You are on page 1of 1

Question 8

Ammonium nitrate fertilizer production unit

V-6
NEUTRALIZER
10-4" Dia 9-8" Sidewall
DP Atmosphere
DT 270 oF

V-5
SCRUBBER
7-6" Dia 20-8" Sidewall
Stack height 14-6"
DP Atmosphere

V-7
RUNDOWN TANK
14-0" Dia 7-3" Sidewall
DP Atmosphere
DT 250 oF

P-101
83% AMMONIUM NITRATE PUMP
20 GPM @ 80 oF
Rated head: 80 PSI

P-102
83% AMMONIUM NITRATE PUMP
5 GPM @ 80 oF
Rated head: 75 PSI

P-104
SCRUBBER RECIRCULATION PUMP
1500 GPM @ 225 oF
Rated head: 10 PSI

P-103
SCRUBBER RECIRCULATION PUMP
1500 GPM @ 225 oF
Rated head: 10 PSI

P-105
NITRIC ACID METERING PUMP
2.4 GPM @ 70 oF
Rated head: 55 PSI

Make-up water
Dwg. 10537
FIR
29

FT
29
M

AIC
28
Ammonium nitrate
Dwg. 18546

V-6
P
MW
24"

FFC

Median

AY
28

23

FV
25

pH

AIT
28a

FIC
25

pH

FT
23

FV
23

FT
25

LIC

AIT
28b

35
LV
35

pH
FOUNDATION Fieldbus

AIT
28c

LT
35

Nitric acid supply


Dwg. 12051

Lead/Lag

FI

IAS

FY
23

LIC
26

FE
24

Ammonia /
off-gas
Dwg. 10927

Mixer
V-5

pH

AIT
33

FT
24
FIR
22

H
L

H
L

FT
22

FIR
24

V-7

AIC
33

2"
insul

LG
21
Condensate
Dwg. 19320

LG
31

LT
26

30 PSI steam
Dwg. 19320

AIR
33
AIR
32

ST

LIR
30
H
L

FIR

TV
27

FIC

37

LT
30

TT
27

36

pH

AIT
32

FT
37
Ammonia vapor
Dwg. 10385

FT
36

/P

FV
36

TY
27
Set @ 10 PSI
TIC
27

VFD

P-101

file i0008r

P-102

P-103

P-104

P-105

You might also like