You are on page 1of 22
EERECO [EGYPTIAN FOR ELECTRICAL BARTHING e EERECO EGYPTIAN FOR ELECTRICAL EARTHING YOU ARE PROTECTED 8 Mansour Maran St, in front of Giza court, Giza Spal - ASW Seal Loans plal- Ghee sgaria ELA, Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail: egy.earthing@gmail.com e EERECO EGYPTIAN FOR ELECTRICAL EARTHING. BUSINESS: Company profile Typical customers & previous works TECHNOLOGY: About earthing The importance of reliable earthing Earthing system classification The hazards of unqualified earthing system Characteristics of a good Earthing System The key factors that impact earthing system Lightning protection system Exothermic welding COMPONENTS: Earth rods Earth rod clamps Earth inspection pits Distribution earth bars Bonds and clamps Earth conductors Exothermic weld 8 Mansour Mabran St,, in front of Giza court, Giza Sjoodl~ LNA Bygall Sou plal- Glee sgenie yl A Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com e@ EERECO EGYPTIAN FOR ELECTRICAL EARTHING. Company profile Egyptian for Electrical Earthing co. EERECO, which integrates design, installation and service, is a high- tech enterprise specialized in the field of Earthing and Lightening Protection systems. The products range of EERECO includes earth rods, earth conductors, ESE lightning rods, connectors and clamps, distribution earth bars, exothermic welding and inspection manholes. These products have been widely used in the earthing works (such as anti-static earthing, protective earthing, and functional earthing) of transmission and transformation facilities, communications bases, airports, railways, data centers, and petrochemicals and other sectors, with considerable market potential and good prospects for development. With our business philosophy "high quality, inexpensive, quality service", we obtain a vast customer base and become the top service provider of many famous enterprises. The Earthing and Lightning Protection systems follow International Standards like IEEE, IEC and BS and are acknowledged by leading Electrical Distributors and Consultants. EERECO Design services, site surveys and analysis include: 1) Lightning protection Solutions: 2) Soil resistivity surveys: — Team of experienced engineers — Experienced surveyors — Risk assessment complying to latest — Key to creating effective earthing system standards — Multiple readings taken to ensure safe and accurate designs 3) Analysis & earthing design 4) Earth resistance testing = Engineered designs to meet client = Verification of earthing design through specifications measurement = Range of detailed reports to clients — Experienced team of engineers with full requirements understanding of electrode testing 1) Earthing & lightning protection solutions There are many benefits of coming to EERECO for earthing and light 1g protection: = Specialist advice from our fully qualified technical team, which focuses on earthing and lightning protection — Designs that comply with all relevant standards - national and international ~ Our responsibility for providing a design that is safe — Experience and the software to provide an ‘optimum’ design - one that doesn’t use more material than is necessary - saving your money 8 Mansour Mahran St, in front of Giza court, Giza gq I- A519 Sjall Sou plal- gba syns GLA Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com e@ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING 2) Soil resistivity surveys A comprehensive soil re: ivity survey is the key to creating an effective earthing system, as inadequate or erroneous soil resistivity readings are likely to result in a flawed design. EERECO site surveys take multiple accurate soil resistivity readings at various depths across the site. As these results form the basis of the whole earthing design, the experience of our engineers is critical in ensuring correct implementation of the test data. 3) Analysis & earthing design Using the latest computer aided design & modeling software we can produce detailed or budgetary earth electrode and lightning protection system designs, in compliance with recognized standards and whatever the complexity of system required, 4) Earth resistance measurement Earth resistance measurement is essential to accurately determine that the installed earthing system meets the anticipated criteria laid out in the initial design. Our technicians ensure all measurements are correctly taken ani interpreted, so that the true resistance of the earthing system can be accurately determined and verified. Compliance... EERECO designs comply with all recognized standards - national and international such as: — 8S 7430:2011 Code of practice for protective earthing of electrical installations — BS EN/IEC 62305 Protection against lightning — BS EN 50522:2010 - Earthing of power installations exceeding 1.k Vac — IEEE Std 80:2000 IEEE Guide for safety in AC substation grounding — NFPA 780 Standard for the installation of lightning protection systems 8 Mansour Mahran St, in front of Giza court, Giza BjyqI- 451591 Spall Uaioe plal- gla sgeata GLA Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com Typical customers & previous works @ EERECO EGYPTIAN FOR ELECTRICAL EARTHING Abu Simbel Airport - Satellite Station Luxor International Airport - Satellite Station Marsa Matruh International Airport - Satellite Station Cairo International Airport - Satellite Station Ramses Railway Station Data centers ‘National Bank of Egypt , Cairo Plaza Tower 1SCORE, Smart Village Alexandria Bank , Smart Village Etisalat misr , Ramses Post Building Etisalat misr, El Omraniya ‘Mobinil - El Hosary , 6th of October Pharaonic Petroleum Company Chevrolet Egypt Telecom Egypt, Sidi Gaber, Alexandria Government & public sector ‘Coinage Authority, El Darassa Abou Talat Telecom Central, Alexandria Administrative buildings ‘Raya Holding , 6th of October City Ministry of Local Development , Dokki PGESCO,, NEW CAIRO Coca Cola Atlantic Industries , Nasr City Free Zone Ragab Sons, Mostafa Einahhas branch Crédit Agricole Bank, Maadi Branch Crédit Agricole Bank, mansoura branch Egyptian Gulf Bank EGB, Port said Egypt Post, Smart Village Helwan Post Office, Helwan Medical sector & hospitals ‘Abu EI Reesh Hospital El-Hayat Scan, Downtown Police Hospital, Dokki 8 Mansour Mahran St, in front of Giza court, Giza Sj - ASL Syl LiSoee plal- olga spre ELSA Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING Hi Food (Ulker Egypt) Farm Frites Egypt Chloride Egypt Bridgestone Egypt White Point Elabd Universal Egypt Gulsan Egypt Media sector MBC Maser, Egyptian Media Production City Maspero television building, downtown Katameya Sporting (Petrosport) Club , New Cairo Olympia Sports Club, Dew Damietta ‘Tourism sector ‘Amwaj Oyoun Hotel & Resort, Sharm El Sheikh Le Meridien Dahab Resort , Dahab Porto Sharm Resort, Sharm El Sheikh Porto Matrouh Resort , Marsa Matruh 8 Mansour Mahran St, in front of Giza court, Giza ql ~ USL Spall Some plal- Gye spate Elo A Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com e@ EERECO EGYPTIAN FOR ELECTRICAL EARTHING. “Earthing" Is connecting the power system or electrical devices or building facilities to the earth. Earthing and bonding are an integral part of any modern electrical protection system design. An effective, low-impedance Earthing system is a key element of this system. It is crucial to help provide personnel safety, as well as reliable protection for vital equipments and to minimize interruptions of service and costly downtime. Itis a fundamental fact that electricity always flows to the point of lowest potential. The task is to help ensure that electricity, including faults, lightning and electronic noise flows to this point with maximum safety to people, while maintaining the reliability of equipment. Therefore we must help ensure the safe, controlled flow of electricity with minimum voltage drop to earth in all cases. 8 Mansour Mabran St, in front of Giza court, Giza aul = Sla9) Bia AaSKona pled colyge yqraie ELA Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO EGYPTIAN FOR ELECTRICAL EARTHING. The importance of reliable earthing Reliable protection of personnel and structures demands a systematic and comprehensive approach to minimizing threats caused by transients and other system disturbances. For instance, no air terminal can safely capture and arrest the lightning energy without a dependable route to earth, Equally, even the most expensive surge protection device (SPD) will not provide optimum protection if a low-impedance electrical connection to the earth is not present. There are important reasons why Earthing system should be installed. 1. The most important reason is to help protect people. 2. To help provide protection of structures and equipment from unintentional contact with live conductors, 3. To help support maximum safety from electrical system faults and lightning, A. Protect personal safety B. Ensure the electrical system working properly C. Prevent the hazards of lightening and over voltage 8 Mansour Mahran St, in front of Giza court, Giza Bygqll- LL pal LKowe plal- bee spania El A Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING Earthing system classification + Shock Protection Earthing & Lightning Protection Earthing Protective Earthing & Anti-Static Earthing Protective Earthing Functional Earthing Equipment Earthing > Neutral Earthing > Signal Earthing The possible hazards of unqualified earthing system Personal injuries Buildings or devices destroyed by the direct lightning ‘The devices destroyed caused by the earthing potential difference Data disorder of DCS system Stopped working of the equipments Static electricity protection became invalid The inflammable goods may be burned or exploded NOVAwWNE 8 Mansour Mahran St,, in front of Giza court, Giza Beal AB Bjgell AeSKone plal- Ghee sgpaia ELSA Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING. Characteristics of a Good Earthing System * Good electrical conductivity © Conductors capable of withstanding available electrical fault currents © Long life - at least 25 years ‘© Low earth resistance and impedance ‘The basic philosophy of any Earthing installation should be an attempt to maximize the surface area of electrodes or conductors with the surrounding soil. Not only does this help to lower the earth resistance of earthing system, but it also greatly improves the impedance of earthing system under lightning surge conditions. The key factors that impact earthing system 1. Conductivi When current flows from earth electrode into the surrounding soil, it is often described as flowing through a series of concentric shells of increasing diameter. Each successive shell has a greater area for current flow and consequently, lower resistance. At some point distant from the earth conductor the current dissipation becomes so large and current density so small, that the resistance is negligible There are tow factors: first, the conductivity of the earthing materials should be as high as possible, to facilitate the high current going through; second, the soil around earth electrodes should have good conductivity. The soil conductivity is the important factor that affects the earthing system ‘ance. It varies markedly for different soil types, moisture content and temperatures and gives rise to variations in earthing impedances. re 2. Electrical connection: The reliability of the electrical connection between earthing system and the devices or between earthing system components determines whether earthing system effective and safe or not. The connection breakoff of the key parts will cause failure to the entire earthing system. The voltage generated by a lightning discharge depends primarily on the rise-time of the current and the impedance (primarily inductance) of the path to earth. Exothermic welding connections provide excellent low impedance, long life electrical connections with excellent corrosion resistance. 3. Life span of the earthing materials As earthing electrode is buried in the soil, in the most cases it is often inconvenient to inspect and do maintenance. In this case, the earth electrode system should be corrosion resistant, and compatible with other conductors that are buried and bonded to the earthing system. Copper is by far the most common material used for earthing conductors. In general, some form of maintenance or inspection procedure should be adopted to ensure the long-term effectiveness of earthing system. 8 Mansour Mahran St, in front of Giza court, Giza jaqdI~ 4511 Syall Soe pal Glee spate Esl A Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com e@ EERECO EGYPTIAN FOR ELECTRICAL EARTHING 4, Thermo-stability: When the maximum short circuit current is getting through the conductor, the mechanical strength of the conductor should not lower down or blow out. 5. Earthing system structure Earthing system structure is designed based on the fully investigated of the actual application environment, soil resistivity and requirement analysis, and then under the premise of scientific analysis and calculations, with the least amount of work to achieve the best results. Reasonable design will be effectively earthing, while saving money; conversely, unreasonable design is not only a waste of money, but also results in unqualified earthing system which cannot remedy or amend. The efficiency of earthing system is dependent on a number of factors, including the geometry of the earthing electrode system, the shape of the conductors and the Equipotential bonding. bonding helps ensure that hazardous potential differences do not occur between different incoming conductors such as metallic water services, power systems, telecommunication systems and the local earth, and also minimizes step and touch potentials. Lightening protection system The transient nature of lightning with its associated fast rise times and large magnitude currents mean that special consideration needs to be given to Earthing, for lightning protection to be effective. Many factors such as soil resistivity variations, installation accessibility, layout and existing physical features are all sites specific and tend to affect decisions on earthing methods employed. The primary aim of a direct strike earthing system is to: ‘* Efficiently dissipate lightning energy into the earth ‘© Help protect equipment and personnel Low impedance is the key to lightning protection. All Earthing connections should be as short and direct as possible to minimize inductance and reduce peak voltages induced in the connections. Earthing electrode system must efficiently couple lightning surges into the earth by maximizing capacitive coupling to the soil. The resistance of the earth itself to lightning currents must also be minimized. Only when all these factors are taken into account will maximum lightning protection be achieved Major concepts of an integrated lightning protection strategy 1. Capture the lightning strike Convey this energy to the earth Dissipate energy into the Earthing system Bond all earthing points together Protect incoming AC power feeders Protect low voltage data/telecommunications circuits oy eeny 8 Mansour Mabran St, in front of Giza court, Giza Bead BILL Spall AySons pal clyge spate gL A Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING. Exothermic welding Exothermic welding is a simple, economical of making permanent, very high quality electrical connections. The process uses high temperature reaction of copper oxide and aluminum, within a semi- permanent graphite mould, to form electrical connections mainly between copper to copper or copper to steel. Now, exothermic welding has replaced the traditional method of physical connection between the metal. Exothermic welding is recommended to use in earthing system by many international standards. Locate the conductors (A) to be joined in the weld cavity (B) and close the mould (C) 2D Locate the stool retaining die in the base of the crucible (D). Pour in the weld powder ) followed by the starting powder (F). Ignite sarting powder with a spark gun, 3 The resting exothermic The molten copper alloy cook to leave 2 fision reaction reduces the weld ‘weld of great mechanical and electrical integrity. powder to molten copper alloy which mels the retaining disc and flows into the weld cavity where it partially mele the conductors (G) Reaction principle: 3Cu0 + 2Al + 3Cu + Al,0; + Heat(2537°C) 8 Mansour Mahran St,, in front of Giza court, Giza Bad USI Spel AySione plal~ ghee yguate giLA Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com Earthing System Component: @ exreco EGYPTIAN FOR ELECTRICAL EARTHING eerthrods Copperbond rod Threaded copperbond earth rods Tl ih Te Sk Weight Part no. Deving sts ianieter diameter ‘BY ianneter‘A’ excl 12> 200mm 9/16" 127mm L8kg BIOS. 12 150omm ote 17am 1.55kg | RBLO 12" Woden 127mm 17g RBS 127 240mm 97/16" (27am 236kg RBIS. 5/1200 5/8" 2mm 1.53kg RBDOS-FU 5/8 15000 42am akg BRIO 5/8 1800 MM2mm 20% RBIS, ss 200mm 20m 25tkg RBROFU 5/8" 2400 MW2mm 3.00 B25 Leases 5° 300mm 142mm 37g RBIS, couping 31200 2mm 219g RBS, 31500 172mm 273g RBSO 34" 80mm Mam 327g RBM. 3 240mm 72mm 4.35kg RSIS 34" 3000mm 172mm S44kg —_—RIBDIS, Fittings ype weigh Peo 12° Coupling omg G17 5/8 Coupling Dntke — €G270 3A Coupling Di3kg 370 1/2" Driving sud sk STI00 5A” Driving sd Dokks — ST200 344° Driving sud D.idkg _ST300 BS 7430, BS 6651, UL467 Rea Rod to cable clamp (type GUV) ‘Nominal rod Conductor Weight Part no. Gamer range net SAP 6m 16950? 930g ER TOO 3/8" 20mm 1670? 039g CRTOO* SAP eum 78S? 930g CRIS 3/8" 20mm 70150 039g CRS 5/8” i6um 150-300? kg CRTBO 43/4" 2mm 150-800mine 0g CRTBO 8 Mansour Mahran St. in front of Giza court, Giza Telefax : (202) 35729285 Seoul USL) Sead AgSious plal- Lee sguaie gil A Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com e@ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING ‘Nominal rod Max. ‘Weight Par no, Giameter Conductor each V2" 127mm 26x nm sk CRIS Sia” Yeo 25x 12mm 35h CRIS SM nm 25x Km D1Skg RIDE 5/5" loom Me 2mm ekg CRIB 3/4" Doom Sx 2am 16k CRB 5/7 tom 0x 2mm 024k CRO 5/87 téom St 4mm OR CRIS 3° 2m SLX 2mm Uh CRIS V2 127mm 2x2 2g CRIBO * Suitable foe we with Simm © solid cincule copper conductor Nominal rod Holo Tape Weight Part no. diameter centres width cach sa Sam = 2th GRBs as Sam = hg CRO r ‘Simm = tks RBIS sa Stam 25mm Hk CR320¢ 1a Som = 037g CRB2S 2 fmm dik CRI “UB threaded MID, GRID includes addtional plate to allow ape wo be lnnped without dling. Rod to cable lug clamp (type B) Rod to tape clamp (type A) SIR Nom 25x Rom 025k CRABO SI" mown 26x am 02Kg REID 17 Bom 24x 0mm 023g RI Rod to cable clamp (type G) ‘Nominal rod Gonductor Weight Part no. iameter "range each SIR” 95mm G35um? OTe RENS 12" 125mm 16m! sk CRSIOSFU® SI8" enm 16-700! OMe RSIS 3° 2mm 38-950! — OGY ERS 1° 2m e120? hg __ ERAS bolt rod clamp (type E) & Ere ‘Nominal rod Rod type ‘Bolt Weight Part no, ameter see ee 3S" 95mm Copperbond — MSs ORO 5/8" dom Copperboed — M10 3Pkg ORDA. 5/8" Som Solid copper MO 30g CRD VA" oe Copperbaed 8103s RDA, 34° aoe Sli copper 800 3okg CRO 8 Mansour Mahran St, in front of Giza court, Giza Telefax : (202) 35729285 Bgl BLN Spal LS plal- oles ope gl A Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com Lightweight inspection pit erpdon Wighe Pare nee CONTIN \iseee toy eras mnt” | een Ligwegrinpecion pt 18g) PTSON-FL Sneha orn tal Aconsorios “The lightweight impcion pit weigh oly od Decision eight ar no. ited #0 3:000ky Ihara tckable id and improed working ts sompund tothe conse mepesson ple eared ee um tin oy AKOOS Am nega cart bars ava w an option extra Mansfcaed Go high-pfemance ply the Highewght pie UV sable and chemaly rene Concrete inspection pit a ‘eeriion ‘weigh Pare ee aa a4 Concrete inspection pit he Pros: Accessories eons wie ee Shel cari ke P06 “elect ose Prve7 ‘The concrete inspection pits load rated co 4,500 and suitable for most eyps of earthing and lighening protection iselaions Ie snot table for use inane where high lod somal wheel vehicles teased The Lighrwcighe inpection pie (PT203) recommended for this ype of application 8 Mansour Mahran St, in front of Giza court, Giza Telefax : (202) 35729285 Syall- ALM Spall Lous plal- hae yyeaie gl A Mob : +2 ( 01064920513 - 01127278331) E-mail ; egy.earthing@gmail.com @ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING. Earth bars and disconnecting links ‘Wideh Height Weight Part no. en ee ES my ao ee = Gs aoe w eo 4 cm lat amen ot oes =e oe ee 4 = = © Be eens Scns eS Earth bars with single disconnecting lnk Description Width Hele Welt Pare 6 wy Som Youn Bg Sy Stn M6 2g LK say Simm Moon 3g 12a Stam Youn SKS 2 4 Sam M61 Yeway 105mm immo ive 25am Aamo LS 20ay 275mm Him Snes Skg KZA 23yay 375mm Him Sm .hg RAB 247 175mm Samm, ge L243 24 2évey —1575mm Wim Senmsg—L243- 26 2s vay 795mm Hmm Sinm—g LRA S0vsy 15mm Hams Tg L243. 30 Lnaor-s - Earth bars with twin disconnecting links a f Description Length Wilh ‘Height Weight —‘Part mo. ux 6 cach S * sim Xin ng LOT - mm — Mm orm tg OTR Lx286.6 20s five vom Sg EA Sinn mom Wit Sam 96mm Woden Siem So, {200mm Him 96mm 135m Sam 96m a a re {sm nm 6mm 165mm sam 96m 7.2 Recommended fixing = rundhesd woodserew 1 1/27 x 9016 o Widen Hem Mea sod wall pg All the above prodct conse of 50x 6mm ee ee ae ‘copper bi 8 Mansour Mahran St., in front of Giza court, Giza N= Aha dja ApSone plal- Ges syiaie gL A Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail: egy.earthing@gmail.com @ EERECO [EGYPTIAN FOR ELECTRICAL EARTHING Flexible copper braid bond ° ‘Ovenil bail Hole Ho Weight Part Ainiesions see’ centcer ach 25 3.5mm mm 2mm —0Ykg—-BNSOS 25% 50m How lam 05k BNSIO e Fesible copper bad for bonding gates, doors, ences ste, Equivalene eros scetinal area 38mm, Other ‘material, engd and sections avaiable a special tens, ‘Square tape Conductor Conductor ‘Weight Part no toe materi cach 253mm Copper o2tg CTH5-FU_ 25.x6nm Copper oatkg — CriW0 31x Copper 035g CTL SiN 6mm Copper 97k CTS Foe forming seaght through, cos oF te joints in pe an ba. Re-bar clamp Conductor Pipe Conductor Weight Part no, ameter diameter muterial— each J Copper 032g BNISO fw ____18-380m) Copper 075g BNISS For boning to reinforcing bars, steam pipes, handnik ee ‘Tower earth clamps ‘Conductor Chanwel Bolt Conductor Weight Part no. range thickness size material” each 1o-7omm! daar MIU Copper 3h BNIB ‘ot2imm? Mmm MIZ2_ Copper 023kg-—RNIBO 25:50mm mm MIO.—Copper 08g BNOOFU® i 25.S0mmn® nm «MI Akin 0.5K NOS {ap.tssmm! lames M12 Copper 050K N20 5-240? Hin MI2__ Copper hg BNR For bonding copper cable or wire ca see sruccures, > Suitable for we with Sn © solid circular condactor 8 Mansour Mahran St, in front of Giza court, Giza N= ASIA aja daSne plal- cle ygeaia BLA Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO EGYPTIAN FOR ELECTRICAL EARTHING Test and junction clamps ‘Square clamp ‘Conductor Conductor Weight Part no. ameter material each nm Copper 7k C8605 nm Aluminio —DO7Ke C8610 For forming cro or te joins Tee clamp Contain | Goiager wai Po oe diameter material each & fn Copper OdTag = 88S fem Amini 007 C5610 For fring jos ‘Square conductor clamp ‘Conductor Conductor Weight Past no, eT Stim? Copper 03g CRO 10 Copper 02g CRIS 95mm Copper 025g CREO Recommended Fixing - countersunk woodsrew 1 1/2" x n0.10 and wal plug For forming ssighedhrough cross a tee joins in cable Jointing clamp Conductor Conductor Weight Part no. lamer imaterial each fem Copper O7kg C8405 Sim Ahnu ODNy C8410 For forming stright ehrough join, 8 Mansour Mahran St, in front of Giza court, Giza jgall- Ab1a/Y1 Spall AaSome plal- gaa spate ELBA Telefax : (202) 35729285 Mob : +2 ( 01064920513 - 01127278331) E-mail : egy.earthing@gmail.com Conductor see OY) 125 x15um 1253 20 x Sum 20 x3 25 15inm Siu 2 Sau 315 Amen ‘Weight per meee 17g 033k, 027g 053g, 033k, 067k 089, 13h, 053k, ost, oT, 133k sak, 13 100m 4000 san 001 Teo roos ‘roo Tons Too. ‘roo reow rou ‘reo Tens ‘reots ‘Condacior size OGY) 31x Gn 38.30 30S, xen, 40.30 405m 40 640m 40 63mm 50x 40m 50x 63m 165k 1 Ike 16 143 1 203k 17 21k 224g. 13g 17k 220K 2g, 2k rom @ EERECO EGYPTIAN FOR ELECTRICAL EARTHING. Bare copper tape High conductivity copper tape to BS EN 13601 (formerly BS 1432), 25 x Sma also valle in Sima coil ize (TCOSI/50) Green & yellow PVC insulated copper tape PVC covered aluminium tape Conductor Weight Standard Past no. Sze OGY) permetre coll size 25% 3mm 079g hu" TCHLA-FU High conductivity copper pe to BS EN 1360 (oemerly BS 1492). PVC colours to BS 6746C. "Alo avaiable in 50m coil size (TC1L1/30), 20x3mn 125% 15mm 009g 2th 30h ‘TALOS Colour range Green Grey Stone White Brown "aay Ue IOBISO6c39 TANo TAS TAI TABS TAO Aluminiuat tape ro BS 2898-1350. PVC colours to Bs 2, * Green to BS 6746C. Other caloun are availible to onder: Contact Furs for details. Furse takes every precaution to ensure the UV stability of ts PV. coverings, but «with all plastic, colour variation wall occur over te 8 Mansour Mahran St, in front of Giza court, Giza Telefa: (202) 35729285 dS plal- glee spate gL A 2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO [EOYPTIAN FOR ELECTRICAL EARTHING Bare stranded copper cable Conductors Soft drawn stranded copper cable to BS 6360 CCeowsectional Stranding Weight Part no. Cromaectional Strning Weight Part no aca snos/men Oper mere area sno/men'O per mete fount TAD) 05k = CRM Tm? 37203 Ae TAT 18k CBOE Stu’ 7/205. EBISU nn! 7214 023k CBS INS LoThg CIES Sm 7232 32k CNIS 2A 220k; eae San! 19/178 ASR CBOSI-FU 00m? 276g CRBOO-FU rom 19721) 06g CBO? 6285. MOE em WAR Ose CRON Green and yellow PVC insulated stranded copper cable ‘Cross-sectional Stranding Weight Part no. Crostsectional Stranding Weight Part no see rnos/mm Oper metre area n/m © per metre ‘im TAT) O.19ke CONG mes? 372M. CCIE 2m 72102 CoS Stes 87H 1sihy €ciso.rU San? 7/252 oathg COB 8S" 3 20lkg oc som? W/A7R 05g COED 2m? == 64225 Oo? 1AM 073g CCUM Simms? 6282 Se CCAD sium! 17252 100g CCS Hen” 6/25. CCHOOLE PVC coveted oft drawn stranded copper cible to BS 600M, PVC colours to BS 6746C. Type H - High strength splitbolt connector Conductor range Male Tap Dimension Weight Part no, Min Max Min xB na ‘Sov? —Mdown! 2508 fon? — 4.) ke L Tein? Gens? 25cm! Loman 55mm Og «AH Gow? 25001? oun? 25mm" Ong Zone? Se? dont 3mm? Aun ODKkg IHL ‘50mm? Stow! dn? Sum? — 97am) ROE ‘Suna? Mean? dean? Wan? 12mm Og 2 Strnn? 9Sman? dn SS? 3.6mm TR SOR Stun? Ona? Ge? tkua? 147m Opa Sunn? 185i" Go? IAS? 182mm OBR 30M For capper to copper connections No speci tool requived. 8 Mansour Mahran St,, in front of Giza court, Giza Sool = LSI Bjgal UaSione plal- lye spuaie ELA Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail : egy.earthing@gmail.com @ EERECO EGYPTIAN FOR ELECTRICAL EARTHING Exothermic welding 8 Mansour Mabran St. in front of Giza court, Giza UaSone plal Glee spate gb A Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) EERECO EGYPTIAN FOR ELECTRICAL EARTHING EERECO EGYPTIAN FOR ELECTRICAL EARTHING & LIGHTNING PROTECTION fuse@ ERICO ONG 8 Mansour Mabran St, in front of Giza court, Giza Beall - USAW Spal Laos pled - cae specie ELA Telefax : (202) 35729285 Mob : +2 (01064920513 - 01127278331) E-mail: egy.earthing@gmail.com

You might also like