You are on page 1of 7

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53

APPLICABLE TO: PROPOSAL PURCHASE AS BUILT DATE SITE MANUFACTURER MODEL NOTE: INDICATES INFORMATION TO BE COMPLETED BY PURCHASER

REVISION FOR SERIAL NO. SERVICE DRIVER (6.1) BY MANUFACTURER

UNIT NO. REQUIRED

OPERATING CONDITIONS NORMAL


(3.33) (5.1.3)

MAXIMUM

OTHER CONDITIONS (5.1.4) A B C D

ALL DATA ON PER UNIT BASIS CERTIFIED POINT ( ) (5.1.4) GAS HANDLED (ALSO SEE PAGE 2) Required Capacity Nm3/h (1.013 bar & 0 C) (DRY ) (3.46 & 3.60) WEIGHT FLOW, kg/hr- (WET)(DRY) INLET CONDITIONS: COMPRESSOR INLET FLANGE CUSTOMER CONNECTION

PRESSURE - absolute (bar) TEMPERATURE (C) RELATIVE HUMIDITY (%) MOLECULAR WEIGHT (M) Cp/Cv (K1) OR (KAVG) (5.1.15.4) COMPRESSIBILITY (Z1) OR (ZAVG) (5.1.15.5) INLET VOLUME FLOW (m3/h) (3.19)

DISCHARGE CONDITIONS:

COMPRESSOR DISCHARGE FLANGE

CUSTOMER CONNECTION

PRESSURE - absolute (bar) TEMPERATURE (C) Cp/Cv (K2) OR (KAVG) COMPRESSIBILITY (Z2) OR (ZAVG) DEW POINT (C) OIL CARRYOVER (PPM-BY WT.) kW REQUIRED (ALL LOSSES INCL) SPEED (RPM) PRESSURE RATIO (R) VOLUMETRIC EFFICIENCY (%) SILENCER P (bar) (6.9.3) SETTLE OUT PRESSURE - absolute (bar) (5.1.5) PERFORMANCE CURVE NO.

PROCESS CONTROL: (6.4.2.1) METHOD: SLIDE VALVE BYPASS FROM TO BYPASS: MANUAL AUTO SPEED VARIATION FROM TO OTHER SIGNAL: SOURCE TYPE RANGE: FOR PNEUMATIC CONTROL RPM @ (bar) & OTHER SERVICE: SPECIAL PURPOSE (3.58) GENERAL PURPOSE (3.15) CONTINUOUS INTERMITTENT STANDBY (3.62) DRY SCREW (3.9)

REMARKS:

Unless otherwise noted, all pressures are GAGE pressures. (Example: bar refers to gage pressure; bar ab

RPM @ (bar) FLOODED SCREW (3.12) s. refe s to absolute pressure) r

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53

GAS ANALYSIS (5.1.15.4) MOL % M.W. AIR 28.966 OXYGEN NITROGEN WATER VAPOR CARBON MONOXIDE CARBON DIOXIDE HYDROGEN SULFIDE HYDROGEN METHANE ETHYLENE ETHANE PROPYLENE PROPANE l-BUTANE n-BUTANE l-PENTANE n-PENTANE HEXANE PLUS 32.000 28.016 18.016 28.010 44.010 34.076 2.016 16.042 28.052 30.068 42.078 44.094 58.120 58.120 72.146 72.146

NORMAL

MAXIMUM

OTHER CONDITIONS A B C D

REMARKS

(5.11.1.10)

CORROSIVE SOLID PARTICLE LIQUID PARTICLE NACE MATERIALS TOTAL AVG. MOL. WT. SITE DATA: LOCATION: INDOOR HEATED UNDER ROOF OUTDOOR UNHEATED PARTIAL SIDES GRADE MEZZANINE WINTERIZATION REQ'D. TROPICALIZATION REQ'D. ELEVATION m BAROMETER (bar a RANGE OF AMBIENT TEMPS.: BULB WET BUL SITE RATED C NORMAL C MAXIMUM C MINIMUM C ELECTRICAL AREA CLASSIFICATION:(5.1.18) ZONE GROUP CLASS AREA: CL. DIV. UNUSUAL CONDITIONS: DUST FUMES OTHER

(5.11.1.7) (5.1.25) (5.1.25) (5.11.1.10)

DRY

NOISE SPECIFICATIONS: (5.1.19) APPLICABLE TO MACHINE SEE SPECIFICATION APPLICABLE TO NEIGHBORHOOD SEE SPECIFICATION YES NO SOUND LEVEL dB @ m dB RE: 20 MICRO PASCAL APPLICABLE SPECIFICATIONS: API 619 POSITIVE DISPLACEMENT ROTARY COMPRESSORS ACOUSTIC MOTOR bs.) B

GR.

PAINTING: MANUFACTURER'S STD. OTHER

VENDOR HAVING UNIT RESPONSIBILITY: (3.65)

SHIPMENT: (7.4.1) DOMESTIC MONTHS

EXPORT

EXPORT BOXING REQ'D LONG TERM STORAGE FOR

REMARKS:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53

SPEEDS: MAX. CONT. (3 26) RPM TRIP (3.64) RPM MAX. TIP SPEEDS: m/s @ MAX. OPER. SPEED MIN. ALLOW (3.30) RPM LATERAL CRITICAL SPEEDS: (5.7.1.4) FIRST CRITICAL RPM DAMPED UNDAMPED MODE SHAPE LATERAL CRITICAL SPEED - BASIS: DAMPED UNBALANCE RESPONSE ANALYSIS OTHER TYPE ANALYSIS: (SPECIFY) POCKET PASSING FREQUENCY: Hz TORSIONAL CRITICAL SPEEDS: (5.7.2) FIRST CRITICAL RPM SECOND CRITICAL RPM VIBRATION: (5.7.3.6) HOUSING mm/s RMS SHAFT ROTATION, LOOK AT COMPRESSOR DRIVEN END: CW CCW CASING: MODEL CASING SPLIT MATERIAL CLADDING (5.2.10) OPERATION: DRY FLOODED, w/ LIQUID THICKNESS (mm.) CORR. ALLOW (mm.) MAX. ALLOWABLE WORK PRESS. (3.25) (bar) RELIEF VALVE SETTING (bar) MARGIN FOR ACCUMULATION (bar) LEAK TEST GAS: PRESS (bar)(kPa): (7.3.3.4.3.1) TEST PRESS. (bar) (7.3.4.6) HYDRO (7.3.2) MAX. ALLOW. TEMP. C MIN. OPER. TEMP. C COOLING JACKET YES NO ROTORS: (5.5.1) DIAMETER (mm.): MALE: FEMALE: NO. LOBES: MALE FEMALE TYPE: TYPE FABRICATION MATERIAL MAX. YIELD STRENGTH (N/mm2) BRINELL HARDNESS. MAX. MIN. ROTOR LENGTH TO DIAMETER RATIO (L/D) M: ROTOR CLEARANCE (mm) INTERNALLY COOLED YES NO

SHAFT: (5.5.1.2) MATERIAL DIA @ ROTORS (mm) DIA @ COUPLING (mm) SHAFT END. TAPERED CYLINDRICAL (5.5.1.5 & 5.5.1.6) SHAFT SLEEVES: AT SHAFT SEALS MATL. TIMING GEARS: (5.5.2) PITCH LINE DIAMETER (mm) MALE: FEMALE: MATERIAL TYPE SHAFT SEALS: (5.6) SEAL SYSTEM TYPE (5.6.1.7) OIL LEAKAGE (CC/MIN/SEAL) TYPE BUFFER GAS (5.6.2.2) BUFFER GAS FLOW (PER SEAL) NORMAL: kg/hr. @ (bar) MAX.: kg/hr. @ (bar) BEARING HOUSING: (5.9) TYPE (SEPARATE, INTEGRAL) SPLIT MATERIAL
HYDRODYNAMIC RADIAL BEARINGS: (IDENTIFY HIGHEST LOADED BEARING) (5.8)

TYPE SPAN (mm) AREA (mm2) LOADING (N/mm2): ACT. NO. PADS ROTOR ON OR BETWEEN TYPE BABBITT THICKNESS TC RTD TYPE NO PER BRG ROLLING ELEMENT RADIAL BEARING (5.8.2) TYPE: ENERGY DENSITY (kW-RPM):

ALLOW. PADS PAD MATERIAL (mm) TEMP SENSORS (5.8.1.5)

Ndm:

HYDRODYNAMIC THRUST BEARING: (IDENTIFY HIGHEST LOADED BEARING)

"(5.8)
(mm2) LOADING (N/mm2): PAD MATERIAL TYPE BABBITT TC RTD TYPE NO PER BRG

TYPE MFR. ACT. THICKNESS ACTIVE INACTIVE

AREA ALLOW. NUMBER OF PADS (mm) TEMP SENSORS (5.8.1.5)

ROLLING ELEMENT THRUST BEARING (5.8.2) TYPE: ENERGY DENSITY (kW-RPM):

Ndm:

REMARKS:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53

UTILITY CONDITIONS: (ALL UNITS ARE GAUGE) STEAM DRIVERS HEATING INLET MIN. (bar) C (bar) C NORM (bar) C (bar) C MAX. (bar) C (bar) C EXHAUST MIN. (bar) C (bar) C NORM (bar) C (bar) C MAX. (bar) C (bar) C ELECTRICITY: SHUT- DRIVERS HEATING CONTROL DOWN VOLTAGE HERTZ PHASE COOLING WATER TEMP. INLET C MAX. RETURN C PRESS. NORM (bar) DESIGN (bar) MIN. RETURN (bar) MAX. ALLOW P (bar) WATER SOURCE INSTRUMENT AIR: MAX PRESS (bar) MIN. (bar) TOTAL UTILITY CONSUMPTION: COOLING WATER m 3/h STEAM, NORMAL kg/h STEAM, MAX kg/h INSTRUMENT AIR Nm 3/h HP (DRIVER) kW

WEIGHTS (KG): COMPR. GEAR DRIVER BASE ROTORS: COMPR. DRIVER GEAR COMPR. UPPER CASE L.O. CONSOLE S.O. CONSOLE MAX. FOR MAINTENANCE (IDENTIFY) TOTAL SHIPPING WEIGHT

SPACE REQUIREMENTS (mm): COMPLETE UNIT W H S.O. CONSOLE:

W L

H L.O. CONSOLE W H

MISCELLANEOUS: RECOMMEND STRAIGHT RUN OF PIPE DIA. BEFORE SUCTION VENDOR'S REVIEW & COMMENTS ON PURCHASER'S PIPING & FOUNDATION (5.1.16) VENDOR REPRESENTATIVE OBSERVATION AT THE SITE (5.1.17) OPTICAL ALIGNMENT FLATS REQUIRED ON COMPRESSOR, GEAR & DRIVER LATERAL ANALYSIS & REPORT REQUIRED (5.7.1.4) TORSIONAL ANALYSIS REPORT REQUIRED (5.7.2.1) CASING MOUNTED TORSIONAL SHAFT VIBRATION PICKUP COORDINATION MEETING (8.1.3)

SHOP INSPECTION AND TESTS:(7.1) REQ'D WITNESS OBSERVE SHOP INSPECTION (7.1.5) HYDROSTATIC (7.3.2) HELIUM LEAK (7.3.4.6) MECHANICAL RUN (7.3.3) MECHANICAL RUN SPARE ROTORS(7.3.3.4.2) CASING LEAK TEST (7.3.3.4.3) PERFORMANCE TEST (GAS) (AIR) (7.3.4.1) COMPLETE UNIT TEST (7.3.4.2) USE SHOP LUBE & SEAL SYSTEM USE JOB LUBE & SEAL SYSTEM (7.3.4.8) USE SHOP VIBRATION PROBES, ETC. USE JOB VIB. & AXIAL DISP. PROBES USE JOB SEISMIC TRANSDUCERS USE JOB MONITORING EQUIPMENT PRESSURE COMP. TO FULL OPER. PRESSURE DISASSSEMBLEREASSEMBLE COMP. AFTER TEST(7.3.4.9) SOUND-LEVEL TEST (7.3.4.7) TANDEM (7.3.4.4) AUX. EQUIPMENT (7.3.4.8) FULL-LOAD TEST (7.3.4.10) RESIDUAL UNBALANCE CHECK(5.7.3.5)

INLET & DISCHARGE DEVICES: HIGH EFFICIENCY INLET SEPARATOR REQUIRED (6.8.2) INLET AIR FILTER DP INDICATION TYPE (6.7.3) PULSATION SUPPRESSORS FURNISHED BY SPARE PARTS TO BE SUPPLIED (8.2.3F) ROTOR ASSEMBLY SEALS GASKETS, O-RINGS START-UP/COMMISSIONING 2 YEARS SUPPLY OTHER: REMARKS:

VENDOR MUST FURNISH ALL PERTINENT DATA FOR THIS SPECIFICATION SHEET BEFORE RETURNING. ITEM NO. SERVICE

JOB NO. MANUFACTURER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49

REFERENCE SPECIFICATIONS: (6.4.1.2) API 614 YES NO

APPLICABLE SPECIFICATIONS: ZONE GROUP AREA: CL. GR. DIV. VOLTAGE: VOLTS PHASE ALARM & SHUTDOWN VOLTAGE: VOLTS PHASE

IEC

NEMA AREA CLASSIFICATION: CLASS NON-HAZARDOUS MOTOR CONTROL & INSTRUMENT CYCLES CYCLES OR DC

LOCAL CONTROL PANEL: (6.4.3) FURNISHED BY: VENDOR PURCHASER OTHERS FREE STANDING WEATHERPROOF TOTALLY ENCLOSED ANNUNCIATOR: FURNISHED BY: VENDOR PURCHASER CUSTOMER CONNECTIONS BROUGHT OUT TO TERMINAL BOXES BY VENDOR

EXTRA CUTOUTS VIBRATION ISOLATORS OTHERS ANNUNCIATOR LOCATED ON

STRIP HEATERS LOCAL PANEL

PURGE CONNECTIONS MAIN CONTROL BOARD

INSTRUMENT SUPPLIERS: PRESSURE GAUGES: MFR. SIZE & TYPE: LEVEL GAUGES: SIZE & TYPE: PRESSURE SWITCHES: SIZE & TYPE: TEMPERATURE SWITCHES: SIZE & TYPE: CONTROL VALVES: SIZE & TYPE: THERMAL RELIEF VALVES: (6.4.4.6.4) SIZE & TYPE: GAS FLOW INDICATOR: SIZE & TYPE: TACHOMETER: (6.4.4.2) SIZE & TYPE: ANNUNCIATOR: (6.4.5.9) MFR. SIZE & TYPE: MFR. SIZE & TYPE:

MFR. MFR. MFR. MFR. MFR. MFR. MFR.

SIZE & TYPE: TEMPERATURE GAUGES: SIZE & TYPE: DIFF. PRESSURE GAUGES: SIZE & TYPE: DIFF. PRESSURE SWITCHES: SIZE & TYPE: LEVEL SWITCHES: SIZE & TYPE: PRESSURE RELIEF VALVES: (6.4.4. 6) SIZE & TYPE: FLOW INDICATORS: (6.4.4. 9) SIZE & TYPE: VIBRATION EQUIPMENT: RANGE & TYPE: SOLENOID VALVES MODEL & NO. POINTS DEPRESSURIZATION VALVE (6.4.4. 7)

MFR. MFR. MFR. MFR. MFR. MFR. MFR. MFR. MFR.

NOTE:

SUPPLIED BY VENDOR

SUPPLIED BY PURCHASER LOCALLY LOCAL FUNCTION MOUNTED (3.21) PANEL (3.38) GOV. CONTROL OIL GOV. CONTROL OIL P MAIN STEAM IN 1ST STAGE STEAM STEAM CHEST EXHAUST STEAM EXTRACTION STEAM STEAM EJECTOR COMPRESSOR SUCTION COMPRESSOR DISCHARGE

PRESSURE GAUGE REQUIREMENTS LOCALLY LOCAL FUNCTION MOUNTED (3.21) PANEL (3.38) LUBE OIL PUMP DISCHARGE LUBE OIL FILTER P LUBE OIL SUPPLY SEAL OIL PUMP DISCHARGE SEAL OIL FILTER P SEAL OIL SUPPLY (EACH LEVEL) SEAL OIL DIFFERENTIAL REFERENCE GAS BALANCE LINE SEAL EDUCTOR BUFFER SEAL OIL/GAS COALESCING FILTER D P

VENDOR MUST FURNISH ALL PERTINENT DATA FOR THIS SPECIFICATION SHEET BEFORE RETURNING. ITEM NO. SERVICE

JOB NO. MANUFACTURER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 41 42 43 44 45 46 47 48 49 50

TEMPERATURE GAUGE REQUIREMENTS: LOCALLY LOCAL FUNCTION MOUNTED (3.21) PANEL (3.28) LUBE OIL DISCHARGE FROM EA. COMPR. JOURNAL BEARING DRIVER JOURNAL BEARING GEAR JOURNAL BEARING COMPRESSOR THRUST BEARING DRIVER THRUST BEARING GEAR THRUST BEARING

LOCALLY LOCAL FUNCTION MOUNTED (3.21) PANEL (3.28) COOLER OIL INLET & OUTLET SEAL OIL OUTLET COMPRESSOR SUCTION COMPRESSOR DISCHARGE LUBE OIL RESERVOIR LUBE OIL SUPPLY

MISCELLANEOUS INSTRUMENTATION: DRIVER START/STOP LOCAL PANEL SEPARATE PANEL MAIN BOARD SIGHT FLOW INDICATORS, EACH JOURNAL & THRUST BEARING & EACH COUPLING OIL RETURN LINE SIGHT FLOW INDICATORS, EACH SEAL OIL RETURN LINE LEVEL GAUGES, LUBE AND/OR SEAL OIL RESERVOIR, S.O. DRAIN TRAPS & S.O. OVERHEAD TANK VIBRATION AND SHAFT POSITION PROBES & PROXIMITORS VIBRATION AND SHAFT POSITION READOUT EQUIPMENT VIBRATION READOUT LOCATED ON: LOCAL PANEL SEPARATE PANEL MAIN BOARD TURBINE SPEED PICKUP DEVICES TURBINE SPEED INDICATORS TURBINE SPEED INDICATORS LOCATED ON: LOCAL PANEL MAIN BOARD REMOTE HAND SPEED CHANGER - MOUNTED ON LOCAL PANEL ALARM HORN & ACKNOWLEDGMENT SWITCH

ALARM & SHUTDOWN: (6.4.5.2) FUNCTION ALARM TRIP LOW LUBE OIL PRESSURE HI LUBE OIL FILTER P HI SEAL OIL FILTER P LOW LUBE OIL RESERVOIR LEV. LOW SEAL OIL RESERVOIR LEV. HI SEAL OIL LEVEL LOW SEAL OIL LEVEL HI SEAL OIL PRESSURE LOW SEAL OIL PRESSURE AUX. SEAL OIL PUMP START AUX. LUBE OIL PUMP START HI SEAL OIL OUTLET TEMP. (COOLER) HI LIQUID LEV. SUCT. SEPARATOR COMPRESSOR HI DISCH. TEMP. COMPRESSOR VIBRATION COMPRESSOR AXIAL POSITION HI LUBE OIL SUPPLY TEMPERATURE

PREFUNCTION ALARM TRIP TURBINE VIBRATION TURBINE AXIAL POSITION GEAR VIBRATION GEAR AXIAL POSITION COMPRESSOR MOTOR SHUTDOWN TRIP & THROTTLE VALVE SHUT HI TURB. STEAM SEAL LEAKAGE HI COMPR. THRUST BRG. TEMP. HI COMPR. JOURNAL BRG. TEMP. HI DRIVER THRUST BRG. TEMP. HI DRIVER JOURNAL BRG. TEMP. HI GEAR THRUST BRG. TEMP. HI GEAR JOURNAL BRG. TEMP. COMPRESSOR P LOW SEAL GAS PRESSURE HI COALESCING GAS/OIL FILTER D P

CONTACTS: ALARM CONTACTS SHALL: OPEN CLOSE TO SOUND ALARM AND BE NORMALLY OPEN CLOSE TO TRIP AND BE NORMALLY ENERGIZED DE-ENERGIZED NOTE: NORMAL CONDITION IS WHEN COMPRESSOR IS IN OPERATION.

ENERGIZED

DE-ENERGIZED SHUTDOWN CONTACTS SHALL:

MISCELLANEOUS: INSTRUMENT TAGGING REQUIRED. ALARM AND SHUTDOWN SWITCHES SHALL BE SEPARATE. PURCHASERS ELECTRICAL AND INSTRUMENT CONNECTIONS WITHIN THE CONFINES OF THE BASEPLATE AND CONSOLE SHALL BE: MADE DIRECTLY BY THE PURCHASER. COMMENTS REGARDING INSTRUMENTATION:

BROUGHT OUT TO TERMINAL BOXES.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52

APPLICABLE TO: PROPOSAL PURCHASE FOR SITE NO. REQURED MANUFACTURER MODEL NOTE: INDICATES INFORMATION TO BE COMPLETED BY PURCHASER

AS BUILT UNIT DRIVEN EQUIP. SERVICE SERIAL NO. BY MANUFACTURER

MOTOR DESIGN DATA APPLICABLE SPECIFICATIONS: IEC NEMA API 541 (6.1.2.2) SITE DATA: ZONE GROUP CLASS AREA: CL. GR. DIV. NON-HAZARDOUS ALT. m AMB. TEMPS: MAX. C, MIN C UNUSUAL CONDITIONS: DUST FUMES OTHER DRIVE SYSTEM: DIRECT CONNECTED GEAR OTHER TYPE MOTOR: (6.1.2.1) SQUIRREL CAGE INDUCTION NEMA DESIGN SYNCHRONOUS POWER FACTOR REQD. EXCITATION: BRUSHLESS SLIP RING FIELD DISCHARGE RESISTOR BY MOTOR MFR. WOUND ROTOR INDUCTION ENCLOSURE: (6.1.2.1.c) TEFC

MOTOR DESIGN DATA (CONT'D) STARTING: (6.2.1.1 b) FULL VOLTAGE UNLOADED VOLTAGE DIP VIBRATION: IEC STANDARD NOISE: IEC STANDARD REDUCED VOLTAGE % NEMA STANDARD NEMA STANDARD % LOADED

ACCESSORY EQUIPMENT BASEPLATE SOLEPLATE STATOR SHIFT MFR. STD. FANS SPARKING FANS D.C. EXCITATION: KW REQD VOLTS BY: PURCHASER MANUFACTURER DESCRIPTION ENCLOSED COLLECTOR RINGS: PURGED: MEDIUM PRESS. (BARG) (KPa) EXPLOSION-RESISTANT NON-PURGED FORCED VENTILATION mh/h PRESS. DROP mm H 2O BEARING TEMP DEVICES: LOCATION NON-

TEWAC

TEIGF, USING

GAS P mm

DESCRIPTION SET @ C FOR ALARM C FOR SHUTDOWN SPACE HEATERS: KW VOLTS PHASE HERTZ MAX. SHEATH TEMP. C WINDING TEMPERATURE DETECTORS: THERMISTORS: NO./PHASE TYPE: POS. TEMP. COEFF. NEG. TEMP. COEFF. TEMPERATURE SWITCH: YES NO RESISTANCE TEMPERATURE DETECTORS: NO./PHASE RESISTANCE MATL. OHMS SELECTOR SWITCH & INDICATOR BY: PURCHR. MFR. MAX. STATOR WINDING TEMPS: C FOR ALARM C FOR SHUTDOWN WINDING TEMP. DETECTOR & SPACE HEATER LEADS: IN SAME CONDUIT BOX IN SEPARATE CONDUIT BOXES MOTOR ARRANGED FOR DIFFERENTIAL PROTECTION: SELF-BALANCE PRIMARY CURRENT METHOD C.T. DESCRIPTION EXTENDED LEADS LENGTH m SURGE CAPACITORS

DOUBLE WALL CARBON STEEL TUBES WATER SUPPLY: PRESS. (bar) (kPa) TEMP. C WATER ALLO (bar) (kPa) & TEMP. RISE C WATER SIDE MIN. CORR. ALLOW. AND FOUL FACTOR (AIR) (GAS) SUPPLY PRESS. (bar) (kPa) WEATHER PROTECTED, TYPE FORCED VENTILATED OPEN-DRIPPROOF OPEN EExe. EExpe EEexd(e) Exnxp / ExN BASIC DATA: VOLTS PHASE HERTZ NAMEPLATE kW SERVICE FACTOR (6.1.2.1.g) SYNCHRONOUS RPM INSULATION: CLASS TYPE TEMP. RISE: C ABOVE C BY