes
Yes
0.153066 0.098876
0.875 0.666667
Yes
Yes

emax (x)
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

emax (y)
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

ex within

ey within

emax (x)

emax (y)

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

eL / L f
0.029699
0.067134
0.011802
0.029275
0.030086
0.084614
0.034371
0.02908
0.030296
0.079489
0.027476
0.030248
0.029156

eB / B f
0.009037
0.009029
0.009444
0.01563
0.030667
0.00947
0.010171
0.029027
0.040865
0.009497
0.010137
0.038046
0.024719

C3 From

Qmax

Table

C3*(P/A)
0
0
0
0
0
0
0
0
0
0
0
0
0

Check

Footing F1
Shear Check

Story
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE
BASE

Point
901
901
901
901
901
901
901
901
901

Load
SDL
SDLEX
SDLEX2
SDLEY
SDLEY2
SDEX
SDEX2
SDEY
SDEY2

FX

FY
2.52
1.54
3.56
1.4
3.71
1.03
3.72
0.84
3.91

FZ
-1.3
-0.94
-1.67
-3.73
1.12
-0.71
-1.68
-4.43
2.04

MX
194.23
187.68
194.6
186.36
195.93
159.09
168.31
157.32
170.07

7.051
3.834
9.908
26.721
-12.979
1.649
9.745
32.151
-20.757

MY

MZ
6.33
-0.964
14.059
1.866
11.228
-3.53
16.49
0.242
12.718

1.36
1.191
1.409
1.677
0.923
0.864
1.153
1.511
0.506

Umar FarooqPART 2 .. ISOLATED FOOTING SHEAR CHECK


NOW JAB PART 1 MEIN JO FOOTING SIZE FINALIZE KIYE HAIN MEANS qmax
less than Allowable bearing capacity aa gaya hai then jo jo footing sizes same
aye hain unkey Point labels ko alag copy karein aur us mein MaximumPu jis
Point label mein hai uskey Reactions ko copy karlein for Example suppose 4
columns hain means 4 point labels tu in 4 labels mein sey 3 labels mein aik hi
footing size aaa jata hai aur in 3 labels mein sey jo bhi maximum PU ata hai
us point labels key reactions ko select karlo
then open THIS SHEAR EXCEL SHEET AND THERE ARE TWO TABS IN IT
IN TAB(1) I.E SERVICE LOADS yahan woh label key reactions paste karoo jiska
PU subsey ziada aya tha
IN TAB(2) i.e. pRESSURE CHECK , IN THIS SHEET , PUT VALUE OF ALLOWABLE
BEARING CAPACITY , PUT CL , CB , BETA , FL , FB THEN FOOTING THICKNESS ,
VALUE OF F'c , BOTTOM COVER AND THEN CHECK BOXES
IF FOOTING NOT SAFE THEN CHANGE FOOTING THICKNESS , FOOTING MUST
BE SAFE IN BOTH ONE WAY AND TWO PUNCHING SHEAR
PART 2 SHEET END , NOW ONLY FOOTING DESIGN REH GAYA HAI WOH MEIN
BATAONGA INSHAALLAH PART 3 MEIN
JO QUESTIONS HAIN PLEASE ASK
February 9, 2013 at 11:38amLike1
Arshad ShehzadUmar Farooqaik general sa sawal hy k
footings to service loads k lye design hoti hy to Pu aur 5%Pu k ultimate loads
q shamil kye jaty hn??
February 9, 2013 at 11:44amLike
Umar FarooqArshad Shehzadbrother Service combos mein Sevice +
seismic bhi nclude hota hai means seismic + dead+live include hota hai
means for seismic cases , load ko 5 % increase kia jata hai
February 9, 2013 at 1:20pmLike1
Har OOncheck kar ky pochon ga questions to zaror hon gay

You might also like