Transcoding and Rate Adaption Unit OML:TRAU
A30808-X3247-M440-1-7619

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

Copyright Siemens Mobile Communications S.p.A. 2005

Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

This document consists of a total of 176 pages. Insert the document in binder: OML:TRAU

Reason for Update


Chapter/Section 4.1.6 Reason for Update FEKAT DE2667

Issue History
Issue Number 4 Date of Issue 11/2005 Reason for Update New Edition for Release BR8.0

A30808-X3247-M440-1-7619

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

1 Contents
1 2 3 3.1 Contents ...................................................................................................................................................5 Introduction...............................................................................................................................................9 GSM Probable Causes...........................................................................................................................15 Equipment Failure ..........................................................................................................................15 3.1.1 1006 - PLL_FAILURE .............................................................................................................15 3.1.2 1007 - BSCI_HW_FAULT .......................................................................................................16 3.1.3 1009 - TRAC_TIMING_LOSS .................................................................................................20 3.1.4 1012 - PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT ...........................................21 3.1.5 1020 - PCMS_CIRCUIT_ALARM............................................................................................22 3.1.6 1021 - PCMA_CIRCUIT_ALARM............................................................................................24 3.1.7 1042 - BSMS_DIAGNOSTIC_FAILURE .................................................................................26 3.1.8 1045 - TRAC_DIAGNOSTIC_FAILURE .................................................................................27 3.1.9 1047 - TRAC_DIAGNOSTIC_ONLINE_FAILURE ..................................................................28 3.1.10 1052 - TPWR_DIAGNOSTIC_FAILURE.................................................................................30 3.1.11 1059 - MSCI_HW_FAULT.......................................................................................................31 3.1.12 1074 - TPWR_FAULT .............................................................................................................32 3.1.13 1077 - TRAC_HW_FAULT......................................................................................................33 3.1.14 1078 - MSCI_SYNC_8KHZ_FAILED ......................................................................................34 3.1.15 1079 - MSCI_DIGA_FAULTED...............................................................................................35 3.1.16 1081 - TRAC_FAIL_TO_LOAD...............................................................................................36 3.1.17 1082 - FLASH_EPROM_NOT_VALID ....................................................................................37 3.1.18 1086 - TRAC_LINK_FAILURE ................................................................................................39 3.1.19 1088 - TRAC_CARD_FAILURE..............................................................................................40 3.1.20 1089 - DSP_FAIL_TO_LOAD .................................................................................................41 3.1.21 1100 - BSCI_CARD_FAILURE ...............................................................................................42 3.1.22 1104 - BSCI_KEEP_ALIVE_ALARM ......................................................................................43 3.1.23 1105 - MSCI_KEEP_ALIVE_ALARM......................................................................................44 3.1.24 1106 - INCONSISTENT_STATUS ..........................................................................................45 3.2 Line Interface Failure......................................................................................................................46 3.2.1 11 - LOSS_OF_SIGNAL .........................................................................................................46 3.2.2 12 - AIS_ALARM .....................................................................................................................48 3.2.3 18 - LOSS_OF_SIGNAL_ON_LINK_A ...................................................................................50 3.2.4 19 - LOSS_OF_SIGNAL_ON_LINK_B ...................................................................................52 3.2.5 20 - AIS_ALARM_ON_LINK_A ...............................................................................................54 3.2.6 21 - AIS_ALARM_ON_LINK_B ...............................................................................................56 3.3 Loss of Synchronisation .................................................................................................................58 3.3.1 1097 - BAD_PLL_INPUT_SYNCHRONISATION ...................................................................58 3.4 Database Inconsistency .................................................................................................................59 3.4.1 1019 - INVALID_DATABASE_WARNING ..............................................................................59 3.4.2 1023 - TRAC_DBA_REFUSED...............................................................................................60 3.4.3 1091 - DATABASE_INCONSISTENCY_BRINGUP................................................................61 3.4.4 1102 - PROBABLE_DATABASE_INCONSISTENCY.............................................................62 3.5 Input Parameter out of Range ........................................................................................................63 3.5.1 1015 - INPUT_PARAMETER_OUT_OF_RANGE_WARNING...............................................63 3.6 Invalid Pointer .................................................................................................................................64 3.6.1 1114 - INVALID_POINTER_WARNING .................................................................................64 3.7 Message not Expected ...................................................................................................................65 3.7.1 1014 - UNEXPECTED_MESSAGE.........................................................................................65 3.7.2 1044 - INVALID_MESSAGE_DATA........................................................................................66 3.7.3 1048 - INVALID_RTE_HEADER_FIELD_VALUE...................................................................67 3.7.4 1060 - MSCI_SW_ERROR .....................................................................................................68 3.7.5 1080 - TRAC_UNEXPECTED_MESSAGE.............................................................................69 3.8 Message Out of Sequence.............................................................................................................70 5

A30808-X3247-M440-1-7619

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

3.8.1 1033 - MESSAGE_OUT_OF_SEQUENCE_WARNING.........................................................70 System Call Unsuccessful..............................................................................................................72 3.9.1 1024 - SYSTEM_CALL_UNSUCCESSFUL_WARNING ........................................................72 3.9.2 1028 - FUNCTION_CALL_UNSUCCESSFUL........................................................................74 3.9.3 1066 - MESSAGE_NOT_SENT ..............................................................................................77 3.9.4 1067 - INVALID_DB_CALL .....................................................................................................79 3.9.5 1096 - SYSTEM_CALL_UNSUCCESSFUL_MINOR .............................................................80 3.10 Timeout Expired .............................................................................................................................81 3.10.1 1037 - TIMEOUT_EXPIRED_WARNING ...............................................................................81 3.10.2 1075 - TRAC_KEEP_ALIVE_ALARM .....................................................................................85 3.10.3 1087 - DSP_TSYNC_EXPIRED..............................................................................................86 3.10.4 1090 - DSP_KEEP_ALIVE_ALARM .......................................................................................87 3.11 Variable Out of Range ....................................................................................................................91 3.11.1 1029 - VARIABLE_OUT_OF_RANGE....................................................................................91 3.12 Watch Dog Timer Expired ..............................................................................................................92 3.12.1 1003 - TRAC_WDT_TIMEOUT...............................................................................................92 3.12.2 1004 - BSCI_WDT_TIMEOUT ................................................................................................93 3.12.3 1005 - BSCI_WDT_WARNING ...............................................................................................94 3.13 FAN Failure ....................................................................................................................................95 3.13.1 5002 - FAN_ALARM................................................................................................................95 3.14 System Resources Overload..........................................................................................................96 3.14.1 1115 - UNABLE_TO_RUN_TEST...........................................................................................96 3.15 LAPD Link Protocol Failure ............................................................................................................97 3.15.1 2001 - ASUB_TRANSIENT_FAILURE ...................................................................................97 3.15.2 2003 - LPDL_LINK_DOWN.....................................................................................................98 3.16 Remote alarm indication.................................................................................................................99 3.16.1 15 - REMOTE_ALARM ...........................................................................................................99 3.16.2 26 - REMOTE_ALARM_ON_LINK_A ...................................................................................101 3.16.3 27 - REMOTE_ALARM_ON_LINK_B ...................................................................................103 3.17 Transmission Error .......................................................................................................................105 3.17.1 16 - HIGHER_BER_THRESHOLD_EXCEEDED .................................................................105 3.17.2 17 - LOWER_BER_THRESHOLD_EXCEEDED ..................................................................107 3.17.3 28 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A ...........................................109 3.17.4 29 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B ...........................................111 3.17.5 30 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A ............................................113 3.17.6 31 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B ............................................115 3.9 4 ITU Probable Causes ...........................................................................................................................117 Configuration Or Customization Error ..........................................................................................117 4.1.1 1010 - HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER ...........................................117 4.1.2 1032 - TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION ..................118 4.1.3 1036 - BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE ...........................................119 4.1.4 1038 - MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE ..........................................120 4.1.5 1103 - TPWR_OFFREQUEST_PENDING ...........................................................................121 4.1.6 1116 - TRAC_HW_NOT_COMPATIBLE_WITH_VQE .........................................................122 4.1.7 2002 - UNEXPECTED_TEI...................................................................................................123 4.2 Congestion ...................................................................................................................................124 4.2.1 1098 - T_INTERFACE_MESSAGE_LOST ...........................................................................124 4.3 Corrupt Data .................................................................................................................................125 4.3.1 1083 - FLASH_EPROM_MUST_BE_FORMATTED.............................................................125 4.3.2 1108 - FORMATTING_FLASH_EPROM ..............................................................................127 4.3.3 1109 - INVALID_FILE_FORMAT ..........................................................................................128 4.4 Enclosure Door Open ...................................................................................................................130 4.4.1 5001 - OPEN_DOOR_ALARM..............................................................................................130 4.5 Loss Of Frame..............................................................................................................................131 4.5.1 13 - LOSS_OF_FRAME_ALIGNMENT.................................................................................131 4.5.2 14 - LOSS_OF_CRC_ALIGNMENT .....................................................................................133 4.5.3 22 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A...........................................................135 4.1 A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

4.5.4 23 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B...........................................................136 4.5.5 24 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_A ...............................................................137 4.5.6 25 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_B ...............................................................138 4.6 Out Of Memory .............................................................................................................................139 4.6.1 1040 - MEMORY_NOT_AVAILABLE....................................................................................139 4.6.2 1041 - MAILBOX_CANNOT_BE_CREATED........................................................................140 4.6.3 1093 - EMPTY_RTE_POOL_RESTART ..............................................................................141 4.6.4 1094 - EMPTY_MESSAGE_POOL.......................................................................................142 4.6.5 1113 - MEMORY_OVERFLOW ............................................................................................143 4.7 Software Error ..............................................................................................................................144 4.7.1 1016 - AR_PROCEDURAL_ERROR....................................................................................144 4.7.2 1017 - RTE_INTERRUPT_LOOP .........................................................................................145 4.7.3 1018 - STANDBY_ALIGNMENT_FAILED ............................................................................146 4.7.4 1034 - SCHEDULER_BLOCKED..........................................................................................147 4.7.5 1035 - INITIALIZATION_UPDATED .....................................................................................148 4.7.6 1043 - INITIALIZATION_FAILURE .......................................................................................149 4.7.7 1046 - FILE_SYSTEM_ERROR............................................................................................151 4.7.8 1049 - INTERNAL_LINK_FAILURE ......................................................................................154 4.7.9 1053 - BSMS_PROCEDURAL_ERROR...............................................................................155 4.7.10 1068 - TIMER_CANNOT_BE_SET.......................................................................................156 4.7.11 1084 - STANDBY_NOT_ALIGNED.......................................................................................158 4.7.12 1099 - RTE_AUDIT_ERROR ................................................................................................159 4.7.13 1107 - BSCI_RESET_CAUSE ..............................................................................................160 4.7.14 1110 - PERIPHERAL_LOADING_ERROR...........................................................................162 4.8 Software Program Abnormally Terminated ..................................................................................163 4.8.1 1111 - DELETED_CURRENT_TASK ...................................................................................163 4.8.2 1112 - DELETED_CURRENT_INIT_FUNCTION .................................................................164 5 6 7 8 Index of Specific Problems...................................................................................................................165 ANNEX A..............................................................................................................................................169 ANNEX B..............................................................................................................................................173 ANNEX C..............................................................................................................................................175

A30808-X3247-M440-1-7619

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

2 Introduction
This manual contains the description of all errors that the SBS/TRAU system can generate. An example of one error printout from Local Terminal is shown in Figure 1. This output manual is just a listing of all possible system messages. Output manuals can not substitute or replace maintenance manuals and are only intended for the support of experienced personnel when performing specialized fault clearance tasks.
JOB: 11 PC Time&Date: 11:05:49 01/22/2001 NE Time&Date: 11:29:31 22/01/2001 USER: LMT User SW RELEASE: 02-06-01-01-03-00_01-01-19 COMMAND RESULT: Successful FAILURE EVENT REPORT: NAME = TRAC:2 Event Type = Equipment Failure Event Event Time = 22/Jan/2001 11:29:31 Probable Cause = Equipment Failure Specific Problems = 1088 - TRAC Card Failure Severity = Minor Notification Identifier = 29 Proposed Repair Actions = 13 - Insert and test the addressed card Originator = 27 Additional Words = H'0701 H'0003 H'0000 H'0000 H'0002 H'0002 H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff H'ffff Software Version = 02-06-01-01-03-00_01-01-19 END OF OUTPUT FOR JOB 11

Figure 1

Every fault occurrence from Local Terminal is related, at least, to one page of error description in this manual.

This manual is organized according to the PROBABLE CAUSE. Failure Events are grouped by Probable Cause. For every Probable Cause, different failure events are reported according to the Specific Problem field. In Annex A, for every TRAU Specific Problem, the associated Probable Cause is provided.
A30808-X3247-M440-1-7619 9

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

So, by taking into account these two elements the operator can determine the page of the error manual where the Failure Event being analyzed is described.

1045 - TRAC_DIAGNOSTIC_FAILURE
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: EQUIPMENT FAILURE Specific Problems: TRAC_DIAGNOSTIC_FAILURE Severity: <OPERATOR DEFINED> default: MINOR Proposed Repair Actions: NO ACTION Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: This error appears when the diagnostic performed on a TRAC without outstanding alarms fails. The TRAC is put disabled failed.
0102 (D)= for internal use only 0304 (D)= for internal use only 0507 (D)= for internal use only 0709 (D)= for internal use only 0910 (D)= for internal use only 1112 (D)= TRAC number 1314 (D)= 0xffff 1516 (D)= 0xffff 1718 (D)= 0xffff 1920 (D)= 0xffff 2122 (D)= 0xffff 2324 (D)= 0xffff 2526 (D)= 0xffff 2728 (D)= 0xffff 2930 (D)= 0xffff

Figure 2

Failure Event description example


Each field that appears in Figure 2 is explained below: FAILURE EVENT REPORT: <Class> <Class>:
10

<Object>

<Object Instance>

It determines unambiguously, togheter with the Error Id field the error.


A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

The following classes can report Failure Events: PCM_CIRCUIT EQUIPMENT LAPD_LINK TRANSCODER TSLA ENVATRAUE <Object>: PCMA PCMS TPWR BSMS TRAC LAPD TRAU TSLA ENVA 0 1 2 3 4 5 6 7 8 0 1 2 3 Presently not used 4 Presently not used 5

<Object Instance>: Object number (e.g. BSMS copy 0 or 1). Note that this is an internal organization for Failure Events grouping and the operator does not need further information to accomplish the analysis. Probable Cause It is an abbreviated sentence that describes the probable cause of the error.

Value for GSM12.11 specification:


EQUIPMENT FAILURE LINE INTERFACE FAILURE LOSS OF SYNCHRONIZATION DATABASE INCONSISTENCY INPUT PARAMETER OUT OF RANGE INVALID POINTER MESSAGE NOT EXPECTED MESSAGE OUT OF SEQUENCE SYSTEM CALL UNSUCCESSFUL TIMEOUT EXPIRED VARIABLE OUT OF RANGE WATCH DOG TIMER EXPIRED FAN FAILURE SYSTEM RESOURCES OVERLOAD LAPD LINK PROTOCOL FAILURE REMOTE ALARM INDICATION TRANSMISSION ERROR Value for ISO X.721 specification: CONFIGURATION OR CUSTOMIZATION ERROR CONGESTION CORRUPT DATA ENCLOSURE DOOR OPEN LOSS OF FRAME OUT OF MEMORY SOFTWARE ERROR 9 16 18 37 39 41 42 44 45 46 47 48 53 64 69 71 74 7 8 9 14 28 32 46 11

A30808-X3247-M440-1-7619

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

SW PROGRAM ABNORMALLY TERMINATED

47

(For further details see Annex A)

Specific Problem
This parameter identifies further refinements to the Probable Cause of the alarm according to the ITU-T Rec. X.733. In the Annex A, all the Specific Problems used by TRAU are provided with the Probable Cause of reference.

Event Type This parameter defines the alarm categories. Five basic categories of alarm are specified according to CCITT X.733. There are: COMMUNICATION FAILURE QUALITY OF SERVICE FAILURE PROCESSING FAILURE EQUIPMENT FAILURE ENVIRONMENTAL FAILURE Event Time This parameter identifies the time of detection or resolution of the fault and it is included in any Alarm Reporting notification. Severity According to CCITT X.733 the following severities can be reported When an error occurs: INDETERMINATE (not used in our system) CRITICAL MAJOR MINOR WARNING When an error ceases: CLEARED

In case of error ceased, please note that the message part that follows the Notification Identifier field is not printed by the Local Terminal.

Trend Indication The following Trend Indication values can be reported: LESS SEVERE NO CHANGE MORE SEVERE

12

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

The LESS SEVERE trend indication is printed if the associated severity for the concerned object, is less severe of those associated to previously reported Failure Events relevant to the same object and still active (i.e. no related error ceased message was generated). The NO CHANGE trend indication is printed if the associated severity for the concerned object, is the same as the highest of those associated to previously reported Failure Events relevant to the same object and still active (i.e. no related error ceased message was generated). The MORE SEVERE trend indication is printed if the associated severity for the concerned object, is more severe of those associated to previously reported Failure Events relevant to the same object and still active (i.e. no related error ceased message was generated). When the trend indication is Not Applicable (i.e. when the alarm is the first concerning an object) it is not reported by LMT and OMC. Notification Identifier According to the ITU-T X.733 specification the Notification Identifiers is unique across all notifications of a particular managed object throughout the time that correlation is significant. Correlated Notification According to the ITU-T X.733 specification this parameter, when present, contains a set of Notification identifiers and their associated managed object instance names. This set is defined to be the set of all notifications to which this notification is considered to be correlated. Thus, this parameter, included in the FER, identifies the notifications to which this notification is considered to be correlated. The Correlated Notifications parameter is present in the Failure Event Report only when it is retransmitted during the Alarm Alignment. Proposed Repair Actions According to the ITU-T X.733 specification, the Proposed Repair Actions parameter suggests a solution to the operator to repair the problem reported in the notification. In Annex B, all the Proposed Repair Actions used in the TRAU FER are provided. Additional Text According to CCITT X.733 this part, when present, allows a free form text description to be reported. At present the Additional Text will contain the associated string if any in the environmental alarm.

Originator It is an integer number that identifies the software module and the Task originating the Failure Event. In Annex C all the TRAU Originator are provided.

Additional Words 0102 2930 are hex values that are helpful for a detailed description of the error. This part is particularly useful to the software designer for analyzing the error cause and taking proper actions to solve the problem.
A30808-X3247-M440-1-7619 13

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

For each originator, under the Legend part of the Failure Event description, a concise description of the error and the meaning of the Additional Words are provided.

VERY IMPORTANT NOTE: Anyway, if the problem persists, i.e. the system or operator actions are unsuccessful, or occur periodically, the failure events must be collected and reported to the manufacturing company for analysis.

14

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1006-##1

3 GSM Probable Causes


3.1 Equipment Failure
3.1.1 1006 - PLL_FAILURE
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PLL_FAILURE Severity: Major Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 104 ALL1_PLL_ORIGINATOR Error description: The PLLALL1 interrupt is generated continuosly. This interrupt is originated by the arising of an hardware fault in the digital part of the PLL mounted on BSCI card. The PLL_ALL1 Interrupt Handler resets the BSCI card.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1006-##2

A30808-X3247-M440-1-7619

15

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1007-##1

3.1.2

1007 - BSCI_HW_FAULT

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSCI_HW_FAULT Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 111 BSMS Fault Detection Error description: An hardware fault occurred on BSCI Card. The BSMS is put in disabled failed state. The System starts the Automatic Diagnostic.
0102 (D)= Copy Number 0304 (D)= Identifier of the problem: BSCI_RAM_PARITY_ERROR BSCI_TIMING_LOSS FORCE_ALLPLL2_FAILED FORCE_RAM_PARITY_FAILED = = 2 8

= 55 = 57

FORCE_RAM_PROTECTION_FAILED = 58 BSCI_RAM_CORRUPTED 0506 (D)= Internal Originator: NMI_HANDLER_ORIGINATOR ALM_SPON_ORIGINATOR FAULT_DETECTION_BSMS TSK_TEST_BSMS = 101 = 102 = 111 = 120 = 85

0708 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR Task Entry Point (FP_SEG)

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR alarms

Internal Originator (0506 ) = FAULT_DETECTION_BSMS page# checksum error

Internal Originator (0506 ) = TSK_TEST_BSMS error info1

16

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

0910 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR Task Entry Point (FP_OFF)

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS error info2 1112 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR Task Logic Name

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS 0 1314 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._CS

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 1516 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._IP

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 1718 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._ES

A30808-X3247-M440-1-7619

17

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 1920 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._DS

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 2122 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._SI

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 2324 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._AX

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 2526 (D)= If Internal Originator (0506 ) = NMI_HANDLER_ORIGINATOR InterruptStatusSaveArea.SavedRegs._CX

If Internal Originator (0506 ) = ALM_SPON_ORIGINATOR Not Used

18

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

Internal Originator (0506 ) = FAULT_DETECTION_BSMS Not Used

Internal Originator (0506 ) = TSK_TEST_BSMS Not Used 2728 (D)= not used 2930 (D)= not used
##1007-##2

A30808-X3247-M440-1-7619

19

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1009-##1

3.1.3

1009 - TRAC_TIMING_LOSS

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_TIMING_LOSS Severity: Minor Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The TRAC card synchronization sources are not valid, and therefore the TRAC card is not able to perform its operations. The TRAC is put in disabled state.The System starts the Automatic Diagnostic procedure.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1009-##2

20

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1012-##1

3.1.4

1012 - PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 108 PROTECT_MEM_ORIGINATOR Error description: An illegal write attempt on a protected memory address has been trapped by the hardware. The protected memory regions include both the processor code area and the DBA data area. After the third illegal write attempt, the BSMS is set to disabled failed; the processor is put in halt mode and it does not restart by itself. The System starts the Automatic Diagnostic.
0102 (D)= Task Entry Point (FP_SEG) 0304 (D)= Task Entry Point (FP_OFF) 0506 (D)= Task Logic Name 0708 (D)= InterruptStatusSaveArea.SavedRegs._CS 0910 (D)= InterruptStatusSaveArea.SavedRegs._IP 1112 (D)= InterruptStatusSaveArea.SavedRegs._SS 1314 (D)= InterruptStatusSaveArea.SavedRegs._DS 1516 (D)= InterruptStatusSaveArea.SavedRegs._ES 1718 (D)= InterruptStatusSaveArea.SavedRegs._SP 1920 (D)= InterruptStatusSaveArea.SavedRegs._BP 2122 (D)= InterruptStatusSaveArea.SavedRegs._AX 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1012-##2

A30808-X3247-M440-1-7619

21

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1020-##1

3.1.5

1020 - PCMS_CIRCUIT_ALARM

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PCMS_CIRCUIT_ALARM Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: An Alarm on the circuit that manages the PCMS trunk on the BSCI card has arisen when either the trunk is NOT EQUIPPED or the BSCI belongs to the standby BSMS. It represents a BSCI HW fault. The PCM Device Controller Task informs BSMS Device Controller Task that reset the BSCI card. The BSCI remains in Firmware State. The BSMS is put disabled failed.The System starts the Automatic Diagnostic procedure.
0102 (D)= PCMS trunk alarmed: PCMS TRUNK A ='A' PCMS TRUNK B ='B' 0304 (D)= PCMS Alarm Type Identifier: ALM_INTERNAL ALM_LINE ALM_ERATE 0506 (D)= PCMS Alarm Identifier: BSCI V3 (DTIM-DTOM gate array(D)) mP address parity alarm = 01 mP data parity alarm = 02 DTIM clock slip alarm = 04 Timing Alarm = 08 RX Parity Alarm = 10 TX Parity Alarm = 40 BSCI V4 (FALC 54): AIS ALARM MLF ALARM RAI ALARM LFA ALARM LOS ALARM = 01 = 02 = 04 = 10 = 20 0x01 0x02 0x03

22

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

SYN ALARM SLIP ALARM

= 40 = 80

0708 (D)= If Alarm type (0304) is ALM_LINE: persisten alarm cause 0xaa

microinterruption alarm cause 0xcc

Otherwise: 0xffff 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1020-##2

A30808-X3247-M440-1-7619

23

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1021-##1

3.1.6

1021 - PCMA_CIRCUIT_ALARM

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: PCMA_CIRCUIT_ALARM Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: An Alarm on the circuit that manage the PCMA trunk on the MSCI card has occurred when either the PCMA is NOT EQUIPPED or the MSCI belongs to the standby BSMS. It represents a MSCI HW fault. The PCM Device Controller Task informs BSMS Device Controller Task that reset the MSCI card. The MSCI remains in Firmware State. The BSMS is put disabled failed. The System starts the Automatic Diagnostic procedure.
0102 (D)= PCMA line alarmed: PCMA Line 0 = 0 PCMA Line 1 = 01 PCMA Line 2 = 02 PCMA Line 3 = 03 0304 (D)= PCMA Alarm Type Identifier:: ALM_INTERNAL ALM_LINE ALM_ERATE 0506 (D)= PCMA Alarm Identifier: mP address parity alarm = 01 mP data parity alarm DTIM clock slip alarm = 04 Timing Alarm = 08 RX Parity Alarm = 10 TX Parity Alarm = 40 0708 (D)= If Alarm type Identifier (0304) is ALM_LINE 0xaa = 02 0x01 0x02 0x03

Otherwise: 0xffff 0910 (D)= not used

24

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1021-##2

A30808-X3247-M440-1-7619

25

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1042-##1

3.1.7

1042 - BSMS_DIAGNOSTIC_FAILURE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSMS_DIAGNOSTIC_FAILURE Severity: Major Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: This error appears when the diagnostic performed on the Standby BSMS without outstanding alarms fails. The BSMS is put disabled failed.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1042-##2

26

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1045-##1

3.1.8

1045 - TRAC_DIAGNOSTIC_FAILURE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_DIAGNOSTIC_FAILURE Severity: Minor Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: This error appears when the diagnostic performed on a TRAC without outstanding alarms fails. The TRAC is put disabled failed.
0102 (D)= for internal use only 0304 (D)= for internal use only 0506 (D)= for internal use only 0708 (D)= for internal use only 0910 (D)= for internal use only 1112 (D)= TRAC number 1314 (D)= 0xffff 1516 (D)= 0xffff 1718 (D)= 0xffff 1920 (D)= 0xffff 2122 (D)= 0xffff 2324 (D)= 0xffff 2526 (D)= 0xffff 2728 (D)= 0xffff 2930 (D)= 0xffff
##1045-##2

A30808-X3247-M440-1-7619

27

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1047-##1

3.1.9

1047 - TRAC_DIAGNOSTIC_ONLINE_FAILURE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_DIAGNOSTIC_ONLINE_FAILURE Severity: Minor Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: When this alarm occours, an automatic diagnostic starts. If diagnostic ends successfully, the TRAC card is put enabled. Vice versa, if diagnostic fails, the TRAC is put disabled failed.
0102 (D)= for internal use only 0304 (D)= for internal use only 0506 (D)= for internal use only 0708 (D)= for internal use only 0910 (D)= for internal use only 1112 (D)= TRAC number 1314 (D)= 0xffff 1516 (D)= On line diagnostic: card version: 0003 : TRACV3 0005 : TRACV5 1718 (D)= On line diagnostic: If TRACV3 board: Binary form: XXXX XXXX XXXX XXXX where X=0 DSP(i) Asub Loop OK X=1 DSP(i) Asub Loop Fault

If TRACV5 board: Binary form: XXXX XXXX XXXX XXXX where X=0 DSP Controller(i) Asub Loop OK X=1 DSP Controller(i) Asub Loop Fault 1920 (D)= On Line diagnostic: If TRACV3 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP(i) Asub Loop OK X=1 DSP(i) Asub Loop Fault

28

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

If TRACV5 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP Controller(i) Asub Loop OK X=1 DSP Controller(i) Asub Loop Fault 2122 (D)= On Line diagnostic: If TRACV3 board: Binary form: XXXX XXXX XXXX XXXX where X=0 DSP(i) A Loop OK X=1 DSP(i) A Loop Fault

If TRACV5 board: Binary form: XXXX XXXX XXXX XXXX where X=0 DSP Algorithmic(i) A Loop OK X=1 DSP Algorithmic(i) A Loop Fault 2324 (D)= On Line diagnostic: If TRACV3 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP(i) A Loop OK X=1 DSP(i) A Loop Fault

If TRACV5 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP Algorithmic(i) A Loop OK X=1 DSP Algorithmic(i) A Loop Fault 2526 (D)= 0xffff 2728 (D)= 0xffff 2930 (D)= 0xffff
##1047-##2

A30808-X3247-M440-1-7619

29

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1052-##1

3.1.10 1052 - TPWR_DIAGNOSTIC_FAILURE


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TPWR_DIAGNOSTIC_FAILURE Severity: Major Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 16 Power Supply Device Controller Error description: This error appears when the diagnostic performed on a TPWR without outstanding alarms fails. The TPWR is put disabled failed.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1052-##2

30

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1059-##1

3.1.11 1059 - MSCI_HW_FAULT


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_HW_FAULT Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: The MSCI has a hardware problem which is detailed in the Additional Info. If the error concerns the providing service BSMS a copy switch is performed. The BSMS copy related to the faulty MSCI is put disabled failed. The System starts the Automatic Diagnostic.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= not used 0708 (D)= error code 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1059-##2

A30808-X3247-M440-1-7619

31

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1074-##1

3.1.12 1074 - TPWR_FAULT


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TPWR_FAULT Severity: Major Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 16 Power Supply Device Controller Error description: The TPWR has an hardware failure, or the TPWR internal fault detection circuitry is faulty. If the fault is such that the active BSMS does not receive the power supply, a BSMS copy switch is performed.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1074-##2

32

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1077-##1

3.1.13 1077 - TRAC_HW_FAULT


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_HW_FAULT Severity: Minor Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The local TRAC fault detector test (WDT and TIMING) has failed. The TRAC state is set to disabled failed.The System starts the Automatic Diagnostic procedure.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1077-##2

A30808-X3247-M440-1-7619

33

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1078-##1

3.1.14 1078 - MSCI_SYNC_8KHZ_FAILED


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_SYNC_8KHZ_FAILED Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The 8KHz clock on MSCI card fails. This is the result of the MSCI Hardware fault related to this synchronism signal. The PCM device controller informs BSMS device controller that resets the BSCI and MSCI cards and puts the BSMS to disabled failed. The System starts the Automatic Diagnostic procedure.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1078-##2

34

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1079-##1

3.1.15 1079 - MSCI_DIGA_FAULTED


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_DIGA_FAULTED Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The gate array DIGA mounted on MSCI card has an internal hardware fault. The PCM device controller informs BSMS device controller that resets the BSCI and MSCI cards and puts the BSMS to disabled failed. The System starts the Automatic Diagnostic procedure.
0102 (D)= PCMA number (0-3) 0304 (D)= PCMA channel (1-31) 0506 (D)= loopback test inserted pattern 0708 (D)= fault cause 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1079-##2

A30808-X3247-M440-1-7619

35

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1081-##1

3.1.16 1081 - TRAC_FAIL_TO_LOAD


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_FAIL_TO_LOAD Severity: Minor Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: It was not possible to load the TRAC card after 5 attempts. This is due to an hardware failure. The TRAC is put disabled failed.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1081-##2

36

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1082-##1

3.1.17 1082 - FLASH_EPROM_NOT_VALID


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: FLASH_EPROM_NOT_VALID Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 40 CROSSCOPY_TSK, 48 RI Task Error description: An attempt to access to the Flash Eprom was failed, the Flash is damaged or in an inconsistent state. The System starts the Automatic Diagnostic procedure.
0102 (D)= kind of File system used: FAFS = 1 SLFS = 2 0304 (D)= File system function called: OPEN = 1 READ = 2 WRITE = 3 CLOSE = 4 ERASE = 5 SWCOMPL = 6 SWSTATUS = 7 FORMAT = 8 DIR = 9 DBREN = 10 0506 (D)= File System error number: WRITE ERROR = 100 (byte write,read back failed) VPP = 101 (VPP missing status reg. error) BWS = 102 (byte write status reg. error) VPP and BWS = 103ES = 104 (erase status reg. error) VPP and ES = 105ES and BWS = 106 VPP, BWS and ES = 107 OPERATION TIMEOUT = 200 ERASE ERROR = 300 COMMAND SEQUENCE ERROR = 400

A30808-X3247-M440-1-7619

37

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

0708 (D)= file name first letter (ASCII code) 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1082-##2

38

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1086-##1

3.1.18 1086 - TRAC_LINK_FAILURE


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_LINK_FAILURE Severity: Minor Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The link to the TRAC card could not be established, therefore it is not possible to send or receive messages from the given TRAC. This is probably due to a hardware failure on the TRAC card. The System starts the Automatic Diagnostic procedure.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1086-##2

A30808-X3247-M440-1-7619

39

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1088-##1

3.1.19 1088 - TRAC_CARD_FAILURE


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: TRAC_CARD_FAILURE Severity: Minor Proposed Repair Actions: Insert and test the addressed card Insert the addressed card in the frame. Then, test it. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The TRAC card is extracted from the TRAU shelf.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1088-##2

40

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1089-##1

3.1.20 1089 - DSP_FAIL_TO_LOAD


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: DSP_FAIL_TO_LOAD Severity: Minor Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: After 5 attempts to load the TRAC controller software and the DSP software, one or more DSPs has never answered to the TRAC controller. The traffic channels of the DSPs which failed the keepalive are probably failed. The error can be caused DSP code or by an hardware failure on the DSPs. The System set the TRAC State to faulty.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1089-##2

A30808-X3247-M440-1-7619

41

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1100-##1

3.1.21 1100 - BSCI_CARD_FAILURE


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSCI_CARD_FAILURE Severity: Major Proposed Repair Actions: Insert and test the addressed card Insert the addressed card in the frame. Then, test it. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 122 BSCI Audit Error description: A BSCI card without outstanding alarms has been extracted.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1100-##2

42

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1104-##1

3.1.22 1104 - BSCI_KEEP_ALIVE_ALARM


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: BSCI_KEEP_ALIVE_ALARM Severity: Major Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler, 38 Status Manager Notify Handler Error description: The BSCI card of the standby BSMS does not respond to the providing service BSMS keepalive requests. The BSMS copy is considered disabled.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1104-##2

A30808-X3247-M440-1-7619

43

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1105-##1

3.1.23 1105 - MSCI_KEEP_ALIVE_ALARM


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: MSCI_KEEP_ALIVE_ALARM Severity: Major Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: The MSCI card of the indicated BSMS does not respond to the BSCI keepalive requests. If the error concerns the providing service BSMS a copy switch is performed. The related BSMS goes to disabled failed state.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1105-##2

44

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1106-##1

3.1.24 1106 - INCONSISTENT_STATUS


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Equipment Failure Specific Problems: INCONSISTENT_STATUS Severity: Major Proposed Repair Actions: See the automatic diagnostic test result Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: The BSCI is not properly configured. If the error concerns the providing services BSMS a copy switch is performed. The related BSMS goes to disabled failed state . The System starts the Automatic Diagnostic procedure.
0102 (D)= Wrong polling configuration = 0 Wrong FPGA configuration = 1 0304 (D)= If 0102 = 1 Register G value 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1106-##2

A30808-X3247-M440-1-7619

45

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##11-##1

3.2 Line Interface Failure


3.2.1 11 - LOSS_OF_SIGNAL
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: LOSS_OF_SIGNAL Severity: Major Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The line interface component (DTOM or FALC) does not receive the signal on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disable state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 =0 = 0x0001 = 0x0002 = 0x0003

PCMS trunk A = 0x000a PCMS trunk B = 0x000b 0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm

Alarm due to microinterruptions = 0x00cc 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used

46

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##11-##2

A30808-X3247-M440-1-7619

47

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##12-##1

3.2.2

12 - AIS_ALARM

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: AIS_ALARM Severity: Major Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: An Ais alarm has occurred on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. This means that PCM stream is composed by bits that are all 1. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disable state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 PCMS trunk A PCMS trunk B =0 = 0x0001 = 0x0002 = 0x0003 = 0x000a = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used

48

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##12-##2

A30808-X3247-M440-1-7619

49

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##18-##1

3.2.3

18 - LOSS_OF_SIGNAL_ON_LINK_A

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: LOSS_OF_SIGNAL_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The line interface component (DTOM or FALC) does not receive the signal on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm

Alarm due to microinterruptions = 0x00cc 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used

50

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

2930 (D)= not used


##18-##2

A30808-X3247-M440-1-7619

51

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##19-##1

3.2.4

19 - LOSS_OF_SIGNAL_ON_LINK_B

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: LOSS_OF_SIGNAL_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The line interface component (DTOM or FALC) does not receive the signal on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm

Alarm due to microinterruptions = 0x00cc 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used

52

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

2930 (D)= not used


##19-##2

A30808-X3247-M440-1-7619

53

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##20-##1

3.2.5

20 - AIS_ALARM_ON_LINK_A

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: AIS_ALARM_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Ais alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that PCM stream is composed by bits that are all 1. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used

54

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

2930 (D)= not used


##20-##2

A30808-X3247-M440-1-7619

55

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##21-##1

3.2.6

21 - AIS_ALARM_ON_LINK_B

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Line Interface Failure Specific Problems: AIS_ALARM_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: An Ais alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that PCM stream is composed by bits that are all 1. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used

56

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

2930 (D)= not used


##21-##2

A30808-X3247-M440-1-7619

57

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1097-##1

3.3 Loss of Synchronisation


3.3.1 1097 - BAD_PLL_INPUT_SYNCHRONISATION
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss of Synchronisation Specific Problems: BAD_PLL_INPUT_SYNCHRONISATION Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 107 ALL2_PLL Interrupt Handler Error description: This alarm arises when the PLL circuit is not able to lock itself to the input PCM synchronizing line because this line has a frequency deviation or excessive Jitter. The PCM synchronizing line has changed if other PCM (PCMA or PCMS) is available. Otherwise the PLL is forced into FREE_RUNNING state.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1097-##2

58

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1019-##1

3.4 Database Inconsistency


3.4.1 1019 - INVALID_DATABASE_WARNING
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: INVALID_DATABASE_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler, 48 RI Task Error description: A call to a Database Services function has failed.
0102 (D)= Source code line 0304 (D)= trac staus 0506 (D)= waiting 0708 (D)= flag 0910 (D)= diag state 1112 (D)= trac instance 1314 (D)= trac:0 subtable 1516 (D)= trac:1 subtable 1718 (D)= trac:2 subtable 1920 (D)= trac:3 subtable 2122 (D)= trac:4 subtable 2324 (D)= trac:5 subtable 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1019-##2

A30808-X3247-M440-1-7619

59

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1023-##1

3.4.2

1023 - TRAC_DBA_REFUSED

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: TRAC_DBA_REFUSED Severity: Minor Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The TRAC software has not accepted the transcoder matrix sent by the BSCI after a bringup or reloading. The cause can be a transcoder matrix with a wrong format. The TRAC card is put disabled failed.
0102 (D)= for internal use only 0304 (D)= for internal use only 0506 (D)= for internal use only 0708 (D)= for internal use only 0910 (D)= for internal use only 1112 (D)= transcoder matrix index [0..5, FF] 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1023-##2

60

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1091-##1

3.4.3

1091 - DATABASE_INCONSISTENCY_BRINGUP

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: DATABASE_INCONSISTENCY_BRINGUP Severity: Major Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: A database inconsistency or corruption has been discovered. The system automatically restores a default database going temporarily out of service.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= bsms current state 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1091-##2

A30808-X3247-M440-1-7619

61

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1102-##1

3.4.4

1102 - PROBABLE_DATABASE_INCONSISTENCY

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Database Inconsistency Specific Problems: PROBABLE_DATABASE_INCONSISTENCY Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: A probable database inconsistency or corruption has been found on the standby BSMS. The involved BSMS copy is reset and reloaded. Its database is retrieved, through a crosscopy procedure, from the providing service BSMS.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= bsms curr state 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1102-##2

62

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1015-##1

3.5 Input Parameter out of Range


3.5.1 1015 - INPUT_PARAMETER_OUT_OF_RANGE_WARNING
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Input Parameter out of Range Specific Problems: INPUT_PARAMETER_OUT_OF_RANGE_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 18 IPC_COLLECTOR_TSK, 23 Data Base, 24 SM_COMM_TSK, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 38 Status Manager Notify Handler, 40 CROSSCOPY_TSK, 42 BDGDMPEPR_TSK Error description: A call with wrong parameters was issued. Case of originator 29
0102 (D)= code statement number 0304 (D)= error type or parameter value 0506 (D)= link (card) identifier: 00-05 TRAC 0-5 0708 (D)= processor identifier(meaningful for TRAC cards): 00 Trac controller 01 Dsp 0910 (D)= last transmitted packet 1112 (D)= FSM state value 1314 (D)= source system of received message 1516 (D)= signal type of received message 1718 (D)= signal subtype of received message 1920 (D)= transmitted bytes 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1015-##2

A30808-X3247-M440-1-7619

63

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1114-##1

3.6 Invalid Pointer


3.6.1 1114 - INVALID_POINTER_WARNING
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Invalid Pointer Specific Problems: INVALID_POINTER_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: An invalid pointer has been detected by the RTE+ operating system.
0102 (D)= 000e: a bad timing cell pointer has been detected 000f: a bad suspended link pointer address has been detected 0010: an undeclared function pointer has been detected 0015: a null pointer has been detected 0016: a scheduler error has been detected 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1114-##2

64

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1014-##1

3.7 Message not Expected


3.7.1 1014 - UNEXPECTED_MESSAGE
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: UNEXPECTED_MESSAGE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 16 Power Supply Device Controller, 19 IPC Dispatcher, 21 LMT_IO_DLM_TSK, 23 Data Base, 24 SM_COMM_TSK, 25 Alarm Reporting, 26 BSMS Device Handler, 27 TRAC Device Handler, 28 DOWNLOAD_TSK, 38 Status Manager Notify Handler, 39 PCM Device Controller Task, 40 CROSSCOPY_TSK, 42 BDGDMPEPR_TSK, 47 DC ENVA TSK, 48 RI Task, 134 TDGDM_PI_PROCESS, 135 TDGDMPI_STBY, 145 FDGDM_OUTPUT Error description: This error is displayed when an Area receives a message not admitted. The possible additional information are not relevant.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1014-##2

A30808-X3247-M440-1-7619

65

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1044-##1

3.7.2

1044 - INVALID_MESSAGE_DATA

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: INVALID_MESSAGE_DATA Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 18 IPC_COLLECTOR_TSK, 19 IPC Dispatcher, 20 IPC Link Maneger, 23 Data Base, 25 Alarm Reporting, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 32 BSC_LINKMNGR_TSK, 38 Status Manager Notify Handler Error description: In case of Originator 29,this error is displayed when an Area receives a message with wrong data.
0102 (D)= code statement number 0304 (D)= error type or parameter value 0506 (D)= not meaningful 0708 (D)= not meaningful 0910 (D)= not meaningful 1112 (D)= not meaningful 1314 (D)= source system of received message 1516 (D)= signal type of received message 1718 (D)= signal subtype of received message 1920 (D)= not meaningful 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1044-##2

66

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1048-##1

3.7.3

1048 - INVALID_RTE_HEADER_FIELD_VALUE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: INVALID_RTE_HEADER_FIELD_VALUE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 28 DOWNLOAD_TSK, 32 BSC_LINKMNGR_TSK, 41 Sync Device Handler Error description: A message with an incorrect/unexpected RTE header field value has been received. In case of Originator = 28, the Download is aborted. Case of Originator = 32
0102 (D)= Source mailbox of received message 0304 (D)= Signal type of received message 0506 (D)= Signal subtype of received message 0708 (D)= Data lenght of received message 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1048-##2

A30808-X3247-M440-1-7619

67

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1060-##1

3.7.4

1060 - MSCI_SW_ERROR

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: MSCI_SW_ERROR Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: MSCI has received an invalid message.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= 0xff 0708 (D)= type of error 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1060-##2

68

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1080-##1

3.7.5

1080 - TRAC_UNEXPECTED_MESSAGE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message not Expected Specific Problems: TRAC_UNEXPECTED_MESSAGE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: An unexpected message has been received from the TRAC card.
0102 (D)= Trac card number 0304 (D)= Source system 0506 (D)= Destination system 0708 (D)= signal type 0910 (D)= signal subtype 1112 (D)= datalen 1314 (D)= TRAC D.H. internal state 1516 (D)= message data 1718 (D)= message data 1920 (D)= message data 2122 (D)= message data 2324 (D)= message data 2526 (D)= message data 2728 (D)= message data 2930 (D)= message data
##1080-##2

A30808-X3247-M440-1-7619

69

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1033-##1

3.8 Message Out of Sequence


3.8.1 1033 - MESSAGE_OUT_OF_SEQUENCE_WARNING
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Message Out of Sequence Specific Problems: MESSAGE_OUT_OF_SEQUENCE_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 32 BSC_LINKMNGR_TSK, 35 Alignment Service Task, 38 Status Manager Notify Handler Error description: The message received is not the expected one
0102 (D)= Originator 32: for internal use only Originator 35 : for internal use only ('C' statement number) Originator 38: object class - possible values: 0x84 = sAsubEquipment 0x86 = sAsub_trauSyncronization the other possible values are for internal use only 0304 (D)= Originator 32: for internal use only Originator 35: for internal use only (internal FSM state) Originator 38: meaningfull only if 0102 = 0x84 - possible value: 0x01 = TRAC. 0506 (D)= Originator 32: for internal use only Originator 35: for internal use only (source system of received message) Originator 38: meaningfull only if 0102 = 0x84 - possible values : TRAC instance. 0708 (D)= Originator 32: for internal use only Originator 35: for internal use only (source mailbox of received message) Originator 38: for internal use only (internal FSM state). 0910 (D)= Originator 32: for internal use only Originator 35: for internal use only (signal type of received message) Originator 38: for internal use only (internal FSM event). 1112 (D)= Originator 32 for internal use only Originator 35: for internal use only (signal subtype of received message) 1314 (D)= Originator 35: for internal use only (data length of received message) 1516 (D)= not used 1718 (D)= not used

70

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 28 DOWNLOAD_TSK Error description: The packet received is not the expected one. The Download is aborted.
0102 (D)= Expected LDS packet number 0304 (D)= Received LDS packet number 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1033-##2

A30808-X3247-M440-1-7619

71

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1024-##1

3.9 System Call Unsuccessful


3.9.1 1024 - SYSTEM_CALL_UNSUCCESSFUL_WARNING
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: SYSTEM_CALL_UNSUCCESSFUL_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 35 Alignment Service Task Error description:
0102 (D)= code statement number 0304 (D)= FSM state value 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 16 Power Supply Device Controller, 18 IPC_COLLECTOR_TSK, 19 IPC Dispatcher, 20 IPC Link Maneger, 23 Data Base, 24 SM_COMM_TSK, 25 Alarm Reporting, 26 BSMS Device Handler, 27 TRAC Device Handler, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 32 BSC_LINKMNGR_TSK, 34 RAM CRC, 35 Alignment Service Task, 38 Status Manager Notify Handler, 39 PCM Device Controller Task, 40 CROSSCOPY_TSK, 41 Sync Device Handler, 42 BDGDMPEPR_TSK, 48 RI Task, 100 Error Collector, 102 Spontaneous Alarm, 111 BSMS Fault Detection, 116 WDT Fault Detection, 120 Test BSMS, 130 FDGDM_DIAG_ACTIVATION0, 131 FDGDM_DIAG_ACTIVATION1, 132 SEND_TEST_IN_PROGRESS, 133 SEND_PHASE_RESULT, 138 FDGDM_SYNC_DEVICE0, 139 FDGDM_SYNC_DEVICE1, 140 STOP_TEST_RUNNING, 141 SEND_DSC_TO_SM, 142 UPDATE_BSCI_STBY, 143 SEND_OUTPUT_RESULT, 144 SEND_DUMMY_RESULT, 146 FDGHD_BSMS, 147 72 A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

FDGHD_TRAC, 148 FDGHD_TPWR, 149 MSCI_DIAG_CONTROLLER, 150 TDGHD_BSMS_STBY Error description: A system call was issued without success. Following Additional Words are not always used. Case of Originator = 29
0102 (D)= code statement number 0304 (D)= error type or parameter value 0506 (D)= link (card) identifier: 06 MSCI 00 - 05 TRAC 0-5

0708 (D)= processor identifier (meaningful for TRAC cards) 00 01 Trac controller Dsp

0910 (D)= last transmitted packet 1112 (D)= FSM state value 1314 (D)= source system of received message 1516 (D)= signal type of received message 1718 (D)= signal subtype of received message 1920 (D)= transmitted bytes 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 46 EVENT_LOG_TSK Error description: This error occours when Event Log task tries to flush the log buffer.The log is however appended and the log is flushed the next time the task runs.
0102 (D)= error code line 0304 (D)= signal subtype 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1024-##2

A30808-X3247-M440-1-7619

73

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1028-##1

3.9.2

1028 - FUNCTION_CALL_UNSUCCESSFUL

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: FUNCTION_CALL_UNSUCCESSFUL Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 19 IPC Dispatcher Error description: Interprocessor Communication internal error (dl_receive() failure)
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 24 SM_COMM_TSK Error description: Unable to get an attribute value from the system, that refueses the Get Attribute command.
0102 (D)= attribute identifier: E_AI_DIRECTORY_LIST = 0x85 E_AI_RUNNING_FILES = 0x8D E_AI_TRAU_SW_LOAD_HEADER = 0x94 E_AI_LMT_SESSION = 0xC6 E_AI_LMT_LOGON_TIME = 0xC7

74

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

E_AI_LMT_USR_ACCESS_LEVEL = 0xC8 E_AI_LMT_USR_NAME = 0xC9 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 39 PCM Device Controller Task Error description: Unable to get information from database (fomdb_read_table() failure)
0102 (D)= signal_type INTRAPROCESSOR = 0xFFFF 0304 (D)= signal_subtype COMDB_DH_SET_PCMS = 0x0715 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 23 Data Base, 48 RI Task Error description:

A30808-X3247-M440-1-7619

75

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

Unable to send an internal message. In the following cases: 0102 = INTRAPROCESSOR 0xffff 0304 = COMDB_LOAD_MSCI_DB 0x712 COMDB_DH_SET_PCMS 0x715 the system reset is performed.
0102 (D)= signal_type 0304 (D)= signal_subtype 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1028-##2

76

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1066-##1

3.9.3

1066 - MESSAGE_NOT_SENT

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: MESSAGE_NOT_SENT Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 21 LMT_IO_DLM_TSK, 32 BSC_LINKMNGR_TSK Error description: One or more messages hasn't been sent. In general a previous system call was failed.
0102 (D)= RTE Header field, Operating System Pool Type Memory . 0304 (D)= RTE Header field, Source System. 0506 (D)= RTE Header field, Destination System. 0708 (D)= RTE Header field, Source Mailbox. 0910 (D)= RTE Header field, Destination Mailbox. 1112 (D)= RTE Header field, Signal Type. 1314 (D)= RTE Header field, Signal SubType. 1516 (D)= RTE Header field, Data Length. 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 24 SM_COMM_TSK, 38 Status Manager Notify Handler Error description: One or more messages hasn't been sent. In general a previous system call was failed.
0102 (D)= Sygnal Subtype of the MSG Lost 0304 (D)= Object Type. 0506 (D)= Object Instance. 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used

A30808-X3247-M440-1-7619

77

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1066-##2

78

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1067-##1

3.9.4

1067 - INVALID_DB_CALL

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: INVALID_DB_CALL Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base Error description: A wrong access to TRAU Database has been performed. The access to Database is refused.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1067-##2

A30808-X3247-M440-1-7619

79

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1096-##1

3.9.5

1096 - SYSTEM_CALL_UNSUCCESSFUL_MINOR

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Call Unsuccessful Specific Problems: SYSTEM_CALL_UNSUCCESSFUL_MINOR Severity: Major Proposed Repair Actions: Test the card if it is a standby one If the addressed card is the StandBy one, test it. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: Unsuccessful function call. This error implies a serious system malfunction. The BSMS is put in disabled failed state by the system.
0102 (D)= error code 0304 (D)= signal type 0506 (D)= signal subtype 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1096-##2

80

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1037-##1

3.10 Timeout Expired


3.10.1 1037 - TIMEOUT_EXPIRED_WARNING
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: TIMEOUT_EXPIRED_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 151 BSCI FW Error description: BSCI FW notifies that BSCI flash memory eeprom is empty or the stand-by card is extracted. SW version is not avaiable because FW doesn't have the acknowledge.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 23 Data Base, 26 BSMS Device Handler, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 38 Status Manager Notify Handler, 40 CROSSCOPY_TSK, 46 EVENT_LOG_TSK, 151 BSCI FW Error description: Case of Originator = 23 Timeout expiring while waiting a message.
0102 (D)= not used

A30808-X3247-M440-1-7619

81

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 26 BSMS Device Handler Error description: Timeout expiring while waiting a message.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 38 Status Manager Notify Handler Error description: Timeout expiring while waiting a message.
0102 (D)= message Id. 0304 (D)= FSM state 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used

82

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 46 EVENT_LOG_TSK Error description: Timeout expiring while waiting a message.


0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 40 CROSSCOPY_TSK Error description: Timeout expiring while waiting a message. Crosscopy aborted by the system.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used

A30808-X3247-M440-1-7619

83

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

2930 (D)= not used

Originator: 28 DOWNLOAD_TSK Error description: Timeout expiring while waiting a message. Downloading aborted by the system.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 29 PERIPH_LOAD_TSK Error description: Timeout expiring while waiting a message. Peripheral loading aborted by the system.
0102 (D)= code statement number 0304 (D)= error type or parameter value 0506 (D)= link (card) identifier: 00-05 TRAC 0-5 06 MSCI 0708 (D)= processor identifier(meaningful for TRAC cards): 00 Trac controller 01 Dsp 0910 (D)= last transmitted packet 1112 (D)= FSM state value 1314 (D)= source system of received message 1516 (D)= signal type of received message 1718 (D)= signal subtype of received message 1920 (D)= transmitted bytes 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1037-##2

84

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1075-##1

3.10.2 1075 - TRAC_KEEP_ALIVE_ALARM


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: TRAC_KEEP_ALIVE_ALARM Severity: Minor Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The TRAC card has not answered within the answer time to a previsouly sent message. The TRAC is put in disabled failed state.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1075-##2

A30808-X3247-M440-1-7619

85

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1087-##1

3.10.3 1087 - DSP_TSYNC_EXPIRED


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: DSP_TSYNC_EXPIRED Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: A TSYNC timer expired for one ASUB time slot. This means that, for a time interval equal or greater than the TSYNC (or TTRAU) value, on the specified ASUB subtimeslot no idle pattern neither TRAU frames have been detected. This happens when the ASUB line is disconnected or in case of network or BTS failure. The notification comes from the DSPs on the TRAC cards. When the error arises on the same Asub time slot with a frequency of about 4 minutes two cases are possible: - the Asub line is disconnected or unstable; - a fault of one or more receivers of the TRAC board is detected.
0102 (D)= for internal use only 0304 (D)= for internal use only 0506 (D)= for internal use only 0708 (D)= for internal use only 0910 (D)= for internal use only 1112 (D)= The subtimeslot number (in the range 0..127) on the ASUB on which the TSYNC expired. 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1087-##2

86

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1090-##1

3.10.4 1090 - DSP_KEEP_ALIVE_ALARM


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Timeout Expired Specific Problems: DSP_KEEP_ALIVE_ALARM Severity: Minor Proposed Repair Actions: Replace the addressed card Replace the addressed card. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: As a result of the continous keepalive polling of the DSPs status on the TRAC card, one or more DSPs has ceased answering to the TRAC controller. The traffic channels of the DSPs which failed the keepalive are probably failed. The error can be caused by a software error on the DSP code or by an hardware failure on the DSPs; the exact cause can be found only after reloading the TRAC. When this error occurs, two cases must be distinguish: 1) If BSMS Standby copy has Operational State equal to ENABLE and Administrative State equal to UNLOCKED the behavior is as follow: An automatic diagnostic starts, if it ends successful the TRAC is put in Operational State ENABLE, vice versa, if the diagnostic fails, the TRAC is put in Operational State DISABLE. 2) If BSMS Standby copy has Operational State equal to DISABLE and/or Administrative State equal to LOCKED, the behavior is as follow: An automatic diagnostic starts, and the test phase "BSCILoopTest" is skipped; for this reason it isn't possible to detect the alarm. If further DSP_KEEPALIVE_ALARM occurs within 15 minutes, another automatic diagnostic starts; If the last diagnostic ends successful the TRAC is put in Operational State ENABLE, vice versa, if the second diagnostic ends unsuccessful, the alarm 'DSP_FAIL_TO_LOAD' is sent and the TRAC is put in Operational State DISABLE. Note: the following additional words are meaningful only if the trac is Enabled.
0102 (D)= If TRACV1 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP(i) general failure X=1 DSP(i) OK

If TRACV3 board:Binary form: XXXX XXXX XXXX XXXX where X=0 DSP(i) general failure

A30808-X3247-M440-1-7619

87

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

X=1 DSP(i) OK

If TRACV5 board: Binary form: XXXY XXXY XXXY XXXY where Y=0 DSP Controller(j) general failure Y=1 DSP Controller(j) OK X=0 DSP Algorithmic(i) general failure X=1 DSP Algorithmic(i) OK and (0<=j<=3, 0<=i<=11) If TRACV7 board: Binary form:1111 1111 1111 11XX where X=0 DSP(i) general failure X=1 DSP(i) OK 0<=i<=1 0304 (D)= If TRACV1 board: Binary form: 1111 1111 1111 1111

If TRACV3 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP(i) general failure X=1 DSP(i) OK

If TRACV5 board: Binary form: 1111 1111 1111 1111

If TRACV7 board: Binary form: 1111 1111 1111 1111 0506 (D)= card version: 0001 : TRACV1 0003 : TRACV3 0005 : TRACV5 0007: TRACV7 0708 (D)= If TRACV1 board: Binary form: 1111 1111 XXXX XXXX where X=0 DSP(i) Keep_Alive response failure X=1 DSP(i) Keep_Alive response OK

If TRACV3 board: Binary form: XXXX XXXX XXXX XXXX where X=0 DSP(i) Keep_Alive response failure X=1 DSP(i) Keep_Alive response OK

If TRACV5 board: Binary form: XXXY XXXY XXXY XXXY where Y=0 DSP Controller(j) Keep_Alive response failure Y=1 DSP Controller(j) Keep_Alive response OK X=0 DSP Algorithmic(i) Communication failure X=1 DSP Algorithmic(i) Communication OK and (0<=j<=3, 0<=i<=11) If TRACV7 board:

88

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

Binary form: 1111 1111 1111 11XX where X=0 DSP(i) response failure (no response received from DSP) X=1 DSP(i) DSP OK and 0<=i<=1 0910 (D)= If TRACV1 board: Binary form: 1111 1111 1111 1111

If TRACV3 board:Binary form: 1111 1111 XXXX XXXX where X=0 DSP(i) Keep_Alive response failure X=1 DSP(i) Keep_Alive response OK

If TRACV5 board: Binary form: 1111 1111 1111 1111 If TRACV7 board: Binary form: 1111 1111 1111 1111 1112 (D)= If TRACV1 board: Binary form: 1111 1111 XXXX XXXX where X=1 DSP(i) Check_sum failure X=0 DSP(i) Check_sum OK

If TRACV3 board: Binary form: XXXX XXXX XXXX XXXX where X=1 DSP(i) Check_sum failure X=0 DSP(i) Check_sum OK

If TRACV5 board:Binary form: XXXY XXXY XXXY XXXY where Y=1 DSP Controller(j) Check_sum failure Y=0 DSP Controller(j) Check_sum OK X=1 DSP Algorithmic(i) Check_sum failure X=0 DSP Algorithmic(i) Check_sum OK and (0<=j<=3, 0<=i<=11)

If TRACV7 board:Binary form: 0000 0000 0000 XYXY where Y=0 DSP(i) Data Memory Checksum OK Y=1 DSP(i) Data Memory Checksum Error X=0 DSP(i) Code Memory Checksum OK X=1 DSP(i) Code Memory Checksum Error 1314 (D)= If TRACV1 board: Binary form: 1111 1111 1111 1111

If TRACV3 board: Binary form: 1111 1111 XXXX XXXX where X=1 DSP(i) Check_sum failure X=0 DSP(i) Check_sum OK

If TRACV5 board: Binary form: 1111 1111 1111 1111

A30808-X3247-M440-1-7619

89

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

If TRACV7 board: Binary form: 0000 0000 0000 0000 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1090-##2

90

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1029-##1

3.11 Variable Out of Range


3.11.1 1029 - VARIABLE_OUT_OF_RANGE
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Variable Out of Range Specific Problems: VARIABLE_OUT_OF_RANGE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler, 48 RI Task, 136 FDGDM_IRAS Error description: Case 27: A message containing an invalid field value was received by the TRAC Device Controller, or an inconsistent internal TRAC Device Controller state has been detected. Case 48, 136: A message containing an invalid field value was received.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1029-##2

A30808-X3247-M440-1-7619

91

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1003-##1

3.12 Watch Dog Timer Expired


3.12.1 1003 - TRAC_WDT_TIMEOUT
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Watch Dog Timer Expired Specific Problems: TRAC_WDT_TIMEOUT Severity: Minor Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: The TRAC card watchdog timer has expired, probably due to a software error on the TRAC controller software. The TRAC Device Controller attempts to reset the TRAC card which caused the error, then tries to reload it with software. The TRAC card goes to disabled faulty state until the link toward it is established again.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1003-##2

92

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1004-##1

3.12.2 1004 - BSCI_WDT_TIMEOUT


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Watch Dog Timer Expired Specific Problems: BSCI_WDT_TIMEOUT Severity: Major Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 101 NMI Interrupt Handler Error description: A Watch Dog Timer has expired on BSCI card. When the observed value is 3 the NMI Interrupt Handler resets the BSCI card.
0102 (D)= Object Instance BSMS copy: 0 BSMS copy: 1 = 00 = 01

0304 (D)= Error Id (BSCI_WDT_TIMEOUT) 0506 (D)= Originator Id (NMI Interrupt Handler) 0708 (D)= wdt occurrence counter 0910 (D)= Task Entry Point Segment value 1112 (D)= Task Entry Point Offset value 1314 (D)= Task Logic Name value 1516 (D)= Code Segment value 1718 (D)= Instruction Ponter value 1920 (D)= Stack Segment value 2122 (D)= Data Segment value 2324 (D)= Extra Segment value 2526 (D)= Stack Pointer value 2728 (D)= Base Pointer value 2930 (D)= AX
##1004-##2

A30808-X3247-M440-1-7619

93

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1005-##1

3.12.3 1005 - BSCI_WDT_WARNING


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Watch Dog Timer Expired Specific Problems: BSCI_WDT_WARNING Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 101 NMI Interrupt Handler Error description: A Watch Dog Timer has expired on BSCI card.
0102 (D)= Object Instance BSMS copy: 0 BSMS copy: 1 = 00 = 01

0304 (D)= Error Id (BSCI_WDT_WARNING) 0506 (D)= Originator Id (NMI Interrupt Handler) 0708 (D)= wdt occurrence counter 0910 (D)= Task Entry Point Segment value 1112 (D)= Task Entry Point Offset value 1314 (D)= Task Logic Name value 1516 (D)= Code Segment value 1718 (D)= Instruction Pointer value 1920 (D)= Stack Segment value 2122 (D)= Data Segment value 2324 (D)= Extra Segment value 2526 (D)= Stack Pointer value 2728 (D)= Base Pointer valu 2930 (D)= AX
##1005-##2

94

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##5002-##1

3.13 FAN Failure


3.13.1 5002 - FAN_ALARM
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: ENVIRONMENTAL FAILURE EVENT Probable Cause: FAN Failure Specific Problems: FAN_ALARM Severity: Critical Proposed Repair Actions: See the foreseen operating company repair action Environmental alarm. The repair action is defined by the operating company. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 47 DC ENVA TSK Error description: The alarm persistency sensed by the Scan Work Function which polls the ENVA sense point on the BSCI card has reached the threshold fixed by the operator.
0102 (D)= for internal use only 0304 (D)= for internal use only 0506 (D)= ENVA instance = 0 0708 (D)= Threshold 0910 (D)= Counter 1112 (D)= Name of ENVA 1314 (D)= Scan Work Function FLAG: Disabled = 0 Enabled = 1 1516 (D)= Interface logic Negative logic = 0 Positive logic = 1 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##5002-##2

A30808-X3247-M440-1-7619

95

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1115-##1

3.14 System Resources Overload


3.14.1 1115 - UNABLE_TO_RUN_TEST
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: System Resources Overload Specific Problems: UNABLE_TO_RUN_TEST Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 137 Activate Test Error description: The test cannot be performed due to insufficient system resources. That particular test ends without result.
0102 (D)= Test instance 0304 (D)= Nack cause. Possible values: 0x1E = E_NC_PHISICAL_CONFIGURATION_CANNOT_BE_PERFORMED 0X1F = E_NC_TEST_NOT_INITIATED 0X97 = E_NC_MOT_NOT_LOCKED 0XC7 = E_NC_INVALID_WORKING_PHASE 0506 (D)= MOT mnemonic 0708 (D)= MOT address[0] 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1115-##2

96

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##2001-##1

3.15 LAPD Link Protocol Failure


3.15.1 2001 - ASUB_TRANSIENT_FAILURE
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: LAPD Link Protocol Failure Specific Problems: ASUB_TRANSIENT_FAILURE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 32 BSC_LINKMNGR_TSK Error description: LAPD layer 2 manager on TRAU side has found and recovered a failure. There is the possibility of messages loss in the link between TRAU and BSC.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##2001-##2

A30808-X3247-M440-1-7619

97

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##2003-##1

3.15.2 2003 - LPDL_LINK_DOWN


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: LAPD Link Protocol Failure Specific Problems: LPDL_LINK_DOWN Severity: Critical Proposed Repair Actions: Check the LAPD parameters on both side Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 32 BSC_LINKMNGR_TSK Error description: This error is generated in the following cases: - The timeslot used for LAPD on TRAU is not the same set on BSC - TRAU becames free running due to the loss of the syncronism coming from BSC - reception of a Layer 3 release indication - reception of a Layer 3 error The LAPD goes to disabled.
0102 (D)= Link status : 1 = established 0 = not established 0304 (D)= for internal use only 0506 (D)= TEI number 0708 (D)= Retry connection : 1 = LAPD connection request has been performed 0910 (D)= for internal use only 1112 (D)= 1 = TEI mismatch 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##2003-##2

98

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##15-##1

3.16 Remote alarm indication


3.16.1 15 - REMOTE_ALARM
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Remote alarm indication Specific Problems: REMOTE_ALARM Severity: Major Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Remote alarm indication has been detected on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. This means that the other Network Entity (BSC/MSC) has decided to disable the line for some alarm on the PCM stream provided by TRAU. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disabled state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 PCMS trunk A PCMS trunk B =0 = 0x0001 = 0x0002 = 0x0003 = 0x000a = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm

Alarm due to microinterruptions = 0x00cc 0910 (D)= not used 1112 (D)= not used

A30808-X3247-M440-1-7619

99

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##15-##2

100

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##26-##1

3.16.2 26 - REMOTE_ALARM_ON_LINK_A
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Remote alarm indication Specific Problems: REMOTE_ALARM_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Remote alarm indication has been detected on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that the other Network Entity (BSC/MSC) has decided to disable the line for some alarm on the PCM stream provided by TRAU. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm

Alarm due to microinterruptions = 0x00cc 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used

A30808-X3247-M440-1-7619

101

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##26-##2

102

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##27-##1

3.16.3 27 - REMOTE_ALARM_ON_LINK_B
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Remote alarm indication Specific Problems: REMOTE_ALARM_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Remote alarm indication has been detected on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). This means that the other Network Entity (BSC/MSC) has decided to disable the line for some alarm on the PCM stream provided by TRAU. PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch: it enables the other PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm

Alarm due to microinterruptions = 0x00cc 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used

A30808-X3247-M440-1-7619

103

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##27-##2

104

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##16-##1

3.17 Transmission Error


3.17.1 16 - HIGHER_BER_THRESHOLD_EXCEEDED
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Transmission Error Specific Problems: HIGHER_BER_THRESHOLD_EXCEEDED Severity: Major Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The Bit Error Rate has exceeded the higher threshold on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disable state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 PCMS trunk A PCMS trunk B =0 = 0x0001 = 0x0002 = 0x0003 = 0x000a = 0x000b

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm) 0506 (D)= BER Value:10exp(-3) = 0xff 10exp(-4) 10exp(-5) 10exp(-6) 10exp(-7) 10exp(-8) 10exp(-9) 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used = 0xdf = 0x9f = 0x1f = 0x1e = 0x1c = 0x18

A30808-X3247-M440-1-7619

105

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##16-##2

106

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##17-##1

3.17.2 17 - LOWER_BER_THRESHOLD_EXCEEDED
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: QUALITY OF SERVICE FAILURE EVENT Probable Cause: Transmission Error Specific Problems: LOWER_BER_THRESHOLD_EXCEEDED Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: It is valid for MSCI V2 only. The Bit Error Rate has gone beyond the threshold fixed by the operator on a PCMT line.PCM Device Controller informs Status Manager Task about trunk faulted. PCMT object is put in enabled/degraded state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 =0 = 0x0001 = 0x0002 = 0x0003

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm) 0506 (D)= BER Value (MSCI V2 only): 10exp(-3) 10exp(-4) 10exp(-5) 10exp(-6) 10exp(-7) 10exp(-8) 10exp(-9) 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used = 0xff = 0xdf = 0x9f = 0x1f = 0x1e = 0x1c = 0x18

A30808-X3247-M440-1-7619

107

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

2728 (D)= not used 2930 (D)= not used


##17-##2

108

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##28-##1

3.17.3 28 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Higher BER Threshold Exceeded alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch:it enables the others PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm) 0506 (D)= BER Value: 10exp(-3) 10exp(-4) 10exp(-5) 10exp(-6) 10exp(-7) 10exp(-8) 10exp(-9) 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used = 0xff = 0xdf = 0x9f = 0x1f = 0x1e = 0x1c = 0x18

A30808-X3247-M440-1-7619

109

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##28-##2

110

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##29-##1

3.17.4 29 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Higher BER Threshold Exceeded alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted was the active one, PCM Device Controller triggers the trunk switch:it enables the others PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm) 0506 (D)= BER Value: 10exp(-3) 10exp(-4) 10exp(-5) 10exp(-6) 10exp(-7) 10exp(-8) 10exp(-9) 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used = 0xff = 0xdf = 0x9f = 0x1f = 0x1e = 0x1c = 0x18

A30808-X3247-M440-1-7619

111

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##29-##2

112

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##30-##1

3.17.5 30 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: It is valid for BSCI V4 only. A Lower BER Threshold Exceeded alarm has occurred on a PCMS trunk. PCM Device Controller informs Status Manager Task about trunk faulted. PCMS object is put in enabled/degraded state.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm) 0506 (D)= BER Value: (BSCI V4 only) 10exp(-3) 10exp(-4) 10exp(-5) 10exp(-6) 10exp(-7) 10exp(-8) 10exp(-9) 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used = 0xff = 0xdf = 0x9f = 0x1f = 0x1e = 0x1c = 0x18

A30808-X3247-M440-1-7619

113

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##30-##2

114

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##31-##1

3.17.6 31 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Transmission Error Specific Problems: LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: It is valid for BSCI V4 only. A Lower BER Threshold Exceeded alarm has occurred on a PCMS trunk. PCM Device Controller informs Status Manager Task about trunk faulted. PCMS object is put in enabled/degraded state.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0003 (Error Rate Alarm) 0506 (D)= BER Value: (BSCI V2 only) 10exp(-3) 10exp(-4) 10exp(-5) 10exp(-6) 10exp(-7) 10exp(-8) 10exp(-9) 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used = 0xff = 0xdf = 0x9f = 0x1f = 0x1e = 0x1c = 0x18

A30808-X3247-M440-1-7619

115

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##31-##2

116

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1010-##1

4 ITU Probable Causes


4.1 Configuration Or Customization Error
4.1.1 1010 - HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER Severity: Warning Proposed Repair Actions: Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 38 Status Manager Notify Handler Error description: The card version is not compatible with the TRAU configuration (TypeOfTraue is WITHOUT_TPWR).
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1010-##2

A30808-X3247-M440-1-7619

117

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1032-##1

4.1.2

1032 - TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION Severity: Minor Proposed Repair Actions: Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: This error is generated when the TRAC HW is not able to manage a circuit pool required for a certain TSLA. Moreover, this failure is emitted when CTM service is enabled and the TRAC card have hardware version different from V7. TRAC card is put in disabled/failed state
0102 (D)= .code line number 0304 (D)= staus. 0506 (D)= waiting. 0708 (D)= flag. 0910 (D)= diag 1112 (D)= AAAA - fixed 1314 (S)= Trac instance 1516 (S)= Trac Hardware Version 1718 (D)= SWLoadHeader_file_version. 1920 (S)= Trau Type: 0xB: NO_AMR. 0xC: AMR 0xD: MIX AMR & NO_AMR 2122 (S)= VQE Status: 0=Disabled; 1=Enabled 2324 (S)= CTM Status: 0=Disabled; 1=Enabled 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1032-##2

118

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1036-##1

4.1.3

1036 - BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE Severity: Major Proposed Repair Actions: Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base, 26 BSMS Device Handler Error description: The BSCI card doesn't allow the PCMTYPE attribute value. If the BSCI is active the BSMS restart using the default setting for the PCMTYPE attribute. If the BSCI is standby the BSMS goes into disabled failed state.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1036-##2

A30808-X3247-M440-1-7619

119

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1038-##1

4.1.4

1038 - MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: EQUIPMENT FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE Severity: Major Proposed Repair Actions: Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base, 26 BSMS Device Handler Error description: The MSCI card doesn't allow the PCMTYPE attribute value. If the MSCI is active the BSMS restart using the default setting for the PCMTYPE attribute. If the MSCI is standby the BSMS goes into disabled failed state.
0102 (D)= error code: COMDH_ER_PCM24MSCIHW_INCONS 123 0304 (D)= signal type 0506 (D)= signal subtype 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1038-##2

120

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1103-##1

4.1.5

1103 - TPWR_OFFREQUEST_PENDING

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: TPWR_OFFREQUEST_PENDING Severity: Warning Proposed Repair Actions: Lock the related equipment Lock the related equipment. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 38 Status Manager Notify Handler Error description: A power off request is pending. The TPWR will be switched off when it will be locked.
0102 (D)= Object Class. 0304 (D)= Object mnemonic. 0506 (D)= Object instance. 0708 (D)= 0xffff 0910 (D)= Case discriminator. 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1103-##2

A30808-X3247-M440-1-7619

121

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1116-##1

4.1.6

1116 - TRAC_HW_NOT_COMPATIBLE_WITH_VQE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: TRAC_HW_NOT_COMPATIBLE_WITH_VQE Severity: Warning Proposed Repair Actions: Check the configuration/HW compatibility Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 27 TRAC Device Handler Error description: This warning is emitted to inform operator that VQE service isn't avaible for those TRACs with HW version different from V7. Note: The FER TRAC_HW_NOT_COMPATIBLE_WITH_VQE is emitted on local TRAU LMT only. The severity is WARNING, and then there isn't any alarm enqueuing. On BSC side, the information about compability between VQE service and TRAC hw version is available using GETINFO TRAU command.
0102 (D)= line code 0304 (D)= staus.. 0506 (D)= waiting. 0708 (D)= flag. 0910 (D)= diag 1112 (S)= TRAC instance 1314 (S)= TRAC Hardware Version. 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1116-##2

122

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##2002-##1

4.1.7

2002 - UNEXPECTED_TEI

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Configuration Or Customization Error Specific Problems: UNEXPECTED_TEI Severity: Critical Proposed Repair Actions: Check the LAPD parameters on both side Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 32 BSC_LINKMNGR_TSK Error description: TRAU has been configured with wrong TEI: PPLD has accepted the LAPD establishment but, from TDPC viewpoint, a LAPD with TEI X has been established on PCMS Y (X != Y). This LAPD can't be used for O&M purposes, BSC sends periodically on it an "unexpected TEI id" message. The LAPD goes to disabled state.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##2002-##2

A30808-X3247-M440-1-7619

123

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1098-##1

4.2 Congestion
4.2.1 1098 - T_INTERFACE_MESSAGE_LOST
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Congestion Specific Problems: T_INTERFACE_MESSAGE_LOST Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 22 LMT_IO_COLL_TSK Error description: LMT layer 2 software on TRAU isn't able to send further messages toward LMT (output buffer full or "RNR" frame received from LMT). Output section of LMT layer 2 tx software is re-started (buffer is flushed, transmission task is deleted by LMT layer 3 collector task and re-created by abort handler). A certain number of messages toward LMT are lost.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1098-##2

124

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1083-##1

4.3 Corrupt Data


4.3.1 1083 - FLASH_EPROM_MUST_BE_FORMATTED
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Corrupt Data Specific Problems: FLASH_EPROM_MUST_BE_FORMATTED Severity: Major Proposed Repair Actions: Format the BSCI Flash EPROM Format the Flash EPROM of the concerned BSCI card. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 40 CROSSCOPY_TSK Error description: The Flash Eprom is corrupted. The BSMS is put in disabled failed state. System action: Originator = 23 Operation refused Originator = 28 Downloading aborted. If the error occurs during the System initialization, the Flash Eprom is formatted. Originator = 29 Peripheral loading aborted Originator = 40 Crosscopying aborted
0102 (D)= kind of File system used: FAFS = 1 SLFS = 2 0304 (D)= File system function called: OPEN READ WRITE CLOSE ERASE SWCOMPL SWSTATUS FORMAT DIR DBREN = 9 = 10 = 1 = 2 = 3 = 4 = 5 = 6 = 7 = 8

A30808-X3247-M440-1-7619

125

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

0506 (D)= File System error: FLASH MUST BE FORMATTED = 14 0708 (D)= file name first letter (ASCII code) 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1083-##2

126

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1108-##1

4.3.2

1108 - FORMATTING_FLASH_EPROM

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Corrupt Data Specific Problems: FORMATTING_FLASH_EPROM Severity: Major Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: A previously Locked BSMS is formatting its Flash Eprom. The BSMS copy remains in disabled state.
0102 (D)= signal type 0304 (D)= signal subtype 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1108-##2

A30808-X3247-M440-1-7619

127

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1109-##1

4.3.3

1109 - INVALID_FILE_FORMAT

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Corrupt Data Specific Problems: INVALID_FILE_FORMAT Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 29 PERIPH_LOAD_TSK Error description: The loading of a MSCI/TRAC card has been aborted because of a wrong record format. The loading abort of MSCI active card causes the switch of the BSMS configuration or the reset of the BSMS active, if the standby is not available. The loading abort of MSCI standby card cuses the reset of the BSMS standby. The loading abort of a TRAC card reinitializes the procedure; if the maximum attempts number is reached, the card is disabled.
0102 (D)= code statement number(the module is identified) 0304 (D)= error type or parameter value 0506 (D)= link (card) identifier: 00-05 TRAC 0-5 06 MSCI 0708 (D)= processor identifier(meaningful for TRAC cards): 00 Trac controller 01 Dsp 0910 (D)= last transmitted packet 1112 (D)= FSM state value 1314 (D)= Source system of received message 1516 (D)= Signal type of received message 1718 (D)= Signal subtype of received message 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 48 RI Task Error description:

128

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

The nob-RIU file has an invalid size. The sum of the ob-RIU part and of the nob-RIU part cannot exceed 4K. The nob-RIU part is trunkated.
0102 (D)= code statement number(the module is identified) 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1109-##2

A30808-X3247-M440-1-7619

129

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##5001-##1

4.4 Enclosure Door Open


4.4.1 5001 - OPEN_DOOR_ALARM
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: ENVIRONMENTAL FAILURE EVENT Probable Cause: Enclosure Door Open Specific Problems: OPEN_DOOR_ALARM Severity: Critical Proposed Repair Actions: See the foreseen operating company repair action Environmental alarm. The repair action is defined by the operating company. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 47 DC ENVA TSK Error description: The alarm persistency sensed by the Scan Work Function which polls the ENVA sense point on the BSCI card has reached the threshold fixed by the operator.
0102 (D)= for internal use only 0304 (D)= for internal use only 0506 (D)= ENVA instance = 0 0708 (D)= Threshold 0910 (D)= Counter 1112 (D)= Name of the ENVA 1314 (D)= Scan Work Function FLAG: Disabled = 0 Enabled = 1 1516 (D)= Interface logic Negative Logic = 0 Positive Logic = 1 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##5001-##2

130

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##13-##1

4.5 Loss Of Frame


4.5.1 13 - LOSS_OF_FRAME_ALIGNMENT
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_FRAME_ALIGNMENT Severity: Major Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The Frame Alignment has been lost on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disabled state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 PCMS trunk A PCMS trunk B =0 = 0x0001 = 0x0002 = 0x0003 = 0x000a = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used

A30808-X3247-M440-1-7619

131

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##13-##2

132

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##14-##1

4.5.2

14 - LOSS_OF_CRC_ALIGNMENT

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_CRC_ALIGNMENT Severity: Major Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Loss of CRC Alignment alarm has occurred on a PCMS trunk without redundancy (the other trunk is NOT EQUIPPED or FAULTED) or on a PCMT line. PCM Device Controller informs Status Manager Task about trunk faulted. The PCM line is put in disabled state.
0102 (S)= PCM line alarmed: PCMT line 0 PCMT line 1 PCMT line 2 PCMT line 3 PCMS trunk A PCMS trunk B =0 = 0x0001 = 0x0002 = 0x0003 = 0x000a = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used

A30808-X3247-M440-1-7619

133

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##14-##2

134

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##22-##1

4.5.3

22 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The frame Alignment has been lost on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##22-##2

A30808-X3247-M440-1-7619

135

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##23-##1

4.5.4

23 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: The frame Alignment has been lost on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##23-##2

136

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##24-##1

4.5.5

24 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_A

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_CRC_ALIGNMENT_ON_LINK_A Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Loss of CRC Alignment alarm has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk A = 0x000a

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following values: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##24-##2

A30808-X3247-M440-1-7619

137

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##25-##1

4.5.6

25 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_B

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Loss Of Frame Specific Problems: LOSS_OF_CRC_ALIGNMENT_ON_LINK_B Severity: Minor Proposed Repair Actions: Check cables, connections, line quality Check the related cables, connections and line quality. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 39 PCM Device Controller Task Error description: A Loss of CRC Alignment has occurred on a PCMS trunk with redundancy (the other trunk is ENABLED or DEGRADED). PCM Device Controller informs Status Manager Task about trunk faulted. If the trunk faulted is the active one, PCM Device Controller triggers the trunk switch: it enables the oter PCMS trunk towards TRAC.
0102 (S)= PCM line alarmed: PCMS trunk B = 0x000b

0304 (D)= Alarm Type Identifier = 0x0002 (Line Alarm) 0506 (D)= Alarm value: it can be the OR of the following val: AIS LCA RAI DTOM_EER LFA LOS = 0x01 = 0x02 = 0x04 = 0x08 = 0x10 = 0x20 = 0x00aa

0708 (D)= Persistent Alarm 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##25-##2

138

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1040-##1

4.6 Out Of Memory


4.6.1 1040 - MEMORY_NOT_AVAILABLE
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: MEMORY_NOT_AVAILABLE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 16 Power Supply Device Controller, 19 IPC Dispatcher, 20 IPC Link Maneger, 21 LMT_IO_DLM_TSK, 22 LMT_IO_COLL_TSK, 27 TRAC Device Handler, 28 DOWNLOAD_TSK, 32 BSC_LINKMNGR_TSK, 40 CROSSCOPY_TSK, 114 TRAC fault detection Error description: No memory was available as a result of the buffer allocation request Case of originator: 21, 22 and 32
0102 (D)= RTE message pool number [7..10] 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1040-##2

A30808-X3247-M440-1-7619

139

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1041-##1

4.6.2

1041 - MAILBOX_CANNOT_BE_CREATED

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: MAILBOX_CANNOT_BE_CREATED Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 18 IPC_COLLECTOR_TSK, 23 Data Base, 24 SM_COMM_TSK Error description: The Operating System limit has been reached. If the Originator is Database (23) a system reset will be executed. This means that if the BSMS is in duplex configuration a copy switch occurs, otherwise a Bring Up is performed.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1041-##2

140

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1093-##1

4.6.3

1093 - EMPTY_RTE_POOL_RESTART

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: EMPTY_RTE_POOL_RESTART Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: One or more RTE+ operating system pools has been found empty. The Number of overflow events for that pool has exceeded the corresponding value in THRESHOLD_TAB.
0102 (D)= RTE+ pool number 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1093-##2

A30808-X3247-M440-1-7619

141

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1094-##1

4.6.4

1094 - EMPTY_MESSAGE_POOL

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: EMPTY_MESSAGE_POOL Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base Error description: A message cannot be allocated. When not even the error notification message can be allocated, a system reset is performed.
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1094-##2

142

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1113-##1

4.6.5

1113 - MEMORY_OVERFLOW

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Out Of Memory Specific Problems: MEMORY_OVERFLOW Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: A memory management error has been detected by the RTE+ operating system.
0102 (D)= 000b: a memory overflow has been detected 000c: a bad memory address has been detected 000d: a message overflow has been detected 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1113-##2

A30808-X3247-M440-1-7619

143

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1016-##1

4.7 Software Error


4.7.1 1016 - AR_PROCEDURAL_ERROR
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: AR_PROCEDURAL_ERROR Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 25 Alarm Reporting Error description: In the Alarm Reporting area an error occoured due to internal data mismatch or system call with the wrong return value. Tipically this error arises after receiving the Get Alarm Event Condition message. The running procedure will be aborted.
0102 (D)= Source code line executed after calling error collector 0304 (D)= System error or internal error 1 = System error 2 = Memory not available 3 = Internal error 0506 (D)= When filled the last source lines executed are shown 0708 (D)= When filled the last source lines executed are shown 0910 (D)= When filled the last source lines executed are shown 1112 (D)= When filled the last source lines executed are shown 1314 (D)= When filled the last source lines executed are shown 1516 (D)= When filled the last source lines executed are shown 1718 (D)= When filled the last source lines executed are shown 1920 (D)= When filled the last source lines executed are shown 2122 (D)= When filled the last source lines executed are shown 2324 (D)= When filled the last source lines executed are shown 2526 (D)= When filled the last source lines executed are shown 2728 (D)= When filled the last source lines executed are shown 2930 (D)= When filled the last source lines executed are shown
##1016-##2

144

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1017-##1

4.7.2

1017 - RTE_INTERRUPT_LOOP

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: RTE_INTERRUPT_LOOP Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: An interrupt handler is called continously as a result of a persistent interrupt, without releasing CPU control to the RTE+ operating system scheduler. After 4 interrupt loops, the RTE+ operating system performs a system initialization (with copy switch).
0102 (D)= not used 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1017-##2

A30808-X3247-M440-1-7619

145

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1018-##1

4.7.3

1018 - STANDBY_ALIGNMENT_FAILED

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: STANDBY_ALIGNMENT_FAILED Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 35 Alignment Service Task Error description: The alignment of the stand-by BSCI has failed
0102 (D)= 'C' statement number 0304 (D)= FSM state value 0506 (D)= source system of received message 0708 (D)= source mailbox of received message 0910 (D)= signal type of received message 1112 (D)= signal subtype of received message 1314 (D)= data length of received message 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1018-##2

146

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1034-##1

4.7.4

1034 - SCHEDULER_BLOCKED

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: SCHEDULER_BLOCKED Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: The internal scheduler audit has found that a task is consuming real time in such a way to prevent other task from running. The additional info specify which scheduling queue is blocked.
0102 (D)= 37, prime time queue 0304 (D)= 38, spare time queue 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1034-##2

A30808-X3247-M440-1-7619

147

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1035-##1

4.7.5

1035 - INITIALIZATION_UPDATED

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: INITIALIZATION_UPDATED Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: The internal scheduler audit has found too many initialization of the same time and has changed the initialization level according to the additional info values:
0102 (D)= 34, from full init to spare task init 0304 (D)= 35, from prime task to full init 0506 (D)= 36, from spare task to prime task init 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1035-##2

148

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1043-##1

4.7.6

1043 - INITIALIZATION_FAILURE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: INITIALIZATION_FAILURE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 28 DOWNLOAD_TSK Error description: Download task initialization in dedicated time failure.
0102 (D)= kind of error: FILE SYSTEM ERROR FLASH MUST BE FORMATTED MEMORY ALLOCATION ERROR UNEXPECTED FILE ERROR MESSAGE SENDING ERROR 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used =1 =2 =3 =4 =5

Originator: 121 HSCX Init Handler Error description: It was not possible to initialize the BSCI card IPC services at initialization time, which may cause more severe errors.
0102 (D)= not used

A30808-X3247-M440-1-7619

149

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1043-##2

150

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1046-##1

4.7.7

1046 - FILE_SYSTEM_ERROR

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: FILE_SYSTEM_ERROR Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base, 28 DOWNLOAD_TSK, 29 PERIPH_LOAD_TSK, 36 FAFS_COMPACTION_TASK, 40 CROSSCOPY_TSK, 48 RI Task Error description: An attempt to access to the Flash Eprom was failed. System action: Originator = 23 Operation refused Originator = 28 Downloading aborted Originator = 29 Peripheral loading aborted Originator = 23 Crosscopy aborted Originator = 36 Compaction procedure problems
0102 (D)= kind of File system used: FAFS SLFS =1 =2

if originator is 36, this word means :module line where the error occurred. 0304 (D)= File system function called: OPEN READ WRITE CLOSE ERASE SWCOMPL SWSTATUS FORMAT DIR DBREN = 1 = 2 = 3 = 4 = 5 = 6 = 7 = 8 = 9 = 10

A30808-X3247-M440-1-7619

151

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

if originator is = 36, this word means: FLASH_NOT_VALID NOT_ENOUGH_ROOM NOT_ENOUGH_DESCRIPTOR CRC_NOT_VALID FILE_DOES_NOT_EXIST FILE_SYSTEM_BUSY FILE_ALREADY_CLOSED 1 2 3 4 5 6 7

FILE_NOT_OPENED_FOR_WRITE_OR_APPEND 8 FILE_NOT_OPENED_FOR_READ FLASH_ALREADY_FULL WRONG_OPEN_MODE WRONG_FILE_VERSION WRONG_PARAMETER FLASH_MUST_BE_FORMATTED NOT_OWNER SLFS_MALLOC_FAILED FAFS_MALLOC_FAILED FAFS_WRONG_FILE_NAME FAFS_COMPACT_IN_PRG FAFS_FILE_IN_USE FAFS_FILE_CORRUPTED FAFS_INTERNAL_ERR FAFS_FILE_TOO_LARGE 0506 (D)= File system error number: FLASH NOT VALID NOT ENOUGH ROOM =1 =2 =3 9 10 11 12 13 14 15 16 20 21 22 23 24 25 26

NOT ENOUGH DESCRIPTOR CRC NOT VALID =4 =5

FILE DOES NOT EXIST FILE SYSTEM BUSY FILE CLOSED =7 =8

=6

FILE NOT OPENED

FILE NOT OPENED FOR READ = 9 FLASH FULL = 10 = 11 = 12 = 13

WRONG OPEN MODE WRONG FILE VERSION WRONG PARAMETER

FLASH MUST BE FORMATTED = 14 NOT OWNER = 15 = 20 = 21

FAFS MALLOC FAILED

FAFS WRONG FILE NAME

FAFS COMPACT IN PROGRESS = 22 FAFS FILE_IN USE = 23 = 24

FAFS FILE CORRUPTED

152

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

FAFS INTERNAL ERROR FILE TOO LARGE GENERIC WRITE ERROR

= 25 = 26 = 0x0100 = 0x0200 = 0x0300

FLASH EPROM FSM TIMEOUT UNSUCCESSFUL ERASING FLASH EPROM BLOCK

WRONG OPERATION SEQUENCE IN FLASH ACCESSING = 0x0400 FLASH EPROM INTERNAL WRITE ERROR MAX ATTEMPT OF WRITING RETRY WRITE ERROR DATA MISMATCH WRITE ERROR CELL ALREADY WRITTEN 0708 (D)= file name first letter (ASCII code) 0910 (D)= COMPACT IN PROGRESS COMPACT NOT IN PROGRESS 1112 (D)= WRITE LOCKED NOT WRITE LOCKED 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1046-##2

= 0x1000 = 0x2000 = 0x3000 = 0x4000

= 1 = 0 = 1 = 0

(for internal use only) (for internal use only) (for internal use only) (for internal use only)

A30808-X3247-M440-1-7619

153

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1049-##1

4.7.8

1049 - INTERNAL_LINK_FAILURE

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: COMMUNICATION FAILURE EVENT Probable Cause: Software Error Specific Problems: INTERNAL_LINK_FAILURE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 18 IPC_COLLECTOR_TSK Error description: An error occurred while trying to dispatch a message from the BSCI card toward another card (BSCI, TRAC or MSCI) using the internal link IPC. This error means that one message has been discarded as a result of: - link not established - no buffer available for sending after a requeuing retry - internal errors The exact cause can be determined according to the additional info values
0102 (D)= Source line of the file osiccl.c where the error occurred 0304 (D)= Internal link number (0..5 TRAC, 6 MSCI, 7 BSCI other copy) 0506 (D)= Internal link manager error code 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1049-##2

154

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1053-##1

4.7.9

1053 - BSMS_PROCEDURAL_ERROR

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: BSMS_PROCEDURAL_ERROR Severity: Major Proposed Repair Actions: Test the addressed card(s) Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 26 BSMS Device Handler Error description: A BSMS reconfiguration procedure has failed. The BSMS is put disabled failed.
0102 (D)= error code 0304 (D)= signal type 0506 (D)= signal subtype 0708 (D)= shutdowned tasks - high part (meaningless if = FFFF) 0910 (D)= shutdowned tasks - low part (meaningless if = FFFF) 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1053-##2

A30808-X3247-M440-1-7619

155

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1068-##1

4.7.10 1068 - TIMER_CANNOT_BE_SET


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: TIMER_CANNOT_BE_SET Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 24 SM_COMM_TSK, 32 BSC_LINKMNGR_TSK Error description: Error calling the RTE System Call 'd_timer'. An error in the parameter passed at the System Call has occurred.
0102 (D)= Timer Number. 0304 (D)= Timer Value. 0506 (D)= Timer Unit. 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used

Originator: 23 Data Base Error description: Error calling the RTE System Call 'd_timer'. An error in the parameter passed at the System Call has occurred. A system reset will be executed. This means that: - if the BSMS is in duplex configuration a copy switch occurs, otherwise a Bring Up is performed
0102 (D)= not used 0304 (D)= not used

156

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1068-##2

A30808-X3247-M440-1-7619

157

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1084-##1

4.7.11 1084 - STANDBY_NOT_ALIGNED


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: STANDBY_NOT_ALIGNED Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 23 Data Base, 38 Status Manager Notify Handler Error description: An updating or an alignment procedure is failed: the standby BSMS is not aligned; the standby status remains COLD STANDBY. An alignment procedure is attemptedup to three times. The alignment procedure is successful when the standby status becomes HOT STANDBY.
0102 (D)= line code 0304 (D)= not used 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1084-##2

158

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1099-##1

4.7.12 1099 - RTE_AUDIT_ERROR


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: RTE_AUDIT_ERROR Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: An internal RTE+ operating system audit has reported some problems
0102 (D)= 0018: a message audit error has occurred, the error reports the lost messages or the bad

messages found by the internal audit 0019: a mailbox audit error has occurred, in this case 0304 = the number of bad mailboxes found (HEX) 001A: a task audit error has occurred, in this case 0304 = the number of bad TCBs found (HEX) 001B: a scheduler audit error has occurred 0020: an interrupt looop error has occurred. One interrupt has been served multiple times without releasing CPU control to the scheduler 0304 (D)= the number of bad mailboxes found (HEX) or the number of bad TCBs found (HEX) 0506 (D)= not used 0708 (D)= not used 0910 (D)= not used 1112 (D)= not used 1314 (D)= not used 1516 (D)= not used 1718 (D)= not used 1920 (D)= not used 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1099-##2

A30808-X3247-M440-1-7619

159

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1107-##1

4.7.13 1107 - BSCI_RESET_CAUSE


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: BSCI_RESET_CAUSE Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 111 BSMS Fault Detection Error description: The BSCI has been reset and initialized.
0102 (D)= object class identifier see Asub coding 0304 (D)= mnemonic see Asub coding 0506 (D)= object instance 0708 (D)= error identifier 0910 (D)= reset originator 1112 (D)= reserved to reset originator 1314 (D)= reserved to reset originator 1516 (D)= reserved to reset originator 1718 (D)= reserved to reset originator 1920 (D)= reserved to reset originator 2122 (D)= reserved to reset originator 2324 (D)= reserved to reset originator 2526 (D)= reserved to reset originator 2728 (D)= reserved to reset originator 2930 (D)= reserved to reset originator Notes: if 0102 = FFFF, the error identifier is proprietary to the originator if all additional info are 0000, the cause is the power off if all additional info are F0F0, the cause is the hw reset

if 0910 = BLOADER ORIGINATOR (7C) 0708 can be: BSCI WDT TIMEOUT FILE SYSTEM ERROR = 4

= 46

if 0708 = FILE_SYSTEM_ERROR 1112 can be: FLASH NOT VALID NOT ENOUGH ROOM = = 1 2 = 3

NOT ENOUGH DESCRIPTOR

160

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

CRC NOT VALID FILE DOES NOT EXIST FILE SYSTEM BUSY FILE CLOSED FILE NOT OPENED =

4 = = 6 5

7 = = 8 9

FILE NOT OPENED FOR READ FLASH FULL = 10 = 11 = 12 = 13

WRONG OPEN MODE WRONG FILE VERSION WRONG PARAMETER

FLASH MUST BE FORMATTED

= 14

if FLASH MUST BE FORMATTED 1314 can be: FLASH NOT VALID FILE_SYSTEM_BUSY FLASH HAS BEEN FORMATTED BSCI NOT FOUND in FLASH NOT OWNER WRITE ERROR VPP BWS VPP and BWS ES VPP and ES ES and BWS VPP, BWS and ES OPERATION TIMEOUT ERASE ERROR COMMAND SEQUENCE ERROR EOF_WITHOUT_END_RECORD BAD_RECORD_CHECKSUM BAD_RECORD_FORMAT
##1107-##2

= = = =

1 6 83 84

15 = 100 (byte write,read back failed) = 101 (VPP missing status reg. error) = 102 (byte write status reg. error) = 103

= 104 (erase status reg. error) = 105 = 106 = 107 = 200 = 300 = 400 = = = 82 80 81

A30808-X3247-M440-1-7619

161

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1110-##1

4.7.14 1110 - PERIPHERAL_LOADING_ERROR


FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Error Specific Problems: PERIPHERAL_LOADING_ERROR Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 29 PERIPH_LOAD_TSK Error description: The loading of a MSCI/TRAC card has been aborted because of an unrecoverable file transfer protocol error. Th loading abort of MSCI active card causes the switch of the BSMS configuration or the reset of the BSMS active, if the standby is not available. The loading abort of MSCI standby card causes the reset of the BSMS standby. The loading abort of a TRAC card reinitializes the procedure; if the maximum attempts number is reached, the card is disabled.
0102 (D)= code statement number 0304 (D)= error type or parameter value 0506 (D)= link (card) identifier: 00-05 TRAC 0-5 06 MSCI

0708 (D)= processor identifier (meaningful for TRAC cards): 00 01 0910 (D)= last transmitted packet 1112 (D)= FSM state value 1314 (D)= source system of received message 1516 (D)= signal type of received message 1718 (D)= signal subtype of received message 1920 (D)= transmitted bytes 2122 (D)= not used 2324 (D)= not used 2526 (D)= not used 2728 (D)= not used 2930 (D)= not used
##1110-##2

Trac controller Dsp

162

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

##1111-##1

4.8 Software Program Abnormally Terminated


4.8.1 1111 - DELETED_CURRENT_TASK
FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Program Abnormally Terminated Specific Problems: DELETED_CURRENT_TASK Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: The RTE+ operating system has deleted the current task or aborted the current scan work function.
0102 (D)= Task logical name 0304 (D)= not used 0506 (D)= If greater than 0, interrupt which caused the task to be deleted together with the processor register values 0708 (D)= segment of the task executing during the interrupt 0910 (D)= offset of the task executing during the interrupt 1112 (D)= CS register value 1314 (D)= IP register value 1516 (D)= SS register value 1718 (D)= SP register value 1920 (D)= BP register value 2122 (D)= DS register value 2324 (D)= ES register value 2526 (D)= SI register value 2728 (D)= AX register value 2930 (D)= BX register value
##1111-##2

A30808-X3247-M440-1-7619

163

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

##1112-##1

4.8.2

1112 - DELETED_CURRENT_INIT_FUNCTION

FAILURE EVENT REPORT: Managed Object Class/ <R.T.D.> Hardware Type: Event Type: PROCESSING FAILURE EVENT Probable Cause: Software Program Abnormally Terminated Specific Problems: DELETED_CURRENT_INIT_FUNCTION Severity: Warning Proposed Repair Actions: No action NoAction (Standard value). Immediate Defense Actions: n/a Lower Threshold: n/a Defense actions: n/a Upper Threshold: n/a Defense actions: n/a Alarm Filtering: n/a Additional Words: 0102 0304 0506 0708 0910 1112 1314 1516 1718 1920 2122 2324 2526 2728 2930 Originator: 123 RTE_ORIGINATOR Error description: The RTE+ operating system has deleted the current task or aborted the current scan work function
0102 (D)= Last initialization index 0304 (D)= Initialization function index 0506 (D)= If greater than 0, interrupt which caused the task to be deleted together with the processor register values 0708 (D)= segment of the task executing during the interrupt 0910 (D)= offset of the task executing during the interrupt 1112 (D)= CS register value 1314 (D)= IP register value 1516 (D)= SS register value 1718 (D)= SP register value 1920 (D)= BP register value 2122 (D)= DS register value 2324 (D)= ES register value 2526 (D)= SI register value 2728 (D)= AX register value 2930 (D)= BX register value
##1112-##2

164

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

5 Index of Specific Problems


11 - LOSS_OF_SIGNAL.................................................................................................................................. 46 12 - AIS_ALARM ............................................................................................................................................. 48 13 - LOSS_OF_FRAME_ALIGNMENT ......................................................................................................... 131 14 - LOSS_OF_CRC_ALIGNMENT.............................................................................................................. 133 15 - REMOTE_ALARM.................................................................................................................................... 99 16 - HIGHER_BER_THRESHOLD_EXCEEDED.......................................................................................... 105 17 - LOWER_BER_THRESHOLD_EXCEEDED .......................................................................................... 107 18 - LOSS_OF_SIGNAL_ON_LINK_A............................................................................................................ 50 19 - LOSS_OF_SIGNAL_ON_LINK_B............................................................................................................ 52 20 - AIS_ALARM_ON_LINK_A ....................................................................................................................... 54 21 - AIS_ALARM_ON_LINK_B ....................................................................................................................... 56 22 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_A ................................................................................... 135 23 - LOSS_OF_FRAME_ALIGNMENT_ON_LINK_B ................................................................................... 136 24 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_A........................................................................................ 137 25 - LOSS_OF_CRC_ALIGNMENT_ON_LINK_B........................................................................................ 138 26 - REMOTE_ALARM_ON_LINK_A............................................................................................................ 101 27 - REMOTE_ALARM_ON_LINK_B............................................................................................................ 103 28 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_A.................................................................... 109 29 - HIGHER_BER_THRESHOLD_EXCEEDED_ON_LINK_B.................................................................... 111 30 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_A .................................................................... 113 31 - LOWER_BER_THRESHOLD_EXCEEDED_ON_LINK_B .................................................................... 115 1003 - TRAC_WDT_TIMEOUT ....................................................................................................................... 92 1004 - BSCI_WDT_TIMEOUT......................................................................................................................... 93 1005 - BSCI_WDT_WARNING ....................................................................................................................... 94 1006 - PLL_FAILURE...................................................................................................................................... 15 1007 - BSCI_HW_FAULT................................................................................................................................ 16 1009 - TRAC_TIMING_LOSS ......................................................................................................................... 20 1010 - HW_NOT_COMPATIBLE_WITH_INTERNAL_POWER ................................................................... 117 1012 - PROTECTED_MEMORY_ILLEGAL_WRITE_ATTEMPT.................................................................... 21 1014 - UNEXPECTED_MESSAGE ................................................................................................................. 65 1015 - INPUT_PARAMETER_OUT_OF_RANGE_WARNING ....................................................................... 63 1016 - AR_PROCEDURAL_ERROR ............................................................................................................ 144 1017 - RTE_INTERRUPT_LOOP ................................................................................................................. 145 1018 - STANDBY_ALIGNMENT_FAILED..................................................................................................... 146 1019 - INVALID_DATABASE_WARNING....................................................................................................... 59 1020 - PCMS_CIRCUIT_ALARM .................................................................................................................... 22 1021 - PCMA_CIRCUIT_ALARM .................................................................................................................... 24 1023 - TRAC_DBA_REFUSED ....................................................................................................................... 60 1024 - SYSTEM_CALL_UNSUCCESSFUL_WARNING ................................................................................ 72 1028 - FUNCTION_CALL_UNSUCCESSFUL ................................................................................................ 74 1029 - VARIABLE_OUT_OF_RANGE ............................................................................................................ 91 1032 - TRAC_HW_NOT_COMPATIBLE_WITH_ACTUAL_CONFIGURATION .......................................... 118 1033 - MESSAGE_OUT_OF_SEQUENCE_WARNING ................................................................................. 70 1034 - SCHEDULER_BLOCKED .................................................................................................................. 147 1035 - INITIALIZATION_UPDATED.............................................................................................................. 148 1036 - BSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE ................................................................... 119 1037 - TIMEOUT_EXPIRED_WARNING........................................................................................................ 81 1038 - MSCI_HW_VERSION_NOT_VALID_FOR_PCM_TYPE................................................................... 120 1040 - MEMORY_NOT_AVAILABLE ............................................................................................................ 139 1041 - MAILBOX_CANNOT_BE_CREATED ................................................................................................ 140 1042 - BSMS_DIAGNOSTIC_FAILURE ......................................................................................................... 26 A30808-X3247-M440-1-7619 165

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

1043 - INITIALIZATION_FAILURE................................................................................................................ 149 1044 - INVALID_MESSAGE_DATA ................................................................................................................ 66 1045 - TRAC_DIAGNOSTIC_FAILURE.......................................................................................................... 27 1046 - FILE_SYSTEM_ERROR .................................................................................................................... 151 1047 - TRAC_DIAGNOSTIC_ONLINE_FAILURE .......................................................................................... 28 1048 - INVALID_RTE_HEADER_FIELD_VALUE ........................................................................................... 67 1049 - INTERNAL_LINK_FAILURE .............................................................................................................. 154 1052 - TPWR_DIAGNOSTIC_FAILURE ......................................................................................................... 30 1053 - BSMS_PROCEDURAL_ERROR ....................................................................................................... 155 1059 - MSCI_HW_FAULT ............................................................................................................................... 31 1060 - MSCI_SW_ERROR.............................................................................................................................. 68 1066 - MESSAGE_NOT_SENT ...................................................................................................................... 77 1067 - INVALID_DB_CALL ............................................................................................................................. 79 1068 - TIMER_CANNOT_BE_SET ............................................................................................................... 156 1074 - TPWR_FAULT ..................................................................................................................................... 32 1075 - TRAC_KEEP_ALIVE_ALARM ............................................................................................................. 85 1077 - TRAC_HW_FAULT .............................................................................................................................. 33 1078 - MSCI_SYNC_8KHZ_FAILED .............................................................................................................. 34 1079 - MSCI_DIGA_FAULTED ....................................................................................................................... 35 1080 - TRAC_UNEXPECTED_MESSAGE ..................................................................................................... 69 1081 - TRAC_FAIL_TO_LOAD ....................................................................................................................... 36 1082 - FLASH_EPROM_NOT_VALID ............................................................................................................ 37 1083 - FLASH_EPROM_MUST_BE_FORMATTED ..................................................................................... 125 1084 - STANDBY_NOT_ALIGNED ............................................................................................................... 158 1086 - TRAC_LINK_FAILURE ........................................................................................................................ 39 1087 - DSP_TSYNC_EXPIRED ...................................................................................................................... 86 1088 - TRAC_CARD_FAILURE ...................................................................................................................... 40 1089 - DSP_FAIL_TO_LOAD.......................................................................................................................... 41 1090 - DSP_KEEP_ALIVE_ALARM................................................................................................................ 87 1091 - DATABASE_INCONSISTENCY_BRINGUP ........................................................................................ 61 1093 - EMPTY_RTE_POOL_RESTART....................................................................................................... 141 1094 - EMPTY_MESSAGE_POOL ............................................................................................................... 142 1096 - SYSTEM_CALL_UNSUCCESSFUL_MINOR...................................................................................... 80 1097 - BAD_PLL_INPUT_SYNCHRONISATION ........................................................................................... 58 1098 - T_INTERFACE_MESSAGE_LOST ................................................................................................... 124 1099 - RTE_AUDIT_ERROR ........................................................................................................................ 159 1100 - BSCI_CARD_FAILURE........................................................................................................................ 42 1102 - PROBABLE_DATABASE_INCONSISTENCY ..................................................................................... 62 1103 - TPWR_OFFREQUEST_PENDING.................................................................................................... 121 1104 - BSCI_KEEP_ALIVE_ALARM............................................................................................................... 43 1105 - MSCI_KEEP_ALIVE_ALARM .............................................................................................................. 44 1106 - INCONSISTENT_STATUS .................................................................................................................. 45 1107 - BSCI_RESET_CAUSE....................................................................................................................... 160 1108 - FORMATTING_FLASH_EPROM....................................................................................................... 127 1109 - INVALID_FILE_FORMAT................................................................................................................... 128 1110 - PERIPHERAL_LOADING_ERROR ................................................................................................... 162 1111 - DELETED_CURRENT_TASK............................................................................................................ 163 1112 - DELETED_CURRENT_INIT_FUNCTION ......................................................................................... 164 1113 - MEMORY_OVERFLOW..................................................................................................................... 143 1114 - INVALID_POINTER_WARNING.......................................................................................................... 64 1115 - UNABLE_TO_RUN_TEST ................................................................................................................... 96 1116 - TRAC_HW_NOT_COMPATIBLE_WITH_VQE.................................................................................. 122 2001 - ASUB_TRANSIENT_FAILURE............................................................................................................ 97 2002 - UNEXPECTED_TEI ........................................................................................................................... 123 2003 - LPDL_LINK_DOWN ............................................................................................................................. 98 5001 - OPEN_DOOR_ALARM ...................................................................................................................... 130 5002 - FAN_ALARM ........................................................................................................................................ 95

166

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

A30808-X3247-M440-1-7619

167

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

168

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

6 ANNEX A
TRAU SPECIFIC PROBLEM

Specific Problems

Probable Cause

Name
Loss Of Signal AIS Alarm Loss Of Frame Alignment Loss Of CRC Alignment Remote Alarm Higher BER Threshold Exceeded Lower BER Threshold Exceeded Loss Of Signal On Link A Loss Of Signal On Link B AIS Alarm On Link A AIS Alarm On Link B Loss Of Frame Alignment On Link A Loss Of Frame Alignment On Link B Loss Of CRC Alignment On Link A Loss Of CRC Alignment On Link B Remote Alarm On Link A Remote Alarm On Link B Higher BER Threshold Exceeded On Link A Higher BER Threshold Exceeded On Link B Lower BER Threshold Exceeded On Link A Lower BER Threshold Exceeded On Link B TRAC WDT Timeout BSCI WDT Timeout BSCI WDT Warning PLL Failure BSCI HW Fault TRAC Timing Loss HW Not Compatible With Internal Power Protected Memory Illegal Write Attempt A30808-X3247-M440-1-7619

Value

Name
LineInterfaceFailure LineInterfaceFailure LossOfFrame LossOfFrame RemoteAlarmIndication TransmissionError TransmissionError LineInterfaceFailure LineInterfaceFailure LineInterfaceFailure LineInterfaceFailure LossOfFrame LossOfFrame LossOfFrame LossOfFrame RemoteAlarmIndication RemoteAlarmIndication TransmissionError TransmissionError TransmissionError TransmissionError WatchDogTimerExpired WatchDogTimerExpired WatchDogTimerExpired EquipmentFailure EquipmentFailure EquipmentFailure ConfigurationOrCustomizationError EquipmentFailure

Item
GSM GSM ISO ISO GSM GSM GSM GSM GSM GSM GSM ISO ISO ISO ISO GSM GSM GSM GSM GSM GSM GSM GSM GSM GSM GSM GSM ISO GSM 16 16 28 28 71 74 74 16 16 16 16 28 28 28 28 71 71 74 74 74 74 48 48 48 09 09 09 07 09 169

0011 0012 0013 0014 0015 0016 0017 0018 0019 0020 0021 0022 0023 0024 0025 0026 0027 0028 0029 0030 0031 1003 1004 1005 1006 1007 1009 1010 1012

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

Unexpected Message Input Parameter Out Of Range Warning AR Procedural Error RTE Interrupt Loop Standby Alignment Failed Invalid Database Warning PCMS Circuit Alarm PCMA Circuit Alarm TRAC DBA Refused System Call Unsuccessful Warning Function Call Unsuccessful Variable Out Of Range TRAC HW Not Compatible With Actual Conf. Message Out Of Sequence Warning Scheduler Blocked Initialization Updated BSCI HW Version Not Valid For PCM Type Timeout Expired Warning MSCI HW Version Not Valid For PCM
Type

1014 1015 1016 1017 1018 1019 1020 1021 1023 1024 1028 1029 1032 1033 1034 1035 1036 1037 1038 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1052 1053 1059 1060 1066 1067 1068 1074

MessageNotExpected InputParameterOutOfRange SoftwareError SoftwareError SoftwareError DatabaseInconsistency EquipmentFailure EquipmentFailure DatabaseInconsistency SystemCallUnsuccessful SystemCallUnsuccessful VariableOutOfRange ConfigurationOrCustomizationError MessageOutOfSequence SoftwareError SoftwareError ConfigurationOrCustomizationError TimeoutExpired ConfigurationOrCustomizationError OutOfMemory OutOfMemory EquipmentFailure SoftwareError MessageNotExpected EquipmentFailure SoftwareError EquipmentFailure MessageNotExpected SoftwareError EquipmentFailure SoftwareError EquipmentFailure MessageNotExpected SystemCallUnsuccessful SystemCallUnsuccessful SoftwareError EquipmentFailure

GSM GSM ISO ISO ISO GSM GSM GSM GSM GSM GSM GSM ISO GSM ISO ISO ISO GSM ISO ISO ISO GSM ISO GSM GSM ISO GSM GSM ISO GSM ISO GSM GSM GSM GSM ISO GSM

42 39 46 46 46 37 09 09 37 45 45 47 07 44 46 46 07 46 07 32 32 09 46 42 09 46 09 42 46 09 46 09 42 45 45 46 09

Memory Not Available Mailbox Cannot Be Created BSMS Diagnostic Failure Initialization Failure Invalid Message Data TRAC Diagnostic Failure File System Error TRAC Diagnostic Online Failure Invalid RTE Header Field Value Internal Link Failure TPWR Diagnostic Failure BSMS Procedural Error MSCI HW Fault MSCI SW Error Message Not Sent Invalid DB Call Timer Cannot Be Set TPWR Fault 170

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

TRAC Keep Alive Alarm TRAC HW Fault MSCI SYNC 8KHz Failed MSCI DIGA Faulted TRAC Unexpected Message TRAC Fail To Load Flash EPROM Not Valid Flash EPROM Must Be Formatted StandBy Not Aligned TRAC Link Failure DSP TSYNC Expired TRAC Card Failure DSP Fail To Load DSP Keep Alive Alarm Database Inconsistency BringUp Empty RTE Pool Restart Empty Message Pool System Call Unsuccessful Minor Bad PLL Input Synchronisation T Interface Message Lost RTE Audit Error BSCI Card Failure Probable Database Inconsistency TPWR Offrequest Pending BSCI Keep Alive Alarm MSCI Keep Alive Alarm Inconsistent Status BSCI Reset Cause Formatting Flash EPROM Invalid File Format Peripheral Loading Error Deleted Current Task Deleted Current Init Function Memory Overflow Invalid Pointer Warning Unable To Run Test Asub Transient Failure A30808-X3247-M440-1-7619

1075 1077 1078 1079 1080 1081 1082 1083 1084 1086 1087 1088 1089 1090 1091 1093 1094 1096 1097 1098 1099 1100 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 2001

TimeoutExpired EquipmentFailure EquipmentFailure EquipmentFailure MessageNotExpected EquipmentFailure EquipmentFailure CorruptData SoftwareError EquipmentFailure TimeoutExpired EquipmentFailure EquipmentFailure TimeoutExpired DatabaseInconsistency OutOfMemory OutOfMemory SystemCallUnsuccessful LossOfSynchronization Congestion SoftwareError EquipmentFailure DatabaseInconsistency ConfigurationOrCustomizationError EquipmentFailure EquipmentFailure EquipmentFailure SoftwareError CorruptData CorruptData SoftwareError SoftwareProgramAbnormallyTerminat
ed

GSM GSM GSM GSM GSM GSM GSM ISO ISO GSM GSM GSM GSM GSM GSM ISO ISO GSM GSM ISO ISO GSM GSM ISO GSM GSM GSM ISO ISO ISO ISO ISO ISO ISO GSM GSM GSM

46 09 09 09 42 09 09 09 46 09 46 09 09 46 37 32 32 45 18 08 46 09 37 07 09 09 09 46 09 09 46 47 47 32 41 64 69 171

SoftwareProgramAbnormallyTerminat
ed

OutOfMemory InvalidPointer SystemResourcesOverload LAPDLinkProtocolFailure

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

Unexpected TEI LPDL Link Down Open Door Alarm Fan Alarm

2002 2003 5001 5002

ConfigurationOrCustomizationError LAPDLinkProtocolFailure EnclosureDoorOpen Fan Failure

ISO GSM ISO GSM

07 69 14 53

172

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

7 ANNEX B
TRAU FER PROPOSED REPAIR ACTION

1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23

24 25 26 27 28 29

NoAction (Standard value). RepairActionRequired (Standard value - not used). Replace the addressed card. Test the addressed card(s) and perform the proper action according to the Test Result. Possibly, check also its (their) insertion in the frame. Alarm with warning severity. Refer to the manual for the proposed action. Environmental alarm. The repair action is defined by the operating company. Wait for the end of the Automatic Diagnostic and then perform the proper action according to the Test Result. Check on both sides the parameters of the line connecting the BSC and the faced Network Entity. Then, if it is all right, replace the line interface cards with the correct FW/HW edition. Check on both sides the parameters of the line connecting the BSC and the faced Network Entity. Then, check the line interface card state including the FW/HW editions. If it is all right, test the line interface cards. Finally, check the PCM cables and the HW of the faced Network Element. Check the PCM cable connected to the LICD and, possibly, tune the related BER. Check the signal emitted by the faced Network Element. Then, check the devices on the path between the BSC and the Network Element (CrossConnect, ..). Correct the configuration attribute value(s) for the addressed card(s) or replace the Hardware with one compatible with the configuration. Insert the addressed card in the frame. Then, test it. If the addressed card is the StandBy one, test it. Check the related cables, connections and line quality. Lock the related equipment. Provide information on the state of the BSC card versions (LICD, PLLH, SN) and speech quality to the customer service. Wait for the PLLH warm up (about 15 minutes). Check on both sides the LAPD parameters (TEI, LAPD timeslot) and correct them, if necessary. Format the Flash EPROM of the concerned BSCI card. If there are no more SYNC (SYNE) Managed Objects available to be automatically chosen as a new synchronization source, create a new one. Check the insertion of the LICD in the frame, then test it. If the Test Report is good, replace the UBEX. Replace the LICD and, if after re-entering in service, the problem is already present, call the customer assistance (problem of PLLH, active SN, Rack or Flat cable connecting base and extended modules). If the BSC is synchronized to the MSC, it is a problem of bad external source. If the BSC is free running, it is a problem of bad PLLH signal. Then, tune the PLLH. Test the related MPCC and perform the proper action according to the Test Result. Check the TRAU Network Entity. Check the BTS HW. Check the barring information and the BTS HW. Check the TRX HW.

A30808-X3247-M440-1-7619

173

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

List of strings to be displayed on the OMC/LMT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

No Action Repair action required Replace the addressed card Test the addressed card(s) See the proposed action in the manual. See the foreseen operating company repair action See the automatic diagnostic test result Check line configuration on both side Check line configuration/HW on both side Check the LICD PCM cable, tune the BER Check the received signal Check the configuration/HW compatibility Insert and test the addressed card Test the card if it is a standby one Check cables, connections, line quality Lock the related equipment Collect info for Assistance (see manual) Wait for the PLLH warm up (15 minutes) Check the LAPD parameters on both side Format the BSCI Flash EPROM Create a new SYNC (SYNE). Test the LICD. If ok, replace the UBEX NWK,LICD,Flat Cable problem (see manual) Change sync source or tune the PLLH Test the related MPCC Check the TRAU Check the BTS HW. Check barring information and BTS HW Check the TRX HW.

174

A30808-X3247-M440-1-7619

Transcoding and Rate Adaption Unit

Outputs OML:TRAU

8 ANNEX C
TRAU ORIGINATOR

DEFINE
Power Supply Device Controller IPC_LAYER2_TSK IPC_COLLECTOR_TSK IPC Dispatcher IPC Link Maneger LMT_IO_DLM_TSK LMT_IO_COLL_TSK Data Base SM_COMM_TSK Alarm Reporting BSMS Device Handler TRAC Device Handler DOWNLOAD_TSK PERIPH_LOAD_TSK BIFRAMETX_TSK BUFRAMETX_TSK BSC_LINKMNGR_TSK LMT_LINKCTRL_TSK RAM CRC Alignment Service Task FAFS_COMPACTION_TASK SPARE_3_TSK Status Manager Notify Handler PCM Device Controller Task CROSSCOPY_TSK Sync Device Handler BDGDMPEPR_TSK BDGDMPIPR_TSK STBY_DIAG_TSK BSMS_STBY_DIAG_AGENT_TSK EVENT_LOG_TSK DC ENVA TSK RI Task Error Collector NMI Interrupt Handler Spontaneous Alarm

VALUE 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 100 101 102 103 104 105 106 107 108 109
175

ALARM_TILT_ORIGINATOR ALL1_PLL_ORIGINATOR MIR_PLL_ORIGINATOR OTH_CARD_WDT_ORIGINATOR


ALL2_PLL Interrupt Handler

PROTECT_MEM_ORIGINATOR ALM_SPON_ORIGINATOR
A30808-X3247-M440-1-7619

Outputs OML:TRAU

Transcoding and Rate Adaption Unit

SM_COMM_ORIGINAT
BSMS Fault Detection

INT_TILT_ORIGINATOR TEST_BSMS_ORIGINATOR
TRAC fault detection

FAULT_DETECTION_TPWR
WDT Fault Detection

FOMDH_FLASH_CHECK_TSK FOMDH_RAM_CHECK_TSK TPWR_TEST_TSK


Test BSMS HSCX Init Handler BSCI Audit

RTE_ORIGINATOR BLOADER_ORIGINATOR NACK_ACK_ANSWER FDGDM_DIAG_ACTIVATION0 FDGDM_DIAG_ACTIVATION1 SEND_TEST_IN_PROGRESS SEND_PHASE_RESULT TDGDM_PI_PROCESS TDGDMPI_STBY FDGDM_IRAS
Activate Test

FDGDM_SYNC_DEVICE0 FDGDM_SYNC_DEVICE1 STOP_TEST_RUNNING SEND_DSC_TO_SM UPDATE_BSCI_STBY SEND_OUTPUT_RESULT SEND_DUMMY_RESULT FDGDM_OUTPUT FDGHD_BSMS FDGHD_TRAC FDGHD_TPWR MSCI_DIAG_CONTROLLER TDGHD_BSMS_STBY BSCI FW

110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151