INVERTER SV550iP5A

55kW (75HP) 380-480V UL Open Type

Conduit hole for control


terminal
Conduit hole for power
terminal
Trade Size of the Conduit

22(0.86) mm (inch)
51(2.00)

16(1/2)
41(3/2)
Note: Choose the proper size of the Locknut, Bushing corresponding to trade size of the Conduit in use.

Easy Start
When pushing STOPkey for 2~3 seconds in case inverter turns on, the inverter turns into Easy Start modewith FWD, REV, and
STOP command. SHIFT/ESCcan return it to previous mode.
Control method: V/F
Control frequency: Jog
380-480V Class 55kW (75HP)

Note 1) Rated capacity (v 3VI) is based on 220V for 200V class and 460V for 400V class. 2) Indicates the maximum applicable
capacity when using a 4-Pole LS motor.
3) Maximum output voltage will not exceed the input voltage. An output voltage less than the input voltage may be programmed if
necessary.
4) IP20/UL Type1 with optional conduit, it can be modified to UL Type1.

Dynamic Braking
UL Type

Motor rating

400V class

DB Unit

45~55 kW (60~75 HP)

SV550DBU-4U

External DB Resistor
Applied motor
Capacity (kW/HP)

400V

55/75

Operating rate
100% Braking Torque
(ED/Continuos Braking Time)
[ohm]

10% / 6sec

11.4

[W]

9600

MCCB and MC

400 V
AC Input Fuse

400 V

Q&A
Q: M7 is Forward Run command (FX). Now I want to do M7 is Reverse Run command (RX). How can I do it,please tell
me
A: Since M8 has the value of RX, you have to change I/O-26 first as another value which you are not using.
The parameters cannot be overlapped.
Then please set M7 as reverse run.
Q: Sometimes inverter shows fault Low voltage again sometimes its ok again shows same fault. my motor is also
shows good. How can I remove this fault?

A: First, Check your inverter Vdc. If your inverter Vdc level is under these voltage (200V Class : 180Vdc / 400V Class
360Vdc), Low voltage can occurs.
Second, Check M/C in inverter. M/C in inverter has trouble, Low voltage can occur. In case of this situation, you have
to change the PCB.
Q: Inverter shows fault Out Phase Open how can I solve this problem? inverter remedy says output (u v w) phase is
open how can I this fault.
A: Out Phase Open are shown when one or more of the output (U, V, W) phase is open or has high difference in
current between each cable.
Check motor if it is okay, and check each U,V,W's current to see if it is sending out different level of current and check
cable. If those two does not have any problem, then our iS5's current measuring component might have problem.