You are on page 1of 24

hH

Testing and Measuring


Electromagnetic Compatibility
Performance of the
HFBR-510X/520X Fiber-Optic
Transceivers

Application Note 1075


Contents Abstract electromagnetic compatibility
1.0 Introduction ........................... 1 This application note explains (EMC) while still maintaining
the main components of low cost. The HFBR-510X/520X
2.0 Elements of Electromagnetic
Compatibility......................... 2
electromagnetic compatibility modules are intended for high
2.1a What is Radiated (EMC): radiated emission, data rate applications such as
Emission? ............................... 2 immunity, electrostatic ATM (155 MBaud) or FDDI (125
2.1b How System Design Affects discharge, and conducted noise; MBaud). At these high data
Radiated Emissions................ 3 and describes how the design of rates, achieving acceptable EMC
2.2a What is Susceptibility
(Immunity)? ........................... 5
the communication network performance in communications
2.2b How System Design Affects system affects EMC network products while still
Susceptibility (Immunity)...... 6 performance. It describes how maintaining low product cost
2.3a What is ESD? ......................... 8 Hewlett-Packard’s new HFBR- can be quite a design challenge.
2.3b How System Design Affects 510X/520X 1×9 SC connectored, The excellent EMC performance
ESD......................................... 8
2.4a What is Conducted Noise?.........9
fiber-optic transceivers for data of the HFBR-510X/520X module,
2.4b How System Design Affects rates up to 155 MBaud are plus its low cost, should make
Conducted Noise..................... 9 designed for excellent the EMC design challenge for
electromagnetic compatibility the communication network
3.0 Summary of HFBR- 510X/520X while maintaining low cost. The product easier to overcome.
Component Level
EMC Performance ..................10
application note also describes
the procedures under which the EMC refers to the capability of
4.0 HFBR-510X/520X Component HFBR-510X/520X components electronic equipment or systems
Level EMC Testing.............11 are tested for EMC, and reports to be operated in the intended
4.1a Radiated Emissions Testing the results of these tests. operational electromagetic
Procedure................................11
4.1b Radiated Emissions Testing
environment at their designed
Results....................................13 The application note summa- levels of efficiency. Specifically,
4.2a Susceptibility (Immunity) rizes the HFBR-510X/520X EMC describes how the product
Testing Procedure..................15 components’ EMC performance behaves in terms of radiated
4.2b Susceptibility (Immunity) and stresses their reliability emissions, commonly known as
Testing Results.......................17
4.3a ESD Testing Procedure ........ 18
under various conditions and electromagnetic interference
4.3b ESD Testing Results ............ 19 applications. (EMI), and also how the
4.4a Conducted Noise Testing product’s performance is affected
Procedure................................19 1.0 Introduction by immunity (susceptibility) to
4.4b Conducted Noise Testing Hewlett-Packard has designed radiated energy, electrostatic
Results ................................... 20
its new HFBR-510X/520X, 1×9 discharge (ESD), and conducted
5.0 Conclusions ........................... 21 pinout, SC connector, fiber-optic power supply noise. This
transceivers for excellent application note describes these
2

EMC components, how communi- currents flowing in its conduc- to Data output to Ground,
cation network design can affect tors). Electromagnetic radiation through the Vcc decoupling
the EMC performance, and how occurs when a changing current capacitor, then back to Vcc.
the excellent EMC performance flows in a conductor. At the area Additional examples are the LED
of the HFBR-510X/520X trans- near the conductor (antenna), we current loop in a fiber-optic
ceivers makes it easier to design usually see either the electric or transmitter, and ground wires
fiber-optic communication the magnetic field dominate the (PCB traces) driven by voltage
network products with accept- total radiated field. This area noise sources that act as dipole
able EMC performance. Since near the antenna is called the antennas, and so forth.
the interconnection and the near field. The antenna formed
packaging of the components by taking one long wire and Government agencies around the
used in a communication system breaking it at the center to form world regulate the amount of
affect the EMC performance of two separate wires, is known as radiated electromagnetic energy
the system, HP performed an electric dipole antenna. The emitted by various sources.
various tests on our products to dipole antenna is usually driven Their intent is to allow any
determine how our components by a varying voltage source, with purposely transmitted radiated
affect a final system-level EMC the positive source node con- energy to be received without
performance. This application nected to one wire and the being interfered with by some
note presents the component- negative source node connected other radiation source at around
level EMC testing procedures to the other wire. The dipole the same frequency. Equipment
and results, and explains how antenna near-field radiation is that radiates emissions could
the component-level performance predominately an electric field. interfere with radios in the same
affects the performance of the If a varying current flows in a building or even with other
complete fiber-optic data loop of wire, it creates predomi- electronic equipment that is
communication network. nately magnetic field radiation. sensitive to that radiation.
This antenna is known as a Electromagnetic interference
EMC problems worsen as the (magnetic) loop antenna. At a (EMI) describes the effect of
data rate increases. This applica- point far away from this an- unwanted radiation interfering
tion note details some of the tenna, neither the electric nor with another (intentional or
practices that the equipment the magnetic fields dominate. unintentional receiver) circuit’s
designers can observe to help These areas are known as the operation.
avoid being affected by EMC far-field region. In this region,
when using HP’s new high data the radiation (or equivalently the The government agencies usually
rate HFBR-510X/520X products. electromagnetic wave) becomes set their radiated emissions
what is known as a transverse regulations to distinguish be-
2.0 Elements of electromagnetic wave (TEM). A tween two types of applications.
Electromagnetic TEM wave behaves the same as The first is a factory or office
all the other radio/TV waves that (Class A) where a higher level of
Compatibility (EMC)
travel through the air. The radiation can be tolerated; the
characteristics of the air deter- second is the home (Class B)
2.1a What is Radiated
mine the electric-to-magnetic where there are more TVs and
Emission?
field strengths or, equivalently, radios and therefore less electro-
The first EMC area is radiated
the characteristic impedance of magnetic radiation can be
emissions, sometimes called
the radiation. An actual commu- tolerated. Most manufacturers
electromagnetic interference or
nication system contains various want their systems to meet all of
EMI. A radio or TV broadcast is
antennas formed by the circuit the home environment radiated
an example of intentionally
interconnections and by the emissions specifications used
radiated electromagnetic energy.
other metal bodies in the cir- around the world so that they
A computing device also radiates
cuitry. These antennas are then can be sold in the US, in Europe
electromagnetic emissions,
driven by various energy sources or in Japan, with no restrictions.
although it is not intended to.
within the system circuitry. One In Europe, computer systems
(The radiation is an inherent
example is the loop form by Vcc
by-product of the switching
3

must meet CENLEC EN55022 tains a 155 MHz clock) and radiation that the antennas leak
(Class B). In Japan, it is the FDDI (contains a 125 MHz clock) to the outside world.
VCCI Class 2 specification systems will therefore need to be
which is equal to the CISPR tested to FCC B up to 2 GHz. Circuit components are seldom
22B specification. The Europe and Japan currently do specified in terms of how much
EN55022 specification limits not regulate radiated emissions energy they can radiate. But, as
are identical to the CISPR 22B above 1 GHz, although they are a general rule, don’t use compo-
specification limits. In the expected to follow the FCC nents that are much faster than
USA, all equipment that could example in the near future. you need. The faster the edge
be used in the home must meet speed and the faster the clock
FCC Class B. (If the equipment Most manufacturers want their rate, the more radiated noise the
can meet CISPR 22B, it will equipment to pass FCC B by at circuit generates. Also, circuits
almost certainly meet FCC least 6 dB because the equip- that limit Vcc noise spikes such
Class B.) All equipment not for ment will be much more easily as the differential current
use in the home must meet FCC accepted by the FCC and other switches used in ECL logic can
Class A. In the USA, the agencies. If they don’t pass by 6 help reduce radiated noise.
separation between factory/ dB, then various worst-case Totem pole/CMOS outputs that
office environments and the products with different hookup draw large Vcc current spikes
home environment is such that configurations must usually be when the output switches can
there is a large market for systems tested to convince the FCC that generate lots of noise. Circuits
that meet FCC Class A only. In they will pass FCC B in the which internally limit edge rates
Europe and Japan, the Class A worst case. If they do pass by 6 and Vcc spikes while still giving
market is very limited since almost dB, the FCC will usually certify adequate input/output speeds are
all environments could be consid- that the product passed, as long sometimes available (such as the
ered home environments because as the manufacturer can show “quiet” CMOS family). Also,
offices and homes are often in the that their test setup with a trying to keep transmission lines
same building. Also, most manu- typical product was reasonably short will prevent ringing.
facturers, in general, do not want close to worst case. Thus a 6 dB (Ringing translates into more
to limit their products by making margin at an FCC-approved test high-frequency energy and
them FCC Class A only. site operated by a manufacturer therefore more radiation.) Short
or by an independent test agency Vcc-to-ground decoupling loops
Any product that does not meet implies that any one production will often help reduce Vcc spikes.
the pertinent emissions require- unit of the product that is tested (Sometimes it will make the
ment for a particular country at a FCC certified test site will spikes worse, but the antenna
cannot be legally sold in that pass the FCC limits (by at least smaller, so overall it is usually
country. Any manufacturer 0 dB margin). better). Ferrites can also reduce
who sells equipment that is ringing by adding high-frequency
found to violate the regulations 2.1b How System Design damping resistance.
can, if caught, face large fines Affects Radiated Emissions.
and penalties. Also the manu- System design can affect radi- The antennas are formed by the
facturer may be forced to ated emissions in three main circuit interconnections and by
withdraw the product from the ways. The first way is in the the Vcc-to-ground current loops.
market until the regulating choice of circuit components. Keep these as small as possible.
government agency (FCC in the Some generate more If they are long enough to be
U.S.) is convinced that the high-frequency energy than treated as transmission lines,
radiated emissions of the others do. The second way then it is important that the line
modified product meet the relates to the effect of the anten- is terminated in its characteristic
required specification limits. nas (that is, the circuit intercon- impedance. Antennas can also
Also note that for the FCC, if nections) that the high-frequency be formed by long traces that are
the system contains a clock with energy sources are connected to. driven by ground voltage noise
a frequency above 108 MHz, it The third way is by the shielding and therefore radiate. Even a
must meet the FCC limits for that the chassis box provides and ground plane, when driven by a
radiated emission frequencies by the cable shields that effec- ground noise source can radiate.
up to 2 GHz. Most ATM (con- tively reduce the amount of Often, cables can radiate energy
4

when high-frequency currents 875 MHz. At 875 MHz, a slot radiation. This often happens at
flow through them. Since cables big enough for a duplex SC box joints and seams, and care
are often the largest antenna connector fiber-optic module must be taken to prevent radia-
around, they are usually the (3.05 cm / 1.2 inches) would tion in these areas. EMI gaskets
dominant source of radiation. provide 15.0 dB of shielding. At are often used in seams and
Chassis and cable shields can 875 MHz, a slot big enough for joints to make sure that the
also radiate if ground noise a simplex ST connector electrical contact across the seam
current or voltage drives them. fiber-optic module (1.27 cm / 0.5 and joint is continuous. In this
Fiber-optic cables do not, how- inches) would provide 22.6 dB of manner, long radiation holes,
ever, radiate energy as wire shielding. Thus the 1x9 module which otherwise might form
cables do. Therefore, fiber-optic duplex SC hole provides 2.5 dB
Eq. 1 between the screw/bolt locations
cables can help reduce radiated more shielding than the MIC that hold the seam or joint
emissions if using wire cables is FDDI connector hole does. If together, if no gasket were
a problem. At FDDI and ATM the radiation were at 437.5 present, are prevented. Good
data rates, the encoding/ decod- MHz instead of 875 MHz, then conduction is necessary for good
ing schemes, and the consequent each slot would provide an shielding. Metal works the best.
additional circuitry, needed to extra 6 dB of shielding. (The Some conductive spray paints or
reduce the bandwidth and the wavelength at 437.5 MHz is metal coatings can help and may
emissions on a twisted pair wire twice that at 875 MHz. This be able to approach a metal wall
cable, are not needed if a doubling of λ gives a 6 dB in the best case. Very-low-
fiber-optic cable is used. increase
(3*1010) in shielding (Eq 1). If frequency magnetic fields often
there are =multiple
34.3 cm/13.5 inches
identical need exotic high-permittivity
If an antenna is completely
875*106
openings in a shield, then the materials such as mu-metal to
enclosed in a sufficiently thick total radiation is increased by: attenuate these magnetic fields.
metal box, then no radiation will A conductive wire sticking
escape. If the box has an aper- 20log10√n dB where n is the through an opening can pick up
ture, then some radiation will number of openings. radiation inside the box, conduct
escape through it. The bigger This formula assumes the the noise to the outside of the
the opening and the higher the openings are close together box, then reradiate the energy,
frequency, the more radiation (within
21 = 20log √n + 20log10 nThus
1/210wavelength). completely defeating the shield-
that escapes. If the antenna is two ST connector openings ing provided by the opening,
sufficiently far enough away = 30log
would allow n dB more radia-
10 3 were it empty. A fiber-optic
from the opening, then the tion to escape than one opening module with a metal nose can
theoretical far-field attenuation This formula is derived from the often conduct radiation outside a
would. This is the reason why a
by a rectangular opening (slot) in shielding formula for multiple
duplex SC connector opening chassis if it has a section of the
a shield is: holes in a chassis plus the metal housing that sticks out of
has 22.6-15-3=4.6 dB less
increase in radiation for multiple the chassis and if that metal
λ shielding than two ST connector
modules
20log10
2l
Eq. 1 openingsadding in phase.
do (if the An
ST openings housing is not tied to the chassis.
equivalent way of expressing
are not too close to each other). The HFBR-510X/520X fiber-optic
where λ is the wavelength and l this formula is: transceivers have plastic hous-
is the largest linear slot These shielding formulas are ings and do not conduct radiation
dimension. (21/30)
n = 10 if the =source
5 outside of the chassis in this
invalid is too close
to the opening, if the openings manner.
For example, at 875 MHz the If the modules’ phase is
are so close together that they
wavelength is: uncorrelated
appear as onedue big to each
hole, or concen-
if External shields can be added to
trator having its own clock
there is any conductor sticking provide additional shielding. An
source, then perhaps the
through the opening (in which example of this would be an
(3*1010) modules’ radiation would
case it really should not be r.m.s external conductive vanity cover
= 34.3 cm/13.5 inches
6 add. have: over the fiber-optic ports to allow
875*10 calledInanthis case weThe
opening). would
shield-
by the longest all the fibers to escape in a
10√n + 20log10 √n
A slot big enough for an FDDI ing
21 =is20log
determined
bundle through a relatively small
MIC connector fiber-optic module linear dimension of the opening.
= 20log n exit access hole. This hole
10/√n
20log
(4.06 cm 1.6dB wherewould
inches) n is the Thus, even10 a very thin, but long
provides additional shielding. If
provide 12.5number of openings.
dB of shielding at hole could leak quite a lot of
n = 10(21/20) = 11 the hole is a tube with the length

21 = 20log10√n + 20log10 n
5

longer than the diameter, a Since there are so many factors the presence of an external
waveguide effect occurs and the that affect radiation and since electromagnetic field relative to
radiation is drastically reduced many of these factors interact the performance with the
as it travels through this tube. with each other, radiated electromagnetic field absent.
See Reference (3) for details. emissions can be the most tricky The measurements must be
The waveguide phenomenon, for EMC problem and should be made over a variety of electro-
example, can be quite effective, considered as early in the design magnetic field strengths and
but it is sometimes difficult to as possible. It is often difficult to frequencies. Then the same
implement such a structure in fix a radiated emissions problem product performance is mea-
practice. (Such structures can, once the system design has been sured with the electromagnetic
while reducing the radiated completed and is near field turned off.
emissions, make it so much more production. Using good
difficult to remove the fiber-optic shielding, good high frequency Immunity and susceptibility
cable connections in the field as PC board layouts, good cabling, refer to the same characteristics
to make their overall product and good low-emission circuit (immunity is the inverse of
contribution questionable. For components, such as the susceptibility). From a measure-
example, a door may have to be HFBR-510X/520X fiber-optic ment point of view, however,
opened up, the fiber connector transceivers, will help ensure the what is measured is the perfor-
disconnected, and then slid radiated emissions compliance of mance penalty due to the elec-
through a waveguide tube in the final product. Additionally, tromagnetic fields and this
order to disconnect the fiber from if the EMC performance is penalty is the susceptibility.
the communication system. This considered early in the product The goal is to have zero perfor-
is much more difficult than design and if low radiated mance penalty or zero suscepti-
merely unplugging a fiber from a emission components are used, bility, i.e. totally immune.
module port that is accessible then the designer may find that
directly through a hole in the less stringent shielding can be At the system level, only a few
chassis back panel. The used in the final product. Less written specifications address
HFBR-510X/520X fiber-optic stringent shielding is often susceptibility (immunity). The
transceivers’ low-radiated easier to manufacture and is authors of the IEC 801-3 specifi-
emissions make the need for lower in cost. Thus, less cation (see Reference (7)) have
elaborate structures, such as stringent shielding can lower the stated that the computer system
waveguides, to reduce emissions overall product cost. For product under test should be
much less necessary.) example, a conductively coated immune to 1 to 10 V/m external
plastic chassis that needs no fields. They define three classes
If noise is induced in the shield, extensive EMI gasketing can be of devices. Class 1 is a 1 V/m
it can radiate. This problem is cheaper to make than a metal susceptibility test for devices
usually avoided by the “skin chassis with many EMI gaskets. that are expected to be used in
effect” which keeps most shield Thus, low radiated emission low level electromagnetic field
noise currents on the inside of components, such as the environments. Class 2 is a 3 V/
the box, close to their sources, HFBR-510X/520X fiber-optic m susceptibility test for moder-
while no noise current flows on transceivers, can allow the ate environments. Class 3 is a
the outside of the box. If the product designer to make a 10 V/m susceptibility test for
shield is directly connected to lower-cost product that still has environments with severe
some noise source, there will be good radiated emissions electromagnetic radiation
problems. Also resonances can performance. present. What is meant by
occur inside a box; and depend- immune (i.e. how much penalty
ing on the dimensions of the box, 2.2a What is Susceptibility is allowed) however, is left
a standing wave can form. (Immunity)? unclear and is said to be nego-
Radiation at this standing wave Electromagnetic susceptibility of tiable between vendor and
frequency can be amplified inside a product (or immunity) is customer. Based on some of
the enclosure. The dominant defined as the effect of external Hewlett-Packard’s customer
frequency of the radiation from a electromagnetic fields on the inputs, HP has standardized on
chassis can often be at its resonant performance of that product. a 10 V/m field strength to test
frequency. The performance is measured in fiber-optic transceivers. Thus
6

HP modules are tested to the that in reality a 5 V/m field sources of radiation that could
Class 3 IEC 801-3 severe envi- might be the most that would be conceivably cause susceptibility
ronment test level. This is a seen from a walkie-talkie). problems. And, of course, compo-
large field strength and would be nents with high immunity (or low
difficult to generate inside a Usually an antenna in the circuit susceptibility) should be used
computer system unless the will pick up the external field whenever possible.
source is within inches (or and then couple it into a critical
centimeters) of the circuit in circuit node where it appears as Generally speaking, a 10 V/m field
question. Or it could be gener- a noise signal. The susceptibility strength will not occur very often
ated by a very large ESD or by a will depend on the frequency of but is a reference level to use for
very-high-power radio transmit- the field because the receiving susceptibility testing. Components
ter (walkie-talkie) that is held antenna gain varies with fre- that can withstand a 10 V/m fields
very close to the system. quency and because the circuit and maintain their designed
noise rejection varies with performance should not create any
As an example of how large a 10 frequency. The noise can be susceptibility problems when used
V/m field is, consider that the picked up directly at the sensi- in a communication system. The
FCC B radiated emissions limit tive node itself or can be con- system designer can be confident
is 46 dB µV/m at 500 MHz at a ducted from another node (such that the other components in his/her
test distance 3 meters from the as Vcc) that has a larger gain system, most external radiated field
source. This is a 1 µV/m *10(46/20) antenna connected to it. sources, and most ESD strikes (that
= 199 µV/m field strength. The far do not conduct current directly
field strength varies as a function of Performance degradations due to through the component itself), are
1/r, where r is the distance from incident electromagnetic fields can not likely to affect the performance
the source. Thus, at a distance occur as lines appearing on CRT of these 10 V/m immune compo-
of 1 cm (0.39 inches) from the displays, noise/other channels nents in any significant manner.
source, the field strength would appearing on a radio broadcast The HFBR-510X/520X fiber-optic
be 300*199 µV/m = 0.06 V/m . reception, larger than normal bit transceivers are a good example of
This is still 20log10 (10/0.06) = error rates in digital networks, or such a 10 V/m immune component.
44 dB less field strength than a state machines getting mixed up
10 V/m field. Therefore, to and the whole system becoming 2.2b How System Design
generate a 10 V/m field at the locked or just behaving strangely. Affects Susceptibility
fiber-optic receiver would require Susceptibility problems are bother- (Immunity).
a source, which on its own would some to the end users because it is For this discussion we will
fail FCC B by 44 dB, to be placed often difficult for them to fix the concentrate only on the effects of
within 0.4 inches (1 cm) of the problem (or even to get it to occur the external electromagnetic
receiver. Clearly not too many often enough in order to try to fix it). field on the fiber-optic module
such sources can be present in a Many systems have built in error circuitry although other circuitry
computer system which must correction and error trapping can also be affected by an exter-
pass FCC B limits. So, practi- routines so that if some strange nal field. The effects will vary
cally, a 10 V/m field can be error does occur at least the only from circuit to circuit. But this
generated only by a large thing the user might experience is susceptibility discussion, concen-
high-frequency current pulse, the extra delay caused by the time trating on fiber-optic receivers,
such as an ESD pulse, or by a it took the system to catch and will hold true, in general, for
high power nearby radio/TV recover from the error (and possibly other circuits as well.
transmitter. The example in the retransmit the data).
IEC 801-3 specification indicates The usual effect of an external
that a 10-watt walkie-talkie held Obviously, the less often these field on a fiber-optic receiver is to
at 1 meter from the HP module susceptibility problems occur, the degrade the received bit error
(with no shielding provided by better. When components with rate. The fiber-optic receiver
the system chassis) would low-radiated emissions are used (Rx) is usually the most sensitive
generate a 5 V/m field. This is inside the system, such that the analog circuit in the entire
the largest field strength indi- system can pass the radiated communication network product.
cated on the IEC 801-3 Figure emissions requirements easily, then An external field can induce a
A.3 curve, (so one would assume there are fewer possible large signal on the antennas formed by
7

the interconnections in the from. The field could be caused the ESD strike will generate. The
fiber-optic Rx circuitry. Anten- by an ESD. The ESD currents lower the peak ESD current is (if it
nas are bi-directional devices. flowing in the antennas formed can be limited somehow), the lower
The same phenomenon that by the chassis and/or other the field strength that will be
causes an antenna to radiate an circuitry generate the field. The generated. Also, if the frequency
electromagnetic field when a external fields could be gener- characteristics of the ESD strike can
voltage/current signal is applied ated by other equipment outside be lowered in frequency (by limiting
to its inputs, will generate the the chassis, but nearby, such as the ESD current pulse rise and
same voltage/current signal at radio or TV transmitters. The falling edges), then the strength and
those inputs, (now really the external fields could also be the frequency of the ESD generated
outputs), if the same antenna is caused by other circuitry inside field can be lowered. If, in addition,
placed within an identical, but the system chassis, if that the ESD current does not flow
externally generated, electro- circuitry is located nearby the inside the chassis, it will generate a
magnetic field. The antenna, fiber-optic Rx. larger field on the outside of the
formed by the Rx circuit inter- chassis than on the inside of the
connections, picks up the exter- Fields which must pass from chassis. Thus, in the case where the
nal field and generates a signal. outside the chassis to the inside are ESD current flows only on the
If the generated noise signal is attenuated by the chassis shielding. outside of the chassis, the chassis
conducted to a sensitive circuit The shielding by the chassis, to a shielding will help shield the circuit
node, the node then experiences field external to the chassis, is the inside from the ESD-generated
a lower signal-to-noise ratio, same as the shielding provided by field. Most designs try to prevent
which increases the bit error the chassis to exiting radiation as ESD current flow through the
rate. (In a perfect fiber-optic Rx, was discussed in section 2.1b. So if printed circuit board grounds inside
the signal-to-noise ratio and the the field has to pass through only the system in order to reduce both
bit error rate are directly re- one 1.2 inch (3.05 cm) hole in the the ESD generated fields inside the
lated). So the external electro- chassis to get inside, then it will be chassis, and the chance of compo-
magnetic field can inject noise attenuated by 26.4 dB at 237 MHz nent damage due to ESD current
into the fiber-optic Rx and thus relative to the outside field strength. flow.
degrade the bit-error rate (BER). So, in this example, a 10 V/m
outside field strength would be Any noisy components near the
Obviously, the larger the field equivalent to a 0.5 V/m field sensitive Rx could cause prob-
strength is, the bigger (higher gain) strength inside the chassis. Many lems. The fiber-optic Tx is
the antenna is, the better the chassis, however, do not provide shielded, but it is still the closest
coupling to the sensitive node is, that much shielding. Also, if the high-current circuit to the Rx.
and the more sensitive that node is circuit is very close to the hole, the When the transmitter in a
to noise, the worse the overall shielding will be less than the 26.4 transceiver operates, it is pos-
susceptibility of the Rx will be. The dB at 237 MHz value that is sible that it could affect the BER
HFBR-510X/520X fiber-optic calculated, based on the assumption of the receiver that is located
receivers have been designed with that the receiver is far away (in the next to it inside the transceiver.
these concepts in mind to ensure far field) from the hole (that is, the The Tx could conductively couple
that the Rx can operate under a source). In addition, the farther the or radiatively couple noise into
large electromagnetic field strength component is from the hole in the the Rx. The Tx-to-Rx crosstalk is
with only a negligible effect on the shield, the lower the external field defined as the change in receiver
BER. But, at the equipment level will be at the component because sensitivity (in dB of optical input
containing many components, how the field strength rolls off (at 1/r) as power) with constant BER, when
can the system design affect the the distance, r, from the source the transmitter is operating
overall system performance (BER increases. versus when the transmitter is
etc.) for a certain end-use environ- off (data inputs held at constant
ment known to contain electromag- As we have said earlier, ESD can dc levels). Hewlett-Packard has
netic fields of certain frequencies generate fields. The shorter the tested the HFBR-510X/520X
and field strengths? path (from the strike contact point fiber-optic transceiver Tx to Rx
in the system to earth ground) that crosstalk and found that it is
The first thing to consider is the ESD current flows through, the negligible (it is typically 0.0 dB
where this external field comes lower the strength of the field that and easily less than 0.1 dB worst
8

case). This result makes sense that systems can have additional certain voltage, which implies a
because the Rx susceptibility is guardbands for noise by using certain amount of stored charge,
practically zero, the Tx radia- large amplitude signals. Most in series with a resistor (R) and
tion level is very small, and logic-level signals (like ECL an inductor in order to model the
therefore, the radiated coupling outputs) are large enough in conductor dc and ac discharging
between the Tx and Rx is amplitude that the noise gener- impedance. The human body is
extremely low. Hewlett- ated by the external field will modelled relatively well by a
Packard has also designed the have negligible effect on the small C and a large R. The
Tx and Rx to prevent crosstalk circuit operation. Any fiber-optic machine or metal body model is
due to conducted (Vcc and Rx, if operated at optical input under more debate within the
ground) paths. power levels a few dB above its industry but usually has a large
sensitivity limit, can withstand C and low R (and thus has a
If there is a sensitive circuit in more noise without degrading higher discharge current than
the system, precautionary steps the BER above its specified limit, the human body).
can be taken to make it less than it can if the optical input
sensitive to electromagnetic power is at the sensitivity limit. 2.3b How System Design
fields. One step is to add an Affects ESD.
additional shield over the 2.3a What is ESD? As mentioned above, ESD can
sensitive circuit. Since the Certain non-conductive materi- affect a product during its
fiber-optic Rx in the als can either donate charge manufacturing or during its
HFBR-510X/520X already has a (electrons) or acquire charge operating lifetime. Usually,
very good shield built in, this when in contact with other during manufacturing, the
will not be necessary. Another materials. A material with a net various components in the
step is to make sure that the charge can then transfer it to a equipment are less protected
Vcc and ground and I/O lines conductive material either by from ESD than when they are
are short to prevent noise from direct contact or by inducing the installed in a fully assembled
coupling in. HP tests the opposite charge in the conductor. system. The use of ESD reduc-
susceptibility of the If this charged conductor con- tion techniques can help mini-
HFBR-510X/520X Rx in a test tacts an earth ground (or any mize ESD damage to the exposed
breadboard that has the typical conductive body with a very components. Workers reduce the
data sheet (Reference (1) and large amount of stored charged chance and amount of ESD by
(2)) Vcc power supply filtering available), a current will flow wearing grounding straps on
circuit and also has typical until that conductor’s net charge wrists, by wearing conductive
input/output line lengths. So, becomes zero. For example, if smocks, by using conductive
any possible effect on the Rx your skin is charged from walk- mats on surfaces, by using
due to the coupling of the field ing across the carpet on a cold anti-static packaging to keep
into the I/O lines or the Vcc or dry day and you then touch a ESD off sensitive components,
ground lines in a real applica- grounded or large conductor, you and by using anti-static devices
tion circuit is accounted for in may see a spark as your skin or equipment that reduce the
the susceptibility test. discharges, and feel a tingle in static in the air or on surfaces.
your finger, as the current flows.
Another way to make a system The characteristics of the ESD Since a system usually consists
more immune to external fields current depend on the amount of of various components and
is to make the system respond charge stored and on the imped- subassemblies, each with differ-
elegantly to any noise that is ance of the circuit that dis- ent ESD tolerance, the ESD
picked up. Approaches such as charges it (to ground). capacity of each item in each
error detection and correction stage of the manufacturing
hardware and/or software, or Products are usually specified in process must be known in order
merely a request for retrans- terms of how much electrostatic to guarantee that each item can
mission, in case the received discharge they can withstand be handled safely during the
errors are not correctable, are without damage. Usually two manufacturing process. If all the
possible ways to be more types of discharging conductors ESD events are controlled during
immune to the effects of noise. are modelled. Each conductor is manufacturing so that they lie
The other thing to consider is modelled as a capacitor (C) at a safely within the limits of the
9

most ESD-sensitive components, inside a conductive or nents of conducted noise. First is


then the system can be manufac- static-dissipating chassis box in the conducted noise generator.
tured without ESD damage. the end product, then ESD is Second is the path that the noise
more likely to go to the conduc- takes to conduct from the genera-
In a finished system, ESD can still tive box than to some other tor circuit to the receiving circuit.
cause permanent product damage. non-conductive component. For Third is the sensitivity of the
Often, however, a more important example, if a plastic-nose, receiving circuit to this noise.
problem is ESD disturbances to the fiber-optic module is protruding So, conducted noise problems
system performance. An ESD from the chassis box, then ESD could be eliminated by eliminat-
performance disturbance could is more likely to be conducted to ing the noise source, removing
include things such as lines on a the section of the chassis box the conductive path, or by using
CRT display, logic getting stuck in a that is near the module nose circuitry that is insensitive to the
locked state, or a larger number of than it is to be conducted to the effects of conductive noise.
bit errors than usual. These ESD insulating transceiver’s
disturbances can be accounted for in plastic-nose itself. If the chassis Since an actual fiber-optic
the system design in order to ensure grounding is such that the ESD communication network has
that the product’s end user does not currents to ground flow on the many different types of circuitry,
notice any drastic performance chassis and do not flow inside all operating at once, it is impor-
differences when an ESD event does the PCB component grounds, tant that potential conducted
occur. then ESD damage or ESD noise problems be minimized to
problems due to radiated fields allow all the circuitry to operate
The HFBR-510X/520X fiber-optic caused by the ESD pulse will be without any section of it being
transceivers are shipped in a reduced. One such scheme to adversely affected. In addition,
low-cost anti-static shipping tube keep ESD currents only on the most computing products have
to prevent ESD during shipping chassis is referred to as a limits on how much conducted
and handling. The tubes protect single-point grounding scheme noise they are allowed to gener-
the transceivers until they are because the chassis and the ate on the 120 Vac power lines to
removed and assembled onto the circuit grounds connect at only prevent them from disturbing
PC boards. The end-use applica- one point. other devices connected to the
tion PC boards often provide same ac power line. Since this ac
additional protection to the 2.4a What is Conducted power-line-conducted noise
module from ESD after the Noise? problem is determined more by
module is soldered onto the PC The fourth EMC area is con- the overall product’s power
board. This additional protection ducted noise. Ideally a conduc- supply circuitry and filtering and
comes about from the terminat- tor will carry only the desired is not very much affected by the
ing impedances found on most of signal. Practically, however, fiber-optic transceiver that might
the transceiver input and output there is always some component be operating in the product, the
lines on the PC board. These of the actual signal on the ac power line conducted noise
terminating impedances divert conductor that is undesirable. will not be discussed in this
some of the ESD current that This component is defined as application note. Hewlett-
would otherwise flow into an noise. Conducted noise ema- Packard has taken steps in the
unprotected module pin. Fur- nates from one section of the design to minimize the noise that
thermore, PCB can be designed product’s circuitry, and is con- is generated by the HFBR-510X/
with guard rings around the ducted to the section of the 520X modules. Therefore the
edge of the board. The guard circuitry being observed. A good probability of any possible
rings are connected to chassis example is the switching noise in disturbance from these modules
ground when the board is in- the power supply line (Vcc) of a on the ac power line has also
stalled in the system. The guard digital (logic gates) circuit being been minimized.
rings divert currents to the conducted over to a sensitive
chassis-ground in the event of an analog (amplifier) power supply 2.4b How System Design
ESD, thus reducing the chance of line and adversely affecting the Affects Conducted Noise.
damage. analog-circuit’s performance. Conducted noise can be gener-
ated by switching power sup-
If the components are enclosed There are three main compo- plies, digital logic gates, light-
10

ning transients, and other noise able that have been designed to noise better than single-ended
on the ac power lines. Usually be quieter. ECL is designed with outputs do because the Vcc and
the low-frequency noise is differential current sources that ground noise is effectively
handled by filters and transient tend to maintain a more con- reduced. The Vcc and ground
absorbers in the power supply. stant power supply current noise is common to both of the
Switching power supplies can be during switching. The differential digital outputs.
designed to have as low a noise HFBR-510X/520X fiber-optic Therefore, when the two outputs are
output as is possible. Digital transceiver uses extensively subtracted from each other, to find
logic gate noise can be reduced differential current switches and the differential output voltage that
by having good decoupling ECL output stages, similar to determines the output logic state,
capacitors with short lead those used in the ECL family. the common-mode noise on each
lengths between Vcc and ground Thus the HFBR-510X/520X output, to first order, is canceled
near the logic gates. Vcc and fiber-optic transceiver generates out. Hence, the common-mode Vcc
ground planes in a multilayer low amounts of Vcc noise due to and ground noise does not appear in
printed circuit board reduce the its almost “dc” power supply the final differential output signal.
Vcc and ground effective lead current. Analog circuits can be designed to
lengths and thus reduce the reject noise by adding filters and by
amount of Vcc and ground noise. Besides filtering and reducing trying to use differential signal
the noise sources, sometimes techniques where possible.
Sensitive circuits can have problems can occur from shared
additional power supply filtering Vccs or grounds. If a sensitive 3.0 Summary of
circuits that reduce the noise circuit is upstream from a digital HFBR-510X/520X
before it gets to the sensitive logic gate generating Vcc noise,
Component Level EMC
circuit. Depending on the noise its power supply voltage will
frequencies, different values of bounce when the digital logic Performance
filter capacitance can be tried to gate switches and draws current.
eliminate the noise frequency If the sensitive circuit has its The results show that the EMC
over a wide bandwidth. Usually, own separate Vcc or ground line performance of the HFBR-510X/
for a group of ICs on a PC board, or plane it won’t detect this noise 520X is excellent and should
some 0.1 µF and 10 µF Vcc due to the other digital logic therefore make the customer’s
filtering capacitors will help gate. But, if two circuits need to EMC design easier.
reduce Vcc noise over a reason- talk to each other, often their
ably wide bandwidth. For low Vccs and grounds should be A. The module typically passes
frequencies, some resistance in common so that there are no worldwide emissions limits for
the power supply line, plus a noise differences in Vcc or class B by more than 10 dB.
large capacitance, low frequency ground between the two circuits Therefore, one unit in a com-
bypass capacitor can act as an that can act as equivalent noise puter system will not cause the
effective low-pass power supply sources. system to fail radiated emissions
filter. Inductors and ferrites can to the worldwide B test limits no
also be used in power supply An additional approach is to try matter how poor the shielding is.
filters to add additional filtering circuits that are not too sensitive
if needed. to Vcc or ground noise. Digital B. The susceptibility is basically
logic gates are a good example of zero for 10 V/m fields. Because
Some digital logic families this because they have a good of the module’s high immunity,
generate more noise than others. deal of noise margin. Therefore, the customers need not worry
Within a given logic gate family, they can tolerate a fair amount about the effects of nearby
usually the faster the logic gate, of noise before it causes them to circuits on the receiver (Rx).
the more noise it will generate. misread a logic state. Differen- Fields external to the system are
Logic families with totem pole tial outputs also help because also not an issue. Only very
outputs, such as TTL and CMOS, the follow-on logic switches when large ESDs could generate a 10
can draw large spikes of Vcc the two data outputs cross. This V/m field, so the concern about
current during switching, thus crossing point is first-order ESDs causing bit-error rate
creating Vcc noise. There are independent of Vcc and ground problems is minimized.
newer families of CMOS avail- noise. Differential outputs reject C. The module is a Class 1 ESD
11

component and so should be finished-product performance, gree increments, the turntable on


handled in a Class 1 ESD envi- when that component is used as which the module was placed.
ronment. It withstood 1800 volts intended in the finished product. The entire radiated emissions
and therefore missed the Class 2 Since the actual end-usage EMC frequency range, as determined
classification limit by only 200 performance is determined by by the particular test antenna in
volts. Using the machine model many factors in the overall use, was observed during these
EIAJ test it withstood 100 volts. system, the usual approach is to tests so that the worst-case peak
When the transceiver is installed use some conceivable worst-case at each frequency could be found.
in the application circuit, it can condition to determine the The antenna and test system
withstand a 25 kV zap to any- component-level EMC test calibration factors were then
where on the module without conditions. Then either guaran- used to derive the peak radiated
permanent damage. tee that the component will electrical field strength being
never experience such a emitted, at each frequency, from
D. In a real application circuit, worst-case condition in the end that module at that test distance.
50 mVp-p of Vcc noise should environment or use that worst Each radiation frequency was
cause no more than a 0.3-dB case plus known facts about how then quasi-peaked for those
sensitivity penalty, no matter the actual end environment frequencies below 1 GHz.
what the Vcc noise frequency is. differs from the worst case to
Most Vcc noise frequencies will predict the actual system perfor- These final worst-case field
cause zero penalty. mance. strengths were then compared to
the relevant specification limit.
E. The transmitter (Tx) to 4.1a Radiated Emissions The worst-case margin to the
receiver (Rx) crosstalk is also Testing Procedure specification limit is the smallest
basically zero. Thus the Tx in The HFBR-510X/520X fiber-optic difference between a worst-case
the transceiver can operate with modules under test were placed final radiation level and the
any data pattern and not disturb in an electrical-loopback test specification limit, over the
the BER of its neighboring breadboard and were tested to entire specified frequency range.
receiver under any conditions. find their radiated emission Note that because both the
spectrum using the FCC certified radiation levels and the limits
4.0 HFBR-510X/520X semi-anechoic test chamber at vary with frequency, the highest
Component-Level EMC Hewlett-Packard’s Cupertino radiation level will not necessar-
Testing site (CA). This test chamber is ily give the worst-case margin. A
used by various Hewlett-Packard log periodic antenna is used from
The electronics industry EMC divisions to test their products to 200 to 1000 MHz. A biconical
standards are often not defined FCC and other emissions limits. antenna is used from 30 to 250
and are sometimes non-existent The tests are mostly automated MHz. Above 1 GHz a horn
at the component level. Most and are conducted by qualified antenna is used. Note that the
EMC specifications apply to personnel. FCC and other regulatory
system-level products only. agencies do not regulate radiated
Therefore, Hewlett-Packard has For the FCC Class-B tests, the emissions below 30 MHz.
tried to generate its own test antenna was placed at a
component-level EMC specifica- 3-meter test distance from the A standard HFBR-510X/520X
tions. A good component level module. For the FCC Class-A, transceiver module outside the
EMC specification must accom- CISPR 22, VCCI, or EN 55022 test chamber provided a 125
plish two goals. First, the tests, the test antenna was Mbaud or 155 Mbaud 1010
specification must be relatively placed at a 10-meter test dis- pattern optical signal. This
easy to measure, and the mea- tance from the module. The optical signal was used to drive
surement must be repeatable worst-case peak field strength the Rx of the HFBR-510X/520X
and accurate. Second, the radiated emissions were found transceiver module in the
component performance mea- by moving the antenna up and loopback test breadboard inside
sured must have a clear relation- down from 0.1 to 4 meters in the test chamber. The loopback
ship to the performance of the height, by changing from vertical test board uses the power supply
component, and its consequent to horizontal antenna polariza- decoupling circuit recommended
effect on the overall tions, and by rotating, in 45-de- in the data sheet . The Rx drives
12

the Tx using a 2.7 inch (6.86 cm) tracting a fixed 1.5 dB value to chamber ensures results that can
long connection between the Tx get an approximate final be used directly to determine
and Rx data and data * pins. quasi-peak result. Above 1 GHz, FCC qualification. Problems due
(The actual Rx to Tx lines go 1 no quasi peak detectors exist. to resonances in TEM cells are
inch (2.54 cm) up and back, and Therefore, the FCC B test above eliminated. (A resonance can
go 0.7 inch (1.78 cm) across.) 1 GHz uses the peak radiation give large radiation test errors by
This connection length was believed value directly and adjusts its amplifying the radiation at the
to reflect the approximate length of specification limit accordingly. resonant frequency.) Since the
a connection, from the Rx to a PHY The radiation frequencies seen test facility is automated, we can
circuit, and then back from the PHY for this test consist of harmonics test modules and conduct experi-
circuit to the Tx, in a real applica- of the fundamental frequency of ments relatively quickly. We
tion printed circuit board. The 50 the 1010 data pattern. The have also tested modules inside a
ohm to Vcc-2 Volt equivalent (split fundamental frequency of a 1010 simulated metal chassis box and
load) terminations were placed at pattern is equal to one-half the have verified that our plastic
the Tx inputs. The board has a 2.5 data rate. Thus the 125 Mbaud nose modules do indeed get close
by 2.9 inch (6.35x7.37 cm) ground radiation test has radiation to the theoretical shielding limit
plane with through-hole compo- frequencies that occur in integer predicted from the size of the
nents and hand wiring. Coaxial multiples of 62.5 MHz. hole in the shield.
cable with ferrites (plus a coiled
section) brings in dc power. The The worst-case quasi-peak Hewlett-Packard radiated
shield of this dc power supply cable radiated field strengths for each emissions tests are designed to
keeps any radiation from adding to frequency are compared with the be as close to real life as is
the test result. Thus, any radiation FCC and other regulatory possible, so that the results can
seen in this test is due exclusively to agencies specified limits. These be correlated to final customer
the fiber-optic transceiver module test limits vary with frequency. results. An attempt was made to
and to any interaction it might have The margin (positive if pass, design a test board that realisti-
with the test board. negative if fail) by which the cally mimics a typical best-case
final worst-case, quasi-peaked if customer layout. HP would like
The final margin to the FCC and necessary, field strength passes the results of the radiated
other regulatory agencies specifi- the test specification is the test emission tests to be such that
cation below 1 GHz was obtained margin of the component to the even if a customer provides no
by quasi-peaking each emission FCC and other regulatory shielding, one of the HP
peak at each frequency according agencies limit at that frequency. HFBR-510X/520X transceiver
to the FCC requirements. The final overall FCC and other modules will not cause the
Quasi-peaking allows devices regulatory agencies test margin customer to have typically less
such as printers, which put out for that component is the than 6 dB margin to any of the
radiation only in short bursts worst-case (smallest) margin, worldwide B limits. Most cus-
(when a print head turns on), a over the entire specified fre- tomers want their system to pass
break by averaging the radiation quency range. It is this final test worldwide B by 6 dB. HP’s goal
energy over a specified period of margin that is used by the FCC was therefore to pass FCC B by
time. For a fiber-optic module and other regulatory agencies to 10 dB. Since CISPR 22B, EN
with a 1010 pattern that puts determine whether the product 55022, and VCCI Class 2 Europe
out continuous radiated energy, passes the specification or not. and Japan B limits are roughly 3
quasi-peaking drops the peak So the final FCC and other dB tougher for our fiber-optic
radiation level by a small fixed regulatory agencies test margin modules to meet than FCC B is,
amount. Since quasi-peak is the worst-case (quasi-peaked meeting FCC B by 10 dB ensures
testing takes more time, only the below 1 GHz) margin of the 7 dB to worldwide B.
worst radiation peaks are detected field strength to the
quasi-peaked. Some of the limit for any radiation frequency In an actual system, the chassis
lower-level radiation data is in the specified range, any moduleshielding will often greatly
approximated to an equivalent orientation, any antenna height and
reduce emission. So, in a
final quasi-peak result from the any antenna orientation. well-shielded system, many
peak result by taking the actual modules could be used (in a
peak emission result and sub- Use of a calibrated semi-anechoic FDDI concentrator or ATM
13
Eq. 1

switch, for example). If we get office equipment (Class B) and means that actual test data was
21 dB of shielding at 437.5 MHz therefore the previous analysis not available. Based on other
from a 1.2 inch (3.05 cm) duplex may be too conservative. No data, however, the NA results have
SC hole in a chassis, then we
10)
matter what the real limit on the been approximated and those
(3*1021
have dB morecm/13.5
margininches
to work number of units in concentrators estimates are listed in parenthesis
= 34.3
875*10 6
with. In a concentrator, if all the is, we feel that we have done our with an approximate sign.
modules’ energy were in phase best to ensure that our radiation
and therefore directly added is as low as possible to ensure Figure 1 shows the final emis-
20log10√n
together, 21 dB where be
dB would n isenough
the that the largest number of sions data for the HFBR-5103/
number
for n modules, whereof nopenings.
is found modules can be used in concen- 5105/5204/5205 1300 nm trans-
from: trator or switch applications. ceiver relative to FCC B limits at
Or perhaps the energy is not Very large concentrators can, if 125 Mbaud. Figure 2 shows the
21 = 20log10√n + 20log10 n necessary, add additional shield- final emissions data for the
ing, by the use of vanity covers HFBR-5103/5105/5204/5205 1300
= 30log10 n etc. to lower their radiation. A nm transceiver relative to FCC B
1010 pattern is the worst-case limits at 155 Mbaud. Figure 3
This formula is derived from the data pattern for radiated emis- shows the final emissions data
shielding formula for multiple sions. A psudo-random bit for the HFBR-5103/5105/5204/
holes in a chassis plus the sequence (PRBS) or varying 5205 1300 nm transceiver
increase in radiation for multiple pulse-width data pattern tends relative to the rest of world B
modules adding in phase. An to spread out the energy and (CISPR 22B, EN55022, VCCI
equivalent way of expressing lower the radiated emissions. Class 2) limits at 125 Mbaud.
this formula is: We use a 1010 pattern to be Figure 4 shows the final emis-
conservative and because a 1010 sions data for the HFBR-5103/
n = 10(21/30) = 5 is an FDDI IDLE pattern which 5105/5204/5205 1300 nm trans-
could be sent rather frequently ceiver relative to the rest of
If the modules’ phase is
in a real FDDI system. world B (CISPR 22B, EN55022,
uncorrelated due to each concen-
VCCI Class 2) limits at 155
trator having its own clock
4.1b Radiated Emissions Mbaud. Figure 5 shows the final
source, then perhaps the
Testing Results emissions data for the
modules’ radiation would r.m.s
The following results show that HFBR-5104/5203 820 nm trans-
add. In this case we would have:
the typical 820 nm and 1300 nm ceiver relative to FCC B limits at
21 = 20log10√n + 20log10 √n HFBR-510X/520X transceivers 125 Mbaud. Figure 6 shows the
= 20log10 n pass all the worldwide B limits final emissions data for the
by better than 10 dB margin HFBR-5104/5203 820 nm trans-
n = 10(21/20) = 11 below 1 GHz. Above 1 GHz, a ceiver relative to FCC B limits at
test board ground plane reso- 155 Mbaud. The bars on the
correlated; in which case, even nance causes the unit to pass plots in these figures show the
more modules could be used. FCC B by 7 dB above 1 GHz. tested final (quasi peak below 1
Thus, one unit will not cause a GHz) radiated field strength.
We have never tested a concen- computer system to have less The squiggly lines on the plots
trator or switch so we do not than 6 dB margin to any world- show the test system noise floor.
know exactly how the radiation wide B-radiated emissions test The test limit is shown as a solid
from all the modules in a concen- limit, even if no shielding is
Equations line labeled with the test limit
trator would add up. If any of provided by the customer chas- name.
our customers have insight in sis. (Remember that the FCC
this area that they would like to radiated emissions specification The radiation is usually a little
share with us, our applications is currently the only one that worse at 155 Mbaud than 125
department would be most requires testing above 1 GHz.) Mbaud. This is because there is
interested. We have seen FDDI The final emissions data is quasi more high-frequency energy
concentrators with many MIC peaked below 1 GHz and is just existing in (the fourier spectrum
connector modules. These the peak data above 1 GHz. of) the higher data rate signal.
concentrators have supposedly Table 1 shows a summary of the Also, sometimes, a 155 Mbaud
passed FCC classification for radiated emissions results. NA harmonic will be closer to a
14

Table 1: HFBR-510X/520X Radiated Emissions Test Result Summary

Optical Data Worst Worst Worst Worst Frequency


Wave- Rate case case case case in MHz
length Mbaud margin margin margin margin where
to FCC B to FCC A to World B to FCC B worst
(below 1 GHz) (below 1 GHz) (CISPR 22 B, (above 1 GHz) case
dB dB VCCI 2, dB margin to
EN55022B below 1 GHz
below 1 GHz) FCC B
dB limit
occurred
1300 nm 125 16.7 27.2 13.7 7.8 187.5
1300 nm 155 14.4 23.1 13.6 7.3 232.5

820 nm 125 14.9 NA (~25.4) NA (~11.9) NA (~7.8) 187.5

820 nm 155 13.1 NA (~21.8) NA (~12.3) NA (~7.3) 232.5


QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

55
ably conducted through the Vcc
FCC CLASS B TEST LIMIT (3 METER)
and ground connections, excites
the ground plane as an electric
45
(dipole/monopole) antenna. Since
the ground plane is acting as a
resonant antenna, the actual
35
amount of energy exciting it has
only a small effect on the amount
25
of the radiation. The frequency
of the radiation peak is right
around 1.3 to 1.4 GHz and a
15
quarter wavelength at those
frequencies is 2.3 to 2.5 inches
(5.84 to 6.35 cm). This is just the
5 size of the test board ground
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
FREQUENCY OF RADIATION PEAKS, MHz plane. Therefore, the ground
Figure 1. HFBR-510X/520X (1300 nm) radiated emissions at 125 Mbaud to
plane is acting as a one-quarter
FCC B limits. wavelength resonant antenna.
We have tried experiments in
resonant frequency than a 125 the 1300 nm modules. This
which we changed the size of the
Mbaud harmonic will be and this difference is still small enough to
test board ground plane, and
can cause the radiation to increase. allow any wavelength
found that the resonant fre-
The 155 Mbaud radiation peak at HFBR-510X/520X transceiver
quency of the radiation changes
232.5 MHz is just past the fre- module to still meet the data sheet
just as we would have expected,
quency where the FCC B and other claim of typically passing worldwide based on the ground plane size
limits suddenly increase. (FCC B B limits by 10 dB margin.
differences. We have also tried
increases 2.5 dB at 216 MHz and various fiber-optic modules in the
CISPR 22B, EN55022, and VCCI Above 1 GHz, the radiation
test board and have measured
Class 2 go up 7 dB at 230 MHz.) drastically increases. This is due
their radiation above 1 GHz. The
Below 1 GHz, the 820 nm unit is to a ground plane resonance
results are almost the same no
slightly worse than the 1300 nm effect on the HP test board. The
matter what module is being
unit by 1.3 to 1.8 dB. This increase board has a 2.5 by 2.9 inch
tested. So, any fiber-optic
in the 820 nm module radiation is (6.35x7.37 cm) ground plane
module seems to be able to excite
due to a known design difference with through-hole wiring.
the ground plane resonance. And
in the 820 nm modules versus Energy from the module, prob-
15

ground plane resonance to occur at


QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

55

FCC CLASS B TEST LIMIT (3 METER) 750 MHz. Our HFBR-510X/520X


modules have low enough radiation
45 levels so that we can see this ground
plane resonance occur without
having this phenomenon masked by
35 some other radiation source. Figure
7 shows the final emissions data for
the HFBR-5103/5105/5204/5205
25 1300 nm transceiver relative to FCC
B limits at 125 Mbaud using this
3x6" customer multilayer FDDI
15 PCB. More experiments need to be
done to further understand this
problem and how it affects our
5
1,400
customers.
0 200 400 600 800 1,000 1,200 1,600 1,800 2,000
FREQUENCY OF RADIATION PEAKS, MHz
The typical customer PC board is
Figure 2. HFBR-510X/520X (1300 nm) radiated emissions at 155 Mbaud
to FCC B limits. inserted into a backplane in a
chassis. Therefore the ground
QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

0-2 55 antenna structure, formed by the


FCC CLASS A TEST LIMIT (10 METER)
entire computer system ground
network, could by itself be effec-
45 tively much bigger than the board
CISPR 22B = EN55022 = VCCI CLASS 2 TEST LIMIT (10 METER) ground plane. Therefore, any
NO TEST DATA ABOVE 1 GHz WAS AVAILABLE resonances that may occur would be
35
at a much lower frequency than the
frequency calculated from the board
size alone. If the frequency is low,
25
the resonance may not occur at all,
may occur at frequencies that do not
15 radiate efficiently, or may occur
below the 30-MHz lower-frequency
limit for the radiated emissions test.
5 So, most systems will be safe from a
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
FREQUENCY OF RADIATION PEAKS, MHz ground plane resonance effect
Figure 3. HFBR-510X/520X (1300 nm) radiated emissions at 125 Mbaud (ground plane resonance could be
to 10 meter test limits, (FCC A, CISPR 22B, EN55022, VCCI class 2). excited by other ECL or other
once the ground plane resonates, radiated emissions? We have tested circuitry in the system, in addition
0-3 it dominates the overall radia- a customer’s multilayer FDDI PCB. to the excitement provided by our
tion. We are planning additional It reduced the radiation above 1 module. We therefore, have decided
experiments to make observa- GHz by 3.5 dB but it increased the to hold to our standard test board
tions regarding this ground radiation below 1 GHz (in the 750 results and those results are quoted
plane resonance issue. Our MHz area) by 5 dB. Thus, for the in this report.
applications and R&D depart- 1300 nm module tested at 125
ment is interested in any cus- Mbaud, the worst-case margin to 4.2a Susceptibility (Immu-
tomer experiences that may help FCC B was 12.1 dB (at 750 MHz) nity) Testing Procedure
us understand how this ground below 1 GHz and 11.4 dB above 1 To measure the susceptibility, an
plane resonance phenomenon GHz. Even with this different test external field must be generated
affects our customer’s radiated board, we still pass worldwide B by and the link BER must be
emissions. 9 dB. The multilayer PCB helped measured. A field can be gener-
the radiation above 1 GHz, but the ated by an antenna in a
How would it affect our customer’s larger PCB size (6" vs 3") caused the semi-anechoic chamber but this
16

QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

55
be used to test for radiation.
FCC CLASS A TEST LIMIT (10 METER)
Therefore we use the
semi-anechoic chamber for
45
radiation testing.
CISPR 22B = EN55022 = VCCI CLASS 2 TEST LIMIT (10 METER)

35
NO TEST DATA ABOVE 1 GHz WAS AVAILABLE A sine wave generator and a RF
amplifier provide the TEM cell
input drive voltage. A spectrum
25
analyzer detects the output
power from which the electric
field strength can be derived.
15 Sine wave generators from 10
MHz to 450 MHz are used to see
how the susceptibility varies over
5
frequency. A pure, unmodulated
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
FREQUENCY OF RADIATION PEAKS, MHz
sine wave is used. Modulating
Figure 4. HFBR-510X/520X (1300 nm) radiated emissions at 155 Mbaud the field, as is sometimes used in
to 10 meter test limits, (FCC A, CISPR 22B, EN55022, VCCI class 2). some product susceptibility tests,
does not make sense for our
QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

0-4 55 fiber-optic receivers. The fact


FCC CLASS B TEST LIMIT (3 METER) that the entire susceptibility test
is automated allows us to quickly
45
measure the susceptibility of any
fiber-optic module.
NO TEST DATA ABOVE 1 GHz WAS AVAILABLE

35
The BER pattern generator
drives a HFBR-510X/520X
25
transmitter that is located
outside the TEM cell. This
transmitter optically drives (via
15 a fiber-optic cable) a
HFBR-510X/520X receiver inside
the TEM cell. The transceiver
5 Rx inside the cell drives its
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
FREQUENCY OF RADIATION PEAKS, MHz neighboring Tx via the electrical
Figure 5. HFBR-5104/5203 (820 nm) radiated emissions at 125 Mbaud to Rx to Tx data line loopback
FCC B limits. connection on the test board.
test is slow and cumbersome. cell between the center and the The Tx inside the cell drives (via
0-5 We use a TEM cell. The TEM cell outer cell conducting planes. As another fiber-optic cable) a
is situated in our R&D lab, close long as the module and the test HFBR-510X/520X receiver
to all the BER measuring equip- board are not too large, the cell outside the TEM cell whose
ment. An automated test pro- will still generate a TEM wave outputs are connected to the
gram measures the BER and sets and the cell will still maintain its BER detector input. Thus a link
up the correct field strength and calibrated field strength to consisting of two transceivers is
frequency inside the TEM cell. output voltage correlation. Our bit error-rate tested.
The TEM cell is a large rectangu- cell is specified to 450 MHz,
lar metal cell that can be thought which is adequate for our suscep- The TEM cell test uses the same
of as an expanded coaxial tibility test because we see zero loopback test breadboard that is
waveguide. The voltage mea- susceptibility penalty above 350 used in the radiation test. The
sured at the output of the cell MHz for any of our HFBR-510X/ loopback board dc power is
corresponds to a certain electro- 520X transceivers. Above 450 brought in via a coaxial Vcc
magnetic field strength inside MHz, the TEM cell can resonate cable. The coaxial Vcc cable has
the cell. A module and test (i.e. standing electromagnetic a coiled section plus ferrites to
board can be placed inside the waves can form). Thus it cannot prevent noise pickup on the Vcc
17

QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

55 sensitivity at the left eye edge for


FCC CLASS B TEST LIMIT (3 METER) a 2(7) - 1 PRBS pattern is mea-
sured in exactly the same fashion
45
as is described in the conducted
noise tests. The sensitivity is
NO TEST DATA ABOVE 1 GHz WAS AVAILABLE
first measured with no field
35
present in the TEM cell. Then a
field is applied and the sensitiv-
25
ity is remeasured. The optical
dB change in the left eye edge
with 2(7) - 1 PRBS pattern and
15 1*10(-6) BER sensitivity, from
adding an electric field of a
known field strength and fre-
5 quency, is equal to the suscepti-
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
FREQUENCY OF RADIATION PEAKS, MHz bility penalty at that field
strength and frequency. The
Figure 6. HFBR-5104/5203 (820 nm) radiated emissions at 155 Mbaud to
FCC B limits. susceptibility penalty is therefore
calculated by subtracting the
sensitivity with the field present
QUASI PEAK RADIATION ELECTRIC FIELD STRENGTH IN dBµV/m

55
from the sensitivity with no field
FCC CLASS B TEST LIMIT (3 METER)
present. 10 V/m is the usual
45
field strength to use in suscepti-
bility tests. We also measure the
susceptibility at 3 V/m and 20 V/m
35
in to see how the susceptibility
varies over field strength.

25 4.2b Susceptibility
(Immunity) Testing Results
Figure 8 shows the susceptibility
15 results for a 1300 nm
NO TEST DATA BELOW 250 MHz WAS AVAILABLE
HFBR-510X/520X transceiver for
10.33 and 20.37 V/m field
5
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
strengths. The 10 V/m
FREQUENCY OF RADIATION PEAKS, MHz worst-case susceptibility is 0.05
Figure 7. HFBR-510X/520X (1300 nm) radiated emissions at 125 Mbaud dB, which is practically zero.
to FCC B limits using customer 3 x 6 inch multilayer FDDI PCB. You can see a slightly bigger
penalty of 0.13 dB at 20.37 V/m
cable. The coaxial Vcc cable is a The overall sensitivity in the which tells you that the test is
large antenna. It is important to susceptibility test, derived from the
indeed working. The 3.27 V/m
prevent it from picking up noise two fiber-optic transceivers in the susceptibility test shows less
and injecting that noise into the link, is determined by the errors penalty than does the 10.33 V/m
transceiver power supply be- produced by the loopback board Rx test. The 3 V/m test result was
cause we want to measure the which, using an optical attenuator, not printed because the plot was
susceptibility of the module and is run near the sensitivity optical too difficult to read. The data
not its Vcc noise rejection. Thus, input power level. There are no
was taken at 125 Mbaud for a
the susceptibility test measures errors produced by the regular 1300 nm transceiver. The
only the effects of the external breadboard Rx outside the TEM cell results do not change at 155
field on the module in its applica- because it runs at high optical input
Mbaud and are not dependent on
tion test board and therefore power levels due to the short fiber data rate. The 820 nm
includes any possible coupling or directly connecting the inside cell
HFBR-5104/5203 transceiver
interactions between the module Tx to the outside Rx.
susceptibility data was taken at
and its application test board.
155 Mbaud. The 820 nm suscep-
The 1*10(-6) bit error rate (BER)
18

0.15
withstand voltage. The ESD
withstand voltage is then used to
EMI INDUCED SENSITIVITY DEGRADATION IN dB (1 × 10-6 BER,

20.37 V/m determine the ESD class of the


component per the table in the
27-1 PRBS PATTERN, LEFT EDGE OF EYE)

0.10 MIL-STD-883D Method 3015.7


specification. In the
HFBR-510X/520X module the
data input and output pins are
0.05 the most sensitive to ESD.
These pins are therefore inter-
nally protected by ESD protec-
tion devices.
0
10.33 V/m
There is also a Japanese varia-
tion of the MIL-STD test which
models a machine body model
electrostatic discharge. The test
-0.05
0 50 100 150 200 250 300 350 400 450 is essentially similar to the
FREQUENCY OF THE TEM CELL INDUCED ELECTROMAGNETIC INTERFERENCE (EMI) FIELD, MHz MIL-STD specification, but
applies the discharge between
Figure 8. HFBR-510X/520X (1300 nm) susceptibility for ≈ 10 and ≈ 20 V/m fields. each pin and ground. The ESD
820 nm HFBR-5104/5203 susceptibility plots are not included here, but are as
good or better than the HFBR-510X/520X to within measurement noise
test circuit resistance, R, is zero
(max noise ≈ 0.05dB). ohms and the capacitance, C, is
200 pF. The low resistance
tibility is just as good as the even then probably very small, models the low resistance of a
1300 nm susceptibility. The disturbance in the HFBR-510X/ metal body. The specification is
actual data plot is not included 520X fiber-optic link. called EIAJ#1988.3.2B Version.2.
in this report because the result Machine Model.
is slightly better than the 1300 4.3a ESD Testing Procedure
nm result, but is, at the same The ESD component level tests Another ESD specification is
time, within the measurement are the most standardized of any based on the IEC 801-2 standard
noise of the 1300 nm result. of the component level EMC (see Reference (6)). This is
Both the 820 nm and 1300 nm tests. Many industry standard actually a box-level ESD test and
module susceptibility results are ESD tests were developed for specifies that the box product
so good that measurement noise integrated circuits (ICs) such as will not be “damaged” by an ESD
dominates in some of the plotted CMOS and TTL gates. One such that contacts it anywhere on the
data. (Maximum measurement standard is the MIL-STD-883D exposed outside areas of the
noise for the susceptibility test isMethod 3015.7 (see Reference product. Exactly what is meant
roughly 0.05 dB.) (5)). It classifies components by damage is left to the manufac-
into categories based on how turer and to the customer to
The negligible penalties to the much ESD voltage they can decide. We have defined “dam-
sensitivity for a 10-V/m external withstand. A human body model age” as permanent product
electromagnetic field give us ESD test circuit consisting of R = performance degradation. A
confidence that most applications 1500 ohms and C = 75 pF is temporary increase in BER
will see no performance degrada- charged up to a certain voltage during an ESD does not count as
tion in the fiber-optic link due to and is then directly discharged damage for this test. Our sus-
other nearby circuitry or to to various combinations of the ceptibility test, however, guaran-
external EMI sources (such as component pins. Five discharges tees good BER performance as
radio transmitters) that are to the pins are made. Next the long as the ESD does not cause
located outside the system module is tested for permanent an electrostatic discharge cur-
chassis. Only an extremely large performance degradation. The rent to flow directly through the
ESD has even a chance of creat- largest voltage at which no component and does not produce
ing a large enough field that permanent performance degra- electromagnetic fields above 10
could cause a noticeable, but dation is found is the ESD V/m in strength. In any case, as
19

soon as the ESD is over, the tions during handling should be worst case could cause only some
fiber-optic module immediately taken. During assembly ESD bit errors. Keeping in mind the
returns to normal operation. wrist straps and other modules’ good susceptibility
industry-standard ESD reduc- results, provides confidence that
The module was zapped on its tion techniques should be used to those bit errors will be the
exterior surface with an electro- ensure an ESD environment that absolute minimum possible for a
static discharge simulator wand is safe for Class 1 device han- fiber-optic module of this type. If
(zap). At first we zapped only dling. The HFBR-510X/520X good ESD design is used in the
the nose section (where the SC fiber-optic transceivers are computer system, it is probable
connectors are attached, about therefore shipped in a low-cost that only a very large ESD would
the first 0.5 inch (1.27 cm) or so). anti-static shipping tube to make even a noticeable differ-
We discharged to the top, bot- prevent ESDs during shipping ence in the fiber-optic link
tom, left, right and front of the and handling. The module did performance.
module nose. Since this did not pass at 1800 volts however, and
cause any permanent perfor- this is only 200 volts away from 4.4a Conducted Noise
mance degradation at 25 kV, the Class 2 MIL-STD ESD Testing Procedure
which was the limit of our test classification of 2000 volts. A known amount of noise is
equipment, we tried discharging Therefore the HFBR-510X/520X coupled onto the fiber-optic test
to any point on the top, left, right transceiver may not be as circuit Vcc. The degradation in
or front of the module. We used sensitive to ESD damage as most the receiver sensitivity due to
a EDS-200 Electrostatic Dis- MIL-STD Class 1 rated compo- this noise is then measured.
charge Simulator Wand. The nents. Sinusoidal noise signals of
wand simulates the human body different frequencies are used to
and has a capacitance of 300 pF The Japanese EIAJ#1988.3.2B check how the sensitivity degra-
and a resistance of 150 ohms. Version.2 Machine Model ESD dation varies over noise fre-
The module was self oscillating test showed that our module quency. 50 mV peak-to-peak
in an electrical and optical could withstand a 100 Volt level. (p-p) of sinusoidal noise is
loopback board. The status applied via an ac coupling bias
detect output drove an LED Once the module is installed in tee to a 1-ohm resistor, which is
which indicated whether the link its application board, it can directly connected to the Rx test
was up or not. After each set of withstand more ESD energy. board Vcc connection. The
ESD, the module was placed on The 25 kV zap test had no peak-to-peak noise level is
the manufacturing tester to problems. There was no perma- measured at the 1-ohm resistor
check for any module perfor- nent ESD damage to the module, on the side away from the
mance degradation. when in its application circuit, module Vcc connection. The
no matter where the zap oc- 1x10(-6) bit error rate (BER)
4.3b ESD Testing Results curred on the module surface. In sensitivity at the left eye edge for
The HFBR-510X/520X modules the loopback board test setup, a 2(7) - 1 PRBS pattern * is
sustained no damage with 5 the link monitor light might measured with no Vcc noise
discharges at 1800 Volts, using blink briefly during the ESD zap, present and with 50 mV p-p of
the MIL-STD human body model implying a momentary bit error Vcc noise present. The difference
test circuit to simulate an rate burst, but the light immedi- in sensitivity is the Vcc noise
electrostatic discharge that goes ately came back on once the sensitivity penalty. This value is
directly to the 1x9 module pins. discharge ended. Thus, the ESD recorded.
Above 1800 volts some perma- to the module could produce
nent module damage did occur. some bit errors but the module The noise sensitivity penalty is
This test was done according to recovers completely once the first tested with no external Vcc
MIL-STD-883D Method 3015.7 discharge ends (in a few millisec- filter present on the test bread-
using a 1.5 k ohm resistor and ond). Therefore a 25 kV dis- board. This tells us how well the
100 pF capacitor human body charge directly to a HFBR-510X/ module’s internal Vcc decoupling
model. Therefore, according to 520X transceiver module in- network can reject noise on its
MIL-STD-883D Method 3015.7, stalled in a computer system will own. Then a portion of the
this is a Class 1 device and cause no permanent damage and recommended data sheet power
appropriate Class 1 ESD precau- supply filter is added in. (See
20

Figure 11 of the HFBR-510X less than a 0.3 dB penalty for a tained a 0.1-µF capacitor at the
data sheet or Figure 7 of the 50 mV p-p noise signal in a real module pin, a 1-µH inductor in
HFBR-520X data sheet). The application circuit. series with the Vcc line, and a
external Vcc filter tested con- 0.1-µF capacitor on the other side
tained a 0.1-µF capacitor at the In a real application, if it turns of the inductor. (These compo-
module pin, a 1-µH inductor in out that very low frequency noise nents are labeled C1, L1, C3 in
series with the Vcc line, and a is present, and needs to be the data sheet). This filter does
0.1-µF capacitor on the other filtered, a 10-µF capacitor in not contain the 10-µF
side of the inductor. (These parallel with the 0.1-µF C1 at low-frequency filter capacitor,
components are labeled C1, L1 the Rx module Vcc pin would C4, present in Figure 11 (or 7)!
and C3 in the data sheets). This provide this additional Figure 12 shows that the Vcc
test filter does not contain the low-frequency filtering. We are noise problem areas are confined
10-µF, low-frequency capacitor fairly certain that this extra 10 to the frequencies where the
recommended on the data sheet µF will never be needed in the external Vcc filter resonates, at
(C4) because our ac coupling vast majority of the HFBR-510X/ around 440 kHz. Even this
network and the pulse generator 520X transceiver applications. worst-case point has less than a
cannot generate enough signal to (Therefore this extra 10-µF capaci- 1.4 dB sensitivity penalty.
drive the Vcc node to a 50 mV tor is not shown in the recom-
p-p level when the 10-µF capaci- mended data sheet power supply In a real application circuit, C4
tor is present. The effect on the Vcc filter.) Most applications, using will be present. This 10-µF
sensitivity with the 0.1-µF, 1-µH, the recommended data sheet Vcc capacitor will greatly attenuate
0.1-µF test filter in place is then power supply filtering, should never any low-frequency noise con-
measured. Finally, the effects of experience any problems in the ducted from the system Vcc
the filter if the entire recom- fiber-optic link operation due to V cc power supply circuitry. If the
mended data sheet Vcc filter, noise. resistance from the Vcc supply to
including the 10-µF capacitor, are the module Vcc filter is 0.2 ohm
estimated (but not measured). Figure 9 shows the Rx Vcc noise for example, the 10-µF capacitor
sensitivity penalty without the will form a filter with a 79 kHz
4.4b Conducted Noise external Vcc noise filter recom- bandwidth. At 440 kHz, the 50
Testing Results mended in Figure 11 of the mV noise, from the system Vcc
The sensitivity degradation to a HFBR-510X or Figure 7 of the power supply, will be attenuated
50 mV p-p noise signal at the Vcc HFBR-520X data sheet. The
connection was measured. In noise is conducted, via the 1-ohm * There are different sensitivity test
summary, the results are that resistor, directly into the module windows defined for each product in the
with no Vcc filter present on the Rx Vcc pin. The plot shows that product data sheets. These windows are
test board there is less than a 1 the transceiver module Rx derived from the link jitter allocations to
ensure that the Rx does not add more
dB penalty below 15 MHz and internal Vcc filtering network jitter to the overall link jitter than is
less than a 0.2 dB penalty above filters out almost all of the noise allowed by the link specification. The
15 MHz. With the external Vcc above 15 MHz on its own. sensitivity over the window is always
filter of a 0.1-µF capacitor at the Therefore, the Rx has less than a worse than the center of the eye
module pin, a 1-µH inductor in 0.2 dB Vcc noise sensitivity sensitivity. For Vcc noise and suscepti-
bility measurement sensitivity testing,
series with the Vcc line, and a penalty above 15 MHz. Figure the bit error rate detector clock is
0.1-µF capacitor on the other side 10 shows that less than a 1 dB aligned with the data eye so that the
of inductor, large amounts of penalty below 15 MHz is clock is at the left edge of the test
sensitivity degradation are present, even without any window in the data eye. Then the optical
confined to a small frequency external Vcc filter. input power is adjusted to get a 1x10(-6)
bit error rate. This optical input power
range around 440 kHz where the is then the left eye edge 1x10(-6) BER
filter resonates. Even in this Figure 11 shows that an external sensitivity level for the data pattern
small frequency range, the Vcc filter can really move any under test. See the notes in the data
penalty does not exceed 1.4 dB. noise problems that might be sheets (Reference (1) and (2)) for the
Estimates of the Vcc noise present down to much lower HFBR-510X/520X products that describe
the receiver section “Input Optical Power
performance using the real data frequencies. For this plot, the Minimum at Window Edge” specifica-
sheet Vcc filter, including the 10 external Vcc filter tested con- tions. (For example, note 20 for the
µF recommended capacitor, show HFBR-5103 Rx.)
21

to a 9 mV noise signal at the worst possible scenario has less penalty to a 50 mVp-p Vcc noise
module Vcc filter connection. An than a 1.4 dB penalty for a 50 signal. (Such a Vcc noise signal
educated guess indicates that the mV p-p noise signal. could be generated somewhere
sensitivity penalty will probably else in the customer’s system and
be less than 0.3 dB at 440 kHz. With good Vcc noise filtering on then conducted over to the
So the conclusion is that unfil- the Rx Vcc connection per the fiber-optic module Vcc via the
tered low-frequency noise can data sheet recommendation of Vcc power supply bus). Note
affect the receiver if it reaches figure 11 (or 7), the real system that it is impossible to perform
the module pin. Still, even the should have less than a 0.3 dB the Vcc noise immunity test with
C4 (10 µF) present because the
1.0 low ac impedance makes it
difficult to apply 50 mVp-p of
noise on Vcc with conventional
LEFT EYE EDGE 1 × 10-6 BER SENSITIVITY PENALTY IN dB FOR

0.8
sine wave generators and AC
coupling. Also, at this point, the
test does not really determine
Vcc NOISE CASE vs. NO Vcc NOISE CASE

what would happen in an actual


0.6 customer application due to the
uncertainty of what the Vcc line
impedance would be and how
0.4 much filtering the 10-µF capaci-
tor would really provide. The
general conclusion for now is
that the HFBR-510X/520X Vcc
0.2
noise rejection, in the real
application circuit, will be good
enough so that most applications
0 will not suffer any noticeable
degradations in the fiber-optic link
0 50 100 150 200 250 300
Vcc NOISE FREQUENCY, MHz performance due to Vcc noise.
Figure 9. HFBR-510X/520X Vcc noise performance with no external Vcc filter.
5.0 Conclusions
1.0
It is no surprise that the
HFBR-510X/520X transceiver
modules have excellent electro-
LEFT EYE EDGE 1 × 10-6 BER SENSITIVITY PENALTY IN dB FOR

0.8 magnetic compatibility because it


was taken into account early in
Vcc NOISE CASE vs. NO Vcc NOISE CASE

their design. Over the years, we


have learned a lot about EMC
0.6
and made a great deal of im-
provements in the design of
fiber-optic modules to satisfy our
0.4 customers' needs to meet global
EMC requirements. The inte-
grated circuits used in the
0.2
modules are designed to reject
Vcc noise. The circuits are also
designed to be as differential as
is possible in order to help reduce
0 Vcc noise generation and to help
0 5 10 15 20 25 30 35 40 45 50
improve the Vcc noise and
Vcc NOISE FREQUENCY, MHz susceptibility noise rejection.
Figure 10. HFBR-510X/520X Vcc noise performance with no external Vcc filter The internal edge rates inside
0 to 50 MHz.
22

1.4
high-frequency layout techniques
that reduce loop sizes to improve
LEFT EYE EDGE 1 × 10-6 BER SENSITIVITY PENALTY IN dB FOR

1.2 emissions, susceptibility and Vcc


noise.
Vcc NOISE CASE vs. NO Vcc NOISE CASE

1.0
All these improvements were
made while keeping the module
0.8 cost low. The cost of the EMC
improvements is a small percent-
age of the overall module cost
0.6 and we think customers will find
it well worth it when they
0.4
consider the money and time it
saves them in their final product
design and manufacturing cost.
0.2 The HFBR-510X/520X trans-
ceiver modules will make the
0
final product easier to meet EMC
compliance, will make it less
50 150 250
0 100
Vcc NOISE FREQUENCY, MHz
200 300
likely for the final product to
Figure 11. HFBR-510X/520X V cc noise performance with 0.1 µF, 1 µH,
experience strange intermittent
0.1 µF external Vcc filter (C1, L1, C3 in the data sheet).
internal EMC-related perfor-
mance problems and, if the
1.4 HFBR-510X/520X transceiver
module EMC performance is
taken advantage of, will allow
1.2
cheaper lower-cost shielding to
LEFT EYE EDGE 1 × 10-6 BER SENSITIVITY PENALTY IN dB FOR

be used in the final product.


1.0
The HFBR-510X/520X trans-
Vcc NOISE CASE vs. NO Vcc NOISE CASE

ceiver module EMC performance


0.8 is summarized below.

The module’s radiated emissions


0.6
typically passes worldwide B
limits (FCC B, CISPR 22B, EN
0.4
55022, and VCCI Class 2) by
more than 10 dB. One unit in a
computer system will not cause
0.2 this system to fail the worldwide
radiated emissions limits, for
either the home or office usage
0 environments, no matter how
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 poor the shielding is. The
Vcc NOISE FREQUENCY, MHz
excellent module emissions level
allows the best attempt at using
Figure 12. HFBR-510X/520X Vcc noise performance with 0.1 µF, 1 µH, 0.1 µF
a large number of modules in
external Vcc filter 0 to 5 MHz (C1, L1, C3 in the data sheet).
concentrator applications while
still allowing the concentrators to
the ICs have been carefully used to reduce the emissions pass radiated emission limits.
limited to help reduce the from the transmitter and to
radiated emissions. Special improve the susceptibility of the The susceptibility is basically
module packaging techniques, receiver. The modular printed zero for 10 V/m fields. Because
including internal shielding, are circuit board uses good of the module’s high immunity,
23

the customers need not worry current through the module can Electrotechnique Internationale IEC
about the effects of nearby cause some bit errors but the International Standard 801-3. Electro-
magnetic Compatibility For
circuits on the receiver. Fields module recovers very quickly. Industrial-Process Measurement and
generated external to the com- Control Equipment. Part 3: Radiated
puter system are also not a In the real application circuit, Electromagnetic Field Requirements}
worry. Only very large ESD with the data sheet recom- Third Impression 1992. International
events could generate a 10 V/m mended power supply filter, 50 Electrotechnical Commission.
field, so the concern about ESD mVp-p of Vcc noise should cause
zaps causing bit errors is mini- no more than a 0.3 dB sensitivity
mized. This unit is suitable for penalty, no matter what the Vcc
use in Class 3 severe electromag- noise frequency is. Most Vcc
netic radiated field environments noise frequencies will cause zero
as described in the IEC 801-3 penalty. In most applications
specification. there should be no noticeable
effect on the fiber-optic link
The crosstalk from the transmit- performance due to Vcc noise.
ter to the receiver in the trans-
ceiver module is virtually zero. References
Thus the operation of the Tx in
the transceiver will not affect the [1] Hewlett Packard Optical Communica-
operation of its neighboring Rx tions Division. FDDI and 100 Mbps
ATM Transceivers in Low Cost 1x9
in the same transceiver under Package Style. Technical Data.
any circumstances. HFBR-5103 1300 nm 2000 m.
HFBR-5104 800 nm 150 m. HFBR-5105
The ESD test is conducted per 1300 nm 500 m. 1994. HP OCD.
the MIL-STD-883D Method
[2] Hewlett Packard Optical Communica-
3015.7 specification. The tions Division. ATM Multimode Fiber
HFBR-510X/520X transceiver Transceivers For SONET OC-3/SDH
modules withstand 1800 V STM-1 in Low Cost 1x9 Package Style.
human-body model electrostatic Technical Data. HFBR-5203 800 nm 150
discharge to any combination of m. HFBR-5204 1300 nm 500 m.
HFBR-5205 1300 nm 2 km. 1994.
pins with no permanent damage. HP OCD.
The modules are classified as
MIL-STD Class 1 ESD compo- [3] Henry W. Ott. Noise Reduction
nents, but are close to the 2000 Techniques in Electronic Systems 2nd
Volt Class 2 minimum limit. Edition 1988. John Wiley & Sons.

[4] Various authors. Test & Design


These transceivers also with- Magazine. Argus Business.
stand a 100 Volt level to the
Japanese EIAJ#1988.3.2B [5] Department of Defense. United
Version.2 Machine Model ESD States of America. Military Standard.
Test Methods and Procedures For
test. Microelectronics. MIL-STD-883D
Method 3015.7 1991. Rome Laboratory
When the transceiver is installed AFSC.
in the application circuit, the
module withstands a 25 kV ESD [6] Bureau Central de La Commisscion
Electrotechnique Internationale IEC
zap to anywhere on the module International Standard 801-2. Electro-
with no permanent damage. It magnetic Compatibility For
should not be damaged by any 25 Industrial-Process Measurement and
kV human body zap in any Control Equipment. Part 2 Electrostatic
computer system application. Discharge Requirements} Second
Impression 1987. International
This is a variation of the IEC Electrotechnical Commission.
801-2 test. A rare ESD directly [7] Bureau Central de La Commisscion
to the module that conducts
hH

For more information call:


United States*
Europe*
Far East/Australasia: (65) 290-6305
Canada: (416) 206-4725
Japan: (813) 3331-6111
* Call your local HP sales office listed
in your telephone directory. Ask for a
Components representative.
Data Subject to Change
Copyright © 1994 Hewlett-Packard Co.