You are on page 1of 4

'SYSTEMS

OSHA/NFPA Units listed ln this brochure meet or exceed the NFPA (101) Life Safety Code and OSHA Section 1 910.35 or 1 91 0.37 for means of Egress.

OSHR EGRESS

EMERGENCY EXITS
(SELF CONTAINED)

MEETS OSHA REQUIREMENIS FOF? EGRESS IDENTIFICATION UL LISTED

UNIYERSRL EXIT
SERIES
MEETS NFPA STATE AND LOCAL 1O1 FIRE AND BUILDING CODE UL LISTED

the modern "slide-out component" principle that allows extreme ease of wiring and maintenance. The units meet OSHA requirements - NFPA and both 120 vblt and 277 and are designed for applivoll clrcuitryi rmergeniy lcation on 7 units operate a minimum of 90 minutes (code requirem'ent) and feature the flashing principle (actual operating time in emergency mode is in excess of 2 hours). A new compact sealed 6 volt nickel cadmium battery is used having a 5 year guarantee. The exit units come complete with lamps and offer a ten year lamp life. Emergency bulbs are also furnished and are 7 volt DC bayonet type to maintain desired light level on tace of Exits.

A completely new compact, solid-state, Emergency Exit series. These units are designed to minimize the overall height of Emergency Exits with a compact power pack using

and will maintain desired light level on face in emergency fJashing mode. Code requirement is 90 minutes, actual battery service length is in excess ol 2 hours with auto cut-ofl to prevenl completely discharglng battery. Unlversal canopy is supplied with Exit for end or top mounting of unit. KO is provided for stem mounling. Power pack is reversible so that test switch and ready light are always visible. Ready light is long life solid-slate LED type. Power Pack is tapped for 120 ot 277 voll application. (For conversion ol existing 277V. Exits consult factory).
LJse

#EX-2 Conversion Kit for double tace.

EMERGENCY EXITS
Self contained Emergency unit-Single Face-complete with lamps, battery
EXM-120-277

FEATURES:

. . Solid state circuit module with pluq in connections. . Test switch provided and a ready light to show that unit

Emergency Power Pack teatures solid state components mounted on slide-out panel. Completely self contained with all lamps and battery pack fu rnished. is charged and in readiness condition. Exit is universal type equipped for any single iace
comb ination.

ACCESSORIES
Conversion kit for Reverse Color Double Face Cat. No, EX-2

.
.

Power-Pack can be used on existing Benjamin EXO-120


Exits.

to

EXM-12'1.

SPECIFICATIONS:
Unit is satin finish, anodjzed extruded aluminum with matching stencil and acrylic Jace, complete with arrow panels. Face is red or green Acryllc/Fiberglas letter panels with a distortion factor over 233'C. Letters are code size 6" high wlth %" wide stroke. Lamps furnished on 120 V. 60 cycle unit are 40T10/1F with rectifier Ior 10 year lamp lite. Lamps furnished for Emergency are 7 V. DC

POWER PACK ONLY


#EXM-1 Emergency powerpack may be
used

with

Un

units listed below in eiiher 120 volt or 277 volt applications.

iversal +EXO-1 20

NFPA and OSHA requirements, plus various State and city bu ild ing codes -all in one economical package. As

The new Universai Exit Series was engineered specifically to meet

a result the EXO-'I20 has become


the most popuiar stock and speciftcation exit series available.

grade with temp. d stortion factor 264 pSt-233oc Self extlngulshing. Lamps furnished are (2) 40T10/1Fon 120V) utiliz ng encapsulated rectifiers for 10 yr. lamp lite.The 277V untt uses an isolatron transformer and iwo (2J 7 volt AC-DC larnps with 10,000 hr. lif e.

FEATURES

.
.

SINGLE FACE UNIVERSAL EXIT


Uf t w th Red or Creen etlers of Acrylic face Stenc i. Arrows, Arrow
b
a n

Directional arrows and panels slide in extruded tracks for simplicity One screw allows accessibility for mou nting and chanqinq components.

Jis, and

cafopy

S ng e Face

tjiit

(Same as above)

. Cac bp pendanr. wdll or


3%tt or 4" ouflet box.
S

cei'ing

n'rounted with extruded canopy to

REVERSE C0L0R Llfiveisal Exit (White letters on Red or Green backgro!fd) REVERSE C0L0R (Same as above)

txo t2r

277u

PECIFICATION S Unit is Satin etched and Anodized Extruded Aluminum with matching stencrl face, blanks arrows and ca opy. Special Red or Green Acrylic/ Fiberglass letter panels are FR

ACCESSOBIES
Description
l]onversion I for DoLb e Face lln t Reverse Color Cofvcrsiof Kil for
K

Cat. No.

Doub e Face Canopy 0n y

CONVERSION KIT
REI!1OTE POWER CONVTRSION KIT TO ADAPT THE TXO 120 EIIT TO EITHTR AC OR DC EIllERGENCY UST

Ufit snaps into extrr.rded tracks inslde top o1EX0 120 Furn shed ess arnps k I uses two (2) bayonet type amps for 6 12 or 24V DC The AC unit !ses two-(2) 40Tl0r lF arnps

COM PLETE KITS

EMERGENCY POIUER FRILURE

RLRRm
FEATURES

EXIT,*,,"on,a

ned)

IN CASE OF POWER FAILURE UNIT ACTIVATES WITH INTERMITTENT SOUND ALARM AND FLASHING LIGHT

. All extruded

aluminum satin finish construction

o Completely prewired with solid-state plug-in

.
.

module and power pack External test switch and ready light Exit is universal type, red or green

POWEH FAILURE ALARIVI* (sell contained) (Fused) Sell Contarned Power Far ure Exit Alarrn LUnive.sal Typel Sarae as above only Reverse colors iwhite on Green or Red Face) *ldentification DecaL may be affixed at instal ers option.

ACCESSORIES
Cat. No.

This unique power-failure unit warns of power iailure by both sight (flashing lamps) and sound (intermittent vibrating type signal). ldeal ior use in situations where attention should be drawn to Exits immediately
LJnit meets NFPA and OSHA requirements

in case oi power failure.

ior Egress lighting.

Mounting Canopy (noi furnlshed with unit) Conversion Kit for Double Face Unit Reverse Color Conversion Kit for Double Face Replacement Battery Pack Replacement So id-State Control

EXA-3

EX-2 EX.4
EXA-15 EXA-21

UL LISTED

EMERGENCY FIRE

RLRRm

EXlTo.,,

EI
S

fr
life lamps #161.

WHEN FIRE OCCURS UNIT ACTIVATES WITH INTERMITTENT SOUND ALARM AND FLASHING LIGHT Activated by heat sensors this evacuaiion unit sounds a 90 DB {at 10') alarm and flashing light. Unit has a supervised sensing circuit for 10,000 feet of 2-22 wire. A line trou ble ind icator lig hi (flashing yellow) and a test switch are external for ease in checking. Unjt can be wired independently, automatic or as a supervised system. Perfect for use in nursing homes, hotels, motels, schools and hospitals. EMERGENCY FIRE ALARM EXIT* (self contained)
Self Conta ned Fire Alarm Ex t Sarne as above only reverse colors (while letters on Red or Green Face * dentificat on Decal may be affixed at insta lers option
EXA-120-EAF
E X

"on,a

ned)

A-121-EA F

General specs same as Emergency exit, other com-

PECIFICATION S

ACCESSORIES
Description Mounting Canopy (not furnished with unit) Conversion Krt for Double Face Jnll Reverse Color Conversion Klt for Double Face
Cat. No.
EXA-3

special for this un it only. Lamps furnished are four {4)

ponents including solid-state circuitry module are 14V DC Wedge Base Long

cE

EX-2
EX-4 EXA-15 EXA-21

Signal is lVodutone (90D8 at 10'). Battery pack is (2) Gell Cell GC-610, 1.5 AH for 72 hour standby.

BFNIITIITN EINCTRIC MFG CA

4D7352

Printed in USA