1.3
1.0
For Top bars (Min. 300mm concrete Cast below), ACI 12.2.4
For others, ACI 12.2.4
1.0
ACI 12.2.2
43.9 d
=
For Top bars (Min. 300mm concrete Cast below), ACI 12.2.4
33.8 d
=
For others, ACI 12.2.4
Ld for Bars dia > 20 mm :
Ld=
ACI 12.2.2
54.3 d
=
For Top bars (Min. 300mm concrete Cast below), ACI 12.2.4
41.8 d
=
For others, ACI 12.2.4
b- Compression Development Length Calculations According ACI 12.3:
Ldc = max of
= 17.0 d
ACI 12.3.2
= 17.0 d
ACI 12.5.2
and shall not be less than the larger of 8db and 150 mm, ACI 12.5.1
= 29.8 d
ACI 12.16.1
= 0.0 d
ACI 12.16.1
10
12
14
16
18
20
25
28
32
Ld
338
406
473
541
609
676
1044
1169
1336
Hook
170
204
239
273
307
341
426
477
545
Ldh
Class A
Splice = Ld
Class B
Splice =
1.3Ld
338
406
473
541
609
676
1044
1169
1336
439
527
615
703
791
879
1357
1520
1737
Class B
Splice= 1.3Ld
439
527
615
703
791
879
1357
1520
1737
571
686
800
914
1028
1143
1764
1976
2258
Ldc
SPLICE
200
217
253
289
325
361
452
506
578
298
358
417
477
537
596
746
835
954